EN
Powermate logo
Official user manual

Powermate PM0103007

44 pages·2.1 MB·Portable Generator·PDF·ENDEFRITNLJA
Powermate PM0103007
Table of Contents 29 sections SAFETY SAFETY INFORMA INFORMA TION TION · SAFETY AND OPERATION RULES · OPERA OPERA TING VOL TING VOL TAGE AGE · INST INST ALLA ALLA TION TION · … ShowHide
Page 2 of the Powermate PM0103007 user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Powermate PM0103007 user manual
Page 3 of the Powermate PM0103007 user manual — SAFETY AND OPERATION RULES
Page 3 · click to enlarge
Page 3

SAFETY SAFETY INFORMA INFORMA TION TION

Powermate PM0103007 — SAFETY SAFETY INFORMA INFORMA TION TION diagram (page 3)
Fig. 1
Powermate PM0103007 — SAFETY SAFETY INFORMA INFORMA TION TION diagram (page 3)
Fig. 2
Powermate PM0103007 — SAFETY SAFETY INFORMA INFORMA TION TION diagram (page 3)
Fig. 3

hazardous situation which, if not avoided, WILL result in death or

hazardous situation which, if not

avoided, may result in minor or

which, if not avoided, could result in death or serious injury.

moderate personal injury, or

serious injury.

property damage.

SAFETY AND OPERATION RULES

11. Store the generator in a well ventilated area with the fuel tank empty. Fuel should not be stored near the generator.
1. Read carefully and understand operator manual prior to operation of this product. Follow all warnings and instructions.

12.Your generator should never be operated under these conditions: a. Uncontrolled change in engine speed. b. Electrical output loss. c. Overheating in connected equipment. d. Sparking. e. Damaged receptacles. f. Engine misfire. g. Excessive vibration. h. Flame or smoke. i. Enclosed compartment. j. Rain, snow or inclement weather. Do not let

2. Know your equipment. Consider the applications, limitations, and the potential hazards specific to your unit.
3. Equipment must be placed on a firm, supporting surface.
4. Load must be kept within rating stated on generator nameplate. Overloading will damage the unit or shorten its life.

the unit get wet when operating.

13.Check the fuel system periodically for leaks or signs of deterioration such as chafed or spongy hose, loose or missing clamps, or damaged tank or cap. All defects should be corrected before operation.

5. Engine must not be run at excessive speeds. Operating an engine at excessive speeds increases the hazard of personal injury. Do not tamper with parts which may increase or decrease the governed speed.

14.The generator should be operated, serviced, and refueled only under the following conditions: a. Start and run the generator outdoors. Do

6. To prevent accidental starting, always remove the spark plug or cable from the spark plug before maintaining the generator or engine.

not run the generator in an enclosed area, even if doors or windows are open; avoid areas where vapors may be trapped, such as pits, garages, cellars, excavations and boat bilges. DANGER - CARBON MONOXIDE HAZARD: The engine exhaust contains carbon monoxide, a poisonous, odorless, invisible gas which, if breathed, may cause death or serious personal injury. If you start to feel sick, dizzy or weak while using the generator, shut it off and get to fresh air right away; you may have carbon monoxide poisoning. b.Good ventilation for cooling. Air flow and

7. Units with broken or missing parts, or without protective housing or covers, should never be operated. Contact your service center for replacement parts.
8. Units should not be operated or stored in wet or damp conditions or on highly conductive locations such as metal decking and steel work.
9. Keep the generator clean and free of oil, mud and other foreign matter.

10.Extension cords, power cords, and all electrical equipment must be in good condition. Never operate electrical equipment with damaged or defective cords.

temperatures are important for air cooled units. Temperatures should not exceed 104º F ambient (40º C). c. Refuel the generator in a well lighted area.

Avoid fuel spills and never refuel while the generator is running. Allow engine to cool for two minutes prior to refueling.

English Customer Hotline 1-800-445-1805 3

Page 4 of the Powermate PM0103007 user manual — SAFETY SAFETY INFORMA INFORMA TION TION
Page 4 · click to enlarge
Page 4
d. Do not refuel near open flames, pilot lights, or SPARK ARRESTER sparking electrical equipment such as power tools, welders, and grinders. e. The muffler and air cleaner must be installed YOUR PRODUCT MAY NOT BE EQUIPPED WITH and in good condition at all times as they A SPARK ARRESTING MUFFLER. If the product will be function as flame arresters if backfiring occurs. used around flammable materials, such as agricultural crops, f. Do not smoke near the generator. forests, brush, grass, or other similar items, then an approved spark arrester should be installed and is legally required in the 15.Ensure that generator is properly grounded. (See State of California. The California statutes requiring a spark “Grounding the generator” section in this arrester are Sections 13005(b), 4442 and 4443. Spark manual.) Arresters are also required on some U.S. Forest Service land and may also be legally required under other statutes and 16.Do not wear loose clothing, jewelry, or anything ordinances. An approved spark arrester is available from our that may be caught in the starter or other rotating product dealers, or may be ordered from Pramac America, parts. LLC, P.O. Box 6001, Kearney, Nebraska 68847. 1-800-445-1805. 17.Unit must reach operating speed before electrical loads are connected. Disconnect loads before turning off engine. DETERMINING TOTAL WATTAGE 18.To prevent surging that may possibly damage equipment, do not allow engine to run out of fuel In order to prevent overloading and possible damage to when electrical loads are applied. your generator it is necessary to know the total wattage of the connected load. To determine which tools and/or appliances 19.When powering solid state equipment, a Power your generator will run follow these steps: Line Conditioner should be used to avoid possible damage to equipment. 1. Determine if you want to run one item or multiple items simultaneously. 20. Do not stick anything through ventilating slots, 2. Check wattage requirements for the items you will be even when the generator is not operating. This can running by referring to the load’s nameplate or by damage the generator or cause personal injury. calculating it (multiply amps x volts = watts). 3. Total the watts for each item. If the nameplate only gives 21.Before transporting the generator in a vehicle, volts and amps, multiply volts x amps = watts. drain all fuel to prevent leakage that may occur. 1 KW = 1,000 watts. 4. Motorized appliances or tools require more than their 22.Use proper lifting techniques when transporting rated wattage for start up. the generator from site to site. Improper lifting techniques may result in personal injury. NOTE: Allow 2 1/2 to 4 times the listed wattage for starting equipment powered by electric motors. 5. The generator’s rated watts should match or exceed the total number of watts required for the equipment you 23.To avoid burns, do not touch engine muffler or want to run. other engine or generator surfaces which became 6. Always connect the heaviest load to the generator first, hot during operation. then add other items one at a time.SPARK ARRESTER English4Customer Hotline 1-800-445-1805Customer Hotline 1-800-445-1805
Powermate PM0103007 — SAFETY SAFETY INFORMA INFORMA TION TION diagram (page 4)
Fig. 4
Page 5 of the Powermate PM0103007 user manual — INST INST ALLA ALLA TION TION
Page 5 · click to enlarge
Page 5

OPERA OPERA TING VOL TING VOL TAGE AGE

To avoid backfeeding into utility systems, isolation of the residence electrical system is required.

Powermate PM0103007 — OPERA OPERA TING VOL TING VOL TAGE AGE diagram (page 5)
Fig. 5

Before temporary connection of the generator to the residence electrical system, turn off the main service/disconnect.

CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.

If your generator is to be used as a stand-by power source in case of utility power failure, it should be installed by a registered electrician and in compliance with all applicable local electrical codes.

Proper use requires that a double throw transfer switch be installed by a licensed qualified electrician so that the building's electrical circuits may be safely switched between utility power and the generator's output, thereby preventing backfeed into the power utility's electrical system.

A power line conditioner should be used when running one or more of the following solid state items:

Powermate PM0103007 — OPERA OPERA TING VOL TING VOL TAGE AGE diagram (page 5)
Fig. 6

Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment

To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system. California law requires isolation of the residence electrical system before connecting a generator to residence electrical systems. Temporary connection not recommended due to backfeeding.

Other solid state equipment may require a power line conditioner. For more information, contact our Customer Service Department at 1-800-445-1805.

INST INST ALLA ALLA TION TION

Always follow local codes and regulations that apply to the installation of any item that concerns this product.

1. NFPA 70 - National Electrical Code. 2. NFPA 37 - Standard for Installation and Use of Stationary Combustible Engines. 3. Agricultural Wiring handbook of Farm Standby Electric Power.

To avoid possible personal injury or equipment damage, a registered electrician or an authorized service representative should perform installation and all service. Under no circumstances should an unqualified person attempt to wire into a utility circuit.

5 English Customer Hotline 1-800-445-1805

Page 6 of the Powermate PM0103007 user manual — FUEL
Page 6 · click to enlarge
Page 6

BEFORE OPERA BEFORE OPERA TION TION

LUBRICATION

DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil. Your generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.

GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION

Some jobsites and local codes may require GFCI protection for personnel before operation of your generator. If your generator is not already equipped with a GFCI receptacle, GFCI In-line cord sets may be purchased from your local electrical supply store or home builder appliance store.

Fill the engine with oil according to the operator manual. For units with a dipstick, fill oil to the proper level. Units without a dipstick should be filled to the top of the opening of the oil fill.

These cord sets are available in various plug and amperage configurations. (Make sure your generator is properly Grounded.)

Powermate PM0103007 — GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION diagram (page 6)
Fig. 7

GROUNDING THE GENERATOR

The National Electric Code requires that this product be properly connected to an appropriate earth ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided for this purpose. Connecting a length of heavy gauge (12 AWG min.) copper wire between the generator Ground Terminal and a copper rod driven into the ground should provide a suitable ground connection. However, consult with a local electrician to insure that local codes are being adhered to.

LOW OIL SENSOR

The unit is equipped with a low oil sensor. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine.

GROUND TERMINAL LOCATION:

If generator shuts off and the oil level is within specifications, check to see if generator is sitting at an angle that forces oil to shift. Place on an even surface to correct this. If engine fails to start, the oil level may not be sufficient to deactivate low oil level switch. Make sure the sump is completely full of oil.

Powermate PM0103007 — GROUND TERMINAL LOCATION: diagram (page 6)
Fig. 8

FUEL

Fill the tank with clean, fresh unleaded automotive gasoline. Regular grade gasoline may be used provided a high octane rating is obtained (at least 85 pump octane). We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

Do not use a pipe carrying combustible material as the ground source.

Do not overfill the tank. Keep maximum fuel level 1/4 inch below the top of the fuel tank. This will allow expansion in hot weather and prevent overflow.

English Customer Hotline 1-800-445-1805 6

Ground Terminal

Page 7 of the Powermate PM0103007 user manual — GENERA GENERA TOR FEA OR FEA TURES TURES
Page 7 · click to enlarge
Page 7

GENERA GENERA TOR FEA OR FEA TURES TURES

A. Control Panel NOTE: Total power drawn from all receptacles must not exceed the nameplate ratings.

E. Ground Terminal

F. Hour Meter

B. 120 V, 20 Ampere Receptacle 20 amps of current may be drawn from the receptacle. However, total power drawn must be kept within nameplate ratings.

G. Engine On/Off Switch

H. 212 CC OHV Engine

I. Recoil Starter

C. 120/240 V, 30 Ampere Twistlock Receptacle Maximum full load current may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. Total current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.

J. Engine Choke Lever

K. Oil Filler Cap

L. Oil Drain Plug

M. 4 Gallon Metal Fuel Tank

D. Circuit Protectors The receptacles are protected by an AC circuit protector. If the generator is overloaded or an external short circuit occurs, the circuit protector will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit protector to trip, reduce the load. NOTE: Continuous tripping of the circuit protector may cause damage to generator or equipment. The circuit protector may be reset by pushing the button of the protector.

N. Fuel Tank Cap

O. Fuel Gauge

P. Fuel Shut-Off

O N M G R F J C P A E I H K D Q L B English7Customer Hotline 1-800-445-1805
Powermate PM0103007 — GENERA GENERA TOR FEA OR FEA TURES TURES diagram (page 7)
Fig. 9
Page 8 of the Powermate PM0103007 user manual — GENERA GENERA TOR FEA OR FEA TURES TURES
Page 8 · click to enlarge
Page 8

GENERA GENERATOR FEA OR FEATURES - DC USAGE TURES - DC USAGE

Q. DC Usage

This Generator is equipped with a cigarette lighter style 12V DC receptacle. The maximum draw for this DC outlet is 8.3 Amps. The 12V DC receptacle is not intended for use to charge automotive batteries.

The cigarette lighter style receptacle permits the use of any electrical device designed for use in a 12V DC cigarette style outlet similar to ones found in automobiles. The electrical device has a power cord with a metal pin on the bottom and two leaf springs on the sides. Some common automotive type electrical devices are inflators, vacuum cleaners, chargers of various types and more.

To Use: Simply plug the electrical device power cord into the 12V DC outlet and ensure the power cord is securely in place. Use the device as instructed. Remove after use by simply pulling the power cord out of the receptacle.

R. DC Circuit Protector

A DC circuit protector has been provided to protect the circuit from overloads. If an overload occurs, the circuit protector will trip. The circuit protector may be reset by pushing the button of the protector.

8 Customer Hotline 1-800-445-1805 English

Page 9 of the Powermate PM0103007 user manual — GENERA GENERA TOR FEA OR FEA TURES TURES
Page 9 · click to enlarge
Page 9
PORTABILITY KIT INSTALLATION PORTABILITY KIT PART NUMBER: 0068403 TOOLS REQUIRED: 10mm and 13mm sockets and ratchets, block(s) of wood (minimum of 6” tall). WHEEL INSTALLATION 1. Block up the alternator end of generator to install wheel kit. 2. Slide the wheel (item 12) onto the axle (item 13). 3. Slide axle through the wheel bracket on the carrier, with the offset side of the wheel hub against the wheel bracket. 4. Secure the wheel to the axle with the size 16 washer (item 14) and cotter pin (item 11). 5. Repeat above instructions for the remaining wheel. FOOT INSTALLATION 1. Blocking up the engine side of the generator, assemble the foot bracket (items 6, 8, and 9) to the carrier (align with holes in tubing) using two M6 x 40 bolts (item 7). Thread M6 nuts (item 10) to the bolts to secure the assembly. 2. Repeat above instructions for the remaining foot. HANDLE INSTALLATION 1. Slide M8 x 40 bolt (item 4) through handle (items 1 and 2) and handle bracket as shown in diagram and secure with M8 nut (item 5). Tighten until handle is securely clamped to the carrier. 2. Repeat above instructions for the remaining handle. LOCKING HANDLE 1. Attach the lanyards (item 15) to the release pins (item 3) and carrier as shown in the illustration. 2. To lock the handle in the extended position, align the holes in the handle brackets with the holes in the carrier brackets and insert the release pins. 1 15 32
Powermate PM0103007 — GENERA GENERA TOR FEA OR FEA TURES TURES diagram (page 9)
Fig. 10
Powermate PM0103007 — GENERA GENERA TOR FEA OR FEA TURES TURES diagram (page 9)
Fig. 11

9 Customer Hotline 1-800-445-1805

English

Page 10 of the Powermate PM0103007 user manual — PRE-START PREPARATION
Page 10 · click to enlarge
Page 10

ST ST ARTING THE UNIT ARTING THE UNIT

Powermate PM0103007 — ST ST ARTING THE UNIT ARTING THE UNIT diagram (page 10)
Fig. 12
  • Provide adequate ventilation for toxic exhaust gases and cooling air flow.
  • Do not start or run the generator in an enclosed area, even if door or windows are open.
  • Engines give off carbon monoxide, an odorless, colorless, poison gas.
  • Breathing carbon monoxide can cause nausea, fainting or death.

Gasoline is very dangerous. Serious injury or death may result from fire caused by gasoline contacting hot surfaces. 1. Do not fill fuel tank with engine running. 2. Do not spill fuel while refilling tank. 3. Do not mix oil with gasoline. 4. Follow all instructions and warnings in the operator manual.

APPLYING LOAD

This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.

PRE-START PREPARATION

Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.

When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.

This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.

STARTING THE ENGINE 1. Check oil level and fuel. 2. Disconnect all electrical loads from the unit. 3. Open fuel shut off valve. 4. Adjust choke as necessary. 5. Set the engine switch to the “ON" position. 6. Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke.

Do not apply heavy electrical load during break-in period (the first two to three hours of operations).

SHUTTING THE GENERATOR OFF 1. Remove entire electrical load. 2. Let the engine run for two minutes without load. 3. Move the engine switch to the “OFF” position. 4. Do not leave the generator until it has completely stopped. 5. Close the fuel shut off valve if the engine is to be put in storage or transported. 6. If a cover is used, do not install until unit has cooled. 7. If the generator will not be used again for an extended time period, refer to the SERVICE AND STORAGE section of this manual.

Powermate PM0103007 — PRE-START PREPARATION diagram (page 10)
Fig. 13

Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.

Customer Hotline 1-800-445-1805 10 English

Page 11 of the Powermate PM0103007 user manual — OIL TYPE
Page 11 · click to enlarge
Page 11
PERIODIC MAINTENANCE ITEMNOTESDaily (Before operation)Initial 20 hoursEvery 50 hoursEvery 100 hours Spark PlugCheck condition. Adjust gap and clean. Replace if necessary.9 Engine OilCheck oil level.9 Replace.99 Air FilterClean, replace if necessary.9 Fuel FilterClean fuel filter and fuel tank strainer. Replace if necessary.9 Fuel LineCheck fuel hose for cracks or other damage. Replace if necessary.9 Exhaust SystemCheck for leakage. Retighten or replace gasket if necessary.9 Check muffler screen. Clean/replace if necessary.9 CarburetorCheck choke operation.9 Starting SystemCheck recoil starter operation.9 Fittings/ FastenersCheck. Replace if necessary.9

MAINTENANCE MAINTENANCE

OIL REPLACEMENT 1. Change oil while engine is warm. 2. Place the generator unit on a level surface. 3. Remove the oil filler cap. 4. Open the oil drain plug and let oil drain completely into a pan placed under the engine. 5. Check gaskets. Replace if required. 6. Reinstall the oil drain plug and refill engine with clean oil. 7. Replace the oil filler cap.

SPARK PLUG

Remove the spark plug and clean the electrodes section with a wire brush or sandpaper. Next, set the gap at .028/.031 inches (0.7-0.8 mm) by adjusting the negative electrode. Replace the spark plug with correct torque: 14 ft-lb (20 N.m)

AIR FILTER CLEANING 1. Unscrew the air filter cover. 2. Remove filter element and wash well in solvent. 3. Pour a small amount of oil onto the filter element and gently squeeze out any excess oil. 4. Replace the filter element and air filter cover. 5. Be sure the filter cover seals properly all around.

Replace with only the same type of spark plug which was removed. An improper spark plug can cause the engine to overheat, emit smoke, or otherwise perform poorly.

OIL TYPE

Use new good quality oil, SJ or later service category. The oil to be used depends upon the temperature at which the engine is operated:

FUEL VALVE FILTER CLEANING 1. Remove the cup at the bottom of the fuel valve with a small wrench. 2. Remove the fuel valve filter. 3. Clean and wash out the filter and cup and replace.

Below 32° F (0° C) SAE 10W, 10W-30, or 10W-40 32 to 80° F (0 to 25° C) SAE 20W, 10W-30, or 10W-40 80 to 95° F (25 to 35° C) SAE 30W, 10W-30, or 10W-40 Above 95° F (35° C) SAE 40W

FUEL STRAINER CLEANING 1. Remove the plastic fuel strainer, located below the fuel tank cap. 2. Wash the strainer in solvent and replace.

Customer Hotline 1-800-445-1805 11 English

Page 12 of the Powermate PM0103007 user manual — MAINTENANCE MAINTENANCE
Page 12 · click to enlarge
Page 12
GENERATOR: Brushes QUICK STARTING TIPS FOR UNITS THAT HAVE The brushes in the generator should be inspected once BEEN SITTING FOR AWHILE: every year for chips and cracks. Brushes should be replaced If your unit has been sitting around for a long time period when they are worn to 1/4 inch (7mm). and is hard to start, try doing some of these easy steps before NOTE: Replace brushes in sets only, never separately. calling the Customer Hotline. Replace only with brushes specified in parts list. Other brushes may appear to be identical but may have 1. Check the oil level. completely different mechanical and electrical characteristics. 2. Replace the old fuel. INSPECTING THE BRUSHES: 3. Change the spark plug. 1. Remove 2 screws (V) and end cover (W). 2. Remove screw (X) holding the brush module (Y). 4. Check the fuel lines. Make sure the fuel valve is open. 3. Disconnect the blue (+) and yellow (-) brush wires from the tabs. 5. Check all generator parts for integrity. 4. Replace if worn to 1/4 inch (7mm). 5. Do not over tighten screw. 6. Clean the Carburetor. SERVICE AND STORAGE INFREQUENT SERVICE If the unit is used infrequently, difficult starting may result. To eliminate hard starting, follow these instructions: 1. Run the generator at least 30 minutes every month. 2. Run the generator, then close the fuel shut-off valve and allow the unit to run until the engine stops. 3. Move the engine switch to the “OFF” position. LONG TERM STORAGE When the generator set is not being operated or is being stored more than one month, follow these instructions: 1. Replenish engine oil to upper level. HEAT SHIELD: 2. Run the generator, then close the fuel shut-off valve and Inspect to ensure that all heat shields and heat deflectors allow the unit to run until the engine stops. are intact and in place. Do not remove any parts or modify 3. Move the engine switch to the “OFF” position. parts. Removing or modifying parts could cause serious 4. After the unit has cooled, drain gasoline from fuel tank, damage to the unit. fuel line and carburetor. 5. Pour about one teaspoon of engine oil through the spark ENGINE: Carburetor Icing plug hole, pull the recoil starter several times and replace During the winter months, rare atmospheric conditions the plug. Then pull the starter until you feel the piston is may develop which will cause an icing condition in the on its compression stroke and leave it in that position. carburetor. If this develops, the engine may run rough, loose This closes both the intake and exhaust valves to prevent power, and may stall. Call Product Service for more the inside of the cylinder from rusting. information. 6. Cover the unit and store in a clean, dry place that is well ventilated away from open flame or sparks. NOTE: We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container. English12Customer Hotline 1-800-445-1805
Powermate PM0103007 — MAINTENANCE MAINTENANCE diagram (page 12)
Fig. 14
Page 13 of the Powermate PM0103007 user manual — ENGINE SPECIFICA ENGINE SPECIFICA TIONS TIONS
Page 13 · click to enlarge
Page 13

ENGINE TROUBLESHOOTING ENGINE TROUBLESHOOTING

Powermate PM0103007 — ENGINE TROUBLESHOOTING ENGINE TROUBLESHOOTING diagram (page 13)
Fig. 15

ENGINE SPECIFICA ENGINE SPECIFICA TIONS TIONS

Type 4-stroke, single cylinder, gasoline, OHV Displacement 212 cc, 12.94 cubic inches Maximum HP 7.0 HP @ 3600 rpm Starting System Recoil (electronic ignition) Driving System Direct coupling, tapered crank Oil Capacity 20 oz. Spark Plug NGK BP6ES or equivalent Governor Mechanical (adjustable) Cooling System Forced air cooling Carburetor Type Float Air Cleaner Type Foam element

13 Customer Hotline 1-800-445-1805

English

Page 14 of the Powermate PM0103007 user manual — HOW TO ORDER REPLACEMENT PARTS
Page 14 · click to enlarge
Page 14

LIMITED W LIMITED WARRANTY ARRANTY SER SERVICE INFORMA VICE INFORMATION TION

Warranty Coverage: Pramac America, LLC (the Company) warrants to the original retail customer in North America that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship.

CONTACT THE

PRAMAC AMERICA

PRODUCT SERVICE

Not Covered: · Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer. · If a separate operator's manual and engine warranty from the engine manufacturer is included with this product, only that warranty will apply to the engine. · Damages caused by abuse or accident, and the effects of corrosion, erosion and normal wear and tear. · Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner's manual, or if the product is used as rental equipment. · The Company will not pay for repairs or adjustments to the product, or for any costs or labor, performed without the Company's prior authorization.

DEPARTMENT AT

1-800-445-1805

or at www.powermate.com

to obtain warranty service

information or to order

replacement parts or

accessories.

HOW TO ORDER REPLACEMENT PARTS

Warranty Period: Two (2) years from the date of purchase on products used solely for consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to one (1) year from the date of purchase. For warranty service, the customer must provide dated proof of purchase and must notify the Company within the warranty period.

Even quality built equipment such as the electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the following information:

1. Model No. and Serial No. and all specifications shown on the Model No./Serial No. plate. 2. Part number or numbers as shown in the Parts List section. 3. A brief description of the trouble with the generator.

For warranty service: Call toll free 800-445-1805, or write to Pramac America, LLC, Product Services, 4970 Airport Road, P. O. Box 6001, Kearney, NE 68847.

EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.

4970 Airport Road P. O. Box 6001 Kearney, NE 68847

1-800-445-1805 www.powermate.com

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties, or the exclusion or limitation of incidental and consequential damages, so the above disclaimers and exclusions may not apply to you.

Customer Hotline 1-800-445-1805 14 English

Pramac America, LLC

Page 25 of the Powermate PM0103007 user manual — CARACTERISTIQUES DU MOTEUR CARACTERISTIQUES DU MOTEUR
Page 25 · click to enlarge
Page 25

DEP DEP ANNAGE DU MOTEUR ANNAGE DU MOTEUR

Powermate PM0103007 — DEP DEP ANNAGE DU MOTEUR ANNAGE DU MOTEUR diagram (page 25)
Fig. 16

CARACTERISTIQUES DU MOTEUR CARACTERISTIQUES DU MOTEUR

Type A quatre temps, à un cylindre, à essence, OHV Cylindrée 212 cc CV maximum 7.0 cv à 3600 tr/min Système de démarrage A détente (allumage électronique) Système de propulsion Accouplement direct, bilegrequin effilé Capacité d’huile 0.6 litre Bougie NGK BP6ES ou l’équivalent Régulation Mécanique (ajustable) Système de refroidissement Refroidissement à air forcé Type de carburateur A flotteur Type filtre Elément en mousse

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Powermate PM0103007

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Powermate PM0103007

Be the first to ask — other owners or our team will answer.

Original document

Powermate PM0103007 manual PDF

44 pages·2.1 MB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…