EN
Perlick logo
Official user manual

Perlick Z2148

2 pages·72 KB·Beverage Dispenser·PDF·ENDEFRITNLJA
Perlick Z2148
Table of Contents 14 sections Troubleshooting · OPERATING INSTRUCTIONS SMART COUPLER with Empty Keg Sensor · Part No. I 26000F · IMPORTANT! · … ShowHide
Page 1 of the Perlick Z2148 user manual — Retrofitting Single Valve Couplers
Page 1 · click to enlarge
Page 1

Troubleshooting

OPERATING INSTRUCTIONS SMART COUPLER with Empty Keg Sensor

Problem: Beer flow is slower with Smart Coupler than with standard Perlick coupler.

Part No. I 26000F

Perlick Z2148 — Part No. I 26000F diagram (page 1)
Fig. 1 · Part No. I 26000F

Probable Cause: Beer Flow Control Handle is in CLEAN position. Solution: Slowly turn Beer Flow Control Handle to ON position.

Problem: Beer does not flow after keg is tapped.

The Smart Coupler* combines a standard Perlick single-valve keg coupler with a specially-designed keg sensor that eliminates the line loss that normally follows every empty keg. Fresh kegs can be drawn off immediately. The beer lines are always full of beer.

Probable Cause: Smart Coupler has locked up. Solution: First, turn Beer Flow Control Handle to OFF position then turn Beer Flow Control Handle to CLEAN position. Wait five seconds then turn Beer Flow Control Handle to ON position.

Probable Cause: Beer Flow Control Handle is OFF. Solution: Turn Beer Flow Control Handle to CLEAN position. Wait five seconds then turn Beer Flow Control Handle to ON position.

  • Saves time
  • Reduces beer waste
  • Increases beer profits
  • Reduces aggravation

No. 26000F Smart Coupler with Empty Keg Sensor

Probable Cause: Probe or Smart Coupler is dirty. Solution: Clean Smart Coupler.

IMPORTANT!

To ensure your complete satisfaction, please read these instructions before using Perlick’s Smart Coupler.

Probable Cause: Out of gas. Solution: Reestablish gas flow.

Retrofitting Single Valve Couplers

Problem: Excessive foam.

Perlick single valve keg couplers can be retrofitted to function as Smart Couplers. Simply replace the probe with Perlick’s No. 40125 empty keg sensor.

Probable Cause: Beer temperature too high. Excessive beer flow rate. Beer is over-carbonated Solution: These problems are not caused by the Smart Coupler. Follow established procedures to correct the problem.

1. Remove probe washer from bottom of probe.
2. Remove retaining screw and yoke assembly.
3. Lift probe out of body.
4. Install Perlick’s empty keg sensor. When replacing probe washer make sure the surface marked “ up ” faces the probe washer.

Perlick’s Empty Keg Sensor

No. 40125 (Probe Washer Not Included)

  • 8300 West Good Hope Road
  • Milwaukee, WI 53223
  • Phone 414-353-7060 Fax 414-353-7069Toll Free 800-558-5592
  • E-Mail: Perlick@<a href="http://Perlick.com" rel="nofollow noopener" target="_blank">Perlick.com</a>
  • <a href="http://www.Perlick.com" rel="nofollow noopener" target="_blank">www.Perlick.com</a>

* U.S. Patent #5,630,411 Form Z2148

04.06.04

Page 2 of the Perlick Z2148 user manual — Warranty
Page 2 · click to enlarge
Page 2

TAPPING and CLEANING PROCEDURES REPLACEMENT PARTS

Beer Flow Control

Filling the Lines the First Time

Handle Operating

1. Turn Beer Flow Control Handle OFF. (See Fig. 1).

Positions

2. Tap fresh keg.
3. Turn Beer Flow Control Handle to CLEAN . (See Fig. 3).
4. Open the beer faucet. When solid beer appears, close the faucet. The line is full.
5. Turn Beer Flow Control Handle ON . (See Fig.2). The line is full and ready for service. When Tapping Fresh Kegs
1. Remove coupler from empty keg .

OFF

ON

2. Turn Beer Flow Control Handle OFF. (See Fig. 1).
2. Tap fresh keg in normal manner.
3. Turn Beer Flow Control Handle to CLEAN . position. (See Fig. 3). Wait for five seconds then turn to ON position. (See Fig. 2). To Restart System If beer does not flow, first turn the Flow Control Handle to OFF . (See Fig. 1). Then turn Handle to the CLEAN position. (See Fig. 3). Wait for five seconds then turn the Handle to ON position. (See Fig. 2).

Item Part No Description

1. 40125 Empty keg Sensor 2 43001A Std. Yoke Assy. 3 2026 Hex Nut 4 2068-1 Tailpiece 5 157R2P Washer 6 23682-2P Check Valve 7 31084-1 Retaining Screw 8 31089-2P “O” Ring (3 per assy.) 9 43061 Body w/relief valve 10 31088-2P Bottom Seal Washer 11 31087-2P Probe Washer

To Clean

Fig. 3 CLEAN

1. Untap Keg in usual manner.

No. 43657 No. 43681 Single Adapter Dual Adapter

2. Turn Beer Flow Control Handle OFF (See Fig. 1).
Perlick Z2148 — To Clean diagram (page 2)
Fig. 2 · To Clean
3. Attach cleaning adapter. Use Perlick’s single cleaning adapter, No. 43657, if cleaning from faucet to keg. If two or more lines are cleaned, use Perlick’s dual cleaning adapter, No. 43681.

Warranty

4. Turn Beer Flow Control Handle to CLEAN and clean as usual. (See Fig. 3).

Perlick products are fully guaranteed against defects in both material and workmanship for a period of one year from date of sale. Defective parts will be replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We are not responsible for parts damaged by alteration, unauthorized service, accident or abuse. All costs incident to replacement to include freight, labor and/or loss of sales are incidental to this warranty and must be borne by the user.

5. After flushing, turn Beer Flow Control Handle OFF and retap keg. (See Fig. 1).
6. To restore service, see above instructions.

45° · Cleaning Adapters

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Perlick Z2148

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Perlick Z2148

Be the first to ask — other owners or our team will answer.

Original document

Perlick Z2148 manual PDF

2 pages·72 KB·Beverage Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…