EN
Powermate logo
Official user manual

Powermate PM0557501.01

12 pages·952 KB·Portable Generator·PDF·ENDEFRITNLJA
Powermate PM0557501.01
Table of Contents 10 sections PM0557501.01 Insert Additif Adición · ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO · www.colemanpowermate.com LFL 05/03 0062225 · MAJOR GENERATOR FEATURES ELECTRIC START · … ShowHide
Page 1 of the Powermate PM0557501.01 user manual — www.colemanpowermate.com LFL 05/03 0062225
Page 1 · click to enlarge
Page 1

PM0557501.01 Insert Additif Adición

Powermate PM0557501.01 — PM0557501.01 Insert Additif Adición diagram (page 1)
Fig. 1 · PM0557501.01 Insert Additif Adición

ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO

Powermate PM0557501.01 — ELECTRIC GENERATOR GROUPE ELECTROGENE GENERADOR ELECTRICO diagram (page 1)
Fig. 2

www.colemanpowermate.com LFL 05/03 0062225

Page 2 of the Powermate PM0557501.01 user manual — 2 English
Page 2 · click to enlarge
Page 2

MAJOR GENERATOR FEATURES ELECTRIC START

* 16 HP Tecumseh OHV engine

An “Off-On-Start” rotary key switch (D) is provided on the control panel. All necessary wiring is provided. The battery is not included - must be purchased separately.

* Cast-iron cylinder sleeve

* Low oil sensor

Coleman Powermate recommends a 12 v battery with at least 235 cranking amps. Model U1L, Lawn and Garden Battery. Place the battery in the position provided. Then place the bolts through the loops on the Hold-Down bracket. Place the assembly over the battery and place the bolts through the holes on the battery pan and tighten down the Hold-Down assembly with the 1/4-20 nuts provided. Spacers may be added depending on the battery height.

* Receptacles on control panel

* 7 gallon plastic fuel tank

CONTROL PANEL

A. 120 V, 20 Ampere Duplex Receptacle This duplex is split so that 20 amps of current may be drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings. These receptacles may be used along with the twistlock receptacle provided the generator is not overloaded.

B. 120/240 V, 30 Ampere Twistlock Receptacle A maximum of 30 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.

Connect the red 8 ga. battery lead to the positive battery post and the black 8 ga. battery lead to the negative battery post with the bolts and nuts provided (Items F, G, and H).

The engine contains an internal battery charger which is connected to the positive (Red) battery lead. Battery charging will occur when the engine is running.

C. Circuit Breakers The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

BATTERY INSTALLATION

Powermate PM0557501.01 — BATTERY INSTALLATION diagram (page 2)
Fig. 3

2 English

Battery Installation · * Electric start · * Portability Kit

Page 3 of the Powermate PM0557501.01 user manual — 3 English
Page 3 · click to enlarge
Page 3

BATTERY KIT PARTS LIST LIMITED WARRANTY (NOT VALID IN MEXICO)

Item Description Qty. A. * Bolt, 1/4-20 x 8” 2 B. * Washer 1/4 2 C. Hold Down bar (P/N 0036525.02) 1 D. * Nyloc nut, 1/4-20 2 E. * Spacer (optional) 2 F. * Bolt, 1/4-20 x .75” 2 G. * Wing nut, 1/4-20 2 H. * Washer, lock 1/4 2

This product is warranted by Coleman Powermate, Inc. to the original retail consumer against defects in material and workmanship for a period of two years from the date of retail purchase and is not transferable. This two year warranty applies only to products used in consumer applications. If this generator is used in a commercial application, then the period of warranty coverage is limited to one (1) year from the date of purchase.

* These are standard parts available at your local hardware store.

Please complete and return the enclosed Customer Information Card so that we can reach you in the unlikely event a safety recall is needed. Return of this card is not required to validate this warranty.

HANDLE INSTALLATION

WHAT IS COVERED: Replacement parts and labor.

TOOLS REQUIRED: Two 7/16” wrenches or and adjustable wrench (cresent). Refer to the parts list and drawing on pages 8 and 9.

WHAT IS NOT COVERED: Transportation charges to Coleman Powermate, Inc. for defective products. Transportation charges to consumer for repaired products. Brushes, fuses, rubber feet, and receptacles. Damages caused by abuse, accident, improper repair, or failure to perform normal maintenance. Power units or engines which are covered exclusively by the warranties of their manufacturer. Sales outside of the United States or Canada. Any other expense including consequential damages, incidental damages, or incidental expenses, including damage to property. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

1. Slide the reduced ends of the handle (item 36) into the upright tubes of the base as shown in the diagram. 2. Install the 1/4” x 2.00” bolts (item 31) through the tubes from the outside. 3. Thread the 1/4” washers (item 26) and the 1/4” nyloc nuts (item 27) onto the bolts and tighten. NOTE: Do not over tighten.

IMPLIED WARRANTIES: Any implied warranties, including the Implied Warranties of Merchantability and Fitness For A Particular Purpose, are limited in duration to one (1) year from the date of retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

HOW TO OBTAIN WARRANTY PERFORMANCE: Replacement parts and service are available from Coleman Powermate, Inc. Service Centers. Locate your nearest Service Center by calling TOLL FREE 1-800-445-1805. In the unlikely event a Service Center can not be located you may call Coleman Powermate, Inc. for a return authorization number. Any unit returned WITHOUT an authorization number will be refused.

To the extent any provision of this warranty is prohibited by federal, state, or municipal law, and cannot be preempted, it shall not be applicable. This warranty gives you specific rights, and you may also have other rights which vary from state to state.

3 English

Ask about the Powermate PM0557501.01

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Powermate PM0557501.01

Be the first to ask — other owners or our team will answer.

Original document

Powermate PM0557501.01 manual PDF

12 pages·952 KB·Portable Generator·PDF