Page 1 of 2 Explosion Proof Power Packs
The HC Series is ideal for use in hazardous locations where explosive materials may be present. The HC Series is UL listed for use in Class I, Division 1, Groups C & D; Class II, Division 1, Groups E, F & G areas.

Complete Fixture consists of power pack unit. Order lighting fixtures separately. Select options below.
SERIES VOLTAGE/BATTERY
HC = Hazardous Location Emergency Lighting Unit
6V, Nickel Cadmium 14N = 14W Power Pack, Compact Fluorescent Lamp Operation, AC and Emergency Operation1 28N = 28W Power Pack, Incandescent Lamp Operation, Emergency Operation Only 6V, Pure Lead 85P = 85W Power Pack, Incandescent Lamp Operation, Emergency Operation Only 12V, Nickel Cadmium 50N = 50W Power Pack, Incandescent Lamp Operation, Emergency Operation Only
Features 1. Illumination: Illumination is accomplished with incandescent or compact fluorescent F Series Fixtures. (See F Series Spec Sheet.) 2. Housing: Copper-free cast aluminum enclosure designed to withstand the pressure of explosions generated by internal arc without propagating them into the hazardous atmosphere. 3. Electronics: 120/277 VAC dual voltage input with surge-protected, solid- state circuitry. HC85P uses a temperature compensating charger. Charging system is complete with low voltage disconnect, AC lockout, brownout pro- tection, AC indicator lamp and test switch. 4. Battery: Maintenance free, sealed nickel cadmium battery has an estimat- ed service life of 10 years, and an operating temperature range of 20°F (-7°C) to 95°F (35°C). HC85P uses a pure lead battery. 5. Input Power Requirements: 120 VAC - 0.50 amps, 60 watts 277 VAC - 0.22 amps, 60 watts
Accessories OB3 = 3-way explosion proof 3/4” conduit hub SEA = Swivel elbow arm for use with pendant mount fixture to connect to OB3 or HC unit EVLA12 = 12 Volt, 12 Watt Halogen Directional Head
9.0” (22.86 cm)
4.6” (11.68 cm)
9.0” (22.86 cm)
Code Compliance UL 924, 844, 1203 and 1604 listed.
Job Name:
Options T1 = 120 VAC Time Delay T2 = 277 VAC Time Delay DC = DC Power Switch ST = Special Input Transformer (Specify voltage & frequency) KL = Key Lock
Cat. No.:
Lamp(s):

Page 2 of 2 Explosion Proof Power Packs
The sample application below consists of: (1) HC14N - 14 watt power pack for exclusive use with compact fluorescent fixtures (2) SEA - Elbow arms (1) FPHFP7 - 7 watt compact fluorescent lamp fixture (operates in AC and emergency mode) See F Series Spec Sheet. (1) FPHFP7EFK - 7 watt compact fluorescent lamp fixture with exit accessory (operates in AC and emergency mode) See F Series Spec Sheet.

* Per NEC Specifications