EN
Planet Technology logo
Official user manual

Planet Technology FSD-1601SC

23 pages·532 KB·Switch·PDF·ENDEFRITNLJA
Planet Technology FSD-1601SC
Table of Contents 25 sections General Introduction · 1.1 Checklist · 1.2 Introduction · 1.3 Features · … ShowHide
Page 1 of the Planet Technology FSD-1601SC user manual
Page 1 · click to enlarge
Page 1
Page 1 of the Planet Technology FSD-1601SC user manual
Page 2 of the Planet Technology FSD-1601SC user manual — Revision
Page 2 · click to enlarge
Page 2

Trademarks

Copyright PLANET Technology Corp. 2004

PLANET is a registered trademark of PLANET Technology Corp.

All other trademarks belong to their respective owners. Contents in this docu ment are subject to revision without prior notice.

FCC Class A Appliance

This equipment generates and uses radio frequency energy. If it is not installed and used properly in strict accordance with the manufacturer‘s instructions, it may cause interference to radio and television reception. It has been type- tested and found to comply the specifications in sub-part J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such inter ference in a residential installation. There is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception which can be determined by turning the equip ment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient the receiving antenna

Relocate the computing device with respect to the receiver

Move the computer away from the deceiver

Plug the computer into a different outlet so that compute and receiver are on different electrical circuits.

If necessary the user should consult the dealer or an experienced radio or television technician for additional suggestions.

CE Mark Warning

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Revision

The information in this manual is subject to change without notice.

User's manual for PLANET 8/16-port 10/100Mbps Fast Ethernet Switch

ModelFSD-800/1600/801/1601SC & ST
Rev4.0 (July. 2004)

Part No. 2010-000004-003

Page 4 of the Planet Technology FSD-1601SC user manual — 1.2 Introduction
Page 4 · click to enlarge
Page 4

Chapter 1 General Introduction

1.1 Checklist

Check the contents of your package for following parts:

  • The Fast Ethernet Switch
  • User’s Manual
  • Power Cord

If any of these pieces are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair.

1.2 Introduction

The 8/16-port 10/100Mbps Ethernet Switch is designed to allow simultaneous transmission of multiple packets via an internal high-speed data channel. This means that it can partition a network more efficiently than bridges or routers in most environments.

This Switch is a highly reliable network switch and is the ideal device for bridging Ethernet to Fast Ethernet workgroups or networks. Simple and cost-effective, the Switch complies to IEEE802.3u, IEEE802.3, 100Base-TX, and 10Base-T. Therefore, the Switch will be the fast being recognized as one of the most important building blocks for today networking technology. Choice of 100Base-FX optic-fiber ST/SC interface,

The FSD-801/1601ST&SC are also ideal to extend the network distance up to 2 kilometers away as a link to your remote backbone.

The Switch also provide rack-mounting kits option for being installed On 10-inch or 19- inch rack to ease the placement and management effort.

Compact in size and designed for Plug and Play installation, the Switch allows the network administrator to simply connect the network and power cables and the switching/bridging functions begin automatically. No hardware or software configurations are required.

The front panel of the Switch provides LED indicators for easy recognition of the switch operation status and for troubleshooting. These LED indicators display the power status for the system and link/activity, speed, and full-duplex status for each port.

With 8/16-port Fast Ethernet Switching designed specifically for connecting workgroup devices and desktops, companies no longer have to invest in expensive and inflexible switches engineered primarily for backbone implementations. Instead, companies can deploy scaleable, affordable switches that increase the aggregate bandwidth of the network by boosting throughput to the workgroups that need it most.

Page 5 of the Planet Technology FSD-1601SC user manual — 1.3 Features
Page 5 · click to enlarge
Page 5

1.3 Features

  • 8/16-port 10/100base-TX Auto-Negotiation Ethernet Switches
  • One optional 100Base-FX fiber port for extending up to 2km
  • Complies with the IEEE802.3 Ethernet and IEEE802.3u Fast Ethernet stan
  • Features Store-and-Forward architectures with wire-speed filtering and for
  • Provide rack-mounting kit option for 10-inch and 19-inch Rack
  • Full/Half-Duplex capability on every TX ports, total bandwidth is up to
  • Support up to 1K/8K Uni-cast address, Layer 2 address resolution-Self Learn
  • IEEE802.3x compliant full-duplex flow control
  • Back pressure half-duplex flow control
  • Runt and CRC Filtering eliminates erroneous packets to optimize the network
  • Provide internal power supply
  • LED indicators for simple diagnostics and management
  • AutoMDI and MDI-X detect for easily connecting to PC or hub/Switch uplink
  • DIP Switch for smart function (16-port model only)
Show 5 more labels / short text on this page
dard · warding rates · 200Mbps/port · ing · bandwidth
Page 6 of the Planet Technology FSD-1601SC user manual — LED indicators
Page 6 · click to enlarge
Page 6

Chapter 2 Hardware Description

This section describes the hardware features of the Switch. For easier management and control of the Switch, familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators. Before connecting any network device to the hub, read this chapter carefully.

2.1 Front Panel

The unit front panel provides a simple interface monitoring the Switch. It includes a power indicator for each port.

2.1.1 FSD-800/FSD-801

Planet Technology FSD-1601SC — 2.1.1 FSD-800/FSD-801 diagram (page 6)
Fig. 1
Planet Technology FSD-1601SC — 2.1.1 FSD-800/FSD-801 diagram (page 6)
Fig. 2

Figure 2-1 Front Panel of FSD-800 / FSD-801

LED indicators

PrintingColorDescription Power (PWR)GreenThis indicator lights green when the Switch is receiving power, otherwise it is off. LNK/ ACTGreenThis indicator green when the port is connected to a either 10Mbps Ethernet or 100Mbs Fast Ethernet station, If the station to which the Switch connected is powered off, or if there is a problem with the link, the LED will remain off. And the indicator blinking green when the data will be re ceived to all other connected ports. 100GreenThis indicator green when the port is connected to a 100Mbps Fast Ethernet station. If the station to which the Switch is connected is powered off, a 10Mbps Ethernet station, or if there is a problem with the link, the LED will remain off.
Page 7 of the Planet Technology FSD-1601SC user manual — 2.1.2 FSD-1600/FSD-1601
Page 7 · click to enlarge
Page 7
LitFull duplex operation
UnlitHalf duplex operation

FDX/

Blinkindicates data collisions on the respective Ethernet

segment of this port. Whenever a collision is detected, the

respective COL indicator will briefly blink.

This is normal when the network is busy.

Port # 8 of FSD-801 is a shared port. Either Twisted Pair port

NOTE:

or Fiber-optic port can operate in one time. Please power off

FSD-801 before switching the share port to different con

nection type.

DIP Switch (FSD-801)

PrintingDescription FDX (default)The 100Base-FX fiber port of the switch is operating in fullduplex mode. HDXThe port is operating in half-duplex mode.

check the opposite end is using the same transmit mode

NOTE:

before make the connection. If you want to adjust the DIP

switch, please power off FSD-801 first.

2.1.2 FSD-1600/FSD-1601

Planet Technology FSD-1601SC — 2.1.2 FSD-1600/FSD-1601 diagram (page 7)
Fig. 3
Planet Technology FSD-1601SC — 2.1.2 FSD-1600/FSD-1601 diagram (page 7)
Fig. 4

Figure 2-2 Front Panel of FSD-1600/ FSD-1601

COL Amber

Page 8 of the Planet Technology FSD-1601SC user manual — 2.2 Rear Panel
Page 8 · click to enlarge
Page 8

LED indicators

PrintingColorDescription Power (PWR)GreenThis indicator lights green when the Switch is receiving power; otherwise, it is off. LNK/ ACTGreenThis indicator green when the port is connected to a either 10Mbps Ethernet or 100Mbs Fast Ethernet station , If the station to which the Switch is connected is powered off, or if there is a problem with the link, the LED will remain off. And the indicator blinking green when the data will be re ceived to all other connected ports. 100GreenThis indicator green when the port is connected to a 100Mbps Fast Ethernet station. If the station to which the Switch is connected is powered off, a 10Mbps Ethernet station, or if there is a problem with the link, the LED will remain off. FDX/ COLAmberLit: Full duplex operation Unlit: Half duplex operation Blink: indicates data collisions on the respective Ethernet segment of this port. Whenever a collision is detected, the respective COL indicator will briefly blink This is normal when the network is busy.

Port # 16 of FSD-1601 is a shared port. Either Twisted Pair

NOTE:

port or Fiber-optic port can operate in one time.

2.2 Rear Panel

There is one power socket on the back of the switch, 100~240VAC, 50/60Hz. And one more DIP-switch for FSD-1600 and FSD-1601 for smart function.

Planet Technology FSD-1601SC — 2.2 Rear Panel diagram (page 8)
Fig. 5 · 2.2 Rear Panel

Figure 2-3 Rear Panel of the FSD-800/801

Planet Technology FSD-1601SC — 2.2 Rear Panel diagram (page 8)
Fig. 6 · 2.2 Rear Panel

Figure 2-4 Rear Panel of the FSD-1600/1601

Page 9 of the Planet Technology FSD-1601SC user manual — DIP Switch (Smart function for FSD-1600/1601)
Page 9 · click to enlarge
Page 9

DIP Switch (Smart function for FSD-1600/1601)

DIPFunctionDescription 1TP / FX SelectionON: Enable FX OFF: Enable TP 2Fiber Full/Half duplex SwitchON: Enable Fiber Full Duplex OFF: Enable Fiber Half Duplex 3VLAN topology type selectionON: 15VLANs (port#1-15) with 1 overlapping port (port#16) topology OFF: 14VLANs (port#1-14) with 2 overlapping port (port#15,16) topology 4Port Based VLANON: Enable VLAN OFF: NO VLAN 5Port Trunk 0 (port 1,2,3,4)ON: Enable Trunk group 0 OFF: Disable group 0 6Port Trunk 1 (port 5,6,7,8)ON: Enable Trunk group 1 OFF: Disable group 1 7Port Trunk 2 (port 9,10,11,12)ON: Enable Trunk group 2 OFF: Disable group 1 8Port Trunk 3 (port 13,14,15,16)ON: Enable Trunk group 3 OFF: Disable group 3 9TCP/IP TOS / DS (Diffserv) Based QoSON: Enable QoS OFF: Turn off the QoS 10802.1Q VLAN Tag Priority Based QosON: Enable OFF: Disable 11&12Port Based Prior ity QoS1211Description OffOffDisable OffOnPort 1-2 high priority ports (2 ports) OnOffPort 1-4 high priority ports (4 ports) OnOnPort 1-8 high priority ports (8 ports)
Page 10 of the Planet Technology FSD-1601SC user manual — 2.3 Hardware Installation
Page 10 · click to enlarge
Page 10
1. For fiber-optic connection, please check the opposite end is us

ing the same transmit mode before make the connection.

2. Port#16 of the switch is shared with 100Base-FX port. Make

NOTE:

sure either Fiber-optic or twisted pair port is being connected.

3. For more information about the Smart function, please refer to

Chapter 3.

4. All the DIP is in OFF position by default!

2.3 Hardware Installation

1. Place the Switch on a smooth surface
2. Connect the output cord of power supply to the AC inlet.
3. Connect hub or PC to one port of the Switch using Category 3/4/5 UTP/STP

cabling.

4. Connect another hub or PC to the other port of Switch by following the same

process as described in Step 3.

Cable distance for the Switch

The cable distance between the Switch and hub / PC should not exceed 100 meter.

The fiber-optic should not exceed 412 meters in Half-duplex mode and 2 kilome ters for Full-duplex mode

Make sure the wiring is correct

It can be used Category 3/4/5 cable in 10Mbps operation. To reliably operate your network at 100Mbps, you must use an Unshielded Twisted-Pair (UTP) Category 5 cable, or better Data Grade cabling. While a Category 3 or 4 cable may initially seem to work, it will soon cause data loss.

The fiber-optic cable should be a multi-mode fiber cable with 62.5/125μm or 50/125μm in specification.

You can find the information from the printing of the cable. If you are not familiar with it, please consult your local dealers for the information.

The Switch accepts AC input with 100~240V AC, 50/60Hz. To prevent from data loss or network downtime, consider install an UPS (Un-interrupt Power Supply) for the Switch. And in some area, a surge suppression device also can help to prevent from the Switch being damaged by un-regulated surge or current to it.

All kinds of hub / PC can connect to switch by using straight-through wires. The Switch also supports auto MDI detection. This means you can direct connect any port of the Switch to another MDI-X devices with a straight wire.

Power System

Page 11 of the Planet Technology FSD-1601SC user manual — Store-and-Forward
Page 11 · click to enlarge
Page 11

Chapter 3 Configuration and Application

This chapter shows you how the Switch works, and how to install the Switch and also to configure the smart functions provided in the 16-port model.

3.1 The Switch Operation

Address Table

The Switch is implemented with an address table. This address table composed of many entries. Each entry is used to store the address information of some node in network, including MAC address, port no, etc. The information comes from the learning process of Ethernet Switch.

Learning

When one packet comes in from any port. The Ethernet Switch will record the source address, port no. and the other related information in address table. These information will be used to decide either forwarding or filtering for future packets.

Forwarding & Filtering

When one packet comes from some port of the Ethernet Switch, it will also check the destination address besides the source address learning. The Ethernet Switch will lookup the address table for the destination address. If not found, this packet will be forwarded to all the other ports except the port which this packet comes in. And these ports will transmit this packet to the network it connected. If found, and the destination address is located at different port from this packet comes in, the Ethernet Switch will forward this packet to the port where this destination address is located according to the information from address table. But, if the destination address is located at the same port with this packet comes in, when this packet will be filtered. Thereby increasing the network throughput and availability

Store-and-Forward

Store-and-Forward is one type of packet-forwarding techniques. A Store-and-Forward Ethernet Switch stores the incoming frame in an internal buffer, do the complete error checking before transmission. Therefore, no error packets occurrence, it is the best choice when a network needs efficiency and stability.

The Switch scans the destination address from the packet header, searches the routing table provided for the incoming port and forwards the packet, only if required. The fast forwarding makes the switch attractive for connecting servers directly to the network, thereby increasing throughput and availability. However, the switch is most commonly used to segment existing hubs, which nearly always improves overall performance. A Ethernet Switch can be easily configured in any Ethernet network environment to significantly boost bandwidth using conventional cabling and adapters.

Due to the learning function of the Ethernet switch, the source address and corresponding port number of each incoming and outgoing packet are stored in a routing table. This information is subsequently used to filter packets whose destination address is on the same segment as the source address. This confines network traffic to its respective

Page 12 of the Planet Technology FSD-1601SC user manual — 3.2.1 TP or Fiber-optic selection (for FSD-1601 only)
Page 12 · click to enlarge
Page 12

domain, reducing the overall load on the network.

The Switch performs “Store-and-forward” therefore, no error packets occur. More reliably, it reduces the re-transmission rate. No packet loss will occur.

Auto-Negotiation

The STP ports on the Switch have built-in "Auto-Negotiation." This technology automatically sets the best possible bandwidth when a connection is established with another network device (usually at Power On or Reset). This is done by detect the modes and speeds at the second of both device is connected and capable of. Both 10Base-T and 100Base-TX devices can connect with the 100Base-TX port in either Half- or Full-Duplex mode.

If attached device is:100Base-TX port will set to: *10Mbps, no auto-negotiation10Mbps *10Mbps, with auto-negotiation10/20Mbps (10Base-T/Full-Duplex) *100Mbps, no auto-negotiation100Mbps *100Mbps, with auto-negotiation100/200Mbps (100Base-TX/Full-Duplex)

3.2 The Smart Function (16-port model)

The FSD-1600 and FSD-1601 is with one DIP switch on the rear of the switch, these ON/ OFF switches provides the functions as below:

  • Twisted Pair or Fiber-optic selection
  • Port based VLAN
  • Port Trunking
  • ToS/ QoS selection
  • Priority Setup

They are all in OFF position by default!

3.2.1 TP or Fiber-optic selection (for FSD-1601 only)

Related DIP1, 2

Default meaning: Port#16 runs in Twisted pair, Auto-Negotiation.

DIP 1: Turns on will force the fiber-optic port enabled.

DIP 2: Turns on will force the 100Base-FX fiber-optic port runs in Full-duplex mode.

Page 13 of the Planet Technology FSD-1601SC user manual — 3.2.4 IP ToS/DS (DiffServ), VLAN Tag Based QoS
Page 13 · click to enlarge
Page 13

3.2.2 Port-based VLAN

Related DIP3, 4

Default meaning: No VLAN setting.

VLAN can be used to separate ports into different groups in the same switch. This will secure port from being accessed by other ports on the switch.

DIP 4Turns on will enable the port-based VLAN capability
DIP 3The two positions represent two different VLAN choices:

OFF:There are 14 VLANs. Port 1 to Port 14 can communicate with Port 15,

and Port 16 where 1 to 14 cannot see each other.

ON: There are 15 VLANs. Port 1 to Port 15 cannot see each other but they

all can retrieve data from port 16. i.e. members of VLAN 1 are 1 & 16, VLAN 2 are 2 & 16, VLAN 3 are 3 & 16, etc.

3.2.3 Port-Trunking

Related DIP5, 6, 7, 8

Default meaning: No port-trunking.

Port trunks will four times the bandwidth (800Mbps) while connecting with another switches that also with port trunk capability. Up to four groups where each group with 4 ports is allowed.

DIP 5: Turns on to enable trunk 0, from port 1 to port 4.

DIP 6: Turns on to enable trunk 1, from port 5 to port 8.

DIP 7: Turns on to enable trunk 2, from port 9 to port 12.

DIP 8: Turns on to enable trunk 3, from port 13 to port 16.

3.2.4 IP ToS/DS (DiffServ), VLAN Tag Based QoS

Related DIP9, 10

Default meaning: No priority-packet detection.

The Switch will store each incoming packets and check the tag field to determine the priority, high or low. Then follow the priority to forward to the destination.

The Switch supports two types of detection.

  • VLAN Tag-based detection (Layer 2)
  • ToS/DS (DiffServ) detection (IP Layer 3)

DIP 9: Turns on for IP ToS/DS QoS.

Page 14 of the Planet Technology FSD-1601SC user manual — 3.3.1 Basic 100Mbps Server, PCs to 10/100Mbps Switch
Page 14 · click to enlarge
Page 14

DIP 10: Turns on for VLAN tag priority QoS.

The connected end-nodes (PCs, Routers) should also support

NOTE:

VLAN priority or ToS priority. Normally, these functions could

turn off by default. Check the user’s guide of your networked

device for this capability.

3.2.5 Port-based priority

Related DIP11, 12

Default meaning: No hardware port priority.

If your end-nodes do not support priority, and you would like to preserve more bandwidth for those network users, port-based priority will direct set the related port to high priority.

DIP 11 DIP 12 Description

ON OFF Port 1 and Port 2 are high priority ports

OFF ON Port 1~ 4 are high priority ports

ON ON Port 1 ~8 are high priority ports

FSD-1600/1601 only support dual priority, this means the

NOTE:

priority only will be HIGH or LOW no matter which port you

connected to.

3.3 Application

3.3.1 Basic 100Mbps Server, PCs to 10/100Mbps Switch

Plug one end of the Category 5 UTP Cable into any one port of the Switch, and the other end of this cable into the RJ-45 of Fast Ethernet Adapter in the server or PC. The cable length between these 2 connecting points should not exceed 100 meters.

Page 15 of the Planet Technology FSD-1601SC user manual — 3.3.2 Connect to 100Base-FX Switch/Device (Model: FSD-801/1601)
Page 15 · click to enlarge
Page 15
Planet Technology FSD-1601SC — 3.3.2 Connect to 100Base-FX Switch/Device (Model: FSD-801/1601) diagram (page 15)
Fig. 7 · 3.3.2 Connect to 100Base-FX Switch/Device (Model: FS…

Figure 3-1 10/100Mbps File server to Switch Connection

3.3.2 Connect to 100Base-FX Switch/Device (Model: FSD-801/1601)

Plug the pair the fiber-cable to the Switch’s fiber-optic port, secure the fiber-optic connector. Connect to other end to the fiber-optic port of the device like repeater hub, switch or workstations.

Be noted for the duplex mode. For Hub, only Half-Duplex mode can be selected, at the mean time, the cable distance cannot exceed 412 meters. For Switch or end-node that works on full-duplex mode, the maximum distance cannot exceed 2 kilometers.

The pair of the connectors must be crossed, ie. TX/RX port of the Switch should connect to RX/TX Port of the device in other end.

Consult your local dealer for more information about fiber-optic wires, connector type or network distances.

Planet Technology FSD-1601SC — 3.3.2 Connect to 100Base-FX Switch/Device (Model: FSD-801/1601) diagram (page 15)
Fig. 8 · 3.3.2 Connect to 100Base-FX Switch/Device (Model: FS…

Figure 3-2 Fiber-cable Switch to Switch Connection

Page 16 of the Planet Technology FSD-1601SC user manual — 3.3.4 Set up Video/Voice Networks (Model: FSD-1600/1601)
Page 16 · click to enlarge
Page 16

3.3.3 Set up the workgroup and uplink to the backbone (Model: FSD1600/1601)

Planet Technology FSD-1601SC — 3.3.3 Set up the workgroup and uplink to the backbone (Model: FSD1600/1601) diagram (page 16)
Fig. 9 · 3.3.3 Set up the workgroup and uplink to the backbon…

Figure 3-3 Connection with VLAN enable

Turn on the DIP 4, the FSD-1600 soon separate the fourteen ports (Port 1 to Port 14) into different group, then you can install two file servers to port 15, port 16, those fourteen users shall not see each other where they can freely access the information from the two file server. Or, port 15 is connect to your local server and port 16 up connect to your networks backbone, either 100 meters (FSD-1600) or 2 kilometers away (FSD-1601, both DIP 1 & 2 in ON position)

3.3.4 Set up Video/Voice Networks (Model: FSD-1600/1601)

Some networks could have a devices like Video or Voice device like Internet Telephony Gateway, the support of priority may help you to make your voice or video in higher position to get the precious networks bandwidth, for example to the Intermet.

If your Voice Gateway support ToS, you may direct turn on the DIP 9 to get the higher priority, or if your device or network nodes do not support you can turn on DIP 11 or DIP 12 to have the hardware priority,

Planet Technology FSD-1601SC — 3.3.4 Set up Video/Voice Networks (Model: FSD-1600/1601) diagram (page 16)
Fig. 10 · 3.3.4 Set up Video/Voice Networks (Model: FSD-1600/1…

Figure 3-4 3 Voice Gateway to Switch Connection

Page 17 of the Planet Technology FSD-1601SC user manual — Chapter 4 Troubleshooting
Page 17 · click to enlarge
Page 17

Chapter 4 Troubleshooting

This chapter contains information to help you solve problems. If the Switch is not functioning properly, make sure the Switch was set up according to instructions in this manual.

The Link LED is not Lit

Solution:

Make sure the switch configuration is consistent with the connecting device

Check the cable connections.

Solution:

Check the full duplex status of the Ethernet Switch. If the Ethernet Switch is set to full duplex and the partner is set to half duplex, then the performance will be poor.

Some stations can not talk to other stations located on the other port

Solution:

The address table may contain older information than of the address table of that node. Please power down to refresh the address information.

Performance is bad

Page 18 of the Planet Technology FSD-1601SC user manual — (LINK/ACT, 100, FDX/ COL)
Page 18 · click to enlarge
Page 18

Appendix A Specifications

StandardsIEEE 802.3 10Base-T EthernetIEEE 802.3u 100 Base-TX and

100Base-FX Fast EthernetIEEE 802.3x Flow control

ProtocolCSMA/CD

Ethernet:

10Mbps(half duplex) / 20Mbps (full duplex) Fast Ethernet:

Rate:

100Mbps (half duplex) / 200Mbps (full duplex)

TopologyStar
  • 10Base-T:2-pair UTP Cat. 3,4, 5 (100 m, max.)EIA/TIA-

568 100-ohm STP (100 m, max.)

  • 100Base-TX:2-pair UTP Cat. 5 (100 m, max.)EIA/TIA-568

Network Cables:

100-ohm STP (100 m, max.)

  • 100Base-FX: (Models: FSD-4/8/1601)

1-pair Multi-mode optic fiber 62.5/125μm, 50/125μm(2

km, max.)

Models:FSD-8/1601

Ports:

1-ST/SC fiber-optic port (1300nm wavelength)

Hardware Physical /Environmental Specification

AC inputs 100~240VAC, 50/60Hz

LED Indication SystemPowerPort: 3 LED Indicators per port

(LINK/ACT, 100, FDX/ COL)

perature 0 ~ 50 degree C

perature -20 ~ 70 degree C

Humidity 10% ~ 90% non-condensing

Dimensions 220 x 135 x 44 mm (W x D x H)

Show 9 more labels / short text on this page
General (Ethernet) · Data Transfer · General (Cabling) · 8/16-STP ports · Number of · Power Con · sumption 15~25 watts · Operating Tem · Storage Tem
Page 19 of the Planet Technology FSD-1601SC user manual — Specifications
Page 19 · click to enlarge
Page 19

EMI FCC Class A, CE Mark Class A

14,880pps per port (for 10Mbps)

148,800pps per port (for 100Mbps)

Learning Automatic update / Max age: fixed

Show 8 more labels / short text on this page
Performance · Transmission · Method Store-and-forward · Filtering Address · Table 1/8K entries · Packet Filtering/ · Forwarding Rate · MAC Address
Page 20 of the Planet Technology FSD-1601SC user manual — Appendix B RJ-45 Pin Specification
Page 20 · click to enlarge
Page 20

Appendix B RJ-45 Pin Specification

When connecting your FSD-series 10/100Mbps Ethernet Switch to another switch, a bridge or a hub, a modified crossover cable is not necessary. Each port of the Switch is auto-MDI detection. That means you can direct connect the Switch to any Ethernet devices with a Category 5, UTP straight wire.

However, the following diagram and tables also show the standard RJ-45 receptacle/ connector and their pin assignments for the switch-to-network adapter card connection, and the straight / crossover cable for the Switch-to-switch/hub/bridge connection.

RJ-45 Connector pin assignment

Contact Media Direct Interface Signal Media Direct Interface -Cross

1 TX + (transmit) Rx + (receive)

2 TX - (transmit) Rx - (receive)

3 Rx + (receive) TX + (transmit)

4, 5 Not used

6 Rx - (receive) TX - (transmit)

7, 8 Not used

The standard cable, RJ-45 pin assignment

Planet Technology FSD-1601SC — Appendix B RJ-45 Pin Specification diagram (page 20)
Fig. 11 · Appendix B RJ-45 Pin Specification

The standard RJ-45 receptacle/connector

Page 21 of the Planet Technology FSD-1601SC user manual — RJ-45 Pin Specification
Page 21 · click to enlarge
Page 21

This page is intentionally left blank

Page 22 of the Planet Technology FSD-1601SC user manual — RJ-45 Pin Specification
Page 22 · click to enlarge
Page 22
Page 22 of the Planet Technology FSD-1601SC user manual — RJ-45 Pin Specification
Page 23 of the Planet Technology FSD-1601SC user manual — RJ-45 Pin Specification
Page 23 · click to enlarge
Page 23

Part No.: 2010-000004-003

Ask about the Planet Technology FSD-1601SC

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Planet Technology FSD-1601SC

Be the first to ask — other owners or our team will answer.

Original document

Planet Technology FSD-1601SC manual PDF

23 pages·532 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…