Protected MasterColor® Metal Halide 150 Watt ED-17P 3K (Clear) Lamp Featuring ALTO® Lamp Technology
Ordering Code MHC150/U/MP/3K/ALTO ANSI Designation M142/M102/O Product Number 134635 Description MasterColor Metal Halide Package Quantity 12
5 7 / 16 "
Bulb Size ED-17P Bulb Finish Clear Base Medium Screw Max. Overall Length (MOL) 5 7/16'' (138mm) Light Center Length (LCL) 3 7/16'' (87mm) Arc Length 0.79'' (20mm) Arc Tube Material Poly Crystalline Alumina Max. Permissible Bulb Temp. 350˚C (662˚F) Max. Permissible Base Temp. 190˚C (374˚F) Max. Bulb to Base Eccentricity 3º Max. Arc Tube to Base Eccentricity 3º
◗ Operating Characteristics (Photometric)
MasterColor® Spectral Power Distribution—3K Types
Rated Initial Lumens (1) 12,900 Mean Lumens,Approximate (2) 9545 Rated Average Life, Hours 10,000 Correlated Color Temperature (CCT) (2) 3000 K CIE Chromaticity Approximate (2) x-.433, y-.398 Color Rendering Index (CRI) 85 Efficacy (lpw) 86
◗ Operating Position
400 450 500 550 600 650 700
Average Lumen Maintenance Curve, MHC150/U/MP/3K

Philips Lighting Company 200 Franklin Square Drive ■P.O. Box 6800 Somerset, NJ 08875-6800 1-800-555-0050 www.lighting.philips.com/nam A Division of Philips Electronics North America Corporation
Philips Lighting 281 Hillmount Road Markham, Ontario Canada L6C 2S3 1-800-555-0050 www.lighting.philips.com/nam A Division of Philips Electronics Ltd.
Protected MasterColor® Metal Halide 150 Watt ED-17P 3K (Clear) Lamp Featuring ALTO® Lamp Technology Electrical Data (Subject to change without notice)
Lamp Watts (Nominal) 150 Lamp Operating Voltage (rms) (Nominal) (2) 95 Initial Lamp Voltage Range (rms) (3) 85-105 Lamp Operating Current (Amps) (rms) (Nominal) 1.5 Lamp Current Crest Factor (Maximum) 1.8 Warm-up Time to 80% of Output 2 Minutes Re-strike Time for Hot Lamp 4-8 Minutes Ballast Type ANSI M142/M102/O Ballast Open Circuit Voltage (Minimum) 382 RMS, 540 Peak Pulse Peak Volts 3300 Min.,4000 Max. Pulse Width @ 90% Peak 2 Micro Second Minimum Pulse Repetition Rate (Minimum) 2 per Half Cycle Minimum Operating Temperature -30º C (-22º F)
Warnings, Cautions and Operating Instructions “WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.” This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)
Lamp Operating Instructions: 1) RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture. 2) Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards. 3) Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.
If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radia- tion. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.
A. Operate lamp only within specified limits of operation. B. For total supply load refer to ballast manufacturers electrical data. 4) Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage. 5) If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass. 6) Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat. 7) Time should be allowed for lamps to stabilize in color when turned on for the first time. This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock, and color appearance may vary between individual lamps. 8) Lamps may require 4 to 8 minutes to re-light if there is a power interruption. 9) Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.
WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.
These lamps are designed to retain all the glass particles should an arc tube rupture occur. The following operating instructions are recommended to minimize these occurrences.
RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.
This lamp contains an arc tube with a filling gas containing Kr-85 and is distributed by Philips Lighting Company, a division of Philips Electronics North America Corporation, Somerset, New Jersey 08875-6800.
Updated 9/03 MHC150/U/MP/3K/ALTO