E. Idle Control Switch The Idle Control circuit is designed to extend engine life and improve fuel usage by slowing the engine down to approximately 2000 RPM in a “No Load” condition. The noise is also greatly reduced during this condition.
* 22 HP Subaru OHV engine * Cast-iron cylinder sleeve * Low oil sensor * Receptacles on control panel * Electric Start * Idle control * CordKeeper™ * 8 gallon plastic fuel tank * Spark arrester * Portability Kit
When power is required from the generator an electronic control module automatically senses current flow in the electrical outlet and allows the engine to return to full speed or standard operating condition. Likewise, when the load is removed, the generator will automatically return to the idle condition after a 4-5 second delay.
A convenient switch is mounted in the control panel for easy access and will disable the Idle Control circuitry when in the off position.
A. 120 Volt GFCI Receptacle Ground Fault Circuit Interrupter duplex receptacle is rated so that a total of 20 amps may be drawn regardless of whether both halves or just one receptacle is used. This receptacle may be used along with other receptacles provided the generator is not overloaded and total power drawn is kept within nameplate ratings. Ground Fault Circuit Interrupter (Conforms to U.L 943, Class A and NEC requirements) This device protects you against hazardous electrical shock that may be caused if your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is “ live “ through faulty mechanism, damp or worn insulation, etc.

F. CordKeeper™ Restraint The CordKeeper™ restraint is a unique feature used to prevent plugs from being pulled out of the receptacles.
Refer to the appropriate diagram for proper connection of power cord wires to the plug terminals.
B. 120 Volt, 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps from this receptacle. If other receptacles are used at the same time, total power used must be kept within nameplate ratings.
C. 120/240 Volt Heavy Duty Receptacle This receptacle is rated at 50 amps but the current must be limited to the nameplate rating. If this receptacle is used along with the 120 volt receptacles, the total load drawn must not exceed the nameplate ratings.
D. Circuit Breakers The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.
120 Volt 30 Amp Plug

120/240 Volt Heavy Duty Plug

The generator is equipped with electric start. An “Off-On- Start” rotary key switch is provided on the recoil end panel. All necessary wiring is provided. The battery is provided. See engine manual for wiring diagram (3A Charge Coil), and additional information.
The charging system of the unit is supplied by the starter/alternator of the engine. 12 volts DC is constantly charging the battery when the unit is running . Disconnecting the battery will stop the charging of the battery.
Connect the red 8 ga. battery lead to the positive (+) battery post and the black 8 ga. battery to the negative (-) battery post with the bolts and nuts provided.
Before charging a storage battery, check the electrolyte fluid level in all the cells. (Sealed batteries do not require checking). Add distilled water to each cell if necessary, to bring the level back up to the manufacturer’s required level.

Item Description Qty. A. *Bolt, 1/4-20 X 8” 2 B. *Washer 1/4 2 C. *Spacer 2 D. Hold Down bar (P/N 0036525.02) 1 E. *Nyloc nut, 1/4-20 2
Powermate Corporation recommends a 12 V battery with at least 235 cranking amps, Model U1L, Lawn and Garden Battery.
* These are standard parts available at your local hardware store.

TOOLS REQUIRED: Hammer, 1/2” wrench, ratchet with a 1/2” socket, and wood blocks. Refer to the drawing for proper alignment of Foot bracket and Wheel brackets. Refer to the parts list on pages 15 and 16.
Wheel Bracket & Wheel Installation
1. Block up end of generator, about 8” high, opposite the fuel tank cap to install wheels and wheel bracket assy. 2. Add 5/16 washer (item 29) to the 1 3/4” bolts (item 71) and insert bolts/washers through the holes located in the base pan of the carrier. 3. Place the wheel bracket (item 65) through the bolts and add a 5/16 nyloc nut (item 27) and tighten securely. (On the bottom side of the pan in-between the holes will be a 1” square brace, the wheel bracket will set on this brace). 4. Add wheel spacer (item 70) to the axle. 5. Slide the wheel (item 64) onto the axle until it is snug against the spacer. The wheel is on correctly if there is approximately a 1/2” gap between the carrier tubing and the side of the wheel. If it is less then 1/2” from the carrier, turn the wheel over and reinstall. Align the wheels parallel to the carrier tubing and tighten nuts securly. To align correctly, the bolts holding the wheel bracket may have to be loosened. 6. With a hammer, add the plastic cap (item 69) on end of axle. 7. Repeat above instructions for the remaining wheel.



Foot bracket Installation · Locking Handle