0908 Model # AC-G0002 3500 Surge Watts / 3000 Running Watts PORTABLE GENERATOR INSTRUCTION MANUAL Thank you for purchasing this high quality ACDelco Model AC -G0002 3500 Surge Watts / 3000 Running Watts Portable Generator.
ACDelco Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator FEATURES: • 3500 Surge Output • 3000 Running Watts • 120/240 Volt Operation • 6.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 3 TABLE OF CONTENTS RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS .................................................................................................... 4 IMPORTANT SAFETY INSTRUCTIONS .
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment.
Notice Regarding Emissions: Engines certified to comply with California and U.S. EPA emissi on regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission c ontrol systems: Three-Way Catalyst (TWC) (if equipped), and E ngine Modifications (EM).
Powerful Voltage: This generator produces powerful voltage, which can result in electrocution. • ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). • Only electrical devices should be plugged into this generat or, either directly or with an extension cord.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 7.
In addition to the previously described safety information, fam iliarize yourself with all safety and hazard placards on this ge nerator. – Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Port.
PACKAGE CONTENTS The following items are supplied with this ACDelco Model AC -G0002 3500 Surge Watts / 3000 Running Watts Portable Generator. Ver ify that all items are included. STOP! If there are missing items, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service.
GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator. (1) 120/240 Volt AC Outlet - Used for connecting electrical devices that run on 120 and/or 240 Volt, 60 Hz, single phase, AC current. (2) Ground Terminal - Used for connecting grounding wires to properly ground this generator.
PREPARING THE GENERATOR FOR USE Using this Generator for the First-Time STOP! The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life.
Step 2 - Add Gasoline Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns. • Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, el ectric appliances, power tools, etc.
Step 3 - Ground the Generator Failure to properly ground this generator can result in electrocution. Ground this generator by tightening the grounding nut against a groundi ng wire as illustrated in Figure 3. A No. 12 AWG (Americ an Wire Gauge) stranded copper wire is generally an acceptable grounding wire.
Step 2 - Verify Gas Level Before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the top o f this generator, indicates the gas level currently in the fuel tank.
6. Slowly pull on the recoil starter handle, shown in Figure 6, until a slight resistance is felt. Then pull briskly to start t he engine. Gently return the cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.
The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself. To calculate the total wattage requirement of the .
Connect only electrical devices that are in good working order. Faulty devices or power cords present the risk of electrical sh ock. Immediately turn off and disconnect any d evice that commences to operate abnormally, sl uggish or abruptly stops.
SOME NOTES ABOUT POWER CORDS Long or thin cords can require more wattage from a generator to power an electrical device. Figure 9 shows the recommended cord s according to the power requirement of the electrical device.
STOPPING THE GENERATOR To stop this generator: 1. Turn off all connected electrical devices and then unplug them. 2. Switch the circuit breaker to the “off” position. 3. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator.
Cleaning the Generator Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, vacuum and/or pressurized air. Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion.
NOTE: Never dispose of used motor oil in the trash, down a drain or on the ground. Put oil in a sealed container and contact yo ur local recycling center or auto garage to arrange oil disposal. To add oil to the engine crankcase: 1. Confirm that this generator is on a level surface.
Figure 14 - Removing the Air Filter Casing. Fuel Filter Cup Cleaning The fuel filter cup is a small well underneath the fuel valve whic h helps trap dirt and water that may be in the fuel tank befo re entering the engine. To clean the fuel filter cup: 1.
Model AC-G0002 Spark Plug Type F6TC Model AC-G0002 Spark Plug Gap (in/mm) 0.028-0.031/0.7-0.8 To inspect the spark plug: 1. Remove the spark plug by pulling on the spark plug cap. 2. Unscrew the spark plug from this generator by using the included spark plug wrench as illustrated in Figure 16.
STORAGE/TRANSPORT PROCEDURES Never p lace an y t yp e of stora g e cover on this g enerator while it is still hot. When transporting or storing this generator for extended time: • Allow generator to fully cool before moving it. A hot engi ne and exhaust system can burn you and ignite some materials.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 25 TROUBLESHOOTING IMPORTANT: If trouble persists, call our customer help line at 1-866-460-9436, M onday - Friday, 8 AM - 4 PM Central Time. Symptom Cause Solution Engine switch is set to "off.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 26 SPECIFICATIONS ACDelco Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator Generator Type Brush, Revolv.
Model AC-G0002 3500 EXPLODED VIEW AND PARTS LIST Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 27.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 28 Model AC-G0002 3500 PARTS LIST Item Part Qty Description Item Part Qty Description 1 168F-2BV Gasoline engine 39 31933 1 Bo.
MODEL AC-G0002 3500 SURGE WATTS / 3000 RUNNING WATTS PORTABLE GENERATOR WIRING DIAGRAM Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 29.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 30 NOTES:.
WARRANTY LIMITED WARRANTY for ACDelco Generators from New Buffalo Corporation. Remember to save your receipt and to accurately fill out and ma il your product registration card.
PORTABILITY KIT INSTALLATION The manufacturer recommends when using your ACDelco generator for recreational or utility functions that you properly install t he Portability Kit included with your generator purchase. All ACDelco generator models include a Portability Kit for optional installation.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 33.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 34.
Model AC-G0002 3500 Surge Wa tts / 3000 Running Watts Portable Gen erator 35 (AC-G0002-0908).
An important point after buying a device ACDelco AC-G0002 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought ACDelco AC-G0002 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data ACDelco AC-G0002 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, ACDelco AC-G0002 you will learn all the available features of the product, as well as information on its operation. The information that you get ACDelco AC-G0002 will certainly help you make a decision on the purchase.
If you already are a holder of ACDelco AC-G0002, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime ACDelco AC-G0002.
However, one of the most important roles played by the user manual is to help in solving problems with ACDelco AC-G0002. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device ACDelco AC-G0002 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center