Part No. DUA1670-8AAA01 Published March 2005

3Com Corporation 350 Campus Drive Marlborough, MA USA 01752-3064
Copyright © 2005, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hard copy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
3Com, OfficeConnect, and the 3Com logo are registered trademarks of 3Com Corporation.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
Netscape Navigator is a registered trademark of Netscape Communications.
JavaScript is a trademark of Sun Microsystems.
All other company and product names may be trademarks of the respective companies with which they are associated.
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we are committed to:
Establishing environmental performance standards that comply with national legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement 3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
Regulated Materials Statement 3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation The documentation for this product is printed on paper that comes from sustainable, managed forests; it is fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly, and the inks are vegetable-based with a low heavy-metal content.
This product contains encryption and may require U.S. and/or local government authorization prior to export or import to another country.

Before You Start 7 About Your CD-ROM 7 Conventions 8 Related Documentation 9 Accessing Online Documentation 9 Documentation Comments 10
1 INTRODUCING THE OFFICECONNECT MANAGED SWITCH 9 AND SWITCH 9 FX
About the Switch 12 Summary of Hardware Features 12 Switch — Front View Detail 13 LEDs 14 Switch — Rear View Detail 16 10BASE-T/ 100BASE-TX Ports 17 10BASE-T/ 100BASE-TX/ 1000BASE-T Port 17 SFP Port 17 100BASE-FX Port 18 Console Port 18 Power Socket 18 Default Settings 19
Package Contents 22 Choosing a Suitable Site 22 Placing Units On Top of Each Other 23 Using a Stacking Clip 23 Wall-mounting 24

Mounting Instructions for Cement Walls 24 Mounting Instructions for Wood Walls 25 The Power-up Sequence 25 Powering-up the Switch 25 Checking for Correct Operation of LEDs 26 Using Power over Ethernet 26 Choosing the Correct RJ-45 Cables 28 SFP Operation 29 Approved SFP Transceivers 29 Inserting an SFP Transceiver 29 Removing an SFP Transceiver 31
Setting Up Overview 34 IP Configuration 35 Preparing for Management 36 Manually Configuring IP Information 37 Connecting to the Console Port 37 Viewing Automatically Configured IP Information 40 Using 3Com Network Supervisor 40 Connecting to the Console Port 41 Methods of Managing a Switch 43 Command Line Interface Management 43 Web Interface Management 44 SNMP Management 44 Setting Up Command Line Interface Management 45 CLI Management via the Console Port 45 CLI Management over the Network 45 Setting Up Web Interface Management 46 Pre-requisites 46 Web Management Over the Network 47 Setting Up SNMP Management 47 Pre-requisites 48 Default Users and Passwords 48 Changing Default Passwords 48

Solving Problems Indicated by LEDs 52 Solving Hardware Problems 53 Solving Communication Problems 54 Solving Software Upgrade Problems 55 Recovering from a Lost Password 55
Power Cord Set — Japan 58 Important Safety Information 58 L’information de Sécurité Importante 60 Wichtige Sicherheitsinformationen 62 Información de seguridad importante 64 Importanti Informazioni di Sicurezza 66
RJ-45 to RS-232 Adapter Cable 69 RJ-45 Pin Assignments 70
OfficeConnect Managed Switch 9 and Switch 9 FX 71
Register Your Product 73 Purchase Value-Added Services 73 Troubleshoot Online 74 Access Software Downloads 74 Telephone Technical Support and Repair 74 Contact Us 75
R EGULATORY N OTICES



This guide provides all the information you need to install and use the following switches in their default state.
All procedures described in this guide apply to both models except where stated. Where a procedure or description applies to both the Switch 9 and the Switch 9 FX, the term Switch is used.
The guide is intended for use by network administrators who are responsible for installing and setting up network equipment; consequently, it assumes a basic working knowledge of LANs (Local Area Networks).
Before You Start This section contains information about the CD-ROM that accompanies your Switch.
About Your CD-ROM The CD-ROM also contains the following:
Most user guides and release notes are available in Adobe Acrobat Reader Portable Document Format (PDF) or HTML on the 3Com World Wide Web site:

Conventions Table 1 and Table 2 list conventions that are used throughout this guide.
Table 1 Notice Icons
Table 2 Text Conventions

In addition to this guide, each Switch documentation set includes the following:
This guide contains information on the features supported by your Switch and how they can be used to optimize your network. It is supplied in PDF format on the CD-ROM that accompanies the Switch.
This guide contains:
This guide provides detailed information about the Web interface and command line interface that enable you to manage the Switch. It is supplied in HTML format on the CD-ROM that accompanies the Switch.
These notes provide information about the current software release, including new features, modifications, and known problems.
There are other publications you may find useful, such as:
To access the documentation on the CD-ROM supplied with your Switch, do the following:
1 Insert the CD-ROM into your CD-ROM drive. If your PC has auto-run enabled, a splash screen will be displayed automatically.
2 Select the Documentation section from the contents page.
Related Documentation 9

If the online documentation is to be accessed from a local drive or server, you will need to access the CD-ROM contents via the root directory and copy the files from the CD-ROM to a suitable directory.
3Com recommends that you copy the Docs/reference directory as a whole to maintain the structure of the files.
Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments about this document to 3Com at:
Please include the following information when commenting:
Example:
Please note that we can only respond to comments and questions about 3Com product documentation at this e-mail address. Questions related to technical support or sales should be directed in the first instance to your network supplier.

1 INTRODUCING THE OFFICECONNECT MANAGED SWITCH 9 AND SWITCH 9 FX
This chapter contains introductory information about the Switch 9 and Switch 9 FX and how they can be used in your network. It covers summaries of hardware and software features and also the following topics:

12 CHAPTER 1: INTRODUCING THE OFFICECONNECT MANAGED SWITCH 9 AND SWITCH 9 FX
About the Switch The Switch is a 10/100 Mbps Ethernet Switch, which consists of:
and either:
The 100BASE-FX and SFP port is a combination port. When an SFP module is inserted it has priority over the 100BASE-FX port of the same number. The corresponding 100BASE-FX port is disabled when an SFP module is present.
The Switch supports Power over Ethernet on ports 1, 2, 5 and 6. If you plug in a compatible (IEEE 802.3af compliant) device, it will be automatically detected and power supplied to it. Power over Ethernet is enabled on these ports by default.
Table 3 summarizes the hardware features that are supported by the Switch.
Table 3 Hardware features

Switch — Front View Detail 13

Port Status LEDS PoE Status LEDS Power LED Alert LED
Blue = 1000M, Green = 100M, Yellow = 10M, Flash = Activity
Figure 1 Switch 9 — front view

Green = 100M, Yellow = 10M, Flash = Activity
Figure 2 Switch 9 FX — front view

14 CHAPTER 1: INTRODUCING THE OFFICECONNECT MANAGED SWITCH 9 AND SWITCH 9 FX
LEDs Table 4 lists LEDs visible on the front of the Switch, and how to read their status according to color. For information on using the LEDs for problem solving, see “Solving Problems Indicated by LEDs” on page 52.
Table 4 LED behavior
10BASE-T/100BASE-TX Port Status LEDs
Green A 100 Mbps link is present.
Yellow A 10 Mbps link is present.
Green flashing There is 100 Mbps activity on the port.
Yellow flashing There is 10 Mbps activity on the port.
Off No link is present.
Duplex Green The port is operating at full duplex
Off The port is operating at half duplex, or there is no link.
10BASE-T/100BASE-TX/1000BASE-T (GbE) Port Status LED (Switch 9 only)
Blue A 1000 Mbps link is present.
Green A 100 Mbps link is present.
Yellow A 10 Mbps link is present.
Blue flashing There is 1000 Mbps activity on the port.
Green flashing There is 100 Mbps activity on the port.
Yellow flashing There is 10 Mbps activity on the port.
Off No link is present.
Duplex Green The port is operating at full duplex
Off The port is operating at half duplex, or there is no link.
SFP Module Status LED (Switch 9 FX only)
Green The port has a link.
Green flashing There is activity on the port.
Off No link is present.
Green The SFP Module is present. The corresponding 100BASE-FX port is disabled.
Off No SFP Module has been inserted. The corresponding 100BASE-FX port can be used.
100BASE-FX Port Status LEDs (Switch 9 FX only)
Green The port has a link.
Green Flashing There is activity on the port.
Off No link is present.

Switch — Front View Detail 15
PoE Status LED (Ports 1, 2, 5, 6)
Green Power is being delivered to the attached device.
Off No power is being delivered to the attached device, or no device is attached to this port.
Green The Switch is powered-up and operating normally.
Off The Switch is not receiving power or there is a fault with the Power Supply Unit.
Power OK LED (rear panel)
Green The power adapter is providing power normally.
Off The power adapter has probably failed (see Chapter 4, “Problem Solving”).
Orange flashing The Switch is starting up or the Switch software is being
upgraded.
Orange The Switch is reporting a fault (see Chapter 4, “Problem Solving”), or a user-configured alert condition has occurred (see the Implementation Guide for information on configuring alert conditions).
Off The Switch is powered-up and operating normally (if the Power LED is on).
LED Color Indicates · Power LED · Alert LED

16 CHAPTER 1: INTRODUCING THE OFFICECONNECT MANAGED SWITCH 9 AND SWITCH 9 FX

Figure 3 Switch 9 — rear view

Figure 4 Switch 9 FX — rear view
Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.

Switch — Rear View Detail 17
10BASE-T/ 100BASE-TX Ports The Switch has 8 auto-negotiating 10BASE-T/100BASE-TX ports configured as Auto MDI/MDI-X. These ports automatically provide the appropriate connection. The default state for 10/100 Mbps ports is auto-negotiation enabled, where the speed, duplex and flow control modes are negotiated.
Alternatively, you can manually set these ports to 10BASE-T half duplex, 10BASE-T full duplex, 100BASE-TX half duplex, 100BASE-TX full duplex and manually enable or disable flow control. The maximum segment length is 100 m (328 ft) over Category 5 twisted pair cable.
If you disable auto-negotiation, Auto MDI/MDI-X will also be disabled.
The Switch will supply up to 15.4W of power through ports 1, 2, 5 and 6 in conformance to the 802.3af specification. The Switch incorporates a PoE Status LED on the front panel, which indicates when power is being delivered to a device connected to one of these ports.
The Switch 9 has one auto-negotiating 10BASE-T/100BASE-TX/1000BASE-T port configured as Auto MDI/MDI-X. This port automatically provides the appropriate connection. The default state for the 10/100/1000 Mbps port is auto-negotiation enabled, where the speed, duplex and flow control modes are negotiated.
Alternatively, you can manually set these ports to 10BASE-T half duplex, 10BASE-T full duplex, 100BASE-TX half duplex, 100BASE-TX full duplex or 1000BASE-T full duplex and manually enable or disable flow control. The maximum segment length is 100 m (328 ft) over Category 5 twisted pair cable.
If you disable auto-negotiation, Auto MDI/MDI-X will also be disabled.
SFP Port The Switch 9 FX has one SFP (Small Form Factor Pluggable) port that supports Gigabit Ethernet short-wave (SX) or long-wave (LX) fiber-optic SFP transceivers, or Gigabit Ethernet 1000BASE-TX SFP transceivers. This offers you the flexibility of using SFP transceivers to provide connectivity between the Switch and a 1000 Mbps core network or to create a high capacity aggregated link between two workgroups.
When using fiber-optic SFP transceivers, the only state for this port is auto-negotiation enabled. As the speed and duplex modes are fixed by the media type, only the flow control is negotiated with the link partner.

18 CHAPTER 1: INTRODUCING THE OFFICECONNECT MANAGED SWITCH 9 AND SWITCH 9 FX
When an SFP module is inserted it has priority over the 100BASE-FX port. The corresponding 100BASE-FX port is disabled when an SFP module is present.
100BASE-FX Port The Switch 9 FX has one 100BASE-FX LC port. This is a 100 Mbps fiber-optic port that can use standard multi-mode fiber-optic cable of up to 2 kilometers (1.2 miles). It uses the standard duplex LC connector that allows both the transmit and the receive fibers to be connected in the same space as an RJ-45 port.
When an SFP module is inserted it has priority over the 100BASE-FX port. The corresponding 100BASE-FX port is disabled when an SFP module is present.
Console Port The console port allows you to connect a terminal and perform local out-of-band management. The console port uses an RJ-45 to DB-9 null modem cable (supplied with the Switch) and is set to 19200 baud, 8 data bits, no parity and 1 stop bit.
The default configuration automatically detects any of the following baud rates: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200. However, you must set the baud rate on your management device to 19200 baud if you want to view all the system initialization messages.
Power Socket The power adapter supplied with the Switch automatically adjusts its power setting to any supply voltage in the range 100-240 VAC. Only use the adapter provided with the Switch.

Default Settings Table 5 shows the default settings for the Switch:
Table 5 Default Settings
IP Configuration Automatic by DHCP client
Port Speed ■ 10BASE-T/100BASE-TX ports are auto-negotiated
Duplex Mode ■ 10BASE-T/100BASE-TX port is auto-negotiated
Power over Ethernet Enabled (ports 1, 2,5 and 6)
Flow Control ■ Disabled in half duplex 10/100 ports
Broadcast Storm Control Enabled
Virtual LANs (VLANs) All ports belong to the untagged Default VLAN (VLAN 1) with IEEE Std 802.1Q-1998 learning operational
Multicast Filtering IGMP Filtering enabled
Rapid Spanning Tree Protocol Enabled
Spanning Tree Fast Start ■ Disabled on 10/100 ports
Traffic Prioritization All ports prioritize NBX VoIP traffic (LAN and IP). All ports set to “best effort” for all other traffic.
Port Security Disabled per port
Default Settings 19 · Feature Switch · Port Status Enabled

20 CHAPTER 1: INTRODUCING THE OFFICECONNECT MANAGED SWITCH 9 AND SWITCH 9 FX
If you initialize a Switch unit by selecting System > Control > Initialize in the Web interface or by entering system control initialize in the Command Line Interface, the following settings are retained to allow you to connect to and manage the Switch:

This chapter contains the information you need to install and set up the Switch. It covers the following topics:

procedura di manutenzione, leggere le informazioni di sicurezza riportate nell'Appendice A della presente guida per l'utente.
Package Contents ■ Switch unit
The Switch is suited for use on a desktop, either free standing, stacked together with other units using the stacking clip, or mounted on a wall. Alternatively, the Switch can be placed in a wiring closet or equipment room, as an aggregator for other Hubs and Switches. A stacking kit containing one mounting clip is supplied with the Switch.
When deciding where to position the Switch, ensure that:

Placing Units On Top of Each Other 23
If the Switch is stacked with other OfficeConnect units its local air temperature may be greater than room ambient temperature.
If the Switch units are free-standing or stacked together with the stacking clip, up to four units can be placed one on top of the other. If you are mixing a variety of OfficeConnect Switch and Hub units, the smaller units must be positioned at the top.
If you are placing free-standing Switch units one on top of the other, you must use the supplied self-adhesive rubber pads to prevent the Switch from moving around on your desk, or when stacking with flat top OfficeConnect units. Apply the pads to the underside of each Switch, sticking one in the marked area at each corner.
Use a stacking clip when stacking your Switch with other curved OfficeConnect units. The stacking clip allows you to stack units neatly and securely.
To fit the clip:
1 Fit the clip across the top of the unit, as shown in Figure 5 (picture 1).
2 Align the fastening pieces over the slots found on each side of the unit.
3 Push the clip down gently to secure it, ensuring that the fastening pieces snap into the slots on the unit.

To fit another unit:
1 Rest the second unit on the top of the clip and align it with the front of the unit below.
2 Press down gently on the unit to secure in onto the clip, ensuring the fastening pieces fit into the slots on the unit below, as shown in Figure 5 (picture 2).
Figure 5 Stacking Your Units together

Wall-mounting There are two slots on the underside of the Switch that can be used for wall mounting. The Switch must be mounted with the LEDs facing upwards.
When wall mounting the unit, ensure it is within reach of the power outlet.
When wall mounting the unit, ensure that the rubber feet are not fixed.
To wall mount the unit on a cement wall, follow these instructions:
1 Make two holes 150 mm (5.9 in.) apart and insert two nylon or similar screw anchors that are suitable for the wall construction.
2 Fix two suitable screws into the anchors, leaving their heads 3 mm (0.12 in.) clear of the wall surface. The screws should be at least 30 mm (1.2 in.) long.
3 Remove any connections from the Switch and locate it over the screw heads. When in line, gently push the Switch on to the wall and move downwards to secure.

The Power-up Sequence 25
To wall mount the unit on a wood wall, follow these instructions:
1 Make two holes 150 mm (5.9 in.) apart.
2 Fix two suitable screws directly into the wall, leaving their heads 3 mm (0.12 in.) clear of the wall surface. The screws should be at least 20 mm (0.75 in.) long.
3 Remove any connections from the Switch and locate it over the screw heads. When in line, gently push the Switch on to the wall and move downwards to secure.
The following sections describe how to get your Switch powered-up and ready for operation.
Use the following sequence of steps to power-up the Switch.
1 Plug the power adapter into the power socket at the rear of the Switch.
2 Plug the other end of the power cord into your power outlet.
3 The Alert LED will flash orange while the Switch is starting up.
4 When the unit is ready, the Power LED lights green and the Alert LED is off.
The Switch powers-up and runs through its Power On Self Test (POST), which takes approximately 60 seconds.

During the Power On Self Test, all ports on the Switch are disabled. When the POST has completed, check the Power and Alert LEDs to make sure that your Switch is operating correctly. Table 6 shows possible colors for these LEDs.
Table 6 Power and Alert LED colors
Power Green The Switch is powered-up and operating normally.
Off The Switch is not receiving power or there is a fault with the Power Supply Unit.
Alert Orange flashing The Switch is starting up or the Switch software is being upgraded.
Orange The Switch is reporting a fault (see Chapter 4, “Problem Solving”).
Off Normal operation.
If there is evidence of a problem, see “Solving Problems Indicated by LEDs” on page 52.
The Switch can power any IEEE 802.3af compliant device through rear panel ports 1, 2, 5 and 6. The Switch will support the following 3Com 802.3af equipment:
LED Color State

The Power-up Sequence 27
For the latest list of supported devices, go to the product page on the 3Com web site http://www.3com.com/.

For further information about Power Over Ethernet, refer to “Power Management and Control” in the Switch Implementation Guide supplied on the CD-ROM that accompanies your Switch. Power over Ethernet management is available using the web interface or the command line interface (CLI).
All of the RJ-45 ports on the Switch are Auto-MDIX, that is they have a cross-over capability. The port can automatically detect whether it needs to operate in MDI or MDIX mode. Therefore you can make a connection to a port with a straight-through (MDI) or a cross-over cable (MDIX).
The Auto-MDIX feature only operates when auto-negotiation is enabled.
If auto-negotiation is disabled, all the Switch ports are configured as MDIX (cross-over). If you want to make a connection to another MDIX port, you need a cross-over cable. Many ports on workstations and servers are configured as MDI (straight-through). If you want to make a connection to an MDI port, you need to use a standard straight-through cable. See Table 7.
3Com recommends that you use Category 5e twisted pair cable — the maximum segment length for this type of cable is 100 m (328 ft).
Table 7 Cables required to connect the Switch to other devices if auto-negotiation is disabled
Cross-over Cable Straight-through Cable
Switch to Hub (MDIX to MDIX) ✓ ✕
Switch to PC (NIC) (MDIX to MDI) ✕ ✓

to a grounded port before connecting network equipment. If you do not, the cable’s Electrostatic Discharge (ESD) may damage the Switch’s port.
You can create a grounded port by connecting all wires at one end of a UTP cable to an earth ground point, and the other end to a female RJ-45 connector located, for example, on a Switch rack or patch panel. The RJ-45 connector is now a grounded port.
SFP Operation The following section describes the use of an SFP transceiver in your Switch.
SFP transceivers are hot-insertable and hot-swappable. You can remove them from and insert them into any SFP port without having to power down the Switch.
The following list of approved SFP transceivers is correct at the time of publication.
To access the latest list of approved SFP transceivers for the Switch on the 3Com Corporation World Wide Web site, enter this URL into your internet browser:
To be recognized as valid, the SFP transceiver must have the following characteristics:
Use this transceiver to connect the Switch directly to a multimode fiber-optic cable with fiber LC connectors.
Use this transceiver to connect the Switch directly to a single-mode fiber-optic cable or to multimode fiber using a conditioned launch cable with fiber LC connectors.
SFP Operation 29

Use this transceiver to connect the Switch directly to a Category 5e twisted-pair cable with RJ-45 connectors.
If the SFP transceiver is faulty, it will not operate within the Switch. See “Solving Hardware Problems” on page 53.
Use of non-3Com SFPs is not recommended. If the SFP transceiver is invalid it will not be recognized by the Switch.
Use the following sequence of steps to activate the SFP ports:
1 Hold the transceiver so that the (1000BASE-TX) RJ-45 connector or (1000BASE-SX/LX) fiber connector is toward you and the product label is visible, as shown in Figure 6. Ensure the wire release lever is closed (in the upright position).
2 Gently slide the transceiver into the SFP port until it clicks into place.
3 Remove the plastic protective cover if fitted.
4 Connect the twisted-pair or fiber cable.


5 The 1000BASE-SX or 1000BASE-LX fiber transceiver connects to the network using a duplex LC connector. The 1000BASE-TX transceiver connects to the network using an RJ-45 connector. If you are using a fiber transceiver, attach a male duplex LC connector on the network cable into the duplex LC connector on the transceiver. If using a 1000BASE-TX transceiver, attach an RJ-45 connector on the network cable into the RJ-45 connector on the transceiver.
6 Connect the other end of the cable to a device fitted with an appropriate Gigabit Ethernet connection.
7 Check the Module Status LED on the front of the Switch to ensure that it is operating correctly. Refer to “LEDs” on page 14 for more information.
If you wish to remove a 3Com transceiver (it is not necessary to power-down your Switch):
1 Disconnect the cable from the transceiver.
2 Move the wire release lever downwards until it is pointing toward you.
3 Pull the wire release lever toward you to release the catch mechanism; the transceiver will then easily slide out.
SFP Operation 31

The above procedure will release a 3Com SFP transceiver. To release a transceiver from another manufacturer see the documentation supplied with your SFP transceiver.

Your Switch can operate in its default state, that is, you can install it and it will work straight away (plug-and-play). However, to make full use of the features offered by the Switch, and to change and monitor the way it works, you have to access the management software that resides on the Switch. This is known as managing the Switch.
Managing the Switch can help you to improve the efficiency of the Switch and therefore the overall performance of your network.
This chapter explains the initial set up of the Switch and the different methods of accessing the management software to manage a Switch. It covers the following topics:

This section gives an overview of what you need to do to get your Switch set up and ready for management when it is in its default state. The whole setup process is summarized in Figure 7. Detailed procedural steps are contained in the sections that follow. In brief, you need to:
Figure 7 Initial Switch Setup and Management Flow diagram

Plug and Play Setup Initial IP Information Setup Feature Management
Do you want to manually configure the IP information?
configured IP information? How do you want to connect to the Switch?
Connect to a rear network port and use the
How do you want to manage your Switch? See page 43

Setting Up Overview 35
IP Configuration You can use one of the following methods to allocate IP information to your Switch (essential if you wish to manage your Switch across the network).
You can choose to configure the IP information yourself. The Switch remembers the information that you enter until you change it again or set the configuration method to Automatic.
You should use the Manual IP configuration method if:
For most installations, 3Com recommends that you configure the Switch IP information manually. This makes management simpler and more reliable as it is not dependent on a DHCP server, and eliminates the risk of the IP address changing.
If you wish to manually enter IP information for your Switch, work through the “Manually Configuring IP Information” section on page 37.
By default the Switch tries to configure itself with IP information without requesting user intervention. It tries to obtain an IP address from a DHCP server on the network.
It may take up to 5 minutes for your Switch to obtain an IP address after it has been powered up.
When using automatic IP configuration it is useful if the Switch is issued the same IP address on each occasion, otherwise you will not know what the IP address is and it will be difficult to manage. Most DHCP servers

allow fixed IP addresses to be configured so that you know what IP address will be allocated to the Switch. Refer to the documentation that accompanies your DHCP server.
For a detailed description of how automatic IP configuration operates, please refer to the Implementation Guide on the CD-ROM that accompanies your Switch or on the 3Com Web site.
You should use the automatic IP configuration method if:
If you use the automatic IP configuration method, you need to discover the automatically allocated IP information before you can begin management. Work through the “Viewing Automatically Configured IP Information” section on page 40.
Once your Switch’s initial set up is complete you can set up your chosen management method as described in “Methods of Managing a Switch” on page 43.
For detailed information about the specific web interface operations and command line interface commands and problem solving, refer to the “Switch Management Interface Reference Guide” on the CD-ROM that is supplied with the Switch or on the 3Com Web site.

Manually Configuring IP Information 37
You can manually configure the Switch IP information in the following way:
To set up your Switch manually you can make a connection to the console port (this example describes a local connection to the console port, rather than a remote one via a modem). You can do this whilst the Switch is offline, that is, before you connect the Switch to a network, or whilst the Switch is online, that is, connected to a network.
Pre-requisites
You can find the pin-out diagram for this cable in Appendix B on page 69.

1 Connect the workstation to the console port using a standard null modem cable as shown in Figure 8.
Figure 8 Connecting a workstation to the Switch via the console port
Workstation (with terminal emulation
Connection Standard Null Modem Cable
To connect the cable:
a Attach the RJ-45 to RS-232 cable to the console port on the Switch. b Connect the other end of the cable to one of the serial ports (also
known as a COM port) on your workstation. c Tighten the retaining screws on the RS-232 connector to prevent it from being loosened.
2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.
Switch · software installed) · Console Port

Manually Configuring IP Information 39
You are now ready to manually set up the Switch with IP information using the command line interface.
1 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
If you have not logged onto the Switch before, you will be prompted to enter a new password. 3Com recommends that you change your password from its default blank setting.
2 At the login and password prompts, enter admin as your user name and enter your password at the password prompt (or just press Return if you have not yet set a password). If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 9.
Figure 9 Example top-level command line interface menu
bridge - Administer bridge-wide parameters feature - Administer system features gettingStarted - Basic device configuration logout - Logout of the Command Line Interface physicalInterface - Administer physical interfaces protocol - Administer protocols security - Administer security system - Administer system-level functions trafficManagement - Administer traffic management
Type ? for help. (1) Select menu option:
3 At the Select menu option prompt you can either:
or

4 Enter the IP address, subnet mask, and gateway IP address for the Switch. The screen displays a summary of the information entered.
If using the gettingStarted command you will then be prompted to enter system information, change passwords, and then given the option to carry out advanced configuration.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 43.
If you do not intend to use the command line interface via the console port to manage the Switch, you can disconnect the serial cable and close the terminal emulator software.
If you allow the Switch to automatically configure its own IP information you need to discover and view the IP information before you can begin to manage the Switch. You can discover the IP information in two ways:
You can use the 3Com Network Supervisor application provided on the CD-ROM that accompanies your Switch to discover the automatically allocated IP information.
1 Connect your Switch to the network.
2 Power-up the Switch and wait for two minutes.
3 Launch 3Com Network Supervisor and run the Auto-discovery wizard.
3Com Network Supervisor will auto-discover the new Switch and display the IP information that has been automatically allocated to the Switch.
Most DHCP servers allow static IP addresses to be configured so that you know what IP address the Switch will be given. Refer to the documentation that accompanies your DHCP server.

Viewing Automatically Configured IP Information 41
Alternatively, you can view the automatically configured IP information via the command line interface (CLI) through a connection to the console port. (This example describes a local connection to the console port, rather than a remote one via a modem.)
Pre-requisites
You can find the pin-out diagram for this cable in Appendix B on page 69.
1 Connect the workstation to the console port using the RJ-45 to RS-232 cable as shown in Figure 10.
Figure 10 Connecting a workstation to the Switch via the console port
Workstation (with terminal emulation
Connection Standard Null Modem Cable
To connect the cable:
a Attach the RJ-45 to RS-232 cable to the console port on the Switch. b Connect the other end of the cable to one of the serial ports (also
known as a COM port) on your workstation. c Tighten the retaining screws on the RS-232 connector to prevent it from being loosened.
Switch · software installed) · Console Port

2 Open your terminal emulation software and configure the COM port settings to which you have connected the cable. The settings should be set to match the default settings for the Switch, which are:
Refer to the documentation that accompanies the terminal emulation software for more information.
Set the baud rate on your management device to 19200 baud if you want to view all the system initialization messages.
You are now ready to view the automatically allocated IP information using the command line interface.
1 Connect your Switch to the network using an Ethernet cable. As soon as a network connection is made the Switch begins the automatic IP configuration process.
The automatic IP configuration process usually completes within one minute.
2 The command line interface login sequence begins as soon as the Switch detects a connection to its console port.
If the login prompt does not begin immediately, press Return a few times until it starts.
3 At the login and password prompts, enter admin as your user name and enter your password at the password prompt (or just press Return if you have not yet set a password). If you have logged on correctly, the top-level menu of the command line interface is displayed as shown in the example in Figure 11.

Methods of Managing a Switch 43
Figure 11 Example top-level command line interface menu
bridge - Administer bridge-wide parameters feature - Administer system features gettingStarted - Basic device configuration logout - Logout of the Command Line Interface physicalInterface - Administer physical interfaces protocol - Administer protocols security - Administer security system - Administer system-level functions trafficManagement - Administer traffic management
Type ? for help. (1) Select menu option:
4 At the Select menu option prompt enter the protocol ip interface summary command. A summary of the automatically allocated IP information is displayed. Make a note of the Network IP Address.
The initial set up of your Switch is now complete and the Switch is ready for you to set up your chosen management method. See “Methods of Managing a Switch” on page 43.
If you do not intend to use the command line interface via the console port to manage the Switch, you can logout, disconnect the serial cable and close the terminal emulator software.
Once you have completed the initial set up of your Switch, you can decide how you wish to manage the Switch. You can use one of the following methods:
Each Switch has a command line interface (CLI) that allows you to manage the Switch from a workstation, either locally via a console port connection (see Figure 12), or remotely over the network (see Figure 13).

Figure 12 CLI management via the console port

Figure 13 CLI management over the network

Refer to “Setting Up Command Line Interface Management” on page 45.
Each Switch has an internal set of web pages that allow you to manage the Switch using a Web browser remotely over an IP network (see Figure 14).
Figure 14 Web interface management over the network

Refer to “Setting Up Web Interface Management” on page 46.
SNMP Management You can manage a Switch using any network management workstation running the Simple Network Management Protocol (SNMP) as shown in Figure 15. For example, you can use the 3Com Network Supervisor software that is provided on the CD-ROM that accompanies your Switch.

Setting Up Command Line Interface Management 45
Figure 15 SNMP management over the network
Refer to “Setting Up SNMP Management” on page 47.
This section describes how you can set up command line interface management using a local console port connection or over the network.
To manage a Switch using the command line interface via the local console port connection:
1 Ensure you have connected your workstation to the console port correctly as described in “Connecting to the Console Port” on page 37.
2 Your Switch is now ready to continue being managed and/or configured through the CLI via its console port.
To manage a Switch using the command line interface over a network using Telnet:
1 Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 34.
2 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
3 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.

4 To open a Telnet session via the DOS prompt, enter the IP address of the Switch that you wish to manage in the following format:
If opening a Telnet session via third party software you will need to enter the IP address in the format suitable for that software.
5 At the login and password prompts, enter admin as your user name and enter your password at the password prompt (or just press Return if you have not yet set a password).
If the login prompt does not display immediately, press Return a few times until it starts.
6 If you have logged on correctly, the top-level menu of the command line interface for the Switch you wish to manage is displayed as shown in Figure 9 on page 39.
This section describes how you can set up web interface management over the network.
Pre-requisites ■ Ensure you have already set up the Switch with IP information as described in “Setting Up Overview” on page 34.
To display the web interface correctly, use one of the following Web browser and platform combinations:
Table 8 Supported Web Browsers and Platforms
XP
Netscape 7 ✓ ✓ ✓ ✓ ✕
Internet Explorer 5.5 and 6.0 ✓ ✓ ✓ ✓ ✕

Setting Up SNMP Management 47
For the browser to operate the web interface correctly, JavaScript™ and Cascading Style Sheets must be enabled on your browser. These features are enabled on a browser by default. You will only need to enable them if you have changed your browser settings.
To manage a Switch using the web interface over an IP network:
1 Check that you have the IP protocol correctly installed on your management workstation. You can check this by trying to browse the World Wide Web. If you can browse, the IP protocol is installed.
2 Check you can communicate with the Switch by entering a ping command at the DOS prompt in the following format:
If you get an error message, check that your IP information has been entered correctly and the Switch is powered up.
3 Open your web browser and enter the IP address of the Switch that you wish to manage in the URL locator, for example, in the following format:
(where xxx.xxx.xxx.xxx is the IP address of the Switch)
4 At the login and password prompts, enter admin as your user name and enter your password at the password prompt (or just press Return if you have not yet set a password).
5 Click on the Device View button to display the web management options.
Any network management application running the Simple Network Management Protocol (SNMP) can manage a Switch if:
You can use the 3Com Network Supervisor application that is provided on the CD-ROM that accompanies your Switch to provide SNMP management for your Switch. If you use 3Com Network Supervisor it

automatically loads the correct MIBs and necessary files onto your workstation.
Pre-requisites ■ Documentation supplied with the SNMP network management application software.
To manage your Switch using an SNMP network management application, you need to specify SNMP community strings for the users defined on the Switch. You can do this using the Web management interface — refer to the command line interface section of the “Switch Management Interface Reference Guide” for more information.
If you intend to manage the Switch using the web interface or the command line interface, or to change the default passwords, you need to log in with a valid user name and password. The Switch has two default user names, and each user name has a different password and level of access. These default users are listed in Table 9.
Table 9 Default Users
Default Password Access Level
monitor monitor monitor — the user can view all manageable parameters, but cannot change any manageable parameters
security — the user can access and change all manageable parameters
Use the admin default user name (no password) to login and carry out initial Switch setup.
You can change the default passwords using either:
User Name · admin (no password)

Default Users and Passwords 49
For more information about default users and passwords, refer to the “Switch Management Interface Reference Guide” on the Switch CD-ROM.


This chapter helps you to diagnose and solve problems you may have with the operation of your Switch. There is also an explanation of IP addressing.
The topics covered are:
If you experience a problem that is not listed here, it may be included in the Support section of the Switch Management Interface Reference Guide on the CD-ROM that accompanies your Switch.
For Technical Support information, see Appendix D.

Solving Problems Indicated by LEDs
If the LEDs on the Switch indicate a problem, refer to the list of suggested solutions below.
Check that the power cable is firmly connected to the Switch and to the supply outlet. If the connection is secure and there is still no power, you may have a faulty power cord or an internal fault. Check the power cord by:
Then contact your supplier for advice.
This indicates that a port has failed and has been automatically disabled. You can verify this by checking that the Port Status LED is flashing Green/Yellow. This could be due to loop back failure. If a port fails, the Switch passes its Power On Self Test and continues to operate normally.
On Powering up, the Alert LED flashes orange while the Switch is starting up. This is normal and does not indicate any of the above conditions.
The port has failed and has been automatically disabled. The Switch passes its Power On Self Test and continues to operate normally, even if one or more ports are disabled.
A link is connected and yet the Status LED for the port does not light
Check that:

Solving Hardware Problems 53
Auto-negotiation problems will occur with 10BASE-T, 100BASE-TX or 1000BASE-T where auto-negotiation is disabled and incorrect cables are being used (cross-over or straight).
Auto-negotiation problems will occur with fiber if:
A PoE device is connected and yet the PoE Status LED does not light
Refer to “A device is connected to the Switch but power is not being supplied” on page 53 for troubleshooting procedures.
In the rare event of your Switch unit experiencing a hardware failure, refer to the list of suggested solutions below.
A device is connected to the Switch but power is not being supplied
If power is not being supplied to a device connected to the Switch, you should do the following checks:
The Switch will only supply power through rear panel ports 1, 2, 5, and 6 to 802.3af compliant devices.
If the power budget has been exceeded, then by default, the powered device connected to the Power over Ethernet port with the lowest priority port will lose power. However, if all the devices connected to the Switch have equal priority levels, then the port with the highest number will lose power.
By default the Switch will allow a device to receive power as long as the Power over Ethernet power supply has 18 watts spare in its power budget. If this much power is not available the device will not be powered (unless it has a higher priority than existing powered ports) and a Power over Ethernet fault will be reported for that port. If

enough power subsequently becomes available the port will be powered.
If you experience communication problems with the Switch, ensure that:
The following is a brief overview of IP addressing, and how to obtain a registered IP address.
To be managed correctly, each device on your network (for example a Switch or Hub) must have a unique IP address. IP addresses have the format n.n.n.n where n is a decimal number between 0 and 255. An example IP address is 192.168.100.8.
The IP address is split into two parts:
The natural subnet mask for this example is 255.255.255.0.
If your network has a connection to the external IP network, that is, you access the Internet, you must apply for a registered IP address.
The IP registration system ensures that every IP address used is unique; if you do not have a registered IP address, you may be using an identical address to someone else and your network will not operate correctly.

Solving Software Upgrade Problems 55
The Internet Assigned Numbers Authority is the organization responsible for supplying registered IP addresses. The following contact information is correct at time of publication:
If your IP network is internal to your organization only, that is, you do not access the Internet, you may use any arbitrary IP address as long as it is not being used by another device on your network. 3Com suggests you use addresses in the range 192.168.0.0 to 192.168.255.255 with a subnet mask of 255.255.255.0.
These suggested IP addresses are part of a group of IP addresses that have been set aside specially for use ‘in house’ only.
You can upgrade the management software of the Switch by using the System > Control > Software Upgrade operation in the Web Interface, or the system control softwareUpgrade command in the command line interface. For details on these options, refer to the Management Interface Reference Guide supplied in HTML format on the CD-ROM that accompanies your Switch.
If you have problems with your software upgrade, refer to the Problem Solving section in the Management Interface Reference Guide.
The password recovery mechanism assumes that the Switch is located in a physically secure area, and access is restricted to legitimate network administrators. The first time the Switch is powered on, you will be prompted to set a password for administrator access. Record the password and store it in a safe place.
If you forget the password, follow this recovery procedure:


You must read the following safety information before carrying out any installation or removal of components, or any maintenance procedures on the Switch.

Power Cord Set — Japan

U.S.A. and Canada
Europe only: ■ The supply plug must comply with CEE 7/7 (“SCHUKO”).
Denmark ■ The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.
Switzerland ■ The supply plug must comply with SEV/ASE 1011.
United Kingdom only

Either shielded or unshielded data cables with shielded or unshielded jacks can be connected to these data sockets.
Class 1 LASER PRODUCT
Never look at the transmit laser through a magnifying device while it is powered on. Never look directly at the fiber TX port and fiber cable ends when they are powered on.

RJ-45 Pin Assignments
Pin assignments are identical for 10BASE-T and 100BASE-TX RJ-45 connectors.
Table 11 Pin assignments
Pin Number 10BASE-T/100BASE-TX 1000BASE-T
Ports configured as MDI
1 Transmit Data + Bidirectional Data A+
2 Transmit Data - Bidirectional Data A-
3 Receive Data + Bidirectional Data B+
4 Not assigned Bidirectional Data C+
5 Not assigned Bidirectional Data C-
6 Receive Data – Bidirectional Data B-
7 Not assigned Bidirectional Data D+
8 Not assigned Bidirectional Data D-
Table 12 Pin assignments
Pin Number 10BASE-T/100BASE-TX 1000BASE-T
Ports configured as MDIX
1 Receive Data + Bidirectional Data B+
2 Receive Data - Bidirectional Data B-
3 Transmit Data + Bidirectional Data A+
4 Not assigned Bidirectional Data D+
5 Not assigned Bidirectional Data D-
6 Transmit Data - Bidirectional Data A-
7 Not assigned Bidirectional Data C+
8 Not assigned Bidirectional Data C-

Physical Dimensions Height: 57.9 mm (2.3 in.) Width: 229 mm (9.0 in.) Depth: 185.4 mm (7.3 in.) Weight: 1.0 kg (approx)
Operating Temperature 0 ° to 50 °C (32 ° to 122 °F)
Storage Temperature –40 ° to +70 °C (-40 ° to 158 °F)
Operating Humidity 10–95% relative humidity, non-condensing
Standards EN60068 to 3Com schedule (Package testing: paras 2.1, 2.2, 2.30, and 2.32. Operational testing: paras 2.1, 2.2, 2.30 and 2.13).
Agency Certifications UL60950-1, EN60950-1, CSA 22.2 No. 60950-1, IEC 60950-1
Emissions CISPRR 22 Class A, EN55022 Class A, FCC Part 15 Subpart B Class A, ICES-003 Class A, AS/NZS 3548 Class A, EN61000-3-2, EN61000-3-3
Heat Dissipation 15 watts maximum (51 BTU/hour maximum)
Power Inlet 12V DC ± 5% provided by in-line adapter
AC Line Frequency 50/60 Hz
Input Voltage Options 100–240 VAC
Current Rating 3.5 A (amps) (maximum)

SNMP protocol (RFC 1157)
Protocols Used for Administration
Bridge MIB (RFC 1493)
RMON MIB (RFC 2819, Groups 1, 2, 3, 7, 8, 9)
ICMP (RFC 792)
RMON MIB II (RFC 2021)
TCP (RFC 793)
Remote Monitoring MIB (RFC 1757)
TFTP (RFC 783)
MAU MIB (RFC 2239)
DHCP (RFC 2131, RFC 2132, RFC 1534)
Standards Supported SNMP · Terminal Emulation · Telnet (RFC 854)

Warranty and other service benefits start from the date of purchase, so it is important to register your product quickly to ensure you get full use of the warranty and other service benefits available to you.
Warranty and other service benefits are enabled through product registration. Register your product at http://eSupport.3com.com/. 3Com eSupport services are based on accounts that you create or have authorization to access. First time users must apply for a user name and password that provides access to a number of eSupport features including Product Registration, Repair Services, and Service Request. If you have trouble registering your product, please contact 3Com Global Services for assistance.
To enhance response times or extend warranty benefits, contact 3Com or your authorized 3Com reseller. Value-added services like 3Com ExpressSM and GuardianSM can include 24x7 telephone technical support, software upgrades, onsite assistance or advance hardware replacement. Experienced engineers are available to manage your installation with minimal disruption to your network. Expert assessment and implementation services are offered to fill resource gaps and ensure the success of your networking projects. More information on 3Com maintenance and Professional Services is available at http://www.3com.com/
Contact your authorized 3Com reseller or 3Com for a complete list of the value-added services available in your area.

You will find support tools posted on the 3Com web site at http://www.3com.com/
3Com Knowledgebase helps you troubleshoot 3Com products. This query-based interactive tool is located at http://knowledgebase.3com.com and contains thousands of technical solutions written by 3Com support engineers.
Software Updates are the bug fix / maintenance releases for the version of software initially purchased with the product. In order to access these Software Updates you must first register your product on the 3Com web site at http://eSupport.3com.com/
First time users will need to apply for a user name and password. A link to software downloads can be found at http://eSupport.3com.com/, or under the Product Support heading at http://www.3com.com/
Software Upgrades are the software releases that follow the software version included with your original product. In order to access upgrades and related documentation you must first purchase a service contract from 3Com or your reseller.
To enable telephone support and other service benefits, you must first register your product at http://eSupport.3com.com/
Warranty and other service benefits start from the date of purchase, so it is important to register your product quickly to ensure you get full use of the warranty and other service benefits available to you.
When you contact 3Com for assistance, please have the following information ready:

To send a product directly to 3Com for repair, you must first obtain a return authorization number (RMA). Products sent to 3Com, without authorization numbers clearly marked on the outside of the package, will be returned to the sender unopened, at the sender’s expense. If your product is registered and under warranty, you can obtain an RMA number online at http://eSupport.3com.com/. First time users will need to apply for a user name and password.
Contact Us 3Com offers telephone, e-mail and internet access to technical support and repair services. To access these services for your region, use the appropriate telephone number, URL or e-mail address from the list below.
Telephone numbers are correct at the time of publication. Find a current directory of contact information posted on the 3Com web site at http://csoweb4.3com.com/contactus/
Country Telephone Number Country Telephone Number
Asia, Pacific Rim Telephone Technical Support and Repair
Australia Hong Kong India
1 800 678 515 800 933 486 +61 2 9424 5179 or 000800 650 1111 001 803 61009 00531 616 439 or 03 3507 5984 1800 801 777 0800 446 398 +61 2 9937 5083
1235 61 266 2602 or 1800 1 888 9469 800 810 3033 800 6161 463 080 333 3308 00801 611 261 001 800 611 2000
P.R. of China Singapore S. Korea Taiwan Thailand
Malaysia New Zealand Pakistan
You can also obtain support in this region using the following e-mail: apr_technical_support@3com.com
Or request a repair authorization number (RMA) by fax using this number: + 65 543 6348
Europe, Middle East, and Africa Telephone Technical Support and Repair
From anywhere in these regions, call:
From the following countries, you may use the numbers shown:

Country Telephone Number Country Telephone Number
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy
01 7956 7124 070 700 770 7010 7289 01080 2783 0825 809 622 01805 404 747 06800 12813 1407 3387 1800 945 3794 199 161346
Luxembourg Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
342 0808128 0900 777 7737 815 33 047 00800 441 1357 707 200 123 0800 995 014 9 021 60455 07711 14453 08488 50112 0870 909 3266
You can also obtain support in this region using the following URL: http://emea.3com.com/support/email.html
Latin America Telephone Technical Support and Repair
Antigua Argentina Aruba Bahamas Barbados Belize Bermuda Bonaire Brazil Cayman Chile Colombia Costa Rica Curacao Ecuador Dominican Republic
1 800 988 2112 0 810 444 3COM 1 800 998 2112 1 800 998 2112 1 800 998 2112 52 5 201 0010 1 800 998 2112 1 800 998 2112 0800 13 3COM 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112
Guatemala Haiti Honduras Jamaica Martinique Mexico Nicaragua Panama Paraguay Peru Puerto Rico Salvador Trinidad and Tobago Uruguay Venezuela Virgin Islands
AT&T +800 998 2112 57 1 657 0888 AT&T +800 998 2112 1 800 998 2112 571 657 0888 01 800 849CARE AT&T +800 998 2112 AT&T +800 998 2112 54 11 4894 1888 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 1 800 998 2112 AT&T +800 998 2112 AT&T +800 998 2112 57 1 657 0888
You can also obtain support in this region using the following:
English speakers in Latin America should send e-mail to: lat_support_anc@3com.com
US and Canada Telephone Technical Support and Repair
1 800 876 3266


FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference to radio communications, in which case the user will be required to correct the interference at their own expense.
INFORMATION TO THE USER If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the Federal Communications Commission helpful:
How to Identify and Resolve Radio-TV Interference Problems
This booklet is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4.
In order to meet FCC emissions limits, this equipment must be used only with cables which comply with IEEE 802.3.
CSA STATEMENT This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
CE STATEMENT (EUROPE) This product complies with the European Low Voltage Directive 73/23/EEC and EMC Directive 89/336/EEC as amended by European Directive 93/68/EEC.
You must only insert a 3Com approved SFP transceiver into the Switch. These are listed in the “Approved SFP Transceivers” section of the Getting Started Guide.



Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.