EN
Powermate logo
Official user manual

Powermate PM0103000

40 pages·983 KB·Portable Generator·PDF·ENDEFRITNLJA
Powermate PM0103000
Table of Contents 57 sections Operator Manual Manuel de l’opérateur Manual del operador · PM0103000 · ELECTRIC GENERATOR - GROUPE ELECTROGENE - GENERADOR ELECTRICO · ALTO · … ShowHide
Operator Manual Manuel de l’opérateur Manual del operadorp.1PM0103000p.1ELECTRIC GENERATOR - GROUPE ELECTROGENE - GENERADOR ELECTRICOp.1ALTOp.1STOPp.1ARRÊTp.1DO NOT RETURN TO STORE!p.1NE PAS RETOURNER AU MAGASIN!p.1NO LO DEVUELVA A LA TIENDA!p.1CALL US FIRST!p.1¡PRIMERO LLÁMENOS!p.1APPELEZ–NOUS D’ABORD!p.1CUSTOMER HOTLINEp.1LÍNEA DIRECTA DE ATENCIÓNp.1ASSISTANCE TELEPHONIQUEp.11-800-445-1805 or 1-308-237-2181 FOR QUESTIONS OR SERVICE INFORMATIONp.1A LA CLIENTELEp.1AL CLIENTE 1-800-445-1805 o 1-308-237-2181 PARA la INFORMACION dep.11-800-445-1805 ou 1-308-237-2181 POUR L'INFORMATION DEp.1PREGUNTAS O SERVICIOp.1QUESTIONS OU SERVICEp.1SAFETY AND OPERATION RULESp.3OPERATING VOLTAGEp.5INSTALLATIONp.5BEFORE OPERATIONp.6LOW OIL SENSORp.6GROUNDING THE GENERATORp.6FUELp.6GROUND TERMINAL LOCATION:p.6LUBRICATIONp.6GENERATOR FEATURESp.7K L Mp.7PORTABILITY KIT INSTALLATIONp.8STARTING THE UNITp.9APPLYING LOADp.9PRE-START PREPARATIONp.9PERIODIC MAINTENANCEp.10Spark Plug Check condition. Adjust gap and clean. Replace if necessary. üp.10Check for leakage. Retighten or replace gasket if necessary. üp.10Check muffler screen. Clean/replace if necessary. üp.10Carburetor Check choke operation. ü Starting System Check recoil starter operation. üp.10Fittings/ Fasteners Check. Replace if necessary. üp.10MAINTENANCEp.10SPARK PLUGp.10OIL TYPEp.10ENGINE TROUBLESHOOTINGp.12ENGINE SPECIFICATIONSp.12LIMITED WARRANTY SERVICE INFORMATIONp.13CONTACT THEp.13POWERMATE CORPORATIONp.13PRODUCT SERVICEp.13DEPARTMENT ATp.131-800-445-1805p.13to obtain warranty servicep.13information or to orderp.13replacement parts orp.13HOW TO ORDER REPLACEMENT PARTSp.13
Page 1 of the Powermate PM0103000 user manual — ALTO
Page 1 · click to enlarge
Page 1

Operator Manual Manuel de l’opérateur Manual del operador

Powermate PM0103000 — Operator Manual Manuel de l’opérateur Manual del operador diagram (page 1)
Fig. 1 · Operator Manual Manuel de l’opérateur Manual del ope…

PM0103000

ELECTRIC GENERATOR - GROUPE ELECTROGENE - GENERADOR ELECTRICO

Powermate PM0103000 — ELECTRIC GENERATOR - GROUPE ELECTROGENE - GENERADOR ELECTRICO diagram (page 1)
Fig. 2

Record the serial numbers as indicated on your Generator’s nameplate:

Serial No

Enregistrer le numéro de série figurant sur la plaque signalétique du groupe électrogène:

Nº de série

Registre de serie como se indica en la placa del nombre de su generador:

No. de serie

ALTO

STOP

ARRÊT

DO NOT RETURN TO STORE!

NE PAS RETOURNER AU MAGASIN!

NO LO DEVUELVA A LA TIENDA!

CALL US FIRST!

¡PRIMERO LLÁMENOS!

APPELEZ–NOUS D’ABORD!

CUSTOMER HOTLINE

LÍNEA DIRECTA DE ATENCIÓN

ASSISTANCE TELEPHONIQUE

1-800-445-1805 or 1-308-237-2181 FOR QUESTIONS OR SERVICE INFORMATION

A LA CLIENTELE

AL CLIENTE 1-800-445-1805 o 1-308-237-2181 PARA la INFORMACION de

1-800-445-1805 ou 1-308-237-2181 POUR L'INFORMATION DE

PREGUNTAS O SERVICIO

QUESTIONS OU SERVICE

11/06 0064755

Page 2 of the Powermate PM0103000 user manual — Operator Manual Manuel de l’opérateur Manual del operador
Page 2 · click to enlarge
Page 2
Page 2 of the Powermate PM0103000 user manual — Operator Manual Manuel de l’opérateur Manual del operador
Page 3 of the Powermate PM0103000 user manual — SAFETY AND OPERATION RULES
Page 3 · click to enlarge
Page 3
Powermate PM0103000 — SAFETY AND OPERATION RULES diagram (page 3)
Fig. 3
Powermate PM0103000 — SAFETY AND OPERATION RULES diagram (page 3)
Fig. 4
Powermate PM0103000 — SAFETY AND OPERATION RULES diagram (page 3)
Fig. 5

hazardous situation which, if not

avoided, may result in minor or

which, if not avoided, could result in death or serious injury.

moderate personal injury, or

serious injury.

property damage.

SAFETY AND OPERATION RULES

11. Store the generator in a well ventilated area with the fuel tank empty. Fuel should not be stored near the generator.
1. Read carefully and understand operator manual prior to operation of this product. Follow all warnings and instructions.

12.Your generator should never be operated under these conditions: a. Uncontrolled change in engine speed. b. Electrical output loss. c. Overheating in connected equipment. d. Sparking. e. Damaged receptacles. f. Engine misfire. g. Excessive vibration. h. Flame or smoke. i. Enclosed compartment. j. Rain or inclement weather. Do not let the unit

2. Know your equipment. Consider the applications, limitations, and the potential hazards specific to your unit.
3. Equipment must be placed on a firm, supporting surface.
4. Load must be kept within rating stated on generator nameplate. Overloading will damage the unit or shorten its life.

get wet when operating.

13.Check the fuel system periodically for leaks or signs of deterioration such as chafed or spongy hose, loose or missing clamps, or damaged tank or cap. All defects should be corrected before operation.

5. Engine must not be run at excessive speeds. Operating an engine at excessive speeds increases the hazard of personal injury. Do not tamper with parts which may increase or decrease the governed speed.

14.The generator should be operated, serviced, and refueled only under the following conditions: a. Start and run the generator outdoors. Do

6. To prevent accidental starting, always remove the spark plug or cable from the spark plug before maintaining the generator or engine.

not run the generator in an enclosed area, even if doors or windows are open; avoid areas where vapors may be trapped, such as pits, garages, cellars, excavations and boat bilges. DANGER - CARBON MONOXIDE HAZARD: The engine exhaust contains carbon monoxide, a poisonous, odorless, invisible gas which, if breathed, may cause death or serious personal injury. If you start to feel sick, dizzy or weak while using the generator, shut it off and get to fresh air right away; you may have carbon monoxide poisoning. b.Good ventilation for cooling. Air flow and

7. Units with broken or missing parts, or without protective housing or covers, should never be operated. Contact your service center for replacement parts.
8. Units should not be operated or stored in wet or damp conditions or on highly conductive locations such as metal decking and steel work.
9. Keep the generator clean and free of oil, mud and other foreign matter.

10.Extension cords, power cords, and all electrical equipment must be in good condition. Never operate electrical equipment with damaged or defective cords.

temperatures are important for air cooled units. Temperatures should not exceed 104º F ambient (40º C). c. Refuel the generator in a well lighted area.

Avoid fuel spills and never refuel while the generator is running. Allow engine to cool for two minutes prior to refueling.

English Customer Hotline 1-800-445-1805 3

Page 4 of the Powermate PM0103000 user manual — SAFETY AND OPERATION RULES
Page 4 · click to enlarge
Page 4
d. Do not refuel near open flames, pilot lights, or SPARK ARRESTER sparking electrical equipment such as power tools, welders, and grinders. e. The muffler and air cleaner must be installed YOUR PRODUCT MAY NOT BE EQUIPPED WITH and in good condition at all times as they A SPARK ARRESTING MUFFLER. If the product will be function as flame arresters if backfiring occurs. used around flammable materials, such as agricultural crops, f. Do not smoke near the generator. forests, brush, grass, or other similar items, then an approved spark arrester should be installed and is legally required in the 15.Ensure that generator is properly grounded. (See State of California. The California statutes requiring a spark “Grounding the generator” section in this arrester are Sections 13005(b), 4442 and 4443. Spark manual.) Arresters are also required on some U.S. Forest Service land and may also be legally required under other statutes and 16.Do not wear loose clothing, jewelry, or anything ordinances. An approved spark arrester is available from our that may be caught in the starter or other rotating product dealers, or may be ordered from Powermate parts. Corporation, P.O. Box 6001, Kearney, Nebraska 68848. 1-800-445-1805. 17.Unit must reach operating speed before electrical loads are connected. Disconnect loads before turning off engine. DETERMINING TOTAL WATTAGE 18.To prevent surging that may possibly damage equipment, do not allow engine to run out of fuel In order to prevent overloading and possible damage to when electrical loads are applied. your generator it is necessary to know the total wattage of the connected load. To determine which tools and/or appliances 19.When powering solid state equipment, a Power your generator will run follow these steps: Line Conditioner should be used to avoid possible damage to equipment. 1. Determine if you want to run one item or multiple items simultaneously. 20. Do not stick anything through ventilating slots, 2. Check wattage requirements for the items you will be even when the generator is not operating. This can running by referring to the load’s nameplate or by damage the generator or cause personal injury. calculating it (multiply amps x volts = watts). 3. Total the watts for each item. If the nameplate only gives 21.Before transporting the generator in a vehicle, volts and amps, multiply volts x amps = watts. drain all fuel to prevent leakage that may occur. 1 KW = 1,000 watts. 4. Motorized appliances or tools require more than their 22.Use proper lifting techniques when transporting rated wattage for start up. the generator from site to site. Improper lifting techniques may result in personal injury. NOTE: Allow 2 1/2 to 4 times the listed wattage for starting equipment powered by electric motors. 5. The generator’s rated watts should match or exceed the total number of watts required for the equipment you 23.To avoid burns, do not touch engine muffler or want to run. other engine or generator surfaces which became 6. Always connect the heaviest load to the generator first, hot during operation. then add other items one at a time.SPARK ARRESTER English4Customer Hotline 1-800-445-1805Customer Hotline 1-800-445-1805
Powermate PM0103000 — SAFETY AND OPERATION RULES diagram (page 4)
Fig. 6
Page 5 of the Powermate PM0103000 user manual — INSTALLATION
Page 5 · click to enlarge
Page 5

OPERATING VOLTAGE

To avoid backfeeding into utility systems, isolation of the residence electrical system is required.

Powermate PM0103000 — OPERATING VOLTAGE diagram (page 5)
Fig. 7

Before temporary connection of the generator to the residence electrical system, turn off the main service/disconnect.

CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.

If your generator is to be used as a stand-by power source in case of utility power failure, it should be installed by a registered electrician and in compliance with all applicable local electrical codes.

Proper use requires that a double throw transfer switch be installed by a licensed qualified electrician so that the building's electrical circuits may be safely switched between utility power and the generator's output, thereby preventing backfeed into the power utility's electrical system.

A power line conditioner should be used when running one or more of the following solid state items:

Powermate PM0103000 — OPERATING VOLTAGE diagram (page 5)
Fig. 8

Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment

To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system. California law requires isolation of the residence electrical system before connecting a generator to residence electrical systems. Temporary connection not recommended due to backfeeding.

Other solid state equipment may require a power line conditioner. For more information, contact our Customer Service Department at 1-800-445-1805.

INSTALLATION

Always follow local codes and regulations that apply to the installation of any item that concerns this product.

1. NFPA 70 - National Electrical Code. 2. NFPA 37 - Standard for Installation and Use of Stationary Combustible Engines. 3. Agricultural Wiring handbook of Farm Standby Electric Power.

To avoid possible personal injury or equipment damage, a registered electrician or an authorized service representative should perform installation and all service. Under no circumstances should an unqualified person attempt to wire into a utility circuit.

5 English Customer Hotline 1-800-445-1805

Page 6 of the Powermate PM0103000 user manual — LUBRICATION
Page 6 · click to enlarge
Page 6

BEFORE OPERATION

LOW OIL SENSOR

The unit is equipped with a low oil sensor. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine.

GROUNDING THE GENERATOR

The National Electric Code requires that this product be properly connected to an appropriate earth ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided for this purpose. Connecting a length of heavy gauge (12 AWG min.) copper wire between the generator Ground Terminal and a copper rod driven into the ground should provide a suitable ground connection. However, consult with a local electrician to insure that local codes are being adhered to.

If generator shuts off and the oil level is within specifications, check to see if generator is sitting at an angle that forces oil to shift. Place on an even surface to correct this. If engine fails to start, the oil level may not be sufficient to deactivate low oil level switch. Make sure the sump is completely full of oil.

FUEL

Fill the tank with clean, fresh unleaded automotive gasoline. Regular grade gasoline may be used provided a high octane rating is obtained (at least 85 pump octane). We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

GROUND TERMINAL LOCATION:

Powermate PM0103000 — GROUND TERMINAL LOCATION: diagram (page 6)
Fig. 9

Do not overfill the tank. Keep maximum fuel level 1/4 inch below the top of the fuel tank. This will allow expansion in hot weather and prevent overflow.

Do not use a pipe carrying combustible material as the ground source.

LUBRICATION

DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil. Your generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.

Fill the engine with oil according to the operator manual. For units with a dipstick, fill oil to the proper level. Units without a dipstick should be filled to the top of the opening of the oil fill.

English Customer Hotline 1-800-445-1805 6

Ground Terminal

Page 7 of the Powermate PM0103000 user manual — K L M
Page 7 · click to enlarge
Page 7

GENERATOR FEATURES

A. Control Panel

E. Oil Warning Light

B. 120 V, 20 Ampere Receptacle 20 amps of current may be drawn from each receptacle. However, total power drawn must be kept within nameplate ratings.

F. 6.0 HP OHV Engine

G. Recoil Starter

H. Engine Choke Lever

C. Circuit Breaker The receptacles are protected by AC circuit breakers. If the generator is overloaded or an external short circuit occurs, a circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.

I. Oil Filler Cap

J. Oil Drain Plug

K. 3 Gallon Metal Fuel Tank

L. Fuel Tank Cap

M. Fuel Gauge

D. Engine On/Off Switch

N. Fuel Shut-Off

Powermate PM0103000 — GENERATOR FEATURES diagram (page 7)
Fig. 10

K L M

B

H

N

G

F

A

D

E

J

7 English Customer Hotline 1-800-445-1805

Page 8 of the Powermate PM0103000 user manual — PORTABILITY KIT INSTALLATION
Page 8 · click to enlarge
Page 8

PORTABILITY KIT INSTALLATION

TOOLS REQUIRED: 10mm, 13mm, and 16mm sockets and ratchets, block(s) of wood (minimum of 6” tall). Refer to the parts list on page 37.

WHEEL INSTALLATION 1. Block up the engine end of generator to install wheel kit. 2. Insert wheel spacer (item 165) into the center of the wheel (item 166). 3. Slide M10 x 75 bolt (item 167) through the wheel (item 166), then through the wheel bracket on the carrier, with the offset side of the wheel hub against the wheel bracket. 4. Thread M10 nut (item 163) onto the bolt and tighten to securely clamp the wheel assembly to the carrier. 5. Repeat above instructions for the remaining wheel.

FOOT INSTALLATION 1. Blocking up the alternator side of the generator, assemble the rubber foot (item 161) to the carrier using a M8 x 20 bolt (item 160). Thread a M8 nut (item 162) to the bolt to secure the assembly. Caution: Do not over tighten so that the foot material collapses. 2. Repeat above instructions for the remaining foot.

HANDLE INSTALLATION 1. Place handle (item 156) on carrier on same end as feet, as shown in the diagram. 2. Slide M8 x 40 screw (item 153) through handle and handle bracket as shown in diagram and secure with M8 nyloc nut (item 155). Tighten until handle is securely clamped to the carrier. 3. Slide the handle grip (item 158) onto the handle. Slide square bolt (item 157) through handle grip as shown in diagram and secure with M6 nut (item 159). 4. Insert cap (item 154) into end of handle.

LOCKING HANDLE 1. Attach the lanyard (item 151) to the release pin (item 152) and carrier as shown in the illustration. 2. To lock the handle in the extended position, align the holes in the handle bracket with the holes in the carrier bracket and insert the release pin (item 152).

Powermate PM0103000 — PORTABILITY KIT INSTALLATION diagram (page 8)
Fig. 11
Powermate PM0103000 — PORTABILITY KIT INSTALLATION diagram (page 8)
Fig. 12

8 Customer Hotline 1-800-445-1805 English

152 151

Page 9 of the Powermate PM0103000 user manual — PRE-START PREPARATION
Page 9 · click to enlarge
Page 9

STARTING THE UNIT

Powermate PM0103000 — STARTING THE UNIT diagram (page 9)
Fig. 13
  • Provide adequate ventilation for toxic exhaust gases and cooling air flow.
  • Do not start or run the generator in an enclosed area, even if door or windows are open.
  • Engines give off carbon monoxide, an odorless, colorless, poison gas.
  • Breathing carbon monoxide can cause nausea, fainting or death.

Gasoline is very dangerous. Serious injury or death may result from fire caused by gasoline contacting hot surfaces. 1. Do not fill fuel tank with engine running. 2. Do not spill fuel while refilling tank. 3. Do not mix oil with gasoline. 4. Follow all instructions and warnings in the operator manual.

APPLYING LOAD

This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.

PRE-START PREPARATION

Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.

When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.

This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.

STARTING THE ENGINE 1. Check oil level and fuel. 2. Disconnect all electrical loads from the unit. 3. Open fuel shut off valve. 4. Adjust choke as necessary. 5. Set the engine switch to the “ON" position. 6. Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke. On electric start models, turn the key switch to “START”. Release key switch after the engine starts.

Do not apply heavy electrical load during break-in period (the first two to three hours of operations).

Powermate PM0103000 — PRE-START PREPARATION diagram (page 9)
Fig. 14

SHUTTING THE GENERATOR OFF 1. Remove entire electrical load. 2. Let the engine run for two minutes without load. 3. Move the engine switch to the “OFF” position. (Turn the key switch to “OFF” on the electric start models). 4. Do not leave the generator until it has completely stopped. 5. Close the fuel shut off valve if the engine is to be put in storage or transported. 6. If a cover is used, do not install until unit has cooled.

Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.

Customer Hotline 1-800-445-1805 9 English

Page 10 of the Powermate PM0103000 user manual — OIL TYPE
Page 10 · click to enlarge
Page 10

PERIODIC MAINTENANCE

ITEM NOTES Daily (Before operation)

Initial 20 hours Every 50 hours Every 100 hours

Spark Plug Check condition. Adjust gap and clean. Replace if necessary. ü

Engine Oil Check oil level. ü Replace. ü ü Air Filter Clean, replace if necessary. ü

Fuel Filter Clean fuel filter and fuel tank strainer. Replace if necessary. ü

Fuel Line Check fuel hose for cracks or other damage. Replace if necessary. ü

Check for leakage. Retighten or replace gasket if necessary. ü

Check muffler screen. Clean/replace if necessary. ü

Carburetor Check choke operation. ü Starting System Check recoil starter operation. ü

Fittings/ Fasteners Check. Replace if necessary. ü

MAINTENANCE

OIL REPLACEMENT 1. Change oil while engine is warm. 2. Place the generator unit on a level surface. 3. Remove the oil filler cap. 4. Open the oil drain plug and let oil drain completely into a pan placed under the engine. 5. Check gaskets. Replace if required. 6. Reinstall the oil drain plug and refill engine with clean oil. 7. Replace the oil filler cap.

SPARK PLUG

Remove the spark plug and clean the electrodes section with a wire brush or sandpaper. Next, set the gap at .028/.031 inches (0.7-0.8 mm) by adjusting the negative electrode. Replace the spark plug with correct torque: 14 ft-lb (20 N.m)

AIR FILTER CLEANING 1. Unscrew the air filter cover. 2. Remove filter element and wash well in solvent. 3. Pour a small amount of oil onto the filter element and gently squeeze out any excess oil. 4. Replace the filter element and air filter cover. 5. Be sure the filter cover seals properly all around.

Replace with only the same type of spark plug which was removed. An improper spark plug can cause the engine to overheat, emit smoke, or otherwise perform poorly.

OIL TYPE

Use new good quality oil, SE, SF, or SD grade. The oil to be used depends upon the temperature at which the engine is operated:

FUEL VALVE FILTER CLEANING 1. Remove the cup at the bottom of the fuel valve with a small wrench. 2. Remove the fuel valve filter. 3. Clean and wash out the filter and cup and replace.

Below 32° F (0° C) SAE 10W, 10W-30, or 10W-40 32 to 80° F (0 to 25° C) SAE 20W, 10W-30, or 10W-40 80 to 95° F (25 to 35° C) SAE 30W, 10W-30, or 10W-40 Above 95° F (35° C) SAE 40W

FUEL STRAINER CLEANING 1. Remove the plastic fuel strainer, located below the fuel tank cap. 2. Wash the strainer in solvent and replace.

Customer Hotline 1-800-445-1805 10 English

Exhaust System

Page 11 of the Powermate PM0103000 user manual — PERIODIC MAINTENANCE
Page 11 · click to enlarge
Page 11
EXCITING THE GENERATOR: SERVICE AND STORAGE If there is a loss of residual magnetism (voltage will not build up), it may be necessary to re-excite the unit. INFREQUENT SERVICE If the unit is used infrequently, difficult starting may NOTE: Your generator is a brushless unit. Please contact result. to eliminate hard starting, run the generator at least 30 your local service center or the Powermate Corporation minutes every month. Also, if the unit will not be used for Product Service Department for assistance with exciting some time, it is a good idea to drain the fuel from the your generator. carburetor and gas tank. HEAT SHIELD: LONG TERM STORAGE Inspect to ensure that all heat shields and heat deflectors When the generator set is not being operated or is being are intact and in place. Do not remove any parts or modify stored more than one month, follow these instructions: parts. Removing or modifying parts could cause serious damage to the unit. 1. Replenish engine oil to upper level. ENGINE: Carburetor Icing 2. Drain gasoline from fuel tank, fuel line and carburetor. During the winter months, rare atmospheric conditions may develop which will cause an icing condition in the 3. Pour about one teaspoon of engine oil through the spark carburetor. If this develops, the engine may run rough, loose plug hole, pull the recoil starter several times and replace power, and may stall. Call Product Service for more the plug. Then pull the starter until you feel the piston is information. on its compression stroke and leave it in that position. This closes both the intake and exhaust valves to prevent QUICK STARTING TIPS FOR UNITS THAT HAVE the inside of the cylinder from rusting. BEEN SITTING FOR AWHILE: If your unit has been sitting around for a long time period 4. Cover the unit and store in a clean, dry place that is well and is hard to start, try doing some of these easy steps before ventilated away from open flame or sparks. calling the Customer Hotline. NOTE: We recommend always using a fuel stabilizer. A 1. Check the oil level. fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added 2. Replace the old fuel. to the gasoline in the fuel tank, or into the gasoline in a storage container. 3. Change the spark plug. 4. Check the fuel lines. Make sure the fuel valve is open. 5. Check all generator parts for integrity. 6. Clean the Carburetor.SERVICE AND STORAGE English11Customer Hotline 1-800-445-1805
Page 12 of the Powermate PM0103000 user manual — ENGINE TROUBLESHOOTING
Page 12 · click to enlarge
Page 12

ENGINE TROUBLESHOOTING

ENGINE SPECIFICATIONS

Type 4-stroke, single cylinder, gasoline, OHV Displacement 193 cc, 11.78 cubic inches Maximum HP 6.0 HP @ 3600 rpm Starting System Recoil (electronic ignition) Driving System Direct coupling, tapered crank Oil Capacity 20 oz. Spark Plug Champion RN14YC or equivalent Governor Mechanical (adjustable) Cooling System Forced air cooling Bore x Stroke 66.0 X 50.0 mm (2.60 x 1.97 in.) Carburetor Type Float Air Cleaner Type Foam element

12 www.colemanpowermate.com

English

Page 13 of the Powermate PM0103000 user manual — HOW TO ORDER REPLACEMENT PARTS
Page 13 · click to enlarge
Page 13

LIMITED WARRANTY SERVICE INFORMATION

Warranty Coverage: Powermate Corporation (the Company) warrants to the original retail customer in North America that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship.

CONTACT THE

POWERMATE CORPORATION

PRODUCT SERVICE

Not Covered: · Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer. · If a separate operator's manual and engine warranty from the engine manufacturer is included with this product, only that warranty will apply to the engine. · Damages caused by abuse or accident, and the effects of corrosion, erosion and normal wear and tear. · Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner's manual, or if the product is used as rental equipment. · The Company will not pay for repairs or adjustments to the product, or for any costs or labor, performed without the Company's prior authorization.

DEPARTMENT AT

1-800-445-1805

to obtain warranty service

information or to order

replacement parts or

accessories.

HOW TO ORDER REPLACEMENT PARTS

Even quality built equipment such as the electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the following information:

Warranty Period: One (1) year from the date of purchase on products used solely for consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to ninety (90) days from the date of purchase. For warranty service, the customer must provide dated proof of purchase and must notify the Company within the warranty period.

1. Model No. and Serial No. and all specifications shown on the Model No./Serial No. plate. 2. Part number or numbers as shown in the Parts List section. 3. A brief description of the trouble with the generator.

For warranty service: Call toll free 800-445-1805, or write to Powermate Corporation, Product Services, 4970 Airport Road, P. O. Box 6001, Kearney, NE 68848.

EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.

4970 Airport Road P. O. Box 6001 Kearney, NE 68848

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties, or the exclusion or limitation of incidental and consequential dam- ages, so the above disclaimers and exclusions may not apply to you.

Customer Hotline 1-800-445-1805 13 English

Powermate Corporation · 1-800-445-1805

Page 23 of the Powermate PM0103000 user manual — CARACTERISTIQUES DU MOTEUR
Page 23 · click to enlarge
Page 23

DEPANNAGE DU MOTEUR

Powermate PM0103000 — DEPANNAGE DU MOTEUR diagram (page 23)
Fig. 15

CARACTERISTIQUES DU MOTEUR

Type A quatre temps, à un cylindre, à essence, OHV Cylindrée 193 cc CV maximum 6.0 cv à 3600 tr/min Système de démarrage A détente (allumage électronique) Système de propulsion Accouplement direct, bilegrequin effilé Capacité d’huile 20 oz Bougie Champion RN14YC ou l’équivalent Régulation Mécanique (ajustable) Système de refroidissement Refroidissement à air forcé Alésage x course 66,0 x 50,0 mm Type de carburateur A flotteur Type filtre Elément en mousse

Français Assistance Téléphonique 1-800-445-1805

Ask about the Powermate PM0103000

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Powermate PM0103000

Be the first to ask — other owners or our team will answer.

Original document

Powermate PM0103000 manual PDF

40 pages·983 KB·Portable Generator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…