hazardous situation which, if not avoided, WILL result in death or
hazardous situation which, if not
avoided, may result in minor or
which, if not avoided, could result in death or serious injury.
moderate personal injury, or
serious injury.
property damage.
12.Your generator should never be operated under these conditions: a. Uncontrolled change in engine speed. b. Electrical output loss. c. Overheating in connected equipment. d. Sparking. e. Damaged receptacles. f. Engine misfire. g. Excessive vibration. h. Flame or smoke. i. Enclosed compartment. j. Rain, snow or inclement weather. Do not let
the unit get wet when operating.
13.Check the fuel system periodically for leaks or signs of deterioration such as chafed or spongy hose, loose or missing clamps, or damaged tank or cap. All defects should be corrected before operation.
14.The generator should be operated, serviced, and refueled only under the following conditions: a. Start and run the generator outdoors. Do
not run the generator in an enclosed area, even if doors or windows are open; avoid areas where vapors may be trapped, such as pits, garages, cellars, excavations and boat bilges. DANGER - CARBON MONOXIDE HAZARD: The engine exhaust contains carbon monoxide, a poisonous, odorless, invisible gas which, if breathed, may cause death or serious personal injury. If you start to feel sick, dizzy or weak while using the generator, shut it off and get to fresh air right away; you may have carbon monoxide poisoning. b.Good ventilation for cooling. Air flow and
10.Extension cords, power cords, and all electrical equipment must be in good condition. Never operate electrical equipment with damaged or defective cords.
temperatures are important for air cooled units. Temperatures should not exceed 104º F ambient (40º C). c. Refuel the generator in a well lighted area.
Avoid fuel spills and never refuel while the generator is running. Allow engine to cool for two minutes prior to refueling.
English Customer Hotline 1-800-445-1805 3



To avoid backfeeding into utility systems, isolation of the residence electrical system is required.

Before temporary connection of the generator to the residence electrical system, turn off the main service/disconnect.
CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.
If your generator is to be used as a stand-by power source in case of utility power failure, it should be installed by a registered electrician and in compliance with all applicable local electrical codes.
Proper use requires that a double throw transfer switch be installed by a licensed qualified electrician so that the building's electrical circuits may be safely switched between utility power and the generator's output, thereby preventing backfeed into the power utility's electrical system.
A power line conditioner should be used when running one or more of the following solid state items:

Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment
To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system. California law requires isolation of the residence electrical system before connecting a generator to residence electrical systems. Temporary connection not recommended due to backfeeding.
Other solid state equipment may require a power line conditioner. For more information, contact our Customer Service Department at 1-800-445-1805.
Always follow local codes and regulations that apply to the installation of any item that concerns this product.
To avoid possible personal injury or equipment damage, a registered electrician or an authorized service representative should perform installation and all service. Under no circumstances should an unqualified person attempt to wire into a utility circuit.
5 English Customer Hotline 1-800-445-1805

DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil. Your generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.
Some jobsites and local codes may require GFCI protection for personnel before operation of your generator. If your generator is not already equipped with a GFCI receptacle, GFCI In-line cord sets may be purchased from your local electrical supply store or home builder appliance store.
Fill the engine with oil according to the operator manual. For units with a dipstick, fill oil to the proper level. Units without a dipstick should be filled to the top of the opening of the oil fill.
These cord sets are available in various plug and amperage configurations. (Make sure your generator is properly Grounded.)

The National Electric Code requires that this product be properly connected to an appropriate earth ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided for this purpose. Connecting a length of heavy gauge (12 AWG min.) copper wire between the generator Ground Terminal and a copper rod driven into the ground should provide a suitable ground connection. However, consult with a local electrician to insure that local codes are being adhered to.
The unit is equipped with a low oil sensor. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine.
If generator shuts off and the oil level is within specifications, check to see if generator is sitting at an angle that forces oil to shift. Place on an even surface to correct this. If engine fails to start, the oil level may not be sufficient to deactivate low oil level switch. Make sure the sump is completely full of oil.

Fill the tank with clean, fresh unleaded automotive gasoline. Regular grade gasoline may be used provided a high octane rating is obtained (at least 85 pump octane). We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.
Do not use a pipe carrying combustible material as the ground source.
Do not overfill the tank. Keep maximum fuel level 1/4 inch below the top of the fuel tank. This will allow expansion in hot weather and prevent overflow.
English Customer Hotline 1-800-445-1805 6
Ground Terminal

A. Control Panel NOTE: Total power drawn from all receptacles must not exceed the nameplate ratings.
E. Ground Terminal
F. Hour Meter
B. 120 V, 20 Ampere Receptacle 20 amps of current may be drawn from the receptacle. However, total power drawn must be kept within nameplate ratings.
G. Engine On/Off Switch
H. 212 CC OHV Engine
I. Recoil Starter
C. 120/240 V, 30 Ampere Twistlock Receptacle Maximum full load current may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. Total current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.
J. Engine Choke Lever
K. Oil Filler Cap
L. Oil Drain Plug
M. 4 Gallon Metal Fuel Tank
D. Circuit Protectors The receptacles are protected by an AC circuit protector. If the generator is overloaded or an external short circuit occurs, the circuit protector will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit protector to trip, reduce the load. NOTE: Continuous tripping of the circuit protector may cause damage to generator or equipment. The circuit protector may be reset by pushing the button of the protector.
N. Fuel Tank Cap
O. Fuel Gauge
P. Fuel Shut-Off


GENERA GENERATOR FEA OR FEATURES - DC USAGE TURES - DC USAGE
Q. DC Usage
This Generator is equipped with a cigarette lighter style 12V DC receptacle. The maximum draw for this DC outlet is 8.3 Amps. The 12V DC receptacle is not intended for use to charge automotive batteries.
The cigarette lighter style receptacle permits the use of any electrical device designed for use in a 12V DC cigarette style outlet similar to ones found in automobiles. The electrical device has a power cord with a metal pin on the bottom and two leaf springs on the sides. Some common automotive type electrical devices are inflators, vacuum cleaners, chargers of various types and more.
To Use: Simply plug the electrical device power cord into the 12V DC outlet and ensure the power cord is securely in place. Use the device as instructed. Remove after use by simply pulling the power cord out of the receptacle.
R. DC Circuit Protector
A DC circuit protector has been provided to protect the circuit from overloads. If an overload occurs, the circuit protector will trip. The circuit protector may be reset by pushing the button of the protector.
8 Customer Hotline 1-800-445-1805 English



9 Customer Hotline 1-800-445-1805
English


Gasoline is very dangerous. Serious injury or death may result from fire caused by gasoline contacting hot surfaces. 1. Do not fill fuel tank with engine running. 2. Do not spill fuel while refilling tank. 3. Do not mix oil with gasoline. 4. Follow all instructions and warnings in the operator manual.
This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.
Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.
When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.
This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.
STARTING THE ENGINE 1. Check oil level and fuel. 2. Disconnect all electrical loads from the unit. 3. Open fuel shut off valve. 4. Adjust choke as necessary. 5. Set the engine switch to the “ON" position. 6. Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke.
Do not apply heavy electrical load during break-in period (the first two to three hours of operations).
SHUTTING THE GENERATOR OFF 1. Remove entire electrical load. 2. Let the engine run for two minutes without load. 3. Move the engine switch to the “OFF” position. 4. Do not leave the generator until it has completely stopped. 5. Close the fuel shut off valve if the engine is to be put in storage or transported. 6. If a cover is used, do not install until unit has cooled. 7. If the generator will not be used again for an extended time period, refer to the SERVICE AND STORAGE section of this manual.

Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.
Customer Hotline 1-800-445-1805 10 English

OIL REPLACEMENT 1. Change oil while engine is warm. 2. Place the generator unit on a level surface. 3. Remove the oil filler cap. 4. Open the oil drain plug and let oil drain completely into a pan placed under the engine. 5. Check gaskets. Replace if required. 6. Reinstall the oil drain plug and refill engine with clean oil. 7. Replace the oil filler cap.
Remove the spark plug and clean the electrodes section with a wire brush or sandpaper. Next, set the gap at .028/.031 inches (0.7-0.8 mm) by adjusting the negative electrode. Replace the spark plug with correct torque: 14 ft-lb (20 N.m)
AIR FILTER CLEANING 1. Unscrew the air filter cover. 2. Remove filter element and wash well in solvent. 3. Pour a small amount of oil onto the filter element and gently squeeze out any excess oil. 4. Replace the filter element and air filter cover. 5. Be sure the filter cover seals properly all around.
Replace with only the same type of spark plug which was removed. An improper spark plug can cause the engine to overheat, emit smoke, or otherwise perform poorly.
Use new good quality oil, SJ or later service category. The oil to be used depends upon the temperature at which the engine is operated:
FUEL VALVE FILTER CLEANING 1. Remove the cup at the bottom of the fuel valve with a small wrench. 2. Remove the fuel valve filter. 3. Clean and wash out the filter and cup and replace.
Below 32° F (0° C) SAE 10W, 10W-30, or 10W-40 32 to 80° F (0 to 25° C) SAE 20W, 10W-30, or 10W-40 80 to 95° F (25 to 35° C) SAE 30W, 10W-30, or 10W-40 Above 95° F (35° C) SAE 40W
FUEL STRAINER CLEANING 1. Remove the plastic fuel strainer, located below the fuel tank cap. 2. Wash the strainer in solvent and replace.
Customer Hotline 1-800-445-1805 11 English




Type 4-stroke, single cylinder, gasoline, OHV Displacement 212 cc, 12.94 cubic inches Maximum HP 7.0 HP @ 3600 rpm Starting System Recoil (electronic ignition) Driving System Direct coupling, tapered crank Oil Capacity 20 oz. Spark Plug NGK BP6ES or equivalent Governor Mechanical (adjustable) Cooling System Forced air cooling Carburetor Type Float Air Cleaner Type Foam element
13 Customer Hotline 1-800-445-1805
English

LIMITED W LIMITED WARRANTY ARRANTY SER SERVICE INFORMA VICE INFORMATION TION
Warranty Coverage: Pramac America, LLC (the Company) warrants to the original retail customer in North America that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship.
PRAMAC AMERICA
PRODUCT SERVICE
Not Covered: · Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer. · If a separate operator's manual and engine warranty from the engine manufacturer is included with this product, only that warranty will apply to the engine. · Damages caused by abuse or accident, and the effects of corrosion, erosion and normal wear and tear. · Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner's manual, or if the product is used as rental equipment. · The Company will not pay for repairs or adjustments to the product, or for any costs or labor, performed without the Company's prior authorization.
1-800-445-1805
or at www.powermate.com
to obtain warranty service
information or to order
replacement parts or
accessories.
Warranty Period: Two (2) years from the date of purchase on products used solely for consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to one (1) year from the date of purchase. For warranty service, the customer must provide dated proof of purchase and must notify the Company within the warranty period.
Even quality built equipment such as the electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the following information:
For warranty service: Call toll free 800-445-1805, or write to Pramac America, LLC, Product Services, 4970 Airport Road, P. O. Box 6001, Kearney, NE 68847.
EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.
4970 Airport Road P. O. Box 6001 Kearney, NE 68847
1-800-445-1805 www.powermate.com
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties, or the exclusion or limitation of incidental and consequential damages, so the above disclaimers and exclusions may not apply to you.
Customer Hotline 1-800-445-1805 14 English
Pramac America, LLC


Type A quatre temps, à un cylindre, à essence, OHV Cylindrée 212 cc CV maximum 7.0 cv à 3600 tr/min Système de démarrage A détente (allumage électronique) Système de propulsion Accouplement direct, bilegrequin effilé Capacité d’huile 0.6 litre Bougie NGK BP6ES ou l’équivalent Régulation Mécanique (ajustable) Système de refroidissement Refroidissement à air forcé Type de carburateur A flotteur Type filtre Elément en mousse