EN
Philips logo
Official user manual

Philips LP-11

2 pages·270 KB·Work Light·PDF·ENDEFRITNLJA
Philips LP-11
Table of Contents 13 sections Lighting Systems LP-11 · Module Ordering Information · LP 2 2T8 B · Features 1. Housing: · … ShowHide
Page 1 of the Philips LP-11 user manual — Features 1. Housing:
Page 1 · click to enlarge
Page 1

Lighting Systems LP-11

1BHFPG -JOFBS1FSG-ZUFÜ DN 4FNJ1FSGPSBUFE-JHIU51FS'PPU /PNJOBM 4FDUJPO

Philips LP-11 — Lighting Systems LP-11 diagram (page 1)
Fig. 1 · Lighting Systems LP-11

Module Ordering Information

Length Lamps Type Ballast

LP 2 2T8 B

2T8 = 2F32T8 4 = 4-Foot U = Universal Voltage Blank = No Options 8 = 8-Foot E = Emergency Pack DS = A-B Switch D1 = Dimming 120v X4 = 4 Wire for Dimming &

Complete ordering instructions below.

Switched Emergency D2 = Dimming 277v

Features 1. Housing:

Ordering Information Individual Fixtures: 1. Order number of MODULES required. 2. Order one POWER FEED END SET per MODULE.

18 gauge perforated steel with 51% open hole pattern. Holes are 1/8” (0.32cm) diameter on 5/32” (0.40cm) centers. Die-formed steel end cap with concealed access holes for through wiring. No exposed fasteners or hardware.

Continuous Rows: 1. Determine run length. 2. Order the appropriate number of MODULES for the complete run. 3. Order one POWER FEED END SET per run. 4. Order one CABLE ASSEMBLY per MODULE minus one per run. 5. For runs that exceed amperage limits, order the appropriate number of SINGLE

others. 2. LampingTwo T8 32 watt fluorescent lamps per 4-foot section. Provided by
3. Reflector: Precision die-formed specular aluminum
4. Diffuser: Opal acrylic diffuser.

Electrical Ballast is universal voltage,

CABLE & CORD FEEDS.

Finish Powder coated baked white enamel. Custom colors available, consult factory.

Labels UL, cUL and I.B.E.W.

Mountings Cable Suspension (not shown) - 4-1/2” (11.43cm) diameter flat canopy finished white enamel, 1/16” (0.16cm) diameter stainless steel aircraft cable adjustable up to 36” (91.44cm) without cutting. Overlap connector to provide 46” (116.84cm) of perforated and 2” (5.08cm) solid sections contiguously without the presence of hairline connections. (See Bottom View drawing above)

Philips LP-11 — Features 1. Housing: diagram (page 1)
Fig. 2 · Features 1. Housing:

Options Dual Switching: Order the DS option for separate row switching. DS option automatically ships with the X4 option included.

4 Wire: Order X4 modules for remainder of the run when using dimming and/or switched emergency battery pack modules. Also, order the 4 Wire Cord Power Feed End Sets (LP2EC36X4) when using 4 Wire Modules. Emergency Circuiting: Special circuiting - consult factory.

"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt

Bottom View · Style Series Options · #

Page 2 of the Philips LP-11 user manual — Job Information Type:
Page 2 · click to enlarge
Page 2

Lighting Systems LP-11

1BHFPG -JOFBS1FSG-ZUFÜ DN 4FNJ1FSGPSBUFE-JHIU51FS'PPU /PNJOBM 4FDUJPO

Performance

CANDLEPOWER CURVE

CANDLEPOWER ZONE 0 22 45 67 90 DEG.

COEFFICIENTS OF UTILIZATION

Philips LP-11 — COEFFICIENTS OF UTILIZATION diagram (page 2)
Fig. 3

% EFFECTIVE CEILING CAVITY

REFLECTANCE

CANDELAS 180 810 175 801 811 820 855 838 165 773 825 873 924 933 155 719 815 915 1013 1042 145 621 765 922 1079 1128 135 496 678 890 1075 1120 125 391 613 878 1095 1119 115 253 507 779 976 1064 105 129 382 691 763 781 95 35 197 269 266 270 90 11 17 26 27 31 85 6 16 24 30 33 75 19 23 34 42 46 65 28 35 46 54 58 55 61 65 76 83 82 45 78 79 84 91 94 35 101 102 105 109 110 25 119 119 121 123 124 15 130 130 132 132 132 5 137 135 136 136 137 0 136

807050 WALL REFLECTANCE 70 50 30 70 50 30 50 30 1 0 1 2 3 4 5 6 7 8 9 1079 79 79 72 68 65 65 60 55 60 53 47 54 46 40 50 41 35 46 37 30 42 33 27 39 29 23 36 27 21 33 24 1969 69 69 62 59 57 57 52 48 52 46 41 47 40 35 43 36 31 39 32 27 36 29 23 33 26 21 31 23 18 29 21 1649 49 4 43 41 4 37 35 3 33 30 2 29 26 2 26 23 2 23 20 1 21 17 1 19 15 1 17 14 11 15 12 10
Philips LP-11 — % EFFECTIVE CEILING CAVITY diagram (page 2)
Fig. 4

ROOM CAVITY RATIO

DISTRIBUTION Zone Lumens % Lamp % Luminaire 0-90 409 7.1 8.7 90-180 4306 74.2 91.3 0-180 4714 81.3 100.0

REPORT NOLRL 200-10C CAT NO: LP2B2T84U LAMPS: 2 F32T8 LUMENS: 2900 EFFICIENCY: 81.3%

Fixture Lengths & Mounting Locations

Philips LP-11 — Fixture Lengths & Mounting Locations diagram (page 2)
Fig. 5 · Fixture Lengths & Mounting Locations
4-Foot Module8-Foot ModuleEnd SetCable/ Joiner 4-Foot Run11 8-Foot Run11 12-Foot Run1111 16-Foot Run211 20'-Foot Run1212 24'-Foot Run312

Mounting Accessories

Cable/Joiner Assembly Standard Cable Length is 36” (91.44cm) Single Cable: LP2C36 Single Cable & Cord: LP2CC36 Single Cable & 4 Wire Cord: LP2CC36X4 * use for dimming and/or emergency battery packs

Power Feed End Set Standard Cable Length is 36” (91.44cm) Straight Cord: LP2EC36 4 Wire Cord*: LP2EC36X4

Ceiling Grid Kit CGK Includes both Standard 1” (2.54cm) Tee Bar Clip & Slot Tee Clip

Job Information Type:

"JSQPSU3PBE 'BMM3JWFS ."t t'BY We reserve the right to change details of design, materials and finish. XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt #

Show 4 more labels / short text on this page
12’ · 16’ · 20’ · 24’

Ask about the Philips LP-11

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Philips LP-11

Be the first to ask — other owners or our team will answer.

Original document

Philips LP-11 manual PDF

2 pages·270 KB·Work Light·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…