GT-902 GT-902S GT-905A GT-906A15 / GT-906B15 GT-906A60 / GT-906B60
10/100/1000Base-T to 1000Base-SX / LX
Managed Media Converter

Copyright © PLANET Technology Corp. 2008.
Contents subject to which revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.
PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and
makes no warranty and representation, either implied or expressed, with respect to the quality, performance,
merchantability, or fitness for a particular purpose.
PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability for any
inaccuracies or omissions that may have occurred.
Information in this User's Manual is subject to change without notice and does not represent a commitment on the part of
PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User's Manual. PLANET
makes no commitment to update or keep current the information in this User's Manual, and reserves the right to make
improvements to this User's Manual and/or to the products described in this User's Manual, at any time without notice.
If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and
suggestions.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at whose own expense.
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user
may be required to take adequate measures.
To avoid the potential effects on the environment and human health as a result of the presence of
hazardous substances in electrical and electronic equipment, end users of electrical and electronic
equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of
WEEE as unsorted municipal waste and have to collect such WEEE separately.
PLANET Managed Gigabit Ethernet Media Converter User's Manual
Part No.: 2080-AA3450-002



Check the contents of your package for following parts:
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the
original packing material, and use them against to repack the product in case there is a need to return it to us for repair.
#Notice: GT-905A is with one vacant SFP module slot. The 1000Base-SX / LX SFP module is not bundled
with in the package.
The Managed Media Converter User’s Manual is structured as followings:
Section 2, Hardware Installation
It explains the functions of Managed Media Converter and how to install the Managed Media Converter.
Section 3, Media Converter Management
It contains information about how to manage the Managed Media Converter.
Section 4, Web Management
It contains information about the management function from the Managed Media Converter.
It contains troubleshooting guide of Managed Media Converter.
It contains cable information of Managed Media Converter.
The term of “Managed Media Converter” In the following section of this user’s manual means the GT-90x.
Section 5, Troubleshooting · Appendix A

The Managed Media Converter GT-90x provide conversion between 10/100/1000Base-T and 1000Base-SX /LX network. There are SC / LC / WDM connectors and single-mode / multi-mode media for your needs. Ethernet signal that allows two
type segments connect easily, efficiently and inexpensively. This Managed Media Converter can be used as a stand-alone
unit or as a slide-in module to the PLANET Media Converter Chassis (MC-700, MC-1000 and MC-1500).
The Managed Media Converter equipped with remote Web / SNMP interface. With its built-in Web-based
management, the Managed Media Converter offers an easy-to-use, platform-independent management and
configuration facility and can be programmed for advanced management functions. Such as IP address Configuration
/ DHCP Client function, password setting / firmware upgrade, system reboot / factory default, port configuration that
include TP / Fiber port speed duplex mode setting, flow control setting and Ingress/Egress bandwidth control setting,
converter configuration that include maximum packet length setting, Broadcast / Multicast / Unicast storm control
setting, 16 IEEE 802.1Q VLAN groups support and powerful Q-in-Q VLAN function, Quality of Service (QoS), TS-1000
/ IEEE 802.3ah OAM function and TCP & UDP filter function. It supports standard Simple Network Management
Protocol (SNMP) and can be managed via any standard-based management software as well.
With Gigabit mini GBIC interface, the GT-905A is with high reliability and flexibility to extend the distance from 220m to
120Km. It depends on the Gigabit mini GBIC modules.
Fiber-optic Networking for ISP, enterprise, and home
With high performance of data transmission and easy installation, the Managed Media Converter can build an ISP network
solution of FTTH (Fiber to the Home) or FTTC (Fiber to the Curb) for ISPs and FTTB (Fiber to the Building) for small office
network environment from enterprises. The Web Management helps network administrators to monitor and setup the
converter, speed and duplex through web browsers.




Complies with IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z
One-channel media conversion between 10/100/1000Base-T and 1000Base-SX / LX
TP port supports 10/100/1000Base-T auto-negotiation and auto-MDI/MDI-X
1000Base-LX WDM interface for up to 15km (single-mode fiber 9μm/125μm) on GT-906A15/B15
1000Base-LX WDM interface for up to 60km (single-mode fiber 9μm/125μm) on GT-906A60/B60
Compacts size for working with PLANET MC family Media Chassis ( MC-700/1000R/1500)
Wall-mountable hardware designed
Built-in IP-Base Web interface for remote management
Layer 2 Management Feature
; Built-in Web operation interface for remote management and setup
; Manual IP address setting / DHCP client for IP address assignment
; SNMP v1 / v2c monitor / private Enterprise MIB
; Event trap and SNMP trap support
; Speed duplex mode configuration / Flow Control setting / bandwidth Control on TP / Fiber port
; Supports Port Status / Ethernet Statistics on both TP and Fiber interface
; Supports Maximum frame size to 16K bytes
; Loop detection / Broadcast / Multicast / Unicast storm control
; Management VLAN / 16 IEEE 802.1Q VLAN groups / Q-in-Q VLAN
; 802.1p Tag Priority / IP address priority / IP DSCP option in Quality of Service Mode and Strict Priority /
Weighted Round Robin (WRR) QoS policies
1000Base-SX/LX · ; Store-and-Forward mechanism

; TS-1000 OAM / IEEE 802.3ah OAM / Loop Back Test
; 16 TCP / UDP Filter groups
; Password setting, IP setting and devices description setting through Planet Smart discovery utility
; Firmware upgrade via remote Web interface
External DC5V 2A power supply
Compact in size, easy installation
LED indicators for easy network diagnosing
Reset Button at the front panel for resetting the factory default
Choice of fiber-connector from SC, LC, WDM, multi-mode / single-mode fiber /1000Base-SX / LX mini GBIC

Max. -4 dBm -3 dBm - -3 dBm +5 dBm -3 dBm +4 dBm Launch Power(dBm) Min. -9.5 dBm -9.5dBm - -9 dBm 0 dBm -9 dBm -1 dBm
dBm -14.4 dBm - -21 dBm -25 dBm -21 dBm -25 dBm
Maximum Input power -18 dBm -20 dBm - -3 dBm -3 dBm -2 dBm -2 dBm
50/125μm or 62.5/125μm multi-mode fiber cable, up to 220/550m. 9/125μm single-mode cable, provides long distance for 10/15/20/30/40/50/60/70/120km (very on fiber transceiver or SFP module) LED Indicator y PWR, y TP LINK/ACT, 1000 y Fiber LINK/ACT
module


This product provides three different running speeds – 10Mbps, 100Mbps and 1000Mbps in the same Managed Media
Converter and automatically distinguishes the speed of incoming connection.
This section describes the functionalities of GT-90X’s components and guides how to install it on the desktop or shelf.
Basic knowledge of networking is assumed. Please read this chapter completely before continuing.
The Front Panel of the Managed Media Converter consists of one 1000Base-SX / 1000Base-LX / mini-GBIC SFP /
1000Base-LX WDM ports and one Auto-Sensing 10/100/1000Mbps Ethernet RJ-45 Port. Figure 2-1 & 2-2 & 2-3 shows a
front panel of Managed Media Converter.

Figure 2-1 PLANET GT-902 / GT-902S Front Panel

Figure 2-2 PLANET GT-905A Front Panel

Figure 2-3 PLANET GT-906A/B Front Panel


Blink: Indicate that the Fiber port is actively sending or receiving data over that port.
Blink: Indicate that the port is actively sending or receiving data over that port.
Off: When the port runs in 10/100Mbps Half / Full duplex mode.
#Notice: To press and release the RESET button. The GX-90x will back to the factory default mode. Be
sure that you backup the current configuration of GT-90X; else the entire configuration will be
erased when pressing the “RESET” button.
The rear panel of the Managed Media Converter indicates one DC jack, which accepts input power with 5V DC 2A.

Figure 2-4 Rear Panel of GT-90x
Power Notice:
time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data
loss or network downtime.
damaged by unregulated surge or current to the converter or the power adapter.

This section describes how to install your Managed Media Converter and make connections to the Managed Media
Converter. Please read the following topics and perform the procedures in the order being presented. The hardware
installation of Managed Media Converter do not need software configuration. To install your Managed Media Converter on
a desktop or shelf, simply complete the following steps.

To install a Managed Media Converter stand-alone, on a desktop or shelf, simply complete the following steps:


#Notice: Please refers to APPENDIX-A for detailed wiring information of the Managed Media Converter.
To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the
converter.
GT-905A is with high reliability and flexibility to extend the distance from 220m to 120Km. It depends on the Gigabit mini
GBIC modules. The SFP transceivers are hot-plug and hot-swappable. You can plug-in and out the transceiver to/from
any SFP port without having to power down the converter.
To install GT-905A with 1000Base-SX / LX SFP, simply complete the following steps:
and supply power to your converter.
example: 1000Base-SX / 220m & 550m to 1000Base-SX / 220m & 550m, 1000Base-LX / 10km to 1000Base-LX /

It recommends using PLANET MGB series 1000Base-SX / LX / LX WDM SFP on the GT-905A. If you insert a SFP transceiver that is not supported, the GT-905A will not recognize it.
GT-905A Installation · 10km

To install the Managed Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described
below.
side.

shown in Figure 2-6.
and supply power to your Chassis.
You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.


Figure 2-6 Mounting the Chassis in a Rack

This chapter describes how to manage the Managed Media Converter. Topics include:
- Assigning an IP address to the Managed Media Converter
- Logging on to the Managed Media Converter
This chapter gives an overview of Managed Media Converter management. The GT-90X provides a simply WEB browser
interface. Using this interface, you can perform various Managed Media Converter configuration and management
activities, including:
Quality of Service
Please refer to the following Chapter 4 for more details.
The way to manage the GT-90X:
- Web Management via a network or dial-up connection.
-Using SNMP Network Management Station.

The PLANET Managed Media Converter provides a built-in browser interface. You can manage the Managed Media
Converter remotely by having a remote host with Web browser, such as Microsoft Internet Explorer, Netscape Navigator
or Mozilla Firefox.

The following shows how to startup the Web Management of the Managed Media Converter, please note the Managed
Media Converter is configured through an Ethernet connection, make sure the manager PC must be set on the same IP
subnet address, for example, the default IP address of the Managed Media Converter is 192.168.0.100 (the
factory-default IP address), then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254,
except 100), and the default subnet mask is 255.255.255.0.
Use Internet Explorer 5.0 or above Web browser, enter default IP address http://192.168.0.100
After entering the username and password (default user name and password is “admin”) in login screen then the Web
main screen appears.
You can manage the Managed Media Converter across a LAN using an SNMP Network Management Station with a
graphical user interface.
This management method lets you monitor statistical counters and set Managed Media Converter parameters from the
remote Network Management Station.
Using this management method:
- The network must run the IP protocol.
- The Managed Media Converter must have an IP address.

For easily list the Managed Media Converter in your Ethernet environment, the Planet Smart Discovery Utility from user’s
manual CD-ROM is an ideal solution.
The following install instructions guiding you for run the Planet Smart Discovery Utility.

Figure 3-1 Planet Smart Discovery Utility Screen
#Notice: If there are two LAN cards or above in the same administrator PC, choose different LAN card by
use the “Select Adapter” tool.

Figure 3-2 Planet Smart Discovery Utility Screen

Device IP Subnet address, also can assign new password, IP Subnet address and description for the devices.
the 3 buttons above are shown as below:
Update Device: use current setting on one single device.
Update Multi: use current setting on choose multi-devices.
Update All: use current setting on whole devices in the list.
The same functions mentioned above also can be finding in “Option” tools bar.
Converter under different IP subnet address.
Before you start configure the Managed Media Converter, please note the Managed Media Converter is configured
through an Ethernet connection, make sure the manager PC must be set on same the IP subnet address. For example,
the default IP address of the Managed Media Converter is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 2 and 254), and the default subnet mask is 255.255.255.0. Use Internet
Explorer 6.0 or above Web browser. Enter IP address http://192.168.0.100 (the factory-default IP address) to access the Web interface.
When the following login screen appears, please enter the default username and password (default user name and
password is "admin"). Press Login to enter the main screen of Managed Media Converter. The login screen in Figure 3-3 appears.

Figure 3-3 Login Web Page screen

The GT-90X Managed Media Converter provide Web interface for management function configuration and make the
Managed Media Converter operate more effectively - They can be configured through the Web Browser. A network
administrator can manage and monitor the Managed Media Converter from the local LAN. This section indicates how to
configure the Managed Media Converter to enable its management function.
After a successful login, the main screen appears, the main screen displays the Managed Media Converter Welcome
page. The screen in Figure 4-1 appears.

Figure 4-1 Web Main screen
As listed at the left of the main screen, the configurable management functions are shown as below:
◆ System – Provide System configuration of Managed Media Converter. Explained in section 4.2.
◆ Port Management – Provide Port Management configuration of Managed Media Converter. Explained in
section 4.3.
◆ Converter Configuration – Provide Converter configuration of Managed Media Converter. Explained in
section 4.4.
◆ VLAN – Provide VLAN configuration of Managed Media Converter. Explained in section 4.5.
◆ Quality of Service – Provide Quality of Service (QoS) function of the Managed Media Converter. Explained in
section 4.6.
◆ OAM Setup – Provide OAM Setup function of the Managed Media Converter. Explained in section 4.7.
◆ Security – Provide Security function of the Managed Media Converter. Explained in section 4.8.
◆ Logout– Provide Logout function of the Managed Media Converter. Explained in section 4.9.

The System Information Web page provides information for the current device. System Information Web page helps
network administrator to identify the firmware versions, IP Subnet Address and etc. The screen in Figure 4-2 appears and
Table 4-1 describes the System Information object of Managed Media Converter.

Figure 4-2 System Information Web page screen
The System Information Web page screen includes the following fields:
MAC Address Specifies the MAC address of Managed Media Converter.
Software Version The current software version running on the Managed Media Converter.
IP Address The current IP Address of Managed Media Converter, the default IP Address is 192.168.0.100.
Subnet Mask The current Subnet Mask of Managed Media Converter, the default Subnet Mask is 255.255.255.0.
Gateway The current gateway of Managed Media Converter, the factory default gateway is 192.168.0.254.
Description The current description of Managed Media Converter, the factory default description is GT-90X.
Table 4-1 Descriptions of the System Information Web Page Screen Objects

The IP Configuration includes the DHCP Client, IP Address, Subnet Mask, Gateway and Description. The screen in Figure
4-3 appears and Table 4-2 describes the IP Configuration object of Managed Media Converter.

Figure 4-3 IP Configuration Web page screen
The IP Configuration Web page screen includes the following configurable data:
DHCP Client Allow disable or enable the DHCP Client function of the Managed Media Converter, the factory default mode is Disable.
IP Address Allow assigning a new IP address for the Managed Media Converter, the factory default IP address is 192.168.0.100.
Subnet Mask Allow assigning a new subnet mask for the Managed Media Converter, the factory default subnet mask is 255.255.255.0.
Gateway Allow assigning a new gateway for the Managed Media Converter, the factory default gateway is 192.168.0.254.
Description Allow to input a new description for the Managed Media Converter, up to maximum 32 characters allow.
Apply button Press “Apply” button for save current configuration of Managed Media Converter.
Table 4-2 Descriptions of the IP Configuration Web Page Screen Objects
After change the default IP subnet address, if you forget the IP subnet address. Please press the “Reset” button in the front panel of Managed Media Converter for 10 seconds, the current setting will be lost and the Managed Media Converter will restore to factory default mode.

This function provides administrator to secure Web login. The screen in Figure 4-4 & 4-5 appears and Table 4-3 describes
the Password Setting object of Managed Media Converter.

Figure 4-4 Password Setting Web page screen

Figure 4-5 Password Setting Successful Web page screen

The Password Setting Web page includes the following configurable data:
Login Name Displays the user name (admin).
Old Password Enter the old password is required before entering the new password.
New Password Specifies the new password. The password is not displayed. As it entered an “y” corresponding to each character is displayed in the field.
(The maximum length is 16 characters)
Confirm This confirms the new password. The password entered into this field must be exactly the same as the password entered in the Password field.
Apply button Press “Apply” button for save current configuration of Managed Media Converter.
Table 4-3 Descriptions of the Password Setting Web Page Screen Objects
This function provides Firmware Upgrade of the Managed Media Converter and the screen in Figure 4-6 appears.

Figure 4-6 Firmware Upgrade Web page screen

Press “Browser” button to find the firmware location administrator PC, The screen in Figure 4-7 appears

Figure 4-7 Firmware Upgrade Web page screen
After find the firmware location from administrator PC, press “Upgrade” button to start the firmware upgrade process. The screen in Figure 4-8 & 4-9 appears.

Figure 4-8 Firmware Upgrade Web page screen


Figure 4-9 Firmware Upgrade Web page screen
When firmware upgrade process is completed then the following screen appears, please click “here” to re-login the Managed Media Converter with latest firmware and the screen in Figure 4-10 & 4-11 appears.

Figure 4-10 Firmware Upgrade Web page screen

Figure 4-11 Login Web page screen

This function provides SNMP Management and SNMP Trap Receiver Configuration function of the Managed Media
Converter and the screen in Figure 4-12 & 4-13 appears and Table 4-4 & 4-5 describes the SNMP Management and
SNMP Trap Receiver object of Managed Media Converter.

Figure 4-12 SNMP Management Web page screen
The SNMP Management Web page includes the following configurable data:
SNMP Agent Allow disable or enable the SNMP Agent function, the default mode is “Disable”.
SNMP Read Community Allow input the characters for SNMP Read Community, up to maximum 16 characters allow.
SNMP Write Community Allow input the characters for SNMP Write Community, up to maximum 16 characters allow.
System Name Allow input the characters for System Name, up to maximum 16 characters allow.
System Location Allow input the characters for System Location, up to maximum 16 characters allow.
Contact Allow input the characters for Contact person, up to maximum 16 characters allow.
Apply button Press “Apply” button for save current configuration of Managed Media Converter.
Table 4-4 Descriptions of the SNMP Management Web Page Screen Objects
#Notice: The GT-90x supports SNMP v1 / v2c.


Figure 4-13 SNMP Trap Receiver Configuration Web page screen
The SNMP Trap Receiver Configuration Web page includes the following configurable data:
SNMP Trap Allow disable or enable the SNMP Trap function, the default mode is “Disable”.
SNMP Trap Destination Allow input the IP address of SNMP Trap Destination.
Cold Start When Managed Media Converter executes Cold Start operation, the administrator PC (SNMP Trap Destination) will receive a Cold Start Trap.
Warm Start When Managed Media Converter executes Warm Start operation, the administrator PC (SNMP Trap Destination) will receive a Warm Start Trap.
Login Fail When Web login fail situation appears on Managed Media Converter, the administrator PC (SNMP Trap Destination) will receive a Login Fail Trap.
Link Up When TP or Fiber port connection is build up, the administrator PC (SNMP Trap Destination) will receive a Link Up Trap.
Link Down When TP or Fiber port connection is Disconnect, the administrator PC (SNMP Trap Destination) will receive a Link Down Trap.
Apply button Press “Apply” button for save current configuration of Managed Media Converter.
Table 4-5 Descriptions of the SNMP Trap Receiver Configuration Web Page Screen Objects
Trap Event

This function provides Factory Default function of the Managed Media Converter and the screen in Figure 4-14 & 4-15 &
4-16 appears.

Figure 4-14 Factory Default Web page screen

Figure 4-15 Factory Default Web page screen

Figure 4-16 Login Web page screen 4.2.7 System Reboot
This function provides System Reboot function of the Managed Media Converter and the screen in Figure 4-17 & 4-18 &
4-19 appears.

Figure 4-17 System Reboot Web page screen


Figure 4-18 System Reboot Web page screen
Figure 4-19 Login Web page screen

This function allows displaying TP / Fiber port status. The Link Status in the screen displays the current connection speed
and duplex mode; else this function will show red “Down” when the TP / Fiber port is disconnected. Press the “Refresh”
button to renew the screen. The screen in Figure 4-20 appears and Table 4-6 describes the Port Configuration object of
Managed Media Converter.

Figure 4-20 Port Configuration Web Page screen
The Port Configuration Web page includes the following configurable data:
Port Indicate the TP port and Fiber port.
Link Displays the current connection speed and duplex mode of TP or Fiber port.
Mode Allow configuring the TP or Fiber port speed and operation mode. Draw the menu bar to select the mode.
TP Port:
Default mode: Auto Speed.
Fiber Port:
Default mode: Auto Speed.

Flow Control Allow Disable or Enable Flow Control of TP or Fiber port.
Ingress Rate Limit The value of inbound traffic limitation in kilobit-per-second (kbps). The available options are :
The Ingress Rate Limit configuration field as show in Figure 4-21.
Egress Shaping The value of outbound traffic limitation in kilobit-per-second (kbps). The available options are :
The Egress Shaping configuration field as show in Figure 4-22.
Apply button Press this button for save current configuration of Managed Media Converter.
Refresh button Press “Refresh” button to refresh current status.
Table 4-6 Descriptions of the Port Configuration Web Page Screen Objects


Figure 4-21 Port Configuration-Ingress Rate Limit Web Page screen

Figure 4-22 Port Configuration-Egress Shaping Web Page screen

This function allows displaying TP / Fiber port detail status, such as Link Status, Duplex Mode, Flow control, Speed and
Auto negotiation. Press the “Refresh” button to renew the screen, the screen in Figure 4-23 appears and Table 4-7
describes the Port Status object of Managed Media Converter.

Figure 4-23 Port Status Web Page screen
The Port Status Web page includes the following configurable data:
Port Indicate the TP port and Fiber port.
Link Status Displays the current link status of TP and Fiber port.
Duplex Mode Displays the current duplex mode of TP and Fiber port.
Flow Control Displays the current Flow Control status of TP and Fiber port.
Speed Displays the current speed mode of TP and Fiber port.
Auto Negotiation Displays the current Auto negotiation status of TP and Fiber port.
Refresh button Press “Refresh” button to refresh current status.
Table 4-7 Descriptions of the Port Status Web Page Screen Objects

This function allows displaying TP / Fiber port detail Statistics, press the “Clear” button to clear current counter
information. Press the “Refresh” button to renew the screen, the screen in Figure 4-24 & 4-25 appears.

Figure 4-24 Port Statistics Web Page screen

Figure 4-25 Port Statistics Web Page screen

This function provides useful setting for the Managed Media Converter, such as Maximum Packet length, Loop detection,
storm control and etc. The screen in Figure 4-26 appears and Table 4-8 describes the Converter Configuration object of
Managed Media Converter.

Figure 4-26 Converter Configuration Web Page screen
The Converter Configuration Web page includes the following configurable data:
Maximum Packet Length Provide maximum packet length setting for the Managed Media Converter, the available options are 1518 bytes, 2048 bytes and 16K bytes. Default mode is 16K bytes.
Loop Detection Provide Disable or enable the Loop detection function. Default mode is Disable.
Loop Status Displays the Loop Detection status.
Broadcast Storm Control Provide Disable or enable the Broadcast Storm Control function. Default mode is Disable.
Multicast Storm Control Provide Disable or enable the Multicast Storm Control function. Default mode is Disable.
Unicast Storm Control Provide Disable or enable the Unicast Storm Control function. Default mode is Disable.
Storm Trigger Counter Provide storm Trigger Counter setting and the available options are:
Default mode is 64 broadcast.

Storm Filter Timer Provide storm Filter Timer setting and the available options are:
Default mode is 800ms.
Apply button Press this button for save current configuration of Managed Media Converter.
Table 4-8 Descriptions of the Converter Configuration Web Page Screen Objects
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you to isolate network traffic
so only members of the VLAN receive traffic from the same VLAN members. Basically, creating a VLAN from a converter
is logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network
devices are still plug into the same switch physically.
The Managed Media Converter supports IEEE 802.1Q (tagged-based) VLAN setting in web management page. In the
default configuration, VLAN support is “No VLAN”.
IEEE 802.1Q VLANs
IEEE 802.1Q (tagged) VLAN are implemented on the Managed Media Converter. 802.1Q VLAN require tagging, which
enables them to span the entire network (assuming all devices on the network are IEEE 802.1Q-compliant).
VLAN allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a VLAN will
only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN, and this includes
broadcast, multicast and unicast packets from unknown sources.
VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between stations
that are members of the VLAN. Any port can be configured as either tagging or untagging. The untagging feature of IEEE
802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging
feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows
Spanning Tree to be enabled on all ports and work normally.
Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allows VLAN to
work with legacy switches that don’t recognize VLAN tags in packet headers. The tagging feature allows VLAN to span
multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to be enabled on all
ports and work normally.
Some relevant terms:
Tag - The act of putting 802.1Q VLAN information into the header of a packet.
Untag - The act of stripping 802.1Q VLAN information out of the packet header.
802.1Q VLAN Tags
The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC address.
Their presence is indicated by a value of 0x8100 in the Ether Type field. When a packet's Ether Type field is equal to
0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets and consists of 3
bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring packets so they can be
carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user priority are used by 802.1p. The VID
is the VLAN identifier and is used by the 802.1Q standard. Because the VID is 12 bits long, 4094 unique VLAN can be
identified.
The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information originally
contained in the packet is retained.

802.1Q Tag
User Priority CFI VLAN ID (VID)
3 bits 1 bits 12 bits
TPID (Tag Protocol Identifier) TCI (Tag Control Information)
2 bytes 2 bytes
Source Address VLAN TAG Ethernet
6 bytes 6 bytes 4 bytes 2 bytes 46-1517 bytes 4 bytes
The Ether Type and VLAN ID are inserted after the MAC source address, but before the original Ether Type/Length or
Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic Redundancy Check (CRC)
must be recalculated.
Adding an IEEE802.1Q Tag
Dest. Addr. Src. Addr. Length/E. type Data Old CRC
Dest. Addr. Src. Addr. E. type Tag Length/E. type Data New CRC
Priority CFI VLAN ID
Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant network
device to another with the VLAN information intact. This allows 802.1Q VLAN to span network devices (and indeed, the
entire network – if all network devices are 802.1Q compliant).
Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the switch. If no VLAN
are defined on the switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged packets are
assigned the PVID of the port on which they were received. Forwarding decisions are based upon this PVID, in so far as
VLAN are concerned. Tagged packets are forwarded according to the VID contained within the tag. Tagged packets are
also assigned a PVID, but the PVID is not used to make packet forwarding decisions, the VID is.
Tag-aware switches must keep a table to relate PVID within the switch to VID on the network. The switch will compare the
VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VID are different the switch
will drop the packet. Because of the existence of the PVID for untagged packets and the VID for tagged packets,
tag-aware and tag-unaware network devices can coexist on the same network.
A switch port can have only one PVID, but can have as many VID as the switch has memory in its VLAN table to store
them.
Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware device
before packets are transmitted – should the packet to be transmitted have a tag or not? If the transmitting port is
connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to a tag-aware
device, the packet should be tagged.

The Managed Media Converter initially configures one VLAN, VID = 1, called "default." The factory default setting
assigns all ports on the Managed Media Converter to the "default". As new VLAN are configured in Port-based mode,
their respective member ports are removed from the "default."
This function allows disable or enable the IEEE 802.1Q VLAN operation mode. Press the “Apply” button to save the
current configuration of Managed Media Converter. The screen in Figure 4-27 & 4-28 appears and Table 4-9 describes the
VLAN Group object of Managed Media Converter.

Figure 4-27 VLAN Group Web Page screen
Default VLANs


Figure 4-28 VLAN Group Web Page screen
The VLAN Group Web page includes the following configurable data:
VLAN Mode Provide Disable or enable the IEEE 802.1Q VLAN operation mode. Default mode is Disable.
Management VLAN Group Provide define the Management VLAN group. Default mode is VLAN1.
VLAN Group Indicate the VLAN Group from 1 to 16.
VID Provide define the VLAN Group ID and the available options are 1 to 4094.
TP Provide assign TP port into VLAN Groups.
Fiber Provide assign Fiber port into VLAN Groups.
Apply button Press this button for save current configuration of Managed Media Converter.
Table 4-9 Descriptions of the VLAN Group Web Page Screen Objects
#Notice: When change the Management VLAN Group setting, please assure the TP or fiber port that
connect to administrator PC is in the same VLAN Group, otherwise, for further managed is impossible. The only solution is press the reset button 10 seconds for system reset to default mode.
Member

This function provides IEEE 802.1Q VLAN per port setting for TP and Fiber port of Managed Media Converter. Press the
“Apply” button to save the current configuration of Managed Media Converter. The screen in Figure 4-29 appears and
Table 4-10 describes the VLAN Per Port Setting object of Managed Media Converter.

Figure 4-29 VLAN Per Port Setting Web Page screen
The VLAN Per Port Setting Web page includes the following configurable data:
Port Indicate the TP port and Fiber port.
Egress Link Type Provide Egress Link Type options for TP port and Fiber port, the available options are:
Default mode is UnTag.
PVID Provide PVID assign for TP port and Fiber port, the available options are 1 to 4094. Default mode is 1 to 16.
Accept Frame Type Provide define the Accept Frame Type and the available options are
Default mode is All.
Ingress Filter Provide disable or enable the Ingress Filter function. Default mode is Enable.
Apply button Press this button for save current configuration of Managed Media Converter.
Table 4-10 Descriptions of the VLAN Per Port Setting Web Page Screen Objects

When enable Q-in-Q function, Managed Media Converter can insert or remove 4-bytes Q-in-Q tag in the received 802.3
frames after SA. User can define Q-in-Q tag value freely. And in default condition, Q-in-Q tag format is same as VLAN tag.
In normal application, enable two port’s Q-in-Q function. UTP Port set to insert QinQ tag and Fiber port set to remove
Q-in-Q Tag. For aggregation layer switch, it will check Q-in-Q tag only, not care about the VLAN tag from the corridor layer
switch. Q-in-Q Tag ether type can be set same as VLAN tag ether type or other values.
This function provides IEEE 802.1Q Q-in-Q VLAN setting of Managed Media Converter. Press the “Apply” button to save
the current configuration of Managed Media Converter. The screen in Figure 4-30 appears and Table 4-11 describes the
Q-in-Q VLAN setting object of Managed Media Converter.

Figure 4-30 Q-in-Q VLAN setting Web Page screen
The Q-in-Q VLAN setting Web page includes the following configurable data:
Q-in-Q Enable Provide disable or enable the Q-in-Q VLAN function. Default mode is Disable.
Q-in-Q direction Provide two directions for Q-in-Q function, the available options are:
UTP is customer port, Fiber is main port
Fiber is customer port, UTP is main port
Default mode is UTP is customer port, Fiber is main port.
Out Layer VLAN Tag EtherType (HEX)
Allow defined the Out Layer VLAN Tag EtherType and default mode is 0x8100.
Out Layer VLAN VID (DEC) Allow defined the Out Layer VLAN VID and default mode is 1.
Apply button Press this button for save current configuration of Managed Media Converter.
Table 4-11 Descriptions of the Q-in-Q VLAN setting Web Page Screen Objects

Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traffic.
QoS enables you to assign various grades of network service to different types of traffic, such as multi-media, video,
protocol-specific, time critical, and file-backup traffic.
QoS reduces bandwidth limitations, delay, loss, and jitter. It also provides increased reliability for delivery of your data and
allows you to prioritize certain applications across your network. You can define exactly how you want the switch to treat
selected applications and types of traffic.
You can use QoS on your system to:
。 Control a wide variety of network traffic by:
。 Classifying traffic based on packet attributes.
。 Assigning priorities to traffic (for example, to set higher priorities to time-critical or business-critical applications).
。 Applying security policy through traffic filtering.
。 Provide predictable throughput for multimedia applications such as video conferencing or voice over IP by
minimizing delay and jitter.
。 Improve performance for specific types of traffic and preserve performance as the amount of traffic grows.
。 Reduce the need to constantly add bandwidth to the network.
。 Manage network congestion.
This function provides Quality of Service setting of Managed Media Converter. Press the “Apply” button to save the
current configuration of Managed Media Converter. The screen in Figure 4-31 appears and Table 4-12 describes the
Quality of Service object of Managed Media Converter.

Figure 4-31 Quality of Service Web Page screen

The Quality of Service Web page includes the following configurable data:
Qos Mode Provide 4 different QoS mode for operation, the available options are:
802.1p Tag Priority
The 802.1p Tag Priority field as show in Figure 4-32.
The IP Address Priority field as show in Figure 4-33.
The IP DSCP Priority field as show in Figure 4-34.
Default mode is Disable.
Scheduling Provide two scheduling method for Quality of Service, the available options are:
Weighted Round Robin (16:8:4:1)
Default mode is Strict Priority.
Apply button Press this button for save current configuration of Managed Media Converter.
Table 4-12 Descriptions of the Quality of Service Web Page Screen Objects

Figure 4-32 802.1p Tag Priority Web Page screen


Figure 4-33 IP Address Priority Web Page screen

Figure 4-34 IP DSCP Priority Web Page screen

This function provides Local TS-1000 OAM Setup of Managed Media Converter. Press the “Apply” button to save the
current configuration of Managed Media Converter. The screen in Figure 4-35 appears and Table 4-13 describes the
Local TS-1000 OAM Setup object of Managed Media Converter.

Figure 4-35 Local TS-1000 OAM Setup Web Page screen
The Local TS-1000 OAM Setup Web page includes the following configurable data:
TS-1000 OAM State Provide disable or enable the TS-1000 OAM operation mode. Default mode is Disable.
TS-1000 Mode Provide two TS-1000 modes for operation, the available options are:
Default mode is Terminal.
Link Transparent Provide disable or enable the Link Transparent function. Default mode is Disable.
Link Transparent Result Display the link transparent result.
Apply button Press this button for save current configuration of Managed Media Converter.
Table 4-13 Descriptions of the Local TS-1000 OAM Setup Web Page Screen Objects
Terminal · Center

The Remote TS-1000 OAM Setup is an advanced remote device monitor feature that allows you to Remote monitor and
automatic notify status indication.
terminal Media Converter.
carries its current status.
change occurs in the status monitored internally by the terminal Media Converter.
notification indication, if any change occurs in the status monitored internally by the center Media Converter.
This function provides Remote TS-1000 OAM Setup of Managed Media Converter. Press the “Apply” button to save the
current configuration of Managed Media Converter. The screen in Figure 4-36 & 4-37 appears.

Figure 4-36 GT-80x Remote TS-1000 OAM Setup Web Page screen
Remote monitor · Autonomous notification


Figure 4-37 GT-90x Remote TS-1000 OAM Setup Web Page screen
#Notice: Please use the PLANET GT-80x and GT-90x as the Remote device.

The TS-1000 Loop Back Test allows manual run this loop back test to check the interconnection between two Media
Converter devices. To assure the Remote TS-1000 OAM function can work correctly.

In-band and out-band Loop back
OAM frame to center Media Converter.
generated from central Media Converter’s UTP port (Out-Band) or from central Media Converter (In-Band)
automatically.
This function provides TS-1000 Loop Back Test of Managed Media Converter. Press the “Apply” button to run Loop Back
Test and see the TS-1000 Loop Back Test Result of Managed Media Converter, also press the “Refresh” button to renew the Web screen. The screen in Figure 4-38 appears and Table 4-14 describes the TS-1000 Loop Back Test object of
Managed Media Converter.


Figure 4-38 Remote TS-1000 Loop Back Test Web Page screen
The TS-1000 Loop Back Test Web page includes the following configurable data:
TS-1000 Loop Back Test
Send Packet Number Allow input the number for packet send and the available options is 1 to 255. Default is 16.
Apply button Press this button for save current configuration of Managed Media Converter.
Refresh button Press “Refresh” button to refresh current status.
TS-1000 Loop Back Test Result
Result Display the TS-1000 Loop Back Test Result. Fail or Pass.
Result counter Display the value of Counter Result.
Table 4-14 Descriptions of the TS-1000 Loop Back Test Web Page Screen Objects
#Notice: Please use the PLANET GT-80x and GT-90x as the Remote device.

When enable 802.3ah OAM function, all 802.3ah OAMPDU packets will trap to embedded CPU.
Software will implement auto discovery procedure. With hardware support, software controls the 802.3ah remote loop
back procedure. Hardware can also detect dying gasp even and interrupt CPU to send dying gasp even notification
OAMPDU. All other functions defined by 802.3ah are implemented using embedded CPU.
When remote device is in loop back mode, hardware can support change looped test frame’s DA, SA or both as user
defined. Hardware can also set to don't change looped test frame.
This function provides 802.3ah Setup of Managed Media Converter. Press the “Apply” button to save the current
configuration of Managed Media Converter. The screen in Figure 4-39 appears and Table 4-15 describes the 802.3ah
Setup object of Managed Media Converter.

Figure 4-39 802.3ah Setup Web Page screen
The 802.3ah Setup Web page includes the following configurable data:
802.3ah OAM State Provide disable or enable the 802.3ah OAM State function. Default mode is Enable.
802.3ah OAM Mode Allow to choose “Active” or “Passive” for 802.3ah OAM Mode. Default mode is Passive.
Loopback Reply Provide disable or enable the Loopback Reply function. Default mode is Enable.
Remote OAM Configure Provide disable or enable the Remote OAM Configure function. Default mode is Enable.
Remote OAM Configuration Result
Display the Remote OAM Configuration Result.
Apply button Press this button for save current configuration of Managed Media Converter.
Table 4-15 Descriptions of the 802.3ah Setup Web Page Screen Objects

#Notice: 1. The 802.3ah function must work with manageable device that supports 802.3ah function.
The 802.3ah Loop Back Test allows manual run this loop back test to check the interconnection between two Media
Converter devices. To assure the Remote 802.3ah function can work correctly.
This function provides 802.3ah Loop Back Test of Managed Media Converter. Press the “Apply” button to run 802.3ah
Loop Back Test and see the 802.3ah Loop Back Test Result of Managed Media Converter, also press the “Refresh”
button to renew the Web screen. The screen in Figure 4-40 appears and Table 4-16 describes the 802.3ah Loop Back
Test object of Managed Media Converter.


Figure 4-40 802.3ah Loop Back Test Web Page screen
The 802.3ah Loop Back Test Web page includes the following configurable data:
802.3ah Loop Back Test
Send Packet Number Allow input the number for packet send and the available options is 1 to 255. Default is 16.
Packet Length (Not include CRC)
Allow input the number for Packet Length and the available options is 60 to 1514. Default is 60.
Apply button Press this button for save current configuration of Managed Media Converter.
Refresh button Press “Refresh” button to refresh current status.
802.3ah Loop Back Test Result
Result Display the 802.3ah Loop Back Test Result. Fail or Pass.
Table 4-16 Descriptions of the 802.3ah Loop Back Test Web Page Screen Objects
#Notice: 1. The 802.3ah function must work with manageable device that supports 802.3ah function.

This function provides TCP / UDP Filter setting of Managed Media Converter. Press the “Apply” button to save the
current configuration of Managed Media Converter. The screen in Figure 4-41 appears and Table 4-17 describes the TCP
/ UDP Filter setting object of Managed Media Converter.

Figure 4-41 Security setting Web Page screen
The Quality of Service Web page includes the following configurable data:
Group ID Provide input the group ID for TCP / UDP Filter and the available range is 1 to 16.
Action Provide “Deny” or “Permit” options and default mode is Permit.
Egress Port Provide choose “TP” or “Fiber” as Egress Port. Default mode is TP.
Packet Type Provide IPv4 and Non-IPv4 protocol for further setting.
L4 Protocol Provide IPv4 and Non-IPv4 protocol for further setting.
Current List Display current TCP / UDP Filter Groups.
Add button Press this button for add new TCP / UDP Filter group into current list.
Del button Press this button for delete existence TCP / UDP Filter group from current list.
Table 4-17 Descriptions of the Security setting Web Page Screen Objects

This function provides Logout function of Managed Media Converter, when the “Are you sure to logout” pop window
appears; press the “OK” button to logout Web page of Managed Media Converter. The screen in Figure 4-42 & 4-43 appears.

Figure 4-42 Logout Web Page screen
Figure 4-43 Login Web Page screen

This chapter contains information to help you solve problems. If the media converter is not functioning properly, make sure
the media converter was set up according to instructions in this manual.
Solution:
configuration.
Solution:
Check the full duplex status of the device. If the device is set to full duplex and the partner is set to half duplex, then
the performance will be poor.
10/100/1000Base-T port link LED is lit, but the traffic is irregular Solution:
Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to
change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.
Why the device doesn’t connect to the network
Solution:
Check the LNK/ACT LED on the Managed Media Converter .Try another port on the connected device. Make sure the
cable is installed properly Make sure the cable is the right type Turn off the power. After a while, turn on power again.
How to deal forgotten password situation of device?
Solution:
The Managed Media Converter is implemented with “Reset” button, press the button at the front panel about 10
seconds. After the device be rebooted. Login the Web Management page with default user name and password
(admin).

Hardware Reset



2 1 3 6
2 1 3 6
1 2 3 6
The standard RJ-45 receptacle/connector
10/100Mbps, 10/100Base-TX

There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection:

Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network.
The wiring details are as below:
Max. Distance
(MHz * km)
(meters)
1000Base-SX Multi-mode 62.5
Multi-mode 62.5
Single-mode 9 N/A 5000*
1000Base-LX

The power jack of Managed Media Converter is with 2.5mm in the central post and required +5VDC power input. It will
conform to the bundled AC-DC adapter and Planet’s Media Chassis. Should you have the problem to make the power
connection, please contact your local sales representative.
Please keep the AC-DC adapter as spare parts when your Managed Media Converter is installed to a Media Chassis.
2.5mm
DC Receptacle 2.5mm
+5V for each slot
DC receptacle is 2.5mm wide that conforms to and matches the Media Converter 2.5mm DC jack's central post. Do not install any improper unit, model of the Media Converter
The following list the available Modules for GT-905A
MGB-GT SFP-Port 1000Base-T mini-GBIC module
MGB-SX SFP-Port 1000Base-SX mini-GBIC module
MGB-LX SFP-Port 1000Base-LX mini-GBIC module
MGB-L30 SFP-Port 1000Base-LX mini-GBIC module -30KM
MGB-L50 SFP-Port 1000Base-LX mini-GBIC module -50KM
MGB-L70 SFP-Port 1000Base-LX mini-GBIC module -70KM
MGB-L120 SFP-Port 1000Base-LX mini-GBIC module -120KM
MGB-LA10 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1310nm), SM,10km
MGB-LB10 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1550nm), SM,10km
MGB-LA20 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1310nm), SM,20km
MGB-LB20 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1550nm), SM,20km
MGB-LA40 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1310nm), SM,40km
MGB-LB40 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1550nm), SM,40km


EC Declaration of Conformity For the following equipment: *Type of Product : 10/100/1000Base-T to 1000Base-SX/LX Managed Gigabit Converter *Model Number : GT-90xynn
x: can be 2,5,6; y: can be blank or S, A, B; nn: can be blank or 15,60 for different distance * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (89/336/EEC). For the evaluation regarding the EMC, the following standards were applied:
Emission EN 55022 (1994 + A1:1995 + A2:1997) Harmonic EN 61000-3-2 (2000) Flicker EN 61000-3-3 (1995 + A1:2001) Immunity EN 55024 (1998) ESD IEC 61000-4-2 (2001) RS IEC 61000-4-3 (1995) EFT/ Burst IEC 61000-4-4 (1995) Surge IEC 61000-4-5 (1995) CS IEC 61000-4-6 (1996) Magnetic Field IEC 61000-4-8 (1993) Voltage Disp IEC 61000-4-11 (1994)
⌧ Manufacturer Authorized representative established within the EU
Company Name: Planet Technology Corp.
Person responsible for making this declaration
Name, Surname Kent Kang
Taiwan 27, Oct., 2008 Place Date Legal Signature