Safety precautions are essential when any mechanical equipment is involved. These precautions are necessary when using, storing, and servicing mechanical equipment. Using this equipment with the respect and caution demanded will considerably lessen the possibilities of personal injury. If safety precautions are overlooked or ignored, personal injury or property damage may occur.
The following symbols shown below are used extensively throughout this manual. Always heed these precautions, as they are essential when using any mechanical equipment.
This warning symbol identifies specific instructions or procedures which if not correctly followed could result in personal injury or death.
This caution symbol identifies specific instructions or procedures which, if not strictly observed, could result in damage to, or destruction of equipment.
This unit was designed for specific applications. It should not be modified and/or used for any application other than which it was designed. If there are any questions regarding its application, write or call Customer Service at 1-800-445-1805.
When using this product basic precautions should always be followed, including the following:
13. The generator should be operated, serviced, and refueled only under the following conditions: a. Good ventilation - avoid areas where vapors may be trapped such as pits, basements, cellars, excavations, and boat bilges. Air flow and temperatures are important for air cooled units. Temperatures should not exceed 100 degrees F (40 degrees C). b. Dangerous exhaust gases should be piped from enclosed areas. The engine exhaust contains carbon monoxide, a poisonous, odorless, invisible gas which, if breathed, causes serious illness and possible death. c. Refuel the generator in a well lighted area. Avoid fuel spills and never refuel while the generator is running. Allow engine to cool for two minutes prior to refueling. d. Do not refuel near open flames, pilot lights, or sparking electrical equipment such as power tools, welders, and grinders. e. The muffler and air cleaner must be installed and in good condition at all times as they function as flame arresters if backfiring occurs. f. Do not smoke near the generator.

In order to prevent overloading and possible damage to your generator it is necessary to know the total wattage of the connected load. To determine which tools and/or appliances your generator will run follow these steps:

CAUTION: Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator. Damage may result if the equipment is not designed to operate within a +/- 10% voltage variation, and +/- 3 hz frequency variation from the generator name plate ratings. To avoid damage, always have an additional load plugged into the generator if solid state equipment (such as a television set) is used. A power line conditioner may also be necessary for some solid state applications.
THIS PRODUCT IS NOT EQUIPPED WITH A SPARK ARRESTING MUFFLER. If the product will be used around flammable materials, such as agricultural crops, forests, brush, grass, or other similar items, then an approved spark arrester should be installed and is legally required in the State of California. The California statutes requiring a spark arrester are Sections 13005(b), 4442 and 4443. Spark Arresters are also required on some U.S. Forest Service land and may also be legally required under other statutes and ordinances. An approved spark arrester is available from your Coleman Powermate dealer, or may be ordered from Coleman Powermate, Inc., P.O. Box 6001, Kearney, Nebraska 68848. 1-800-445-1805.
Typical example of solid state equipment include:
Garage door openers Kitchen appliances with digital displays Televisions Stereos Personal computers Quartz clocks Copy machines Telephone equipment
For more information, contact our Customer Service Department at 1-800-445-1805.

STARTING THE ENGINE 1. Check oil level and fuel. 2. Disconnect all electrical loads from the unit. 3. Open fuel shut off valve. 4. Adjust choke as necessary. 5. Set the engine switch to the “ON" position. 6. Pull on the starter rope with fast steady pull. As the engine warms up, readjust the choke. On electric start models, turn the key switch to “START”. Release key switch after the engine starts.
Make sure that the generator is grounded to help prevent accidental shock. A ground lug has been provided for this purpose. Connect a length of heavy gauge wire between the generator lug and an external ground source, such as a water pipe or copper rod driven into the ground.

Controlled break-in helps insure proper engine and generator operation. Follow engine procedure outlined in engine manual.
DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil. (See the accompanying engine manual for this information.) Your generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine.
SHUTTING THE GENERATOR OFF 1. Remove entire electrical load. 2. Let the engine run for a few minutes without load. 3. Move the engine switch to the “OFF” position. (Turn the key switch to “OFF” on the electric start models). 4. Do not leave the generator until it has completely stopped. 5. Close the fuel shut off valve if the engine is to be put in storage or transported. 6. If cover is used, do not install until unit has cooled.
Fill the tank with clean, fresh unleaded automotive gasoline. Regular grade gasoline may be used provided a high octane rating is obtained (at least 85 pump octane).
Refer to the appropriate diagram for proper connection of power cord wires to the plug terminals.

Before starting the generator, check for loose or missing parts and for any damage which may have occurred during shipment.
120 Volts, 30 Ampere Plug
Ground Lug


A. 120 V, 15 or 20 Ampere Duplex Receptacle This duplex is split (except on the 7000 watt units) so that 15/20 amps of current may be drawn from each half of the receptacle. However, total power drawn must be kept within nameplate ratings. These receptacles may be used along with the twistlock receptacle provided the generator is not overloaded.
B. 120 V, 30 Ampere Twistlock Receptacle You may draw a maximum of 30 amps or 3600 watts from this receptacle. If other receptacles are used at the same time, total power used must be kept within nameplate ratings.
120/240 Volts, 20 Ampere and 30 Ampere Plug

C. 120/240 V, 20 Ampere Twistlock Receptacle A maximum of 20 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.
D. Circuit Breakers The receptacles are protected by an AC circuit breaker. (See Circuit Protection).
E. Idle Control Switch Some models are equipped with an idle control switch. (See Idle Control).
240 Volts, 50 Ampere Plug
This unit has been pretested and adjusted to handle its full capacity. When starting the generator, disconnect all load. Apply load only after generator is running. Voltage is regulated via the engine speed adjusted at the factory for correct output. Readjusting is not advised.
F. 120/240 V 30 Amp Twistlock Receptacle A maximum of 30 amps may be drawn from the 120/240 volt receptacle, provided it is the only receptacle used. However, current must be limited to the nameplate rating. If the 120/240 volt receptacle is used along with the 120 volt receptacle, the total load drawn must not exceed the nameplate ratings.
H. DC Receptacle 12 V, 15 Ampere Some models are equipped with a battery charger. (See DC Features).
I. 120 Volt GFCI Receptacle Ground Fault Circuit Interrupter duplex receptacle is rated so that a total of 20 amps may be drawn regardless of whether both halfs or just one receptacle is used. This receptacle may be used along with the other receptacles provided the generator is not overloaded and total power drawn is kept within nameplate ratings. Ground Fault Circuit Interrupter (Conforms to U.L. 943, Class A and NEC requirements) This device protects you against hazardous electrical shock that may be caused if your body becomes a path through which electricity travels to reach ground. This could happen when you touch an appliance or cord that is “live” through faulty mechanism, damp or worn insulation, etc.
J. 240 Volt Heavy Duty Receptacle This receptacle is rated at 50 amps but the current must be limited to the nameplate rating. If this receptacle is used along with the 120 volt receptacles, the total load drawn must not exceed the nameplate ratings.
K. Engine Start/Stop Switch


The receptacles are protected by an AC circuit breaker. If the generator is overloaded or an external short circuit occurs, the circuit breaker will trip. If this occurs, disconnect all electrical loads and try to determine the cause of the problem before attempting to use the generator again. If overloading causes the circuit breaker to trip, reduce the load. NOTE: Continuous tripping of the circuit breaker may cause damage to generator or equipment. The circuit breaker may be reset by pushing the button of the breaker.
PM0473503, PL0473503 & PC0473503 Control Panel
DC FEATURES (Models PM0473503, PL0473503 & PC0473503 Only) Battery Charger
This generator contains a circuit used for battery charging purposes. A two-prong DC receptacle is provided for this feature. A battery charging cable equipped with a matching plug for this receptacle has been supplied with the unit.

The battery charger on the generator is referred to as an unregulated taper charger, the most widely used in the market today. The amount of current flowing will depend on the charging voltage and battery’s state of charge. As the on- charge output current to the battery decreases, the output current to the battery increases and nearly becomes constant. Taper chargers are intended to be used with the provision that they will be disconnected from the battery after maximum time on charge. Normally a period of 30 to 120 minutes is sufficient to recharge a weak battery.

PM0475003 & PC0475003 Control Panel
Before charging a storage battery, check the electrolyte fluid level in all the cells. (Sealed batteries do not require checking). Add distilled water to each cell, if necessary, to bring the level back up to the manufacturer’s required level.

Connect the red clip to the positive terminal of the battery. Connect the black clip to the negative terminal of the battery. Insert the DC plug into the DC receptacle to the generator. After the battery is fully charged remove the battery charging cable from the generator and then disconnect from the battery posts.
PM0477022, PM0477023 & PC0477023 Control Panel

PM0474203 Control Panel · PM0478022 Control Panel



BASIC WIRING DIAGRAM Electric Start Models (Models with Key Switch on Panel)


The Idle Control circuit is designed to extend engine life and improve fuel usage by slowing the engine down to approximately 2000 RPM in a “No Load” condition. The noise is also greatly reduced during this condition.
When power is required from the generator an electronic control module automatically senses current flow in the electrical outlet and allows the engine to return to full speed or standard operating condition. Likewise, when the load is removed, the generator will automatically return to the idle condition after a 4-5 second delay.
A convenient switch is mounted in the control panel for easy access and will disable the Idle Control circuitry when in the off position.

The brushes in the generator should be inspected once every year for chips and cracks. Brushes should be replaced when they are worn to 1/4 inch (7mm).
INSPECTING THE BRUSHES: 1. Remove cover plate (L). 2. Remove 4 stator bolts (O) and endbell. 3. Disconnect the green (-) or blue (+) brush wires from the tab. 4. Remove brush mounting screws (M). 5. Slide brushes (N) from holders. 6. Replace if worn to 1/4 inch (7mm). 7. Do not over tighten screws.

to obtain warranty service
information or to order
replacement parts or
accessories.
Even quality built equipment such as the Coleman Powermate electric generator you have purchased, might need occasional replacement parts to maintain it in good condition over the years. To order replacement parts, please give the following information:
If there is a loss of residual magnetism (voltage will not build up), it may be necessary to re-excite the unit.

Coleman Powermate, Inc.
4970 Airport Road P. O. Box 6001 Kearney, NE 68848
Inspect to ensure that all heat shields and heat deflectors are intact and in place.
During the winter months, rare atmospheric conditions may develop which will cause an icing condition in the carburetor. If this develops, the engine may run rough, loose power, and may stall. This temporary condition can be overcome by deflecting some of the hot air from the engine over the carburetor area.

This product is warranted by Coleman Powermate, Inc. to the original retail consumer against defects in material and workmanship for a period of two (2) years from the date of retail purchase and is not transferable. This two year warranty applies only to products used in consumer applications. If these generators are used in a commercial application, then the period of warranty coverage is limited to one (1) year from the date of purchase.
Please complete and return the enclosed Customer Information Card so that we can reach you in the unlikely event a safety recall is needed. Return of this card is not required to validate this warranty.
WHAT IS COVERED: Replacement parts and labor.
WHAT IS NOT COVERED: Transportation charges to Coleman Powermate, Inc. for defective products. Transportation charges to consumer for repaired products. Brushes, rubber feet, and receptacles. Damages caused by abuse, accident, improper repair, or failure to perform normal maintenance. Power units or engines which are covered exclusively by the warranties of their manufacturer. Sales outside of the United States and Canada. Any other expense including consequential damages, incidental damages, or incidental expenses, including damage to property. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
IMPLIED WARRANTIES: Any implied warranties, including the Implied Warranties of Merchantability and Fitness For A Particular Purpose, are limited in duration to one (1) year from the date of retail purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
HOW TO OBTAIN WARRANTY PERFORMANCE: Replacement parts and service are available from Coleman Powermate, Inc. Service Centers. Locate your nearest Service Center by calling TOLL FREE 1-800-445-1805. In the unlikely event a Service Center can not be located you may call Coleman Powermate, Inc. for a return authorization number. Any unit returned WITHOUT an authorization number will be refused.
To the extent any provision of this warranty is prohibited by federal, state, or municipal law, and cannot be preempted, it shall not be applicable. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Unit will not idle | Control panel switch not on | Turn to idle on position | p.8 |
| Unit will not idle | Load plugged into receptacle | Unplug load | p.8 |
| Unit will not idle | Poor connection or faulty cord | Check & repair | p.8 |
| Unit will not idle | Bad I.C. module; Bad electro-magnet or solenoids; Bad stator | Replace | p.8 |
| Unit will not idle | Consult dealer | p.8 | |
| Unit idles even with load plugged in | Load not heavy enough | Turn idle switch to off position | p.8 |
| Unit idles even with load plugged in | Increase load | p.8 | |
| Unit idles even with load plugged in | Bad I.C. module | Replace | p.8 |
| Unit idles even with load plugged in | Consult dealer | p.8 | |
| Unit tries to idle but won’t stay latched | Electro-magnet or solenoid position incorrect | Reset magnet or solenoid position for 2000 RPM idle speed | p.8 |
| Unit tries to idle but won’t stay latched | Consult dealer | p.8 | |
| Unit tries to idle but won’t stay latched | Flapper bracket loose or bent | Tighten or straighten | p.8 |
| Unit tries to idle but won’t stay latched | Replace flapper. Readjust to 2000 RPM | p.8 | |
| Unit tries to idle but won’t stay latched | Engine not running smoothly | Adjust carburetor | p.8 |