RS-232/RS-422/RS-485 over 100Base-FX / 10/100Base-TX Media Converter

Copyright © PLANET Technology Corp. 2008.
Contents subject to which revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and
makes no warranty and representation, either implied or expressed, with respect to the quality, performance,
merchantability, or fitness for a particular purpose.
PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability for any
inaccuracies or omissions that may have occurred.
Information in this User's Manual is subject to change without notice and does not represent a commitment on the part of
PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User's Manual. PLANET
makes no commitment to update or keep current the information in this User's Manual, and reserves the right to make
improvements to this User's Manual and/or to the products described in this User's Manual, at any time without notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and
suggestions.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at whose own expense.
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user
may be required to take adequate measures.
To avoid the potential effects on the environment and human health as a result of the presence of
hazardous substances in electrical and electronic equipment, end users of electrical and electronic
equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of
WEEE as unsorted municipal waste and have to collect such WEEE separately.
PLANET RS-232/RS-422/RS-485 over 10/100Base-TX/100Base-FX Media Converter User's Manual
REVISION: 1.1 (APRIL.2008)
Part No.: 2080-AA3600-000



Thank you for purchasing PLANET Serial over Fast Ethernet Media Converter – ICS-10x series. Terms of “Serial Media
Converter” means the products mentioned titled in the cover page of this User’s manual
Open the box of the Serial Media Converter and carefully unpack it. The box should contain the following items:
Check the contents of your package for following parts:
Serial Media Converter x1
CD-ROM user's manual x1
Quick installation guide x1
External 5VDC / 2.5A power adapter x 1
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the
original packing material, and use them against to repack the product in case there is a need to return it to us for repair.
This Media Converter User Manual is structured as follows:
Section 2, Installation
It explains the functions of ICS-10x and how to physically install the ICS-10x.
Section 3, Management
The chapter explains how to manage the converter by Web interface.
Section 4, Web Configuration
It contains information about the Smart function of ICS-10x.
Section 5, Software VCOM Utility
It explains the software VCOM how to use with the operation Virtual COM.
It contains cable information of ICS-10x.
Appendices

The Web-Smart ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485
communication interface over Fast Ethernet networking. There are RJ-45/SC connectors and
single-mode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily,
efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET
Media Converter Chassis (MC-700, MC-1000 and MC-1500). It’s time saving expense for user and SI, no need to
replace the existing Serial equipment and software system.
It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of
distance are flexibly provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable
and efficient network solutions based on the distance and budgets of installation.
The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a
TCP/IP networking immediately. Each Web-Smart converter is able to manage through the Web Interface. The powerful
Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc.
Management function helps reduce the amount of valuable time that a network administrator spends detecting and
locating network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection options
for large networking environment are available as well.
Access Control System – traditional installation
Most of the enterprise and government use access control plate and Mifare or RFID to authorize the entrance identity.
With traditional deploy, access control machine use RS-232 or RS-485 serial interface and cables connect to login server.
With connection to ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extend over
longer distances via fiber optical interface. The distance can be up to 20km in a local range. Or the ICS-10x can be linked
to a xDSL router to get the internet access capability; the access control can be set and monitored over the internet.

Figure 1-1 Serial Converter for Access Control System application

To monitor, configure and manage the Robot conveyer including other machines in a manufacturing, PLC (Programmable
Logical Control) is required. The PLC is used to drive above the manufacturing machines process. The ICS-10x can be set
to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast
Ethernet intranet to control the PLC, the administrator and workstation. There is no need to be always sets by the side of
the I/O machine.

Figure 1-2 Serial Converter for factory PLC application
RTU Data Collect – UDP Mode
Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, signal and power utilization. ICS-10x
can be used to set-up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server
automatically.

Figure 1-3 Serial Converter for factory RTU application
Process Control

Surveillance motion control – Pair Connection Mode
Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232/RS-485 interfaces distance from
surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.

Figure 1-4 Serial Converter for distance extend application
One RS-232/422/485 port to one 10/100Base-TX or 100Base-FX Media Converter
Cost effective solution for RS-232 to Ethernet application
Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation
Asynchronous serial data rates up to 921600b/s
Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX standard
Supports auto MDI/MDI-X function on RJ-45 Port
Choice of fiber-connector from SC, multi-mode / single-mode fiber
Standard TCP/IP interface and versatile operation modes
Software Protocol Support ARP, ICMP,TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client
Built-in IP-Base Web interface for remote management
Serial Operation mode selected via Web management
Pair Connection mode for connecting two serial devices over a network
PLANET Smart Discovery utility automatically finds xxx devices on the network
Firmware upgrade via HTTP protocol
Compact size for easy Installation:
¾ Standalone - Wall mountable or DIN-Rail mounting (Optional accessory)

¾ Co-work with PLANET MC family Media Chassis ( MC-700/1000R/1500)
LED indicators for easy network diagnose
Reset Button at the front panel for reset to factory default




This section describes the hardware features and installation of the ICS-10X’s components on the desktop or shelf. For
easier management and control of the ICS-10x, familiarize yourself with its display indicators, and ports. Front panel
illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Serial Media
Converter, please read this chapter completely.
Figure 2-1 to Figure 2-4 show layout and front panel of ICS-10X.
ICS-100 – RS-232 / RS-422 / RS-485 over 10/100Base-TX

Figure 2-1 ICS-100 panel layout


Figure 2-2 PLANET ICS-100 Front Panel
ICS-102 / ICS-102S15 – RS-232 / RS-422 / RS-485 over 10/100Base-FX

Figure 2-3 ICS-102 / ICS-102S15 panel layout

Figure 2-4 PLANET ICS-102 Front Panel


PWR Green Lights to indicate that the Converter is powered on.
Lights To indicate that the Fast Ethernet Port is successfully connecting to the network at 10Mbps or 100Mbps TP or Fiber Green
Blinks To indicate the Fast Ethernet Port is receiving or sending data
Lights To indicate that the UART Port is connected successfully Serial Green
Blinks To indicate the UART Port is receiving or sending data
DB9 Pin Define for RS-232 / RS-422 / RS-485

2.1.4 ICS-10X Rear Panel
The rear panel of the converter indicates one DC jack, which accepts input power with 5V DC 2.5A.

Figure 2-5 Rear Panel of ICS-10x
Power Notice:

To press and release the RESET button. The ICS-10X will back to the factory default mode. Be sure that
you backup the current configuration of ICS-10X; else the entire configuration will be erased when
pressing the “RESET” button.
This section describes how to install your ICS-10X Web Smart Media Converter and make connections to the converter.
Please read the following topics and perform the procedures in the order being presented. The hardware installation of
PLANET ICS-10X Web Smart Media Converter do not need software configuration. To install your ICS-10X on a desktop
or shelf, simply complete the following steps.
To install an ICS-10X stand-alone, on a desktop or shelf, simply complete the following steps:

Figure 2-6 ICS-100 stand alone installation


Figure 2-7 ICS-102 / ICS-102S15 stand alone installation
Please refers to APPENDIX-A for detailed wiring information of the ICS-10X.
To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the
converter.
To install the Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described below.

Figure 2-8 Insert a Media Converter into an available slot

shown in Figure 2-2.
and supply power to your converter.
You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.

Figure 2-9 Mounting the Chassis in a Rack

This chapter describes how to manage the ICS-10X. Topics include:
- Assigning an IP address to the ICS-10X
- Logging on to the ICS-10X
This chapter gives an overview of converter management. The ICS-10X provides a simply WEB browser interface.
Using this interface, you can perform various converter configuration and management activities, including:
Serial Port Configuration
Please refer to the following Chapter 4 for more details.
For ICS-100: Use standard network (UTP) cables with RJ45 connectors.
For ICS-102 / ICS-102S15: Use Multi-mode or Single Mode fiber patch cord with SC connectors.
other platform compatible with TCP/IP protocols.
It is recommended to use Internet Explore 6.0 or above to access Serial Media Converter.

The way to manage the ICS-10X:
- Web Management via a network or dial-up connection
The PLANET Web-Smart Media Converter provides a built-in browser interface. You can manage the ICS-10X remotely
by having a remote host with web browser, such as Microsoft Internet Explorer, Netscape Navigator or Mozilla Firefox.
Using this management method:
The ICS-10X must have an Internet Protocol (IP) address accessible for the remote host.

Figure 3-1 Web Management over Ethernet
Before you start configure the ICS-10X, please note the ICS-10X is configured through an Ethernet connection, make sure
the manager PC must be set on same the IP subnet address.
For example, the default IP address of the ICS-10X is 192.168.0.100, then the manager PC should be set at 192.168.0.x
(where x is a number between 2 and 254), and the default subnet mask is 255.255.255.0.
address) to access the Web interface.
password is "admin"). Press Login to enter the main screen of ICS-10X. The login screen in Figure 3-1 appears.


Figure 3-2 Login screen

The ICS-10X Web Smart Media Converter provide Web interface for Converter smart function configuration and make the
Converter operate more effectively - They can be configured through the Web Browser. A network administrator can
manage and monitor the ICS-10x from the local LAN. This section indicates how to configure the Media Converter to
enable its smart function.
After a successful login, the main screen appears, the main screen displays the converter Welcome page. The screen in
Figure 4-1 appears.

Figure 4-1 Web Main screen
As listed at the left of the main screen, the configurable smart functions are shown as below:
System – Check the hardware, software version and System MAC address and IP address of the converter. And the password changed firmware upgrade / Factory default / system reboot.
Network Configuration- Setup the IP address of the converter.
Operation Mode – Setup the serial port mode: “TCP server”, “TCP client”, “UDP client”, “Virtual COM”, “Telnet Server”, “Pair Connection – Remote (Master)” and “Pair Connection – Remote (Slave)”.
Serial Port Configuration- Setup the serial port value

The System Information page provides information for the current device. System Info page helps a network manager to
identify the versions and IP Address etc. The screen in Figure 4-2 appears.

Figure 4-2 System Information screen
The page includes the following fields:
Show the current serial port operation mode.

This function provides administrator to secure Web login. The screen in Figure 4-3 appears.

Figure 4-3 Password Setting screen
The page includes the following configurable data:
Login Name Displays the user name.
New Password Specifies the new password. The password is not displayed. As it entered an “y” corresponding to each character is displayed in the field.
(The maximum length is 15 characters)
Confirm Password This confirms the new password. The password entered into this field must be exactly the same as the password entered in the Password field.
After change the default password, if you forget the password. Please press and release the “Reset” button in the front panel of ICS-10X, the current setting will be lost and the ICS-10X will restore to the default mode.

The Firmware Upgrade page contains fields for downloading system image files from the Local File browser to the
device. The screen in Figure 4-4 appears.

Figure 4-4 Firmware Upgrade screen
To open Firmware Upgrade screen perform the folling:

Figure 4-5 Firmware Upgrade screen


Figure 4-6 Firmware Upgrade screen
Click the “Browse” button of the main page, the system would pop up the file selection menu to choose firmware.

Figure 4-7 Windows file selection menu popup
Do not power off the converter until the update progress is complete.
Do not quit the Firmware Upgrade page without press the “Upgrade” button - after the image is loaded. Or the system won’t apply the new firmware. Users have to repeat the firmware upgrade processes again.

The Factory Default can reset the ICS-10x back to the factory default mode. Be aware that the entire configuration will be
reset, and the IP address of the ICS-10x will be set to “192.168.0.100”. The screen in Figure 4-8 appears.

Figure 4-8 Factory Default progress screen
The System Reboot can restart the ICS-10x. The screen in Figure 4-9 appears.

Figure 4-9 System Reboot progress screen

This function allows setting the value for network configuration. The value is DHCP client, IP address, Subnet Mask,
Gateway, DNS and system name. Press the “Apply” button to set the value. The screen in Figure 4-10 appears.

Figure 4-10 Network Configuration screen
The page includes the following configurable data:
When DHCP Client is set to “Enable”, the ICS-10x will send a DHCP request to the
DHCP server in the network. Once the DHCP Server get the request, it will assign a
dynamic IP address, netmask and gateway to the ICS-10x.
The factory default setting is “Disable”
The factory default value is 192.168.0.100
The factory default value is 255.255.255.0
The factory default value is 192.168.0.254
addresses. A domain name is an alphanumeric name, such as planet.com, that it is
usually easier to remember. Assign the DNS server IP address.

When DHCP Client is set to Enable, the IP Address, Subnet Mask, Gateway and DNS fields are not
allow to be changed.
If the Media Converter is set to DHCP Client enable, you can use PLANET Smart Discovery or
PLANET VCOM Utility to search the Media Converter which with DHCP assigned IP address.
The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a TCP/IP
networking immediately. The ICS-10x allow traditional Computer/Client COM ports access to a serial equipment
anywhere on the Ethernet LAN network.
This Operation Mode configure page allows setup Serial interface operation mode as below:
Pair connection (local)
Pair connection (Master)

Figure 4-11 Operation Mode Configuration screen
Select the operation mode for the application and press the “Apply” button to take affect.
When the ICS-10x be configured to TCP Server mode, it allows Serial device that connected to serial port of ICS-10x to establish TCP communication over Intranet or Internet network between:
Remote Host (Computer) with Serial applications using TCP/IP network socket programs

Other ICS-10x with TCP Client mode
It opens the TCP port of ICS-10x to wait for serial application to establish a TCP connection. After the connection is
established, data can be transmitted in both directions.
The parameter defines the maintenance status for listen for the TCP connection.

Figure 4-12 TCP Server mode
The screen in Figure 4-13 appears. When the changed operation mode, the user should be changed the Serial Port
Configuration.

Figure 4-13 TCP Server Configuration screen
The page includes the following fields:
Choose different mode:
Pair connection (local)
Pair connection (Master)
The default mode is “TCP Server”.

HyperTerminal is a program that you can use to connect to other computers, Telnet sites, online services, and host
computers, using either your modem, a null modem cable, a Console cable or Ethernet connection.
The users want to use the TCP Server mode to connect to a Ethernet Switch via Hyper Terminal, Winsock mode
“23”.




Figure 4-16 Example Hyper Terminal screen





Host address The address or name of the connection you want to create. This can be in standard Internet
dotted notation (for example, w.x.y.z) or can be the site's user-friendly name.
port The number of the port that you want the connection to use. Port 23 is the default.

Figure 4-20 TCP/IP Winsock connection screen
Value Description

When the ICS-10x be configured to TCP Client mode, it allows Serial device that connected to serial port of ICS-10x to
establish TCP communication actively over Intranet or Internet network between:
Remote Host (Computer) with Serial applications using TCP/IP network socket programs
Other ICS-10x with TCP Server mode
After the data has been transferred, the ICS-10x can disconnect automatically from the Remote Host depends on the TCP
Inactive timeout settings. The parameter defines the maintenance status for listen for the TCP connection.
Figure 4-21 TCP Client Mode
The screen in Figure 4-22 appears. When the changed operation mode, the user should be changed the Serial Port
Configuration.

Figure 4-22 TCP Client Configuration screen
The page includes the following fields:
Allow the ICS-10X to connect actively to the remote host whose IP address is set by this parameter.
The remote host port number that ICS-10X uses to listen to connections and that other device must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the default is set to “1024”.

When the ICS-10x be configured to UDP Client mode, it allows Serial device that connected to serial port of ICS-10x to
quickly transmit data to multiple Remote Hosts over Intranet or Internet network by unicast or multicast. It also makes the Serial device to receive data from more than one Remote Hosts.
The parameter defines the maintenance status for listen for the UDP connection. In UDP Client mode, you need to define the remote IP Address and Local listen port number.

Figure 4-23 UDP Client Mode
The screen in Figure 4-24 appears. When the changed operation mode, the user should be changed the Serial Port
Configuration.

Figure 4-24 UDP Client Configuration screen

The page includes the following fields:
When the ICS-10x be configured to Virtual COM mode, it allows Serial device that connected to serial port of ICS-10x to establish TCP communication over Intranet or Internet network between Remote Host (Computer). The Virtual COM Port
driver has to be installed at the Remote Host. Users can send data by Virtual COM port, and Virtual COM port will transfer
data to Ethernet by windows socket. The Virtual COM driver maps IP Address / Port of ICS-10x to a local COM port on the
Remote Host (Computer). Once the Virtual COM connection is established, the applications work as the serial device is
direct connected to the Remote Host’s real COM port. After the connection is established, data can be transmitted in both
directions.
With connect to ICS-10x Serial over Fast Ethernet Converter, the serial devices are not limited to physical connection to
the PC/Remote Host COM port and able to be extension over longer distance. The parameter defines the maintenance
status for the Virtual COM.

Figure 4-25 Virtual COM Mode
When the changed operation mode, the user should be changed the Serial Port Configuration. The screen in Figure 4-14
appears.

Figure 4-26 Virtual COM Configuration screen

The page includes the following fields:
must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the
default is set to “1024”.
there is no activity on the serial line before the set time expires. To disable the
inactive timeout enter “0”.

Figure 4-27 Example Virtual COM Mode
The user want to use the virtual COM like to use the serial cable connect the switch.
to “23”.







choose COM9 (as created in Step-4)






TELNET (TELecommunication NETwork) is a network protocol used on the Internet or local area network (LAN)
connections. The Telnet protocol type is the correct setting for most servers and serial devices, such as Managed Ethernet
switches or Gateways. In most of the case, the telnet use TCP port 23 as communication port.
The parameter defines the maintenance status for Telnet server.

Figure 4-37 Com port screen
When the changed operation mode, the user should be changed the Serial Port Configuration. The screen in Figure 4-38
appears.


Figure 4-38 Telnet Server Configuration screen
The page includes the following fields:
The ICS-10X’s “telnet server mode”--if the user used the MS-DOS telnet command it will
show double character. So the user can use other Telnet software like: “putty” or “NetTerm”.

Figure 4-39 Example Telnet Server


Figure 4-40 Example Windows Excuse - Telnet
In this case we type “open 192.168.0.100” and press enter.

Figure 4-41 Example Windows Excuse - Telnet
switch.


Figure 4-42 Example Windows Excuse - Telnet

Figure 4-43 Example Windows Excuse - Telnet
PuTTY is a free implementation of Telnet and SSH for Win32 and Unix platforms, along with an xterm terminal emulator.
In this case we use Putty to telnet to the ICS-10x-Telnet Server mode for remote console login.


Figure 4-44 Putty Configuration screen

Figure 4-45 Putty telnet screen

The parameter defines the maintenance status for listen for the pair connection. To make a long distance communication between two serial equipment, configure two ICS-10x with Pair Connection mode and setup one as a Master (Local side)
and the other as a Slave (Remote side).
Pair Connection – Local (Master) – the ICS-10x is locate close to the Host Computer or control device and
connect to it via serial interface.
Pair Connection – Remote (Slave) – the ICS-10x is locate close to the remote serial equipment and connect to it via serial interface..

Figure 4-46 Pair Connection mode
In effect, this converter will be acting as a TCP server. The screen in Figure 4-46 appears. When the changed operation
mode, the user should be changed the Serial Port Configuration.

Figure 4-47 Pair Connection – Local (Master) Configuration screen

The parameter defines the maintenance status for listen for the pair connection. In effect, this converter will be acting as a TCP client. The screen in Figure 4-48 appears.
When the changed operation mode, the user should be changed the Serial Port Configuration.

Figure 4-48 Pair Connection – Remote (Slave) Configuration screen
While using Pair Connection mode for two RS-232 services distance extend, the DB9/RS-232 cables
are very importance in this application. There are much kind of RS-232 cables, such as straight cable
(standard) and Null-Modem cable. Please make sure the DB9/RS-232 cables match the below
constriction:
Serial Device to ICS-10x/Remote (Slave) – Use the original RS-232 serial cable attached in the
serial device package.
Host / Client to ICS-10x/Local (Master) – It has to use the Null-Modem cable!
Users can use the Null-Modem cable directly connect to the ICS-10x (Master), or use the Null-Modem
DB9 connector, as the picture shows:



Once the Pair Connection mode of two ICS-10x be correctly configured but still fail link, check the RS-232 cables!

One be configured as Pair Connection – Local (Master) The other one be configured as Pair Connection – Remote (Slave)
Via the RS-485 interface, the external scanners, speed dome cameras and PTZ receivers can be controlled by the
keyboard which provides upward, downward, leftward, rightward, clockwise and counterclockwise with the joystick. In this
case, we use two ICS-10x to extend the distance between an IP surveillance PT Camera and a Control keyboard. Both of
the two equipments are implemented with RS-485 interface.
The two of the ICS-10x master and slave with below settings:
Connect to Control Keyboard
IP Address / Subnet Mask 192.168.0.100 / 255.255.255.0
Serial Mode: RS-485 Baudrare: 9600 Character Bits: 8 Parity Type : none Stop Bit : 1 Hardware Flow Control: none
Connect to Speed Dome Camera, PTZ or Scanner
IP Address / Subnet Mask 192.168.0.101 / 255.255.255.0
Mode: Pair Connection – Remote Remote Host IP Address : 192.168.0.100 Remote Host Port Number : 1024
Serial Mode: RS-485 Baudrare: 9600 Character Bits: 8 Parity Type : none Stop Bit : 1 Hardware Flow Control: none
Topology:

Figure 4-49 Two ICS-10x configured with Pair-Connection

“ Pair Connection-Local (master)”
Figure 4-50 Pair Connection – Local, operation mode configuration
Figure 4-51 Pair Connection – Local, serial port configuration
“ Pair Connection-Local (master)”


Figure 4-52 Pair Connection –Remote, operation mode configuration
Figure 4-51 Pair Connection – Local, serial port configuration

The page shows the converter’s serial Port configuration. The screen in Figure 4-52 appears.

Figure 4-52 Converter Status page screen
The page includes the following fields:
The default is “8”.
The default value is “none”.

contained in the serial buffer is paced in an Ethernet packet and sent out the Ethernet port.
Silent Time: For the defined period of time passed, the serial port stops data transmission and close the connection to remote host.
Drop Character: If the incoming data contain character 1 or character 2, the packet will be dropped
The default value is “Disable”
Press this function; the web interface will go back to login screen. The screens in Figure 4-53 and Figure 4-54 appear.

Figure 4-53 Logout dialogues screen

Figure 4-54 Login screen

The ICS-10X Web Smart Media Converter provides software for Converter smart function configuration when the
Converter operation mode on “Virtual COM”. - They can be configured through the Console. Two function groups are
provide to easy used, can search device and create virtual COM to view as the console port.
This program can search ICS-10x Series devices, it will show information of the device. And user can use VCOM function
creates virtual com port for user using. Users can send data by virtual com port, and virtual com port will transfer data to
Ethernet by windows socket. While VCOM got data from Ethernet, it will transfer data to virtual com port by virtual com
component.
The VCOM is an integrated software suite that bundles Device Server Administrator and IP Serial Library, and provides
something you need to monitor your ICS-10X from a remote location.
installation.

Figure 5-1 VCOM installation screen

Figure 5-2 VCOM installation screen


Figure 5-3 VCOM installation screen

Figure 5-4 VCOM program path
show the virtual COM information.

Click the Search Device button to find the ICS-10X. It will show the ICS-10X device name, project name, MAC address, IP
address, Sub Mask, Gateway and the connect port number.
name in the tree report. While user click the device name, it will show device information in the list report.

Figure 5-5 VCOM Device Search
This function should be set the ICS-10X’s operation mode to “Virtual COM” on the Web.
Choose to create port like below:

Figure 5-6 VCOM Configuration
Figure 5-7 Hyper Terminal Configuration

Figure 5-8 VCOM Configuration
added to the device list.

Figure 5-9 Windows Device Server - Virtual COM Port
When the Virtual COM create com port, the Device Manager will add “Virtual Serial Port”.
And delete the Port on the VCOM, the device will disappear.

A.1 PLANET Smart Discovery Utility
For easily list the ICS-10X in your Ethernet environment, the Planet Smart Discovery Utility from user’s manual CD-ROM
is an ideal solution.
The following install instructions guiding you for run the Planet Smart Discovery Utility.

Figure A-1 Planet Smart Discovery Utility Screen
If there are two LAN cards or above in the same administrator PC, choose different LAN card by
use the “Select Adapter” tool.

Figure A-2 Planet Smart Discovery Utility Screen

Device IP Subnet address, also can assign new password, IP Subnet address and description for the devices.
the 3 buttons above are shown as below:
Update Device: use current setting on one single device.
Update Multi: use current setting on choose multi-devices.
Update All: use current setting on whole devices in the list.
The same functions mentioned above also can be finding in “Option” tools bar.
Switch under different IP subnet address.
¾ DB9 Pin Define for RS-232 / RS-422 / RS-485

A.3 Device‘s RJ-45 Pin Assignments

Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly
forbidden, is beyond the scope of this standard.


There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection:

SIDE 1 1 2 3 4 5 6 7 8
SIDE 1 1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 SIDE 2
Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network.

The wiring details are as below:
Standard Fiber Type Cable Specification
Multi-mode 50/125μm or 62.5/125μm
Multi-mode 50/125μm or 62.5/125μm 100Base-FX
The power jack of ICS-10X is with 2.5mm in the central post and required +5VDC power input. It will conform to the
bundled AC-DC adapter and Planet’s Media Chassis. Should you have the problem to make the power connection, please
contact your local sales representative.
Please keep the AC-DC adapter as spare parts when your ICS-10X is installed to a Media Chassis.
2.5mm
DC Receptacle 2.5mm
+5V for each slot
DC receptacle is 2.5mm wide that conforms to and matches the Media Converter 2.5mm DC jack's central post. Do not install any improper unit, model of the Media Converter
100Base-FX · (1300nm) · (1310nm) Single-mode 9/125μm


EC Declaration of Conformity For the following equipment: *Type of Product : RS-232 / RS-422 / RS-485 over 10/100Base-TX Media Converter (1 DB9, 1 RJ-45) *Model Number : ICS-100 * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien Taipei, Taiwan , R. O.C. is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (89/336/EEC). For the evaluation regarding the EMC, the following standards were applied:
Emission EN 55022 (1994 + A1:1995 + A2:1997 Class A) Harmonic EN 61000-3-2 (2000) Flicker EN 61000-3-3 (1995 + A1:2001) Immunity EN 55024 (1998) ESD IEC 61000-4-2 (1995 + A1:1998 + A2:2000) RS IEC 61000-4-3 (1995 + A1:1998 + A2:2000) EFT/ Burst IEC 61000-4-4 (1995 + A1:2000) Surge IEC 61000-4-5 (1995 + A1:2000) CS IEC 61000-4-6 (1996 + A1:2000) Magnetic Field IEC 61000-4-8 (1993 + A1:2000) Voltage Disp IEC 61000-4-11 (1994 + A1:2000)
⌧ Manufacturer Authorized representative established within the EU
Company Name: Planet Technology Corp.
Person responsible for making this declaration
Name, Surname Kent Kang
Taiwan 18, March., 2008 Place Date Legal Signature
e-mail: sales@planet.com.tw http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528

EC Declaration of Conformity For the following equipment: *Type of Product : RS-232 / RS-422 / RS-485 over 100Base-FX Media Converter (1 DB9, 1 Fiber SC connector) *Model Number : ICS-102 / ICS-102S15 / ICS-105A * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien Taipei, Taiwan , R. O.C. is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (89/336/EEC). For the evaluation regarding the EMC, the following standards were applied:
Emission EN 55022 (1994 + A1:1995 + A2:1997 Class A) Harmonic EN 61000-3-2 (2000) Flicker EN 61000-3-3 (1995 + A1:2001) Immunity EN 55024 (1998) ESD IEC 61000-4-2 (1995 + A1:1998 + A2:2000) RS IEC 61000-4-3 (1995 + A1:1998 + A2:2000) EFT/ Burst IEC 61000-4-4 (1995 + A1:2000) Surge IEC 61000-4-5 (1995 + A1:2000) CS IEC 61000-4-6 (1996 + A1:2000) Magnetic Field IEC 61000-4-8 (1993 + A1:2000) Voltage Disp IEC 61000-4-11 (1994 + A1:2000)
⌧ Manufacturer Authorized representative established within the EU
Company Name: Planet Technology Corp.
Person responsible for making this declaration
Name, Surname Kent Kang
Taiwan 24, March., 2008 Place Date Legal Signature
e-mail: sales@planet.com.tw http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528
Pages referenced in this manual — manufacturer, support and downloads.