Preparing the Cabinet for Use – Concessionaire Dispensers

Parts List Plumbing ■ Faucet Standard. Connect drain tube from drainer into dump tank. ■ Faucet Head Assembly Electrical ■ Caster Set. ■ Black Connector Hose 3⁄16” x 3’. The cabinet must be connected to a separately ■ 5⁄16” Air Hose. fused power source (see electrical specification ■ Spanner Wrench. plate) and grounded in accordance with National ■ Bag of Miscellaneous Parts. and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other Tools Required power source than that listed on the Electrical Specification plate. ■ #2 Phillips Screwdriver. ■ Spanner Wrench (included). Installing the Faucet and ■ #10 Crescent Wrench. Dispensing Head ■ 9/16” Allen Wrench. ■ 3/8” Nut driver. Before you begin: Wash dispensing head and fau- ■ Power driver. cet. Flush beer, dispensing head and faucet lines with fresh water. Uncrating and Inspection ■ Apply RTV around the base of the dispensing Remove all crating material before operating. head to seal it to the top. Align the dispensing Carefully inspect cabinet for hidden damage. If head over the five holes on the cabinet top damage is discovered, file your claim immediately and use the five stainless steel #10-32 x 13⁄4” with the transportation company. Perlick is Phillips pan head stainless steel machine not responsible for damage in transit. screws to secure standard to cabinet top. Wipe off excess RTV to complete the seal. Installing Casters ■ Attach faucet to standard using spanner wrench to tighten coupling. Attach faucet IMPORTANT: Attach casters to the cabinet bothandle to faucet. tom so that caster is centered over cabinet seam. ■ Insert flexible plastic air hose six to seven Use supplied 1/4”- 20 x 3/4” hex head self-tapping inches into bottom of faucet standard. machine screws. Secure hose with tie wrap (supplied). Se CASTER MOUNTING PLATE MUST STRADDLE SEAM COMPRESSOR HOUSING SCREWS DRY STORAGE COMPARTMENT CENTER CASTERS REQUIRED ON DC4KP (4 KEG CONCESSIONAIRE) CASTER MOUNTING PLATE MUST STRADDLE SEAMCABINET DRAIN TuBE ACCESS FROM HOLE DRAINER DuMP TANK CO2 TANK ACCESS DOOR CHAIN FOR SECuRING CO2 TANK REMOVABLE DuMP TANK CO2 TANK (Must Be Secured When Moving Cabinet)

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 4 of the Perlick DC84S user manual — Connecting the Keg Coupler (when Supplied by Perlick)
Page 4 · click to enlarge
Page 4

Installation and Tapping – Concessionaire Dispensers

Connecting the Keg Coupler (when Supplied by Perlick)

Tapping a Single Valve Keg (Sankey)

  • Place one brown leather washer into black beer line connector hose on hex nut side. Screw connector to stainless steel beverage line on faucet standard. Tighten with a wrench, but do not over tighten.
  • Make sure lever handle on the keg coupler is in the UP (untapped) position. Place one brown leather washer into wing nut end of black beer line connector hose and thread onto top of keg coupler. Hand tighten.
  • Place clamp on one end of red air line. Push end over air valve located inside cabinet. Tighten clamp with screwdriver. Turn shut-off valve to OFF (horizontal) position.
  • Place clamp on the other end of red air line and push over tailpiece on coupler. Tighten clamp with screwdriver.
Perlick DC84S — Connecting the Keg Coupler (when Supplied by Perlick) diagram (page 4)
Fig. 1 · Connecting the Keg Coupler (when Supplied by Perlick…
Perlick DC84S — Connecting the Keg Coupler (when Supplied by Perlick) diagram (page 4)
Fig. 2 · Connecting the Keg Coupler (when Supplied by Perlick…
Perlick DC84S — Connecting the Keg Coupler (when Supplied by Perlick) diagram (page 4)
Fig. 3 · Connecting the Keg Coupler (when Supplied by Perlick…
  • Be sure beer faucet is in closed position.
  • Align keg lugs with lug openings on bottom of coupler.
  • T urn clockwise 1 ⁄ 4 turn. Pull handle out and down. Keg is now tapped.
  • Open shut-off valve on air divider located inside of the cabinet.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 5 of the Perlick DC84S user manual — CO 2 Leak Test
Page 5 · click to enlarge
Page 5

Installation and Tapping – Concessionaire Dispensers

Connecting the Regulator to the CO 2 Cylinder

Replacing CO 2 Gas Cylinder

  • Turn CO 2 hand valve clockwise until seated and close shut-off valve on regulator.
  • Unscrew regulator from cylinder fitting.
  • Replace carbonic washer (Part No. 157F2P), if needed and reattach regulator to filled cylinder.
  • Turn CO 2 hand valve counterclockwise until fully open. Turn regulator shut-off valve to open position.
  • Adjust CO 2 gas flow as required, turning clock wise for higher pressure.
  • Remove blue plug from regulator fitting. (Note: Do not remove the carbonic washer).
  • Screw regulator onto gas cylinder valve. Tighten with wrench until vertically straight. Be sure that shut-off valve ( black lever ) on regulator is in the OFF ( horizontal ) position.
  • Place a screw clamp over end of red air line and push onto regulator tailpiece. Tighten clamp with a screwdriver.

REGULATOR FITTING

Proper CO 2 Handling

CO2 PRESSURE GAUGE

Perlick DC84S — REGULATOR FITTING diagram (page 5)
Fig. 4
  • always ...
  • Connect a regulator (reducing valve) to CO 2 cylinder.
  • Secure cylinder in upright position whether in storage or in use.
  • Keep cylinder away from heat. Rupture disc vents at 122° F. maximum.
  • Ventilate room after high pressure gas leakage.
  • Check the last DOT test date on cylinder neck before filling. If more than five years old, the cylinder must be retested to DOT specifications.
  • Be sure CO 2 cylinder outlet fitting is free of dust or dirt before attaching regulator.
  • Store CO 2 cylinder and regulator assembly upright.
  • Allow only properly trained and experienced personnel to handle high pressure gas.

CO2 GAS DRUM

SHUT-OFF VALVE (BLACK LEVER IN CLOSED POSITION)

Adjusting the CO 2 Gas Flow

  • Turn regulator adjusting screw counterclockwise until it turns freely.
  • Turn hand valve counterclockwise on CO 2 cylinder to the fully open position.
  • Turn regulator adjusting screw clockwise until desired pressure is reached (approximately 12-15 lbs.). Tighten stop nut on adjusting screw.
  • Open shut-off valve on bottom of regulator.
  • never ...
  • Connect cylinder directly to a keg without a regulator (reducing valve).
  • Drop or throw regulator or CO 2 cylinder.
  • Transport CO 2 cylinder in a closed vehicle.
  • Apply oil to a regulator.
  • Shut off CO 2 cylinder when not in use. You will not save gas by doing so!
  • Allow untrained, inexperienced personnel to handle high pressure gas. Failure to heed this warning could result in personal injury or death.

CO 2 Leak Test

Dilute a small amount of liquid dishwashing soap and rub the soapy mixture around each connec- tion. If bubbles appear, tighten connection.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 6 of the Perlick DC84S user manual — Refrigeration and Temperature Control
Page 6 · click to enlarge
Page 6

Draft Beer Information – Concessionaire Dispensers

Temperature

One of the most common causes of dispensing problems is improper temperature. Draft beer should be stored at a temperature between 32° and 38°. At warmer temperatures, beer will foam.

At temperatures lower than 30° F., beer will freeze. When beer freezes, the alcohol in the beer may separate and cause the beer to be cloudy with an “off” taste.

Refrigeration and Temperature Control

Adjusting the Temperature

The Concessionaire’s are equipped with a heavy- duty refrigeration system that is factory set to maintain a product storage temperature of approxi- mately 38° F.

  • The temperature control is inside the cabinet on the right-hand side of the evaporator fan panel assembly. You will need a screwdriver to turn the adjusting screw. Make small adjustments until the desired temperature is achieved.
  • Colder Temperatures: Turn the adjusting screw clockwise (to the right).
  • Warmer Temperatures: Turn the adjusting screw counterclockwise (to the left).

The condenser fan motor turns off and on with the condensing unit. The evaporator fan motor runs continuously. The fan motors are lifetime lubricated and will require no oiling.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 7 of the Perlick DC84S user manual — Cleaning the Condenser
Page 7 · click to enlarge
Page 7

Cleaning the Beer System – Concessionaire Dispensers

  • Beer Stone: All beer contains calcium which is present from the grains used in the brewing process. it is an important natural material in draft systems in that as it oxidizes it coats the internal parts of the beer lines and equipment. This thin coat of beer stone helps prevent the beer from picking up strong metallic or plastic flavors as it flows through the system. The beer stone will continue to build if the system is not cleaned properly or regularly and can cause drawing problems if it begins to flake off. Beer stone is present if one can see a brownish color on the faucet or inner wall of the beer line, or tobaccolike flakes in the beer.

The entire beer system, to include the faucet, flexible beer line and tapping devices must be cleaned at regular intervals. We recommend flushing the entire system with fresh water immediately after a keg has been emptied. Once each month the system should be cleaned chemically.

It is recommended that you purchase Perlick’s Pump Type Cleaning Kit. It is equipped with an adapter that attaches directly to the faucet shank, jar with pump, cleaning solution, faucet brush and spanner wrench.

Cleaning the draft beer system will help to eliminate the buildup of the following materials:

  • Bacteria: Beer is an excellent food for bacteria (none of which is harmful). Proper conditions may begin the growth of bacteria in draft beer and on the beer faucet. By regular cleaning, we prevent this bacterial buildup and maintain the quality of the draft beer. Greenish or yellowish colored material on the faucet may indicate bacterial growth.

Cleaning the Cabinet

Use a mild detergent and water to clean the inside and outside of the cabinet. Dry thoroughly. Never use a scouring pad or abrasive cleanser. Note: An industrial strength, commercial cleaner can be used to clean the outside of painted cabinets.

  • Yeast: All domestic draft beers contain a small amount of yeast which remains in the beer from the fermentation process. When the temperature of draft beer exceeds 50° a process of secondary fermentation may take place. The beer faucet may exhibit a white colored substance (yeast build up) if not cleaned on a regular basis.

Cleaning the Condenser

Use a long handled, stiff brush to clean the dirt from the front surface of the condenser. Keeping the condenser free from dust and dirt will ensure efficient operation.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 8 of the Perlick DC84S user manual — Pouring a Perfect Glass of Beer – Concessionaire Dispensers
Page 8 · click to enlarge
Page 8

Pouring a Perfect Glass of Beer – Concessionaire Dispensers

Perlick DC84S — Pouring a Perfect Glass of Beer – Concessionaire Dispensers diagram (page 8)
Fig. 5 · Pouring a Perfect Glass of Beer – Concessionaire Dis…

Start with a clean glass. Place the glass at a 45° angle, one inch below faucet. Do not let the glass touch the faucet. Open the faucet all the way.

reached half full, gradually bring the glass to the upright

Perlick DC84S — Pouring a Perfect Glass of Beer – Concessionaire Dispensers diagram (page 8)
Fig. 6 · Pouring a Perfect Glass of Beer – Concessionaire Dis…

Let the remaining beer run straight down the middle of the glass. This ensures proper release of CO2 by producing a 3⁄4” to 1” foam head.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 9 of the Perlick DC84S user manual — Beer and CO 2 Facts
Page 9 · click to enlarge
Page 9

Trouble Shooting – Concessionaire Dispensers

Beer Service Problems

  • Cloudy Beer: Beer in glass appears hazy, not clear.
  • Wild Beer : Dispensed beer has either too much foam or is all foam.

C auses :

  • Dirty glass.
  • Dirty faucet or beer line.
  • Frozen or nearly frozen beer.
  • Old beer.
  • Beer that has not been refrigerated for a long period of time.
  • C auses :
  • Beer has been dispensed improperly. Solution: See pouring instructions on page 8.
  • Regulator pressure is set too high.
  • Warm keg temperature. Solution: Keg must be colder than 40°. Target temperature is between 36° and 38° F.
  • Cabinet door is opened and closed frequently and temperature is warmer than 38° F. Solution: Adjust temperature to between 36° and 38° F.
  • Kinks, dents or obstructions in the line.
  • Using oddly shaped glasses. Frosted, waxed or styrofoam containers may cause foaming.
  • Dispenser has been turned off for a long period of time.
  • Faucet is bad, dirty or in a worn condition.
  • Regulator malfunction.

Beer and CO 2 Facts

Keg SizeNo. of GallonsNo. of Oz.No. of CasesNo. of 12Oz. ServingsFull Keg Weight Quarter73⁄49923.44510587 lbs. Half151⁄21,9846.889210161 lbs.
  • Beer foam is 25% liquid beer and 75% CO 2 gas. Don’t waste it!
  • Most people prefer beer stored at 38° F.
  • Beer lines and faucets require regular cleaning (see cleaning instructions on page 7).
  • A fully-charged 4.2 lb. CO2 cylinder will dispense approximately 5 1 ⁄ 2 to 6 1 ⁄ 2 half barrels.
  • CO 2 gas gives beer its sparkling effervescence. It also gives beer its creamy head of foam.
  • Flat Beer: Foamy head disappears quickly; beer lacks brewery fresh flavor.
  • C auses :
  • Dirty glassware.
  • CO 2 pressure is too low, due to leak or pressure setting.
  • CO 2 is turned off at night.
  • Cooler is too cold.
  • CO 2 leak or defective (sticking) check valve.
  • Sluggish CO 2 regulator.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 10 of the Perlick DC84S user manual — Replacement Parts – Concessionaire Dispensers
Page 10 · click to enlarge
Page 10

Replacement Parts – Concessionaire Dispensers

MODEL NOS.DC72SDC84SDC96S Condensing Units Condensing unit 115 volt, 60 hz.C22647C22646C22646 Condensing unit515301063515301062515301062 Compressor513200314513200003513200003 Fan motor assembly515315009515315009515315009 Condenser coil153520191535201915352019 Terminal board519100088519100088519100088 Overload protectorUS-PB10HBX1US-PB12HBX1US-PB12HBX1 RelayUS-PB10HBX1US-PB12HBX1US-PB12HBX1 Capacitor US-PB10HBX1 US-PB12HBX1 US-PB12HBX1 Evaproator Assembly Self Contained complete 65555-1 65555-2 65555-2 Evaporator coil C17511-1EP C17511-2EP C17511-2EP Liquid & Suction line 65084 65085 65085 Fan blade 57699 57699 57699 Fan motor C15239A C15239A C15239A Evaporator fan guard 65557 65557 65557 Temperature control 61283 61283 61283 Bulb clamp C6634 C6634 C6634 Wire harness, compressor bottom 65560 65560 65560 Wire harness, evaporator 65561 65561 65561 Lock 63762 63762 36762 Space, lock 63761-1 63761-1 63761-1 Lock rail 65432-24SS 65432-24SS 65432-24SS Grille rail 65432-12SS 65432-12SS 65432-12SS Condenser pan 65565-1 65565-1 65565-1 Condenser end panel 66215-1SS 66215-1SS 66215-1SS Grille, black 66210-12 66210-12 66210-12 Grille, SS 66210-12SS 66210-12SS 66210-12SS Condenser housing back 65435-12SS 65435-12SS 65435-12SS Evaporator, liquid & suction line cover 65576-1L 65576-4L 65576-2L Evaporator pan 65526-1 65526-2 65526-2 Door sill 65500-1 65500-1 65500-1 Door handle 65609-2 65609-2 65609-2 Door gasket 66237-4 66237-4 66237-4 Cabinet hinge group left 66264L 66264L 66264L Cabinet hinge group right 66264R 66264R 66264R Hinge pin 63679-1 63679-1 63679-1 *Replacement door RD-NL2 RD-NL2 RD-NL2 Waste tank 65559 65559 65559 Corner bumper C31726 C31726 C31726 Air distributor assembly C18942 C18943 C18944 Drainer insert 65510-1 65510-1 65510-1 Waste bin cover 66210-12C 66210-12C 66210-12C

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 11 of the Perlick DC84S user manual — For Single Valve Keg Coupler (Series D)
Page 11 · click to enlarge
Page 11

Replacement Parts – Concessionaire Dispensers

For Single Valve Keg Coupler (Series D)

Perlick DC84S — For Single Valve Keg Coupler (Series D) diagram (page 11)
Fig. 7 · For Single Valve Keg Coupler (Series D)

Item Part No. No. Description 1 32499 Probe assembly 2 F40184 Probe body 3 31080-2P Ball 4 43641-1 Ball retainer 5 31087-2P Probe washer 6 31089 “O” Ring - 3-per assembly 7 43061 Body 8 23682-2P Check valve 9 157R2P Washer 10 206B-1 Tailpiece 11 2026 Coupling nut 12 31088-2P Bottom seal washer 13 31084-1 Retaining screw 14 43002A Yoke assembly w/lock 15 43001A Yoke assembly standard 16 32474-1 Wrench

Perlick DC84S — For Single Valve Keg Coupler (Series D) diagram (page 11)
Fig. 8 · For Single Valve Keg Coupler (Series D)

Part No. Description 157L2P Beer line connector gasket 57F2P CO2 tank washer 1392R Red air hose 529 Beer hose 2928D Twin gauge CO2 regulator

DC Series 2, 3 and 4 Keg Concessionaire Portable Dispensers

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Page 12 of the Perlick DC84S user manual — Operations to Perform on Cabinet
Page 12 · click to enlarge
Page 12

Reversing Door Hinge

Tools Required

8. Re-assemble hinge brackets to unit. Bottom right bracket is assembled as the top left bracket. Top right bracket is assembled as the bottom left bracket.
  • #3 Phillips Screwdriver.
  • 1 / 16 ” Allen Wrench.
  • Flathead Screwdriver
9. Re-insert top hinge pin.
Perlick DC84S — Tools Required diagram (page 12)
Fig. 9 · Tools Required
10. Re-assemble lock rail from STEP #3

Top Hinge Bracket Bottom Hinge Bracket

Operations to Perform on Door

11. Remove bottom door hinge bracket from door assembly and remove door hinge bushing from bracket. Re-assemble door hinge bracket to previous position, without bushing.

Operations to Perform on Cabinet

1. Remove bottom hinge pin from assembly.
12. Remove top door hinge bracket from door assembly and assemble door hinge bushing from STEP 11 to bracket. Re-assemble door hinge bracket to previous position with bushing attached.
2. Carefully lift and tilt out door assembly from the unit and set aside.

Step #12 Step #11 Step #13

3. Remove lock rail from cabinet, requires removal of four screws.
13. Door with full length SS handle: There is no need to remove door handle. It will be positioned correctly when door is reversed.
4. Remove top hinge pin. Remove top and bottom hinge brackets from the unit.

Door with SS pull tab or handle with wrap- around bracket: Remove the two screws mounting the handle and reposition to appropriate location on the opposite side of the door.

5. Remove hinge bushing from bottom hinge bracket and assemble to top hinge bracket.

Top Hinge Bracket Bottom Hinge Bracket

14. Remove lock retainer and install on opposite end of door.
6. Taking care not to scratch the surface, remove hole plugs from the left hinge holes.
15. What was the door top is now the door bottom. Carefully lift the door onto the hinge brackets of the cabinet. The two hinge bushings should meet. Reinsert the bottom hinge pin to complete the door switching operation.
7. Insert hole plugs into vacant right hinge holes.
  • 8300 West Good Hope Road
  • Milwaukee, WI 53223
  • Phone 414-353-7060
  • Fax 414-353-7069 Toll Free 800-558-5592
  • E-Mail: Perlick@<a href="http://Perlick.com" rel="nofollow noopener" target="_blank">Perlick.com</a>
  • <a href="http://www.Perlick.com" rel="nofollow noopener" target="_blank">www.Perlick.com</a>

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.

Show 5 more labels / short text on this page
Step #14 · Remove these screws · Hinge Bushing · Step #7 · Step #6
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Perlick DC84S

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Perlick DC84S

Be the first to ask — other owners or our team will answer.

Original document

Perlick DC84S manual PDF

12 pages·1.4 MB·Webcam·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…