EN
Planet Technology logo
Official user manual

Planet Technology GT-906B60

62 pages·5.5 MB·TV Converter Box·PDF·ENDEFRITNLJA
Planet Technology GT-906B60
Table of Contents 55 sections 1. INTRODUCTION · 1.1 Package Contents · 1.2 How to Use This Manual · 1.3 About the Managed Media Converter · … ShowHide
Page 1 of the Planet Technology GT-906B60 user manual — User's Manual
Page 1 · click to enlarge
Page 1
Planet Technology GT-906B60 diagram (page 1)
Fig. 1

User's Manual

GT-902 GT-902S GT-905A GT-906A15 / GT-906B15 GT-906A60 / GT-906B60

10/100/1000Base-T to 1000Base-SX / LX

Managed Media Converter

Page 2 of the Planet Technology GT-906B60 user manual — REVISION: 1.0 (OCTOBER.2008)
Page 2 · click to enlarge
Page 2

Trademarks

Copyright © PLANET Technology Corp. 2008.

Contents subject to which revision without prior notice.

PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.

Disclaimer

PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and

makes no warranty and representation, either implied or expressed, with respect to the quality, performance,

merchantability, or fitness for a particular purpose.

PLANET has made every effort to ensure that this User's Manual is accurate; PLANET disclaims liability for any

inaccuracies or omissions that may have occurred.

Information in this User's Manual is subject to change without notice and does not represent a commitment on the part of

PLANET. PLANET assumes no responsibility for any inaccuracies that may be contained in this User's Manual. PLANET

makes no commitment to update or keep current the information in this User's Manual, and reserves the right to make

improvements to this User's Manual and/or to the products described in this User's Manual, at any time without notice.

If you find information in this manual that is incorrect, misleading, or incomplete, we would appreciate your comments and

suggestions.

FCC Warning

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the

FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is

operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not

installed and used in accordance with the Instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be

required to correct the interference at whose own expense.

CE Mark Warning

This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user

may be required to take adequate measures.

WEEE Warning

To avoid the potential effects on the environment and human health as a result of the presence of

hazardous substances in electrical and electronic equipment, end users of electrical and electronic

equipment should understand the meaning of the crossed-out wheeled bin symbol. Do not dispose of

WEEE as unsorted municipal waste and have to collect such WEEE separately.

Revision

PLANET Managed Gigabit Ethernet Media Converter User's Manual

FOR MODELSGT-902 / GT-902S / GT-905A / GT-906A15 / GT-906B15 / GT-906A60 / GT-906B60

REVISION: 1.0 (OCTOBER.2008)

Part No.: 2080-AA3450-002

Page 3 of the Planet Technology GT-906B60 user manual — Table of contents
Page 3 · click to enlarge
Page 3

Table of contents

1. INTRODUCTIONp.51.1 Package Contentsp.51.2 How to Use This Manualp.51.3 About the Managed Media Converterp.61.4 Product Featuresp.71.5 PRODUCT SPECIFICATIONp.82. HARDWARE DESCRIPTIONp.102.1 GT-90X Front Panelp.102.1.1 LED Indicatorsp.112.1.2 GT-90X Rear Panelp.112.2 Install the Converterp.122.2.1 Stand-alone Installationp.122.2.2 Chassis Installation and Rack Mountingp.143. MEDIA CONVERTER MANAGEMENTp.163.1 Overviewp.163.2 Management Methodsp.163.2.1 Web Managementp.173.2.2 SNMP Managementp.173.2.3 PLANET Smart Discovery Utilityp.183.2.4 Login the Managed Media Converterp.194. WEB MANAGEMENTp.204.1 Main Menup.204.2 Systemp.214.2.1 System Informationp.214.2.2 IP Configurationp.224.2.3 Password Settingp.234.2.4 Firmware Upgradep.244.2.5 SNMP Managementp.284.2.6 Factory Defaultp.304.2.7 System Rebootp.314.3 Port Managementp.334.3.1 Port Configurationp.334.3.2 Port Statusp.364.3.3 Port Statisticsp.374.4 Converter Configurationp.384.5 VLANp.394.5.1 VLAN Groupp.414.5.2 VLAN Per Port Settingp.434.5.3 Q-in-Q VLAN Settingp.444.6 Quality of Servicep.454.7 OAM Setupp.484.7.1 Local TS-1000 OAM Setupp.484.7.2 Remote TS-1000 OAM Setupp.494.7.3 TS-1000 Loop Back Testp.514.7.4 802.3ah Setupp.534.7.5 802.3ah Loop Back Testp.544.8 Securityp.564.9 Logoutp.575. TROUBLESHOOTINGp.58APPENDIX A NETWORKING CONNECTIONp.59A.1 Device‘s RJ-45 Pin Assignmentsp.59A.2 RJ-45 cable pin assignmentp.59A.3 Fiber Optical Cable Connection Parameterp.60A.4 Power Informationp.61A.5 Available Modulesp.61
Page 4 of the Planet Technology GT-906B60 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

1. INTRODUCTIONp.51.1 Package Contentsp.51.2 How to Use This Manualp.51.3 About the Managed Media Converterp.61.4 Product Featuresp.71.5 PRODUCT SPECIFICATIONp.82. HARDWARE DESCRIPTIONp.102.1 GT-90X Front Panelp.102.1.1 LED Indicatorsp.112.1.2 GT-90X Rear Panelp.112.2 Install the Converterp.122.2.1 Stand-alone Installationp.122.2.2 Chassis Installation and Rack Mountingp.143. MEDIA CONVERTER MANAGEMENTp.163.1 Overviewp.163.2 Management Methodsp.163.2.1 Web Managementp.173.2.2 SNMP Managementp.173.2.3 PLANET Smart Discovery Utilityp.183.2.4 Login the Managed Media Converterp.194. WEB MANAGEMENTp.204.1 Main Menup.204.2 Systemp.214.2.1 System Informationp.214.2.2 IP Configurationp.224.2.3 Password Settingp.234.2.4 Firmware Upgradep.244.2.5 SNMP Managementp.284.2.6 Factory Defaultp.304.2.7 System Rebootp.314.3 Port Managementp.334.3.1 Port Configurationp.334.3.2 Port Statusp.364.3.3 Port Statisticsp.374.4 Converter Configurationp.384.5 VLANp.394.5.1 VLAN Groupp.414.5.2 VLAN Per Port Settingp.434.5.3 Q-in-Q VLAN Settingp.444.6 Quality of Servicep.454.7 OAM Setupp.484.7.1 Local TS-1000 OAM Setupp.484.7.2 Remote TS-1000 OAM Setupp.494.7.3 TS-1000 Loop Back Testp.514.7.4 802.3ah Setupp.534.7.5 802.3ah Loop Back Testp.544.8 Securityp.564.9 Logoutp.575. TROUBLESHOOTINGp.58APPENDIX A NETWORKING CONNECTIONp.59A.1 Device‘s RJ-45 Pin Assignmentsp.59A.2 RJ-45 cable pin assignmentp.59A.3 Fiber Optical Cable Connection Parameterp.60A.4 Power Informationp.61A.5 Available Modulesp.61
Page 5 of the Planet Technology GT-906B60 user manual — 1.2 How to Use This Manual
Page 5 · click to enlarge
Page 5

1. INTRODUCTION

1.1 Package Contents

Check the contents of your package for following parts:

  • Managed Gigabit Ethernet Media Converter x1
  • CD-ROM user's manual x1
  • Quick installation guide x1
  • External DC 5V / 2A power adapter x 1

If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the

original packing material, and use them against to repack the product in case there is a need to return it to us for repair.

#Notice: GT-905A is with one vacant SFP module slot. The 1000Base-SX / LX SFP module is not bundled

with in the package.

1.2 How to Use This Manual

The Managed Media Converter User’s Manual is structured as followings:

Section 2, Hardware Installation

It explains the functions of Managed Media Converter and how to install the Managed Media Converter.

Section 3, Media Converter Management

It contains information about how to manage the Managed Media Converter.

Section 4, Web Management

It contains information about the management function from the Managed Media Converter.

It contains troubleshooting guide of Managed Media Converter.

It contains cable information of Managed Media Converter.

The term of “Managed Media Converter” In the following section of this user’s manual means the GT-90x.

Section 5, Troubleshooting · Appendix A

Page 6 of the Planet Technology GT-906B60 user manual — 1.3 About the Managed Media Converter
Page 6 · click to enlarge
Page 6

1.3 About the Managed Media Converter

The Managed Media Converter GT-90x provide conversion between 10/100/1000Base-T and 1000Base-SX /LX network. There are SC / LC / WDM connectors and single-mode / multi-mode media for your needs. Ethernet signal that allows two

type segments connect easily, efficiently and inexpensively. This Managed Media Converter can be used as a stand-alone

unit or as a slide-in module to the PLANET Media Converter Chassis (MC-700, MC-1000 and MC-1500).

The Managed Media Converter equipped with remote Web / SNMP interface. With its built-in Web-based

management, the Managed Media Converter offers an easy-to-use, platform-independent management and

configuration facility and can be programmed for advanced management functions. Such as IP address Configuration

/ DHCP Client function, password setting / firmware upgrade, system reboot / factory default, port configuration that

include TP / Fiber port speed duplex mode setting, flow control setting and Ingress/Egress bandwidth control setting,

converter configuration that include maximum packet length setting, Broadcast / Multicast / Unicast storm control

setting, 16 IEEE 802.1Q VLAN groups support and powerful Q-in-Q VLAN function, Quality of Service (QoS), TS-1000

/ IEEE 802.3ah OAM function and TCP & UDP filter function. It supports standard Simple Network Management

Protocol (SNMP) and can be managed via any standard-based management software as well.

With Gigabit mini GBIC interface, the GT-905A is with high reliability and flexibility to extend the distance from 220m to

120Km. It depends on the Gigabit mini GBIC modules.

  • Application

Fiber-optic Networking for ISP, enterprise, and home

With high performance of data transmission and easy installation, the Managed Media Converter can build an ISP network

solution of FTTH (Fiber to the Home) or FTTC (Fiber to the Curb) for ISPs and FTTB (Fiber to the Building) for small office

network environment from enterprises. The Web Management helps network administrators to monitor and setup the

converter, speed and duplex through web browsers.

Planet Technology GT-906B60 — 1.3 About the Managed Media Converter diagram (page 6)
Fig. 2 · 1.3 About the Managed Media Converter
Page 7 of the Planet Technology GT-906B60 user manual — 1.4 Product Features
Page 7 · click to enlarge
Page 7
Planet Technology GT-906B60 — 1.4 Product Features diagram (page 7)
Fig. 3 · 1.4 Product Features
Planet Technology GT-906B60 — 1.4 Product Features diagram (page 7)
Fig. 4 · 1.4 Product Features

1.4 Product Features

† Complies with IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z

† One-channel media conversion between 10/100/1000Base-T and 1000Base-SX / LX

† TP port supports 10/100/1000Base-T auto-negotiation and auto-MDI/MDI-X

† 1000Base-SX50/125μm or 62.5/125μm multi-mode fiber cable, up to 220/550m on GT-902
† 1000Base-LX9/125μm single-mode cable provides long distance for 10km on GT-902S

† 1000Base-LX WDM interface for up to 15km (single-mode fiber 9μm/125μm) on GT-906A15/B15

† 1000Base-LX WDM interface for up to 60km (single-mode fiber 9μm/125μm) on GT-906A60/B60

† 1000Base-T2-pair Cat. 5/5e/6 UTP cable, up to 100 meters

† Compacts size for working with PLANET MC family Media Chassis ( MC-700/1000R/1500)

† Wall-mountable hardware designed

† Built-in IP-Base Web interface for remote management

† Layer 2 Management Feature

; Built-in Web operation interface for remote management and setup

; Manual IP address setting / DHCP client for IP address assignment

; SNMP v1 / v2c monitor / private Enterprise MIB

; Event trap and SNMP trap support

; Speed duplex mode configuration / Flow Control setting / bandwidth Control on TP / Fiber port

; Supports Port Status / Ethernet Statistics on both TP and Fiber interface

; Supports Maximum frame size to 16K bytes

; Loop detection / Broadcast / Multicast / Unicast storm control

; Management VLAN / 16 IEEE 802.1Q VLAN groups / Q-in-Q VLAN

; 802.1p Tag Priority / IP address priority / IP DSCP option in Quality of Service Mode and Strict Priority /

Weighted Round Robin (WRR) QoS policies

1000Base-SX/LX · ; Store-and-Forward mechanism

Page 8 of the Planet Technology GT-906B60 user manual — 1.5 PRODUCT SPECIFICATION
Page 8 · click to enlarge
Page 8

; TS-1000 OAM / IEEE 802.3ah OAM / Loop Back Test

; 16 TCP / UDP Filter groups

; Password setting, IP setting and devices description setting through Planet Smart discovery utility

; Firmware upgrade via remote Web interface

† External DC5V 2A power supply

† Compact in size, easy installation

† LED indicators for easy network diagnosing

† Reset Button at the front panel for resetting the factory default

† Choice of fiber-connector from SC, LC, WDM, multi-mode / single-mode fiber /1000Base-SX / LX mini GBIC

1.5 PRODUCT SPECIFICATION

Planet Technology GT-906B60 — 1.5 PRODUCT SPECIFICATION diagram (page 8)
Fig. 5

Max. -4 dBm -3 dBm - -3 dBm +5 dBm -3 dBm +4 dBm Launch Power(dBm) Min. -9.5 dBm -9.5dBm - -9 dBm 0 dBm -9 dBm -1 dBm

dBm -14.4 dBm - -21 dBm -25 dBm -21 dBm -25 dBm

Maximum Input power -18 dBm -20 dBm - -3 dBm -3 dBm -2 dBm -2 dBm

10Base-T2-pair UTP Cat. 3,4,5, up to 100 m
100Base-TX2-pair UTP Cat. 5, up to 100 m
1000Base-T4-pair STP Cat 5 up to 100m Cable

ƒ 50/125μm or 62.5/125μm multi-mode fiber cable, up to 220/550m. ƒ 9/125μm single-mode cable, provides long distance for 10/15/20/30/40/50/60/70/120km (very on fiber transceiver or SFP module) LED Indicator y PWR, y TP LINK/ACT, 1000 y Fiber LINK/ACT

module

Page 9 of the Planet Technology GT-906B60 user manual — 1.5 PRODUCT SPECIFICATION
Page 9 · click to enlarge
Page 9
Power Consumption3.8 Watts/ 13 BTU (maximum) Power InputDC 5V / 2A Dimensions94 x 70 x 26mm (W x D x H) Operator EnvironmentOperating temperature: 0 to 50 Degree C; Humidity: 5~90% non-condensing Storage Environmentstorage temperature: -40 to 70 Degree C; Humidity: 5~90% non-condensing EmissionsFCC Class A, CE Class A
Page 10 of the Planet Technology GT-906B60 user manual — 2.1 GT-90X Front Panel
Page 10 · click to enlarge
Page 10

2. HARDWARE DESCRIPTION

This product provides three different running speeds – 10Mbps, 100Mbps and 1000Mbps in the same Managed Media

Converter and automatically distinguishes the speed of incoming connection.

This section describes the functionalities of GT-90X’s components and guides how to install it on the desktop or shelf.

Basic knowledge of networking is assumed. Please read this chapter completely before continuing.

2.1 GT-90X Front Panel

The Front Panel of the Managed Media Converter consists of one 1000Base-SX / 1000Base-LX / mini-GBIC SFP /

1000Base-LX WDM ports and one Auto-Sensing 10/100/1000Mbps Ethernet RJ-45 Port. Figure 2-1 & 2-2 & 2-3 shows a

front panel of Managed Media Converter.

Planet Technology GT-906B60 — 2.1 GT-90X Front Panel diagram (page 10)
Fig. 6 · 2.1 GT-90X Front Panel

Figure 2-1 PLANET GT-902 / GT-902S Front Panel

Planet Technology GT-906B60 — 2.1 GT-90X Front Panel diagram (page 10)
Fig. 7 · 2.1 GT-90X Front Panel

Figure 2-2 PLANET GT-905A Front Panel

Planet Technology GT-906B60 — 2.1 GT-90X Front Panel diagram (page 10)
Fig. 8 · 2.1 GT-90X Front Panel

Figure 2-3 PLANET GT-906A/B Front Panel

Page 11 of the Planet Technology GT-906B60 user manual — 2.1.2 GT-90X Rear Panel
Page 11 · click to enlarge
Page 11

2.1.1 LED Indicators

Planet Technology GT-906B60 — 2.1.1 LED Indicators diagram (page 11)
Fig. 9 · 2.1.1 LED Indicators
LitTo indicate the link through that fiber port is successfully established. Fiber LNK/ACT Green

Blink: Indicate that the Fiber port is actively sending or receiving data over that port.

LitTo indicate the link through that port is successfully established. TP LNK/ACT Green

Blink: Indicate that the port is actively sending or receiving data over that port.

LitWhen the port runs in 1000Mbps Full duplex mode TP 1000 Green

Off: When the port runs in 10/100Mbps Half / Full duplex mode.

#Notice: To press and release the RESET button. The GX-90x will back to the factory default mode. Be

sure that you backup the current configuration of GT-90X; else the entire configuration will be

erased when pressing the “RESET” button.

  • Press and release the RESET button shortly, the device will be rebooted.
  • Press the RESET button more than 10 seconds, the device will back to the factory default mode; the entire configuration will be erased.

2.1.2 GT-90X Rear Panel

The rear panel of the Managed Media Converter indicates one DC jack, which accepts input power with 5V DC 2A.

  • GT-90x series
Planet Technology GT-906B60 — 2.1.2 GT-90X Rear Panel diagram (page 11)
Fig. 10 · 2.1.2 GT-90X Rear Panel

Figure 2-4 Rear Panel of GT-90x

Power Notice:

1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the

time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data

loss or network downtime.

2. In some area, installing a surge suppression device may also help to protect your Managed Media Converter from being

damaged by unregulated surge or current to the converter or the power adapter.

Page 12 of the Planet Technology GT-906B60 user manual — 2.2.1 Stand-alone Installation
Page 12 · click to enlarge
Page 12

2.2 Install the Converter

This section describes how to install your Managed Media Converter and make connections to the Managed Media

Converter. Please read the following topics and perform the procedures in the order being presented. The hardware

installation of Managed Media Converter do not need software configuration. To install your Managed Media Converter on

a desktop or shelf, simply complete the following steps.

Planet Technology GT-906B60 — 2.2 Install the Converter diagram (page 12)
Fig. 11 · 2.2 Install the Converter

2.2.1 Stand-alone Installation

To install a Managed Media Converter stand-alone, on a desktop or shelf, simply complete the following steps:

1. Turn off the power of the device/station in a network to which the Managed Media Converter will be attached.
2. Ensure that there is no activity in the network.
3. Attach fiber cable from the Managed Media Converter to the fiber network. TX, RX must be paired at both ends.
4. Connect the 5VDC power adapter to the Managed Media Converter and verify that the Power LED lights up.
5. Turn on the power of the device/station; the PWR LEDs should light when all cables are attached.
Planet Technology GT-906B60 — 2.2.1 Stand-alone Installation diagram (page 12)
Fig. 12 · 2.2.1 Stand-alone Installation
Page 13 of the Planet Technology GT-906B60 user manual — # Notice:
Page 13 · click to enlarge
Page 13

#Notice: Please refers to APPENDIX-A for detailed wiring information of the Managed Media Converter.

To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the

converter.

GT-905A is with high reliability and flexibility to extend the distance from 220m to 120Km. It depends on the Gigabit mini

GBIC modules. The SFP transceivers are hot-plug and hot-swappable. You can plug-in and out the transceiver to/from

any SFP port without having to power down the converter.

To install GT-905A with 1000Base-SX / LX SFP, simply complete the following steps:

1. Precede with the steps 4 and steps 5 of session 2.2.1 Stand-alone Installation to connect the network cabling

and supply power to your converter.

2. Slot in the 1000Base-SX / LX SFP. Make sure both side of the SFP transceiver are with the same media type, for

example: 1000Base-SX / 220m & 550m to 1000Base-SX / 220m & 550m, 1000Base-LX / 10km to 1000Base-LX /

Planet Technology GT-906B60 — 2.2 Install the Converter diagram (page 13)
Fig. 13 · 2.2 Install the Converter
3. Connect the fiber cable. Attach the duplex LC connector on the network cable into the SFP transceiver.

# Notice:

It recommends using PLANET MGB series 1000Base-SX / LX / LX WDM SFP on the GT-905A. If you insert a SFP transceiver that is not supported, the GT-905A will not recognize it.

„ GT-905A Installation · 10km

Page 14 of the Planet Technology GT-906B60 user manual — 2.2.2 Chassis Installation and Rack Mounting
Page 14 · click to enlarge
Page 14

2.2.2 Chassis Installation and Rack Mounting

To install the Managed Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described

below.

1. Place your Managed Media Converter on a hard flat surface, with the front panel positioned towards your front

side.

2. Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis.
Planet Technology GT-906B60 — 2.2.2 Chassis Installation and Rack Mounting diagram (page 14)
Fig. 14 · 2.2.2 Chassis Installation and Rack Mounting
Figure 2-5Insert a Managed Media Converter into an available slot
3. Attach a rack-mount bracket to each side of the Chassis with supplied screws attached to the package.
4. After the brackets are attached to the chassis, use suitable screws to securely attach the brackets to the rack, as

shown in Figure 2-6.

5. Precede with the steps 4 and steps 5 of session 2.2.1 Stand-alone Installation to connect the network cabling

and supply power to your Chassis.

You must use the screws supplied with the mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.

Page 15 of the Planet Technology GT-906B60 user manual — 2.2.2 Chassis Installation and Rack Mounting
Page 15 · click to enlarge
Page 15
Planet Technology GT-906B60 — 2.2.2 Chassis Installation and Rack Mounting diagram (page 15)
Fig. 15 · 2.2.2 Chassis Installation and Rack Mounting

Figure 2-6 Mounting the Chassis in a Rack

Page 16 of the Planet Technology GT-906B60 user manual — 3.2 Management Methods
Page 16 · click to enlarge
Page 16

3. MEDIA CONVERTER MANAGEMENT

This chapter describes how to manage the Managed Media Converter. Topics include:

- Assigning an IP address to the Managed Media Converter

- Logging on to the Managed Media Converter

3.1 Overview

This chapter gives an overview of Managed Media Converter management. The GT-90X provides a simply WEB browser

interface. Using this interface, you can perform various Managed Media Converter configuration and management

activities, including:

„ VLAN

„ Quality of Service

Please refer to the following Chapter 4 for more details.

3.2 Management Methods

The way to manage the GT-90X:

- Web Management via a network or dial-up connection.

-Using SNMP Network Management Station.

Show 8 more labels / short text on this page
- Overview · - Management methods · „ System · „ Port Management · „ Converter Configuration · „ OAM Setup · „ Security · „ Logout
Page 17 of the Planet Technology GT-906B60 user manual — 3.2.2 SNMP Management
Page 17 · click to enlarge
Page 17

3.2.1 Web Management

The PLANET Managed Media Converter provides a built-in browser interface. You can manage the Managed Media

Converter remotely by having a remote host with Web browser, such as Microsoft Internet Explorer, Netscape Navigator

or Mozilla Firefox.

Planet Technology GT-906B60 — 3.2.1 Web Management diagram (page 17)
Fig. 16 · 3.2.1 Web Management

The following shows how to startup the Web Management of the Managed Media Converter, please note the Managed

Media Converter is configured through an Ethernet connection, make sure the manager PC must be set on the same IP

subnet address, for example, the default IP address of the Managed Media Converter is 192.168.0.100 (the

factory-default IP address), then the manager PC should be set at 192.168.0.x (where x is a number between 1 and 254,

except 100), and the default subnet mask is 255.255.255.0.

Use Internet Explorer 5.0 or above Web browser, enter default IP address http://192.168.0.100

After entering the username and password (default user name and password is “admin”) in login screen then the Web

main screen appears.

3.2.2 SNMP Management

You can manage the Managed Media Converter across a LAN using an SNMP Network Management Station with a

graphical user interface.

This management method lets you monitor statistical counters and set Managed Media Converter parameters from the

remote Network Management Station.

Using this management method:

- The network must run the IP protocol.

- The Managed Media Converter must have an IP address.

Page 18 of the Planet Technology GT-906B60 user manual — 3.2.3 PLANET Smart Discovery Utility
Page 18 · click to enlarge
Page 18

3.2.3 PLANET Smart Discovery Utility

For easily list the Managed Media Converter in your Ethernet environment, the Planet Smart Discovery Utility from user’s

manual CD-ROM is an ideal solution.

The following install instructions guiding you for run the Planet Smart Discovery Utility.

1. Deposit the Planet Smart Discovery Utility in administrator PC.
2. Run this utility and the following screen appears.
Planet Technology GT-906B60 — 3.2.3 PLANET Smart Discovery Utility diagram (page 18)
Fig. 17 · 3.2.3 PLANET Smart Discovery Utility

Figure 3-1 Planet Smart Discovery Utility Screen

#Notice: If there are two LAN cards or above in the same administrator PC, choose different LAN card by

use the “Select Adapter” tool.

3. Press “Refresh” button for list current connected devices in the discovery list, the screen is shown as follow.
Planet Technology GT-906B60 — 3.2.3 PLANET Smart Discovery Utility diagram (page 18)
Fig. 18 · 3.2.3 PLANET Smart Discovery Utility

Figure 3-2 Planet Smart Discovery Utility Screen

Page 19 of the Planet Technology GT-906B60 user manual — # Notice:
Page 19 · click to enlarge
Page 19
3. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version,

Device IP Subnet address, also can assign new password, IP Subnet address and description for the devices.

4. After setup completed, press “Update Device” , “Update Multi” or “Update All” button to take affect. The meaning of

the 3 buttons above are shown as below:

Update Device: use current setting on one single device.

Update Multi: use current setting on choose multi-devices.

Update All: use current setting on whole devices in the list.

The same functions mentioned above also can be finding in “Option” tools bar.

5. To click the “Control Packet Force Broadcast” function, it can allow assign new setting value to the Managed Media

Converter under different IP subnet address.

6. Press “Connect to Device” button then the Web login screen appears in Figure 3-3 .
7. Press “Exit” button to shutdown the planet Smart Discovery Utility.

3.2.4 Login the Managed Media Converter

Before you start configure the Managed Media Converter, please note the Managed Media Converter is configured

through an Ethernet connection, make sure the manager PC must be set on same the IP subnet address. For example,

the default IP address of the Managed Media Converter is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 2 and 254), and the default subnet mask is 255.255.255.0. Use Internet

Explorer 6.0 or above Web browser. Enter IP address http://192.168.0.100 (the factory-default IP address) to access the Web interface.

When the following login screen appears, please enter the default username and password (default user name and

password is "admin"). Press Login to enter the main screen of Managed Media Converter. The login screen in Figure 3-3 appears.

Planet Technology GT-906B60 — 3.2.4 Login the Managed Media Converter diagram (page 19)
Fig. 19 · 3.2.4 Login the Managed Media Converter

Figure 3-3 Login Web Page screen

# Notice:

1. For security reason, please change and memorize the new password after this first setup.
2. Only accept command in lowercase letter under web interface.
Page 20 of the Planet Technology GT-906B60 user manual — 4.1 Main Menu
Page 20 · click to enlarge
Page 20

4. WEB MANAGEMENT

The GT-90X Managed Media Converter provide Web interface for management function configuration and make the

Managed Media Converter operate more effectively - They can be configured through the Web Browser. A network

administrator can manage and monitor the Managed Media Converter from the local LAN. This section indicates how to

configure the Managed Media Converter to enable its management function.

4.1 Main Menu

After a successful login, the main screen appears, the main screen displays the Managed Media Converter Welcome

page. The screen in Figure 4-1 appears.

Planet Technology GT-906B60 — 4.1 Main Menu diagram (page 20)
Fig. 20 · 4.1 Main Menu

Figure 4-1 Web Main screen

As listed at the left of the main screen, the configurable management functions are shown as below:

◆ System – Provide System configuration of Managed Media Converter. Explained in section 4.2.

◆ Port Management – Provide Port Management configuration of Managed Media Converter. Explained in

section 4.3.

◆ Converter Configuration – Provide Converter configuration of Managed Media Converter. Explained in

section 4.4.

◆ VLAN – Provide VLAN configuration of Managed Media Converter. Explained in section 4.5.

◆ Quality of Service – Provide Quality of Service (QoS) function of the Managed Media Converter. Explained in

section 4.6.

◆ OAM Setup – Provide OAM Setup function of the Managed Media Converter. Explained in section 4.7.

◆ Security – Provide Security function of the Managed Media Converter. Explained in section 4.8.

◆ Logout– Provide Logout function of the Managed Media Converter. Explained in section 4.9.

Page 21 of the Planet Technology GT-906B60 user manual — 4.2.1 System Information
Page 21 · click to enlarge
Page 21

4.2 System

4.2.1 System Information

The System Information Web page provides information for the current device. System Information Web page helps

network administrator to identify the firmware versions, IP Subnet Address and etc. The screen in Figure 4-2 appears and

Table 4-1 describes the System Information object of Managed Media Converter.

Planet Technology GT-906B60 — 4.2.1 System Information diagram (page 21)
Fig. 21 · 4.2.1 System Information

Figure 4-2 System Information Web page screen

The System Information Web page screen includes the following fields:

MAC Address Specifies the MAC address of Managed Media Converter.

Software Version The current software version running on the Managed Media Converter.

IP Address The current IP Address of Managed Media Converter, the default IP Address is 192.168.0.100.

Subnet Mask The current Subnet Mask of Managed Media Converter, the default Subnet Mask is 255.255.255.0.

Gateway The current gateway of Managed Media Converter, the factory default gateway is 192.168.0.254.

Description The current description of Managed Media Converter, the factory default description is GT-90X.

Table 4-1 Descriptions of the System Information Web Page Screen Objects

Page 22 of the Planet Technology GT-906B60 user manual — # Notice:
Page 22 · click to enlarge
Page 22

4.2.2 IP Configuration

The IP Configuration includes the DHCP Client, IP Address, Subnet Mask, Gateway and Description. The screen in Figure

4-3 appears and Table 4-2 describes the IP Configuration object of Managed Media Converter.

Planet Technology GT-906B60 — 4.2.2 IP Configuration diagram (page 22)
Fig. 22 · 4.2.2 IP Configuration

Figure 4-3 IP Configuration Web page screen

The IP Configuration Web page screen includes the following configurable data:

DHCP Client Allow disable or enable the DHCP Client function of the Managed Media Converter, the factory default mode is Disable.

IP Address Allow assigning a new IP address for the Managed Media Converter, the factory default IP address is 192.168.0.100.

Subnet Mask Allow assigning a new subnet mask for the Managed Media Converter, the factory default subnet mask is 255.255.255.0.

Gateway Allow assigning a new gateway for the Managed Media Converter, the factory default gateway is 192.168.0.254.

Description Allow to input a new description for the Managed Media Converter, up to maximum 32 characters allow.

Apply button Press “Apply” button for save current configuration of Managed Media Converter.

Table 4-2 Descriptions of the IP Configuration Web Page Screen Objects

# Notice:

After change the default IP subnet address, if you forget the IP subnet address. Please press the “Reset” button in the front panel of Managed Media Converter for 10 seconds, the current setting will be lost and the Managed Media Converter will restore to factory default mode.

Page 23 of the Planet Technology GT-906B60 user manual — 4.2.3 Password Setting
Page 23 · click to enlarge
Page 23

4.2.3 Password Setting

This function provides administrator to secure Web login. The screen in Figure 4-4 & 4-5 appears and Table 4-3 describes

the Password Setting object of Managed Media Converter.

Planet Technology GT-906B60 — 4.2.3 Password Setting diagram (page 23)
Fig. 23 · 4.2.3 Password Setting

Figure 4-4 Password Setting Web page screen

Planet Technology GT-906B60 — 4.2.3 Password Setting diagram (page 23)
Fig. 24 · 4.2.3 Password Setting

Figure 4-5 Password Setting Successful Web page screen

Page 24 of the Planet Technology GT-906B60 user manual — 4.2.4 Firmware Upgrade
Page 24 · click to enlarge
Page 24

The Password Setting Web page includes the following configurable data:

Login Name Displays the user name (admin).

Old Password Enter the old password is required before entering the new password.

New Password Specifies the new password. The password is not displayed. As it entered an “y” corresponding to each character is displayed in the field.

(The maximum length is 16 characters)

Confirm This confirms the new password. The password entered into this field must be exactly the same as the password entered in the Password field.

Apply button Press “Apply” button for save current configuration of Managed Media Converter.

Table 4-3 Descriptions of the Password Setting Web Page Screen Objects

4.2.4 Firmware Upgrade

This function provides Firmware Upgrade of the Managed Media Converter and the screen in Figure 4-6 appears.

Planet Technology GT-906B60 — 4.2.4 Firmware Upgrade diagram (page 24)
Fig. 25 · 4.2.4 Firmware Upgrade

Figure 4-6 Firmware Upgrade Web page screen

Page 25 of the Planet Technology GT-906B60 user manual — 4.2.4 Firmware Upgrade
Page 25 · click to enlarge
Page 25

Press “Browser” button to find the firmware location administrator PC, The screen in Figure 4-7 appears

Planet Technology GT-906B60 — 4.2.4 Firmware Upgrade diagram (page 25)
Fig. 26 · 4.2.4 Firmware Upgrade

Figure 4-7 Firmware Upgrade Web page screen

After find the firmware location from administrator PC, press “Upgrade” button to start the firmware upgrade process. The screen in Figure 4-8 & 4-9 appears.

Planet Technology GT-906B60 — 4.2.4 Firmware Upgrade diagram (page 25)
Fig. 27 · 4.2.4 Firmware Upgrade

Figure 4-8 Firmware Upgrade Web page screen

Page 26 of the Planet Technology GT-906B60 user manual — 4.2.4 Firmware Upgrade
Page 26 · click to enlarge
Page 26
Planet Technology GT-906B60 — 4.2.4 Firmware Upgrade diagram (page 26)
Fig. 28 · 4.2.4 Firmware Upgrade

Figure 4-9 Firmware Upgrade Web page screen

When firmware upgrade process is completed then the following screen appears, please click “here” to re-login the Managed Media Converter with latest firmware and the screen in Figure 4-10 & 4-11 appears.

Planet Technology GT-906B60 — 4.2.4 Firmware Upgrade diagram (page 26)
Fig. 29 · 4.2.4 Firmware Upgrade

Figure 4-10 Firmware Upgrade Web page screen

Page 27 of the Planet Technology GT-906B60 user manual — 4.2.4 Firmware Upgrade
Page 27 · click to enlarge
Page 27

Figure 4-11 Login Web page screen

Page 28 of the Planet Technology GT-906B60 user manual — 4.2.5 SNMP Management
Page 28 · click to enlarge
Page 28

4.2.5 SNMP Management

This function provides SNMP Management and SNMP Trap Receiver Configuration function of the Managed Media

Converter and the screen in Figure 4-12 & 4-13 appears and Table 4-4 & 4-5 describes the SNMP Management and

SNMP Trap Receiver object of Managed Media Converter.

Planet Technology GT-906B60 — 4.2.5 SNMP Management diagram (page 28)
Fig. 30 · 4.2.5 SNMP Management

Figure 4-12 SNMP Management Web page screen

The SNMP Management Web page includes the following configurable data:

SNMP Agent Allow disable or enable the SNMP Agent function, the default mode is “Disable”.

SNMP Read Community Allow input the characters for SNMP Read Community, up to maximum 16 characters allow.

SNMP Write Community Allow input the characters for SNMP Write Community, up to maximum 16 characters allow.

System Name Allow input the characters for System Name, up to maximum 16 characters allow.

System Location Allow input the characters for System Location, up to maximum 16 characters allow.

Contact Allow input the characters for Contact person, up to maximum 16 characters allow.

Apply button Press “Apply” button for save current configuration of Managed Media Converter.

Table 4-4 Descriptions of the SNMP Management Web Page Screen Objects

#Notice: The GT-90x supports SNMP v1 / v2c.

Page 29 of the Planet Technology GT-906B60 user manual — 4.2.5 SNMP Management
Page 29 · click to enlarge
Page 29
Planet Technology GT-906B60 — 4.2.5 SNMP Management diagram (page 29)
Fig. 31 · 4.2.5 SNMP Management

Figure 4-13 SNMP Trap Receiver Configuration Web page screen

The SNMP Trap Receiver Configuration Web page includes the following configurable data:

SNMP Trap Allow disable or enable the SNMP Trap function, the default mode is “Disable”.

SNMP Trap Destination Allow input the IP address of SNMP Trap Destination.

Cold Start When Managed Media Converter executes Cold Start operation, the administrator PC (SNMP Trap Destination) will receive a Cold Start Trap.

Warm Start When Managed Media Converter executes Warm Start operation, the administrator PC (SNMP Trap Destination) will receive a Warm Start Trap.

Login Fail When Web login fail situation appears on Managed Media Converter, the administrator PC (SNMP Trap Destination) will receive a Login Fail Trap.

Link Up When TP or Fiber port connection is build up, the administrator PC (SNMP Trap Destination) will receive a Link Up Trap.

Link Down When TP or Fiber port connection is Disconnect, the administrator PC (SNMP Trap Destination) will receive a Link Down Trap.

Apply button Press “Apply” button for save current configuration of Managed Media Converter.

Table 4-5 Descriptions of the SNMP Trap Receiver Configuration Web Page Screen Objects

Trap Event

Page 30 of the Planet Technology GT-906B60 user manual — 4.2.6 Factory Default
Page 30 · click to enlarge
Page 30

4.2.6 Factory Default

This function provides Factory Default function of the Managed Media Converter and the screen in Figure 4-14 & 4-15 &

4-16 appears.

Planet Technology GT-906B60 — 4.2.6 Factory Default diagram (page 30)
Fig. 32 · 4.2.6 Factory Default

Figure 4-14 Factory Default Web page screen

Planet Technology GT-906B60 — 4.2.6 Factory Default diagram (page 30)
Fig. 33 · 4.2.6 Factory Default

Figure 4-15 Factory Default Web page screen

Page 31 of the Planet Technology GT-906B60 user manual — 4.2.7 System Reboot
Page 31 · click to enlarge
Page 31

Figure 4-16 Login Web page screen 4.2.7 System Reboot

This function provides System Reboot function of the Managed Media Converter and the screen in Figure 4-17 & 4-18 &

4-19 appears.

Planet Technology GT-906B60 — 4.2.7 System Reboot diagram (page 31)
Fig. 34 · 4.2.7 System Reboot

Figure 4-17 System Reboot Web page screen

Page 32 of the Planet Technology GT-906B60 user manual — 4.2.7 System Reboot
Page 32 · click to enlarge
Page 32
Planet Technology GT-906B60 — 4.2.7 System Reboot diagram (page 32)
Fig. 35 · 4.2.7 System Reboot

Figure 4-18 System Reboot Web page screen

Figure 4-19 Login Web page screen

Page 33 of the Planet Technology GT-906B60 user manual — 4.3.1 Port Configuration
Page 33 · click to enlarge
Page 33

4.3 Port Management

4.3.1 Port Configuration

This function allows displaying TP / Fiber port status. The Link Status in the screen displays the current connection speed

and duplex mode; else this function will show red “Down” when the TP / Fiber port is disconnected. Press the “Refresh”

button to renew the screen. The screen in Figure 4-20 appears and Table 4-6 describes the Port Configuration object of

Managed Media Converter.

Planet Technology GT-906B60 — 4.3.1 Port Configuration diagram (page 33)
Fig. 36 · 4.3.1 Port Configuration

Figure 4-20 Port Configuration Web Page screen

The Port Configuration Web page includes the following configurable data:

Port Indicate the TP port and Fiber port.

Link Displays the current connection speed and duplex mode of TP or Fiber port.

Mode Allow configuring the TP or Fiber port speed and operation mode. Draw the menu bar to select the mode.

TP Port:

  • Auto Speed - Setup Auto negotiation.
  • 1000 Full - Force sets 1000Mbps Full-Duplex mode.
  • 100 Full - Force sets 100Mbps Full-Duplex mode.
  • 100 Half - Force sets 100Mbps Half-Duplex mode.
  • 10 Full - Force sets 10Mbps Full-Duplex mode.
  • 10 half - Force sets 10Mbps Half-Duplex mode.

Default mode: Auto Speed.

Fiber Port:

  • Auto Speed - Setup Auto negotiation.
  • 1000 Full - Force sets 1000Mbps Full-Duplex mode.

Default mode: Auto Speed.

Page 34 of the Planet Technology GT-906B60 user manual — 4.3 Port Management
Page 34 · click to enlarge
Page 34

Flow Control Allow Disable or Enable Flow Control of TP or Fiber port.

  • Enable – IEEE 802.3x Flow Control is enabled on Full-Duplex mode or Backpressure is enabled on Half-Duplex mode
  • Disable – No Flow Control or backpressure function on no matter Full-Duplex or Half-Duplex mode
Default modeDisable

Ingress Rate Limit The value of inbound traffic limitation in kilobit-per-second (kbps). The available options are :

  • No Limit
  • 512K
  • 1M
  • 2M
  • 4M
  • 8M
  • 10M
  • 50M
  • 100M
  • 500M
Default modeNo Limit

The Ingress Rate Limit configuration field as show in Figure 4-21.

Egress Shaping The value of outbound traffic limitation in kilobit-per-second (kbps). The available options are :

  • No Limit
  • 512K
  • 1M
  • 2M
  • 4M
  • 8M
  • 10M
  • 50M
  • 100M
  • 500M
Default modeNo Limit

The Egress Shaping configuration field as show in Figure 4-22.

Apply button Press this button for save current configuration of Managed Media Converter.

Refresh button Press “Refresh” button to refresh current status.

Table 4-6 Descriptions of the Port Configuration Web Page Screen Objects

Page 35 of the Planet Technology GT-906B60 user manual — 4.3 Port Management
Page 35 · click to enlarge
Page 35
Planet Technology GT-906B60 — 4.3 Port Management diagram (page 35)
Fig. 37 · 4.3 Port Management

Figure 4-21 Port Configuration-Ingress Rate Limit Web Page screen

Planet Technology GT-906B60 — 4.3 Port Management diagram (page 35)
Fig. 38 · 4.3 Port Management

Figure 4-22 Port Configuration-Egress Shaping Web Page screen

Page 36 of the Planet Technology GT-906B60 user manual — 4.3.2 Port Status
Page 36 · click to enlarge
Page 36

4.3.2 Port Status

This function allows displaying TP / Fiber port detail status, such as Link Status, Duplex Mode, Flow control, Speed and

Auto negotiation. Press the “Refresh” button to renew the screen, the screen in Figure 4-23 appears and Table 4-7

describes the Port Status object of Managed Media Converter.

Planet Technology GT-906B60 — 4.3.2 Port Status diagram (page 36)
Fig. 39 · 4.3.2 Port Status

Figure 4-23 Port Status Web Page screen

The Port Status Web page includes the following configurable data:

Port Indicate the TP port and Fiber port.

Link Status Displays the current link status of TP and Fiber port.

Duplex Mode Displays the current duplex mode of TP and Fiber port.

Flow Control Displays the current Flow Control status of TP and Fiber port.

Speed Displays the current speed mode of TP and Fiber port.

Auto Negotiation Displays the current Auto negotiation status of TP and Fiber port.

Refresh button Press “Refresh” button to refresh current status.

Table 4-7 Descriptions of the Port Status Web Page Screen Objects

Page 37 of the Planet Technology GT-906B60 user manual — 4.3.3 Port Statistics
Page 37 · click to enlarge
Page 37

4.3.3 Port Statistics

This function allows displaying TP / Fiber port detail Statistics, press the “Clear” button to clear current counter

information. Press the “Refresh” button to renew the screen, the screen in Figure 4-24 & 4-25 appears.

Planet Technology GT-906B60 — 4.3.3 Port Statistics diagram (page 37)
Fig. 40 · 4.3.3 Port Statistics

Figure 4-24 Port Statistics Web Page screen

Planet Technology GT-906B60 — 4.3.3 Port Statistics diagram (page 37)
Fig. 41 · 4.3.3 Port Statistics

Figure 4-25 Port Statistics Web Page screen

Page 38 of the Planet Technology GT-906B60 user manual — 4.4 Converter Configuration
Page 38 · click to enlarge
Page 38

4.4 Converter Configuration

This function provides useful setting for the Managed Media Converter, such as Maximum Packet length, Loop detection,

storm control and etc. The screen in Figure 4-26 appears and Table 4-8 describes the Converter Configuration object of

Managed Media Converter.

Planet Technology GT-906B60 — 4.4 Converter Configuration diagram (page 38)
Fig. 42 · 4.4 Converter Configuration

Figure 4-26 Converter Configuration Web Page screen

The Converter Configuration Web page includes the following configurable data:

Maximum Packet Length Provide maximum packet length setting for the Managed Media Converter, the available options are 1518 bytes, 2048 bytes and 16K bytes. Default mode is 16K bytes.

Loop Detection Provide Disable or enable the Loop detection function. Default mode is Disable.

Loop Status Displays the Loop Detection status.

Broadcast Storm Control Provide Disable or enable the Broadcast Storm Control function. Default mode is Disable.

Multicast Storm Control Provide Disable or enable the Multicast Storm Control function. Default mode is Disable.

Unicast Storm Control Provide Disable or enable the Unicast Storm Control function. Default mode is Disable.

Storm Trigger Counter Provide storm Trigger Counter setting and the available options are:

Default mode is 64 broadcast.

Show 4 more labels / short text on this page
64 broadcast · 32 broadcast · 16 broadcast · 8 broadcast
Page 39 of the Planet Technology GT-906B60 user manual — 4.5 VLAN
Page 39 · click to enlarge
Page 39

Storm Filter Timer Provide storm Filter Timer setting and the available options are:

Default mode is 800ms.

Apply button Press this button for save current configuration of Managed Media Converter.

Table 4-8 Descriptions of the Converter Configuration Web Page Screen Objects

4.5 VLAN

A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows you to isolate network traffic

so only members of the VLAN receive traffic from the same VLAN members. Basically, creating a VLAN from a converter

is logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network

devices are still plug into the same switch physically.

The Managed Media Converter supports IEEE 802.1Q (tagged-based) VLAN setting in web management page. In the

default configuration, VLAN support is “No VLAN”.

IEEE 802.1Q VLANs

IEEE 802.1Q (tagged) VLAN are implemented on the Managed Media Converter. 802.1Q VLAN require tagging, which

enables them to span the entire network (assuming all devices on the network are IEEE 802.1Q-compliant).

VLAN allow a network to be segmented in order to reduce the size of broadcast domains. All packets entering a VLAN will

only be forwarded to the stations (over IEEE 802.1Q enabled switches) that are members of that VLAN, and this includes

broadcast, multicast and unicast packets from unknown sources.

VLAN can also provide a level of security to your network. IEEE 802.1Q VLAN will only deliver packets between stations

that are members of the VLAN. Any port can be configured as either tagging or untagging. The untagging feature of IEEE

802.1Q VLAN allows VLAN to work with legacy switches that don't recognize VLAN tags in packet headers. The tagging

feature allows VLAN to span multiple 802.1Q-compliant switches through a single physical connection and allows

Spanning Tree to be enabled on all ports and work normally.

Any port can be configured as either tagging or untagging. The untagging feature of IEEE 802.1Q VLAN allows VLAN to

work with legacy switches that don’t recognize VLAN tags in packet headers. The tagging feature allows VLAN to span

multiple 802.1Q-compliant switches through a single physical connection and allows Spanning Tree to be enabled on all

ports and work normally.

Some relevant terms:

Tag - The act of putting 802.1Q VLAN information into the header of a packet.

Untag - The act of stripping 802.1Q VLAN information out of the packet header.

802.1Q VLAN Tags

The figure below shows the 802.1Q VLAN tag. There are four additional octets inserted after the source MAC address.

Their presence is indicated by a value of 0x8100 in the Ether Type field. When a packet's Ether Type field is equal to

0x8100, the packet carries the IEEE 802.1Q/802.1p tag. The tag is contained in the following two octets and consists of 3

bits of user priority, 1 bit of Canonical Format Identifier (CFI - used for encapsulating Token Ring packets so they can be

carried across Ethernet backbones), and 12 bits of VLAN ID (VID). The 3 bits of user priority are used by 802.1p. The VID

is the VLAN identifier and is used by the 802.1Q standard. Because the VID is 12 bits long, 4094 unique VLAN can be

identified.

The tag is inserted into the packet header making the entire packet longer by 4 octets. All of the information originally

contained in the packet is retained.

Show 4 more labels / short text on this page
800ms · 400ms · 200ms · 100ms
Page 40 of the Planet Technology GT-906B60 user manual — 4.5 VLAN
Page 40 · click to enlarge
Page 40

802.1Q Tag

User Priority CFI VLAN ID (VID)

3 bits 1 bits 12 bits

TPID (Tag Protocol Identifier) TCI (Tag Control Information)

2 bytes 2 bytes

Source Address VLAN TAG Ethernet

6 bytes 6 bytes 4 bytes 2 bytes 46-1517 bytes 4 bytes

The Ether Type and VLAN ID are inserted after the MAC source address, but before the original Ether Type/Length or

Logical Link Control. Because the packet is now a bit longer than it was originally, the Cyclic Redundancy Check (CRC)

must be recalculated.

Adding an IEEE802.1Q Tag

Dest. Addr. Src. Addr. Length/E. type Data Old CRC

Dest. Addr. Src. Addr. E. type Tag Length/E. type Data New CRC

Priority CFI VLAN ID

Packets that are tagged (are carrying the 802.1Q VID information) can be transmitted from one 802.1Q compliant network

device to another with the VLAN information intact. This allows 802.1Q VLAN to span network devices (and indeed, the

entire network – if all network devices are 802.1Q compliant).

Every physical port on a switch has a PVID. 802.1Q ports are also assigned a PVID, for use within the switch. If no VLAN

are defined on the switch, all ports are then assigned to a default VLAN with a PVID equal to 1. Untagged packets are

assigned the PVID of the port on which they were received. Forwarding decisions are based upon this PVID, in so far as

VLAN are concerned. Tagged packets are forwarded according to the VID contained within the tag. Tagged packets are

also assigned a PVID, but the PVID is not used to make packet forwarding decisions, the VID is.

Tag-aware switches must keep a table to relate PVID within the switch to VID on the network. The switch will compare the

VID of a packet to be transmitted to the VID of the port that is to transmit the packet. If the two VID are different the switch

will drop the packet. Because of the existence of the PVID for untagged packets and the VID for tagged packets,

tag-aware and tag-unaware network devices can coexist on the same network.

A switch port can have only one PVID, but can have as many VID as the switch has memory in its VLAN table to store

them.

Because some devices on a network may be tag-unaware, a decision must be made at each port on a tag-aware device

before packets are transmitted – should the packet to be transmitted have a tag or not? If the transmitting port is

connected to a tag-unaware device, the packet should be untagged. If the transmitting port is connected to a tag-aware

device, the packet should be tagged.

Show 6 more labels / short text on this page
Preamble Destination · Type Data FCS · Address · Original Ethernet · New Tagged Packet · Port VLAN ID
Page 41 of the Planet Technology GT-906B60 user manual — 4.5.1 VLAN Group
Page 41 · click to enlarge
Page 41

The Managed Media Converter initially configures one VLAN, VID = 1, called "default." The factory default setting

assigns all ports on the Managed Media Converter to the "default". As new VLAN are configured in Port-based mode,

their respective member ports are removed from the "default."

4.5.1 VLAN Group

This function allows disable or enable the IEEE 802.1Q VLAN operation mode. Press the “Apply” button to save the

current configuration of Managed Media Converter. The screen in Figure 4-27 & 4-28 appears and Table 4-9 describes the

VLAN Group object of Managed Media Converter.

Planet Technology GT-906B60 — 4.5.1 VLAN Group diagram (page 41)
Fig. 43 · 4.5.1 VLAN Group

Figure 4-27 VLAN Group Web Page screen

Default VLANs

Page 42 of the Planet Technology GT-906B60 user manual — 4.5.1 VLAN Group
Page 42 · click to enlarge
Page 42
Planet Technology GT-906B60 — 4.5.1 VLAN Group diagram (page 42)
Fig. 44 · 4.5.1 VLAN Group

Figure 4-28 VLAN Group Web Page screen

The VLAN Group Web page includes the following configurable data:

VLAN Mode Provide Disable or enable the IEEE 802.1Q VLAN operation mode. Default mode is Disable.

Management VLAN Group Provide define the Management VLAN group. Default mode is VLAN1.

VLAN Group Indicate the VLAN Group from 1 to 16.

VID Provide define the VLAN Group ID and the available options are 1 to 4094.

TP Provide assign TP port into VLAN Groups.

Fiber Provide assign Fiber port into VLAN Groups.

Apply button Press this button for save current configuration of Managed Media Converter.

Table 4-9 Descriptions of the VLAN Group Web Page Screen Objects

#Notice: When change the Management VLAN Group setting, please assure the TP or fiber port that

connect to administrator PC is in the same VLAN Group, otherwise, for further managed is impossible. The only solution is press the reset button 10 seconds for system reset to default mode.

Member

Page 43 of the Planet Technology GT-906B60 user manual — 4.5.2 VLAN Per Port Setting
Page 43 · click to enlarge
Page 43

4.5.2 VLAN Per Port Setting

This function provides IEEE 802.1Q VLAN per port setting for TP and Fiber port of Managed Media Converter. Press the

“Apply” button to save the current configuration of Managed Media Converter. The screen in Figure 4-29 appears and

Table 4-10 describes the VLAN Per Port Setting object of Managed Media Converter.

Planet Technology GT-906B60 — 4.5.2 VLAN Per Port Setting diagram (page 43)
Fig. 45 · 4.5.2 VLAN Per Port Setting

Figure 4-29 VLAN Per Port Setting Web Page screen

The VLAN Per Port Setting Web page includes the following configurable data:

Port Indicate the TP port and Fiber port.

Egress Link Type Provide Egress Link Type options for TP port and Fiber port, the available options are:

Default mode is UnTag.

PVID Provide PVID assign for TP port and Fiber port, the available options are 1 to 4094. Default mode is 1 to 16.

Accept Frame Type Provide define the Accept Frame Type and the available options are

Default mode is All.

Ingress Filter Provide disable or enable the Ingress Filter function. Default mode is Enable.

Apply button Press this button for save current configuration of Managed Media Converter.

Table 4-10 Descriptions of the VLAN Per Port Setting Web Page Screen Objects

Show 5 more labels / short text on this page
UnTag · Tag · ByPass · All · Tagged Only
Page 44 of the Planet Technology GT-906B60 user manual — 4.5.3 Q-in-Q VLAN Setting
Page 44 · click to enlarge
Page 44

4.5.3 Q-in-Q VLAN Setting

When enable Q-in-Q function, Managed Media Converter can insert or remove 4-bytes Q-in-Q tag in the received 802.3

frames after SA. User can define Q-in-Q tag value freely. And in default condition, Q-in-Q tag format is same as VLAN tag.

In normal application, enable two port’s Q-in-Q function. UTP Port set to insert QinQ tag and Fiber port set to remove

Q-in-Q Tag. For aggregation layer switch, it will check Q-in-Q tag only, not care about the VLAN tag from the corridor layer

switch. Q-in-Q Tag ether type can be set same as VLAN tag ether type or other values.

This function provides IEEE 802.1Q Q-in-Q VLAN setting of Managed Media Converter. Press the “Apply” button to save

the current configuration of Managed Media Converter. The screen in Figure 4-30 appears and Table 4-11 describes the

Q-in-Q VLAN setting object of Managed Media Converter.

Planet Technology GT-906B60 — 4.5.3 Q-in-Q VLAN Setting diagram (page 44)
Fig. 46 · 4.5.3 Q-in-Q VLAN Setting

Figure 4-30 Q-in-Q VLAN setting Web Page screen

The Q-in-Q VLAN setting Web page includes the following configurable data:

Q-in-Q Enable Provide disable or enable the Q-in-Q VLAN function. Default mode is Disable.

Q-in-Q direction Provide two directions for Q-in-Q function, the available options are:

UTP is customer port, Fiber is main port

Fiber is customer port, UTP is main port

Default mode is UTP is customer port, Fiber is main port.

Out Layer VLAN Tag EtherType (HEX)

Allow defined the Out Layer VLAN Tag EtherType and default mode is 0x8100.

Out Layer VLAN VID (DEC) Allow defined the Out Layer VLAN VID and default mode is 1.

Apply button Press this button for save current configuration of Managed Media Converter.

Table 4-11 Descriptions of the Q-in-Q VLAN setting Web Page Screen Objects

Page 45 of the Planet Technology GT-906B60 user manual — 4.6 Quality of Service
Page 45 · click to enlarge
Page 45

4.6 Quality of Service

Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traffic.

QoS enables you to assign various grades of network service to different types of traffic, such as multi-media, video,

protocol-specific, time critical, and file-backup traffic.

QoS reduces bandwidth limitations, delay, loss, and jitter. It also provides increased reliability for delivery of your data and

allows you to prioritize certain applications across your network. You can define exactly how you want the switch to treat

selected applications and types of traffic.

You can use QoS on your system to:

。 Control a wide variety of network traffic by:

。 Classifying traffic based on packet attributes.

。 Assigning priorities to traffic (for example, to set higher priorities to time-critical or business-critical applications).

。 Applying security policy through traffic filtering.

。 Provide predictable throughput for multimedia applications such as video conferencing or voice over IP by

minimizing delay and jitter.

。 Improve performance for specific types of traffic and preserve performance as the amount of traffic grows.

。 Reduce the need to constantly add bandwidth to the network.

。 Manage network congestion.

This function provides Quality of Service setting of Managed Media Converter. Press the “Apply” button to save the

current configuration of Managed Media Converter. The screen in Figure 4-31 appears and Table 4-12 describes the

Quality of Service object of Managed Media Converter.

Planet Technology GT-906B60 — 4.6 Quality of Service diagram (page 45)
Fig. 47 · 4.6 Quality of Service

Figure 4-31 Quality of Service Web Page screen

Page 46 of the Planet Technology GT-906B60 user manual — 4.6 Quality of Service
Page 46 · click to enlarge
Page 46

The Quality of Service Web page includes the following configurable data:

Qos Mode Provide 4 different QoS mode for operation, the available options are:

802.1p Tag Priority

The 802.1p Tag Priority field as show in Figure 4-32.

The IP Address Priority field as show in Figure 4-33.

The IP DSCP Priority field as show in Figure 4-34.

Default mode is Disable.

Scheduling Provide two scheduling method for Quality of Service, the available options are:

Weighted Round Robin (16:8:4:1)

Default mode is Strict Priority.

Apply button Press this button for save current configuration of Managed Media Converter.

Table 4-12 Descriptions of the Quality of Service Web Page Screen Objects

Planet Technology GT-906B60 — 4.6 Quality of Service diagram (page 46)
Fig. 48 · 4.6 Quality of Service

Figure 4-32 802.1p Tag Priority Web Page screen

Show 4 more labels / short text on this page
Disable · IP Address Priority · IP DSCP Priority · Strict Priority
Page 47 of the Planet Technology GT-906B60 user manual — 4.6 Quality of Service
Page 47 · click to enlarge
Page 47
Planet Technology GT-906B60 — 4.6 Quality of Service diagram (page 47)
Fig. 49 · 4.6 Quality of Service

Figure 4-33 IP Address Priority Web Page screen

Planet Technology GT-906B60 — 4.6 Quality of Service diagram (page 47)
Fig. 50 · 4.6 Quality of Service

Figure 4-34 IP DSCP Priority Web Page screen

Page 48 of the Planet Technology GT-906B60 user manual — 4.7.1 Local TS-1000 OAM Setup
Page 48 · click to enlarge
Page 48

4.7 OAM Setup

4.7.1 Local TS-1000 OAM Setup

This function provides Local TS-1000 OAM Setup of Managed Media Converter. Press the “Apply” button to save the

current configuration of Managed Media Converter. The screen in Figure 4-35 appears and Table 4-13 describes the

Local TS-1000 OAM Setup object of Managed Media Converter.

Planet Technology GT-906B60 — 4.7.1 Local TS-1000 OAM Setup diagram (page 48)
Fig. 51 · 4.7.1 Local TS-1000 OAM Setup

Figure 4-35 Local TS-1000 OAM Setup Web Page screen

The Local TS-1000 OAM Setup Web page includes the following configurable data:

TS-1000 OAM State Provide disable or enable the TS-1000 OAM operation mode. Default mode is Disable.

TS-1000 Mode Provide two TS-1000 modes for operation, the available options are:

Default mode is Terminal.

Link Transparent Provide disable or enable the Link Transparent function. Default mode is Disable.

Link Transparent Result Display the link transparent result.

Apply button Press this button for save current configuration of Managed Media Converter.

Table 4-13 Descriptions of the Local TS-1000 OAM Setup Web Page Screen Objects

Terminal · Center

Page 49 of the Planet Technology GT-906B60 user manual — 4.7.2 Remote TS-1000 OAM Setup
Page 49 · click to enlarge
Page 49

4.7.2 Remote TS-1000 OAM Setup

The Remote TS-1000 OAM Setup is an advanced remote device monitor feature that allows you to Remote monitor and

automatic notify status indication.

1. User instructs center Media Converter to issue a status notification request frame defined in TS-1000 to get status of

terminal Media Converter.

2. Terminal Media Converter receives the status notification request frame and sends out status response frame, which

carries its current status.

1. Terminal Media Converter notifies the center Media Converter autonomously with a status notification indication, if any

change occurs in the status monitored internally by the terminal Media Converter.

2. Center Media Converter if support Option A, notifies the terminal Media Converter autonomously with a status

notification indication, if any change occurs in the status monitored internally by the center Media Converter.

This function provides Remote TS-1000 OAM Setup of Managed Media Converter. Press the “Apply” button to save the

current configuration of Managed Media Converter. The screen in Figure 4-36 & 4-37 appears.

Planet Technology GT-906B60 — 4.7.2 Remote TS-1000 OAM Setup diagram (page 49)
Fig. 52 · 4.7.2 Remote TS-1000 OAM Setup

Figure 4-36 GT-80x Remote TS-1000 OAM Setup Web Page screen

Remote monitor · Autonomous notification

Page 50 of the Planet Technology GT-906B60 user manual — 4.7.2 Remote TS-1000 OAM Setup
Page 50 · click to enlarge
Page 50
Planet Technology GT-906B60 — 4.7.2 Remote TS-1000 OAM Setup diagram (page 50)
Fig. 53 · 4.7.2 Remote TS-1000 OAM Setup

Figure 4-37 GT-90x Remote TS-1000 OAM Setup Web Page screen

#Notice: Please use the PLANET GT-80x and GT-90x as the Remote device.

Page 51 of the Planet Technology GT-906B60 user manual — 4.7.3 TS-1000 Loop Back Test
Page 51 · click to enlarge
Page 51

4.7.3 TS-1000 Loop Back Test

The TS-1000 Loop Back Test allows manual run this loop back test to check the interconnection between two Media

Converter devices. To assure the Remote TS-1000 OAM function can work correctly.

Planet Technology GT-906B60 — 4.7.3 TS-1000 Loop Back Test diagram (page 51)
Fig. 54 · 4.7.3 TS-1000 Loop Back Test

In-band and out-band Loop back

1. Instruct center Media Converter to issue an OAM frame to request a loop back test. Terminal return start response

OAM frame to center Media Converter.

2. Terminal Media Converter runs at loop back mode.
3. Central Media Converter send test frame and terminal Media Converter loop back the frames. Test frame can be

generated from central Media Converter’s UTP port (Out-Band) or from central Media Converter (In-Band)

automatically.

4. Center Media Converter check the loop back test result after sending all test frames
5. Instruct the central Media Converter to end loop back test.

This function provides TS-1000 Loop Back Test of Managed Media Converter. Press the “Apply” button to run Loop Back

Test and see the TS-1000 Loop Back Test Result of Managed Media Converter, also press the “Refresh” button to renew the Web screen. The screen in Figure 4-38 appears and Table 4-14 describes the TS-1000 Loop Back Test object of

Managed Media Converter.

Page 52 of the Planet Technology GT-906B60 user manual — 4.7.3 TS-1000 Loop Back Test
Page 52 · click to enlarge
Page 52
Planet Technology GT-906B60 — 4.7.3 TS-1000 Loop Back Test diagram (page 52)
Fig. 55 · 4.7.3 TS-1000 Loop Back Test

Figure 4-38 Remote TS-1000 Loop Back Test Web Page screen

The TS-1000 Loop Back Test Web page includes the following configurable data:

TS-1000 Loop Back Test

Send Packet Number Allow input the number for packet send and the available options is 1 to 255. Default is 16.

Apply button Press this button for save current configuration of Managed Media Converter.

Refresh button Press “Refresh” button to refresh current status.

TS-1000 Loop Back Test Result

Result Display the TS-1000 Loop Back Test Result. Fail or Pass.

Result counter Display the value of Counter Result.

Table 4-14 Descriptions of the TS-1000 Loop Back Test Web Page Screen Objects

#Notice: Please use the PLANET GT-80x and GT-90x as the Remote device.

Page 53 of the Planet Technology GT-906B60 user manual — 4.7.4 802.3ah Setup
Page 53 · click to enlarge
Page 53

4.7.4 802.3ah Setup

When enable 802.3ah OAM function, all 802.3ah OAMPDU packets will trap to embedded CPU.

Software will implement auto discovery procedure. With hardware support, software controls the 802.3ah remote loop

back procedure. Hardware can also detect dying gasp even and interrupt CPU to send dying gasp even notification

OAMPDU. All other functions defined by 802.3ah are implemented using embedded CPU.

When remote device is in loop back mode, hardware can support change looped test frame’s DA, SA or both as user

defined. Hardware can also set to don't change looped test frame.

This function provides 802.3ah Setup of Managed Media Converter. Press the “Apply” button to save the current

configuration of Managed Media Converter. The screen in Figure 4-39 appears and Table 4-15 describes the 802.3ah

Setup object of Managed Media Converter.

Planet Technology GT-906B60 — 4.7.4 802.3ah Setup diagram (page 53)
Fig. 56 · 4.7.4 802.3ah Setup

Figure 4-39 802.3ah Setup Web Page screen

The 802.3ah Setup Web page includes the following configurable data:

802.3ah OAM State Provide disable or enable the 802.3ah OAM State function. Default mode is Enable.

802.3ah OAM Mode Allow to choose “Active” or “Passive” for 802.3ah OAM Mode. Default mode is Passive.

Loopback Reply Provide disable or enable the Loopback Reply function. Default mode is Enable.

Remote OAM Configure Provide disable or enable the Remote OAM Configure function. Default mode is Enable.

Remote OAM Configuration Result

Display the Remote OAM Configuration Result.

Apply button Press this button for save current configuration of Managed Media Converter.

Table 4-15 Descriptions of the 802.3ah Setup Web Page Screen Objects

Page 54 of the Planet Technology GT-906B60 user manual — 4.7.5 802.3ah Loop Back Test
Page 54 · click to enlarge
Page 54

#Notice: 1. The 802.3ah function must work with manageable device that supports 802.3ah function.

2. Please use the PLANET GT-90x as the Remote device.

4.7.5 802.3ah Loop Back Test

The 802.3ah Loop Back Test allows manual run this loop back test to check the interconnection between two Media

Converter devices. To assure the Remote 802.3ah function can work correctly.

This function provides 802.3ah Loop Back Test of Managed Media Converter. Press the “Apply” button to run 802.3ah

Loop Back Test and see the 802.3ah Loop Back Test Result of Managed Media Converter, also press the “Refresh”

button to renew the Web screen. The screen in Figure 4-40 appears and Table 4-16 describes the 802.3ah Loop Back

Test object of Managed Media Converter.

Page 55 of the Planet Technology GT-906B60 user manual — 4.7.5 802.3ah Loop Back Test
Page 55 · click to enlarge
Page 55
Planet Technology GT-906B60 — 4.7.5 802.3ah Loop Back Test diagram (page 55)
Fig. 57 · 4.7.5 802.3ah Loop Back Test

Figure 4-40 802.3ah Loop Back Test Web Page screen

The 802.3ah Loop Back Test Web page includes the following configurable data:

802.3ah Loop Back Test

Send Packet Number Allow input the number for packet send and the available options is 1 to 255. Default is 16.

Packet Length (Not include CRC)

Allow input the number for Packet Length and the available options is 60 to 1514. Default is 60.

Apply button Press this button for save current configuration of Managed Media Converter.

Refresh button Press “Refresh” button to refresh current status.

802.3ah Loop Back Test Result

Result Display the 802.3ah Loop Back Test Result. Fail or Pass.

Table 4-16 Descriptions of the 802.3ah Loop Back Test Web Page Screen Objects

#Notice: 1. The 802.3ah function must work with manageable device that supports 802.3ah function.

2. Please use the PLANET GT-90x as the Remote device.
Page 56 of the Planet Technology GT-906B60 user manual — 4.8 Security
Page 56 · click to enlarge
Page 56

4.8 Security

This function provides TCP / UDP Filter setting of Managed Media Converter. Press the “Apply” button to save the

current configuration of Managed Media Converter. The screen in Figure 4-41 appears and Table 4-17 describes the TCP

/ UDP Filter setting object of Managed Media Converter.

Planet Technology GT-906B60 — 4.8 Security diagram (page 56)
Fig. 58 · 4.8 Security

Figure 4-41 Security setting Web Page screen

The Quality of Service Web page includes the following configurable data:

Group ID Provide input the group ID for TCP / UDP Filter and the available range is 1 to 16.

Action Provide “Deny” or “Permit” options and default mode is Permit.

Egress Port Provide choose “TP” or “Fiber” as Egress Port. Default mode is TP.

Packet Type Provide IPv4 and Non-IPv4 protocol for further setting.

L4 Protocol Provide IPv4 and Non-IPv4 protocol for further setting.

IPv4TCP Any / FTP (21) / HTTP (80), UDP Any / TFTP (69)
Non-IPv4Any / ARP (0x0806) / IPX (0X8137)

Current List Display current TCP / UDP Filter Groups.

Add button Press this button for add new TCP / UDP Filter group into current list.

Del button Press this button for delete existence TCP / UDP Filter group from current list.

Table 4-17 Descriptions of the Security setting Web Page Screen Objects

Page 57 of the Planet Technology GT-906B60 user manual — 4.9 Logout
Page 57 · click to enlarge
Page 57

4.9 Logout

This function provides Logout function of Managed Media Converter, when the “Are you sure to logout” pop window

appears; press the “OK” button to logout Web page of Managed Media Converter. The screen in Figure 4-42 & 4-43 appears.

Planet Technology GT-906B60 — 4.9 Logout diagram (page 57)
Fig. 59 · 4.9 Logout

Figure 4-42 Logout Web Page screen

Figure 4-43 Login Web Page screen

Page 58 of the Planet Technology GT-906B60 user manual — Performance is bad
Page 58 · click to enlarge
Page 58

5. TROUBLESHOOTING

This chapter contains information to help you solve problems. If the media converter is not functioning properly, make sure

the media converter was set up according to instructions in this manual.

The Link LED is not lit

Solution:

1. Check the cable connection and remove duplex mode of the Managed Media Converter.
2. Check the port configuration of the link partner; make sure the two side devices with the same link

configuration.

Performance is bad

Solution:

Check the full duplex status of the device. If the device is set to full duplex and the partner is set to half duplex, then

the performance will be poor.

10/100/1000Base-T port link LED is lit, but the traffic is irregular Solution:

Check that the attached device is not set to dedicate full duplex. Some devices use a physical or software switch to

change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting.

Why the device doesn’t connect to the network

Solution:

Check the LNK/ACT LED on the Managed Media Converter .Try another port on the connected device. Make sure the

cable is installed properly Make sure the cable is the right type Turn off the power. After a while, turn on power again.

How to deal forgotten password situation of device?

Solution:

The Managed Media Converter is implemented with “Reset” button, press the button at the front panel about 10

seconds. After the device be rebooted. Login the Web Management page with default user name and password

(admin).

Planet Technology GT-906B60 — Performance is bad diagram (page 58)
Fig. 60 · Performance is bad

Hardware Reset

Page 59 of the Planet Technology GT-906B60 user manual — A.2 RJ-45 cable pin assignment
Page 59 · click to enlarge
Page 59

APPENDIX A NETWORKING CONNECTION

A.1 Device‘s RJ-45 Pin Assignments

  • 1000Mbps, 1000Base T
Planet Technology GT-906B60 — A.1 Device‘s RJ-45 Pin Assignments diagram (page 59)
Fig. 61 · A.1 Device‘s RJ-45 Pin Assignments
Planet Technology GT-906B60 — A.1 Device‘s RJ-45 Pin Assignments diagram (page 59)
Fig. 62 · A.1 Device‘s RJ-45 Pin Assignments

A.2 RJ-45 cable pin assignment

2 1 3 6

2 1 3 6

1 2 3 6

The standard RJ-45 receptacle/connector

10/100Mbps, 10/100Base-TX

Page 60 of the Planet Technology GT-906B60 user manual — Standard Fiber Diameter (micron) Modal Bandwidth
Page 60 · click to enlarge
Page 60

There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection:

Planet Technology GT-906B60 — A.3 Fiber Optical Cable Connection Parameter diagram (page 60)
Fig. 63 · A.3 Fiber Optical Cable Connection Parameter
Figure A-1Straight-Through and Crossover Cable

Please make sure your connected cables are with same pin assignment and color as above picture before deploying the cables into your network.

A.3 Fiber Optical Cable Connection Parameter

The wiring details are as below:

  • Fiber Optical patch Cables:

Standard Fiber Diameter (micron) Modal Bandwidth

Max. Distance

(MHz * km)

(meters)

1000Base-SX Multi-mode 62.5

Multi-mode 62.5

Single-mode 9 N/A 5000*

1000Base-LX

Page 61 of the Planet Technology GT-906B60 user manual — 2080-AA3450-002
Page 61 · click to enlarge
Page 61

A.4 Power Information

The power jack of Managed Media Converter is with 2.5mm in the central post and required +5VDC power input. It will

conform to the bundled AC-DC adapter and Planet’s Media Chassis. Should you have the problem to make the power

connection, please contact your local sales representative.

Please keep the AC-DC adapter as spare parts when your Managed Media Converter is installed to a Media Chassis.

2.5mm

DC Receptacle 2.5mm

+5V for each slot

DC receptacle is 2.5mm wide that conforms to and matches the Media Converter 2.5mm DC jack's central post. Do not install any improper unit, model of the Media Converter

A.5 Available Modules

The following list the available Modules for GT-905A

MGB-GT SFP-Port 1000Base-T mini-GBIC module

MGB-SX SFP-Port 1000Base-SX mini-GBIC module

MGB-LX SFP-Port 1000Base-LX mini-GBIC module

MGB-L30 SFP-Port 1000Base-LX mini-GBIC module -30KM

MGB-L50 SFP-Port 1000Base-LX mini-GBIC module -50KM

MGB-L70 SFP-Port 1000Base-LX mini-GBIC module -70KM

MGB-L120 SFP-Port 1000Base-LX mini-GBIC module -120KM

MGB-LA10 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1310nm), SM,10km

MGB-LB10 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1550nm), SM,10km

MGB-LA20 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1310nm), SM,20km

MGB-LB20 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1550nm), SM,20km

MGB-LA40 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1310nm), SM,40km

MGB-LB40 SFP-Port 1000Base-LX mini-GBIC module- LC WDM(TX:1550nm), SM,40km

2080-AA3450-002

Page 62 of the Planet Technology GT-906B60 user manual — PLANET TECHNOLOGY CORPORATION
Page 62 · click to enlarge
Page 62
Planet Technology GT-906B60 — A.4 Power Information diagram (page 62)
Fig. 64 · A.4 Power Information

EC Declaration of Conformity For the following equipment: *Type of Product : 10/100/1000Base-T to 1000Base-SX/LX Managed Gigabit Converter *Model Number : GT-90xynn

x: can be 2,5,6; y: can be blank or S, A, B; nn: can be blank or 15,60 for different distance * Produced by: Manufacturer‘s Name : Planet Technology Corp. Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Electromagnetic Compatibility Directive on (89/336/EEC). For the evaluation regarding the EMC, the following standards were applied:

Emission EN 55022 (1994 + A1:1995 + A2:1997) Harmonic EN 61000-3-2 (2000) Flicker EN 61000-3-3 (1995 + A1:2001) Immunity EN 55024 (1998) ESD IEC 61000-4-2 (2001) RS IEC 61000-4-3 (1995) EFT/ Burst IEC 61000-4-4 (1995) Surge IEC 61000-4-5 (1995) CS IEC 61000-4-6 (1996) Magnetic Field IEC 61000-4-8 (1993) Voltage Disp IEC 61000-4-11 (1994)

Responsible for marking this declaration if the:

⌧ Manufacturer † Authorized representative established within the EU

Authorized representative established within the EU (if applicable):

Company Name: Planet Technology Corp.

Company Address: 11F, No.96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C

Person responsible for making this declaration

Name, Surname Kent Kang

Position / TitleProduct Manager

Taiwan 27, Oct., 2008 Place Date Legal Signature

PLANET TECHNOLOGY CORPORATION

e-mail: sales@planet.com.tw http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Planet Technology GT-906B60

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Planet Technology GT-906B60

Be the first to ask — other owners or our team will answer.

Original document

Planet Technology GT-906B60 manual PDF

62 pages·5.5 MB·TV Converter Box·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…