EN
Planet Technology logo
Official user manual

Planet Technology ICS-100

63 pages·3.5 MB·TV Converter Box·PDF·ENDEFRITNLJA
Planet Technology ICS-100
Table of Contents 52 sections 1. INTRODUCTION · 1.1 Package Contents · 1.2 How to Use This Manual · 1.3 Product Description · … ShowHide
Page 1 of the Planet Technology ICS-100 user manual — User’s Manual ICS-100 / ICS-102 / ICS-102S15
Page 1 · click to enlarge
Page 1
Planet Technology ICS-100 diagram (page 1)
Fig. 1

User’s Manual ICS-100 / ICS-102 / ICS-102S15

RS-232/RS-422/RS-485 over 100Base-FX / 10/100Base-TX Media Converter

Page 2 of the Planet Technology ICS-100 user manual — FOR MODELS: ICS-100 / ICS-102 / ICS-102S15
Page 2 · click to enlarge
Page 2

Trademarks

Copyright © PLANET Technology Corp. 2008.

Contents subject to which revision without prior notice.

PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

Disclaimer

PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and

makes no warranty and representation, either implied or expressed, with respect to the quality, performance,

merchantability, or fitness for a particular purpose.

PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability for any

inaccuracies or omissions that may have occurred.

Information in this User's Manual is subject to change without notice and does not represent a commitment on the part of

PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User's Manual. PLANET

makes no commitment to update or keep current the information in this User's Manual, and reserves the right to make

improvements to this User's Manual and/or to the products described in this User's Manual, at any time without notice.

If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and

suggestions.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the

FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is

operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not

installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be

required to correct the interference at whose own expense.

CE Mark Warning

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user

may be required to take adequate measures.

WEEE Warning

To avoid the potential effects on the environment and human health as a result of the presence of

hazardous substances in electrical and electronic equipment, end users of electrical and electronic

equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of

WEEE as unsorted municipal waste and have to collect such WEEE separately.

Revision

PLANET RS-232/RS-422/RS-485 over 10/100Base-TX/100Base-FX Media Converter User's Manual

FOR MODELS: ICS-100 / ICS-102 / ICS-102S15

REVISION: 1.1 (APRIL.2008)

Part No.: 2080-AA3600-000

Page 5 of the Planet Technology ICS-100 user manual — 1.2 How to Use This Manual
Page 5 · click to enlarge
Page 5

1. INTRODUCTION

Thank you for purchasing PLANET Serial over Fast Ethernet Media Converter – ICS-10x series. Terms of “Serial Media

Converter” means the products mentioned titled in the cover page of this User’s manual

1.1 Package Contents

Open the box of the Serial Media Converter and carefully unpack it. The box should contain the following items:

Check the contents of your package for following parts:

„ Serial Media Converter x1

„ CD-ROM user's manual x1

„ Quick installation guide x1

„ External 5VDC / 2.5A power adapter x 1

If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the

original packing material, and use them against to repack the product in case there is a need to return it to us for repair.

1.2 How to Use This Manual

This Media Converter User Manual is structured as follows:

ƒ Section 2, Installation

It explains the functions of ICS-10x and how to physically install the ICS-10x.

ƒ Section 3, Management

The chapter explains how to manage the converter by Web interface.

ƒ Section 4, Web Configuration

It contains information about the Smart function of ICS-10x.

ƒ Section 5, Software VCOM Utility

It explains the software VCOM how to use with the operation Virtual COM.

It contains cable information of ICS-10x.

ƒ Appendices

Page 6 of the Planet Technology ICS-100 user manual — 1.4 Applications
Page 6 · click to enlarge
Page 6

1.3 Product Description

The Web-Smart ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485

communication interface over Fast Ethernet networking. There are RJ-45/SC connectors and

single-mode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily,

efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET

Media Converter Chassis (MC-700, MC-1000 and MC-1500). It’s time saving expense for user and SI, no need to

replace the existing Serial equipment and software system.

It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of

distance are flexibly provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable

and efficient network solutions based on the distance and budgets of installation.

The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a

TCP/IP networking immediately. Each Web-Smart converter is able to manage through the Web Interface. The powerful

Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc.

Management function helps reduce the amount of valuable time that a network administrator spends detecting and

locating network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection options

for large networking environment are available as well.

1.4 Applications

Access Control System – traditional installation

Most of the enterprise and government use access control plate and Mifare or RFID to authorize the entrance identity.

With traditional deploy, access control machine use RS-232 or RS-485 serial interface and cables connect to login server.

With connection to ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extend over

longer distances via fiber optical interface. The distance can be up to 20km in a local range. Or the ICS-10x can be linked

to a xDSL router to get the internet access capability; the access control can be set and monitored over the internet.

Planet Technology ICS-100 — 1.4 Applications diagram (page 6)
Fig. 2 · 1.4 Applications

Figure 1-1 Serial Converter for Access Control System application

Page 7 of the Planet Technology ICS-100 user manual — 1.3 Product Description
Page 7 · click to enlarge
Page 7

To monitor, configure and manage the Robot conveyer including other machines in a manufacturing, PLC (Programmable

Logical Control) is required. The PLC is used to drive above the manufacturing machines process. The ICS-10x can be set

to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast

Ethernet intranet to control the PLC, the administrator and workstation. There is no need to be always sets by the side of

the I/O machine.

Planet Technology ICS-100 — 1.3 Product Description diagram (page 7)
Fig. 3 · 1.3 Product Description

Figure 1-2 Serial Converter for factory PLC application

RTU Data Collect – UDP Mode

Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, signal and power utilization. ICS-10x

can be used to set-up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server

automatically.

Planet Technology ICS-100 — 1.3 Product Description diagram (page 7)
Fig. 4 · 1.3 Product Description

Figure 1-3 Serial Converter for factory RTU application

Process Control

Page 8 of the Planet Technology ICS-100 user manual — 1.5 Product Features
Page 8 · click to enlarge
Page 8

Surveillance motion control – Pair Connection Mode

Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232/RS-485 interfaces distance from

surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.

Planet Technology ICS-100 — 1.5 Product Features diagram (page 8)
Fig. 5 · 1.5 Product Features

Figure 1-4 Serial Converter for distance extend application

1.5 Product Features

„ One RS-232/422/485 port to one 10/100Base-TX or 100Base-FX Media Converter

„ Cost effective solution for RS-232 to Ethernet application

„ Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation

„ Asynchronous serial data rates up to 921600b/s

„ Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX standard

„ Supports auto MDI/MDI-X function on RJ-45 Port

„ Choice of fiber-connector from SC, multi-mode / single-mode fiber

„ Standard TCP/IP interface and versatile operation modes

„ Software Protocol Support ARP, ICMP,TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client

„ Built-in IP-Base Web interface for remote management

„ Serial Operation mode selected via Web management

„ Pair Connection mode for connecting two serial devices over a network

„ PLANET Smart Discovery utility automatically finds xxx devices on the network

„ Firmware upgrade via HTTP protocol

„ Compact size for easy Installation:

¾ Standalone - Wall mountable or DIN-Rail mounting (Optional accessory)

Show 4 more labels / short text on this page
Serial Interface · Ethernet Interface · Smart Functions · Hardware
Page 9 of the Planet Technology ICS-100 user manual — 1.6 PRODUCT SPECIFICATION
Page 9 · click to enlarge
Page 9

¾ Co-work with PLANET MC family Media Chassis ( MC-700/1000R/1500)

„ LED indicators for easy network diagnose

„ Reset Button at the front panel for reset to factory default

1.6 PRODUCT SPECIFICATION

Planet Technology ICS-100 — 1.6 PRODUCT SPECIFICATION diagram (page 9)
Fig. 6
RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND RS-485 (2-wire): Data+, Data-
Page 10 of the Planet Technology ICS-100 user manual — 1.6 PRODUCT SPECIFICATION
Page 10 · click to enlarge
Page 10
Planet Technology ICS-100 — 1.6 PRODUCT SPECIFICATION diagram (page 10)
Fig. 7
Dimension (W x D x H)97 x 70 x 26mm Weight200g Power SupplyExternal Power Adaptor 5V DC / 2A max. Power Consumption5.5 Watts (maximum) MechanicalMetal Operating Temperature: 0~50 Degree C Storage Temperature: -10~70 Degree C Humidity: 10%~90% RH (operating) 5%~90% RH (Storage) Environment EmissionsFCC Class A, CE Certification Class A IEEE 802.3 10Base-T IEEE 802.3u 100Base-TX / 100Base-FX EIA/TIA RS-232/422/485 Standards Regulatory ApprovalRoHS Compatible Media ConverterMC-700 / 1000R / 1500 Chassis Note.Reset Button at the rear panel for reset to factory default
Page 11 of the Planet Technology ICS-100 user manual — 2.1.1 Product Layout
Page 11 · click to enlarge
Page 11

2. INSTALLATION

This section describes the hardware features and installation of the ICS-10X’s components on the desktop or shelf. For

easier management and control of the ICS-10x, familiarize yourself with its display indicators, and ports. Front panel

illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Serial Media

Converter, please read this chapter completely.

2.1 Hardware Description

2.1.1 Product Layout

Figure 2-1 to Figure 2-4 show layout and front panel of ICS-10X.

„ ICS-100 – RS-232 / RS-422 / RS-485 over 10/100Base-TX

Planet Technology ICS-100 — 2.1.1 Product Layout diagram (page 11)
Fig. 8 · 2.1.1 Product Layout

Figure 2-1 ICS-100 panel layout

Page 12 of the Planet Technology ICS-100 user manual — 2. INSTALLATION
Page 12 · click to enlarge
Page 12
Planet Technology ICS-100 — 2. INSTALLATION diagram (page 12)
Fig. 9

Figure 2-2 PLANET ICS-100 Front Panel

„ ICS-102 / ICS-102S15 – RS-232 / RS-422 / RS-485 over 10/100Base-FX

Planet Technology ICS-100 — 2. INSTALLATION diagram (page 12)
Fig. 10

Figure 2-3 ICS-102 / ICS-102S15 panel layout

Planet Technology ICS-100 — 2. INSTALLATION diagram (page 12)
Fig. 11

Figure 2-4 PLANET ICS-102 Front Panel

Page 13 of the Planet Technology ICS-100 user manual — 9 RI
Page 13 · click to enlarge
Page 13

2.1.2 LED Indicators

Planet Technology ICS-100 — 2.1.2 LED Indicators diagram (page 13)
Fig. 12 · 2.1.2 LED Indicators

PWR Green Lights to indicate that the Converter is powered on.

Lights To indicate that the Fast Ethernet Port is successfully connecting to the network at 10Mbps or 100Mbps TP or Fiber Green

Blinks To indicate the Fast Ethernet Port is receiving or sending data

Lights To indicate that the UART Port is connected successfully Serial Green

Blinks To indicate the UART Port is receiving or sending data

2.1.3 DB9 Pin Define

„ DB9 Pin Define for RS-232 / RS-422 / RS-485

Planet Technology ICS-100 — 2.1.3 DB9 Pin Define diagram (page 13)
Fig. 13 · 2.1.3 DB9 Pin Define

9 RI

2.1.4 ICS-10X Rear Panel

The rear panel of the converter indicates one DC jack, which accepts input power with 5V DC 2.5A.

  • ICS-10x series
Planet Technology ICS-100 — 9 RI diagram (page 13)
Fig. 14

Figure 2-5 Rear Panel of ICS-10x

1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data loss or network downtime.

Power Notice:

2. In some area, installing a surge suppression device may also help to protect your Media Converter from being damaged by unregulated surge or current to the converter or the power adapter.
Page 14 of the Planet Technology ICS-100 user manual — 2.2.1 Stand-alone Installation
Page 14 · click to enlarge
Page 14

To press and release the RESET button. The ICS-10X will back to the factory default mode. Be sure that

you backup the current configuration of ICS-10X; else the entire configuration will be erased when

pressing the “RESET” button.

  • Press and release the RESET button shortly, the device will be rebooted.
  • Press the RESET button more than 10 seconds, the device will back to the factory default mode; the entire configuration will be erased.

2.2 Install the Converter

This section describes how to install your ICS-10X Web Smart Media Converter and make connections to the converter.

Please read the following topics and perform the procedures in the order being presented. The hardware installation of

PLANET ICS-10X Web Smart Media Converter do not need software configuration. To install your ICS-10X on a desktop

or shelf, simply complete the following steps.

2.2.1 Stand-alone Installation

To install an ICS-10X stand-alone, on a desktop or shelf, simply complete the following steps:

1. Turn off the power of the device/station in a network to which the ICS-10X will be attached.
2. Ensure that there is no activity in the network.
3. Attach RJ-45 / SC Fiber cable from the ICS-10X to the network.
4. Attach RS-232/RS-485 cable from the ICS-10X to the want to connect devices.
5. Connect the 5VDC power adapter to the ICS-10X and verify that the Power LED lights up.
6. Turn on the power of the device/station; the PWR LED (Green) should light when all cables are attached.
Planet Technology ICS-100 — 2.2.1 Stand-alone Installation diagram (page 14)
Fig. 15 · 2.2.1 Stand-alone Installation

Figure 2-6 ICS-100 stand alone installation

Page 15 of the Planet Technology ICS-100 user manual — 2.2.2 Chassis Installation and Rack Mounting
Page 15 · click to enlarge
Page 15
Planet Technology ICS-100 — 2.2.2 Chassis Installation and Rack Mounting diagram (page 15)
Fig. 16 · 2.2.2 Chassis Installation and Rack Mounting

Figure 2-7 ICS-102 / ICS-102S15 stand alone installation

Please refers to APPENDIX-A for detailed wiring information of the ICS-10X.

To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the

converter.

2.2.2 Chassis Installation and Rack Mounting

To install the Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described below.

1. Place your ICS-10X on a hard flat surface, with the front panel positioned towards your front side.
2. Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis.
Planet Technology ICS-100 — 2.2.2 Chassis Installation and Rack Mounting diagram (page 15)
Fig. 17 · 2.2.2 Chassis Installation and Rack Mounting

Figure 2-8 Insert a Media Converter into an available slot

3. Attach a rack-mount bracket to each side of the Chassis with supplied screws attached to the package.
Page 16 of the Planet Technology ICS-100 user manual — 2.2.2 Chassis Installation and Rack Mounting
Page 16 · click to enlarge
Page 16
4. After the brackets are attached to the chassis, use suitable screws to securely attach the brackets to the rack, as

shown in Figure 2-2.

5. Precede with the steps 4 and steps 5 of session 2.2.1 Stand-alone Installation to connect the network cabling

and supply power to your converter.

You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.

Planet Technology ICS-100 — 2.2.2 Chassis Installation and Rack Mounting diagram (page 16)
Fig. 18 · 2.2.2 Chassis Installation and Rack Mounting

Figure 2-9 Mounting the Chassis in a Rack

Page 17 of the Planet Technology ICS-100 user manual — 3.2 Requirements
Page 17 · click to enlarge
Page 17

3. MANAGEMENT

This chapter describes how to manage the ICS-10X. Topics include:

- Assigning an IP address to the ICS-10X

- Logging on to the ICS-10X

3.1 Overview

This chapter gives an overview of converter management. The ICS-10X provides a simply WEB browser interface.

Using this interface, you can perform various converter configuration and management activities, including:

„ Serial Port Configuration

Please refer to the following Chapter 4 for more details.

3.2 Requirements

  • Network cables.

For ICS-100: Use standard network (UTP) cables with RJ45 connectors.

For ICS-102 / ICS-102S15: Use Multi-mode or Single Mode fiber patch cord with SC connectors.

  • Subscriber PC installed with Ethernet NIC (Network Card)
  • Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS X or later, Linux, UNIX or

other platform compatible with TCP/IP protocols.

  • Above PC installed with WEB Browser, such as Microsoft Internet Explore or Mozilla Firefox

It is recommended to use Internet Explore 6.0 or above to access Serial Media Converter.

Show 5 more labels / short text on this page
- Overview · - Management methods · „ System · „ Network Configuration · „ Operation Mode
Page 18 of the Planet Technology ICS-100 user manual — 3.3.2 Login the Media converter
Page 18 · click to enlarge
Page 18

3.3 Management Methods

The way to manage the ICS-10X:

- Web Management via a network or dial-up connection

3.3.1 Web Management

The PLANET Web-Smart Media Converter provides a built-in browser interface. You can manage the ICS-10X remotely

by having a remote host with web browser, such as Microsoft Internet Explorer, Netscape Navigator or Mozilla Firefox.

Using this management method:

The ICS-10X must have an Internet Protocol (IP) address accessible for the remote host.

Planet Technology ICS-100 — 3.3.1 Web Management diagram (page 18)
Fig. 19 · 3.3.1 Web Management

Figure 3-1 Web Management over Ethernet

3.3.2 Login the Media converter

Before you start configure the ICS-10X, please note the ICS-10X is configured through an Ethernet connection, make sure

the manager PC must be set on same the IP subnet address.

For example, the default IP address of the ICS-10X is 192.168.0.100, then the manager PC should be set at 192.168.0.x

(where x is a number between 2 and 254), and the default subnet mask is 255.255.255.0.

1. Use Internet Explorer 6.0 or above Web browser. Enter IP address http://192.168.0.100 (the factory-default IP

address) to access the Web interface.

2. When the following login screen appears, please enter the default username and password (default user name and

password is "admin"). Press Login to enter the main screen of ICS-10X. The login screen in Figure 3-1 appears.

Default IP Address192.168.0.100
Default Accountadmin
Default Passwordadmin
Page 19 of the Planet Technology ICS-100 user manual — 3.3 Management Methods
Page 19 · click to enlarge
Page 19
Planet Technology ICS-100 — 3.3 Management Methods diagram (page 19)
Fig. 20 · 3.3 Management Methods

Figure 3-2 Login screen

1. For security reason, please change and memorize the new password after this first setup.
2. Only accept command in lowercase letter under web interface.
Page 20 of the Planet Technology ICS-100 user manual — 4.1 Main Menu
Page 20 · click to enlarge
Page 20

4. WEB CONFIGURATION

The ICS-10X Web Smart Media Converter provide Web interface for Converter smart function configuration and make the

Converter operate more effectively - They can be configured through the Web Browser. A network administrator can

manage and monitor the ICS-10x from the local LAN. This section indicates how to configure the Media Converter to

enable its smart function.

4.1 Main Menu

After a successful login, the main screen appears, the main screen displays the converter Welcome page. The screen in

Figure 4-1 appears.

Planet Technology ICS-100 — 4.1 Main Menu diagram (page 20)
Fig. 21 · 4.1 Main Menu

Figure 4-1 Web Main screen

As listed at the left of the main screen, the configurable smart functions are shown as below:

„ System – Check the hardware, software version and System MAC address and IP address of the converter. And the password changed firmware upgrade / Factory default / system reboot.

„ Network Configuration- Setup the IP address of the converter.

„ Operation Mode – Setup the serial port mode: “TCP server”, “TCP client”, “UDP client”, “Virtual COM”, “Telnet Server”, “Pair Connection – Remote (Master)” and “Pair Connection – Remote (Slave)”.

„ Serial Port Configuration- Setup the serial port value

Page 21 of the Planet Technology ICS-100 user manual — 4.2.1 System Information
Page 21 · click to enlarge
Page 21

4.2 System

4.2.1 System Information

The System Information page provides information for the current device. System Info page helps a network manager to

identify the versions and IP Address etc. The screen in Figure 4-2 appears.

Planet Technology ICS-100 — 4.2.1 System Information diagram (page 21)
Fig. 22 · 4.2.1 System Information

Figure 4-2 System Information screen

The page includes the following fields:

  • Model Name Specifies the device Model Name.
  • Software Version The current software version running on the device.
  • MAC Address Specifies the device MAC address.
  • IP Address The current IP Address of the device. The IP Address could be manual assigned. The factory default value is 192.168.0.100.
  • Subnet Mask The current IP Subnet Mask setting on the device. The factory default value is 255.255.255.0.
  • Gateway The default gateway for the IP interface. The factory default value is 192.168.0.254.
  • System Name The current IP Subnet Mask setting on the device.
  • Current Operation Mode

Show the current serial port operation mode.

Page 22 of the Planet Technology ICS-100 user manual — 4.2.2 Password Setting
Page 22 · click to enlarge
Page 22

4.2.2 Password Setting

This function provides administrator to secure Web login. The screen in Figure 4-3 appears.

Planet Technology ICS-100 — 4.2.2 Password Setting diagram (page 22)
Fig. 23 · 4.2.2 Password Setting

Figure 4-3 Password Setting screen

The page includes the following configurable data:

Login Name Displays the user name.

New Password Specifies the new password. The password is not displayed. As it entered an “y” corresponding to each character is displayed in the field.

(The maximum length is 15 characters)

Confirm Password This confirms the new password. The password entered into this field must be exactly the same as the password entered in the Password field.

After change the default password, if you forget the password. Please press and release the “Reset” button in the front panel of ICS-10X, the current setting will be lost and the ICS-10X will restore to the default mode.

Page 23 of the Planet Technology ICS-100 user manual — 4.2.3 Firmware upgrade
Page 23 · click to enlarge
Page 23

4.2.3 Firmware upgrade

The Firmware Upgrade page contains fields for downloading system image files from the Local File browser to the

device. The screen in Figure 4-4 appears.

Planet Technology ICS-100 — 4.2.3 Firmware upgrade diagram (page 23)
Fig. 24 · 4.2.3 Firmware upgrade

Figure 4-4 Firmware Upgrade screen

To open Firmware Upgrade screen perform the folling:

2. Click System -> Firmware Upgrade then click Load .
3. The Firmware Upgrade screen is displayed as in Figure 4-5.
Planet Technology ICS-100 — 4.2.3 Firmware upgrade diagram (page 23)
Fig. 25 · 4.2.3 Firmware upgrade

Figure 4-5 Firmware Upgrade screen

Page 24 of the Planet Technology ICS-100 user manual — 4.2.3 Firmware upgrade
Page 24 · click to enlarge
Page 24
4. Then the “Firmware Upgrade Mode” displayed as in Figure 4-6.
Planet Technology ICS-100 — 4.2.3 Firmware upgrade diagram (page 24)
Fig. 26 · 4.2.3 Firmware upgrade

Figure 4-6 Firmware Upgrade screen

Click the “Browse” button of the main page, the system would pop up the file selection menu to choose firmware.

Planet Technology ICS-100 — 4.2.3 Firmware upgrade diagram (page 24)
Fig. 27 · 4.2.3 Firmware upgrade

Figure 4-7 Windows file selection menu popup

5. Select on the firmware then click “ Upgrade ”. The firmware upgrade may take 60 seconds.

Do not power off the converter until the update progress is complete.

Do not quit the Firmware Upgrade page without press the “Upgrade” button - after the image is loaded. Or the system won’t apply the new firmware. Users have to repeat the firmware upgrade processes again.

Page 25 of the Planet Technology ICS-100 user manual — 4.2.5 System Reboot
Page 25 · click to enlarge
Page 25

4.2.4 Factory Default

The Factory Default can reset the ICS-10x back to the factory default mode. Be aware that the entire configuration will be

reset, and the IP address of the ICS-10x will be set to “192.168.0.100”. The screen in Figure 4-8 appears.

Planet Technology ICS-100 — 4.2.4 Factory Default diagram (page 25)
Fig. 28 · 4.2.4 Factory Default

Figure 4-8 Factory Default progress screen

4.2.5 System Reboot

The System Reboot can restart the ICS-10x. The screen in Figure 4-9 appears.

Planet Technology ICS-100 — 4.2.5 System Reboot diagram (page 25)
Fig. 29 · 4.2.5 System Reboot

Figure 4-9 System Reboot progress screen

Page 26 of the Planet Technology ICS-100 user manual — 4.3 Network Configuration
Page 26 · click to enlarge
Page 26

4.3 Network Configuration

This function allows setting the value for network configuration. The value is DHCP client, IP address, Subnet Mask,

Gateway, DNS and system name. Press the “Apply” button to set the value. The screen in Figure 4-10 appears.

Planet Technology ICS-100 — 4.3 Network Configuration diagram (page 26)
Fig. 30 · 4.3 Network Configuration

Figure 4-10 Network Configuration screen

The page includes the following configurable data:

  • DHCP Client Disable or enable the DHCP function.

When DHCP Client is set to “Enable”, the ICS-10x will send a DHCP request to the

DHCP server in the network. Once the DHCP Server get the request, it will assign a

dynamic IP address, netmask and gateway to the ICS-10x.

The factory default setting is “Disable”

  • IP Address Assign the converter IP Address.

The factory default value is 192.168.0.100

  • Subnet Mask Assign the converter Subnet Mask.

The factory default value is 255.255.255.0

  • Gateway Assign the converter gateway.

The factory default value is 192.168.0.254

  • DNS DNS is the way that Internet domain names are identified and translated into IP

addresses. A domain name is an alphanumeric name, such as planet.com, that it is

usually easier to remember. Assign the DNS server IP address.

  • System Name Allow set value for system name. (The maximum length is 15 characters).
Page 27 of the Planet Technology ICS-100 user manual — 4.4.1 TCP server mode
Page 27 · click to enlarge
Page 27

When DHCP Client is set to Enable, the IP Address, Subnet Mask, Gateway and DNS fields are not

allow to be changed.

If the Media Converter is set to DHCP Client enable, you can use PLANET Smart Discovery or

PLANET VCOM Utility to search the Media Converter which with DHCP assigned IP address.

4.4 Operation Mode

The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a TCP/IP

networking immediately. The ICS-10x allow traditional Computer/Client COM ports access to a serial equipment

anywhere on the Ethernet LAN network.

This Operation Mode configure page allows setup Serial interface operation mode as below:

„ Pair connection (local)

„ Pair connection (Master)

Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 27)
Fig. 31 · 4.4 Operation Mode

Figure 4-11 Operation Mode Configuration screen

Select the operation mode for the application and press the “Apply” button to take affect.

4.4.1 TCP server mode

When the ICS-10x be configured to TCP Server mode, it allows Serial device that connected to serial port of ICS-10x to establish TCP communication over Intranet or Internet network between:

„ Remote Host (Computer) with Serial applications using TCP/IP network socket programs

Show 5 more labels / short text on this page
„ TCP Server · „ TCP Client · „ UDP Client · „ Virtual COM · „ Telnet Server
Page 28 of the Planet Technology ICS-100 user manual — 4.4 Operation Mode
Page 28 · click to enlarge
Page 28

„ Other ICS-10x with TCP Client mode

It opens the TCP port of ICS-10x to wait for serial application to establish a TCP connection. After the connection is

established, data can be transmitted in both directions.

The parameter defines the maintenance status for listen for the TCP connection.

Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 28)
Fig. 32 · 4.4 Operation Mode

Figure 4-12 TCP Server mode

The screen in Figure 4-13 appears. When the changed operation mode, the user should be changed the Serial Port

Configuration.

Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 28)
Fig. 33 · 4.4 Operation Mode

Figure 4-13 TCP Server Configuration screen

The page includes the following fields:

  • Serial Port Operation Mode

Choose different mode:

„ Pair connection (local)

„ Pair connection (Master)

The default mode is “TCP Server”.

  • TCP Port Number The TCP port that ICS-10X uses to listen to connections and that other device must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the default is set to “1024” .
Show 5 more labels / short text on this page
„ TCP Server · „ TCP Client · „ UDP Client · „ Virtual COM · „ Telnet Server
Page 29 of the Planet Technology ICS-100 user manual — Setup Operation Mode and Serial Port of ICS-10x
Page 29 · click to enlarge
Page 29
  • Inactive Timeout Use the parameter to set an inactive timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. To disable the inactive timeout enter “0”.

Example: Use Microsoft Windows Hyper Terminal, TCP/IP Winsock mode

HyperTerminal is a program that you can use to connect to other computers, Telnet sites, online services, and host

computers, using either your modem, a null modem cable, a Console cable or Ethernet connection.

The users want to use the TCP Server mode to connect to a Ethernet Switch via Hyper Terminal, Winsock mode

1. Setup Operation Mode and Serial Port of ICS-10x
2. Hyper Terminal set up a new connection with the TCP/IP Winsock

Setup Operation Mode and Serial Port of ICS-10x

1. From the WEB interface, set the Serial operation mode of ICS-10x to “ TCP Server ” and set the TCP Port Number to

“23”.

Planet Technology ICS-100 — Setup Operation Mode and Serial Port of ICS-10x diagram (page 29)
Fig. 34 · Setup Operation Mode and Serial Port of ICS-10x
Figure 4-14 ExampleTCP Server Configuration screen
2. Set the Serial Port Configuration of ICS-10x as below:
ModeRS-232
Baudrare9600
Character Bits8
Parity Typenone
Stop Bit1
Hardware Flow Controlnone
Page 30 of the Planet Technology ICS-100 user manual — Hyper Terminal setup a new connection with TCP/IP Winsock
Page 30 · click to enlarge
Page 30
Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 30)
Fig. 35 · 4.4 Operation Mode
Figure 4-15 ExampleSerial Port Configuration screen

Hyper Terminal setup a new connection with TCP/IP Winsock

3. Open HyperTerminal
Planet Technology ICS-100 — Hyper Terminal setup a new connection with TCP/IP Winsock diagram (page 30)
Fig. 36 · Hyper Terminal setup a new connection with TCP/IP Wi…

Figure 4-16 Example Hyper Terminal screen

Page 31 of the Planet Technology ICS-100 user manual — 4.4 Operation Mode
Page 31 · click to enlarge
Page 31
4. On the File menu, click New Connection .
5. In the Name box, type a name that describes the connection.
6. In the Icon box, click the appropriate icon, and then click OK.
Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 31)
Fig. 37 · 4.4 Operation Mode
Figure 4-17 ExampleHyper Terminal – Create new connection
7. In the Connect To dialog box, choose which port or modem you want to use in the Connect using drop-down box.
Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 31)
Fig. 38 · 4.4 Operation Mode
Figure 4-18 ExampleHyper Terminal – Connect type
8. In this case we are connecting via TCP/IP (Winsock), enter the host address and port number, and then click OK.
9. If the Port Settings dialog box is displayed, complete the information, and click OK.
Page 32 of the Planet Technology ICS-100 user manual — 4.4 Operation Mode
Page 32 · click to enlarge
Page 32
Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 32)
Fig. 39 · 4.4 Operation Mode
Figure 4-19 ExampleHyper Terminal configuration

Host address The address or name of the connection you want to create. This can be in standard Internet

dotted notation (for example, w.x.y.z) or can be the site's user-friendly name.

port The number of the port that you want the connection to use. Port 23 is the default.

10. Then can use the console like connect the serial cable with the switch.
Planet Technology ICS-100 — 4.4 Operation Mode diagram (page 32)
Fig. 40 · 4.4 Operation Mode

Figure 4-20 TCP/IP Winsock connection screen

Value Description

Page 33 of the Planet Technology ICS-100 user manual — 4.4.2 TCP Client mode
Page 33 · click to enlarge
Page 33

4.4.2 TCP Client mode

When the ICS-10x be configured to TCP Client mode, it allows Serial device that connected to serial port of ICS-10x to

establish TCP communication actively over Intranet or Internet network between:

„ Remote Host (Computer) with Serial applications using TCP/IP network socket programs

„ Other ICS-10x with TCP Server mode

After the data has been transferred, the ICS-10x can disconnect automatically from the Remote Host depends on the TCP

Inactive timeout settings. The parameter defines the maintenance status for listen for the TCP connection.

Figure 4-21 TCP Client Mode

The screen in Figure 4-22 appears. When the changed operation mode, the user should be changed the Serial Port

Configuration.

Planet Technology ICS-100 — 4.4.2 TCP Client mode diagram (page 33)
Fig. 41 · 4.4.2 TCP Client mode

Figure 4-22 TCP Client Configuration screen

The page includes the following fields:

  • Remote Host IP Address

Allow the ICS-10X to connect actively to the remote host whose IP address is set by this parameter.

  • Remote Host Port Number

The remote host port number that ICS-10X uses to listen to connections and that other device must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the default is set to “1024”.

  • Inactive Timeout Use the parameter to set an inactive timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. To disable the inactive timeout enter “0”.
Page 34 of the Planet Technology ICS-100 user manual — 4.4.3 UDP Client mode
Page 34 · click to enlarge
Page 34

4.4.3 UDP Client mode

When the ICS-10x be configured to UDP Client mode, it allows Serial device that connected to serial port of ICS-10x to

quickly transmit data to multiple Remote Hosts over Intranet or Internet network by unicast or multicast. It also makes the Serial device to receive data from more than one Remote Hosts.

The parameter defines the maintenance status for listen for the UDP connection. In UDP Client mode, you need to define the remote IP Address and Local listen port number.

Planet Technology ICS-100 — 4.4.3 UDP Client mode diagram (page 34)
Fig. 42 · 4.4.3 UDP Client mode

Figure 4-23 UDP Client Mode

The screen in Figure 4-24 appears. When the changed operation mode, the user should be changed the Serial Port

Configuration.

Planet Technology ICS-100 — 4.4.3 UDP Client mode diagram (page 34)
Fig. 43 · 4.4.3 UDP Client mode

Figure 4-24 UDP Client Configuration screen

Page 35 of the Planet Technology ICS-100 user manual — 4.4.4 Virtual COM mode
Page 35 · click to enlarge
Page 35

The page includes the following fields:

  • Local UDP Port Enter the local port number
  • Remote Address Enter the IP address of the remote device.
  • Remote Port Enter the remote port number of the remote device.

4.4.4 Virtual COM mode

When the ICS-10x be configured to Virtual COM mode, it allows Serial device that connected to serial port of ICS-10x to establish TCP communication over Intranet or Internet network between Remote Host (Computer). The Virtual COM Port

driver has to be installed at the Remote Host. Users can send data by Virtual COM port, and Virtual COM port will transfer

data to Ethernet by windows socket. The Virtual COM driver maps IP Address / Port of ICS-10x to a local COM port on the

Remote Host (Computer). Once the Virtual COM connection is established, the applications work as the serial device is

direct connected to the Remote Host’s real COM port. After the connection is established, data can be transmitted in both

directions.

With connect to ICS-10x Serial over Fast Ethernet Converter, the serial devices are not limited to physical connection to

the PC/Remote Host COM port and able to be extension over longer distance. The parameter defines the maintenance

status for the Virtual COM.

Planet Technology ICS-100 — 4.4.4 Virtual COM mode diagram (page 35)
Fig. 44 · 4.4.4 Virtual COM mode

Figure 4-25 Virtual COM Mode

When the changed operation mode, the user should be changed the Serial Port Configuration. The screen in Figure 4-14

appears.

Planet Technology ICS-100 — 4.4.4 Virtual COM mode diagram (page 35)
Fig. 45 · 4.4.4 Virtual COM mode

Figure 4-26 Virtual COM Configuration screen

Page 36 of the Planet Technology ICS-100 user manual — Setup Operation Mode and Serial Port of ICS-10x
Page 36 · click to enlarge
Page 36

The page includes the following fields:

  • TCP Port Number The TCP port that ICS-10X uses to listen to connections and that other device

must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the

default is set to “1024”.

  • Inactive Timeout Use the parameter to set an inactive timeout. The unit drops the connection if

there is no activity on the serial line before the set time expires. To disable the

inactive timeout enter “0”.

ExampleUse PLANET VCOM Utility + Microsoft Windows Hyper terminal COM Port mode
Planet Technology ICS-100 — 4.4.4 Virtual COM mode diagram (page 36)
Fig. 46 · 4.4.4 Virtual COM mode

Figure 4-27 Example Virtual COM Mode

The user want to use the virtual COM like to use the serial cable connect the switch.

1. Setup Operation Mode and Serial Port of ICS-10x
2. Use PLANET VCOM Utility to create virtual COM Port
3. Hyper Terminal set up a new connection with the virtual COM port

Setup Operation Mode and Serial Port of ICS-10x

1. From the WEB interface, set the Serial operation mode of ICS-10x to “ Virtual COM ” and set the TCP Port Number

to “23”.

Page 37 of the Planet Technology ICS-100 user manual — 4.4.4 Virtual COM mode
Page 37 · click to enlarge
Page 37
Planet Technology ICS-100 — 4.4.4 Virtual COM mode diagram (page 37)
Fig. 47 · 4.4.4 Virtual COM mode
Figure 4-28 ExampleVirtual COM Configuration screen
2. Set the Serial Port Configuration of ICS-10x as below:
ModeRS-232
Baudrare9600
Character Bits8
Parity Typenone
Stop Bit1
Hardware Flow Controlnone
Figure 4-29 ExampleSerial Port Configuration screen
Page 38 of the Planet Technology ICS-100 user manual — VCOM Utility to create virtual COM port
Page 38 · click to enlarge
Page 38

VCOM Utility to create virtual COM port

3. This mode will run with the software-“ PLANET VCOM Utility ”. Open the VCOM utility, click “Search Device” to point out the ICS-10x that want to be configured.
Planet Technology ICS-100 — VCOM Utility to create virtual COM port diagram (page 38)
Fig. 48 · VCOM Utility to create virtual COM port
Figure 4-30 ExampleVirtual COM Configuration screen
4. Choose the VCOM tab and create COM 9 like below:
Planet Technology ICS-100 — VCOM Utility to create virtual COM port diagram (page 38)
Fig. 49 · VCOM Utility to create virtual COM port
Figure 4-31 ExampleVirtual COM Configuration screen
Page 39 of the Planet Technology ICS-100 user manual — Hyper Terminal setup a new connection with virtual COM port
Page 39 · click to enlarge
Page 39

Hyper Terminal setup a new connection with virtual COM port

5. On the File menu, click New Connection.
6. In the Name box, type a name that describes the connection.
7. In the Icon box, click the appropriate icon, and then click OK.
Planet Technology ICS-100 — Hyper Terminal setup a new connection with virtual COM port diagram (page 39)
Fig. 50 · Hyper Terminal setup a new connection with virtual C…
Figure 4-32 ExampleHyperTerminal Configuration screen
8. In the Connect to dialog box, choose which port you want to use in the Connect using drop-down box. In this case,

choose COM9 (as created in Step-4)

Planet Technology ICS-100 — Hyper Terminal setup a new connection with virtual COM port diagram (page 39)
Fig. 51 · Hyper Terminal setup a new connection with virtual C…
Figure 4-33 ExampleHyperTerminal Configuration screen
9. Set the parameter like below, click “Apply” to take effect.
Page 40 of the Planet Technology ICS-100 user manual — 4.4.4 Virtual COM mode
Page 40 · click to enlarge
Page 40
Planet Technology ICS-100 — 4.4.4 Virtual COM mode diagram (page 40)
Fig. 52 · 4.4.4 Virtual COM mode
Figure 4-34 ExampleHyperTerminal Com port properties screen
10. After the Virtual COM connection is established, open the VCOM utility again to check the COM9 information.
Planet Technology ICS-100 — 4.4.4 Virtual COM mode diagram (page 40)
Fig. 53 · 4.4.4 Virtual COM mode
Figure 4-35 ExampleVCOM Utility, COM9 information
11. Then can use the console like connect the serial cable with the switch.
Page 41 of the Planet Technology ICS-100 user manual — 4.4.5 Telnet Server mode
Page 41 · click to enlarge
Page 41
Planet Technology ICS-100 — 4.4.5 Telnet Server mode diagram (page 41)
Fig. 54 · 4.4.5 Telnet Server mode
Figure 4-36 ExampleHyper Terminal COM port screen

4.4.5 Telnet Server mode

TELNET (TELecommunication NETwork) is a network protocol used on the Internet or local area network (LAN)

connections. The Telnet protocol type is the correct setting for most servers and serial devices, such as Managed Ethernet

switches or Gateways. In most of the case, the telnet use TCP port 23 as communication port.

The parameter defines the maintenance status for Telnet server.

Planet Technology ICS-100 — 4.4.5 Telnet Server mode diagram (page 41)
Fig. 55 · 4.4.5 Telnet Server mode

Figure 4-37 Com port screen

When the changed operation mode, the user should be changed the Serial Port Configuration. The screen in Figure 4-38

appears.

Page 42 of the Planet Technology ICS-100 user manual — Example 1: Telnet Command in Windows Platform
Page 42 · click to enlarge
Page 42
Planet Technology ICS-100 — 4.4.5 Telnet Server mode diagram (page 42)
Fig. 56 · 4.4.5 Telnet Server mode

Figure 4-38 Telnet Server Configuration screen

The page includes the following fields:

  • TCP Port Number The TCP port that ICS-10X uses to listen to connections and that other device must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the default is set to “1024” .
  • Inactive Timeout Use the parameter to set an inactive timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. To disable the inactive timeout enter “0”.

The ICS-10X’s “telnet server mode”--if the user used the MS-DOS telnet command it will

show double character. So the user can use other Telnet software like: “putty” or “NetTerm”.

Example 1: Telnet Command in Windows Platform

Planet Technology ICS-100 — Example 1: Telnet Command in Windows Platform diagram (page 42)
Fig. 57 · Example 1: Telnet Command in Windows Platform

Figure 4-39 Example Telnet Server

Page 43 of the Planet Technology ICS-100 user manual — Execute “Telnet” command from Windows Start Menu
Page 43 · click to enlarge
Page 43

Setup Operation Mode and Serial Port of ICS-10x

1. Set the ICS-10X mode to “Telnet server mode ” from web interface.
2. Set the Serial Port Configuration of ICS-10x as below:
ModeRS-232
Baudrare9600
Character Bits8
Parity Typenone
Stop Bit1
Hardware Flow Controlnone

Execute “Telnet” command from Windows Start Menu

3. Click the Start Menu and go to Run
4. Type " telnet " without the quotes, and hit enter.
Planet Technology ICS-100 — Execute “Telnet” command from Windows Start Menu diagram (page 43)
Fig. 58 · Execute “Telnet” command from Windows Start Menu

Figure 4-40 Example Windows Excuse - Telnet

5. While the Telnet window appears, type “ open xxx,xxx,xxx,xxx ”, xxx is the IP address of the ICS-10x Telnet Server.

In this case we type “open 192.168.0.100” and press enter.

Planet Technology ICS-100 — Execute “Telnet” command from Windows Start Menu diagram (page 43)
Fig. 59 · Execute “Telnet” command from Windows Start Menu

Figure 4-41 Example Windows Excuse - Telnet

6. Then can use the telnet connection to configure the switch just like console direct connect to the COM port of the

switch.

Page 44 of the Planet Technology ICS-100 user manual — Example 2: Putty software in Windows Platform
Page 44 · click to enlarge
Page 44
Planet Technology ICS-100 — 4.4.5 Telnet Server mode diagram (page 44)
Fig. 60 · 4.4.5 Telnet Server mode

Figure 4-42 Example Windows Excuse - Telnet

7. To quit the Telnet session, press “CTRL+]” and then type “quit”
Planet Technology ICS-100 — 4.4.5 Telnet Server mode diagram (page 44)
Fig. 61 · 4.4.5 Telnet Server mode

Figure 4-43 Example Windows Excuse - Telnet

Example 2: Putty software in Windows Platform

PuTTY is a free implementation of Telnet and SSH for Win32 and Unix platforms, along with an xterm terminal emulator.

In this case we use Putty to telnet to the ICS-10x-Telnet Server mode for remote console login.

1. Set the ICS-10X mode to “Telnet server mode ” from web interface.
2. Run the Telnet software like “ Putty ” and set the parameter like below:
Page 45 of the Planet Technology ICS-100 user manual — 4.4.5 Telnet Server mode
Page 45 · click to enlarge
Page 45
Planet Technology ICS-100 — 4.4.5 Telnet Server mode diagram (page 45)
Fig. 62 · 4.4.5 Telnet Server mode

Figure 4-44 Putty Configuration screen

8. Then can telnet IP address like to telnet switch’s IP.
Planet Technology ICS-100 — 4.4.5 Telnet Server mode diagram (page 45)
Fig. 63 · 4.4.5 Telnet Server mode

Figure 4-45 Putty telnet screen

Page 46 of the Planet Technology ICS-100 user manual — 4.4.6 Pair Connection– Local mode
Page 46 · click to enlarge
Page 46

4.4.6 Pair Connection– Local mode

The parameter defines the maintenance status for listen for the pair connection. To make a long distance communication between two serial equipment, configure two ICS-10x with Pair Connection mode and setup one as a Master (Local side)

and the other as a Slave (Remote side).

„ Pair Connection – Local (Master) – the ICS-10x is locate close to the Host Computer or control device and

connect to it via serial interface.

„ Pair Connection – Remote (Slave) – the ICS-10x is locate close to the remote serial equipment and connect to it via serial interface..

Planet Technology ICS-100 — 4.4.6 Pair Connection– Local mode diagram (page 46)
Fig. 64 · 4.4.6 Pair Connection– Local mode

Figure 4-46 Pair Connection mode

In effect, this converter will be acting as a TCP server. The screen in Figure 4-46 appears. When the changed operation

mode, the user should be changed the Serial Port Configuration.

Planet Technology ICS-100 — 4.4.6 Pair Connection– Local mode diagram (page 46)
Fig. 65 · 4.4.6 Pair Connection– Local mode

Figure 4-47 Pair Connection – Local (Master) Configuration screen

  • TCP Port Number The TCP port that ICS-10X uses to listen to connections and that other device must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the default is set to “1024” .
  • Inactive Timeout Use the parameter to set an inactive timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. To disable the inactive timeout enter “0”.
Page 47 of the Planet Technology ICS-100 user manual — 4.4.7 Pair Connection – Remote mode
Page 47 · click to enlarge
Page 47

4.4.7 Pair Connection – Remote mode

The parameter defines the maintenance status for listen for the pair connection. In effect, this converter will be acting as a TCP client. The screen in Figure 4-48 appears.

When the changed operation mode, the user should be changed the Serial Port Configuration.

Planet Technology ICS-100 — 4.4.7 Pair Connection – Remote mode diagram (page 47)
Fig. 66 · 4.4.7 Pair Connection – Remote mode

Figure 4-48 Pair Connection – Remote (Slave) Configuration screen

  • TCP Port Number The TCP port that ICS-10X uses to listen to connections and that other device must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the default is set to “1024” .
  • Inactive Timeout Use the parameter to set an inactive timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. To disable the inactive timeout enter “0”.

While using Pair Connection mode for two RS-232 services distance extend, the DB9/RS-232 cables

are very importance in this application. There are much kind of RS-232 cables, such as straight cable

(standard) and Null-Modem cable. Please make sure the DB9/RS-232 cables match the below

constriction:

„ Serial Device to ICS-10x/Remote (Slave) – Use the original RS-232 serial cable attached in the

serial device package.

„ Host / Client to ICS-10x/Local (Master) – It has to use the Null-Modem cable!

Users can use the Null-Modem cable directly connect to the ICS-10x (Master), or use the Null-Modem

DB9 connector, as the picture shows:

Planet Technology ICS-100 — 4.4.7 Pair Connection – Remote mode diagram (page 47)
Fig. 67 · 4.4.7 Pair Connection – Remote mode
Planet Technology ICS-100 — 4.4.7 Pair Connection – Remote mode diagram (page 47)
Fig. 68 · 4.4.7 Pair Connection – Remote mode
Planet Technology ICS-100 — 4.4.7 Pair Connection – Remote mode diagram (page 47)
Fig. 69 · 4.4.7 Pair Connection – Remote mode

Once the Pair Connection mode of two ICS-10x be correctly configured but still fail link, check the RS-232 cables!

Page 48 of the Planet Technology ICS-100 user manual — Example: Two ICS-10x with Pair Connection mode
Page 48 · click to enlarge
Page 48

Example: Two ICS-10x with Pair Connection mode

One be configured as Pair Connection – Local (Master) The other one be configured as Pair Connection – Remote (Slave)

Via the RS-485 interface, the external scanners, speed dome cameras and PTZ receivers can be controlled by the

keyboard which provides upward, downward, leftward, rightward, clockwise and counterclockwise with the joystick. In this

case, we use two ICS-10x to extend the distance between an IP surveillance PT Camera and a Control keyboard. Both of

the two equipments are implemented with RS-485 interface.

The two of the ICS-10x master and slave with below settings:

Connect to Control Keyboard

IP Address / Subnet Mask 192.168.0.100 / 255.255.255.0

Operation Mode ModePair Connection – Local TCP Port Number : 1024

Serial Mode: RS-485 Baudrare: 9600 Character Bits: 8 Parity Type : none Stop Bit : 1 Hardware Flow Control: none

Connect to Speed Dome Camera, PTZ or Scanner

IP Address / Subnet Mask 192.168.0.101 / 255.255.255.0

Mode: Pair Connection – Remote Remote Host IP Address : 192.168.0.100 Remote Host Port Number : 1024

Serial Mode: RS-485 Baudrare: 9600 Character Bits: 8 Parity Type : none Stop Bit : 1 Hardware Flow Control: none

Topology:

Planet Technology ICS-100 — Example: Two ICS-10x with Pair Connection mode diagram (page 48)
Fig. 70 · Example: Two ICS-10x with Pair Connection mode

Figure 4-49 Two ICS-10x configured with Pair-Connection

Show 5 more labels / short text on this page
ICS-10x Master · Serial Port Configuration · ICS-10x Slave · Operation Mode · Serial Port Configuration
Page 49 of the Planet Technology ICS-100 user manual — ICS-10x – Slave: be configured to Pair-Connection-Remote
Page 49 · click to enlarge
Page 49
1. Connect the converter with the IP camera for RS-485 interface like PLANET product: “ICA-651”.
2. Connect the converter with the control keyboard for RS-485 interface like PLANET product: “CAM-KB300”.

ICS-10x – Master: be configured as Pair-Connection-Local

3. From Web interface, login the ICS-10x with IP address = 192.168.0.100, set up the operation mode of this unit to be

“ Pair Connection-Local (master)”

Figure 4-50 Pair Connection – Local, operation mode configuration

4. Set the Serial Port mode of ICS-10x-Master to RS-485 .

Figure 4-51 Pair Connection – Local, serial port configuration

ICS-10x – Slave: be configured to Pair-Connection-Remote

5. From Web interface, login the ICS-10x with IP address = 192.168.0.101, set up the operation mode of this unit to be

“ Pair Connection-Local (master)”

Page 50 of the Planet Technology ICS-100 user manual — 4.4.7 Pair Connection – Remote mode
Page 50 · click to enlarge
Page 50
Planet Technology ICS-100 — 4.4.7 Pair Connection – Remote mode diagram (page 50)
Fig. 71 · 4.4.7 Pair Connection – Remote mode

Figure 4-52 Pair Connection –Remote, operation mode configuration

6. Set the Serial Port mode of ICS-10x-Slave to RS-485 .

Figure 4-51 Pair Connection – Local, serial port configuration

7. Then the control keyboard cans remote control the IP camera.
Page 51 of the Planet Technology ICS-100 user manual — XON/XOFF, RTS/CTS, DTR/DSR
Page 51 · click to enlarge
Page 51

4.5 Serial Port Configuration

The page shows the converter’s serial Port configuration. The screen in Figure 4-52 appears.

Planet Technology ICS-100 — 4.5 Serial Port Configuration diagram (page 51)
Fig. 72 · 4.5 Serial Port Configuration

Figure 4-52 Converter Status page screen

The page includes the following fields:

  • Mode From the drop-down menu, select the serial port mode:

„ RS232 „ RS-422 „ RS-485

  • Baudrate The unit and attached serial device, such as a modem, must agree on a speed or baud rate to use for the serial connection, Valid baud rates. It’s in the range of 110bps to 921600bps .
  • Character Bits Indicates the number of the bits in a transmitted data package. The allowed value is 5 , 6 , 7 , 8

The default is “8”.

  • Parity type Checks for the parity type. The default value is “none” .
  • Stop Bit The stop bit follows the data and parity bits in serial communication. It indicates the end of transmission. The default is “1”.
  • Hardware Flow Control Flow control manages data flow between devices in a network to ensure it is processed efficiently. Too much data arriving before a device is prepared to manage it causes lost or retransmitted data.

XON/XOFF, RTS/CTS, DTR/DSR

The default value is “none”.

  • Delimiter Character The Character 1 and Character 2 allow the use to enter two ASCII character (in hex format) that delimit the beginning and end of a message. When a message with both there delimiters is received at the serial port, the data
Page 52 of the Planet Technology ICS-100 user manual — 4.5 Serial Port Configuration
Page 52 · click to enlarge
Page 52

contained in the serial buffer is paced in an Ethernet packet and sent out the Ethernet port.

Silent Time: For the defined period of time passed, the serial port stops data transmission and close the connection to remote host.

Drop Character: If the incoming data contain character 1 or character 2, the packet will be dropped

The default value is “Disable”

  • Logout

Press this function; the web interface will go back to login screen. The screens in Figure 4-53 and Figure 4-54 appear.

Planet Technology ICS-100 — 4.5 Serial Port Configuration diagram (page 52)
Fig. 73 · 4.5 Serial Port Configuration

Figure 4-53 Logout dialogues screen

Planet Technology ICS-100 — 4.5 Serial Port Configuration diagram (page 52)
Fig. 74 · 4.5 Serial Port Configuration

Figure 4-54 Login screen

Page 53 of the Planet Technology ICS-100 user manual — 5.1 Installing the VCOM Utility
Page 53 · click to enlarge
Page 53

5. SOFTWARE VCOM UTILITY

The ICS-10X Web Smart Media Converter provides software for Converter smart function configuration when the

Converter operation mode on “Virtual COM”. - They can be configured through the Console. Two function groups are

provide to easy used, can search device and create virtual COM to view as the console port.

This program can search ICS-10x Series devices, it will show information of the device. And user can use VCOM function

creates virtual com port for user using. Users can send data by virtual com port, and virtual com port will transfer data to

Ethernet by windows socket. While VCOM got data from Ethernet, it will transfer data to virtual com port by virtual com

component.

The VCOM is an integrated software suite that bundles Device Server Administrator and IP Serial Library, and provides

something you need to monitor your ICS-10X from a remote location.

5.1 Installing the VCOM Utility

1. Once the Setup program starts running, click Next when the Welcome window opens to proceed with the

installation.

Planet Technology ICS-100 — 5.1 Installing the VCOM Utility diagram (page 53)
Fig. 75 · 5.1 Installing the VCOM Utility

Figure 5-1 VCOM installation screen

2. Click Install to install the program.
Planet Technology ICS-100 — 5.1 Installing the VCOM Utility diagram (page 53)
Fig. 76 · 5.1 Installing the VCOM Utility

Figure 5-2 VCOM installation screen

Page 54 of the Planet Technology ICS-100 user manual — 5. SOFTWARE VCOM UTILITY
Page 54 · click to enlarge
Page 54
3. The Installing window reports the progress of the installation.
4. Click Finish to complete
Planet Technology ICS-100 — 5. SOFTWARE VCOM UTILITY diagram (page 54)
Fig. 77

Figure 5-3 VCOM installation screen

5. To run the PLANET VCOM utility on the computer, click “ Start ” \ “ Programs ” \ “ PLANET VOM Utility ” \ “ VCOM ”
Planet Technology ICS-100 — 5. SOFTWARE VCOM UTILITY diagram (page 54)
Fig. 78

Figure 5-4 VCOM program path

The VCOM contains two pagesSearch Device and VCOM. The Search Device has device information and the VCOM

show the virtual COM information.

Page 55 of the Planet Technology ICS-100 user manual — 5.3 Virtual COM
Page 55 · click to enlarge
Page 55

5.2 Search the Device

Click the Search Device button to find the ICS-10X. It will show the ICS-10X device name, project name, MAC address, IP

address, Sub Mask, Gateway and the connect port number.

1. Click the shortcut of VCOM on the desktop to run the VCOM program.
2. Click " Search Device " button in Search Device tab. If any ICS-10x series device on the LAN, it will show the device

name in the tree report. While user click the device name, it will show device information in the list report.

Planet Technology ICS-100 — 5.2 Search the Device diagram (page 55)
Fig. 79 · 5.2 Search the Device

Figure 5-5 VCOM Device Search

5.3 Virtual COM

This function should be set the ICS-10X’s operation mode to “Virtual COM” on the Web.

Choose to create port like below:

1. If the device support Telnet, while user click device name, it will show VCOM tab.
2. While user click VCOM tab, it will fill IP Address and Port number automatically.
3. Select COM Port Name
4. Click "Create Port" button to create new virtual com port and establish telenet connection
Page 56 of the Planet Technology ICS-100 user manual — 5.2 Search the Device
Page 56 · click to enlarge
Page 56

Figure 5-6 VCOM Configuration

5. Then set the HyperTerminal parameter

Figure 5-7 Hyper Terminal Configuration

6. then the VCOM will show connect information like below:
Page 57 of the Planet Technology ICS-100 user manual — 5.2 Search the Device
Page 57 · click to enlarge
Page 57

Figure 5-8 VCOM Configuration

7. Once the Virtual COM PortCOM9 connection is established, from the Windows Device Manager, a COM Port is

added to the device list.

Planet Technology ICS-100 — 5.2 Search the Device diagram (page 57)
Fig. 80 · 5.2 Search the Device

Figure 5-9 Windows Device Server - Virtual COM Port

When the Virtual COM create com port, the Device Manager will add “Virtual Serial Port”.

And delete the Port on the VCOM, the device will disappear.

Page 58 of the Planet Technology ICS-100 user manual — APPENDIX A
Page 58 · click to enlarge
Page 58

APPENDIX A

A.1 PLANET Smart Discovery Utility

For easily list the ICS-10X in your Ethernet environment, the Planet Smart Discovery Utility from user’s manual CD-ROM

is an ideal solution.

The following install instructions guiding you for run the Planet Smart Discovery Utility.

1. Deposit the Planet Smart Discovery Utility in administrator PC.
2. Run this utility and the following screen appears.
Planet Technology ICS-100 — APPENDIX A diagram (page 58)
Fig. 81

Figure A-1 Planet Smart Discovery Utility Screen

If there are two LAN cards or above in the same administrator PC, choose different LAN card by

use the “Select Adapter” tool.

3. Press “Refresh” button for list current connected devices in the discovery list, the screen is shown as follow.
Planet Technology ICS-100 — APPENDIX A diagram (page 58)
Fig. 82

Figure A-2 Planet Smart Discovery Utility Screen

Page 59 of the Planet Technology ICS-100 user manual — 9 RI
Page 59 · click to enlarge
Page 59
1. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version,

Device IP Subnet address, also can assign new password, IP Subnet address and description for the devices.

2. After setup completed, press “Update Device” , “Update Multi” or “Update All” button to take affect. The meaning of

the 3 buttons above are shown as below:

Update Device: use current setting on one single device.

Update Multi: use current setting on choose multi-devices.

Update All: use current setting on whole devices in the list.

The same functions mentioned above also can be finding in “Option” tools bar.

3. To click the “Control Packet Force Broadcast” function, it can allow assign new setting value to the Web Smart

Switch under different IP subnet address.

6. Press “Connect to Device” button then the Web login screen appears.
7. Press “Exit” button to shutdown the planet Smart Discovery Utility.

A.2 Device‘s RJ-232/RS-422/RS-485 Pin Assignments

¾ DB9 Pin Define for RS-232 / RS-422 / RS-485

Planet Technology ICS-100 — A.2 Device‘s RJ-232/RS-422/RS-485 Pin Assignments diagram (page 59)
Fig. 83 · A.2 Device‘s RJ-232/RS-422/RS-485 Pin Assignments

9 RI

A.3 Device‘s RJ-45 Pin Assignments

  • 10/100Mbps, 10/100Base-TX
Planet Technology ICS-100 — 9 RI diagram (page 59)
Fig. 84

Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly

forbidden, is beyond the scope of this standard.

Page 60 of the Planet Technology ICS-100 user manual — 1 2 3 4 5 6 7 8 SIDE 2
Page 60 · click to enlarge
Page 60

A.4 RJ-45 cable pin assignment

Planet Technology ICS-100 — A.4 RJ-45 cable pin assignment diagram (page 60)
Fig. 85 · A.4 RJ-45 cable pin assignment

There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection:

Planet Technology ICS-100 — A.4 RJ-45 cable pin assignment diagram (page 60)
Fig. 86 · A.4 RJ-45 cable pin assignment

SIDE 1 1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 SIDE 2

SIDE 1 1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 SIDE 2

8 = Brown Figure A-1Straight-Through and Crossover Cable

Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network.

Page 61 of the Planet Technology ICS-100 user manual — 2080-AA3600-000
Page 61 · click to enlarge
Page 61

A.5 Fiber Optical Cable Connection Parameter

The wiring details are as below:

  • Fiber Optical patch Cables: (For ICS-102 / ICS-102S)

Standard Fiber Type Cable Specification

Multi-mode 50/125μm or 62.5/125μm

Multi-mode 50/125μm or 62.5/125μm 100Base-FX

A.6 Power Information

The power jack of ICS-10X is with 2.5mm in the central post and required +5VDC power input. It will conform to the

bundled AC-DC adapter and Planet’s Media Chassis. Should you have the problem to make the power connection, please

contact your local sales representative.

Please keep the AC-DC adapter as spare parts when your ICS-10X is installed to a Media Chassis.

2.5mm

DC Receptacle 2.5mm

+5V for each slot

DC receptacle is 2.5mm wide that conforms to and matches the Media Converter 2.5mm DC jack's central post. Do not install any improper unit, model of the Media Converter

2080-AA3600-000

100Base-FX · (1300nm) · (1310nm) Single-mode 9/125μm

Page 62 of the Planet Technology ICS-100 user manual — PLANET TECHNOLOGY CORPORATION
Page 62 · click to enlarge
Page 62
Planet Technology ICS-100 — EC Declaration of Conformity diagram (page 62)
Fig. 87 · EC Declaration of Conformity

EC Declaration of Conformity For the following equipment: *Type of Product : RS-232 / RS-422 / RS-485 over 10/100Base-TX Media Converter (1 DB9, 1 RJ-45) *Model Number : ICS-100 * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien Taipei, Taiwan , R. O.C. is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (89/336/EEC). For the evaluation regarding the EMC, the following standards were applied:

Emission EN 55022 (1994 + A1:1995 + A2:1997 Class A) Harmonic EN 61000-3-2 (2000) Flicker EN 61000-3-3 (1995 + A1:2001) Immunity EN 55024 (1998) ESD IEC 61000-4-2 (1995 + A1:1998 + A2:2000) RS IEC 61000-4-3 (1995 + A1:1998 + A2:2000) EFT/ Burst IEC 61000-4-4 (1995 + A1:2000) Surge IEC 61000-4-5 (1995 + A1:2000) CS IEC 61000-4-6 (1996 + A1:2000) Magnetic Field IEC 61000-4-8 (1993 + A1:2000) Voltage Disp IEC 61000-4-11 (1994 + A1:2000)

Responsible for marking this declaration if the:

⌧ Manufacturer † Authorized representative established within the EU

Authorized representative established within the EU (if applicable):

Company Name: Planet Technology Corp.

Company Address: 11F, No.96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C

Person responsible for making this declaration

Name, Surname Kent Kang

Position / TitleProduct Manager

Taiwan 18, March., 2008 Place Date Legal Signature

PLANET TECHNOLOGY CORPORATION

e-mail: sales@planet.com.tw http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528

Page 63 of the Planet Technology ICS-100 user manual — PLANET TECHNOLOGY CORPORATION
Page 63 · click to enlarge
Page 63

EC Declaration of Conformity For the following equipment: *Type of Product : RS-232 / RS-422 / RS-485 over 100Base-FX Media Converter (1 DB9, 1 Fiber SC connector) *Model Number : ICS-102 / ICS-102S15 / ICS-105A * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien Taipei, Taiwan , R. O.C. is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (89/336/EEC). For the evaluation regarding the EMC, the following standards were applied:

Emission EN 55022 (1994 + A1:1995 + A2:1997 Class A) Harmonic EN 61000-3-2 (2000) Flicker EN 61000-3-3 (1995 + A1:2001) Immunity EN 55024 (1998) ESD IEC 61000-4-2 (1995 + A1:1998 + A2:2000) RS IEC 61000-4-3 (1995 + A1:1998 + A2:2000) EFT/ Burst IEC 61000-4-4 (1995 + A1:2000) Surge IEC 61000-4-5 (1995 + A1:2000) CS IEC 61000-4-6 (1996 + A1:2000) Magnetic Field IEC 61000-4-8 (1993 + A1:2000) Voltage Disp IEC 61000-4-11 (1994 + A1:2000)

Responsible for marking this declaration if the:

⌧ Manufacturer † Authorized representative established within the EU

Authorized representative established within the EU (if applicable):

Company Name: Planet Technology Corp.

Company Address: 11F, No.96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C

Person responsible for making this declaration

Name, Surname Kent Kang

Position / TitleProduct Manager

Taiwan 24, March., 2008 Place Date Legal Signature

PLANET TECHNOLOGY CORPORATION

e-mail: sales@planet.com.tw http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Display codes

Error codes

What the fault codes shown on the display mean and how to clear them.

CodeMeaningFix
RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND p.9
RS-422Tx+, Tx-, Rx+, Rx-, GND RS-485 (2-wire): Data+, Data- p.9

Ask about the Planet Technology ICS-100

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Planet Technology ICS-100

Be the first to ask — other owners or our team will answer.

Original document

Planet Technology ICS-100 manual PDF

63 pages·3.5 MB·TV Converter Box·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…