T8 COLLECTION
† This lamp is better for the environment because of
its reduced mercury content.All Philips ALTO® lamps give you end-of-life options which can simplify and reduce your lamp disposal costs depending on your state and local regulations.
Philips PLUS T8 U-Bent Lamps are environmentally- responsible lamps that offer long life and low mercury.
* The PLUS 32WT8 has a rated average life of 30,000 hours compared to an industry standard 4'T8 32W U-Bent lamp with 24,000 hours rated average life (12 hrs per start on an instant start ballast with 2800 lumens and 85 CRI)

Ordering, Electrical andTechnical Data
Color Nom. Rated Average Life (Hrs.)1 Approx. Product Ordering Pack. Temp. Length 12-hr on 12-hr on Initial Design Lumen Number Code Watts Qty. (Kelvin) (In.) Ins. Start2 Prog. Start2 Lumens3 Lumens4 CRI Maint.
21977-4 FB32T8/TL830/PLUS/6/ALTO 32 20 3000 227⁄16 30,000 36,000 2800 2535 85 95% 21978-2 FB32T8/TL835/PLUS/6/ALTO 32 20 3500 227⁄16 30,000 36,000 2800 2535 85 95% 21983-2 FB32T8/TL841/PLUS/6/ALTO 32 20 4100 227⁄16 30,000 36,000 2800 2535 85 95% 21987-3 FB32T8/TL850/PLUS/6/ALTO 32 20 5000 227⁄16 30,000 36,000 2750 2500 84 95%
1) Rated average life is the length of operation (in hours) at which point an average of 50% of a large sample of lamps will still be operational and 50% will not. 2) Average life under engineering data with lamps turned off and restarted once every 12 operating hours. Lamp life is appreciably longer if lamps are started less frequently. 3) Approximate initial lumens.The lamp lumen output is based upon lamp performance after 100 hours of operating life, when the output is measured during operation on a reference ballast under standard laboratory conditions. For expected lamp lumen output, commercial ballast manufacturers can advise the appropriate ballast factor for each of their ballasts when they are informed of the designated lamp.The ballast factor is a multiplier applied to the designated lamp lumen output. 4) Design lumens are the approximate lamp lumen output at 40% of the lamp’s rated average life.This output is based upon measurements obtained during lamp operation on a reference ballast under standard laboratory conditions.
24,000
30,000
BASED ON 12 HOURS PER START 2
30,000

0 10,000 20,000 30,000 40,000
Rated Average Life in Hours
© 2008 Philips Lighting Company.All rights reserved. Printed in USA 4/08
Philips Lighting Company 200 Franklin Square Drive P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050
www. philips.com
A Division of Philips Electronics North America Corporation
A Division of Philips Electronics Ltd.
Instant Start Ballast · Programmed Start Ballast