Record the serial numbers as indicated on your Generator’s nameplate:
Serial No
Enregistrer le numéro de série figurant sur la plaque signalétique du groupe électrogène:
Nº de série
Registre de serie como se indica en la placa del nombre de su generador:
No. de serie
STOP
ARRÊT
DO NOT RETURN TO STORE!
NE PAS RETOURNER AU MAGASIN!
NO LO DEVUELVA A LA TIENDA!
CALL US FIRST!
¡PRIMERO LLÁMENOS!
APPELEZ–NOUS D’ABORD!
CUSTOMER HOTLINE
LÍNEA DIRECTA DE ATENCIÓN
ASSISTANCE TELEPHONIQUE
1-800-445-1805 or 1-308-237-2181 FOR QUESTIONS OR SERVICE INFORMATION
A LA CLIENTELE
AL CLIENTE 1-800-445-1805 o 1-308-237-2181 PARA la INFORMACION de
1-800-445-1805 ou 1-308-237-2181 POUR L'INFORMATION DE
PREGUNTAS O SERVICIO
QUESTIONS OU SERVICE
11/06 0064755






hazardous situation which, if not
avoided, may result in minor or
which, if not avoided, could result in death or serious injury.
moderate personal injury, or
serious injury.
property damage.
12.Your generator should never be operated under these conditions: a. Uncontrolled change in engine speed. b. Electrical output loss. c. Overheating in connected equipment. d. Sparking. e. Damaged receptacles. f. Engine misfire. g. Excessive vibration. h. Flame or smoke. i. Enclosed compartment. j. Rain or inclement weather. Do not let the unit
get wet when operating.
13.Check the fuel system periodically for leaks or signs of deterioration such as chafed or spongy hose, loose or missing clamps, or damaged tank or cap. All defects should be corrected before operation.
14.The generator should be operated, serviced, and refueled only under the following conditions: a. Start and run the generator outdoors. Do
not run the generator in an enclosed area, even if doors or windows are open; avoid areas where vapors may be trapped, such as pits, garages, cellars, excavations and boat bilges. DANGER - CARBON MONOXIDE HAZARD: The engine exhaust contains carbon monoxide, a poisonous, odorless, invisible gas which, if breathed, may cause death or serious personal injury. If you start to feel sick, dizzy or weak while using the generator, shut it off and get to fresh air right away; you may have carbon monoxide poisoning. b.Good ventilation for cooling. Air flow and
10.Extension cords, power cords, and all electrical equipment must be in good condition. Never operate electrical equipment with damaged or defective cords.
temperatures are important for air cooled units. Temperatures should not exceed 104º F ambient (40º C). c. Refuel the generator in a well lighted area.
Avoid fuel spills and never refuel while the generator is running. Allow engine to cool for two minutes prior to refueling.
English Customer Hotline 1-800-445-1805 3



To avoid backfeeding into utility systems, isolation of the residence electrical system is required.

Before temporary connection of the generator to the residence electrical system, turn off the main service/disconnect.
CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner is recommended for some solid state applications.
If your generator is to be used as a stand-by power source in case of utility power failure, it should be installed by a registered electrician and in compliance with all applicable local electrical codes.
Proper use requires that a double throw transfer switch be installed by a licensed qualified electrician so that the building's electrical circuits may be safely switched between utility power and the generator's output, thereby preventing backfeed into the power utility's electrical system.
A power line conditioner should be used when running one or more of the following solid state items:

Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment
To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system. California law requires isolation of the residence electrical system before connecting a generator to residence electrical systems. Temporary connection not recommended due to backfeeding.
Other solid state equipment may require a power line conditioner. For more information, contact our Customer Service Department at 1-800-445-1805.
Always follow local codes and regulations that apply to the installation of any item that concerns this product.
To avoid possible personal injury or equipment damage, a registered electrician or an authorized service representative should perform installation and all service. Under no circumstances should an unqualified person attempt to wire into a utility circuit.
5 English Customer Hotline 1-800-445-1805

The unit is equipped with a low oil sensor. If the oil level becomes lower than required, the sensor will activate a warning device or stop the engine.
The National Electric Code requires that this product be properly connected to an appropriate earth ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided for this purpose. Connecting a length of heavy gauge (12 AWG min.) copper wire between the generator Ground Terminal and a copper rod driven into the ground should provide a suitable ground connection. However, consult with a local electrician to insure that local codes are being adhered to.
If generator shuts off and the oil level is within specifications, check to see if generator is sitting at an angle that forces oil to shift. Place on an even surface to correct this. If engine fails to start, the oil level may not be sufficient to deactivate low oil level switch. Make sure the sump is completely full of oil.
Fill the tank with clean, fresh unleaded automotive gasoline. Regular grade gasoline may be used provided a high octane rating is obtained (at least 85 pump octane). We recommend always using a fuel stabilizer. A fuel stabilizer will minimize the formulation of fuel gum deposits during storage. The fuel stabilizer can be added to the gasoline in the fuel tank, or into the gasoline in a storage container.

Do not overfill the tank. Keep maximum fuel level 1/4 inch below the top of the fuel tank. This will allow expansion in hot weather and prevent overflow.
Do not use a pipe carrying combustible material as the ground source.
DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil. Your generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.
Fill the engine with oil according to the operator manual. For units with a dipstick, fill oil to the proper level. Units without a dipstick should be filled to the top of the opening of the oil fill.
English Customer Hotline 1-800-445-1805 6
Ground Terminal

A. Control Panel
E. Oil Warning Light
B. 120 V, 20 Ampere Receptacle 20 amps of current may be drawn from each receptacle. However, total power drawn must be kept within nameplate ratings.
F. 6.0 HP OHV Engine
G. Recoil Starter
H. Engine Choke Lever
C. Circuit Breaker The receptacles are protected by AC circuit breakers. If the generator is overloaded or an external short circuit occurs, a circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.
I. Oil Filler Cap
J. Oil Drain Plug
K. 3 Gallon Metal Fuel Tank
L. Fuel Tank Cap
M. Fuel Gauge
D. Engine On/Off Switch
N. Fuel Shut-Off

B
H
N
G
F
A
D
E
J
7 English Customer Hotline 1-800-445-1805

TOOLS REQUIRED: 10mm, 13mm, and 16mm sockets and ratchets, block(s) of wood (minimum of 6” tall). Refer to the parts list on page 37.
WHEEL INSTALLATION 1. Block up the engine end of generator to install wheel kit. 2. Insert wheel spacer (item 165) into the center of the wheel (item 166). 3. Slide M10 x 75 bolt (item 167) through the wheel (item 166), then through the wheel bracket on the carrier, with the offset side of the wheel hub against the wheel bracket. 4. Thread M10 nut (item 163) onto the bolt and tighten to securely clamp the wheel assembly to the carrier. 5. Repeat above instructions for the remaining wheel.
FOOT INSTALLATION 1. Blocking up the alternator side of the generator, assemble the rubber foot (item 161) to the carrier using a M8 x 20 bolt (item 160). Thread a M8 nut (item 162) to the bolt to secure the assembly. Caution: Do not over tighten so that the foot material collapses. 2. Repeat above instructions for the remaining foot.
HANDLE INSTALLATION 1. Place handle (item 156) on carrier on same end as feet, as shown in the diagram. 2. Slide M8 x 40 screw (item 153) through handle and handle bracket as shown in diagram and secure with M8 nyloc nut (item 155). Tighten until handle is securely clamped to the carrier. 3. Slide the handle grip (item 158) onto the handle. Slide square bolt (item 157) through handle grip as shown in diagram and secure with M6 nut (item 159). 4. Insert cap (item 154) into end of handle.
LOCKING HANDLE 1. Attach the lanyard (item 151) to the release pin (item 152) and carrier as shown in the illustration. 2. To lock the handle in the extended position, align the holes in the handle bracket with the holes in the carrier bracket and insert the release pin (item 152).


8 Customer Hotline 1-800-445-1805 English
152 151


Gasoline is very dangerous. Serious injury or death may result from fire caused by gasoline contacting hot surfaces. 1. Do not fill fuel tank with engine running. 2. Do not spill fuel while refilling tank. 3. Do not mix oil with gasoline. 4. Follow all instructions and warnings in the operator manual.
This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting will void warranty.
Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.
When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle.
This generator must not be operated without all factory installed heat shields in place. Failure to comply may cause the fuel tank to overheat and result in personal injury from fire.
STARTING THE ENGINE 1. Check oil level and fuel. 2. Disconnect all electrical loads from the unit. 3. Open fuel shut off valve. 4. Adjust choke as necessary. 5. Set the engine switch to the “ON" position. 6. Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke. On electric start models, turn the key switch to “START”. Release key switch after the engine starts.
Do not apply heavy electrical load during break-in period (the first two to three hours of operations).

SHUTTING THE GENERATOR OFF 1. Remove entire electrical load. 2. Let the engine run for two minutes without load. 3. Move the engine switch to the “OFF” position. (Turn the key switch to “OFF” on the electric start models). 4. Do not leave the generator until it has completely stopped. 5. Close the fuel shut off valve if the engine is to be put in storage or transported. 6. If a cover is used, do not install until unit has cooled.
Allow generator to run at no load for five minutes upon each initial start-up to permit engine and generator to stabilize.
Customer Hotline 1-800-445-1805 9 English

ITEM NOTES Daily (Before operation)
Initial 20 hours Every 50 hours Every 100 hours
Engine Oil Check oil level. ü Replace. ü ü Air Filter Clean, replace if necessary. ü
Fuel Filter Clean fuel filter and fuel tank strainer. Replace if necessary. ü
Fuel Line Check fuel hose for cracks or other damage. Replace if necessary. ü
Check muffler screen. Clean/replace if necessary. ü
Carburetor Check choke operation. ü Starting System Check recoil starter operation. ü
Fittings/ Fasteners Check. Replace if necessary. ü
OIL REPLACEMENT 1. Change oil while engine is warm. 2. Place the generator unit on a level surface. 3. Remove the oil filler cap. 4. Open the oil drain plug and let oil drain completely into a pan placed under the engine. 5. Check gaskets. Replace if required. 6. Reinstall the oil drain plug and refill engine with clean oil. 7. Replace the oil filler cap.
Remove the spark plug and clean the electrodes section with a wire brush or sandpaper. Next, set the gap at .028/.031 inches (0.7-0.8 mm) by adjusting the negative electrode. Replace the spark plug with correct torque: 14 ft-lb (20 N.m)
AIR FILTER CLEANING 1. Unscrew the air filter cover. 2. Remove filter element and wash well in solvent. 3. Pour a small amount of oil onto the filter element and gently squeeze out any excess oil. 4. Replace the filter element and air filter cover. 5. Be sure the filter cover seals properly all around.
Replace with only the same type of spark plug which was removed. An improper spark plug can cause the engine to overheat, emit smoke, or otherwise perform poorly.
Use new good quality oil, SE, SF, or SD grade. The oil to be used depends upon the temperature at which the engine is operated:
FUEL VALVE FILTER CLEANING 1. Remove the cup at the bottom of the fuel valve with a small wrench. 2. Remove the fuel valve filter. 3. Clean and wash out the filter and cup and replace.
Below 32° F (0° C) SAE 10W, 10W-30, or 10W-40 32 to 80° F (0 to 25° C) SAE 20W, 10W-30, or 10W-40 80 to 95° F (25 to 35° C) SAE 30W, 10W-30, or 10W-40 Above 95° F (35° C) SAE 40W
FUEL STRAINER CLEANING 1. Remove the plastic fuel strainer, located below the fuel tank cap. 2. Wash the strainer in solvent and replace.
Customer Hotline 1-800-445-1805 10 English
Exhaust System


ENGINE SPECIFICATIONS
Type 4-stroke, single cylinder, gasoline, OHV Displacement 193 cc, 11.78 cubic inches Maximum HP 6.0 HP @ 3600 rpm Starting System Recoil (electronic ignition) Driving System Direct coupling, tapered crank Oil Capacity 20 oz. Spark Plug Champion RN14YC or equivalent Governor Mechanical (adjustable) Cooling System Forced air cooling Bore x Stroke 66.0 X 50.0 mm (2.60 x 1.97 in.) Carburetor Type Float Air Cleaner Type Foam element
English

Warranty Coverage: Powermate Corporation (the Company) warrants to the original retail customer in North America that it will repair or replace, free of charge, any parts found by the Company or its authorized service representative to be defective in material or workmanship. This warranty covers the cost of replacement parts and labor for defects in material or workmanship.
POWERMATE CORPORATION
PRODUCT SERVICE
Not Covered: · Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer. · If a separate operator's manual and engine warranty from the engine manufacturer is included with this product, only that warranty will apply to the engine. · Damages caused by abuse or accident, and the effects of corrosion, erosion and normal wear and tear. · Warranty is voided if the customer fails to install, maintain and operate the product in accordance with the instructions and recommendations of the Company set forth in the owner's manual, or if the product is used as rental equipment. · The Company will not pay for repairs or adjustments to the product, or for any costs or labor, performed without the Company's prior authorization.
1-800-445-1805
to obtain warranty service
information or to order
replacement parts or
accessories.
Even quality built equipment such as the electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the following information:
Warranty Period: One (1) year from the date of purchase on products used solely for consumer applications; if a product is used for business or commercial applications, the warranty period will be limited to ninety (90) days from the date of purchase. For warranty service, the customer must provide dated proof of purchase and must notify the Company within the warranty period.
For warranty service: Call toll free 800-445-1805, or write to Powermate Corporation, Product Services, 4970 Airport Road, P. O. Box 6001, Kearney, NE 68848.
EXCLUSIONS AND LIMITATIONS: THE COMPANY MAKES NO OTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY DISCLAIMED. THE WARRANTY SERVICE DESCRIBED ABOVE IS THE EXCLUSIVE REMEDY UNDER THIS WARRANTY; LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES IS EXCLUDED TO THE EXTENT PERMITTED BY LAW.
4970 Airport Road P. O. Box 6001 Kearney, NE 68848
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow a disclaimer of implied warranties, or the exclusion or limitation of incidental and consequential dam- ages, so the above disclaimers and exclusions may not apply to you.
Customer Hotline 1-800-445-1805 13 English
Powermate Corporation · 1-800-445-1805


Type A quatre temps, à un cylindre, à essence, OHV Cylindrée 193 cc CV maximum 6.0 cv à 3600 tr/min Système de démarrage A détente (allumage électronique) Système de propulsion Accouplement direct, bilegrequin effilé Capacité d’huile 20 oz Bougie Champion RN14YC ou l’équivalent Régulation Mécanique (ajustable) Système de refroidissement Refroidissement à air forcé Alésage x course 66,0 x 50,0 mm Type de carburateur A flotteur Type filtre Elément en mousse
Français Assistance Téléphonique 1-800-445-1805
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.