EN
Planet Technology logo
Official user manual

Planet Technology VC-412

46 pages·1.1 MB·Switch·PDF·ENDEFRITNLJA
Planet Technology VC-412
Table of Contents 46 sections 1. INTRODUCTION · 1.1 Feature · 1.2 VC-412 Technical Specifications · 1.3 Package Contents & Hardware Description · … ShowHide
Page 1 of the Planet Technology VC-412 user manual — User’s Manual
Page 1 · click to enlarge
Page 1

Intelligent Ethernet over VDSL

Switch

Planet Technology VC-412 — Intelligent Ethernet over VDSL diagram (page 1)
Fig. 1 · Intelligent Ethernet over VDSL

User’s Manual

Page 2 of the Planet Technology VC-412 user manual — Revision
Page 2 · click to enlarge
Page 2

Trademarks

Copyright PLANET Technology Corp. 2002. Contents subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

CE Mark Warning

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

Revision

PLANET Intelligent Ethernet over VDSL Switch User's Manual For Model: VC-412 Part No.: EM-VC412V1

FCC Warning

Page 3 of the Planet Technology VC-412 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

1. INTRODUCTIONp.51.1 Featurep.51.2 VC-412 Technical Specificationsp.61.3 Package Contents & Hardware Descriptionp.71.4 LED Indicators And Button Definitionp.82. INSTALLATIONp.102.1 Connecting VC-412p.102.2 Console Port Setupp.112.3 Telnet Setupp.133. WEB CONFIGURATIONp.143.1 Web configuration setupp.143.2 Monitor Configurationp.163.2.1 Unit Informationp.163.2.2 Port Informationp.163.2.2.1 VDSL PORT Informationp.163.2.2.2 TRUNK PORT INFORMATIONp.173.3 System configurationp.173.3.1 System Configurationp.173.3.2 Reset To Defaultp.183.4 Network Configurationp.193.4.1 Protocol Controlp.193.4.2 SNMP Access Tablep.203.4.3 SNMP Trap Receiver Tablep.214. COMMANDS FOR CONSOLE AND TELNETp.234.1 Main Menu Selectionsp.234.2 Management Configurationp.234.2.1 System Configurationp.244.2.2 Network Configurationp.264.2.3 System MIB Configurationp.284.3 SNMP Access Table/SNMP Trap Receive Control Tablep.294.4 VDSL Unit Controlp.304.4.1 Pass-Through ICD Command to Unitp.304.4.2 Set Each VDSL Port Name of Unitp.304.4.3 Display All Ports Status of Unitp.314.4.4 Display All Trunks Status of Unitp.324.5 Reset To Defaultp.334.6 Reboot Systemp.334.7 Logoutp.345. ICD COMMANDS FOR TELNET AND CONSOLEp.355.1 Enter ICD command line interfacep.355.2 ICD command Index Tablep.365.3 Setting VLAN Functionalityp.385.4 VDSL Commandp.405.5 Port Commandp.41APPENDIX A – VC-412 FACTORY DEFAULTp.43APPENDIX B – UPDATE VC-101S FIRMWARE TO R4.5 REMOTELY THROUGH VC-412p.44
Page 4 of the Planet Technology VC-412 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

1. INTRODUCTIONp.51.1 Featurep.51.2 VC-412 Technical Specificationsp.61.3 Package Contents & Hardware Descriptionp.71.4 LED Indicators And Button Definitionp.82. INSTALLATIONp.102.1 Connecting VC-412p.102.2 Console Port Setupp.112.3 Telnet Setupp.133. WEB CONFIGURATIONp.143.1 Web configuration setupp.143.2 Monitor Configurationp.163.2.1 Unit Informationp.163.2.2 Port Informationp.163.2.2.1 VDSL PORT Informationp.163.2.2.2 TRUNK PORT INFORMATIONp.173.3 System configurationp.173.3.1 System Configurationp.173.3.2 Reset To Defaultp.183.4 Network Configurationp.193.4.1 Protocol Controlp.193.4.2 SNMP Access Tablep.203.4.3 SNMP Trap Receiver Tablep.214. COMMANDS FOR CONSOLE AND TELNETp.234.1 Main Menu Selectionsp.234.2 Management Configurationp.234.2.1 System Configurationp.244.2.2 Network Configurationp.264.2.3 System MIB Configurationp.284.3 SNMP Access Table/SNMP Trap Receive Control Tablep.294.4 VDSL Unit Controlp.304.4.1 Pass-Through ICD Command to Unitp.304.4.2 Set Each VDSL Port Name of Unitp.304.4.3 Display All Ports Status of Unitp.314.4.4 Display All Trunks Status of Unitp.324.5 Reset To Defaultp.334.6 Reboot Systemp.334.7 Logoutp.345. ICD COMMANDS FOR TELNET AND CONSOLEp.355.1 Enter ICD command line interfacep.355.2 ICD command Index Tablep.365.3 Setting VLAN Functionalityp.385.4 VDSL Commandp.405.5 Port Commandp.41APPENDIX A – VC-412 FACTORY DEFAULTp.43APPENDIX B – UPDATE VC-101S FIRMWARE TO R4.5 REMOTELY THROUGH VC-412p.44
Page 5 of the Planet Technology VC-412 user manual — 1.1 Feature
Page 5 · click to enlarge
Page 5

1. INTRODUCTION

Thank you for choosing the VC-412 VDSL Managerial Switch for your MDU Solution.

PLANET has been on the forefront of VDSL (Very High Bit-Rate Digital Subscriber Line)

technologies since their inception, and will always strive to create quality, cost-effective

solutions for VDSL users and installers.

Fiber all the way to the home (FTTH) is very expensive therefore another alternative is a

combination of fiber cables to Optical Network Units (ONUs) or otherwise called the Fiber

to the Neighborhood (FTTN) as the connection point between fiber and existing or new

copper wire. One of the enabling technologies for FTTN is Very high rate Digital

Subscriber Line, or VDSL. In simple terms, VDSL transmits high speed data over short

reaches of twisted-pair copper telephone lines, with a range of speeds depending upon

actual line length.

By choosing the VC-412 VDSL Managerial Switch, you have enabled your network to

have the superb speed and manageability. VC-412 offers 12 VDSL ports, 12 POTS/ISDN

ports and 4 Ethernet ports for your VDSL solutions.

1.1 Feature

Some VC-412 highlights include:

z Twelve (12) VDSL ports

z Twelve (12) POTS/ISDN ports

z Four (4) 10/100 Mbps Ethernet ports

z One (1) Local management Console port

z Supports security with port based VLAN function

z Virtual LAN (VLAN) Grouping

z Frequency division multiplexing for uninterrupted simultaneous voice/data

z Layer 2 Switching.

z Support Telnet, Web-Based, Console and SNMP Interfaces

z Ethernet ports status monitoring

z Management Information Base (MIB) Settings

transmission · z Store-and-Forward mechanism

Page 6 of the Planet Technology VC-412 user manual — 1.2 VC-412 Technical Specifications
Page 6 · click to enlarge
Page 6

z Back Pressure and IEEE 802.3x compliant flow control

z Supports 8K MAC addresses entries

z 1 MB Buffer Memory

z Back Pressure flow control for half-duplex

z PAUSE Frame flow control for full-duplex (802.3x)

1.2 VC-412 Technical Specifications

„ SNMP/MIB-II/RFC1213

„ Firmware upgradeable through TFTP

„ Telnet/Console/Web-Based/SNMP interfaces management support

„ Supports four languages (English, Traditional Chinese, Simplified Chinese,

„ Standard based SNMP, MIB-II and proprietary MIBs

„ Supports TCP/IP, SNMP, HTTP, TFTP, DHCP, BOOTP, Telnet protocols.

z Twelve (12) VDSL Ports and Twelve (12) POTS/ISDN Ports

„ LEDSync, Activity, Error

„ Maximum Distance – 1.5 km

z Four (4) Ethernet Ports

„ 10/100 Mbps, Auto-Negotiation

„ IEEE 802.3, 802.3u, 802.3x

„ LEDLink/Activity, 10/100, Full Duplex/Collision

z One (1) Console Port

„ Baud Rate19200 bps, 8 Data Bits, 1 Stop Bit, No Parity, No Flow Control

„ For VC-412 Local Console management

z Physical Specifications:

„ AC Input100 - 250 VAC, 47 - 63 Hz, Internal Universal Power Supply

„ Power Consumption: 60W Max / 205 BTU Max.

Show 4 more labels / short text on this page
z Management Features · „ In-Band/Out-Band management · Japanese) · z SNMP Management
Page 7 of the Planet Technology VC-412 user manual — 1.3 Package Contents & Hardware Description
Page 7 · click to enlarge
Page 7
„ Operating Temperature32 to 122 ° F (0 to 50 ° C)
„ Storage Temperature-13 to 158 ° F (-25 to 70 ° C)
„ Humidity10% - 90% Non-Condensing
„ CertificationFCC, VCCI, CE
„ Net Weight4.16 kg
„ Dimensions446 × 300 × 44 mm

1.3 Package Contents & Hardware Description

Upon opening your package you should have the following items:

  • (1) Power Cord
  • (1) VC-412 Intelligent VDSL Switch
  • (1) RS232 Male Console Cable (DB9 to DB9)
  • (1) Setup and Installation Manual CD
  • (1) Quick Installation Guide

If any of these items are missing, please contact your vendor immediately before

continuing. For additional manuals please contact your vendor.

Before removing the switch from the package please ensure to remove all static devices

and static electricity from your body by touching an available metal plate or grounding

point.

Your new VC-412 has 12 VDSL ports, 12 POTS/ISDN ports, 4 Ethernet ports and 1 Local

Console (RS232) port.

Planet Technology VC-412 — 1.3 Package Contents & Hardware Description diagram (page 7)
Fig. 2 · 1.3 Package Contents & Hardware Description
Page 8 of the Planet Technology VC-412 user manual — 1.4 LED Indicators And Button Definition
Page 8 · click to enlarge
Page 8

1.4 LED Indicators And Button Definition

Planet Technology VC-412 — 1.4 LED Indicators And Button Definition diagram (page 8)
Fig. 3 · 1.4 LED Indicators And Button Definition
Planet Technology VC-412 — 1.4 LED Indicators And Button Definition diagram (page 8)
Fig. 4 · 1.4 LED Indicators And Button Definition
LEDFunctionColorStatusDescription System Status POWERPower indicationGreenOnSystem is turned on OffSystem is off VLANVLAN statusGreenOnVLAN or VLAN grouping is on OffVLAN off ALARMReserved------ Ethernet Port LNK/ACTEthernet port Link/ActiveGreenOnLink no data transmit BlinkingLink and transmitting data (active) OffNo Ethernet link 100Ethernet port transmit and receive speedGreenOnThe speed is 100Mbps OffThe speed is 10Mbps FDX/COLEthernet port duplex modeYellowOnFull Duplex OffHalf duplex no collision BlinkingHalf duplex and transmission collisions have occurred VDSL Ports SYNCVDSL linkGreenOnVDSL link is established OffNo VDSL link ACTVDSL activeGreenOnTransmitting data OffNot transmitting data ERRErrors on lineYellowOnErrors occurred on the line OffNo error
Page 9 of the Planet Technology VC-412 user manual — 1.4 LED Indicators And Button Definition
Page 9 · click to enlarge
Page 9
ButtonFunction ResetPush to reboot the switch Normal / UplinkNormal: When connect port D to PC or other end nodes. Uplink: When connect port D to other switch or hub.
Page 10 of the Planet Technology VC-412 user manual — 2.1 C onnecting VC-412
Page 10 · click to enlarge
Page 10

2. INSTALLATION

2.1 C onnecting VC-412

The VC-412 has the ability to provide up to 12 remote VDSL connections. The VC-412

serves as a VDSL Managerial Switch, it can connect up to 12 sets of PLANET remote

VDSL modems such as the VC-101S.

The VC-412 connects to the PBX through the POTS/ISDN ports to provide telephone

services to the remote ends. The VC-412 VDSL ports then connect to the remote VDSL

modems via telephone wires with a maximum distance up to 1.5 km.

The VC-412 takes approximately 15 seconds to start, therefore when connecting the

VC-412 to a remote modem such as the VC-101S, it will take 15 seconds for link to be

established.

VC-412 Ethernet Port-D can serve as an uplink or a regular Ethernet port on, when the

Uplink button is pressed down it serve as an uplink port, when the Uplink button is

released it serve as a regular Ethernet port. Hence when connecting the VC-412 to

WAN via regular Cat. 5 cable on Port-D press down the Uplink button.

Page 11 of the Planet Technology VC-412 user manual — 2.2 C onsole Port Setup
Page 11 · click to enlarge
Page 11
Planet Technology VC-412 — 2.2 Console Port Setup diagram (page 11)
Fig. 5 · 2.2 Console Port Setup

2.2 C onsole Port Setup

Page 12 of the Planet Technology VC-412 user manual — 2.2 Console Port Setup
Page 12 · click to enlarge
Page 12

The VC-412 contains a powerful management interface accessible through the Console

Port. This section will discuss connecting to the switch through Console Port or Telnet.

For connection to the VC-412 via the console port, you must use the included DB-9 to

DB-9 cable.

Once out of the box and powered on, you must use the Console Port to setup the switch core settings. Some of the basic settings include:

  • Switch Management Module IP Address
  • Gateway Address
  • Subnet Mask
  • Password Settings

To setup Console connection, use the DB9-to-DB9 cable to connect the VC-412 Console

port to PC COM port.

Once the VC-412 Console port is connected to the PC COM port, start any terminal

application. Subsequently, configure the terminal application settings with following

variables:

Baud RateData BitsParityStop BitsFlow Control 19200bps8None1None

Once connected, password authentication is required. The default password is admin.

Console and Telnet share similar interfaces, the main difference between them is that

Console connects to the Switch directly through a cable. Telnet connects to the switch

remotely via an IP Address. Therefore, to use Telnet to access to the Switch, you will first

need to assign a valid IP address to the Switch through the Console. Otherwise use the

factory default IP address listed in the Appendix A. Web-Based interfaces also required

the same Switch IP, however the interfaces are different from Console and Telnet. (This

will be discussed in the Chapter 3.)

To assign an IP address to the Switch:

1. Select Management Configuration option from the Main Menu. 2. Select System Configuration option from the Submenu. 3. Select IP Address option. 4. Enter valid IP address. 5. When setting up Gateway Address and Subnet Mask repeat Step 2 and select

the appropriate option in the menu. Refer to your network administrator for your

appropriate Gateway Address and Subnet Mask.

Page 13 of the Planet Technology VC-412 user manual — 2.3 T elnet Setup
Page 13 · click to enlarge
Page 13

Once you have assigned a valid IP address to the Switch, proceed to chapter 4 for an

explanation of the menu systems and commands.

2.3 T elnet Setup

Once you have setup the switch IP address via the Console Port, you are ready to access

the management functions from any station on your network via Telnet. To connect,

simply start your telnet client and enter the address you configured into the switch

(Device IP Address). Below you can see an example of using the standard Windows®

Telnet client. Before using Telnet, you must first know your Switch device IP address. The

IP should have been set earlier in the Console setup section. If the IP address has not yet

been set, refer to the quick installation guide.

For Windows 95/98/NT/2000/XP:

A. Press on Start Menu, then on RUN, type in telnet and the device IP address. For

example, if the IP address is 192.168.0.1, type “telnet 192.168.0.1” and hit enter.

B. Connection will initiate and you will be prompt to enter password.

C. The default password is admin, unless it has been changed previously.

Once you have logged into the switch, proceed to the next section for an explanation on

issuing ICD commands.

Page 14 of the Planet Technology VC-412 user manual — 3.1 Web configuration setup
Page 14 · click to enlarge
Page 14

3. WEB CONFIGURATION

3.1 Web configuration setup

Configuration through Web browser interface is a fast and convenient way. Although

this is an easy method, you do not have the full flexibility and control granted as you

would under Telnet or Console. The HTTP interface allows basic functions, such as Reset

Unit Counters. However, we recommend users to perform modifications through Console

or Telnet interfaces. The Web browser interface also allows VDSL ports and Ethernet

(trunk) ports monitoring, providing feedback on network statuses.

To log on to the VC-412 via HTTP you must first provide the IP address to the VC-412.

The IP address should have been set earlier in the Console setup section. If your IP has

not been set, please refer to the Console port section or the Defaults section in the

Appendix A.

A. Launch your Web browser.

B. Enter the corresponding VDSL Managerial Switch IP Address in the address

field and press Enter.

C. You will be able to select your language preferences in the upper-right corner.

Selections areEnglish, Traditional Chinese, Simplified Chinese and

Japanese respectively.

D. Press the Become Administrator button if you want to access to administrator

options.

Page 15 of the Planet Technology VC-412 user manual — 3. WEB CONFIGURATION
Page 15 · click to enlarge
Page 15
Planet Technology VC-412 — 3. WEB CONFIGURATION diagram (page 15)
Fig. 6

E. A password dialog will appear prompting for username and password. The

default username is VDSL and password is admin, unless it has been

changed previously in the preliminary setup.

Planet Technology VC-412 — 3. WEB CONFIGURATION diagram (page 15)
Fig. 7

administrator can turn off the browse option (this will be discussed in later). Set

Value option is not available without entering the correct username and password.

Administrators will need to close browser to log out of administrator page.

Page 16 of the Planet Technology VC-412 user manual — 3.2.2 Port Information
Page 16 · click to enlarge
Page 16

3.2 Monitor Configuration

3.2.1 Unit Information

After the correct username and password are entered, you will be redirected to an

administrator page. On this particular screen you will be able to see the Virtual LAN

status. This window also contains the serial number information of the units. However, the

only adjustable value this panel is the Reset Unit Counter option. This option will reset the

Receive, Send and Collision counters for the unit. Select the check box and press the Set

Value button will reset the unit counter.

Planet Technology VC-412 — 3.2 Monitor Configuration diagram (page 16)
Fig. 8 · 3.2 Monitor Configuration

3.2.2 Port Information

3.2.2.1 VDSL PORT Information

Under the VDSL Port Information, you will find a representation of the switch LED to

indicate activity, collision, link etc. Administrator is also able to enable or disable port by

selecting or deselecting the check box under Enable option. Administrator may also

rename the ports by typing over the existing names.

Page 17 of the Planet Technology VC-412 user manual — 3.3 System configuration
Page 17 · click to enlarge
Page 17
Planet Technology VC-412 — 3.2.2.2 TRUNK PORT INFORMATION diagram (page 17)
Fig. 9

3.2.2.2 TRUNK PORT INFORMATION

Under this section you will be able to monitor the Ethernet Link, Active and Collision LEDs. A green signal in the LED columns represents active status in the corresponding port and column.

Planet Technology VC-412 — 3.2.2.2 TRUNK PORT INFORMATION diagram (page 17)
Fig. 10

3.3 System configuration

3.3.1 System Configuration

You will also notice the System link at the top frame, select this link to change the system

Page 18 of the Planet Technology VC-412 user manual — 3.3.2 Reset To Default
Page 18 · click to enlarge
Page 18

settings of the switch such as refresh time (the rate at which the monitoring screen

refreshes itself to report back statuses) and IP Address. The System Configuration

screen is illustrated below; the settings are self-explanatory.

Planet Technology VC-412 — 3.3.2 Reset To Default diagram (page 18)
Fig. 11 · 3.3.2 Reset To Default

3.3.2 Reset To Default

Also available under the System Link is the Reset to Default. Reset to Default option will

clear the VC-412 settings, then restore the initial factory settings to it.

Planet Technology VC-412 — 3.3.2 Reset To Default diagram (page 18)
Fig. 12 · 3.3.2 Reset To Default
Page 19 of the Planet Technology VC-412 user manual — 3.4 Network Configuration
Page 19 · click to enlarge
Page 19

3.3.3 Reboot System

Reboot System option reboots the VC-412 when it seems to be malfunctioning. It will not

reset or change any settings. Select the option from the drop-down menu and press the

Set Value button.

Planet Technology VC-412 — 3.3.3 Reboot System diagram (page 19)
Fig. 13 · 3.3.3 Reboot System

3.4 Network Configuration

3.4.1 Protocol Control

Selecting on the Network link will allow you to set access methods and set the capability

of future firmware updates. In the Protocol Control section you are presented with the

selections shown below.

HTTP Login Username: Set username for Web interface access to the VC-412. (Note: The password for the Http interface is the same as the console password.) HTTP Security: When disabled you will allow users on your network to view settings and statuses of the VC-412, however modifications are prohibited unless users login through “Become Administrator” option. When enabled, viewing is forbidden unless users provide a correct password to login. BOOTP/DHCP: Obtain IP address from DHCP server.

Telnet Control: Permit or forbid users to login via Telnet.

TFTP Upgrade: Permit or forbid users to upgrade SNMP firmware via TFTP.

Page 20 of the Planet Technology VC-412 user manual — 3.4.2 SNMP Access Table
Page 20 · click to enlarge
Page 20
Planet Technology VC-412 — 3.4.2 SNMP Access Table diagram (page 20)
Fig. 14 · 3.4.2 SNMP Access Table

3.4.2 SNMP Access Table

Under SNMP Access Table and SNMP Trap Receiver Table options, you can set IP

addresses that will be enter into SNMP database relating to the functionality and status of

the VC-412. You can grant or deny accesses to a single PC or an entire subnet by entering

the appropriate IP address. To utilize this feature, you must have a workstation with

SNMP client access and protocols installed. The VC-412 has been tested with HP

OpenView® and Windows NT® SNMP client services, and should be also compatible

with most other SNMP client software. However, we do not recommend users to use

Silvercreek SNMP client, it has been found that it sometimes causes problem to the

firmware.

The SNMP Access Table specifies addresses In-Band or Out-of-Band of your network

that will have the ability to issue SNMP commands to the VC-412. Setting these IP

addresses and passwords will ensure only authorized SNMP clients can issue

commands to the VC-412.

Page 21 of the Planet Technology VC-412 user manual — 3.4.3 SNMP Trap Receiver Table
Page 21 · click to enlarge
Page 21
Planet Technology VC-412 — 3.4.3 SNMP Trap Receiver Table diagram (page 21)
Fig. 15 · 3.4.3 SNMP Trap Receiver Table

3.4.3 SNMP Trap Receiver Table

The SNMP Trap Receiver Table is a set of user-defined addresses that belonged to the

SNMP Trap server. When enabled (entered addresses, 4 receivers maximum) the

VC-412 will send out SNMP information to the trap clients. Currently the VC-412 offers 6

Trap Conditions in addition to port information and counters. The 6 trap conditions are:

1. Unit Up (Power On and Check Status OK)
2. Unit Down (Error or Power Off)
3. Port Link Up (RJ-11 Plugged-in and Link LED is On)
4. Port Link Down (RJ-11 is not plugged and Link LED is Off)
5. Trunk Port Up (RJ-45 is linked and Link/ACT LED is On)
6. Trunk Port Down (RJ-45 is not linked and Link/ACT LED is Off)
Planet Technology VC-412 — 3.4.3 SNMP Trap Receiver Table diagram (page 21)
Fig. 16 · 3.4.3 SNMP Trap Receiver Table
Page 22 of the Planet Technology VC-412 user manual — 3.4.3 SNMP Trap Receiver Table
Page 22 · click to enlarge
Page 22

new settings, failure to do so will result in lost of settings at refresh time.

Page 23 of the Planet Technology VC-412 user manual — 4.2 Management Configuration
Page 23 · click to enlarge
Page 23

4. COMMANDS FOR CONSOLE AND TELNET

Once successfully logged into the VC-412, administrator is ready to issue commands to

the VC-412. This chapter will cover option menus and their structures, giving details to

each option and setting. We will also list the ICD commands index in this chapter. The

ICD commands grant a variety of management controls and monitoring reports.

The following section will discuss the VC-412 Telnet menu structures and their functions.

one minute.

4.1 Main Menu Selections

Planet Technology VC-412 — 4.1 Main Menu Selections diagram (page 23)
Fig. 17 · 4.1 Main Menu Selections

4.2 Management Configuration

By choosing Management Configuration you will reach this sub menu.

Page 24 of the Planet Technology VC-412 user manual — 4.2.1 System Configuration
Page 24 · click to enlarge
Page 24
Planet Technology VC-412 — 4.2.1 System Configuration diagram (page 24)
Fig. 18 · 4.2.1 System Configuration

4.2.1 System Configuration

Choosing System Configuration will allow you to change the basic settings such as IP Address, Subnet, Gateway etc., as well as date and time and login password.

Planet Technology VC-412 — 4.2.1 System Configuration diagram (page 24)
Fig. 19 · 4.2.1 System Configuration

I. Select the number you wished to edit and press “Enter” key. Type in the new

value and press “Enter”. If you do not wish to change any information press

“Enter” key without typing in any information.

Page 25 of the Planet Technology VC-412 user manual — 4.2.1 System Configuration
Page 25 · click to enlarge
Page 25
Planet Technology VC-412 — 4.2.1 System Configuration diagram (page 25)
Fig. 20 · 4.2.1 System Configuration

II. To change password select option 7 and press “Enter” key. Type in the new

password and press Enter.

Planet Technology VC-412 — 4.2.1 System Configuration diagram (page 25)
Fig. 21 · 4.2.1 System Configuration

III. Enter the new password again to confirm.

Page 26 of the Planet Technology VC-412 user manual — 4.2.2 Network Configuration
Page 26 · click to enlarge
Page 26
Planet Technology VC-412 — 4.2.2 Network Configuration diagram (page 26)
Fig. 22 · 4.2.2 Network Configuration

4.2.2 Network Configuration

Choosing the Network Configuration will allow you to set the access methods for

administering the VC-412 as well as some future product enhancements.

Planet Technology VC-412 — 4.2.2 Network Configuration diagram (page 26)
Fig. 23 · 4.2.2 Network Configuration
HTTP Login UsernameSet username for Web interface access on
Page 27 of the Planet Technology VC-412 user manual — 4.2.2 Network Configuration
Page 27 · click to enlarge
Page 27

the VC-412.

to specify username for HTTP access.

HTTP Security ControlWhen enabled, anyone who tries to access

the VC-412 via HTTP is required to enter a password and username

before able to see any settings or information. When disabled, the

VDSL Managerial Switch will allow all users to see and monitor the

settings of the VDSL Managerial Switch, however they will be unable to

make changes, unless they become an administrator by selecting the

“Become Administrator” button in the Web interface.

BootP/DHCP Control: Obtain IP address from DHCP server.

Telnet Control: Permit or forbid access to the VC-412 via the Telnet Console.

TFTP Upgrade ControlPermit or forbid users to upgrade SNNP firmware via

TFTP.

I. To change login username, select option 1 and enter new

username, otherwise press Enter key without entering any

information to cancel operation.

Planet Technology VC-412 — 4.2.2 Network Configuration diagram (page 27)
Fig. 24 · 4.2.2 Network Configuration

II. To Enable or Disable Network properties, select the option

number and press Enter key. Enter the new value and press

Page 28 of the Planet Technology VC-412 user manual — 4.2.3 System MIB Configuration
Page 28 · click to enlarge
Page 28

Enter key, otherwise press Enter key without entering any

information to cancel operation.

Planet Technology VC-412 — 4.2.3 System MIB Configuration diagram (page 28)
Fig. 25 · 4.2.3 System MIB Configuration

4.2.3 System MIB Configuration

Choosing the System MIB Configuration will allow you to set your Management

Information Base fields. This feature allows administrator to enter contact information and

it is useful in situations where there is a problem with the unit or the network. The

customer can refer to this information from the Web interface or console to contact the

vendor or installer. To change this value, select the option number and enter the new

value then press “Enter”, otherwise press “Enter” key without entering any information to

cancel operation.

Page 29 of the Planet Technology VC-412 user manual — 4.3 SNMP Access Table/SNMP Trap Receive Control Table
Page 29 · click to enlarge
Page 29
Planet Technology VC-412 — 4.3 SNMP Access Table/SNMP Trap Receive Control Table diagram (page 29)
Fig. 26 · 4.3 SNMP Access Table/SNMP Trap Receive Control Tabl…

4.3 SNMP Access Table/SNMP Trap Receive Control Table

Choosing option 2 in the Main menu (SNMP Access Table/SNMP Trap Receive Control Table) enables the administrator to set Community and SNMP Access properties.

Planet Technology VC-412 — 4.3 SNMP Access Table/SNMP Trap Receive Control Table diagram (page 29)
Fig. 27 · 4.3 SNMP Access Table/SNMP Trap Receive Control Tabl…
Page 30 of the Planet Technology VC-412 user manual — 4.4.2 Set Each VDSL Port Name of Unit
Page 30 · click to enlarge
Page 30

4.4 VDSL Unit Control

To monitor and issue commands to the VC-412:

Select option 3 - VDSL Unit Control from the Main menu.

Planet Technology VC-412 — 4.4 VDSL Unit Control diagram (page 30)
Fig. 28 · 4.4 VDSL Unit Control

4.4.1 Pass-Through ICD Command to Unit

Option 1 will be discussed in “Using the ICD Command Interface” section. In the section,

you will learn how to access the command line interface (ICD command interface) of the

VC-412, and how to issue commands to the VC-412 via this interface.

4.4.2 Set Each VDSL Port Name of Unit

This option enables users to name or rename ports therefore offering a better port

monitoring organization. When asking for unit number, please input “0” and press Enter.

Page 31 of the Planet Technology VC-412 user manual — 4.4.3 Display All Ports Status of Unit
Page 31 · click to enlarge
Page 31
Planet Technology VC-412 — 4.4.3 Display All Ports Status of Unit diagram (page 31)
Fig. 29 · 4.4.3 Display All Ports Status of Unit

4.4.3 Display All Ports Status of Unit

This option displays the statuses of all twelve VDSL ports. The three counter columns to

the right of the status indicators report the amount of packets have received, sent, and

collided. Using these statistics you will be able to monitor your network status easily and

quickly, allowing you to alleviate network build-up before problems occur.

Planet Technology VC-412 — 4.4.3 Display All Ports Status of Unit diagram (page 31)
Fig. 30 · 4.4.3 Display All Ports Status of Unit
Page 32 of the Planet Technology VC-412 user manual — 4.4.4 Display All Trunks Status of Unit
Page 32 · click to enlarge
Page 32

The E/S/A/Er Column represents the current operating status of the ports.

4.4.4 Display All Trunks Status of Unit

This option will display the statuses of all four trunk ports. The three counter columns to

the right of the status indicators report the amount of packets have received, sent, and

collided. Using these statistics you will be able to monitor your network status easily and

quickly, allowing you to alleviate network build-up before problems occur.

The E/L/A/C Column represents the current operating status of the ports.

Planet Technology VC-412 — 4.4.4 Display All Trunks Status of Unit diagram (page 32)
Fig. 31 · 4.4.4 Display All Trunks Status of Unit
Show 8 more labels / short text on this page
E- Enabled · S- Sync · A- Activity · Er- Error · E- Enabled · L- Link · A- Activity · C- Collision
Page 33 of the Planet Technology VC-412 user manual — 4.6 Reboot System
Page 33 · click to enlarge
Page 33

4.5 Reset To Default

At the Main menu, you have the options to reset the VC-412 to its factory default settings.

The Reset option will reset ALL settings back to factory default; IP Addresses, Gateway

Address, Subnet Address, Auto Refresh Time, and any other commands issued to the

VC-412 will be lost by the reset. Use this option only when there is a malfunction of the

unit that prohibits it from functioning correctly after a reboot or power cycling.

Planet Technology VC-412 — 4.5 Reset To Default diagram (page 33)
Fig. 32 · 4.5 Reset To Default

4.6 Reboot System

The Reboot System command is used to reboot the OS but does not reset or change any

settings of the VC-412 and its firmware. On some occasions you will have to reboot the

firmware. The VC-412 may function improperly after major changes, use the reboot function

to refresh the VC-412 with the new settings.

Page 34 of the Planet Technology VC-412 user manual — 4.7 Logout
Page 34 · click to enlarge
Page 34
Planet Technology VC-412 — 4.7 Logout diagram (page 34)
Fig. 33 · 4.7 Logout

4.7 Logout

After finished issuing commands to the VC-412, it is recommended that you log out of the

interface. Logging out will ultimately end the session and require to re-enter password to

re-login.

Page 35 of the Planet Technology VC-412 user manual — 5.1 Enter ICD command line interface
Page 35 · click to enlarge
Page 35

5. ICD COMMANDS FOR TELNET AND CONSOLE

COMMAND LINE INTERFACE UNLESS YOU HAVE READ THIS SECTION.

This section will discuss accessing the command line interface within the switch, and the

commands available in this mode. It is recommended that you read this section before

proceeding into the command line interface.

5.1 Enter ICD command line interface

From the Main Menu, Select option 3 for VDSL unit control

Planet Technology VC-412 — 5.1 Enter ICD command line interface diagram (page 35)
Fig. 34 · 5.1 Enter ICD command line interface

Now select Option 1 to issue ICD Commands. On “Enter Unit Number:” prompt, press

“0” and “Enter” button to enter ICD command prompt.

Page 36 of the Planet Technology VC-412 user manual — VLAN ON
Page 36 · click to enlarge
Page 36
Planet Technology VC-412 — 5.2 ICD command Index Table diagram (page 36)
Fig. 35 · 5.2 ICD command Index Table

The above line indicates “U00-ICD>”. The unit is now ready to be administered through

ICD commands.

5.2 ICD command Index Table

Please find the following table for available commands.

ICD Console Command & Description Index Table

? Display command list

U Display unit information

S Save data to EEPROM

This command will save:

VDSL and Trunk port settings.

Speed modeauto or preset modes only

RSW Restore factory defaults and reset the switch and ports.

This command will reset all VDSL ports settings

to the following default:

VLAN ON

Command Description · System Command · RS Reboot system

Page 37 of the Planet Technology VC-412 user manual — 5.2 ICD command Index Table
Page 37 · click to enlarge
Page 37

VDSL port Enable Speed Mode = Auto Speed

X To exit ICD command prompt

V Show the current VLAN settings

VO Set VLAN to ON *1

VF Set VLAN to OFF

VG -, ..., Select the to belong to

The available VLAN group number is from 1 to 16. Issue this

VG command will automatically switch the VLAN mode to

USER DEFINED.

Example“ VG 2-1,2,3,B ” will create VLAN group 2 with

member ports:1,2,3 and B.

VG Empty VLAN Ports group

LT - Set VDSL to on local(LT) end

There are six speed levels to select from when

setting VDSL port speed. A, B, C, D is for

VC-101S firmware version R4.5. P is for

firmware version R2 and Q is for firmware

version R4.

A: Downstream 4 Mbps/Upstream 1 Mbps (R4.5) B: Downstream 5 Mbps/Upstream 5 Mbps (R4.5) C: Downstream 11 Mbps/Upstream 11 Mbps (R4.5) D: Downstream 15 Mbps/Upstream 17 Mbps (R4.5) P: Downstream 11 Mbps/Upstream 11 Mbps (R2) Q: Downstream 15 Mbps/Upstream 17 Mbps (R4) Example: “LT 2-B” will configure local port 2’s speed to symmetric 5Mbps

RT - Set VDSL to on remote(RT) end

LR - Set VDSL to preset .

Please then issue S command if you want to save this

settings.

LR - Set VDSL to auto-speed

SR Save data on remote side of VDSL

PC Show all counters for all ports

PC Show all counters for

C Clear all counters for all ports

C Clear all counters for

VLAN Command · VDSL Command · Port Command

Page 38 of the Planet Technology VC-412 user manual — 5.3 Setting VLAN Functionality
Page 38 · click to enlarge
Page 38

P Show the status of all ports. Legend:

RS Err = Reed Solomon Error

* = Don't Care

PE enable

PD Disable

There are three VLAN modesON , OFF and USER DEFINED . When the VLAN mode is

OFF, all VDSL and Ethernet ports can communicate each other. When VLAN

mode is ON, the switch will automatically create the following 13 VLANs. All

VDSL ports cannot communicate each other and can only connect to port A and D.

When VLAN mode is USER DEFINED, you can use VG command to create your

own VLAN settings.

VLAN settings when VLAN is ON:

Group 01 - 1,A,D Group 02 - 2,A,D Group 03 - 3,A,D Group 04 - 4,A,D Group 05 - 5,A,D Group 06 - 6,A,D Group 07 - 7,A,D Group 08 - 8,A,D Group 09 - 9,A,D Group 10 - 10,A,D Group 11 - 11,A,D Group 12 - 12,A,D Group 13 - A,B,C,D

5.3 Setting VLAN Functionality

The VLAN function offers security and flexibility of controlling each port’s access to one

another. This feature is useful in MDU and hotel situations where you would not want

each computer to be able to “see” all other computers connected to the VC-412. However,

in some situation you may need to have a few ports with the capability of communicating

with one another. Such situations may arise for sharing files, collaboration software,

faster multi-player gaming, etc.

Activating the VLAN function allows each port to be individualized, and

Show 4 more labels / short text on this page
AUT = Auto · PRE = Preset · MAN = Manual · P/A = Preset/Actual
Page 39 of the Planet Technology VC-412 user manual — 5.3 Setting VLAN Functionality
Page 39 · click to enlarge
Page 39

non-communicative to the other ports on the VC-412 in regards to local traffic.

Deactivating VLAN allows the switch to act as a normal Ethernet VC-412, by passing

along multicast and broadcast traffic to each port. Disabling this feature would be useful

when installing the VC-412 in office settings and for file/print sharing.

Within the ICD command interface or web interface, you can turn the VLAN function on or

off. In ICD simply type “VO” to activate the VLAN function, and “VF” to deactivate the

VLAN function.

Ethernet ports (port-A and port-D). Hence, Ethernet port-B and port-C will not grant any

bandwidth to VDSL ports. Therefore, trunking can be only done via port-A and port-D.

Turning VLAN off will enable all four Ethernet ports accessible to all VDSL ports, however,

it sometimes causes the switch to halt since the Ethernet port-B and port-C are designed

for different purposes.

VC-412 also allows VLAN Grouping, which enables user to define ports to communicate

with each other, while remaining isolated from the other ports (outside the defined range)

traffic. The VC-412 supports up to 16 different groupings, and can only be set within the

ICD Command Interface. The ICD Command for VLAN Grouping is VG.

The command line format is as follow:

Syntax Description [VG] Command string.

[Group] Group number, from 01 to 16.

[port1,…,portN] List of ports to be included in the group separated by commas, the VDSL ports are numbered with 01 to 12 and Ethernet ports are ordered from A to D.

for the same group will overwrite the previously saved list for that group.

Examples:

To group VDSL port-1, port-2, and Ethernet port-A together you will need to issue the

following commands:

[VG] [Group]-[port1,…,portN] · [-] Command string

Page 40 of the Planet Technology VC-412 user manual — 5.4 VDSL Command
Page 40 · click to enlarge
Page 40

VG 1-1,2,A

Add port-4, port-8 and port-D to group 1 from previous example

VG 1-1,2,4,8,A,D

Delete port-2 and port-8, port-A of group 1 from previous example

VG 1-1,4,D

VG 1-

Add port-1, port-3, port-6, port-10, port-B, port-C, port-D to group 5

VG 5-1,3,6,10,B,C,D

You can verify the VLAN groups through the “V” command.

5.4 VDSL Command

For VDSL local and remote connections to establish, local switch and remote modem

must adjust to a corresponding rate. However if the distance between VC-412 and the

remote VDSL modem is too far then connection may not establish with high stream rates.

Therefore the VC-412 VDSL Managerial Switch and the VDSL remote modem are factory

set to the lowest stream rate; 4 Mbps downstream and 1 Mbps upstream. Once

connection between the VC-412 and the remote modem is established the switch will try

to adjust the stream rate to the next higher speed mode. If the next new stream rate failed

then it will go back to speed level-A (LWD mode) and progressively adjust to the last

highest effective rate. It will take approximately 10 seconds for the VC-412 to recalibrate

to LWD mode. This is called auto-speed.

In some situations higher stream rate is reachable but line quality might be poor due to

environmental factors or/and bad line conditions. In such circumstances, administrators

will want to define the maximum steam rate to a more stable rate. For example, if you

want to define the maximum speed on port-5 to speed level-B (5 Mbps symmetric) then

you can issue LR 5-B in the ICD command interface. Doing so will preset port-5

maximum speed to level-B therefore it will establish connection from speed level-A and if

succeeded, it will progress to level-B and stays at that point if it is reachable.

You can also manually set the port speed for testing purposes. To experiment, you must

first manually set the remote modem to a desired speed and then set the speed on the

Empty group 1

Page 41 of the Planet Technology VC-412 user manual — 5.5 Port Command
Page 41 · click to enlarge
Page 41

connected port of the VC-412 to the same speed. The reason you need to set the speed

on the remote modem first is when you adjusts the speed on the remote modem,

connection with end since speeds on both sides will be different. After setting the VC-412

port to the same speed as the remote modem, connection will re-establish if it is within

the distance limitation. For example if you want to test the quality of transmission with the

stream rate speed at speed level-B (5 Mbps symmetric). You will enter the following

commands in the ICD command interface.

RT 10-B Connection will end

LT 10-B Connection will re-establish if within the range. If connection does not establish with new speed level, reset the switch and wait

approximately 47 seconds for the switch and the remote modem to recalibrate.

5.5 Port Command

The “P” command displays all the VDSL ports status including its speed and speed mode.

AUT represents Auto-speed mode, PRE represents preset speed and MAN represents

manual set speed. At the speed column you will see a representation of preset speed and

the current speed of each port. The numerator is preset speed (“*” means not applicable)

and the denominator is current speed. Please refer to the ICD Command Index table for

reference.

Page 42 of the Planet Technology VC-412 user manual — 5.5 Port Command
Page 42 · click to enlarge
Page 42
Planet Technology VC-412 — 5.5 Port Command diagram (page 42)
Fig. 36 · 5.5 Port Command

The “PC” command displays all ports Transmit, Receive and Collision statuses.

Planet Technology VC-412 — 5.5 Port Command diagram (page 42)
Fig. 37 · 5.5 Port Command
Page 43 of the Planet Technology VC-412 user manual — APPENDIX A – VC-412 FACTORY DEFAULT
Page 43 · click to enlarge
Page 43

APPENDIX A – VC-412 FACTORY DEFAULT

Virtual LAN – On

Ethernet Speed – 100 Full/Half Duplex

VDSL Port Line Rate –

Downstream at 4 Mbps

Upstream at 1 Mbps

IP Address – 192.168.1.1

Page 44 of the Planet Technology VC-412 user manual — LT 2-P
Page 44 · click to enlarge
Page 44

APPENDIX B – UPDATE VC-101S FIRMWARE TO

R4.5 REMOTELY THROUGH VC-412

The purpose of this appendix is to upgrade older versions of VC-101 (R2 or R4) into the

newest version (R4.5) remotely through VC-412. The new version will contain

auto-speed function which can seek the maximum transmission speed automatically.

The default speed of version R4.5 VC-412 Mbps downstream/1 Mbps upstream but the

default speed of version R2 is 11 Mbps symmetric and default speed of version R4 is 15

Mbps downsteam/17 Mbps upstream. Therefore you will need to adjust both VC-412 and

VC-101S to a complementary speed in order to establish link. You can perform these

procedures remotely via VC-412 console or telnet.

1. Login to the VC-412 via console or telnet.
2. Access to the ICD Command interface.
Planet Technology VC-412 — APPENDIX B – UPDATE VC-101S FIRMWARE TO diagram (page 44)
Fig. 38
3. Adjust the speed on VC-412 to the remote modem’s speed with the following

command:

LT -

For example if port-2 is connected to a version R4 VC-101S the command would be:

LT 2-Q

If it is connected to a version R2 VC-101S then use the command would be:

LT 2-P

Page 45 of the Planet Technology VC-412 user manual — P R2 (12.5/12.5)
Page 45 · click to enlarge
Page 45

can not be saved. Thus, you have to continue the following command to update

the VC-101S firmware.

Refer to the table below for speed versions

P R2 (12.5/12.5)

Q R4 (18/16)

A LWD (4/1)

4. Now set the remote modem’s speed to A which is the LWD mode.
Command DescriptionRT <port>-<LWD speed mode>
CommandRT 2-A

will end once the remote modem’s speed differs from the local switch.

5. Now set the speed of VC-412 back to LWD mode.
Command DescriptionLT<port>-<LWD speed mode>
CommandLT 2-A
6. Save remote modem’s setting so it will not be lost upon power cycling.
Command DescriptionSR <port>
CommandSR 2
7. Adjust the VC-412 back to auto-speed mode.
Command DescriptionLR <port>-
CommandLR 2-

The figure below illustrates the commands to upgrade a version R4 VC-101S remotely

via VC-412 ICD command.

Speed VC-101S Version

Page 46 of the Planet Technology VC-412 user manual — APPENDIX B – UPDATE VC-101S FIRMWARE TO R4.5 REMOTELY THROUGH VC-412
Page 46 · click to enlarge
Page 46
Planet Technology VC-412 — APPENDIX B – UPDATE VC-101S FIRMWARE TO R4.5 REMOTELY THROUGH VC-412 diagram (page 46)
Fig. 39

For more detailed ICD command description please refer to the Chapter 5.

Ask about the Planet Technology VC-412

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Planet Technology VC-412

Be the first to ask — other owners or our team will answer.

Original document

Planet Technology VC-412 manual PDF

46 pages·1.1 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…