Instruction/ maintenance manual of the product 3115 Powerware
Go to page of 32
Power w are ® 3115 User ’s Guide 30 0-650 V A www . powerware.com 02/15/01.
Po werwar e is a r egist er ed tr ademark of Po werwar e Corpo rat ion . Cop yright 1999 Powerwa r e C orporation, Raleig h, N C. All rights r ese rved. No part of this document may be reproduced in an y way wit hou t the expr ess wri tt en appr oval of Po werwar e Corpo rat ion .
Class B Statement for FCC and ICES NOTE Th is equ ipmen t has been t ested and fou nd to co mply wi th t he limit s for a Class B devi ce pursu ant to P art 15 of FCC R ules. Thes e limits ar e de signed to provide reas onable protection aga inst ha rmful interferenc e when this equipme nt is oper ated i n a r esiden tial env ir onmen t.
Special Symbols The follow ing ar e exam ples of sym bols us ed on t he UPS to alert you to import ant inf ormation: Risk of Electr ic Shock Do Not Open Cover C C C CA A A AU U U UT T T TI I I IO O O .
i Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T ABLE OF C ONTENTS 1 Powerwar e 3115 – One of the Best! 1 .................................. 2 Installation 3 ..................................................... Ins pecti ng the Equipment 3 .
T a ble of Conten ts ii Powerw are ® 3115 U ser’s Gui de www .powerw are.c om.
1 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 1 P OWERWARE 3115 – ONE OF THE BEST! The P owerware 3115 un interr uptibl e power sys tem (UPS) protects your sensitive e lect r o nic equipme nt fr o m three basic p owe r p r o blems: power fai lur es, power s ags , and power s ur ges.
Pow erw ar e 3115 – ONE OF T HE BEST ! 2 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om 650 VA 300 VA and 420 VA Figure 1. Powerware 3115.
3 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 2 I NST ALLA TION This se ction e xpla ins: Equ ipment i nspecti on Safet y pr ecaut ion s UPS in stallation UP S r ear panel s Insp.
In stallat ion 4 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om WAR NING This UPS contai ns its own energy s ource (batteri es). The output rec eptacl es may carry live vol tage even when the U PS is not c onnected to an AC suppl y . Do not rem ove or unplug the i nput cord when the UPS is turned on.
In stallat ion 5 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om 5. Sta rt the U PS by pres sing the button as shown i n Figu re 2. The Powe r On ind icat or illumina tes i ndica ting tha t po wer is avai labl e fr om th e rear r eceptacles .
In stallat ion 6 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om UPS Rear Panels Thi s section sh ows the r ear panels of all Power ware 3115 models. Power C ord with 5-15 Plug Com munication Port DIP S witches T w o 5 - 15 Output Receptacl es 10A, R esettable Ci rcuit Breaker Si te Wiring Fault Indicator Figure 3.
In stallat ion 7 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om 10A, IEC-320 I nput Connector with Fuse Com munication Port DIP S witches T w o IEC- 320 Output Receptacl es Figure 5. PW 3 300i and PW3 420i Rear Panel Com munication Port 10A, I EC-320, Input C onnector with Fuse DIP S witches Four IEC- 320 Output Receptacl es Figure 6.
In stallat ion 8 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om.
9 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 3 O PERA TION AND C ONFIGURA TION Th is sect ion cov ers: T urning t he UPS o n and off Starting th e UPS on batte ry Standby mode H.
Operat ion and C onfigura tion 10 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Standby Mode When the UPS is turne d off and p lugged int o a wall outle t or othe r power s our ce, the UP S is in S tan dby mode.
Operat ion and C onfigura tion 11 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T able 1. DIP S witch Se ttings 120V M odels D I PS w i t c h1 D I PS w i t c h2 D I PS w i t c h3 D I PS w i.
Operat ion and C onfigura tion 12 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Wh en the commu ni cation cabl e is in stal led, power m anag ement sof twar e can exch ange dat a wit h th e UPS . Th e soft war e polls th e UPS for detailed infor mation on the statu s of th e p ower envir onment.
13 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 4 UPS M AINTENANCE This sec tion ex plains how t o: Ca r e f or the UPS and ba tte ries Replace the batte r ies T e s t new batte r.
UPS Mai ntenance 14 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Replacing Batteries Th e fol low in g st eps expl ain h ow to r eplace th e batter ies.
UPS Mai ntenance 15 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Bla ck ( –) Red (+ ) Figure 9. Replacing Batteries (300 V A and 420 V A models).
UPS Mai ntenance 16 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Bla ck ( –) Red (+ ) Figure 10. Replacing Batteries (650 V A models).
UPS Mai ntenance 17 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T esting New Batteries NOTE It i s recom mended that the UPS charge for 24 hours before tes ting the new batteries . Press and ho ld the button for th ree seconds to initi ate the battery test.
UPS Mai ntenance 18 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om.
19 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 5 S PECIFICA TIONS Th is s ection pr ovi des th e foll owin g specif icati ons fo r th e Powerwar e 3115 models: El ectri cal inpu t and outpu t Battery W e ights a nd dim ensions Environm enta l and sa fet y T able 3.
Sp ecification s 20 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T abl e 5. Electrical O utput 120V M odels 230V M odels Power L evel s (r ated at nomi nal input s) PW3 300: 300 VA , 180W .
Sp ecification s 21 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T abl e 7. W eight s and Dimensions 120V M odels 230V M odels UPS Dimens ions (HxW xD) PW3 300: 155 x 86 x 371 mm (6.1 x 3.4 x 14.6 in ) PW3 420: 155 x 86 x 371 mm (6.1 x 3.4 x 14.
Sp ecification s 22 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om.
23 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om CHAPTE R 6 T ROUBLESHOOTING This se ction e xpla ins: Site wir ing fault on 120V mode l s UPS a larms a nd cond itions How to silenc e a n a.
T r oubles hooting 24 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om T abl e 9. T roubl eshooting Alar m or Condit ion Pos si ble Cause Acti on The Power O n indicator is not on; the U PS does not The line cord i s not connected or not plugged in.
T r oubles hooting 25 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om Acti on Poss ible Caus e Alar m or Condit ion The UPS beeps 1 tim e every 0.5 second. Power requirem ents exceed UPS capacity (overload is greater than 120%) or the l oad is defective.
T r oubles hooting 26 Powerw are ® 3115 U ser’s Gui de www .powerw are.c om.
An important point after buying a device Powerware 3115 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Powerware 3115 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Powerware 3115 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Powerware 3115 you will learn all the available features of the product, as well as information on its operation. The information that you get Powerware 3115 will certainly help you make a decision on the purchase.
If you already are a holder of Powerware 3115, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Powerware 3115.
However, one of the most important roles played by the user manual is to help in solving problems with Powerware 3115. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Powerware 3115 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center