EN
Perle Systems logo
Official user manual

Perle Systems TS2

224 pages·4 MB·Network Card·PDF·ENDEFRITNLJA
Perle Systems TS2
Table of Contents 281 sections DS1/TS2 User’s Guide · Table of Contents · Preface · About This Book · … ShowHide
DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 1 of the Perle Systems TS2 user manual — January 2008
Page 1 · click to enlarge
Page 1

IOLAN

DS1/TS2 User’s Guide

Version 3.4

Part #5500162-34

January 2008

Page 2 of the Perle Systems TS2 user manual — DS1/TS2 User’s Guide
Page 2 · click to enlarge
Page 2

This document must not be reproduced in any way whatsoever, either printed or electronically, without the consent of:

Perle Systems Limited, 60 Renfrew Drive Markham, ON Canada L3R 0E1

Perle reserves the right to make changes without further notice, to any products to improve reliability, function, or design.

Perle, the Perle logo, and IOLAN are trademarks of Perle Systems Limited.

Microsoft, Windows 98, Windows NT, Windows 2000, Windows Server 2003, Windows XP, and Internet Explorer are trademarks of Microsoft Corporation.

Netscape is a trademark of Netscape Communications Corporation.

Mozilla Firefox is a trademark of the Mozilla Foundation.

Solaris is a registered trademark of Sun Microsystems, Inc. in the USA and other countries.

Perle Systems Limited, 2005-2008.

FCC Note The IOLAN Device Server has been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense.

EN 550221998, Class A, Note

Copyright Statement

Page 3 of the Perle Systems TS2 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 4 of the Perle Systems TS2 user manual — Table of contents
Page 4 · click to enlarge
Page 4

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 5 of the Perle Systems TS2 user manual — Table of contents
Page 5 · click to enlarge
Page 5

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 6 of the Perle Systems TS2 user manual — Table of contents
Page 6 · click to enlarge
Page 6

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 7 of the Perle Systems TS2 user manual — Table of contents
Page 7 · click to enlarge
Page 7

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 8 of the Perle Systems TS2 user manual — Table of contents
Page 8 · click to enlarge
Page 8

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 9 of the Perle Systems TS2 user manual — Table of contents
Page 9 · click to enlarge
Page 9

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 10 of the Perle Systems TS2 user manual — Table of contents
Page 10 · click to enlarge
Page 10

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 11 of the Perle Systems TS2 user manual — Table of contents
Page 11 · click to enlarge
Page 11

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 12 of the Perle Systems TS2 user manual — Table of contents
Page 12 · click to enlarge
Page 12

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 13 of the Perle Systems TS2 user manual — Table of contents
Page 13 · click to enlarge
Page 13

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 14 of the Perle Systems TS2 user manual — Table of contents
Page 14 · click to enlarge
Page 14

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 15 of the Perle Systems TS2 user manual — Table of contents
Page 15 · click to enlarge
Page 15

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 16 of the Perle Systems TS2 user manual — Table of contents
Page 16 · click to enlarge
Page 16

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Page 17 of the Perle Systems TS2 user manual — Documentation
Page 17 · click to enlarge
Page 17
Perle Systems TS2 — Preface diagram (page 17)
Fig. 1 · Preface

Preface

About This Book

This guide provides the information you need to:

z configure the IOLAN

z incorporate the IOLAN into your production environment

Intended Audience

This guide is for administrators who will be configuring the IOLAN.

Some prerequisite knowledge is needed to understand the concepts and examples in this guide:

z Knowledge of TFTP, the transfer protocol the IOLAN uses.

Documentation

The following documentation is included on the IOLAN installation CD:

z IOLAN 1-Port Quick Start Guide

z IOLAN 2-4-Port Quick Start Guide

z IOLAN I/O Quick Start Guide

z IOLAN DS1/TS2 User’s Guide

z IOLAN DS1/TS2 Command Line Reference Guide

z TruePort User’s Guide

z TruePort Installation and Configuration Guide for Windows NT

z Online Help in the DeviceManager (automatically installed with the DeviceManager application)

z Link to knowledge base

Page 18 of the Perle Systems TS2 user manual — Online Help
Page 18 · click to enlarge
Page 18

Typeface Conventions

Most text is presented in the typeface used in this paragraph. Other typefaces are used to help you identify certain types of information. The other typefaces are:

At the Cprompt, type: add host

This typeface is used for code examples and system-generated output. It can represent a line you type in, or a piece of your code, or an example of output.

Set the value to TRUE. The typeface used for TRUE is also used when referring to an actual value or identifier that you should use or that is used in a code example.

The italicized portion of these examples shows the typeface used for variables that are placeholders for values you specify. This is found in regular text and in code examples as shown. Instead of entering project, you enter your own value, such as stock_trader, and for yourcode, enter the name of your program.

run yourcode.exec

File, Save This typeface and comma indicates a path you should follow through the menus. In this example, you select Save from the File menu.

IOLAN User’s Guide This typeface indicates a book or document title.

See About the IOLAN on page 19 for more information.

This indicates a cross-reference to another chapter or section that you can click on to jump to that section.

Online Help

Online help is provided in the DeviceManager. You can click on the What’s This button ( or ) and then click on a field to get field-level help. Or, you can press the F1 key to get window-level help. You can also get the User’s Guide online by selecting Help, Help Topics.

Typeface Conventions · Typeface Example Usage · subscribe project subject

Page 19 of the Perle Systems TS2 user manual — IOLAN Family Models
Page 19 · click to enlarge
Page 19

Introduction Chapter 1 1

About the IOLAN

The IOLAN is an Ethernet communications/terminal server that allows serial devices to be connected directly to LANs. The IOLAN can connect to a wide range of devices including:

z Terminals for multi-user UNIX systems

z Data acquisition equipment (manufacturing, laboratory, scanners, etc.)

z Retail point-of-sale equipment (bar coding, registers, etc.)

z PCs using terminal emulation

z Modems for remote access and Internet access

z ISDN adapters for branch remote access and Internet access

z All types of serial printers

The performance and flexibility of the IOLAN allows you to use a wide range of high speed devices in complex application environments. The IOLAN products will work in any server environment running TCP/UDP/IP.

IOLAN Family Models

The IOLAN comes in several different models to meet your network needs:

z DS—Offered as a 1-port unit (DB25M, DB25F, RJ45, and DB9M interfaces available), this model provides general IOLAN functionality and supports software configurable serial interface protocols EIA-232/422/485.

z TS—This model is available with two serial ports (RJ45 only) and supports EIA-232 only. The TS model is similar to the DS model supporting only general IOLAN functionality.

z SDS—This model is available in both desktop and rack mount configurations. Both models support software configurable serial interface protocols EIA-232/422/485. The SDS model has the advanced secure IOLAN feature set in addition to the general IOLAN functionality.

z STS—This model comes in one desktop model and several rack mount configurations. All models support EIA-232 only. The STS model has the advanced secure IOLAN feature set in addition to the general IOLAN functionality.

z SCS—This model comes in several rack mount configurations. All models support EIA-232 only and have an internal PCI card interface. The SCS model has the advanced secure IOLAN feature set in addition to the general IOLAN functionality.

See Hardware on page 20 for information about the hardware specifications for your IOLAN model. See Software on page 21 for a list of the basic and advanced software features.

Page 20 of the Perle Systems TS2 user manual — SDS1 I/O
Page 20 · click to enlarge
Page 20

IOLAN Features

The IOLAN is a communications server used for making serial network connections. It attaches to your TCP/IP network and allows serial devices such as modems, terminals, or printers to access the LAN. It also allows LAN devices to access devices or equipment attached to IOLAN serial ports.

This section highlights the hardware and software components you can expect to find in your IOLAN model.

Hardware

Hardware Features IOLAN Models

SDS1 I/O

DS1 I/O

SDS2/4

STS4 D

SDS1

DS1

TS2

SDS

SCS

STS

RJ45 z

DB9M z

EIA-232 z

EIA-422 z

EIA-485 z

Serial Power In Pin

RJ45 z

Serial Power Out Pin

RJ45 z

Auto Sensing Ethernet Interface

10/100 z

10/100/1000 z z z

I/O Interface z z

Power over Ethernet z z

External AC z

Internal AC z z z

DC z z z

Dedicated Console Port z z z

Show 12 more labels / short text on this page
IOLAN Features · Desktop Rack Mount · DB25F z z · DB25M z z · Serial Connectors · Serial Interface · DB25F z z · DB25M z z · DB25F z z · DB25M z z · PCI Interface z · Power Supply
Page 21 of the Perle Systems TS2 user manual — Security
Page 21 · click to enlarge
Page 21

Software

This section describes the supported software features available.

Accessing the IOLAN All IOLAN models can be accessed through any of the following methods:

z Easy Config Wizard, an easy configuration wizard that allows you to quickly setup the IOLAN in a Windows environment

z DeviceManager, a fully functional Windows 98/NT/2000/ME/Server 2003/XP/Vista configuration/management tool

z WebManager, a web browser (HTTP) option for configuring/managing the IOLAN

z Menu, a window-oriented menu interface for configuration and user access

z CLI, a Command Line Interface option for configuration/management and user access

z SNMP, allowing remote configuration via SNMP as well as statistics gathering

z DHCP/BOOTP, a method of automatically updating the IOLAN

General Features Basic IOLAN software features are available on all IOLAN models.

z IPv6 support.

z Support for TCP/IP and UDP protocols including telnet and raw connections.

z Printer support via LPD and RCP.

z Virtual modem emulation.

z ‘Fixed tty’ support for several operating systems using Perle’s TruePort utility.

z DHCP/BOOTP for automated network-based setup.

z Dynamic statistics and line status information for fast problem diagnosis.

z Multisession support when accessing the IOLAN from either the serial port or the network.

z Modbus master/slave/gateway support.

z An SDK for custom programs and plugin support.

z I/O interface on the IOLAN I/O models (Analog, Temperature, Digital, and Relay).

z Ability to disable services (for example, Telnet, TruePort, Syslog, SNMP, Modbus, HTTP) for additional security.

Security

The IOLAN security features can include (depending on your IOLAN model):

z Supervisory and serial port password protection.

z Ability to set serial port access rights.

z Ability to assign users access level rights to control their access.

z Trusted host filtering (IP filtering), allowing only those hosts that have been configured in the IOLAN access to the IOLAN.

z Idle port timers, which close a connection that has not been active for a specified period of time.

z Ability to individually disable network services that won’t be used by the IOLAN.

IOLAN Features · Introduction 21

Page 22 of the Perle Systems TS2 user manual — Software
Page 22 · click to enlarge
Page 22

IOLAN Features

Page 23 of the Perle Systems TS2 user manual — Available Accessories
Page 23 · click to enlarge
Page 23

Hardware and Connectivity Chapter 2 2

Introduction

This chapter describes how to physically set up your IOLAN unit. It includes an overview of the IOLAN hardware components and how to power up the IOLAN to make sure it works correctly.

IOLAN Components

What’s Included

The following components are included with your product:

z External power supply

z Quick Start Guide (for I/O models, a soft copy exists on the CDROM)

z A CD-ROM containing documentation, firmware, configuration software, TruePort, etc.

z IOLAN models that have an RJ45 serial connector(s) come with an RJ45JDB9F adapter

What You Need to Supply

Before you can begin, you need to have the following:

z A serial cable(s) to connect serial devices to your IOLAN unit

z An Ethernet CAT5 10/100/1000BASE-T cable to connect the IOLAN unit to the network

Available Accessories

The following accessories are available for purchase for the various IOLAN models:

z DIN Rail Mounting Kit (35mm) for the desktop models

z 3 meter RJ45M-RJ45M 8-wire Sun/Cisco modular cable

z RJ45 to DB25 DTE Male adapter

z RJ45 to DB25 DCE Male adapter

z RJ45 to DB25 DTE Female adapter

z RJ45 to DB9 Male DTE adapter

z RJ45 to DB9 Female DTE adapter

Contact your distributor for details.

z IOLAN unit · z Warranty Card

Page 24 of the Perle Systems TS2 user manual — Overview
Page 24 · click to enlarge
Page 24

Power Supply Specifications

Desktop Models

Serial Only Models If you are providing a power supply for a desktop IOLAN model, your power supply must meet the following requirements:

z Output between 9-30V DC.

z DC barrel connector: The cable attached to the power supply should be about 20AWG, length 6 feet approx. The barrel dimensions of the cable-plug are OD=5.5, ID=2.1, and length= 9.5mm, with a straight barrel, and positive polarity on the inside and negative polarity on the outside.

z Power can also be provided by:

z Serial Port 1, pin 1 on the DS model

z Serial Port 2, pin 1 on the TS2 model

I/O Models The power supply for a desktop IOLAN I/O model must meet the following requirement:

z Output between 9-30V DC and a minimum of 600mA current.

Getting to Know Your IOLAN

This section describes the hardware components found on your IOLAN unit.

Overview

All IOLANs have the same basic hardware components to allow you to connect to serial devices, connect to the network, monitor LAN and serial activity, and manage the unit. Below is a list of these components:

z Serial Port(s)—Connector(s) that will be used to connect to a serial device.

z Activity—This LED flashes to indicate LAN activity.

z Link10/100—This LED indicates the Ethernet connection speed for desktop models:

– Green—10 Mbits

– Yellow—100 Mbits

– Off—no LAN connection

z Power/Ready—This LED can cycle through several colors (yellow, green, red) during a boot process, but should complete with a green light. If the LED is green after power up but continues to cycle on and off (flashes green), this indicates that the console switch is in the on position. You can learn more about the Power/Ready LED in Hardware Problems on page 217.

z External Power Supply—This is an external AC power supply.

z Console/Serial Switch—This switch determines whether serial port 1 functions as a serial port or a console port. If you have an I/O model, you will see two console switches. Console/Serial Switch 1 is used to determine the console/serial setting for Port 1 and the Console/Serial Switch 2 is not used.

z Reset—The inset RESET button will reboot the IOLAN if pushed in and released quickly. It will reset the IOLAN to factory defaults if pushed in and held for more than three seconds.

Power Supply Specifications

Page 25 of the Perle Systems TS2 user manual — TS2
Page 25 · click to enlarge
Page 25

Getting to Know Your IOLAN

z Tx—Flashes with transmit serial activity. There is a Tx LED for each serial port.

z Rx—Flashes with receive serial activity. There is an Rx LED for each serial port.

z Ethernet—The Ethernet connector.

DS1

This section describes the components found on the IOLAN DS1 model.

Perle Systems TS2 — DS1 diagram (page 25)
Fig. 2

The IOLAN DS1 has one serial connection that is one of the following connectors: DB25 male, DB25 female, RJ45, or DB9 male.

TS2

This section describes the components found on the IOLAN TS2 model.

Perle Systems TS2 — TS2 diagram (page 25)
Fig. 3

The 2-port IOLAN has two RJ45 serial connections.

Hardware and Connectivity 25

Show 16 more labels / short text on this page
z Serial Activity · Console/Serial · Switch Reset · External Power Supply · Ethernet · Power/Ready Link/10/100 · Activity (LAN) · Serial Activity · Console/Serial · Switch Reset · External Power Supply · Ethernet · Power/Ready Link/10/100 · Activity (LAN) · Serial Activity · Serial Ports
Page 26 of the Perle Systems TS2 user manual — I/O
Page 26 · click to enlarge
Page 26

Getting to Know Your IOLAN

I/O

This sections describes the basic components found on the IOLAN I/O models.

Top View The following image shows a typical IOLAN I/O model. Your I/O model may have I/O connectors in slightly different positions.

Perle Systems TS2 — I/O diagram (page 26)
Fig. 4

End View The IOLAN I/O model shown is an A4D2. Different IOLAN I/O models have different I/O connector configurations.

I/O connectors I/O connectors

Perle Systems TS2 — I/O diagram (page 26)
Fig. 5
Perle Systems TS2 — I/O diagram (page 26)
Fig. 6

All IOLAN I/O models have a DB9M serial connector.

Show 9 more labels / short text on this page
External Power Supply · Power/Ready · Link/10/100 · Activity (LAN) · Serial Activity · External Power Supply · Reset Console/Serial · Serial Port Ethernet · Switch
Page 27 of the Perle Systems TS2 user manual — Console/Serial Switch
Page 27 · click to enlarge
Page 27

Getting to Know Your IOLAN

Console/Serial Switch

Located at the back of the desktop IOLAN models is a switch that controls whether serial port 1 is in Console or Serial mode.

Perle Systems TS2 — Console/Serial Switch diagram (page 27)
Fig. 7 · Console/Serial Switch

Look at your model to verify the direction of the ON switch position. ON indicates that serial port 1 is in Console mode; otherwise serial port 1 is in Serial mode.

Console Mode Console mode is used when you have a direct connection between a serial device (like a terminal or a PC) and the IOLAN, accessed by the Admin user to configure/manage the IOLAN. Console mode automatically sets serial port settings as:

z Serial Interface to EIA-232

z Speed to 9600

z Flow Control to No

z Bits to 8

z Stop Bits to 1

z Parity to None

Console mode also displays extra system messages.

Serial port 1 will ignore any Serial Port settings when in Console mode, so you need to turn Console mode off to use serial port 1 in your network.

Serial Mode Serial mode is used when the IOLAN acts as a communications server, or anytime you are not connecting directly to the IOLAN to configure it. You can connect directly to the IOLAN in Serial mode, but the IOLAN will not display all the messages/information you will get in Console mode.

Hardware and Connectivity 27

Page 28 of the Perle Systems TS2 user manual — + - 9-30 VDC
Page 28 · click to enlarge
Page 28

Powering Up the IOLAN

Powering Up the IOLAN

Serial Only Models

To power up the IOLAN, perform the following steps:

1. Plug the external power supply into the IOLAN and then into the electrical outlet.
2. You will see the LEDs cycle for several seconds and then remain a solid green, indicating that it is ready to configure/use.

Before you start to configure the IOLAN, you should set the IOLAN jumpers if you want to terminate the line or use the power in pin feature (instead of an external power supply, if your desktop IOLAN model supports it).

In some circumstances, the setting of jumpers may be required:

z IOLAN DS models where EIA-422/485 line termination is required.

z IOLAN I/O models with Digital I/O for setting the channels as input or output.

z IOLAN I/O models with Analog I/O for setting Voltage/Current.

See Appendix C, Setting Jumpers on page 195 to see how to set the jumpers for your IOLAN desktop model.

I/O Models

To power up the IOLAN, perform the following steps:

1. Unplug the power plugable terminal block from the IOLAN.
2. Loosen the screws and then insert your positive (+) wire into the left terminal and screw it down. Insert the negative (-) wire into the right terminal and screw it down as shown below:

+ - 9-30 VDC

3. Plug the power terminal block back into the IOLAN.
4. Plug the power supply into the electrical outlet.
5. You will see the LEDs cycle for several seconds and then remain a solid green, indicating that it is ready to configure/use.

Before you start to configure the IOLAN, you should set the IOLAN jumpers for Digital I/O (see Digital I/O Module on page 198) or Analog Input (Analog Input Module on page 199) channels.

Left Right

Page 29 of the Perle Systems TS2 user manual — Configuration Methods Chapter 3 3
Page 29 · click to enlarge
Page 29

Configuration Methods Chapter 3 3

Introduction

This chapter provides information about the different methods you can use to configure the IOLAN. Before you can configure the IOLAN, you must assign an IP address to the IOLAN. See the Chapter 4, Getting Started on page 45 to find out how to assign an IP address to the IOLAN.

Once an IP address is assigned to the IOLAN, you can use any of the configuration methods to:

z Configure users.

z Configure IOLAN system parameters.

z Configure serial port parameters.

z Configure network parameters.

z Configure time parameters.

z Reboot the IOLAN.

z Manage I/O channels (when applicable).

z View statistics while connected to the IOLAN.

Page 30 of the Perle Systems TS2 user manual — Requires a Configured IP Address
Page 30 · click to enlarge
Page 30

Configuration Methods Overview

Some of the IOLAN configuration methods have the capability of configuring an IP address, which is the first required configuration step for a new IOLAN. Once the IOLAN has been assigned an IP address, any of the configuration methods can be used to configure the IOLAN.

Configures an IP Address

Following is a list of methods for setting the IOLAN IP address and a short explanation of when you would want to use that method:

z Easy Config Wizard—The Easy Config Wizard is available from the CD ROM included with your IOLAN. You can use the Easy Config Wizard to set the IOLAN’s IP address and configure serial ports. This configuration method would typically be used when:

z All ports are to have the same configuration.

z Only the most commonly used profiles are required.

z Straightforward application with no advanced functionality required.

z Easy Config is installed on a Windows-based PC with local network access to the IOLAN.

z DeviceManager—Use this method when you can connect the IOLAN to the network and access the IOLAN from a Windows® PC. The DeviceManager is a Windows-based application that can be used for IOLAN configuration and management. The DeviceManager can be used to assign an IP address and perform the complete configuration and management of the IOLAN.

z Direct Connection—Use this method when you can connect to the IOLAN from a serial terminal or from a computer running terminal emulation software over a serial port. Using this method, you will need to configure and/or manage the IOLAN using either the Menu or CLI.

z DHCP/BOOTP—Use this method when you have a BOOTP or DHCP server running and you can connect the IOLAN to your network. The IOLAN will automatically obtain an IP address from a local network DHCP/BOOTP server when this service is enabled (it is disabled by default). You can also configure certain IOLAN parameters that will be passed from the DHCP/BOOTP server to the IOLAN when it boots up. Other configurators such as DeviceManager, CLI, or Menu can be used to set this option, and obtain the initial IP address.

z ARP-Ping—Use this method when you can connect the IOLAN to the network and want to assign a temporary IP address to the IOLAN by specifying an ARP entry from your PC and then pinging it.

z IPv6 Network—When the IOLAN is connected to an IPv6 network, its local link address is determined using stateless auto configuration.

Once an IP address has been assigned to the IOLAN, in most cases, you can continue to use the same method if it is a configurator or you can switch to any other configuration method.

Requires a Configured IP Address

The following configuration methods require that an IP address already be assigned to the IOLAN.

z WebManager—WebManager is a fully functional, browser-based configuration method.

Configuration Methods Overview

Page 31 of the Perle Systems TS2 user manual — Easy Config Wizard
Page 31 · click to enlarge
Page 31

Easy Config Wizard

The Easy Config Wizard is a configuration wizard that will configure all the serial ports on your IOLAN to one of the following:

z TruePort (Virtual COM Port)

z TCP Sockets (Raw TCP)

z Printer (not supported on DS1/TS2 models)

You can launch the Easy Config Wizard from the Perle website or from the installation CD-ROM.

Perle Systems TS2 — Easy Config Wizard diagram (page 31)
Fig. 8 · Easy Config Wizard

The Easy Config Wizard has been designed to walk you through the configuration process for any of the available configuration options shown on the Welcome window.

Show 5 more labels / short text on this page
Easy Config Wizard · z Console Management · z Terminal · z Serial Tunneling · Configuration Methods 31
Page 32 of the Perle Systems TS2 user manual — Connecting to the IOLAN Using DeviceManager
Page 32 · click to enlarge
Page 32

DeviceManager

Overview

The DeviceManager is a Windows-based application that can be used to connect to the IOLAN to actively manage and configure it or can create new IOLAN configurations offline. See Chapter 5, Using DeviceManager and WebManager on page 53 for information on configuring/managing the IOLAN with DeviceManager.

Access Platforms

The DeviceManager can be run from Windows 98/NT/2000/ME/Server 2003/XP/Vista. DeviceManager can be installed from the product CD-ROM or downloaded from the Perle website. Unless the IOLAN has already been configured with a Gateway, DeviceManager can only access IOLANs in the local subnet. The DeviceManager can be accessed by only the admin user.

Unique Features

DeviceManager supports the following unique features:

z The ability to download the same configuration file to several IOLANs in one operation.

z The ability to save a configuration file locally in text format, in addition to the binary format.

z The ability to create a configuration file without being connected to the IOLAN.

z The ability to open a session to the IOLAN and download a (saved) configuration file to it.

z The ability to download custom files, such as new terminal definitions and a custom language files to the IOLAN.

Connecting to the IOLAN Using DeviceManager

Before you can use DeviceManager, you need to install it on your Windows operating system from the IOLAN CD-ROM or you can download it from the Perle website. After the DeviceManager application is installed, click Start, All Programs, Perle, DeviceManager, DeviceManager to start the application. When you launch the DeviceManager, it will scan the network for IOLANs:

Perle Systems TS2 — Connecting to the IOLAN Using DeviceManager diagram (page 32)
Fig. 9 · Connecting to the IOLAN Using DeviceManager

DeviceManager

Page 33 of the Perle Systems TS2 user manual — DeviceManager
Page 33 · click to enlarge
Page 33

All discovered IOLAN will be displayed on the list along with their name and IP address. When a new IOLAN is discovered on the network, that has not yet been assigned an IP address, it will be displayed with an IP Address of Not Configured. To configure the IP address, click on the IOLAN and then click the Assign IP button.

Perle Systems TS2 — DeviceManager diagram (page 33)
Fig. 10 · DeviceManager

Choose the method you want to use to assign an IP address to the IOLAN:

z Type in the IP address that you want to assign to this IOLAN

z Enable the Have the IOLAN automatically get a temporary IP Address option. This will turn on DHCP/BOOTP, so the IOLAN will attempt to get its IP address from your DHCP/BOOTP server. If you don’t have a DHCP/BOOTP server, DeviceManager will temporarily assign an IP address in the range of 169.254.0.1-169.254.255.255 that will be used only for the duration of the DeviceManager/IOLAN communication.

After you configure the IP address, click the Assign IP button.

The refreshed list will now display the assigned IP address for the new IOLAN. To connect to the IOLAN, click the IOLAN entry and click OK. You will be asked to supply the Admin password (the factory default password is superuser).

Perle Systems TS2 — DeviceManager diagram (page 33)
Fig. 11 · DeviceManager

If you have a successful connection, the DeviceManager will retrieve the configuration and then display it the IOLAN’s System Information and you can begin configuring the IOLAN.

DeviceManager · Configuration Methods 33

Page 34 of the Perle Systems TS2 user manual — Using DeviceManager
Page 34 · click to enlarge
Page 34

Using DeviceManager

After you have successfully connected to the IOLAN, you will see the following window:

Perle Systems TS2 — Using DeviceManager diagram (page 34)
Fig. 12 · Using DeviceManager

You navigate through the different configuration windows by selecting an option in the left-hand navigation tree. If double-click on option that is next to a folder, more navigation are displayed when you click on it:

Perle Systems TS2 — Using DeviceManager diagram (page 34)
Fig. 13 · Using DeviceManager

The Network folder contains two configuration options, IP Address and Advanced. Notice that when the IP Address option is selected, there are more navigation options in the form of the tabs, IP Settings and Advanced.

When you have completed all your configuration changes, click the Download Changes button to download the configuration to the IOLAN. You must reboot the IOLAN to make those configuration changes take effect.

Show 7 more labels / short text on this page
DeviceManager · Menu Options/Icons · Navigation · Tree · Configuration/Info · Download Button · Navigation Tabs
Page 35 of the Perle Systems TS2 user manual — Connecting to the IOLAN Using WebManager
Page 35 · click to enlarge
Page 35

WebManager

Overview

The WebManager is a web-browser based method of configuring/managing the IOLAN. It follows the same design as the DeviceManager, so it is easy to switch between the WebManager and DeviceManager when configuring your IOLAN. See Chapter 5, Using DeviceManager and WebManager on page 53 for information on configuring/managing the IOLAN with DeviceManager.

Access Platforms

You can access the IOLAN through WebManager from any system that can run a web browser. WebManager can be accessed by the admin user or any user who has Admin Level privileges.

Unique Features

WebManager supports the following unique features:

z The ability to open a session to the IOLAN and download a (saved) configuration file to it.

z The ability to download/upload keys/certificates to/from the IOLAN.

z The ability to download custom files, such as new terminal definitions and a custom language files to the IOLAN.

Connecting to the IOLAN Using WebManager

Before you can connect to the IOLAN using WebManager, the IOLAN must already be configured with a known IP address; see Setting Up the Network on page 46 to configure an IP address on your IOLAN.

To connect to the IOLAN through the WebManager:

1. Open your web browser and type in the IP address of the IOLAN that you want to manage/configure and press Enter ; for example: http://123.123.123.123.
2. If you successfully connect to the IOLAN, a login screen will appear.
Perle Systems TS2 — Connecting to the IOLAN Using WebManager diagram (page 35)
Fig. 14 · Connecting to the IOLAN Using WebManager
3. If you are accessing the IOLAN in non-secure HTTP, just type in the Admin password (the factory default password is superuser )

WebManager · Configuration Methods 35

Page 36 of the Perle Systems TS2 user manual — Using WebManager
Page 36 · click to enlarge
Page 36

Using WebManager

After you have successfully logged into WebManager, you will see the following:

Perle Systems TS2 — Using WebManager diagram (page 36)
Fig. 15 · Using WebManager

You navigate through the different configuration windows by selecting an option in the left-hand navigation tree. If click on option that is next to a folder, more navigation are displayed when you click on it:

Perle Systems TS2 — Using WebManager diagram (page 36)
Fig. 16 · Using WebManager

The Network folder contains two configuration options, IP Address and Advanced. Notice that when the IP Address option is selected, there are more navigation options in the form of the tabs, IP Settings and Advanced.

Remember that in the WebManager, it is necessary to press the Apply button to save your changes.

Show 5 more labels / short text on this page
WebManager · Navigation · Tree · System Information · Navigation Tabs
Page 37 of the Perle Systems TS2 user manual — DS1#
Page 37 · click to enlarge
Page 37

Command Line Interface

Overview

The Command Line Interface (CLI) is a command line option for IOLAN configuration/management. See the Command Line Interface Reference Guide for a full breakdown of all the CLI commands and their functionality.

Access Platforms

The CLI is accessed by any application that supports a Telnet session to the IOLAN’s IP address, such as Putty, SecureCRT, or from a command prompt. You can also access the CLI from a dumb terminal or PC connected to a serial port.

Unique Features

The CLI supports the following unique features:

z You can access the IOLAN from any application that supports Telnet.

z Ability to clear the ARP table (cache).

Connecting to the IOLAN Using the CLI

There are two ways you can access the IOLAN, through the network (Ethernet connection) or through the serial connection. If you are accessing the IOLAN through the network, the IOLAN must already have a known IP address configured; see Using a Direct Serial Connection to Specify an IP Address on page 47 getting started for information on configuring an IP address.

Through the Network To connect to the IOLAN through the network to configure/manage it using the CLI, do the following:

1. Start a Telnet session to the IOLAN’s IP address; for example:

telnet 10.10.201.100

2. You will get a Login: prompt. You can login as the admin user or as a user with Admin Level rights. If the login is successful, you will get a prompt that displays the IOLAN model and number of ports:
Loginadmin Password:

DS1#

You will see a prompt that displays the model and number of the IOLAN. You are now ready to start configuring/managing your IOLAN using the CLI.

Command Line Interface · Configuration Methods 37

Page 38 of the Perle Systems TS2 user manual — Connecting to the IOLAN Using the Menu
Page 38 · click to enlarge
Page 38

Through the Serial Port To connect to the IOLAN through the serial port to configure/manage it using the CLI (or Menu), see Using a Direct Serial Connection to Specify an IP Address on page 47.

After you have established a connection to the IOLAN, you will get a Login: prompt. You can login as the admin user or as a user with Admin Level rights. If the login is successful, you will get a prompt that displays the IOLAN model and number of ports:

Loginadmin Password:

DS1#

You will see a prompt that displays the model and number of the IOLAN. You are now ready to start configuring/managing your IOLAN using the CLI

Using the CLI

After you have successfully logged in, you can start configuring/managing the IOLAN by typing in commands at the prompt. If you are not sure what commands are available, you can type a ? (question mark) at any time during a command to see your options.

See the Command Line Interface Reference Guide for more information about the CLI.

Menu

Overview

The Menu is a graphical representation of the CLI. You can look up Menu parameter explanations in the Command Line Interface Reference Guide. The only operations that the Menu does not support are the downloading and uploading of files to/from the IOLAN.

Access Platforms

The Menu is accessed by any application that supports a Telnet session to the IOLAN’s IP address, such as Putty, SecureCRT, or from a command prompt. You can also access the Menu from a dumb terminal or PC connected to a serial port.

Unique Features

The Menu supports the following unique feature:

z You can access the IOLAN from any application that supports Telnet.

z You can access the IOLAN using a terminal emulator and a serial connection.

Connecting to the IOLAN Using the Menu

To connect the IOLAN using the Menu, follow the directions for Connecting to the IOLAN Using the CLI on page 37.

Menu

Page 39 of the Perle Systems TS2 user manual — Using the Menu
Page 39 · click to enlarge
Page 39

Using the Menu

After you have successfully logged in, type screen at the prompt and press Enter. You will be asked to enter a terminal type, and then you will see the following Menu:

Perle Systems TS2 — Using the Menu diagram (page 39)
Fig. 17 · Using the Menu

To navigate through the Menu options, do the following:

1. Highlight a Menu option by using the keyboard up and down arrows to navigate the list.
2. When the Menu item you want to access is highlighted, press the Enter key to either get to the next list of options or to get the configuration screen, depending on what you select.
3. When you are done configuring parameters in a screen, press the Enter key and then the Enter key again to Accept and exit the form .
4. If you want to discard your changes, press the Esc key to exit a screen, at which point you will be prompted with Changes will be lost, proceed? (y/n) , type y to discard your changes or n to return to the screen so you can press Enter to submit your changes.
5. If there are a number of predefined options available for a field, you can scroll through those items by pressing the Space Bar or you can type l (lowercase L) to get a list of options, use the up/down arrows to highlight the option you want, and then press Enter to select it.

Menu · Configuration Methods 39

Page 40 of the Perle Systems TS2 user manual — Using DHCP/BOOTP
Page 40 · click to enlarge
Page 40

DHCP/BOOTP

DHCP/BOOTP

Overview

Several IOLAN parameters can be configured through a DHCP/BOOTP server during the IOLAN bootup. This is particularly useful for configuring multiple IOLANs.

Not all configuration parameters are supported in the DHCP/BOOTP configuration (see DHCP/BOOTP Parameters on page 41 for supported configuration parameters), so you will need to use another configuration method, such as DeviceManager, WebManager or CLI, to complete the configuration.

Unique Features

DHCP/BOOTP supports the following unique features:

z DHCP/BOOTP can supply the IOLAN’s IP address.

z The DHCP/BOOTP server can configure certain server and user configuration parameters when the IOLAN is booted.

z The DHCP/BOOTP server can auto-configure the IOLAN with basic setup information (IP address, subnet/prefix bits, etc.).

z The DHCP/BOOTP server can download a new version of firmware when the IOLAN is rebooted.

z The DHCP/BOOTP server can download a full configuration file when the IOLAN is rebooted.

Connecting to the IOLAN Using DHCP/BOOTP

The IOLAN will automatically request an IP address from the DCHP/BOOTP server when the Obtain IP address automatically using DHCP/BOOTP parameter is enabled. To enable the Obtain IP address automatically using DHCP/BOOTP parameter, follow the directions in Using a Direct Serial Connection to Enable BOOTP/DHCP on page 48.

Using DHCP/BOOTP

To use DHCP/BOOTP, edit the bootp file with IOLAN configuration parameters. You can use DHCP/BOOTP to perform the following actions on a single or multiple IOLANs on bootup:

z auto-configure with minimal information; for example, only an IP address

z auto-configure with basic setup information (IP address, subnet/prefix bits, etc.)

z download a new version of firmware

z download a full configuration file

DHCP/BOOTP is particularly useful for multiple installations: you can do all the IOLANs’ configuration in one DHCP/BOOTP file, rather than configure each IOLAN manually. Another advantage of DHCP/BOOTP is that you can connect the IOLAN to the network, turn on its power and let autoconfiguration take place. All the configuration is carried out for you during the DHCP/BOOTP process.

Page 41 of the Perle Systems TS2 user manual — DHCP/BOOTP
Page 41 · click to enlarge
Page 41

DHCP/BOOTP

DHCP/BOOTP Parameters

The following parameters can be set in the DHCP/BOOTP bootp file:

z SW_FILE—The full path, pre-fixed by hostname/IP address (IPv4 or IPv6), and file name of the firmware update.

z CONFIG_FILE—The full path, pre-fixed by hostname/IP address (IPv4 or IPv6), and file name of the configuration file. Note: these parameters include clear text user passwords.

z GUI_ACCESS—Access to the IOLAN from the HTTP WebManager. Values are on or off.

z SECURITY—Restricts IOLAN access to devices listed in the IOLAN’s host table. Values are yes or no.

z TFTP_RETRY—The number of TFTP attempts before aborting. This is a numeric value, for example, 5.

z TFTP_TMOUT—The time, in seconds, before retrying a TFTP download/upload. This is a numeric value, for example, 3.

z CUSTOM_LANG—The full path, pre-fixed by a hostname/IP address (IPv4 or IPv6), and file name of a translated language file. For example, 192.101.34.211 /accounting/Iolan_ds_german.txt.

z EXTRA_TERM1—(EXTRA_TERM2, EXTRA_TERM3) The full path, pre-fixed by a hostname/IP address (IPv4 or IPv6), and file name of a termcap file for a specific terminal type.

Configuration Methods 41

Page 42 of the Perle Systems TS2 user manual — Connecting to the IOLAN Using SNMP
Page 42 · click to enlarge
Page 42

SNMP

SNMP

Overview

The IOLAN supports configuration and management through SNMP. SNMP Management tools (SNMP client/MIB browser software) can be used to set IOLAN configuration parameters and/or view IOLAN statistics.

Before you can configure/manage the IOLAN using SNMP, although you need to set the IOLAN IP address and configure a read-write user for SNMP version 3 or a community for SNMP version 1 or 2. You can use DeviceManager, CLI, or the Menu to set the IP address and user/community (don’t forget to reboot the IOLAN before connecting with the SNMP manager to make your changes take effect).

Access Platforms

You can access the IOLAN SNMP MIB from any system that runs your SNMP client/MIB browser software.

Unique Features

SNMP supports the following unique features:

z You can configure SNMP traps.

z Since not all versions of SNMP support secure communication, password parameters must be set using another configuration method.

Connecting to the IOLAN Using SNMP

Before you can connect to the IOLAN through an SNMP Management tool or MIB browser, you need to set the following components through another configuration method.

1. Configure a known IP address on the IOLAN.
2. Configure a read-write user for SNMP version 3 or a community for SNMP version 1 or 2 on the IOLAN.
3. Reboot the IOLAN to make sure the changes take effect.

To connect to the IOLAN through an SNMP Management tool or MIB browser, do the following:

1. Load the perle-ds.MIB file from the IOLAN CD-ROM or Perle website into your SNMP manager (this MIB works for all DS1 and TS2 models).
2. Verify that the read-write user for SNMP version 3 or a community for SNMP version 1 or 2 match the configuration on the IOLAN.
3. Type in the IOLAN’s IP address and connect to the IOLAN.

You are now ready to start configuring the IOLAN using SNMP.

z SNMPv2-SMI · z SNMPv2-TC · z IPV6-TC

Page 43 of the Perle Systems TS2 user manual — SNMP
Page 43 · click to enlarge
Page 43

SNMP

Using the SNMP MIB

After you have successfully connected to the IOLAN through your SNMP Management tool or MIB browser, expand the PERLE-IOLAN-DS-MIB folder to see the IOLAN’s parameter folders. Below is an example of the configurable parameters under the ServicesInfo folder.

Perle Systems TS2 — SNMP diagram (page 43)
Fig. 18

The first variable in each folder is the Status variable, for example, serviceStatus. When you perform a GET on this variable, one of the following values will be returned:

z 1—Indicates that the container folder is active with no changes.

z 2—Indicates that the container folder is active with change(s).

Once you have completed setting the variables in a folder, you will want to submit your changes to the IOLAN. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6.

z 4—Indicates that the changes in the container folder are to be submitted to the IOLAN.

z 6—Indicates that the changes in the container folder are to be discarded.

If you want to save all the changes that have been submitted to the IOLAN, you need to expand the adminInfo container folder and SET the adminFunction to 1 to write to FLASH. To make the configuration changes take effect, SET the adminFunction to 3 to reboot the IOLAN.

Configuration Methods 43

Page 44 of the Perle Systems TS2 user manual — SNMP
Page 44 · click to enlarge
Page 44

SNMP

Page 45 of the Perle Systems TS2 user manual — Easy Configuration Wizard
Page 45 · click to enlarge
Page 45

Getting Started Chapter 4 4

Introduction

There are several different configuration methods available to configure the IOLAN (see Chapter 3, Configuration Methods on page 29 for more information). This chapter describes the three main minimal configuration requirements for the IOLAN through either Easy Config Wizard (cannot configure users using this method), DeviceManager, or WebManager:

1. Setting up the network —This minimally consists of configuring an IP address or enabling DHCP/BOOTP. Once the IOLAN has an IP address, you can use any configuration method.
2. Setting up the serial ports —You will want to select the serial port profile that matches the serial port requirement/scenario for your serial device.
3. Setting up users —This is an optional step, which is only required when your implementation requires users to access the IOLAN.

Easy Configuration Wizard

The Easy Config Wizard quickly sets up the IOLAN’s network configuration and all serial ports to one of the following:

z Console Management—Allows users on the network to connect to a serial device that is connected to a serial port on the IOLAN.

Page 46 of the Perle Systems TS2 user manual — Using DeviceManager
Page 46 · click to enlarge
Page 46

Setting Up the Network

z TruePort (Virtual COM Port)—Allows a networked system to communicate with your serial device through a virtual COM or TTY port, using the Perle TruePort software.

z TCP Sockets (Raw TCP)—Allows hosts on the network to communicate with a serial device that requires raw data throughput (such as a printer or card reader) connected to the IOLAN serial port.

z Terminal—Allows a terminal device to connect to a specified host on the network through a serial port on the IOLAN.

z Printer—(SDS/STS/SCS only) Allows hosts on the network to talk to a printer using LPD connected to the IOLAN.

z Serial Tunneling—Allows IOLANs on the network to establish a virtual link between their serial ports. Typically, one IOLAN’s serial port is configured as a Tunnel Server and the other IOLAN’s serial port is configured as a Tunnel Client.

Setting Up the Network

The most important part of setting up the network is assigning an IP address to the IOLAN, whether this is a static IP address or enabling a DHCP/BOOTP-assigned IP address. You should also assign a name the IOLAN, to make it easier to recognize. This section deals primarily with setting the IP address.

Using DeviceManager

To use the DeviceManager, you must first install it on a Windows operating system. The DeviceManager is able to automatically discover all IOLANs on your local network, even if they have not yet been assigned an IP address. If routers on the network have been setup to propagate multicasts, DeviceManager will also be able to discover IOLANs in other networks. The DeviceManager installation wizard can be found on the CD-ROM included in the IOLAN package.

1. Connect the IOLAN to the network.
2. Power on the IOLAN.
3. From the CD-ROM that was included in the IOLAN packaging, select the DeviceManager link.
4. Click on the link under Location and click Open to automatically start the DeviceManager installation.
5. Install the DeviceManager by following the installation wizard. On the last window, check the Yes, I want to launch DeviceManager now. box and click the Finish button.
6. When you launch the DeviceManager, it will automatically scan the local network and display any IOLANs that it can find.
7. Any IOLAN that does not have an IP address will be displayed as Not Configured , with the Model and MAC Address to identify the IOLAN. Highlight the IOLAN that you want to assign an IP address to and click the Assign IP button.
8. Choose the method you want to use to assign an IP address to the IOLAN:

z Type in the IP address that you want to assign to this IOLAN.

z Enable the Have the IOLAN automatically get a temporary IP address option. This will turn on DHCP/BOOTP, so the IOLAN will attempt to get its IP address from your DHCP/BOOTP server. If you don’t have a DHCP/BOOTP server, DeviceManager will temporarily assign an IP address in the range of 169.254.0.1-169.254.255.255 that will be used only for the duration of the DeviceManager/IOLAN communication.

Click the Assign IP button.

9. You are now ready to configure the IOLAN. Double-click the IOLAN you just configured IP address for to open a configuration session. Type superuser (the factory default Admin user password) in the Login window and click OK .
Page 47 of the Perle Systems TS2 user manual — Using WebManager
Page 47 · click to enlarge
Page 47

Setting Up the Network

10. Expand the Server Configuration folder and select Server . Verify the IP address configuration. You should also enter a name in the Server Name field to make the IOLAN easily identifiable.
11. To make your edits take effect, you need to download the new configuration file and then reboot the IOLAN. Download the configuration file to the IOLAN by selecting Tools , Download Configuration to Unit or click the Download All Changes button.
12. Reboot the IOLAN by selecting Tools , Reboot Server or click the Reboot IOLAN button.

For more information on configuring the IOLAN using DeviceManager, see Chapter 5, Using DeviceManager and WebManager on page 53.

Using WebManager

To use the WebManager as your configurator, you must first assign an IP address to the IOLAN. You can use the Easy Config Wizard to assign an IP address to the IOLAN or any of the other methods described in this section. Once the IP address is assigned to the IOLAN, simply type the IP address into the Address field of your web browser and press the Enter key.

Using a Direct Serial Connection to Specify an IP Address You can connect to the IOLAN’s serial console port using a PC with a terminal emulation package, such as HyperTerminal or a terminal.

1. Connect the IOLAN to your PC or dumb terminal. Make sure the DIP switch is in Console mode (desktop models, this sets the IOLAN serial port 1 to EIA-232). When connecting a terminal or PC directly (without modems), the EIA-232 signals need to be crossed over (‘null modem’ cable). See Appendix B, EIA-232 Cabling Diagrams on page 191 for cabling diagrams.
2. Using a PC emulation application, such as HyperTerminal, or from a dumb terminal, set the Port settings to 9600 Baud, 8 Data bits, No Parity, 1 Stop Bits, and No Hardware Flow control to connect to the IOLAN.
3. When prompted, type admin for the User and superuser for the Password. You should now see the a prompt that displays the model type and port number; for example, DS1# .
4. You are now logged into the IOLAN and can set the IP address by typing from the command line using the Command Line Interface (CLI).

Type:

set server internet

Where ipv4address is the IP Address being assigned to the IOLAN.

5. Type the following command:
6. If you are going to use another configuration method, such as WebManager or DeviceManager, unplug a desktop IOLAN. On a desktop IOLAN, change the DIP switch to Off Serial (DIP switch in the up position) and connect it to your serial device. Plug the IOLAN back in, automatically rebooting the IOLAN in the process.
7. If you want to complete the configuration using a direct connection, see Command Line Interface on page 37 and/or Menu on page 38 . After you complete configuring the IOLAN, unplug the IOLAN. If this is a desktop model, change the IOLAN DIP switch to Off Serial (DIP switch in the up position) and connect it to your serial device. Plug the IOLAN back in, automatically rebooting the IOLAN in the process.

Using a Direct Serial Connection to Enable BOOTP/DHCP If you are using BOOTP, you need to add an entry in the BOOTP server for the IOLAN that associates the MAC address (found on the back of the IOLAN) and the IP address that you want to

save · Getting Started 47

Page 48 of the Perle Systems TS2 user manual — Using WebManager
Page 48 · click to enlarge
Page 48

Setting Up the Network

assign to the IOLAN. After you have made the MAC address/IP address association for BOOTP, use the following directions for BOOTP or DHCP.

You can connect to the IOLAN using a PC with a terminal emulation package, such as HyperTerminal or a dumb terminal.

1. Connect the IOLAN to your PC or dumb terminal. Make sure the DIP switch is in Console mode (desktop models, this sets the IOLAN serial port to EIA-232). When connecting a terminal or PC directly (without modems), the EIA-232 signals need to be crossed over (‘null modem’ cable). See Appendix B, EIA-232 Cabling Diagrams on page 191 for cabling diagrams.
2. Using a PC emulation application, such as HyperTerminal, or from a dumb terminal, set the Port settings to 9600 Baud, 8 Data bits, No Parity, 1 Stop Bits, and No Hardware Flow control to connect to the IOLAN.
3. When prompted, type admin for the User and superuser for the Password. You should now see the a prompt that displays the model type and port number; for example, DS1# .
4. You are now logged into the IOLAN and can set the IP address by typing from the command line using the Command Line Interface (CLI). Type the following command:

set server internet dhcp/bootp on

5. Type the following command:
6. The the following command:
7. When the IOLAN reboots, it will automatically poll for an IP address from the DHCP/BOOTP server.
8. To view the DHCP/BOOTP assigned IP address, type the following command:

If for some reason it cannot obtain an IP address from your DHCP/BOOTP server, you will have to either reconnect to the IOLAN on the console port and reboot it or push the Reset to Factory button to access the IOLAN.

You are now ready to configure the IOLAN. See Chapter 3, Configuration Methods on page 29 for information on the different IOLAN configuration methods.

save · reboot · show interface ethernet

Page 49 of the Perle Systems TS2 user manual — For an IPv6 Network
Page 49 · click to enlarge
Page 49

Setting Up the Network

Using ARP-Ping

You can use the ARP-Ping (Address Resolution Protocol) method to temporarily assign an IP address and connect to your IOLAN to assign a permanent IP address. To use ARP-Ping to temporarily assign an IP address:

1. From a local UNIX/Linux host, type the following at the system command shell prompt:

arp -s a.b.c.d aa:bb:cc:dd:ee:ff

On a Windows® 98 or newer system, type the following at the command prompt:

arp -s a.b.c.d aa-bb-cc-dd-ee-ff

(where a.b.c.d is the IPv4 address you want to temporarily assign to the IOLAN, and aa:bb:cc:dd:ee:ff is the Ethernet (MAC) address of IOLAN (found on the back of the unit).

2. Whether you use UNIX or Windows ® , you are now ready to ping to the IOLAN. Here is a UNIX example of the sequence to use:

arp -s 192.168.209.8 00:80:d4:00:33:4e ping 192.168.209.8

From the ping command issued in step 2, the IOLAN will pickup and use the IP address entered into the ARP table in step 1. You are now ready to configure the IOLAN. See Chapter 3, Configuration Methods on page 29 for information on the different IOLAN configuration methods.

For an IPv6 Network

The IOLAN has a factory default link local IPv6 address that takes the following format:

IOLAN MAC Address00-80-D4-AB-CD-EF
Link Local Addressfe80::0280:D4ff:feAB:CDEF

The IOLAN will also listen for IPv6 router advertisements to learn a global address. You do not need to configure an IPv4 address for IOLANs residing in an IPv6 network.

You are now ready to configure the IOLAN. See Chapter 3, Configuration Methods on page 29 for information on the different IOLAN configuration methods.

Getting Started 49

Page 50 of the Perle Systems TS2 user manual — Setting Up the Serial Port(s)
Page 50 · click to enlarge
Page 50

Setting Up the Serial Port(s)

Setting Up the Serial Port(s)

The DeviceManager and WebManager have the following serial port profiles that will simplify serial port setup:

Perle Systems TS2 — Setting Up the Serial Port(s) diagram (page 50)
Fig. 19 · Setting Up the Serial Port(s)

z Console Management—The Console Management profile configures a serial port to provide network access to a console or administrative port. This profile sets up a serial port to support a TCP socket that listens for a Telnet connection from the network.

z TruePort—The TruePort profile configures a serial port to connect network servers or workstations running the TruePort software to a serial device as a virtual COM port. This profile is ideal for connecting multiple serial ports to a network system or server.

z TCP Sockets—The TCP Sockets profile configures a serial port to allow a serial device to communicate over a TCP network. The TCP connection can be configured to be initiated from the network, a serial device connected to the serial port, or both. This is sometimes referred to as a raw connection or a TCP raw connection.

z UDP Sockets—The UDP Sockets profile configures a serial port to allow communication between the network and serial devices connected to the IOLAN using the UDP protocol.

z Terminal—The Terminal profile configures a serial port to allow network access from a terminal connected to the IOLAN’s serial port. This profile is used to access predefined hosts on the network from the terminal.

z Serial Tunneling—The Serial Tunneling profile configures a serial port to establish a virtual link over the network to a serial port on another IOLAN. Both IOLAN serial ports must be configured for Serial Tunneling (typically one serial port is configured as a Tunnel Server and the other serial port as a Tunnel Client).

z Virtual Modem—The Virtual Modem (Vmodem) profile configures a serial port to simulate a modem. When the serial device connected to the IOLAN initiates a modem connection, the IOLAN starts up a TCP connection to another IOLAN configured with a Virtual Modem serial port or to a host running a TCP application.

Page 51 of the Perle Systems TS2 user manual — Setting Up the Serial Port(s)
Page 51 · click to enlarge
Page 51

Setting Up the Serial Port(s)

z Control Signal I/O—The Control Signal I/O profile enables the use of the EIA-232 serial port signal pins to be used as assigned Digital Inputs or Digital Outputs.

z Modbus Gateway—The Modbus Gateway profile configures a serial port to act as a Modbus Master Gateway or a Modbus Slave Gateway.

z Custom Application/Plugin—The Custom Application/Plugin profile configures a serial port to run a custom application or IOLAN plugin. After you download the custom application files and specify the application name and any parameters you want to pass to it, the IOLAN will execute the application when the serial port is started.

Each serial port profile contains all the parameters that are required to completely configure the serial port scenario represented by the profile.

To select a serial port profile in the DeviceManager, connect through the DeviceManager to the IOLAN you are configuring and select Serial, Serial Ports in the navigation pane. Highlight the serial port you want to configure and then click Edit.

Perle Systems TS2 — Setting Up the Serial Port(s) diagram (page 51)
Fig. 20 · Setting Up the Serial Port(s)

When the default serial port profile Terminal displays, click the Change Profile button and select the appropriate profile for the serial port. See Chapter 7, Configuring Serial Ports on page 67 for more information on the serial port profiles and their configuration parameters.

Getting Started 51

Page 52 of the Perle Systems TS2 user manual — Setting Up Users
Page 52 · click to enlarge
Page 52

Setting Up Users

When you have a user who is accessing a device connected to a serial port from the network or who is accessing the network from a device connected to a serial port through the IOLAN, you can create a user account and configure the user’s access privileges. Notice that there is a Default user; the Default user’s parameters are inherited by users accessing a serial port configured for the Terminal profile with the Conenct to remote system option enabled.

To add a user account, click on the Users page in the navigation pane.

Perle Systems TS2 — Setting Up Users diagram (page 52)
Fig. 21 · Setting Up Users

Click the Add button to create a user account.

Perle Systems TS2 — Setting Up Users diagram (page 52)
Fig. 22 · Setting Up Users

To quickly add a user, fill out the field in the General tab and click OK.

See Chapter 8, Configuring Users on page 117 for more information about the other user parameters you can configure.

Setting Up Users

Page 53 of the Perle Systems TS2 user manual — Using DeviceManager and WebManager Chapter 5 5
Page 53 · click to enlarge
Page 53

Using DeviceManager and WebManager Chapter 5 5

Introduction

The DeviceManager and WebManager IOLAN managers have been designed to be very similar to use. DeviceManager is a Windows-based application and WebManager is a browser-based application. Both options use the IOLAN’s IP address to access the IOLAN; the DeviceManager can be used to assign an IP address to a new IOLAN and the WebManager requires that the IOLAN already have an IP address before it can be used to configure the IOLAN.

When using WebManager, you are required to click the Apply button each time you make a change to a configuration window/tab. In DeviceManager, you must download your configuration changes to the IOLAN either periodically or after you are done with the configuration changes. From both managers you must reboot the IOLAN in order for you configuration changes to take effect.

Page 54 of the Perle Systems TS2 user manual — DeviceManager
Page 54 · click to enlarge
Page 54

Navigating DeviceManager/WebManager

The DeviceManager and WebManager have very similar navigation methods. The left-hand side of the manager is the navigation tree and the center is the configuration area. The DeviceManager has menu and quick access buttons, whereas the WebManager has system information and some navigation options on the far right-hand side.

DeviceManager

The DeviceManager uses a folder/page navigation tree. You can expand the folders to see the available configuration pages. When you access a configuration page, you can often navigate the tabs in the configuration area to access all of the configuration options.

Show 4 more labels / short text on this page
Navigating DeviceManager/WebManager · Menu/Quick Access Buttons · Navigation Tree · Configuration Area
Page 55 of the Perle Systems TS2 user manual — WebManager
Page 55 · click to enlarge
Page 55

WebManager

The WebManager uses a expandable/collapsible buttons with folders and pages for the navigation tree. You can expand the buttons to view the folders and pages to see the available configuration options. When you access a configuration page, you can often navigate the tabs in the configuration area to access all of the configuration options.

Using DeviceManager and WebManager 55

Show 5 more labels / short text on this page
Navigating DeviceManager/WebManager · Navigation · Tree · System Info/ Navigation · Configuration Area
Page 56 of the Perle Systems TS2 user manual — Starting a New Session
Page 56 · click to enlarge
Page 56

Using DeviceManager to Connect to the IOLAN

Using DeviceManager to Connect to the IOLAN

DeviceManager can connect to existing IOLANs or assign an IP address to a new IOLAN. Whenever you connect to the IOLAN through the DeviceManager, you connect as the Admin user and must supply the password for the Admin user.

Starting a New Session

To start a new session and connect to the IOLAN using the DeviceManager:

1. Start the DeviceManager by selecting Start , All Programs , Perle , DeviceManager , DeviceManager .
2. When the DeviceManager starts, it searches the network for IOLANs.
Perle Systems TS2 — Starting a New Session diagram (page 56)
Fig. 23 · Starting a New Session

If your IOLAN is not in the local network and you do not have a multicast enabled router in your network and therefore is not displayed in the selectable list, but can be pinged from your PC, you can add it to the selectable list by clicking the Add button.

Perle Systems TS2 — Starting a New Session diagram (page 56)
Fig. 24 · Starting a New Session

Type in the IOLAN’s IP address and click Add Server. Select the manually added server to connect to it.

Page 57 of the Perle Systems TS2 user manual — Assigning a Temporary IP Address to a New IOLAN
Page 57 · click to enlarge
Page 57

Using DeviceManager to Connect to the IOLAN

Assigning a Temporary IP Address to a New IOLAN

You can temporarily assign an IP address to the IOLAN that is connected to your local network segment, for the purpose of connecting to it and downloading a configuration file (containing a permanent IP address). To temporarily assign an IP address to the IOLAN, do the following:

1. Click the Refresh button. The IOLAN will be displayed in the IP Address column as Not Configured .
2. Select the new IOLAN and click the Assign IP button. The following window is displayed:
Perle Systems TS2 — Assigning a Temporary IP Address to a New IOLAN diagram (page 57)
Fig. 25 · Assigning a Temporary IP Address to a New IOLAN
Perle Systems TS2 — Assigning a Temporary IP Address to a New IOLAN diagram (page 57)
Fig. 26 · Assigning a Temporary IP Address to a New IOLAN

Version 3.2 or higher Version 3.1 or lower

3. Type a valid temporary IP address into the address field or, in version 3.2 or higher, enable the Have the IOLAN automatically get a temporary IP address. If you enable the temporary IP address, the IOLAN will enable DHCP/BOOTP on your IOLAN and attempt to get an IP address from the DHCP/BOOTP server (this will permanently enable DHCP/BOOTP in your IOLAN’s configuration, until you change it). If your network does not have a DHCP/BOOTP server, the IOLAN will temporarily assign an IP address in the range of 169.254.0.1-169.254.255.255 (this IP address is only assigned for the duration of the DeviceManager/IOLAN connection).

4. Click the Assign IP button.
5. Double-click the IOLAN in the IOLAN List . If this is the first time you are accessing the IOLAN, type in the factory default Admin password, superuser , and click OK . The DeviceManager will display a window indicating that it is trying to authenticate and connect you on the IOLAN.
6. If the authentication and connection are successful, the Server Info window is displayed. You are now ready to configure the IOLAN. If authentication was unsuccessful, try to connect to the IOLAN again; you probably mistyped the password for the Admin user.

For more information about managing the IOLAN, see Configuration Files on page 59.

Using DeviceManager and WebManager 57

Page 58 of the Perle Systems TS2 user manual — Logging in to the IOLAN
Page 58 · click to enlarge
Page 58

Using DeviceManager to Connect to the IOLAN

Adding/Deleting Manual IOLANs

To permanently add/delete IOLANs to/from the IOLAN List, click the Add button. The following window is displayed:

To permanently add IOLANs to the IOLAN list, type in the IP address of the IOLAN and click the Add Server button. To permanently delete IOLANs from the IOLAN list, select the IOLAN’s IP address and click the Delete Server button.

Logging in to the IOLAN

To log in to the IOLAN, double-click on the IOLAN in the Device Server List. You will be prompted for the Admin Password (the default is superuser).

Perle Systems TS2 — Logging in to the IOLAN diagram (page 58)
Fig. 27 · Logging in to the IOLAN

If the authentication and connection are successful, the IOLAN’s Server Info window is displayed.

If you cannot connect to the IOLAN, you can highlight the IOLAN and click the Ping button to verify that the DeviceManager can communicate with the IOLAN’s IP Address. If the ping times out, then you might need to set up a Gateway in your IOLAN or verify that your network is communicating correctly.

Page 59 of the Perle Systems TS2 user manual — Creating a New IOLAN Configuration in DeviceManager
Page 59 · click to enlarge
Page 59

Using WebManager to Connect to the IOLAN

Using WebManager to Connect to the IOLAN

WebManager can only connect to IOLANs that already have an assigned IP address. To connect to the IOLAN, type the IP address of the IOLAN into the Address field as such: http://10.10.234.34.

You will see the login screen.

Logging into the IOLAN

Type in the Admin password in the Password field and click the Login button.

Configuration Files

Creating a New IOLAN Configuration in DeviceManager

In DeviceManager, when you select File, New, the New Configuration window is displayed.

Perle Systems TS2 — Creating a New IOLAN Configuration in DeviceManager diagram (page 59)
Fig. 28 · Creating a New IOLAN Configuration in DeviceManager

Select the IOLAN model for which you want to create a new configuration file. Any configuration file created in this manner can only be save locally. To download a created configuration file, you must first connect to the IOLAN, import the created configuration file into DeviceManager (this is not available in WebManager), and then download the configuration file to the IOLAN and reboot it.

Using DeviceManager and WebManager 59

Page 60 of the Perle Systems TS2 user manual — Managing the IOLAN
Page 60 · click to enlarge
Page 60

Opening an Existing Configuration File

If you select the File, Open, a browse window is opened so you can select the configuration file you want to edit. IOLAN configuration files saved in the DeviceManager can be in the IOLAN-native binary format (.dme) or as a text file (.txt), which can be edited with a text editor. Either configuration version can be imported into the DeviceManager. IOLAN configuration files saved from WebManager can also be opened into DeviceManager.

Importing an Existing Configuration File

If you have a local, saved configuration file that you want to download to the IOLAN, you must first connect to the IOLAN that you want to download the configuration file to. Once you have successfully logged into the IOLAN, in DeviceManager select Tools, Import Configuration from a File and in WebManager select Administration, Restore/Backup. You need to download the file in DeviceManager and in both managers you need to reboot the IOLAN.

Managing the IOLAN

Most of the management tasks, such as setting the time/date, downloading keys/certificates, downloading firmware, downloading custom files, resetting serial ports, etc., are found under the Tools menu option in the DeviceManager and under Administration in WebManager.

Managing the IOLAN

Page 61 of the Perle Systems TS2 user manual — Network Settings Chapter 6 6
Page 61 · click to enlarge
Page 61

Network Settings Chapter 6 6

Introduction

The Network section is used to configure the parameters that identify the IOLAN within the network and how the IOLAN accesses hosts on the network. The following configuration windows are available:

Perle Systems TS2 — Network Settings Chapter 6 6 diagram (page 61)
Fig. 29 · Network Settings Chapter 6 6

z IP Settings—This window sets up IOLAN’s name, IP address, and Ethernet information. See IP Settings on page 62 for more information.

z Advanced—This window configures hosts that the IOLAN will be communicating with and routes. See Advanced on page 64 for more information on these options.

Page 62 of the Perle Systems TS2 user manual — Field Descriptions
Page 62 · click to enlarge
Page 62

IP Settings

IP Settings

Overview The parameters in IP settings are used to access the IOLAN and are how the IOLAN accesses the network.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 62)
Fig. 30 · Field Descriptions

Configure the following parameters:

System Name The System Name is used for informational purposes by such tools as the DeviceManager and is also used in conjunction with the Domain field to construct a fully qualified domain name (FQDN). Default: localhost

Domain This field is combined with the System Name to construct the fully qualified domain name (FQDN). For example, if the domain is mycompany.com and the Server Name is set to accounting, the FQDN would be accounting.mycompany.com.

Obtain IP Address automatically using DHCP/BOOTP

When enabled, the IOLAN will request an IP address from the DHCP/BOOTP server. By default, when this option is enabled, the IOLAN will also attempt to retrieve the DNS server, WINS server, and default gateway from the DHCP/BOOTP server. Default: Disabled

Use the following IP Address

Assign a specific IP address to the IOLAN. Field Options: IPv4 address

IP Address The IOLAN’s unique IPv4 network IP address. If you are using the IOLAN in an IPv6 network, this field can be left blank.

Subnet Mask The network subnet mask. For example, 255.255.0.0.

IP Settings

Page 63 of the Perle Systems TS2 user manual — Field Descriptions
Page 63 · click to enlarge
Page 63

Default Gateway Specify the gateway IP address that will provide general access beyond the local network. Field Options: IPv4 address

Default Gateway Obtain Automatically

When DHCP/BOOTP is enabled, you can enable this option to have the IOLAN receive the Default Gateway IP address from the DHCP/BOOTP server. Default: Enabled

Advanced

Overview The Advanced tab configures the Ethernet interface hardware speed and duplex.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 63)
Fig. 31 · Field Descriptions

Configure the following parameter:

Ethernet1 Speed and Duplex

Define the Ethernet connection speed. Data Options:

z Auto—automatically detects the Ethernet interface speed and duplex

z 10 Mbps Half Duplex

z 10 Mbps Full Duplex

z 100 Mbps Half Duplex

z 100 Mbps Full Duplex Default: Auto

IP Settings

Page 64 of the Perle Systems TS2 user manual — Field Descriptions
Page 64 · click to enlarge
Page 64

Advanced

Host Table

Overview The Host table contains the list of hosts that will be accessed by an IP address from the IOLAN. This table will contain a symbolic name for the host as well as its IP address. When a host entry is required elsewhere in the configuration, the symbolic name will be used.

Functionality You can configure up to 20 hosts using IPv4 or IPv6 internet addresses on desktop IOLAN models.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 64)
Fig. 32 · Field Descriptions

Configure the appropriate parameters:

IP Filtering Data Options:

z Allow all traffic—Allows any host to connect to the IOLAN.

z Allow traffic only to/from hosts defined with IP addresses—A security feature that when enabled, the IOLAN will only accept data from or send data to hosts configured in the IOLAN’s Host Table. Default: Allow all traffic

Add Button Adds a host to the host table.

Edit Button Changes a host that already exists in the host table.

Delete Button Deletes a host from the host table.

Advanced

Page 65 of the Perle Systems TS2 user manual — Field Descriptions
Page 65 · click to enlarge
Page 65

Adding/Editing a Host

Perle Systems TS2 — Adding/Editing a Host diagram (page 65)
Fig. 33 · Adding/Editing a Host

Configure the appropriate parameters:

Host Name The name of the host. This is used only for the IOLAN configuration. Text Characteristics: Up to 14 characters, no spaces.

IP Address The host’s IP address. Text Characteristics: IPv4 or IPv6 Address

Route List

Overview Entering routes in the routing list enables the identification of gateways to be used for accessing specific hosts or external networks from the IOLAN's local network.

Functionality There are three types of routes:

z Default—A route that provides general access beyond your local network.

z Host—A route defined for accessing a specific host external to your local network.

z Network—A route defined for accessing a specific network external to your local network.

You can specify up to 20 routes on desktop IOLAN models.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 65)
Fig. 34 · Field Descriptions

The following buttons are available:

Add Button Adds a route to the Route List.

Advanced

Page 66 of the Perle Systems TS2 user manual — Adding/Editing Routes
Page 66 · click to enlarge
Page 66

Edit Button Changes an existing route in the Route List.

Delete Button Deletes a route from the Route List.

Adding/Editing Routes

From the Route List tab, if you click the Add or Edit button, you will be able to add a new or edit an existing route.

Perle Systems TS2 — Adding/Editing Routes diagram (page 66)
Fig. 35 · Adding/Editing Routes

Configure the appropriate parameters:

Type Specify the type of route you want to configure. Data Options:

z Host—A route defined for accessing a specific host external to your local network.

z Network—A route defined for accessing a specific network external to your local network.

z Default—A route which provides general access beyond your local network. Default: Default

IP Address When the route Type is defined as Host, this field will contain the IP address of the host. If the route Type is defined as Network, the network portion of the IP address must be specified and the Host port of the address will be set to 0. Example: to access network 10.10.20, the address 10.10.20.0 would be specified in this field. Format: IPv4 or IPv6 Address

IPv4 Subnet Mask When the route is a Network route, you must specify the network’s subnet

mask.

IPv6 Subnet Bits If the IP address is IPv6, then you must specify the network’s subnet bits. Range: 0-128

Host The host that is being used at the route gateway.

Advanced

Page 67 of the Perle Systems TS2 user manual — Functionality
Page 67 · click to enlarge
Page 67

Configuring Serial Ports Chapter 7 7

Introduction

The Serial section is used to configure the serial ports on your IOLAN. The following configuration windows are available:

Perle Systems TS2 — Configuring Serial Ports Chapter 7 7 diagram (page 67)
Fig. 36 · Configuring Serial Ports Chapter 7 7

z Serial Ports—This window sets up the type of connection that the serial port is being used for. This is accomplished by selecting a connection profile and then configuring the applicable parameters for that profile. See Serial Ports on page 67 for more information.

z Advanced—This window configures those parameters that are applicable to specific environments. You will find modem and TruePort configuration options, in addition to others, here. See Advanced on page 113 for more information.

Serial Ports

Overview

Each IOLAN serial port can be connected to serial device. Each serial port can then be configured according to a serial port profile that coincides with the serial device attached to that serial port and how the serial device is accessed/used.

Functionality

When you select the Serial Ports navigation option, you will see a list with the number of serial ports on your IOLAN. As you configure the serial ports, the information for each serial port is displayed.

Perle Systems TS2 — Functionality diagram (page 67)
Fig. 37 · Functionality

To configure/change a serial port, click the Edit button.

Page 68 of the Perle Systems TS2 user manual — Configuring Serial Ports
Page 68 · click to enlarge
Page 68

Editing a Serial Port In the Serial Port Settings window, click on a serial port and then click the Edit button, the following window is displayed:

Perle Systems TS2 — Configuring Serial Ports diagram (page 68)
Fig. 38 · Configuring Serial Ports

Serial Ports

Page 69 of the Perle Systems TS2 user manual — Configuring Serial Ports
Page 69 · click to enlarge
Page 69

Click the Change Profile button to select a different serial port profile if you don’t want the displayed profile:

As you select the different serial port profiles, a short description and a picture representing a typical application of the profile is displayed. When you have selected the appropriate profile for the serial port, click OK and those serial port profile configuration options will be displayed.

Resetting a Serial Port When you change a serial port’s configuration, you can download the configuration file to the IOLAN and then reset a specific serial port(s) to see how you change affects the serial port’s behavior. To reset a serial port, select Tools, Reset, Serial Port(s).

Perle Systems TS2 — Configuring Serial Ports diagram (page 69)
Fig. 39 · Configuring Serial Ports

Serial Ports

Page 70 of the Perle Systems TS2 user manual — Common Tabs
Page 70 · click to enlarge
Page 70

Serial Port Profiles

Common Tabs

Overview There are several functions that are common to more than one profile. These functions are:

z Hardware—Configure the physical serial line parameters. See Hardware Tab Field Descriptions on page 70.

z Packet Forwarding—Configure data packet parameters. See Packet Forwarding Tab Field Descriptions on page 72.

Hardware Tab Field Descriptions The Hardware tab configures all the serial port hardware connection information.

Perle Systems TS2 — Common Tabs diagram (page 70)
Fig. 40 · Common Tabs

Configure the following parameters:

Serial Interface Specifies the type of serial line that is being used with the IOLAN. Data Options: EIA-232, EIA-422, or EIA-485. TS2 models support only EIA-232. Default: EIA-232

Speed Specifies the baud rate of the serial line; keep in mind that speed is affected by the length of the cable. You can also specify a custom baud rate. When you enter a custom baud rate, the IOLAN will calculate the closest baud rate available to the hardware. The exact baud rate calculated can be viewed in the Serial Ports statistics. Range: 50-230400, custom supports 50-1843200 Default: 9600

Data Bits Specifies the number of bits in a transmitted character. Default: 8

Serial Port Profiles

Page 71 of the Perle Systems TS2 user manual — Serial Port Profiles
Page 71 · click to enlarge
Page 71

Parity Specifies the type of parity being used for the data communication on the serial port. If you want to force a parity type, you can specify Mark for 1or Space for 0. Data Options: Even, Odd, Mark, Space, None Default: None

Stop Bits Specifies the number of stop bits that follow a byte. Data Options: 1,1.5, 2 Default: 1

Duplex Used with a EIA-485 serial interface, specify whether the serial port is Full Duplex (communication both ways at the same time) or Half Duplex (communication in one direction at a time). Default: Full

TX Driver Control Used with a EIA-485 serial interface, if your application supports RTS

(Request To Send), select this option. Otherwise, select Auto. Default: Auto

Flow Control Defines whether the data flow is handled by the software (Soft), hardware (Hard), Both, or None. Data Options: Soft, Hard, Both, None Default: None

Enable Inbound Flow Control

Determines if input flow control is to be used. Default: Enabled

Enable Outbound Flow Control

Determines if output flow control is to be used. Default: Enabled

Monitor DSR Specifies whether the EIA-232 signal DSR (Data Set Ready) should be monitored. This is used with modems or any device that sends a DSR signal. When it is monitored and the IOLAN detects a DSR signal, the line profile is started. If both Monitor DCD and Monitor DSR are enabled, both signals must be detected before the line profile is started. Default: Disabled

Monitor DCD Specifies whether the EIA-232 signal DCD (Data Carrier Detect) should be monitored. This is used with modems or any other device that sends a DCD signal. When it is monitored and the IOLAN detects a DCD signal, the line profile is started. If both Monitor DCD and Monitor DSR are enabled, both signals must be detected before the line profile is started. Default: Disabled

This parameter applies only to EIA-485 Half Duplex mode. All characters will be echoed to the user and transmitted across the serial ports. Some EIA-485 applications require local echo to be enabled in order to monitor the loopback data to determine that line contention has occurred. If your application cannot handle loopback data, echo suppression should be enabled. Default: Disabled

Serial Port Profiles · Enable Echo Suppression

Page 72 of the Perle Systems TS2 user manual — Serial Port Profiles
Page 72 · click to enlarge
Page 72

Packet Forwarding Tab Field Descriptions The Packet Forwarding tab can be used to control/define how and when data packets are sent from the IOLAN.

Perle Systems TS2 — Serial Port Profiles diagram (page 72)
Fig. 41 · Serial Port Profiles

Configure the following parameters:

Minimize Latency This option ensures that all application data is immediately forwarded to the serial device and that every character received from the device is immediately sent on the network. Select this option for timing-sensitive applications. Default: Enabled

This option provides optimal network usage while ensuring that the application performance is not compromised. Select this option when you want to minimize overall packet count, such as when the connection is over a WAN. Default: Disabled

This option detects the message, packet, or data blocking characteristics of the serial data and preserves it throughout the communication. Select this option for message-based applications or serial devices that are sensitive to inter-character delays within these messages. Default: Disabled

The minimum time, in milliseconds, between messages that must pass before the data is forwarded by the IOLAN. Range: 0-65535 Default: 250 ms

This option allows you to define the packet forwarding rules based on the packet definition or the frame definition. Default: Disabled

Show 5 more labels / short text on this page
Serial Port Profiles · Optimize Network Throughput · Prevent Message Fragmentation · Delay Between Messages · Custom Packet Forwarding
Page 73 of the Perle Systems TS2 user manual — Serial Port Profiles
Page 73 · click to enlarge
Page 73

Packet Definition When enabled, this group of parameters allows you to set a variety of packet definition options. The first criteria that is met causes the packet to be transmitted. For example, if you set a Force Transmit Timer of 1000 ms and a Packet Size of 100 bytes, whichever criteria is met first is what will cause the packet to be transmitted. Default: Enabled

Packet Size The number of bytes that must be received from the serial port before the packet is transmitted to the network. A value of zero (0) ignores this parameter. Range: 0-1024 bytes Default: 0

Idle Time The amount of time, in milliseconds, that must elapse between characters before the packet is transmitted to the network. A value of zero (0) ignores this parameter. Range: 0-65535 ms Default: 0

When enabled, specifies the character that when received will define when the packet is ready for transmission. The actual transmission of the packet is based on the Trigger Forwarding Rule. Range: Hex 0-FF Default: 0

When enabled, creates a sequence of characters that must be received to specify when the packet is ready for transmission (if the End Trigger1 character is not immediately followed by the End Trigger2 character, the IOLAN waits for another End Trigger1 character to start the End Trigger1/End Trigger2 character sequence). The actual transmission of the packet is based on the Trigger Forwarding Rule. Range: Hex 0-FF Default: 0

Frame Definition When enabled, this group of parameters allows you to control the frame that is transmitted by defining the start and end of frame character(s). If the internal buffer (1024 bytes) is full before the EOF character(s) are received, the packet will be transmitted and the EOF character(s) search will continue. Default: Disabled

SOF1 Character When enabled, the Start of Frame character defines the first character of the frame, any character(s) received before the Start of Frame character is ignored. Range: Hex 0-FF Default: 0

SOF2 Character When enabled, creates a sequence of characters that must be received to create the start of the frame (if the SOF1 character is not immediately followed by the SOF2 character, the IOLAN waits for another SOF1 character to start the SOF1/SOF2 character sequence). Range: Hex 0-FF Default: 0

When enabled, the SOF1 or SOF1/SOF2 characters will be transmitted with the frame. If not enabled, the SOF1 or SOF1/SOF2 characters will be stripped from the transmission. Default: Disabled

Show 4 more labels / short text on this page
Serial Port Profiles · Enable Trigger1 Character · Enable Trigger2 Character · Transmit SOF Character(s)
Page 74 of the Perle Systems TS2 user manual — Console Management Profile
Page 74 · click to enlarge
Page 74

EOF1 Character Specifies the End of Frame character, which defines when the frame is ready to be transmitted. The actual transmission of the frame is based on the Trigger Forwarding Rule. Range: Hex 0-FF Default: 0

EOF2 Character When enabled, creates a sequence of characters that must be received to define the end of the frame (if the EOF1 character is not immediately followed by the EOF2 character, the IOLAN waits for another EOF1 character to start the EOF1/EOF2 character sequence), which defines when the frame is ready to be transmitted. The actual transmission of the frame is based on the Trigger Forwarding Rule. Range: Hex 0-FF Default: 0

Determines what is included in the Frame (based on the EOF1 or EOF1/EOF2) or Packet (based on Trigger1 or Trigger1/Trigger2). Choose one of the following options:

z Strip-Trigger—Strips out the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2, depending on your settings.

z Trigger—Includes the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2, depending on your settings.

z Trigger+1—Includes the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2, depending on your settings, plus the first byte that follows the trigger.

z Trigger+2—Includes the EOF1, EOF1/EOF2, Trigger1, or Trigger1/Trigger2, depending on your settings, plus the next two bytes received after the trigger. Default: Trigger

Console Management Profile

Overview The Console Management profile provides access through the network to a console or administrative port of a server or router attached to the IOLAN’s serial port. This profile configures the IOLAN’s serial port to set up a TCP socket that will listen for a Telnet connection from the network.

Functionality Use the Console Management profile when you are configuring users who need to access a serial console port from the network.

Perle Systems TS2 — Console Management Profile diagram (page 74)
Fig. 42 · Console Management Profile

Serial Port Profiles · Trigger Forwarding Rule

Page 75 of the Perle Systems TS2 user manual — Console Management Profile
Page 75 · click to enlarge
Page 75

General Tab Field Descriptions The Console Management General tab configures how the serial port will be accessed by the user through the network.

Perle Systems TS2 — Console Management Profile diagram (page 75)
Fig. 43 · Console Management Profile

Configure the following parameters:

Protocol Specify the connection method that users will use to communicate with a serial device connected to the IOLAN through the network. Default: Telnet

Listen for Connections on TCP Port

The port number that the IOLAN will listen on for incoming TCP connections. Default: 10001, depending on the serial port number

Enable IP Aliasing Enables/disables the ability to access a serial device connected to the serial port

by an IP address (or host name that can be resolved to the Internet Address in a DNS network) instead of the IOLAN’s IP address and port number. Default: Disabled

IP Address Users can access serial devices connected to the IOLAN through the network by the specified Internet Address (or host name that can be resolved to the Internet Address in a DNS network). Data Options: IPv4 Address

Serial Port Profiles

Page 76 of the Perle Systems TS2 user manual — Console Management Profile
Page 76 · click to enlarge
Page 76

Advanced Tab Field Descriptions The Console Management Advanced tab configures serial port options that may be required by certain applications.

Perle Systems TS2 — Console Management Profile diagram (page 76)
Fig. 44 · Console Management Profile

Configure the following parameters:

Authenticate User Enables/disables login/password authentication for users connecting from the network. Default: Disabled

Enable TCP Keep Alive

Enables a per-connection TCP keepalive feature. After the configured number of seconds, the connection will send a gratuitous ACK to the network peer, thus either ensuring the connection stays active OR causing a dropped connection condition to be recognized. This parameter needs to be used in conjunction with Monitor Connection Status Interval parameter found in the Serial, Advanced, Advanced Settings tab. The interval determines how long the IOLAN will wait during inactivity before "testing" the connection. It should be noted that if a network connection is accidentally dropped, it can take as long as the specified interval before anyone can reconnect to the serial port. Default: Disabled

Enable Message of the Day (MOTD)

Enables/disables the display of the message of the day. Default: Disabled

Multisessions The number of extra network connections available on a serial port (available only on 2 port+ models), in addition to the single session that is always available. Enabling multisessions will permit multiple users to monitor the same console port. Each user monitoring the port can be assigned different privileges to this port. Data Range: 0-7 multisessions per serial port Default: 0

Idle Timeout Use this timer to close a connection because of inactivity. When the Idle Timeout expires, the IOLAN will end the connection. Default: 0 seconds so the port will never timeout Range: 0-4294967 seconds (about 49 days)

Serial Port Profiles

Page 77 of the Perle Systems TS2 user manual — Console Management Profile
Page 77 · click to enlarge
Page 77

Break Handling Specifies how a break is interpreted. Data Range:

z None—The IOLAN ignores the break key completely and it is not passed through to the host.

z Local—The IOLAN deals with the break locally. If the user is in a session, the break key has the same effect as a hot key.

z Remote—When the break key is pressed, the IOLAN translates this into a telnet break signal which it sends to the host machine.

z Break Interrupt—On some systems such as SunOS, XENIX, and AIX, a break received from the peripheral is not passed to the client properly. If the client wishes to make the break act like an interrupt key (for example, when the stty options -ignbrk and brkintr are set). Default: None

Dial In If the console port is remote and will be dialing in via modem or ISDN TA, enable this parameter. Default: Disabled

Dial Out If you want the modem to dial a number when the serial port is started, enable this parameter. Default: Disabled

Dial Timeout The number of seconds the IOLAN will wait to establish a connection to a remote modem. Range: 1-99 Default: 45 seconds

Dial Retry The number of times the IOLAN will attempt to re-establish a connection with a remote modem. Range: 0-99 Default: 2

Modem The name of the predefined modem that is used on this line.

Phone The phone number to use when Dial Out is enabled.

Serial Port Profiles

Page 78 of the Perle Systems TS2 user manual — TruePort Profile
Page 78 · click to enlarge
Page 78

TruePort Profile

Overview TruePort is COM Port redirector that is supplied with the IOLAN. TruePort can be installed as a client on a Workstation or Server and supports a variety of operating systems. It, in conjunction with the IOLAN, emulates a local serial port (COM port), to the application, to provide connectivity to a remote serial device over the network. The TruePort profile operates in conjunction with the TruePort software.

Functionality TruePort is a COM port redirector utility for the IOLAN. It can be run in two modes (these modes will be set on the client software when it is configured):

z TruePort Full mode—This mode allows complete device control and operates as if the device was directly connected to the Workstation/Server’s local serial port. It provides a complete COM port interface between the attached serial device and the network. All serial controls, baud rate control, etc., are sent to the IOLAN and replicated on its associated serial port.

z TruePort Lite mode—This mode provides a simple raw data interface between the application and the remote serial port. Although the port will still operate as a COM port, control signals are ignored. In this mode, the serial communications parameters must be configured on the IOLAN.

See the TruePort User’s Guide for more details about the TruePort client software.

Perle Systems TS2 — TruePort Profile diagram (page 78)
Fig. 45 · TruePort Profile

Serial Port Profiles

Page 79 of the Perle Systems TS2 user manual — TruePort Profile
Page 79 · click to enlarge
Page 79

General Tab Field Descriptions The TruePort General tab determines how the TruePort connection is initiated and then sets up the appropriate connection parameters.

Perle Systems TS2 — TruePort Profile diagram (page 79)
Fig. 46 · TruePort Profile

Configure the following parameters:

Connect to remote system

When enabled, the IOLAN initiates communication to the TruePort client. Default: Enabled

Host Name The configured host that the IOLAN will connect to (must be running TruePort). Default: None

TCP Port The TCP Port that the IOLAN will use to communicate through to the TruePort client. Default: 10001 for serial port 1, then increments by one for each serial port

Connect to Multiple Hosts

When enabled, the IOLAN will establish a connection to multiple clients (Hosts). When using the multiple hosts feature, all TruePort clients must be running in Lite mode. Default: Disabled

Define Additional Hosts Button

Click this button to define the hosts that this serial port will connect to. This button is also used to define the Primary/Backup host functionality.

See Adding/Editing Additional TruePort Hosts on page 80 for more information.

When enabled, the IOLAN will wait for connections to be initiated by the TruePort Client. Default: Disabled

TCP Port The TCP Port that the IOLAN will use to communicate through to the TruePort client. Default: 10001 for serial port 1, then increments by one for each serial port

Allow Multiple Hosts to Connect

When this option is enabled, multiple hosts can connect to a serial device that is connected to this serial port. Note: These multiple clients (Hosts) need to be running TruePort in Lite mode. Default: Disabled

Serial Port Profiles · Listen for Connection

Page 80 of the Perle Systems TS2 user manual — TruePort Profile
Page 80 · click to enlarge
Page 80

Adding/Editing Additional TruePort Hosts You can define a list of hosts that the serial device will communicate to through TruePort Lite or a primary/backup host.

Perle Systems TS2 — TruePort Profile diagram (page 80)
Fig. 47 · TruePort Profile

Configure the following parameters:

Define additional hosts to connect to

When this option is enabled, you can define up to 49 hosts that the serial device connected to this serial port will attempt communicate to. With this mode of operation, the IOLAN will connect to multiple hosts simultaneously. Default: Enabled

Add Button Click the Add button to add a host to the list of hosts that will be receiving communication from the serial device connected to the IOLAN.

See Adding/Editing a Multihost Entry on page 81 for more information.

Edit Button Highlight an existing host and click the Edit button to edit a host in the list of hosts that will be receiving communication from the serial device connected to the IOLAN.

Delete Button Highlight an existing host and click the Edit button to edit a host in the list of hosts that will be receiving communication from the serial device connected to the IOLAN.

Define a primary host and backup...

When this option is enabled, you need to define a primary host that the serial device connected to this serial port will communicate to and a backup host, in the event that the IOLAN looses communication to the primary host. The IOLAN will first establish a connection to the primary host. Should the connection to the primary host be lost (or never established), the IOLAN will establish a connection the backup host. Once connected to the backup, the IOLAN will attempt to re-establish a connection to the Primary host, once this is successfully done, it gracefully shuts down the backup connection. Default: Disabled

Serial Port Profiles

Page 81 of the Perle Systems TS2 user manual — TruePort Profile
Page 81 · click to enlarge
Page 81

Primary Host Specify a preconfigured host that the serial device will communicate to through the IOLAN. Default: None

TCP Port Specify the TCP port that the IOLAN will use to communicate to the Primary Host. Default: 0

Backup Host Specify a preconfigured host that the serial device will communicate to through the IOLAN if the IOLAN cannot communicate with the Primary Host. Default: None

TCP Port Specify the TCP port that the IOLAN will use to communicate to the Backup Host. Default: 10000

Adding/Editing a Multihost Entry When you click the Add or Edit button, the Host Entry window appears. The hosts in the multihost list must already be defined. If you add a host that was defined with its fully qualified domain name (FQDN), it must be resolvable by your configured DNS server.

Perle Systems TS2 — TruePort Profile diagram (page 81)
Fig. 48 · TruePort Profile

Configure the following parameters:

Host Name Specify the preconfigured host that will be in the multihost list. Default: None

TCP Port Specify the TCP port that the IOLAN will use to communicate to the Primary Host. Default: 10000 + serial port number - 1 (so serial port 2 defaults to 10001)

Serial Port Profiles

Page 82 of the Perle Systems TS2 user manual — TruePort Profile
Page 82 · click to enlarge
Page 82

Advanced Tab Field Descriptions The TruePort Advanced tab determines how the TruePort connection is initiated and then sets up the appropriate connection parameters.

Perle Systems TS2 — TruePort Profile diagram (page 82)
Fig. 49 · TruePort Profile

Configure the following parameters:

Signals high when...

When a TruePort line becomes active, this option has the following impact:

z TruePort Lite Mode—When enabled, the EIA-232 signals remain high (active) before, during, and after the TruePort session. When disabled, the EIA-232 signals remain low (inactive).

z TruePort Full Mode—During the session, the TruePort client will be control the state of these signal before and after the connection. Default: Enabled

Enable Message of the Day (MOTD)

Enables/disables the display of the message of the day. Default: Disabled

Idle Timeout Use this timer to close a connection because of inactivity. When the Idle Timeout expires, the IOLAN will end the connection. Default: 0 seconds so the port will never timeout Range: 0-4294967 seconds (about 49 days)

Session Timeout Use this timer to forcibly close the session/connection when the Session Timeout expires. Default: 0 seconds so the port will never timeout Range: 0-4294967 seconds (about 49 days)

Dial In If the device is remote and will be dialing in via modem or ISDN TA, enable this parameter. Default: Disabled

Dial Out If you want the modem to dial a number when the serial port is started, enable this parameter. Default: Disabled

Serial Port Profiles

Page 83 of the Perle Systems TS2 user manual — TCP Sockets Profile
Page 83 · click to enlarge
Page 83

Dial Timeout The number of seconds the IOLAN will wait to establish a connection to a remote modem. Range: 1-99 Default: 45 seconds

Dial Retry The number of times the IOLAN will attempt to re-establish a connection with a remote modem. Range: 0-99 Default: 2

Modem The name of the predefined modem that is used on this line.

Phone The phone number to use when Dial Out is enabled.

TCP Sockets Profile

Overview The TCP Socket profile allows for a serial device to communicate over a TCP network. The TCP connection can be initiated from a host on the network and/or a serial device. This is typically used with an application on a Workstation or Server that communicates to a device using a specific TCP socket. This is often referred to as a RAW connection.

Functionality The TCP Sockets profile permits a raw connection to be established in either direction, meaning that the connection can be initiated by either the Workstation/Server or the IOLAN.

Perle Systems TS2 — TCP Sockets Profile diagram (page 83)
Fig. 50 · TCP Sockets Profile

Serial Port Profiles

Page 84 of the Perle Systems TS2 user manual — General Tab Field Descriptions
Page 84 · click to enlarge
Page 84

General Tab Field Descriptions

Perle Systems TS2 — General Tab Field Descriptions diagram (page 84)
Fig. 51 · General Tab Field Descriptions

Configure the following parameters:

When enabled, the IOLAN listens for a connection to be established by the Workstation/Server on the network. Default: Enabled

TCP Port The TCP port that the IOLAN will use to listen for incoming connections. Default: 10000 plus the serial port number, so serial port 2 would have a default of 10002

Allow Multiple Hosts to Connect

When this option is enabled, multiple hosts can connect to the serial device that is connected to this serial port. Default: Disabled

Connect To When enabled, the IOLAN initiates communication to the Workstation/Server. Default: Disabled

Host Name The configured host that the IOLAN will connect to.

TCP Port The TCP Port that the IOLAN will use to communicate to the client. Default: 0

Connect to Multiple Hosts

When enabled, allows a serial device connected to this serial port to communicate to multiple hosts. Default: Disabled

Define Additional Hosts Button

Click this button to define the hosts that this serial port will connect to. This button is also used to define the Primary/Backup host functionality.

If the serial port hardware parameters have been setup to monitor DSR or DCD, the host session will be started once the signals are detected. If no hardware signals are being monitored, the IOLAN will initiate the session immediately after being powered up. Default: Enabled

Serial Port Profiles · Listen for Connection · Initiate Connection Automatically

Page 85 of the Perle Systems TS2 user manual — TCP Sockets Profile
Page 85 · click to enlarge
Page 85

Initiate Connection When any data is received

Initiates a connection to the specified host when any data is received on the serial port. Default: Disabled

Initiate Connection When <hex value> is received

Initiates a connection to the specified host only when the specified character is received on the serial port. Default: Disabled

Permit Connections in Both Directions

When this option is enabled, the connection can be initiated by either the IOLAN or a host. Default: Disabled

Adding/Editing Additional Hosts You can define a list of hosts that the serial device will communicate to or a primary/backup host.

Perle Systems TS2 — TCP Sockets Profile diagram (page 85)
Fig. 52 · TCP Sockets Profile

Configure the following parameters:

Define additional hosts to connect to

When this option is enabled, you can define up to 49 hosts that the serial device connected to this serial port will attempt communicate to. With this mode of operation, the IOLAN will connect to multiple hosts simultaneously. Default: Enabled

Add Button Click the Add button to add a host to the list of hosts that will be receiving communication from the serial device connected to the IOLAN.

Edit Button Highlight an existing host and click the Edit button to edit a host in the list of hosts that will be receiving communication from the serial device connected to the IOLAN.

Delete Button Click the Delete button to delete a host to the list of hosts that will be receiving communication from the serial device connected to the IOLAN.

Serial Port Profiles

Page 86 of the Perle Systems TS2 user manual — TCP Sockets Profile
Page 86 · click to enlarge
Page 86

Define a primary host and backup...

When this option is enabled, you need to define a primary host that the serial device connected to this serial port will communicate to and a backup host, in the event that the IOLAN looses communication to the primary host. The IOLAN will first establish a connection to the primary host. Should the connection to the primary host be lost (or never established), the IOLAN will establish a connection the backup host. Once connected to the backup, the IOLAN will attempt to re-establish a connection to the Primary host, once this is successfully done, it gracefully shuts down the backup connection. Default: Disabled

Primary Host Specify a preconfigured host that the serial device will communicate to through the IOLAN. Default: None

TCP Port Specify the TCP port that the IOLAN will use to communicate to the Primary Host. Default: 0

Backup Host Specify a preconfigured host that the serial device will communicate to through the IOLAN if the IOLAN cannot communicate with the Primary Host. Default: None

TCP Port Specify the TCP port that the IOLAN will use to communicate to the Backup Host. Default: 10000

Adding/Editing a Multihost Entry When you click the Add or Edit button, the Host Entry window appears. The hosts in the multihost list must already be defined (see Host Table on page 64 to learn how to create a host). If you add a host that was defined with its fully qualified domain name (FQDN), it must be resolvable by your configured DNS server.

Perle Systems TS2 — TCP Sockets Profile diagram (page 86)
Fig. 53 · TCP Sockets Profile

Configure the following parameters:

Host Name Specify the preconfigured host that will be in the multihost list. Default: None

TCP Port Specify the TCP port that the IOLAN will use to communicate to the Host. Default: 0

Serial Port Profiles

Page 87 of the Perle Systems TS2 user manual — Advanced Tab Field Descriptions
Page 87 · click to enlarge
Page 87

Advanced Tab Field Descriptions

Perle Systems TS2 — Advanced Tab Field Descriptions diagram (page 87)
Fig. 54 · Advanced Tab Field Descriptions

Configure the following parameters:

Authenticate User Enables/disables login/password authentication for users connecting from the network. Default: Disabled

Enables a per-connection TCP keepalive feature. After the configured number of seconds, the connection will send a gratuitous ACK to the network peer, thus either ensuring the connection stays active OR causing a dropped connection condition to be recognized. This parameter needs to be used in conjunction with Monitor Connection Status Interval parameter found in the Serial, Advanced, Advanced Settings tab. The interval determines how long the IOLAN will wait during inactivity before "testing" the connection. It should be noted that if a network connection is accidentally dropped, it can take as long as the specified interval before anyone can reconnect to the serial port. Default: Disabled

Enable Message of the Day (MOTD)

Enables/disables the display of the message of the day. Default: Disabled

Idle Timeout Use this timer to close a connection because of inactivity. When the Idle Timeout expires, the IOLAN will end the connection. Default: 0 seconds so the port will never timeout Range: 0-4294967 seconds (about 49 days)

Session Timeout Use this timer to forcibly close the session/connection when the Session Timeout expires. Default: 0 seconds so the port will never timeout Range: 0-4294967 seconds (about 49 days)

Dial In If the device is remote and will be dialing in via modem or ISDN TA, enable this parameter. Default: Disabled

Serial Port Profiles · Enable TCP Keepalive

Page 88 of the Perle Systems TS2 user manual — UDP Sockets Profile
Page 88 · click to enlarge
Page 88

Dial Out If you want the modem to dial a number when the serial port is started, enable this parameter. Default: Disabled

Dial Timeout The number of seconds the IOLAN will wait to establish a connection to a remote modem. Range: 1-99 Default: 45 seconds

Dial Retry The number of times the IOLAN will attempt to re-establish a connection with a remote modem. Range: 0-99 Default: 2

Modem The name of the predefined modem that is used on this line.

Phone The phone number to use when Dial Out is enabled.

UDP Sockets Profile

Overview When you configure UDP, you are setting up a range of IP addresses and the port numbers that you will use to send UDP data to or receive UDP data from.

Functionality The UDP profile configures a serial port to broadcast UDP data to systems and/or receive UDP data from systems.

Perle Systems TS2 — UDP Sockets Profile diagram (page 88)
Fig. 55 · UDP Sockets Profile

Serial Port Profiles

Page 89 of the Perle Systems TS2 user manual — UDP Sockets Profile
Page 89 · click to enlarge
Page 89

An example UDP configuration is described based on the following window.

Perle Systems TS2 — UDP Sockets Profile diagram (page 89)
Fig. 56 · UDP Sockets Profile

The UDP configuration window, taken from the DeviceManager, is configured to:

z UDP Entry 1 All hosts that have an IP address that falls within the range of 172.16.1.1 to 172.16.1.25 and listen to Port 33001 will be sent the data from the serial device in UDP format. The serial device will only receive UDP data from the hosts in that range with a source Port of 33001. The IOLAN will listen for data on the port value configured in the Listen for connections on UDP port parameter.

z UDP Entry 2 All UDP data received from hosts that have an IP address that falls within the range of 172.16.1.20 to 172.16.1.50 and Port 33010 will be sent to the serial device. The IOLAN will not send any data received on its serial port.

z UDP Entry 3 All hosts that have an IP Address that falls within the range of 172.16.1.75 to 172.16.1.80 and who listen to Port 33009 will receive UDP data from the serial device. The IOLAN will listen for messages on the port value configured in the Listen for connections on UDP port parameter. No UDP data will be sent to the serial device.

z UDP Entry 4 This entry is disabled since Direction is set to Disabled.

Serial Port Profiles

Page 90 of the Perle Systems TS2 user manual — General Tab Field Descriptions
Page 90 · click to enlarge
Page 90

General Tab Field Descriptions

Perle Systems TS2 — General Tab Field Descriptions diagram (page 90)
Fig. 57 · General Tab Field Descriptions

Configure the following parameters:

Listen for connections on UDP port

The IOLAN will listen for UDP packets on the specified port. Default: 1000+ (for example, 10001 for serial port 1)

Direction The direction in which information is received or relayed:

z Disabled—UDP service not enabled.

z LAN to Serial—UDP Port can be set to Auto-learn or Port. The IOLAN will listen on port value configured in the Listen for connections on UDP port parameter for messages coming from the learned or configured port.

z Serial to LAN—UDP Port can be set to Port only. The IOLAN will listen on the port value configured in the Listen for connections on UDP port parameter and will send to the configured port.

z Both—Messages are relayed in both directions. UDP Port can be set to Auto-learn or Port. For messages coming from the LAN to the serial device, IOLAN will listen on port value configured in the Listen for connections on UDP port parameter for messages coming from the learned or configured port. For messages going from the serial device to the LAN, the IOLAN will listen on the port value configured in the Listen for connections on UDP port parameter and will send to the configured or learned (if Auto-learn is enabled, the IOLAN must receive a UDP message before it can send one, since the port must first be ’learned’) port.

Start IP Address The first host IP address in the range of IP addresses (for IPV4 or IPV6) that the IOLAN will listen for messages from and/or send messages to.

End IP Address The last host IP address in the range of IP addresses (for IPV4, not required for IPV6) that the IOLAN will listen for messages from and/or send messages to.

Autolearn The IOLAN will only listen to the first port that it receives a UDP packet from. Applicable when Direction is set to LAN to Serial or Both.

Serial Port Profiles

Page 91 of the Perle Systems TS2 user manual — Terminal Profile
Page 91 · click to enlarge
Page 91

Any Port The IOLAN will receive messages from any port sending UDP packets. Applicable when Direction is set to LAN to Serial.

Port The port that the IOLAN will use to relay messages to servers/hosts. This option works with any Direction except Disabled. The IOLAN will listen for UDP packets on the port configured by the Listen for connections on UDP port parameter. Default: 0 (zero)

Terminal Profile

Overview The Terminal profile allows network access from a terminal connected to the IOLAN’s serial port. This profile is used to access pre-defined hosts on the network from the terminal.

Functionality This profile can be setup in two ways:

1. The user can be required to log into the IOLAN and then a connection to a host can be established.
2. The user connecting to the serial port will be directly connected a host.

Serial Port Profiles

Page 92 of the Perle Systems TS2 user manual — General Tab Field Descriptions
Page 92 · click to enlarge
Page 92

General Tab Field Descriptions

Perle Systems TS2 — General Tab Field Descriptions diagram (page 92)
Fig. 58 · General Tab Field Descriptions

Configure the following parameters:

Terminal Type Specifies the type of terminal connected to the line. Data Options:

z VT320 (specifically supporting VT320-7)

z HP700 (specifically supporting HP700/44)

z Term1, Term2, Term3 (user-defined terminals) Default: Dumb

Require Login When users access the IOLAN through the serial port, they must be authenticated using the local user database. Default: Enabled

User Service Settings Button

After a user has been successfully authenticated, the IOLAN will connect to the specified host using the specified protocol according to:

z the User Service parameter for locally configured users

z the Default User Service parameter for users who are externally authenticated

See User Service Settings on page 95 for field descriptions of the various User Service Settings.

Connect to Remote System

When the serial port is started, the IOLAN will initiate a connection to the specified host using the specified protocol. With this option, user authentication will not be performed by the IOLAN. Default: Disabled

Show 7 more labels / short text on this page
Serial Port Profiles · z Dumb · z WYSE60 · z VT100 · z ANSI · z TVI925 · z IBM3151TE
Page 93 of the Perle Systems TS2 user manual — Advanced Tab Field Descriptions
Page 93 · click to enlarge
Page 93

Protocol Specify the protocol that will be used to connect to the specified host. Default: Telnet

Settings Button Click this button to define the settings for the protocol that will be used to connect the user to the specified host.

Host Name The configured host that the IOLAN will connect to.

TCP Port The TCP Port that the IOLAN will use to connect to the host. Default: 23

Automatically If the serial port hardware parameters have been setup to monitor DSR or DCD, the host session will be started once the signals are detected. If no hardware signals are being monitored, the IOLAN will initiate the session immediately after being powered up. Default: Enabled

When any data is received

Initiates a connection to the specified host when any data is received on the serial port. Default: Disabled

When <hex value> is received

Initiates a connection to the specified host only when the specified character is received on the serial port. Default: Disabled

Advanced Tab Field Descriptions

Perle Systems TS2 — Advanced Tab Field Descriptions diagram (page 93)
Fig. 59 · Advanced Tab Field Descriptions

Configure the following parameters:

Enable Message of the Day (MOTD)

Enables/disables the display of the message of the day. Default: Disabled

Serial Port Profiles

Page 94 of the Perle Systems TS2 user manual — Terminal Profile
Page 94 · click to enlarge
Page 94

Reset Terminal on disconnect

When enabled, resets the terminal definition connected to the serial port when a user logs out. Default: Disabled

Allow Port Locking When enabled, the user can lock his terminal with a password using the

Hotkey Prefix (default Ctrl-a) ^a l (lowercase L). The IOLAN prompts the user for a password and a confirmation. Default: Disabled

Hotkey Prefix The prefix that a user types to lock a serial port or redraw the Menu. Data Range:

z ^a l—(Lowercase L) Locks the serial port until the user unlocks it. The user is prompted for a password (any password, excluding spaces) and locks the serial port. Next, the user must retype the password to unlock the serial port.

z ^r—When you switch from a session back to the Menu, the screen may not be redrawn correctly. If this happens, use this command to redraw it properly. This is always Ctrl R, regardless of the Hotkey Prefix. You can use the Hotkey Prefix key to lock a serial port only when the Allow Port Locking parameter is enabled. Default: Hex 01 (Ctrl-a, ^a)

Idle Timeout Use this timer to close a connection because of inactivity. When the Idle Timeout expires, the IOLAN will end the connection. Default: 0 seconds so the port will never timeout Range: 0-4294967 seconds (about 49 days)

Session Timeout Use this timer to forcibly close the session/connection when the Session Timeout expires. Default: 0 seconds so the port will never timeout Range: 0-4294967 seconds (about 49 days)

Dial Timeout The number of seconds the IOLAN will wait to establish a connection to a remote modem. Range: 1-99 Default: 45 seconds

Dial Retry The number of times the IOLAN will attempt to re-establish a connection with a remote modem. Range: 0-99 Default: 2

Dial In If the device is remote and will be dialing in via modem or ISDN TA, enable this parameter. Default: Disabled

Dial Out If you want the modem to dial a number when the serial port is started, enable this parameter. Default: Disabled

Serial Port Profiles

Page 95 of the Perle Systems TS2 user manual — User Service Settings
Page 95 · click to enlarge
Page 95

User Service Settings

Login Settings These settings apply to users who are accessing the network from a terminal connected to the IOLAN’s serial port. The Telnet settings take effect when the connection method is defined in the user’s profile.

Perle Systems TS2 — User Service Settings diagram (page 95)
Fig. 60 · User Service Settings

Configure the following parameters:

Limit Connection to User

Makes the serial port dedicated to the specified user. The user won’t need to enter their login name - just their password.

Initial Mode Specifies the initial interface a user navigates when logging into the serial port. Data Options: Menu, Command Line Default: Command Line

Terminal Pages The number of video pages the terminal supports. Range: 1-7 Default: 5 pages

Telnet Settings The Telnet settings apply when the User Service is set to Telnet or the Terminal profile specifies a Telnet connection to a host.

Perle Systems TS2 — User Service Settings diagram (page 95)
Fig. 61 · User Service Settings

Configure the following parameters:

Terminal Type Type of terminal attached to this serial port; for example, ANSI or WYSE60.

Enable Local Echo Toggles between local echo of entered characters and suppressing local echo.

Local echo is used for normal processing, while suppressing the echo is convenient for entering text that should not be displayed on the screen, such as passwords. This parameter can be used only when Enable Line Mode is enabled. Default: Disabled

Serial Port Profiles

Page 96 of the Perle Systems TS2 user manual — User Service Settings
Page 96 · click to enlarge
Page 96

Enable Line Mode When enabled, keyboard input is not sent to the remote host until Enter is

pressed, otherwise input is sent every time a key is pressed. Default: Disabled

Map CR to CRLF When enabled, maps carriage returns (CR) to carriage return line feed (CRLF). Default: Disabled

Interrupt Defines the interrupt character. Typing the interrupt character interrupts the current process. This value is in hexadecimal. Default: 3 (ASCII value ^C)

Quit Defines the quit character. Typing the quit character closes and exits the current telnet session. This value is in hexadecimal. Default: 1c (ASCII value FS)

EOF Defines the end-of-file character. When Enable Line Mode is enabled, entering the EOF character as the first character on a line sends the character to the remote host. This value is in hexadecimal. Default: 4 (ASCII value ^D)

Erase Defines the erase character. When Line Mode is Off, typing the erase character erases one character. This value is in hexadecimal. Default: 8 (ASCII value ^H)

Echo Defines the echo character. When Line Mode is On, typing the echo character echoes the text locally and sends only completed lines to the host. This value is in hexadecimal. Default: 5 (ASCII value ^E)

Escape Defines the escape character. Returns you to the command line mode. This value is in hexadecimal. Default: 1d (ASCII value GS)

Serial Port Profiles

Page 97 of the Perle Systems TS2 user manual — IOLAN
Page 97 · click to enlarge
Page 97

Serial Tunneling Profile

Overview The Serial Tunneling profile allows two IOLANs to be connected back-to-back over the network to establish a virtual link between two serial ports based on RFC 2217.

Functionality The serial device that initiates the connection is the Tunnel Client and the destination is the Tunnel Server, although once the serial communication tunnel has been successfully established, communication can go both ways.

Perle Systems TS2 — Serial Tunneling Profile diagram (page 97)
Fig. 62 · Serial Tunneling Profile

A more detailed implementation of the Serial Tunneling profile is as follows:

Client Tunnel Server Tunnel

IOLAN

IOLAN

The Server Tunnel will also support Telnet Com Port Control protocol as detailed in RFC 2217.

IOLAN

The IOLAN serial port signals will also follow the signals on the other serial port. If one serial port receives DSR then it will raise DTR on the other serial port. If one serial port receives CTS then it will raise RTS on the other serial port. The CD signal is ignored.

Show 11 more labels / short text on this page
Serial Port Profiles · Serial · Serial · Network · perle · perle · Serial · Network · Server Tunnel · perle · Running 2217 Application
Page 98 of the Perle Systems TS2 user manual — General Tab Field Descriptions
Page 98 · click to enlarge
Page 98

General Tab Field Descriptions

Perle Systems TS2 — General Tab Field Descriptions diagram (page 98)
Fig. 63 · General Tab Field Descriptions

Configure the following parameters:

Act As Tunnel Server

The IOLAN will listen for an incoming connection request on the specified Internet Address on the specified TCP Port. Default: Enabled

TCP Port The TCP port that the IOLAN will listen for incoming connection on. Default: 10000+serial port number; so serial port 2 is 10002.

Enables a per-connection TCP keepalive feature. After the configured number of seconds, the connection will send a gratuitous ACK to the network peer, thus either ensuring the connection stays active OR causing a dropped connection condition to be recognized. This parameter needs to be used in conjunction with Monitor Connection Status Interval parameter found in the Serial, Advanced, Advanced Settings tab. The interval determines how long the IOLAN will wait during inactivity before "testing" the connection. It should be noted that if a network connection is accidentally dropped, it can take as long as the specified interval before anyone can reconnect to the serial port. Default: Disabled

Act as Tunnel Client

The IOLAN will initiate the connection the Tunnel Server. Default: Disabled

Host Name A preconfigured host name that is associated with the IP address of the Tunnel Server.

TCP Port The TCP port that the IOLAN will use to connect to the Tunnel Server. Default: 10000+serial port number; so serial port 5 is 10005.

Serial Port Profiles · Enable TCP Keepalive

Page 99 of the Perle Systems TS2 user manual — Overview
Page 99 · click to enlarge
Page 99

Virtual Modem Profile

Overview

Virtual Modem (Vmodem) is a feature of the IOLAN that provides a modem interface to a serial device. It will respond to AT commands and provide signals in the same way that a serially attached modem would. This feature is typically used when you are replacing dial-up modems with the IOLAN in order to provide Ethernet network connectivity.

Functionality The serial port will behave in exactly the same fashion as it would if it were connected to a modem. Using AT commands, it can configure the modem and the issue a dial-out request (ATTD). The IOLAN will then translate the dial request into a TCP connection and data will be begin to flow in both directions. The connection can be terminated by ’hanging’ up the phone line.

You can also manually start a connection by typing ATD<ip_address>,<port_number> and end the connection by typing +++ATH. The ip_address can be in IPv4 or IPv6 formats and is the IP address of the receiver. For example, ATD123.34.23.43,10001 or you can use ATD12303402304310001, without any punctuation (although you do need to add zeros where there are not three digits presents, so that the IP address is 12 digits long).

Perle Systems TS2 — Overview diagram (page 99)
Fig. 64 · Overview

Serial Port Profiles

Page 100 of the Perle Systems TS2 user manual — General Tab Field Descriptions
Page 100 · click to enlarge
Page 100

General Tab Field Descriptions

Perle Systems TS2 — General Tab Field Descriptions diagram (page 100)
Fig. 65 · General Tab Field Descriptions

Configure the following parameters:

Connect Automatically At Startup

When enabled, automatically establishes the virtual modem connection when the serial port becomes active. Default: Enabled

Host Name The preconfigured target host name.

TCP Port The port number the target host is listening on for messages. Default: 0 (zero)

Connect Manually Via AT Command

When enabled, the virtual modem requires an AT command before it establishes a connection. Specify this option when your modem application sends a phone number or other AT command to a modem. The serial device can supply an IP address directly or it can provide a phone number that will be translated into an IP address by the IOLAN using the mapping table. Default: Disabled

Phone Number to Host Mapping Button

When your modem application provides a phone number in an AT command string, you can map that phone number to the destination host.

See Phone Number to Host Mapping on page 102 for information about the window that appears when you click this button.

Send Connection Status As

When enabled, the connection success/failure indication strings are sent to the connected device, otherwise these indications are suppressed. This option also determines the format of the connection status results that are generated by the virtual modem. Default: Enabled

Verbose String When enabled, the connection status is sent by text strings to the connected device. Default: Disabled

Success String String that is sent to the serial device when a connection succeeds. Default: CONNECT , for example, CONNECT 9600

Failure String String that is sent to the serial device when a connection fails. Default: NO CARRIER

Serial Port Profiles

Page 101 of the Perle Systems TS2 user manual — Advanced Tab Field Descriptions
Page 101 · click to enlarge
Page 101

Numeric Codes When enabled, the connection status is sent to the connected device using the following numeric codes:

z 1 Successfully Connected

z 2 Failed to Connect

z 4 Error DefaultEnabled

Advanced Tab Field Descriptions

Perle Systems TS2 — Advanced Tab Field Descriptions diagram (page 101)
Fig. 66 · Advanced Tab Field Descriptions

Configure the following parameters:

Echo characters in command mode

When enabled, echoes back characters that are typed in (equivalent to ATE0/ATE1 commands). Default: Disabled

DTR Signal Always On

Specify this option to make the DTR signal always act as a DTR signal. Default: Enabled

DTR Signal Acts as DCD

Specify this option to make the DTR signal always act as a DCD signal. Default: Disabled

DTR Signal Acts as RI

Specify this option to make the DTR signal always act as a RI signal. Default: Disabled

RTS Signal Always On

Specify this option to make the RTS signal always act as a RTS signal. Default: Enabled

RTS Signal Acts as DCD

Specify this option to make the RTS signal always act as a DCD signal. Default: Disabled

RTS Signal Acts as RI

Specify this option to make the RTS signal always act as a RI signal. Default: Disabled

Serial Port Profiles

Page 102 of the Perle Systems TS2 user manual — Virtual Modem Profile
Page 102 · click to enlarge
Page 102

You can specify additional virtual modem commands that will affect how virtual modem starts. The following commands are supported: ATQn, ATVn, ATEn, +++ATH, ATA, ATI0, ATI3, ATS0, AT&Z1, AT&Sn, AT&Rn, AT&Cn, AT&F, ATS2, ATS12, ATO (ATD with no phone number), and ATDS1.

See Appendix A, Virtual Modem AT Commands on page 185 for a more detailed explanation of the support initialization commands.

Enable Message of the Day (MOTD)

When enabled, displays the Message of the Day (MOTD) when a successful virtual modem connection is made. Default: Disabled

AT Command Response Delay

The amount of time, in milliseconds, before an AT response is sent to the requesting device. Default: 250 ms

Phone Number to Host Mapping If your modem application dials using a phone number, you can add an entry in the Phone Number to Host Mapping window that can be accessed by all serial ports configured as Virtual Modem. You need to enter the phone number sent by your modem application and the IOLAN IP address and TCP Port that will be receiving the ’call.’ The DS1 supports up to 4 entries and the TS2 supports up to 8 entries.

Perle Systems TS2 — Virtual Modem Profile diagram (page 102)
Fig. 67 · Virtual Modem Profile

The following buttons are available:

Add Button Click the Add button to display a window that allows you to configure the phone number or AT command your modem application sends and the IOLAN’s IP address and TCP port number that is receiving the call.

Edit Button Click on a phone number entry and click the Edit button to change any values configured for the phone number.

Delete Button Click on a phone number entry and click the Delete button to remove it from the phone number list.

Serial Port Profiles · Additional modem initialization

Page 103 of the Perle Systems TS2 user manual — Control Signal I/O Profile
Page 103 · click to enlarge
Page 103

VModem Phone Number Entry Create an entry in the Phone Number to Host Mapping window.

Perle Systems TS2 — Control Signal I/O Profile diagram (page 103)
Fig. 68 · Control Signal I/O Profile

Configure the following parameters:

Phone Number Specify the phone number your modem application sends to the modem. Note: The IOLAN does not validate the phone number, so it must be entered in the exact way the application will send it. For example, if you enter 555-1212 in this table and the application sends 5551212, the IOLAN will not match the two numbers.

Host IP Address Specify the IP address of the IOLAN that is receiving the virtual modem connection.

TCP Port Specify the TCP Port on the IOLAN that is set to receive the virtual modem connection. Default: 0

Control Signal I/O Profile

Overview The Control Signal I/O profile is only available on IOLAN I/O models. When you configure a serial port for Control Signal I/O, you are using the DSR, DCD, CTS, DTR, and RTS serial pins for I/O channel Digital Input (DSR, DCD, and CTS) or Digital Output (DTR and RTS).

Functionality The Control Signal I/O profile enables the use of the EIA-232 serial port pins to be used as assigned Digital Inputs or Digital Outputs.

Perle Systems TS2 — Control Signal I/O Profile diagram (page 103)
Fig. 69 · Control Signal I/O Profile

Serial Port Profiles

Page 104 of the Perle Systems TS2 user manual — Input Signal Field Descriptions
Page 104 · click to enlarge
Page 104

General Tab Field Descriptions The General tab displays the signal pins. This window is also used to enable/disable the signal pins.

Perle Systems TS2 — Control Signal I/O Profile diagram (page 104)
Fig. 70 · Control Signal I/O Profile

Highlight a signal and then click the Edit button to configure the signal pin’s parameters.

Input Signal Field Descriptions

Perle Systems TS2 — Input Signal Field Descriptions diagram (page 104)
Fig. 71 · Input Signal Field Descriptions

Configure the following parameters:

Description Provide a description of the channel, making it easier to identify. Data Options: Maximum 20 characters, including spaces

Latch Latches (remembers) the activity transition (active to inactive or inactive to active). Data Options: None, Inactive-to-Active, Active-to-Inactive Default: None

Invert Signal When enabled, inverts the actual condition of the I/O signal in the status; therefore, an inactive status will be displayed as active. Default: Disabled

Serial Port Profiles

Page 105 of the Perle Systems TS2 user manual — Output Signal Field Descriptions
Page 105 · click to enlarge
Page 105

Trigger When the trigger condition is met, triggers the specified alarm action. Data Options:

z Disabled—No alarm settings. This is the default.

z Inactive—When the expected Digital input is active, going inactive will trigger an alarm.

z Active—When the expected Digital input is inactive, going active will trigger an alarm. Default: Disabled

Auto Clear Mode When enabled, automatically clears the alarm when the trigger condition changes; for example, if the Trigger is Inactive and the alarm is triggered, once the input becomes active again, the alarm will automatically be cleared Default: Enabled

When enabled, a triggered alarm must be manually cleared. Default: Disabled

Syslog When enabled, sends a message to syslog when an alarm is triggered or cleared. The syslog entry includes the severity level and the value that caused the alarm to trigger or clear. The syslog message is associated with Level Critical. Default: Disabled

SNMP When enabled, sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the severity level and whether the alarm was triggered or cleared. Default: Disabled

Output Signal Field Descriptions

Perle Systems TS2 — Output Signal Field Descriptions diagram (page 105)
Fig. 72 · Output Signal Field Descriptions

Configure the following parameters:

Description Provide a description of the channel, making it easier to identify. Data Options: Maximum 20 characters, including spaces

Serial Port Profiles · Manual Clear Mode

Page 106 of the Perle Systems TS2 user manual — Modbus Gateway Profile
Page 106 · click to enlarge
Page 106

Failsafe Action When there has been no I/O activity within the specified time (set in the I/O Interfaces, Settings on the Failsafe Timer tab) and the Failsafe Timer is triggered. Data Options:

z None—The state of the Digital/Relay output remains the same, no change.

z Activate Output—Activates the channel.

z Deactivate Output—Deactivates the channel. Default: None

Modbus Gateway Profile

Overview Each serial port can be configured as either a Modbus Master gateway or a Modbus Slave gateway, depending on your configuration and requirements. If your model supports I/O, see Modbus I/O Access on page 153 for more information on using the Modbus protocol to access I/O data.

Functionality The Modbus Gateway profile configures a serial port to act as a Modbus Master Gateway or a Modbus Slave Gateway.

Perle Systems TS2 — Modbus Gateway Profile diagram (page 106)
Fig. 73 · Modbus Gateway Profile

Serial Port Profiles

Page 107 of the Perle Systems TS2 user manual — General Tab Field Descriptions
Page 107 · click to enlarge
Page 107

General Tab Field Descriptions

Perle Systems TS2 — General Tab Field Descriptions diagram (page 107)
Fig. 74 · General Tab Field Descriptions

Configure the following parameters:

Mode Specify how the Modbus Gateway is defined on the serial port. Data Options:

z Modbus Master—Typically, the Modbus Master is connected to the Serial Port and is communicating to Modbus Slaves on the network.

z Modbus Slave—Typically, the Modbus Master is accessing the IOLAN through the network to communicated to Modbus Slaves connected to the IOLAN’s Serial Ports. Default: Modbus Master Gateway

Destination Slave IP Mappings Button

Click this button to launch the Destination Slave IP Settings window, where you can configure the TCP/Ethernet Modbus Slaves that the Modbus Master on the Serial Port will communicate with.

UID Range You can specify a range of UIDs (1-247), in addition to individual UIDs. Field Format: Comma delimited; for example, 2-35, 50, 100-103

Advanced Slave Settings Button

Click this button to configure global Modbus Slave settings.

Modbus/RTU Select this option when the Modbus/RTU protocol is being used for communication between the Modbus Master and Slave. Default: Enabled

Modbus/ASCII Select this option when Modbus/ASCII protocol is being used for communication between the Modbus Master and Slave. Default: Disabled

Append CR/LF When Modbus/ASCII is selected, adds a CR/LF to the end of the transmission; most Modbus devices require this option. Default: Enabled

Serial Port Profiles

Page 108 of the Perle Systems TS2 user manual — Advanced Field Descriptions
Page 108 · click to enlarge
Page 108

Advanced Field Descriptions

Perle Systems TS2 — Advanced Field Descriptions diagram (page 108)
Fig. 75 · Advanced Field Descriptions

Configure the following parameters:

Idle Timeout Use this timer to close a connection because of inactivity. When the Idle Timeout expires, the IOLAN will end the connection. Range: 0-4294967 seconds (about 49 days) Default: 0 (zero), which does not timeout, so the connection is permanently open.

Click this button to launch the Destination Slave IP Settings window, where you can configure the TCP/Ethernet Modbus Slaves that the Modbus Master on the Serial Port will communicate with.

Character Timeout Used in conjunction with the Modbus RTU protocol, specifies how long to

wait, in milliseconds, after a character to determine the end of frame. Range: 10-10000 Default: 30 ms

Message Timeout Time to wait, in milliseconds, for a response message from a Modbus TCP or serial slave (depending if the Modbus Gateway is a Master Gateway or Slave Gateway, respectively) before sending a Modbus exception. Range: 10-10000 Default: 1000 ms

Serial Port Profiles · Enable Modbus Exceptions

Page 109 of the Perle Systems TS2 user manual — Adding/Editing Modbus Slave IP Settings
Page 109 · click to enlarge
Page 109

Modbus Slave IP Settings Field Descriptions This window is used to configure the Modbus Slaves.

Perle Systems TS2 — Modbus Gateway Profile diagram (page 109)
Fig. 76 · Modbus Gateway Profile

The following buttons are available:

Add Button Adds an entry into the Modbus Destination Slave IP Settings table.

Edit Button Edits an entry in the Modbus Destination Slave IP Settings table.

Delete Button Deletes an entry from the Modbus Destination Slave IP Settings table.

Adding/Editing Modbus Slave IP Settings

Perle Systems TS2 — Adding/Editing Modbus Slave IP Settings diagram (page 109)
Fig. 77 · Adding/Editing Modbus Slave IP Settings

Configure the following parameters:

UID Start When Destination is set to Host and you have sequential Modbus Slave IP addresses (for example, 10.10.10.1, 10.10.10.2, 10.10.10.3, etc.), you can specify a UID range and the IOLAN will automatically increment the last digit of the configured IP address. Therefore, you can specify a UID range of 1-100, and the IOLAN will route Master Modbus messages to all Modbus Slaves with IP addresses of 10.10.10.1 - 10.10.10.100. Range: 1-247 Default: 0 (zero)

Serial Port Profiles

Page 110 of the Perle Systems TS2 user manual — Modbus Gateway Profile
Page 110 · click to enlarge
Page 110

UID End When Destination is set to Host and you have sequential Modbus Slave IP addresses (for example, 10.10.10.1, 10.10.10.2, 10.10.10.3, etc.), you can specify a UID range and the IOLAN will automatically increment the last digit of the configured IP address. Therefore, you can specify a UID range of 1-100, and the IOLAN will route Master Modbus messages to all Modbus Slaves with IP addresses of 10.10.10.1 - 10.10.10.100. Range: 1-247 Default: 0 (zero)

Type Specify the configuration of the Modbus Slaves on the network. Data Options:

z Host—The IP address is used for the first UID specified in the range. The last octet in the IPv4 address is then incriminated for subsequent UID’s in that range. The Host option is not applicable for IPv6 addresses.

z Gateway—The Modbus Master Gateway will use the same IP address when connecting to all the remote Modbus slaves in the specified UID range. Default: Host

Start IP Address The IP address of the TCP/Ethernet Modbus Slave. Field Format: IPv4 or IPv6 (IPv6 format not supported for Destination Host)

End IP Address Displays the ending IP address of the TCP/Ethernet Modbus Slaves, based on the Start IP address and the UID range.

Protocol Specify the protocol that is used between the Modbus Master and Modbus Slave(s). Data Options: TCP or UDP Default: TCP

UDP/TCP Port The destination port of the remote Modbus TCP Slave that the IOLAN will connect to. Range: 0-65535 Default: 502

Serial Port Profiles

Page 111 of the Perle Systems TS2 user manual — Modbus Slave Advanced Settings Field Descriptions
Page 111 · click to enlarge
Page 111

Modbus Slave Advanced Settings Field Descriptions

Perle Systems TS2 — Modbus Slave Advanced Settings Field Descriptions diagram (page 111)
Fig. 78 · Modbus Slave Advanced Settings Field Descriptions

Configure the following parameters:

TCP/UDP Port The network port number that the Slave Gateway will listen on for both TCP and UDP messages. Default: 502

Next Request Delay A delay, in milliseconds, to allow serial slave(s) to re-enable receivers before

issuing next Modbus Master request. Range: 0-1000 Default: 50 ms

Enable Serial Modbus Broadcasts

When enabled, a UID of 0 (zero) indicates that the message will be broadcast to all Modbus Slaves. Default: Disabled

Request Queuing When enabled, allows multiple, simultaneous messages to be queued and processed in order of reception. Default: Enabled

Embedded When this option is selected, the address of the slave Modbus device is embedded in the message header. Default: Enabled

Remapped Used for single device/port operation. Older Modbus devices may not include a UID in their transmission header. When this option is selected, you can specify the UID that will be inserted into the message header for the Modbus slave device. This feature supersedes the Broadcast feature. Default: Disabled

Remap UID Specify the UID that will be inserted into the message header for the Slave Modbus serial device. Range: 1-247 Default: 1

Serial Port Profiles

Page 112 of the Perle Systems TS2 user manual — General Tab Field Description
Page 112 · click to enlarge
Page 112

Custom Application Profile

Overview The Custom App/Plugin profile is used in conjunction with custom applications created for the IOLAN by using the Perle SDK. See the SDK Programmer’s Guide (the SDK and guide are found on the Perle website at www.perle.com/downloads/index.shtml) for information about the functions that are supported. You must download the program and any ancillary files to the IOLAN and set the serial port to the Custom App/Plugin profile to actually run a custom application. You must also specify the program executable and any parameters you want to pass to the program in the Command Line field.

General Tab Field Description

Perle Systems TS2 — General Tab Field Description diagram (page 112)
Fig. 79 · General Tab Field Description

Configure the following parameter:

Command Line The name of the SDK program executable that has been already been downloaded to the IOLAN, plus any parameters you want to pass to the program.Use the shell CLI command as described in the SDK Programmer’s Guide to manage the files that you have downloaded to the IOLAN. For example, using sample outraw program, you would type:

outraw 192.168.2.1:10001 Acct:10001 if you were starting the application on a serial port. Field Format: Maximum of 80 characters

Serial Port Profiles

Page 113 of the Perle Systems TS2 user manual — Field Descriptions
Page 113 · click to enlarge
Page 113

Advanced

Advanced Serial Settings Tab

Overview Advanced serial port settings apply to all serial ports.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 113)
Fig. 80 · Field Descriptions

Configure the following parameters:

Flush Data Before Closing Serial Port

When enabled, deletes any pending data when a port is closed. Default: Disabled

Deny Multiple Network Connections

Allows only one network connection at a time per a serial port. Application accessing a serial port device across a network with get a connection (socket) refused until:

z All data from previous connections on that serial port has drained

z There are no other connections

z Up to a 1 second interconnection poll timer has expired This also enables a per-connection TCP keepalive feature. After approximately 3 minutes of network connection idle time, the connection will send a gratuitous ACK to the network peer, thus either ensuring the connection stays active OR causing a dropped connection condition to be recognized by all peer network connections. Applications using this feature need to be aware that there can be some considerable delay between a network disconnection and the port being available for the next connection attempt, allowing any data sent on prior connections to be transmitted out of the serial port. Application network retry logic needs to accommodate this feature. Default: Disabled

Monitor Connection Interval Status

Specify how often, in seconds, the IOLAN will send a TCP Keepalive to services that support TCP Keepalive. Default: 30 seconds

Advanced

Page 114 of the Perle Systems TS2 user manual — Modems Tab
Page 114 · click to enlarge
Page 114

Modems Tab

Overview You need to configure a modem if there is a modem connected to the IOLAN.

When you click on the Modems tab, you will see the following:

Perle Systems TS2 — Modems Tab diagram (page 114)
Fig. 81 · Modems Tab

If any modems have been configured, they will be displayed.

Adding/Editing a Modem You can add new modems or edit existing modems through the following window:

Perle Systems TS2 — Modems Tab diagram (page 114)
Fig. 82 · Modems Tab

Configure the following parameters:

Name The name of the modem. Restrictions: Do not use spaces.

Initialization String The initialization string of the modem; see your modem’s documentation.

Advanced

Page 115 of the Perle Systems TS2 user manual — Field Definitions
Page 115 · click to enlarge
Page 115

TruePort Baud Rate Tab

Overview The TruePort utility acts as a COM port redirector that allows applications to talk to serial devices across a network as though the serial devices were directly attached to the server. For IOLAN I/O models, you can also monitor and control I/O through the TruePort client.

Functionality Since some older applications may not support the higher baud rates that the IOLAN is capable of achieving, the baud rate can be mapped to a different value on the IOLAN. Through TruePort, you can map the baud rate of the host COM port to a higher baud rate for the serial line that connects the serial device and the IOLAN. See TruePort on page 207 for more information about the TruePort utility.

Field Definitions

Perle Systems TS2 — Field Definitions diagram (page 115)
Fig. 83 · Field Definitions

Configure the following parameter:

Actual Baud Rate The actual baud rate that runs between the IOLAN and the connected serial device. Range: 50-230400, you can also specify a custom baud rate

Advanced

Page 116 of the Perle Systems TS2 user manual — TruePort Baud Rate Tab
Page 116 · click to enlarge
Page 116

Advanced

Page 117 of the Perle Systems TS2 user manual — Configuring Users Chapter 8 8
Page 117 · click to enlarge
Page 117

Configuring Users Chapter 8 8

Introduction

You can configure up to four users in the IOLAN’s local user database, in addition to the Admin user. A user can even represent a device, like a barcode reader or a card swipe device, that you want to be authenticated.

Perle Systems TS2 — Configuring Users Chapter 8 8 diagram (page 117)
Fig. 84 · Configuring Users Chapter 8 8

When users are connecting to the IOLAN via serial ports, the user database can be used to:

z Have the user authenticated prior to establishing a connection to a network host.

z Establish a different connection type to the host specific to each user.

z Create a profile different from the Default user profile.

When users are connecting to the IOLAN from a network connection, the user database can be used to:

z Authenticate users prior to providing access to a serially attached console port (such as a Unix server or router).

Page 118 of the Perle Systems TS2 user manual — Functionality
Page 118 · click to enlarge
Page 118

User Settings

Overview

The Users window allows you to add, edit, and delete users from the IOLAN.

Functionality

The Users window displays the users who have been configured. You can add users, edit existing users, or delete users from this window. See Adding/Editing Users on page 119 for information on the parameters available when adding or editing a user.

Perle Systems TS2 — Functionality diagram (page 118)
Fig. 85 · Functionality

User Settings

Page 119 of the Perle Systems TS2 user manual — Field Descriptions
Page 119 · click to enlarge
Page 119

Adding/Editing Users

General Tab

Overview The General tab configures the basic user information.

Functionality You must, minimally, provide a User Name and Level for a user.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 119)
Fig. 86 · Field Descriptions

Configure the following parameters:

User Name The name of the user. Restrictions: Do not use spaces.

Password The password the user will need to enter to login to the IOLAN.

Confirm Password Enter the user’s password again to verify it is entered correctly.

Adding/Editing Users

Page 120 of the Perle Systems TS2 user manual — Adding/Editing Users
Page 120 · click to enlarge
Page 120

Level The access that a user is allowed. Data Options:

z Admin—The admin level user has total access to the IOLAN. You can create more than one admin user account but we recommend that you only have one. They can monitor and configure the IOLAN. Users configured with this level can access the unit either via serial Terminal Profile connection or via a network originated Telnet connection to the IOLAN.

z Normal—The Normal level user has limited access to the IOLAN. Limited CLI commands and Menu access are available with the ability to configure the user’s own configuration settings. Users configured with this level can access the unit either via serial Terminal Profile connection or via a network originated Telnet connection to the IOLAN.

z Restricted—The Restricted level user can only access predefined sessions or access the Easy Port Access menu. Users configured with this level will be restricted to pre-defined sessions or limited CLI commands when connecting through the serial port via the Terminal Profile. The CLI commands are limited to those used for initiating a session. If connection to the IOLAN is done with Telnet from the network, the user will be presented with the Easy Port Access menu.

z Menu—The menu level user will only be able to access predefined session when connecting through a serial port with the Terminal profile or will be limited to the Easy Port Access menu when connecting from the network. The Easy Port Access allows the user to connect to the accessible line without disconnecting their initial connection to the IOLAN. Does not have any access to CLI commands. When the Admin user logs into the IOLAN, the prompt ends with a #, whereas all other users’ prompts ends with a $ or £, depending on the character set. Default: Normal

Note: A technique for giving a serially attach user (dial-in or terminal attached), the same menus as one that is network connected is to do the following: 1. Define the serial port with a Terminal Profile using telnet protocol with a direct connection to Host IP address 127.0.0.0 (local loop back). 2. When the user connects to that serial port a Telnet session will be established to the IOLAN and the user will appear to have connected from the network.

Adding/Editing Users

Page 121 of the Perle Systems TS2 user manual — Field Descriptions
Page 121 · click to enlarge
Page 121

Services Tab

Overview The Services tab configures the connection parameters for a user. Any connection parameters configured in this window will override the serial port connection parameters.

Functionality When a Terminal profile is set for the serial port and Require Login has been selected, user’s accessing the IOLAN through the serial port will be authenticated. Once authentication is successful, the IOLAN will start a Telnet connection to the specified Host IP/TCP Port.

Within the Terminal profile, there are a number of settings that apply to possible Services. Once it is known which user is connected, and which service is to be used, then the settings from both the Terminal profile and the user are used. User parameters take precedence over serial port parameters.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 121)
Fig. 87 · Field Descriptions

Configure the following parameters:

Service Used in conjunction with the Terminal Profile. After the user has successfully been authenticated, the specified service is started. Data Options: DSPrompt, Telnet, TCP Clear Default: DSPrompt

Host IP When the User Service is set to Telnet or TCP Clear, the target host IP address. If no IP address is specified, the Host IP value in the Default User configuration will be used. Default: 0.0.0.0.

TCP Port When the User Service is Telnet, this is the target port number. The default value will change based on the type of Service selected; the most common known port numbers are used as the default values.

Adding/Editing Users

Page 122 of the Perle Systems TS2 user manual — Field Descriptions
Page 122 · click to enlarge
Page 122

Advanced Tab

Overview The Advanced tab is used to configure those parameters that control the user session; this includes session length, language, the hotkey used for switching between sessions.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 122)
Fig. 88 · Field Descriptions

Configure the following parameters:

Idle Timeout The amount of time, in seconds, before the IOLAN closes a connection due to inactivity. The default value is 0 (zero), meaning that the Idle Timer will not expire (the connection is open permanently). The User Idle Timeout will override all other Serial Port Idle Timeout parameters. Range: 0-4294967 Default: 0

Session Timeout The amount of time, in seconds, before the IOLAN forcibly closes a user’s session (connection). The default value is 0 (zero), meaning that the session timer will not expire (the session is open permanently, or until the user logs out). The User Session Timeout will override all other Serial Port Session Timeout parameters. Range: 0-4294967 Default: 0

Language You can specify whether a user will use English or Custom Language as the language that appears in the Menu, CLI, or WebManager. The IOLAN supports one custom language that must be downloaded to the IOLAN. Default: English

See Language Support on page 179 for more information about Custom Languages.

Adding/Editing Users

Page 123 of the Perle Systems TS2 user manual — Sessions Tab
Page 123 · click to enlarge
Page 123

Hotkey Prefix The prefix that a user types to control the current session. Data Options:

z ^a number—To switch from one session to another, press ^a (Ctrl-a) and then the required session number. For example, ^a 2 would switch you to session 2. Pressing ^a 0 will return you to the IOLAN Menu.

z ^a n—Display the next session. The current session will remain active. The lowest numbered active session will be displayed.

z ^a p—Display the previous session. The current session will remain active. The highest numbered active session will be displayed.

z ^a m—To exit a session and return to the IOLAN. You will be returned to the menu. The session will be left running.

z ^a l—(Lowercase L) Locks the serial port until the user unlocks it. The user is prompted for a password (any password, excluding spaces) and the serial port is locked. The user must retype the password to unlock the serial port.

z ^r—When you switch from a session back to the Menu, the screen may not be redrawn correctly. If this happens, use this command to redraw it properly. This is always Ctrl R, regardless of the Hotkey Prefix. The User Hotkey Prefix value overrides the Serial Port Hotkey Prefix value. You can use the Hotkey Prefix keys to lock a serial port only when the serial port’s Allow Port Locking parameter is enabled. Default: Hex 01 (Ctrl-a or ^a)

Sessions Tab

Overview The Sessions tab is used to configure specific connections for users who are accessing the network through the IOLAN’s serial port.

Functionality Users who have successfully logged into the IOLAN (User Service set to DSprompt) can start up to four login sessions on network hosts. These users start sessions through the Easy Port Menu option Sessions.

Multiple sessions can be run simultaneously to the same host or to different hosts. Users can switch between different sessions and also between sessions and the IOLAN using Hotkey commands (see Hotkey Prefix on page 123 for a list of commands).

Users with Admin or Normal privileges can define new sessions and use them to connect to Network hosts; they can even configure them to start automatically on login to the IOLAN. Restricted and Menu users can only start sessions predefined for them in their user configuration.

Adding/Editing Users

Page 124 of the Perle Systems TS2 user manual — Field Descriptions
Page 124 · click to enlarge
Page 124

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 124)
Fig. 89 · Field Descriptions

Configure the following parameters:

Session 1, 2, 3, 4 You can configure up to four (4) sessions that the user can select from to connect to a specific host after that user has successfully logged into the IOLAN (used only on serial ports configured for the Terminal profile).

Data Options:

z None—No connection is configured for this session.

z Telnet—For information on the Telnet connection window, see Telnet Settings on page 95. Default: None

Settings Button Click this button to configure the connection parameters for this session.

Specify whether or not the session(s) will start automatically when the user logs into the IOLAN. Default: Disabled

Host The host that the user will connect to in this predefined session. Default: None

TCP Port The TCP port that the IOLAN will use to connect to the host in this predefined session. Default: 23

Adding/Editing Users · Connect Automatically

Page 125 of the Perle Systems TS2 user manual — Field Descriptions
Page 125 · click to enlarge
Page 125

Serial Port Access Tab

Overview The Serial Port Access tab controls the user’s read/write access on any given IOLAN serial port. This pertains to users that are connecting from the network to a serial over a Console Management type session.

This can be useful when you have multiple users connecting to the same serial device and you wish to control the viewing and/or the write to and from the device. See the Multisessions and User Authentication parameters in the Console Management Profile on page 74 for the serial port settings.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 125)
Fig. 90 · Field Descriptions

Configure the following parameters:

Serial Port Access Specifies the user access rights to each IOLAN serial port device. There can be multiple users connected to a particular serial device and these settings determine the rights of this user for any of the listed serial ports. Data Options:

z Read/Write—The user has read and write access to the serial port.

z Read In—The User will see data going to the serial port, from all network-connected users that have write privileges to this serial port.

z Read Out—The user will have access to all data originating from the serial device. Users can read data going in both directions by selecting both the Read In and Read Out options. Default: Read/Write

Adding/Editing Users

Page 126 of the Perle Systems TS2 user manual — Serial Port Access Tab
Page 126 · click to enlarge
Page 126

Adding/Editing Users

Page 127 of the Perle Systems TS2 user manual — Functionality
Page 127 · click to enlarge
Page 127

Configuring Security Chapter 9 9

Introduction

The Security group includes the following configuration options:

Perle Systems TS2 — Configuring Security Chapter 9 9 diagram (page 127)
Fig. 91 · Configuring Security Chapter 9 9

z Services—This configuration window is used to enable/disabled client and daemon services that run in the IOLAN. See Services on page 127 for more information.

Services

Overview

Services are either daemon or client processes that run on the IOLAN. You can disable any of the services for security reasons.

Functionality

If you disable any of the daemons, it can affect how the IOLAN can be used or accessed. For example, if you disable the WebManager service, you will not be able to access the IOLAN with the WebManager. If you disable the DeviceManager service, the DeviceManager will not be able to connect to the IOLAN. If you do not want to allow users to Telnet to the IOLAN, you can disable the Telnet Server service; therefore, disabling daemons can also be used as an added security method for accessing the IOLAN.

By default, all daemon and client applications are enabled and running on the IOLAN.

Page 128 of the Perle Systems TS2 user manual — Field Descriptions
Page 128 · click to enlarge
Page 128

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 128)
Fig. 92 · Field Descriptions

Enable/disable the following options:

Telnet Server Telnet daemon process in the IOLAN listening on TCP port 23.

The TruePort daemon process in the IOLAN that supports TruePort Full Mode on UDP port 668. You can still communicate with the IOLAN in Light Mode when this service is disabled.

Syslog Client Syslog client process in the IOLAN.

Modbus Modbus daemon process in the IOLAN listening on port 502.

SNMP SNMP daemon process in the IOLAN listening on port 161.

DeviceManager DeviceManager daemon process in the IOLAN. If you disable this service, you will not be able to connect to the IOLAN with the DeviceManager application. The DeviceManager listens on port 33812 and sends on port 33813.

WebManager daemon process in the IOLAN listening on port 80.

Services · TruePort Full Mode · WebManager (HTTP)

Page 129 of the Perle Systems TS2 user manual — Configuring I/O Interfaces Chapter 10 10
Page 129 · click to enlarge
Page 129

Configuring I/O Interfaces Chapter 10 10

Introduction

There is a line of I/O IOLANs that can control/monitor the following types of I/O:

Perle Systems TS2 — Configuring I/O Interfaces Chapter 10 10 diagram (page 129)
Fig. 93 · Configuring I/O Interfaces Chapter 10 10

Some of the models are I/O combinations and some of the models support one I/O type.

Show 4 more labels / short text on this page
z Analog Input · z Digital Input/Output · z Relay Output · z Temperature Input
Page 130 of the Perle Systems TS2 user manual — Field Descriptions
Page 130 · click to enlarge
Page 130

Settings

Overview

The I/O Interfaces Settings window configures the parameters that are global to all I/O channels.

I/O Access Functionality

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 130)
Fig. 94 · Field Descriptions

Configure the following parameters:

Enable I/O Access to Modbus protocol

Enables/disables Modbus as the communication protocol for all the I/O channels. Default: Disabled

UID This is the UID you are assigning to the IOLAN, which is acting as a Modbus slave. Default: 255

Advanced Modbus Settings Button

Click this button to configure global Modbus Slave settings.

See Advanced Slave Modbus Settings on page 131 for field descriptions.

Allow Modbus TCP Application (API)

Allows a host running a Modbus/TCP application to communicate to the I/O channels using the standard Modbus API. Default: Permanently enabled when Enable I/O Access via Modbus protocol is enabled

See Modbus I/O Access on page 153 for function codes and I/O coil/registration descriptions.

Allow Modbus RTU/ASCII via TruePort

Enables/disables serial Modbus application access to the I/O over the network using the TruePort COM redirector feature. Default: Disabled

See Modbus I/O Access on page 153 for function codes and I/O coil/registration descriptions and Accessing I/O Data Via TruePort on page 160 for the Perle API.

Settings

Page 131 of the Perle Systems TS2 user manual — Settings
Page 131 · click to enlarge
Page 131

Enable I/O Access via TruePort

Enables/disables serial application access to the I/O over the network using the TruePort COM redirector feature. Default: Disabled

Listen TCP Port The TCP port that the IOLAN will listen to for I/O channel data requests from TruePort. Default: 33816

Allow I/O Access via API through TruePort

Allows serial application access to the I/O over the network using the TruePort COM redirector feature via a custom application using the Perle API. Default: Permanently enabled when Enable I/O Access via TruePort is enabled

See Modbus I/O Access on page 153 for function codes and I/O coil/registration descriptions and Accessing I/O Data Via TruePort on page 160 for the Perle API.

Advanced Slave Modbus Settings The parameters in this window configure global Modbus gateway settings that apply to all serial ports configured first as the Modbus Gateway profile and then as a Modbus Slave.

Perle Systems TS2 — Settings diagram (page 131)
Fig. 95 · Settings

Configure the following parameters:

TCP/UDP Port The network port number that the Slave Gateway will listen on for both TCP and UDP messages. Default: 502

Next Request Delay A delay, in milliseconds, to allow serial slave(s) to re-enable receivers before

issuing next Modbus Master request. Range: 0-1000 Default: 50 ms

Enable Serial Modbus Broadcasts

When enabled, a UID of 0 (zero) indicates that the message will be broadcast to all Modbus Slaves. Default: Disabled

Request Queuing When enabled, allows multiple, simultaneous messages to be queued and processed in order of reception. Default: Enabled

Settings

Page 132 of the Perle Systems TS2 user manual — Field Descriptions
Page 132 · click to enlarge
Page 132

Embedded When this option is selected, the address of the slave Modbus device is embedded in the message header. Default: Enabled

Remapped Used for single device/port operation. Older Modbus devices may not include a UID in their transmission header. When this option is selected, you can specify the UID that will be inserted into the message header for the Modbus slave device. This feature supersedes the Broadcast feature. Default: Disabled

Remap UID Specify the UID that will be inserted into the message header for the Slave Modbus serial device. Range: 1-247 Default: 1

Failsafe Timer Functionality

Overview The Failsafe Timer tab configures the I/O failsafe timer. The Failsafe Timer is enabled on a global basis and provides a trigger mechanism that can be configured for each channel when no I/O traffic/management has occurred for the specified amount of time. A Failsafe Action can be configured for each Digital Output channel, each Serial Signal Output channel (DTR and RTS), and each Relay channel to either Activate or Deactivate the output.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 132)
Fig. 96 · Field Descriptions

Configure the following parameters:

Enable I/O Failsafe Timer

Enables/disables the Failsafe Timer. This is the global setting that must be enabled to set the Failsafe Action on the channel for digital outputs and relays. When this timer expires because of no I/O activity within the specified time interval, the Failsafe Action set for the channel determines the action on the output. Default: Disabled

Timeout The number of seconds that must elapse with no I/O activity before the channel Failsafe Action is triggered. Range: 1-9999 Default: 30 seconds

Settings

Page 133 of the Perle Systems TS2 user manual — Field Descriptions
Page 133 · click to enlarge
Page 133

UDP Functionality

Overview The UDP tab configures the I/O UDP broadcast settings. The I/O UDP broadcast feature periodically broadcasts the I/O channel status in a UDP message.

You can configure up to four sets of IP address entries (each entry consisting of a start and end IP address range) to broadcast I/O status data. The data depends on the I/O model (Analog, Digital, Serial Signals) and contains information for all channels.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 133)
Fig. 97 · Field Descriptions

Configure the following parameters:

Enable UDP Broadcast of I/O Status

Enables/disables UDP broadcast of I/O channel status (data). Default: Disabled

Broadcast Interval Enter the interval, in seconds, for UDP broadcasts of I/O channel status (data).

Range1-9999 Default: 30 seconds

Settings Button Click this button to configure the UDP IP addresses that will receive the I/O status information.

See I/O UDP Settings on page 134 for field descriptions for the I/O UDP Settings window.

Settings

Page 134 of the Perle Systems TS2 user manual — Field Descriptions
Page 134 · click to enlarge
Page 134

I/O UDP Settings

Perle Systems TS2 — I/O UDP Settings diagram (page 134)
Fig. 98 · I/O UDP Settings

Configure the following parameters:

UDP Entry When enabled, broadcasts I/O status (data) to the specified range of IP addresses. Default: Disabled

Start IP Address The first host IP address in the range of IP addresses (for IPV4 or IPV6) that the IOLAN will listen for messages from and/or send messages to.

End IP Address The last host IP address in the range of IP addresses (for IPV4, not required for IPV6) that the IOLAN will listen for messages from and/or send messages to.

Port The UDP port that the IOLAN will use to relay messages to servers/hosts. Default: 0 (zero)

Temperature Functionality

Overview The Temperature tab configures the temperature scale settings for T4 models.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 134)
Fig. 99 · Field Descriptions

Configure the following parameter:

Temperature Scale Select the temperature scale that will be used to display temperature data.

Data OptionsFahrenheit or Celsius Default: Celsius

Settings

Page 135 of the Perle Systems TS2 user manual — A4D2
Page 135 · click to enlarge
Page 135

Channels

The Channels section displays the I/O Channels window, through which you can enable/disable the I/O channels.

Perle Systems TS2 — Channels diagram (page 135)
Fig. 100 · Channels

Highlight a channel and then click the Edit button to configure the parameters for that channel.

Analog

Overview Analog channels monitor current/voltage input. Note that the internal jumpers must match the software setting (by default, they are set to Current); see Analog Input Module on page 199 to find out how to set the internal jumpers.

For example, in an industrial freezer warehouse, the IOLAN A4R2 is used to monitor humidity transducers, which are in place to help prevent freezer burn. If the humidity reaches a certain percentage (monitored by an Analog channel) a syslog message is sent to the Monitoring Application. The Monitoring Application then sends a command to the IOLAN via the Perle API that causes the Relay channel to activate an internal freezer dehumidifier. The relay is turned off when the Analog channel sends a clear syslog message to the Monitoring Application and the Relay channel is deactivated.

A4D2

Show 11 more labels / short text on this page
Channels · Relay · Network · perle · Analog I/O · Analog · Device Server · Relay · Monitoring Application · Industrial Freezers · Analog
Page 136 of the Perle Systems TS2 user manual — Field Descriptions
Page 136 · click to enlarge
Page 136

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 136)
Fig. 101 · Field Descriptions

Configure the following parameters:

Description Provide a description of the channel, making it easier to identify. Data Options: Maximum 20 characters, including spaces

Type Select the type of input being measured. Data Options: Current or Voltage Default: Current

Range Select the range for the measurement type. Data Options:

z Current—0-20 mA, 4-20 mA

z Voltage—+/- 10V, +/- 5V, +/- 1V, +/- 500mV, +/- 150mV Default: Current is 0-20 mA. Voltage is +/- 10V.

Click the Alarm Settings button to specify the trigger and clear levels for the alarms. Notice that the Analog Alarm Settings window has two alarm configuration views, a basic alarm view and an advanced alarm view.

See Alarm Settings on page 148 for field descriptions.

Channels · Alarm Settings Button

Page 137 of the Perle Systems TS2 user manual — Digital Input
Page 137 · click to enlarge
Page 137

Digital Input

Overview When the channel is set for digital input, it monitors voltage or current. Note that the internal jumpers must match the software setting and must be set to Input, which is the default; see Digital I/O Module on page 198 to find out how to set the internal jumpers.

Functionality The Digital input channels allow you to configure the following options:

z You can choose to remember the last state change, or latch, that occurred. Your options are to latch (remember) when the state changes from inactive to active or active to inactive.

z You can choose to invert the signal, which is useful if your sensor is wired in such a way that closed is actually inactive, whereas closed is normally considered active.

z You can also configure an alarm trigger and clear mode based on whether the Digital input is active or inactive, sending a syslog message and/or SNMP trap when the alarm is triggered or cleared.

In an industrial freezer warehouse example, a D4 is used to monitor the open door sensor, so that every time a freezer door is opened, an alarm is triggered and a syslog message is sent to syslog, where the monitoring application notes the time.

Show 9 more labels / short text on this page
Channels · Input D4 · Network · perle · Digital I/O · Monitoring Application · Device Server · Input · Industrial Freezers
Page 138 of the Perle Systems TS2 user manual — Field Descriptions
Page 138 · click to enlarge
Page 138

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 138)
Fig. 102 · Field Descriptions

Configure the following parameters:

Description Provide a description of the channel, making it easier to identify. Data Options: Maximum 20 characters, including spaces

Input Mode When selected, the channel will be reading the status of the line (input). The internal jumpers must match the software configuration; the internal jumpers are factory configured for Input Mode. Default: Input Mode

Latch Latches (remembers) the activity transition (active to inactive or inactive to active). Data Options: None, Inactive-to-Active, Active-to-Inactive Default: None

Invert Signal When enabled, inverts the actual condition of the I/O signal in the status; therefore, an inactive status will be displayed as active. Default: Disabled

Trigger When the trigger condition is met, triggers the specified alarm action. Data Options:

z Disabled—No alarm settings. This is the default.

z Inactive—When the expected Digital input is active, going inactive will trigger an alarm.

z Active—When the expected Digital input is inactive, going active will trigger an alarm. Default: Disabled

Channels

Page 139 of the Perle Systems TS2 user manual — Digital Input
Page 139 · click to enlarge
Page 139

Auto Clear Mode When enabled, automatically clears the alarm when the trigger condition changes; for example, if the Trigger is Inactive and the alarm is triggered, once the input becomes active again, the alarm will automatically be cleared Default: Enabled

When enabled, a triggered alarm must be manually cleared. Default: Disabled

Syslog When enabled, sends a message to syslog when an alarm is triggered or cleared. The syslog entry includes the severity level and the value that caused the alarm to trigger or clear. The syslog message is associated with Level Critical. Default: Disabled

SNMP When enabled, sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the severity level and whether the alarm was triggered or cleared. Default: Disabled

Channels · Manual Clear Mode

Page 140 of the Perle Systems TS2 user manual — D4
Page 140 · click to enlarge
Page 140

Digital Output

Overview When the channel is set for digital output, either voltage is applied to the channel or the channel is grounded. Note that the internal jumpers must match the software setting and must be set to Output (by default, they are set to Input); see Digital I/O Module on page 198 to find out how to set the internal jumpers.

Functionality The Digital output channels support three types of Digital output: sink (voltage), source (ground), and sink and source (apply voltage or ground). For the output type, you can configure the following options:

z You can choose to manually activate/deactivate the Digital output.

z You can choose to manually activate/deactivate the Digital output and then specify that the Digital output will either pulse (you get to specify the active and inactive pulse times) continuously or for a specified number of pulse counts.

z You can choose to manually activate/deactivate the Digital output and then specify a delay before the output goes from inactive to active or active to inactive.

z You can also specify a failsafe action that can either activate or inactivate the Digital output when the failsafe timer is triggered (see Failsafe Timer Functionality on page 132 for more information).

In an industrial freezer warehouse, the IOLAN D4 is used to monitor the freezer doors. When one of the industrial freezer doors are left open for more than five minutes, the Monitoring Application (using the Perle API) starts the Digital output sink, causing the strobe light on top of the offending freezer to activate.

D4

Show 11 more labels / short text on this page
Channels · Output · Input · Network · perle · Digital I/O · Output · Monitoring Application · Device Server · Input · Industrial Freezers
Page 141 of the Perle Systems TS2 user manual — Field Descriptions
Page 141 · click to enlarge
Page 141

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 141)
Fig. 103 · Field Descriptions

Configure the following parameters:

Description Provide a description of the channel, making it easier to identify. Data Options: Maximum 20 characters, including spaces

Output Mode When selected, the channel will drive the line (output). The internal jumpers must match the software configuration, so if you change this setting to Output Mode, you will have to also change the internal hardware jumpers. Default: Disabled

Type Specify the type of digital output. Data Options:

z Sink—Specifies that the channel will be grounded when active.

z Source—Specifies that the channel will provide voltage when active.

z Sink and Source—Specifies that channel will be grounded when it is inactive and will provide voltage when it is active. Default: Sink

Output Specify how the channel output will be handled. Data Options:

z Manual—You must manually manipulate the channel output.

z Pulse—Activates and deactivates the channel output activity in intervals after it is manually activated.

z Inactive-to-Active Delay—The channel output will remain inactive for the specified time interval after it is manually started.

z Active-to-Inactive Delay—The channel output will go inactive after the specified time interval after it is manually started. Default: Manual

Channels

Page 142 of the Perle Systems TS2 user manual — Digital Output
Page 142 · click to enlarge
Page 142

Pulse Mode When Output is set to Pulse, you can specify the manner of the pulse. Data Options:

z Continuous—Continuously pulses active and inactive.

z Count—Pulses an active/inactive sequence for the specified number of times. Default: Continuous

Pulse Count The channel output will pulse for the specified number of times; each count consists of an active/inactive sequence. Default: 1

How long the channel will remain inactive during pulse mode. Range: 1-9999 x 100 ms Default: 1 (100 ms)

How long the channel will be active during the pulse mode. Range: 1-9999 x 100 ms Default: 1 (100 ms)

Delay How long to delay an active-to-inactive or inactive-to-active setting after it is manually started. Range: 1-9999 x 100 ms Default: 1 (100 ms)

Failsafe Action When there has been no I/O activity within the specified time (set in the I/O Interfaces, Settings on the Failsafe Timer tab) and the Failsafe Timer is triggered. Data Options:

z None—The state of the Digital/Relay output remains the same, no change.

z Activate Output—Activates the channel.

z Deactivate Output—Deactivates the channel. Default: None

Channels · Inactive Signal Width · Active Signal Width

Page 143 of the Perle Systems TS2 user manual — A4D2
Page 143 · click to enlarge
Page 143

Relay

Overview Relay channels can open or close a contact for a higher voltage circuit using a lower level control voltage. The Relay output channels work as a physical on/off switch, and are used to drive higher voltage devices with a lower controlling voltage.

You can configure the following Relay output channel options:

z You can choose to manually activate/deactivate the Relay output.

z You can choose to manually activate/deactivate the Relay output and then specify that the Relay output will either pulse (you get to specify the active and inactive pulse times) continuously or for a specified number of pulse counts.

z You can choose to manually activate/deactivate the Relay output and then specify a delay before the output goes from inactive to active or active to inactive.

z You can also specify a failsafe action that can either active or inactivate the Relay output when the failsafe timer is triggered (see Failsafe Timer Functionality on page 132 for more information).

In an industrial freezer warehouse, the IOLAN A4R2 is used to monitor humidity transducers, which are used to help prevent freezer burn. If the humidity reaches a certain percentage (monitored by an Analog channel) a syslog message is sent to the Monitoring Application, causing the Relay channel to activate an internal freezer dehumidifier. The Relay channel is deactivated when the Analog channel sends a clear syslog message to the Monitoring Application and the Relay channel is deactivated.

A4D2

Show 11 more labels / short text on this page
Channels · Relay · Network · perle · Relay I/O · Analog · Device Server · Relay · Monitoring Application · Industrial Freezers · Analog
Page 144 of the Perle Systems TS2 user manual — Field Descriptions
Page 144 · click to enlarge
Page 144

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 144)
Fig. 104 · Field Descriptions

Configure the following parameters:

Description Provide a description of the channel, making it easier to identify. Data Options: Maximum 20 characters, including spaces

Output Specify how the channel output will be handled. Data Options:

z Manual—You must manually manipulate the channel output.

z Pulse—Activates and deactivates the channel output activity in intervals after it is manually activated.

z Inactive-to-Active Delay—The channel output will remain inactive for the specified time interval after it is manually started.

z Active-to-Inactive Delay—The channel output will go inactive after the specified time interval after it is manually started. Default: Manual

Pulse Mode When Output is set to Pulse, you can specify the manner of the pulse. Data Options:

z Continuous—Continuously pulses active and inactive.

z Count—Pulses an active/inactive sequence for the specified number of times. Default: Continuous

Pulse Count The channel output will pulse for the specified number of times; each count consists of an active/inactive sequence. Default: 1

How long the channel will remain inactive during pulse mode. Range: 1-9999 x 100 ms Default: 1 (100 ms)

Channels · Inactive Signal Width

Page 145 of the Perle Systems TS2 user manual — Relay
Page 145 · click to enlarge
Page 145

How long the channel will be active during the pulse mode. Range: 1-9999 x 100 ms Default: 1 (100 ms)

Delay How long to delay an active-to-inactive or inactive-to-active setting after it is manually started. Range: 1-9999 x 100 ms Default: 1 (100 ms)

Failsafe Action When there has been no I/O activity within the specified time (set in the I/O Interfaces, Settings on the Failsafe Timer tab) and the Failsafe Timer is triggered. Data Options:

z None—The state of the Digital/Relay output remains the same, no change.

z Activate Output—Activates the channel.

z Deactivate Output—Deactivates the channel. Default: None

Channels · Active Signal Width

Page 146 of the Perle Systems TS2 user manual — T4
Page 146 · click to enlarge
Page 146

Temperature

Temperature input channels monitor RTD or thermocouple temperature sensors inputs for the most common ranges. You can also configure severity alarms that can send a syslog message and/or an SNMP trap when an alarm is triggered or cleared; See Alarm Settings on page 148 for more information about the alarms.

RTD ranges are:

z Pt100 a=385 -50 to 150C z Pt100 a=392 -50 to 150C z Pt1000 a=385 -40 to 160C

z Pt100 a=385 0 to 100C z Pt100 a=392 0 to 100C z NiFe604 a=518 -80 to 100C

z Pt100 a=385 0 to 200C z Pt100 a=392 0 to 200C z NiFe604 a=518 0 to 100C

z Pt100 a=385 0 to 400C z Pt100 a=392 0 to 400C

z Pt100 a=385 -200 to 200C z Pt100 a=392 -200 to 200C

Thermocouple ranges are:

z B 500 to 1800C z K 0 to 1370C z T -100 to 400C

z E 0 to 1000C z R 500 to 1750C

z J 0 to 760C z S 500 to 1750C

The the following example, a Temperature I/O IOLAN is used to monitor industrial freezer as a temperature sensor, with an alarm set to send a syslog message if the temperature rises above 31o C.

T4

Show 7 more labels / short text on this page
Channels · Network · perle · Temperature I/O · Monitoring Application · Device Server · Industrial Freezers
Page 147 of the Perle Systems TS2 user manual — Field Descriptions
Page 147 · click to enlarge
Page 147

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 147)
Fig. 105 · Field Descriptions

Configure the following parameters:

Description Provide a description of the channel, making it easier to identify. Data Options: Maximum 20 characters, including spaces

Type Specify the type of sensor you are using to measure temperature. Data Options: RTD, Thermocouple Default: RTD

Range Specify the temperature range that you want to measure. Data Options:

z RTD—Pt100 a=385 -50 to 150C, Pt100 a=385 0 to 100C, Pt100 a=385 0 to 200C, Pt100 a=385 0 to 400C, Pt100 a=385 -200 to 200C, Pt100 a=392 -50 to 150C, Pt100 a=392 0 to 100C, Pt100 a=392 0 to 200C, Pt100 a=392 0 to 400C, Pt100 a=392 -200 to 200C, Pt1000 a=385 -40 to 160C, NiFe604 a=518 -80 to 100C, NiFe604 a=518 0 to 100C

z Thermocouple—B 500 to 1800C, E 0 to 1000C, J 0 to 760C, K 0 to 1370C, R 500 to 1750C, S 500 to 1750C, T -100 to 400C Default: RTD is Pt100 a=385 -50 to 150C. Thermocouple is J 0 to 760C.

s Click the Alarm Settings button to specify the trigger and clear levels for the alarms. Notice that the Analog Alarm Settings window has two alarm configuration views, a basic alarm view and an advanced alarm view.

See Alarm Settings on page 148 for field descriptions.

Channels · Alarm Settings Button

Page 148 of the Perle Systems TS2 user manual — Alarm Settings
Page 148 · click to enlarge
Page 148

Alarm Settings

Analog and Temperature input models support an Alarm mechanism in which you can specify up to five severity levels of alarm triggers and clear levels; the alarm triggers/clear levels can activate in either increasing or decreasing severity levels.

Each time an alarm is triggered or cleared, you can specify any combination of the following to be initiated:

z An SNMP trap

z A message to syslog

Basic Analog Alarm Settings The basic Analog Alarm Settings window allows you to configure one severity alarm, whereas the advanced window allows you to configure up to five severity alarm levels.

Perle Systems TS2 — Alarm Settings diagram (page 148)
Fig. 106 · Alarm Settings

Configure the following parameters:

Trigger alarm when input value is

Specify the value that will trigger an alarm, the measurement is based on the Type and Range that you specify. This value must not fall within the scope of the value used to clear an alarm.

Clear alarm when input value is

Specify that value that will clear an alarm, the measurement is based on the Type and Range that you specify. This value must not fall within the scope of the value used to trigger an alarm.

Send Syslog Alert When enabled, sends a message to syslog when an alarm is triggered or cleared. The syslog entry includes the severity level and the value that caused the alarm to trigger or clear. The syslog message is associated with Level Critical. Default: Disabled

Send SNMP Alert When enabled, sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the severity level and whether the alarm was triggered or cleared. Default: Disabled

Channels

Page 149 of the Perle Systems TS2 user manual — Alarm Settings
Page 149 · click to enlarge
Page 149

Advanced Analog Alarm Settings The advanced Analog Alarm Settings window expands the basic alarm settings options to up to five severity levels.

Perle Systems TS2 — Alarm Settings diagram (page 149)
Fig. 107 · Alarm Settings

Configure the following parameters:

Trigger Type If the Trigger Type is Low, an alarm is triggered when the input drops below the specified Trigger value; other severity level trigger values must decrease in value with each subsequent level. If the Trigger Type is High, an alarm is triggered when the input is higher than the specified Trigger value; other severity level trigger values must increase in value with each subsequent level.

Clear Mode To clear an alarm, the input must drop below the specified value when Trigger Type is High or go above the specified value when Trigger Type is Low.

Level 1-5 Defines the Level severity settings for up to five levels. If the Trigger Type is Low, an alarm is triggered when the input drops below the specified Trigger value; other severity level trigger values must decrease in value with each subsequent level. If the Trigger Type is High, an alarm is triggered when the input is higher than the specified Trigger value; other severity level trigger values must increase in value with each subsequent level.

Trigger If the Trigger Type is Low, an alarm is triggered when the input drops below the specified Trigger value; other severity level trigger values must decrease in value with each subsequent level. If the Trigger Type is High, an alarm is triggered when the input is higher than the specified Trigger value; other severity level trigger values must increase in value with each subsequent level.

Clear To clear an alarm, the input must drop below the specified value when Trigger Type is High or go above the specified value when Trigger Type is Low.

Syslog When enabled, sends a message to syslog when an alarm is triggered or cleared. The syslog entry includes the severity level and the value that caused the alarm to trigger or clear. The syslog message is associated with Level Critical. Default: Disabled

Channels

Page 150 of the Perle Systems TS2 user manual — UDP Unicast Format
Page 150 · click to enlarge
Page 150

I/O UDP

SNMP When enabled, sends an SNMP trap when an alarm is triggered or cleared. The trap consists of the severity level and whether the alarm was triggered or cleared. Default: Disabled

I/O UDP

The I/O UDP broadcast feature periodically broadcasts the I/O channel status in a UDP message.

You can configure up to four sets of IP address entries (each entry consisting of a start and end IP address range) to broadcast I/O status data. The data depends on the I/O model (Analog, Digital, Serial Pin Signals) and contains information for all channels.

UDP Unicast Format

In order to interpret the UDP unicast data, you must use the following tables to decipher the appropriate data. If your model does not support a data format (for example, digital data) or you do not have any channels configured for a data format, it will be included in UDP broadcast package, with a Total Length of 0 (zero) and no data following.

Version Total Length Analog Data Digital Data Serial Signal Data

Each section, with the exceptions of the Version and Total Length sections, is comprised of its own subset of bytes.

Analog Data Each Analog channel is comprised of the following data fields (big Endian format):

2 Bytes 1 Byte (in bits)

The following section describes the values in the Analog Data field:

z curRawValue—The current raw value received from the Analog to Digital converter.

z minRawValue—The minimum value received from the Analog to Digital converter until it is cleared.

z maxRawValue—The maximum value received from the Analog to Digital converter until it is cleared.

z curEngValue—The current converted value (voltage/current for Analog or Celsius/Fahrenheit for Temperature).

z minEngValue—The minimum converted value (voltage/current for Analog or Celsius/Fahrenheit for Temperature) until it is cleared.

z maxEngValue—The maximum converted value (voltage/current for Analog or Celsius/Fahrenheit for Temperature) until it is cleared.

Show 10 more labels / short text on this page
Total Length · *Data Exists · Data · curRawValue · 2 Bytes minRawValue · 2 Bytes maxRawValue · 2 Bytes curEngValue · 4 Bytes minEngValue · 4 Bytes maxEngValue · 4 Bytes
Page 151 of the Perle Systems TS2 user manual — UDP Unicast Example
Page 151 · click to enlarge
Page 151

I/O UDP

Digital/Relay Data The digital data is in bit format, 1 meaning On and 0 (zero) meaning Off. Each channel has its own bit, in least significant bit order.

Data (1 Byte, one bit for each channel)

2 Bytes 1 Byte (in bits)

Channel4 Channel3 Channel 2 Channel 1

Serial Pin Signal Data The serial data is in bit format, 1 meaning On and 0 (zero) meaning Off. Each channel has its own bit, in the following order.

Data (1 Byte for each port, one bit for each signal)

2 Bytes 1 Byte (in bits)

RTS DTR CTS DCD DSR

The Data Exists field is 1 byte in least significant bit order, for each channel. If data exists for a channel, the bit will be 1, if no data exists for a channel (it is not configured), the bit will be 0 (zero).

Data Exists(1 Byte, one bit for each channel)

Channel4 Channel3 Channel 2 Channel 1

UDP Unicast Example

For an example of the I/O UDP unicast, see the sample program, ioudpbcast.c, found on your CD-ROM.

Length *Data Exists · Length *Data Exists · *Data Exits Field

Page 152 of the Perle Systems TS2 user manual — UID: 15
Page 152 · click to enlarge
Page 152

I/O Modbus Slave

If you have a Modbus serial or TCP application, it can access I/O connected to the IOLAN when the I/O Global Modbus Slave is enabled. You must supply a unique UID for the IOLAN, as it will act as a Modbus Slave.

Perle Systems TS2 — I/O Modbus Slave diagram (page 152)
Fig. 108 · I/O Modbus Slave

There are three ways your Modbus Application can connect to the IOLAN to access I/O.

Modbus Serial Application Connected to the Serial Port

Your Modbus serial application can be connected right to the IOLAN serial port to access I/O.

UID: 15

PC running a Modbus Serial

Modbus Serial Application Connected to the Network

If you want to access the I/O from a LAN connection, you can install TruePort on the PC running the Modbus serial application as described in TruePort I/O on page 158 and connect to the IOLAN over the network.

UID: 15

PC running a Modbus Serial

Show 13 more labels / short text on this page
I/O Modbus Slave · Serial · Power · perle · Device Server · I/O Digital Output · Application · Power · Network · perle · Device Server · I/O Digital Output · Application
Page 153 of the Perle Systems TS2 user manual — Function Codes
Page 153 · click to enlarge
Page 153

Modbus TCP Application

If you have a Modbus RTU or Modbus ASCII program, you can access the I/O by connecting to the IOLAN over the network.

UID: 15

PC running a Modbus RTU

Modbus I/O Access

The section defines the function codes and registers you will need to access the I/O through Modbus TCP, Modbus serial, or Modbus serial/TruePort.

Function Codes

The following function codes are supported by the IOLAN:

z 01 read coils

z 03 read multiple holding registers

z 04 read input registers

z 05 write coil

z 06 write single register

z 08 diagnostics (echo the request)

z 15 force multiple coils

z 16 write multiple registers

There are four Modbus data models:

Discrete Input Not used

Coils Digital Input (DI), Alarm state for DI, Digital Output (DO). All coils are Boolean values and are 1 byte.

Input Registers (IR) Analog Input (AI), Alarm state for AI. All Input Registers are 2 bytes long.

Holding Registers Status (R), Control value (R/W or W). Holding Registers with _ENG registers are 4 bytes long, all other Holding Registers are 2 bytes long.

All coil/register values are in decimal.

Show 7 more labels / short text on this page
Modbus I/O Access · Power · Network · perle · Device Server · I/O Digital Output · or ASCII Application
Page 154 of the Perle Systems TS2 user manual — I/O Coil/Register Descriptions
Page 154 · click to enlarge
Page 154

I/O Coil/Register Descriptions

This section contains descriptions of I/O coils:

z MB_REG_DI_SENSOR—Status of Digital input. 1 is Active, 0 is Inactive. If Invert Signal is configured on, 0 is Active, 1 is Inactive. If input is Latched, returns latched status.

z MB_REG_DI_SENSOR_ALARM_STATE—Indication if input is in alarm state. 1 is In Alarm state, 0 is Not in Alarm state. A write of any value clears the alarm state.

z MB_REG_DO_SENSOR—Status of Digital output. 1 is Active, 0 is Inactive. If Invert Signal is configured on, 0 is Active, 1 is Inactive.

This section contains descriptions of I/O holding registers:

z MB_REG_HR_DI_SENSOR_LATCH—The latch status of the Digital input. 1 is Latched, 0 is Not latched. A write of any value will clear the latch.

z MB_REG_HR_DO_SENSOR_PULSE_ISW—Inactive Signal Width. This is how long the channel will remain inactive during pulse mode in increments of 100ms. Valid values are 1-9999. The default is 1 (100 ms).

z MB_REG_HR_DO_SENSOR_PULSE_ASW—Active Signal Width. This is how long the channel will be active during the pulse mode in increments of 100ms. Valid values are 1-9999. The default is 1 (100 ms).

z MB_REG_HR_DO_SENSOR_PULSE_COUNT—The number of times the channel output will pulse. Each count consists of an active/inactive sequence. The default is 1 cycle.

z MB_REG_HR_AI_CLEAR_ALARM_LATCH—Used to reset a latched alarm state. A write of any value will clear the alarm latch for the specific Analog input.

z MB_REG_HR_AI_CLEAR_MAX—Used to reset the Analog input maximum value reached. A write of any value will reset the maximum.

z MB_REG_HR_AI_CLEAR_MIN—Used to reset the Analog input minimum value reached. A write of any value will reset the minimum.

This section contains descriptions of I/O input registers:

z MB_REG_IR_CURR_ENG—The current value of an Analog or Temperature input converted to appropriate units. For Analog, this will be in voltage or current, depending on the configuration. For the Temperature, this value will be in Celsius or Fahrenheit, depending on configuration.

z MB_REG_IR_MIN_ENG—The minimum converted value ever reached on this input since the IOLAN was re-started or a manual clear was issued.

z MB_REG_IR_MAX_ENG—The maximum converted value ever reached on this input since the IOLAN was re-started or a manual clear was issued.

z MB_REG_IR_CURR_RAW—The current raw value received from the Analog to Digital converter. This is a hexadecimal value in the range of 0 -0xFFFF.

z MB_REG_IR_MIN_RAW—The minimum raw value ever reached on this input since the IOLAN was re-started or a manual clear was issued.

z MB_REG_IR_MAX_RAW—The maximum converted value ever reached on this input since the IOLAN was re-started or a manual clear was issued.

z MB_REG_IR_ALARM_LEVEL—This gives the current alarm severity level for the corresponding Analog input. Severity levels range from 0 (not in alarm) to 5 (highest alarm severity).

Modbus I/O Access

Page 155 of the Perle Systems TS2 user manual — MB_REG_IR_CURR_ENG 2080 2112 2144 2176 R
Page 155 · click to enlarge
Page 155

Serial Port Coil/Register Descriptions

This section contains descriptions of serial port coils:

z MB_REG_DI_DSR—The status of the DSR input signal. 1 is Active, 0 is Inactive. If Invert Signal is configured on, 0 is Active, 1 is Inactive. If input is Latched, returns latched status.

z MB_REG_DI_DSR_ALARM_STATE—The alarm state of DSR input signal. 1 is In Alarm state, 0 is Not in Alarm state. A write of any value clears the alarm state.

z MB_REG_DI_DCD—The status of DCD line. 1 is Active, 0 is Inactive. If Invert Signal is configured on, 0 is Active, 1 is Inactive.

z MB_REG_DI_DCD_ALARM_STATE—The alarm state of DCD input signal. 1 is in Alarm state, 0 is Not in Alarm state. A write of any value clears the alarm state.

z MB_REG_DI_CTS—The status of CTS input signal. 1 is Active, 0 is Inactive. If Invert Signal is configured on, 0 is Active, 1 is Inactive.

z MB_REG_DI_CTS_ALARM_STATE—The alarm state of CTS input signal. 1 is Alarm, 0 is Not in Alarm. A write of any value clears the alarm state.

z MB_REG_DO_DTR—The status of DTR output signal. 1 is Active, 0 is Inactive.

z MB_REG_DO_RTS—The status of RTS output signal. 1 is Active, 0 is Inactive.

This section contains descriptions of serial port holding registers:

z MB_REG_HR_DI_DSR_LATCH—The latched status for the DSR signal. 1 is Latched, 0 is Not Latched. A write any value will clear the latch.

z MB_REG_HR_DI_DCD_LATCH—The latched status for the DCD signal. 1 is Latched, 0 is Not Latched. A write any value will clear the latch.

z MB_REG_HR_DI_CTS_LATCH—The latched status for the CTS signal. 1 is Latched, 0 is Not Latched. A write any value will clear the latch.

A4/T4 Registers

The following registers are supported by the IOLAN A4 and T4 Input models:

Data Model A1/T1 A2/T2 A3/T3 A4/T4 R/W

Holding Registers:

MB_REG_HR_AI_CLEAR_ALARM_LATCH 2049 2050 2051 2052 W

MB_REG_HR_AI_CLEAR_MAX 2113 2114 2115 2116 W

MB_REG_HR_AI_CLEAR_MIN 2177 2178 2179 2180 W

Input Registers:

MB_REG_IR_CURR_ENG 2080 2112 2144 2176 R

MB_REG_IR_MIN_ENG 2082 2114 2146 2178 R

MB_REG_IR_MAX_ENG 2084 2116 2148 2180 R

MB_REG_IR_CURR_RAW 2086 2118 2150 2182 R

MB_REG_IR_MIN_RAW 2087 2119 2151 2183 R

MB_REG_IR_MAX_RAW 2088 2120 2152 2184 R

MB_REG_IR_ALARM_LEVEL 2089 2121 2153 2185 R

Modbus I/O Access

Page 156 of the Perle Systems TS2 user manual — MB_REG_IR_CURR_ENG 2080 2112 2144 2176 ----- ----- R
Page 156 · click to enlarge
Page 156

A4D2/A4R2 Registers

The following coils and registers are supported by the IOLAN A4D2 and A4R2 I/O models:

Data Model A1 A2 A3 A4 D1/R1 D2/R2 R/W

Coils:

MB_REG_DI_SENSOR 6149 6150 R

* MB_REG_DI_SENSOR_ALARM_STATE 6213 6214 R/W

MB_REG_DO_SENSOR 6661 6662 R/W

Holding Registers:

MB_REG_HR_DI_SENSOR_LATCH 6149 6150 R/W

MB_REG_HR_DO_SENSOR_PULSE_ISW ----- ----- ----- ----- 6213 6214 R/W

MB_REG_HR_DO_SENSOR_PULSE_ASW ----- ----- ----- ----- 6277 6278 R/W

MB_REG_HR_DO_SENSOR_PULSE_COUNT ----- ----- ----- ----- 6341 6342 R/W

MB_REG_HR_AI_CLEAR_ALARM_LATCH 2049 2050 2051 2052 ----- ----- W

MB_REG_HR_AI_CLEAR_MAX 2113 2114 2115 2116 ----- ----- W

MB_REG_HR_AI_CLEAR_MIN 2177 2178 2179 2180 ----- ----- W

Input Registers:

MB_REG_IR_CURR_ENG 2080 2112 2144 2176 R

MB_REG_IR_MIN_ENG 2082 2114 2146 2178 ----- ----- R

MB_REG_IR_MAX_ENG 2084 2116 2148 2180 ----- ----- R

MB_REG_IR_CURR_RAW 2086 2118 2150 2182 ----- ----- R

MB_REG_IR_MIN_RAW 2087 2119 2151 2183 ----- ----- R

MB_REG_IR_MAX_RAW 2088 2120 2152 2184 ----- ----- R

MB_REG_IR_ALARM_LEVEL 2089 2121 2153 2185 ----- ----- R

*For DI alarm state, read will get state, write will clear alarm.

Modbus I/O Access

Page 157 of the Perle Systems TS2 user manual — MB_REG_HR_DI_DSR_LATCH 4097 R/W
Page 157 · click to enlarge
Page 157

D4/D2R2 Registers

The following coils and registers are supported by the IOLAN D4 and D2R2 I/O models:

Data Model D1 D2 D3/R1 D4/R2 R/W

Coils:

MB_REG_DI_SENSOR 6145 6146 6147 6148 R

* MB_REG_DI_SENSOR_ALARM_STATE 6209 6210 6211 6212 R/W

MB_REG_DO_SENSOR 6657 6658 6659 6660 R/W

Holding Registers:

MB_REG_HR_DI_SENSOR_LATCH 6145 6146 6147 6148 R/W

MB_REG_HR_DO_SENSOR_PULSE_ISW 6209 6210 6211 6212 R/W

MB_REG_HR_DO_SENSOR_PULSE_ASW 6273 6274 6275 6276 R/W

MB_REG_HR_DO_SENSOR_PULSE_COUNT 6337 6338 6339 6340 R/W

*For DI alarm state, read will get state, write will clear alarm.

Serial Pin Signals

The following coils and registers are supported by the IOLAN I/O models:

Data Model Pin R/W

Coils:

MB_REG_DI_DSR 4225 R

MB_REG_DI_DSR_ALARM_STATE 4289 R/W

MB_REG_DI_DCD 4353 R

MB_REG_DI_DCD_ALARM_STATE 4417 R/W

MB_REG_DI_CTS 4481 R

MB_REG_DI_CTS_ALARM_STATE 4545 R/W

MB_REG_DO_DTR 4673 R/W

MB_REG_DO_RTS 4737 R/W

Holding Registers:

MB_REG_HR_DI_DSR_LATCH 4097 R/W

MB_REG_HR_DI_DCD_LATCH 4609 R/W

MB_REG_HR_DI_CTS_LATCH 5121 R/W

Modbus I/O Access

Page 158 of the Perle Systems TS2 user manual — IOLAN
Page 158 · click to enlarge
Page 158

TruePort I/O

You can see a sample API I/O over TruePort program called ioapiotp.c on the CD-ROM.

TruePort/Modbus Combination

If you have a Modbus serial application running on a PC that is connected to a network, you can use TruePort as a virtual serial connection to communicate with the IOLAN over the network to access I/O data.

UID: 15

PC running a Modbus Serial

IOLAN

The host running TruePort must be in Modbus/ASCII or Modbus/RTU mode.

Show 6 more labels / short text on this page
TruePort I/O · Network Power · perle · Application/ · I/O Digital Output · TruePort
Page 159 of the Perle Systems TS2 user manual — IOLAN
Page 159 · click to enlarge
Page 159

API Over TruePort Only

If you have a custom application that talks to a serial port, you can use TruePort as a virtual serial port to communicate with the IOLAN over the network to access I/O data using the Perle API. See Accessing I/O Data Via TruePort on page 160 for more information on the API.)

IOLAN

The host running TruePort must be in I/O API mode.

Show 7 more labels / short text on this page
TruePort I/O · Network Power · perle · PC running · Custom Application (API)/ · I/O Digital Output · TruePort
Page 160 of the Perle Systems TS2 user manual — Setup
Page 160 · click to enlarge
Page 160

Accessing I/O Data Via TruePort

Accessing I/O Data Via TruePort

Introduction

Analog and Digital I/O data, as well as output control, can be accessed in several ways. To have access from an application running on a workstation or server, the I/O Applications Program Interface (API) provided within Trueport can be used. This API uses a command/response format to get or set data on each individual I/O channel register. A sample program (ioapiotp.c) demonstrating typical usage can be found on the IOLAN product CD-ROM.

Setup

After TruePort has been properly installed and configured on the workstation or server and initiated from the application, it will setup a connection to the appropriate IOLAN. It will then be available to relay commands to the IOLAN and communicate responses back the application. TruePort will create a COM port to which the application can write commands to and read responses from. Since all communications are done via this COM port, the application need only use standard serial communication interface calls.

The following steps should be taken:

1. Install the Trueport software on the server or workstation on which the application will be running.
2. Configure the virtual communication port (COM) (see TruePort User Guide for details)
3. Run the application. Typically the application will:
1. Open the COM port.
2. Send Commands to the COM port using standard write commands.
3. Read Responses from the COM port using standard read commands.
4. Once the desired operations are completed, the COM port can be closed.
Page 161 of the Perle Systems TS2 user manual — Response Format
Page 161 · click to enlarge
Page 161

Accessing I/O Data Via TruePort

Format of API Commands

There are two groups of commands:

z Get Commands—Retrieve values of the I/O channel registers

z Set Commands—Set values on the I/O channel registers.

I/O Channel registers are all assigned unique addresses, which need to be referenced in all of the commands. Please refer to the documentation specific you the applicable mode, for the list and addresses of all the registers.

Model Go to...

A4 A4/T4 Registers on page 155

T4 A4/T4 Registers on page 155

A4D2 A4D2/A4R2 Registers on page 156

A4R2 A4D2/A4R2 Registers on page 156

D4 D4/D2R2 Registers on page 157

D2/R2 D4/D2R2 Registers on page 157

Get Commands

The following tables show the general structure to be used for Get commands.

Command Format

Byte(s) # of Bytes Value

1 1 Command Code:

z 0x01 – Get “coils” (Boolean register)

z 0x03 – Get “holding registers” (R/W registers)

z 0x04 – Get “input registers” (R only register)

2-3 2 Starting register number (see A4/T4 Registers on page 155, A4D2/A4R2 Registers on page 156, or D4/D2R2 Registers on page 157 for this value).

4-5 2 Number of registers to read. If this value is greater than 1, the response will contain the values of multiple consecutive registers.

Response Format

Byte(s) # of Bytes Value

1 1 Command that this is a response to. If an error has been detected, the command value will have the high bit set (OR with 0x80). For example: The command is 0x04, so the command field in the response would be 0x84.

2 1 Length of data (in bytes) starting in next byte.

3-n n Requested register values.

Page 162 of the Perle Systems TS2 user manual — Command Format
Page 162 · click to enlarge
Page 162

Accessing I/O Data Via TruePort

Example 1: Read the status of the first digital input (DI1) on a D2R2 unit.

DI1 sensor is a coil register with the decimal value of 6145 (hex 0x1801).

Request0x01 0x18 0x01 0x00 0x01
Response0x01 0x01 0x 01 (Digital input 1 is active)

Example 2: Read the values for the Inactive Signal Width, Active Signal Width, and Pulse count for the second digital output (DO2) on a D4 unit.

DO2, Inactive Signal Width is a holding register with the decimal value of 6210 (hex 0x1842).

Request0x03 0x18 0x42 0x00 0x03
Response0x03 0x06 0x00 0x0A 0x00 0x11 0x00 0x0F

(Inactive =10*100ms, Active= 17*100ms, and Pulse count = 15)

Example 3: Read the raw current, minimum and maximum values of the third Analog input (A3) on an A4D2 unit.

A3 current raw value is an input register with the decimal value of 2150 (hex 0x0866).

Request0x04 0x08 0x86 0x00 0x03
Response0x04 0x06 0x10 0x03 0x0F 0x30 0x10 0x20

(Current = 0x1003, Minimum = 0x0F30, and Maximum = 0x1020)

Set Commands

The following tables show the general structure to be used for set commands.

Command Format

Byte(s) # of Bytes Value

1 1 Command Code (in hex):

z 0x0F – Set “Boolean registers” (R/W coils)

z 0x10 – Set “holding registers” (read/write registers)

2-3 2 Starting register number (see A4/T4 Registers on page 155, A4D2/A4R2 Registers on page 156, or D4/D2R2 Registers on page 157 for this value).

4-5 2 Number of registers to set. If this value is greater than 1, the response will contain the values of multiple consecutive registers.

6 1 The length of the data (in bytes) to be written to the registers.

7-n n Data to be written to the registers. If accessing registers which are 2 or 4 bytes, the data is in Network order (Big endian) format (that is, MSB, LSB). For Boolean registers, the value field will be a bit field with the LSBit corresponding to the IO channel referenced by the starting register.

Page 163 of the Perle Systems TS2 user manual — Unsuccessful Response Format
Page 163 · click to enlarge
Page 163

Accessing I/O Data Via TruePort

Successful Response Format

Byte(s) # of Bytes Value

1 1 Command code (from request).

2 2 Starting register number (see A4/T4 Registers on page 155, A4D2/A4R2 Registers on page 156, or D4/D2R2 Registers on page 157 for this value) from request.

4 2 Number of registers written.

Unsuccessful Response Format

Byte(s) # of Bytes Value

1 1 Command that this is a response to. If an error has been detected, the command value will have the high bit set (OR with 0x80). For example: The Command is 0x10, so the command field in the response would be 0x90.

1 1 Error code, see Error Codes on page 164.

Example 1: Turn on the first relay on a D2R2 unit.

The first relay (R1) is a digital out coil register with a decimal value of 6659 (hex 0x1A03).

Request0x0F 0x1A 0x03 0x00 0x01 0x01 0x01
Response0x0F 0x1A 0x03 0x00 0x01

Example 2: Turn on the first and second relay on a D2R2 unit.

The first relay (R1) is a digital out coil register with a decimal value of 6659 (hex 0x1A03).

Request: 0x0F 0x1A 0x03 0x00 0x02 0x01 0x03 (03 = “00000011” which sets R1 and R2 to 1)

Response0x0F 0x1A 0x03 0x00 0x02
Perle Systems TS2 — Unsuccessful Response Format diagram (page 163)
Fig. 109 · Unsuccessful Response Format
Page 164 of the Perle Systems TS2 user manual — I/O SNMP Traps
Page 164 · click to enlarge
Page 164

Error Codes

01 Illegal Function The function code received in the query is not an allowable action for the server (or slave).

02 Illegal Data Address

The data address received in the query is not an allowable address for the server (or slave).

03 Illegal Data Value A value contained in the query data field is not an allowable value for server (or slave).

04 Slave Device Failure

An unrecoverable error occurred while the server (or slave) was attempting to perform the requested action.

I/O SNMP Traps

When you enable SNMP traps for Digital and Analog inputs, a value is returned when an alarm triggers or clears. This section decodes the SNMP specific trap numbers. The value returned from the trap will be the I/O channel number that is generating the trap.

Trap # Alarm Description

0 IO_DI_ALARM_SENSOR Trap for the Digital input Trigger.

1 IO_DI_ALARM_SERIAL_DSR Trap for the Digital input DSR serial pin Trigger.

2 IO_DI_ALARM_SERIAL_DCD Trap for the Digital input DCD serial pin Trigger.

3 IO_DI_ALARM_SERIAL_CTS Trap for the Digital input CTS serial pin Trigger.

4 IO_AI_ALARM_LEVEL1 Trap for Analog input Alarm Level 1.

5 IO_AI_ALARM_LEVEL2 Trap for Analog input Alarm Level 2.

6 IO_AI_ALARM_LEVEL3 Trap for Analog input Alarm Level 3.

7 IO_AI_ALARM_LEVEL4 Trap for Analog input Alarm Level 4.

8 IO_AI_ALARM_LEVEL5 Trap for Analog input Alarm Level 5.

9 IO_DI_ALARM_SENSOR_CLEAR Trap for Digital input trigger Clear Mode.

10 IO_DI_ALARM_SERIAL_DSR_CLEAR Trap for Digital input DSR serial pin trigger Clear Mode.

11 IO_DI_ALARM_SERIAL_DCD_CLEAR Trap for Digital input DCD serial pin trigger Clear

Mode.

12 IO_DI_ALARM_SERIAL_CTS_CLEAR Trap for Digital input CTS serial pin trigger Clear Mode.

13 IO_AI_ALARM_LEVEL1_CLEAR Trap for the Analog input Alarm Level 1 Clear.

14 IO_AI_ALARM_LEVEL2_CLEAR Trap for the Analog input Alarm Level 2 Clear.

15 IO_AI_ALARM_LEVEL3_CLEAR Trap for the Analog input Alarm Level 3 Clear.

16 IO_AI_ALARM_LEVEL4_CLEAR Trap for the Analog input Alarm Level 4 Clear.

17 IO_AI_ALARM_LEVEL5_CLEAR Trap for the Analog input Alarm Level 5 Clear.

I/O SNMP Traps · Code Name Description · Specific

Page 165 of the Perle Systems TS2 user manual — Field Descriptions
Page 165 · click to enlarge
Page 165

Configuring the System Chapter 11 11

Introduction

Perle Systems TS2 — Configuring the System Chapter 11 11 diagram (page 165)
Fig. 110 · Configuring the System Chapter 11 11

This chapter describes the alerts (syslog) that can be configured for the IOLAN and the advanced options (SNMP, custom applications/plugins, and other miscellaneous configuration options) that you will want to look at to see if they are required for your implementation.

Alerts

Syslog

Overview The IOLAN can be configured to send system log messages to a syslog daemon running on a remote host if the Syslog service is activated. You can configure a primary and secondary host for the syslog information and specify the level for which you want syslog information sent.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 165)
Fig. 111 · Field Descriptions

Configure the following parameters:

Primary Host The first preconfigured host that the IOLAN will attempt to send system log messages to; messages will be displayed on the host’s monitor. Default: None

Page 166 of the Perle Systems TS2 user manual — Field Descriptions
Page 166 · click to enlarge
Page 166

Secondary Host If the IOLAN cannot communicate with the primary host, then the IOLAN will attempt to send system log messages to this preconfigured host; messages will be displayed on the host’s monitor. Default: None

Level Choose the event level that triggers a syslog entry. Data Options: Emergency, Alert, Critical, Error, Warning, Notice, Info, Debug Default: Emergency

Management

SNMP

Overview If you are using SNMP to manage/configure the IOLAN, or to view statistics or traps, you must set up a User in SNMP version 3 or a Community in SNMP version 1,2 to allow your SNMP manager to connect to the IOLAN; this can be done in the DeviceManager, WebManager, CLI, or Menu. You must then load the perle-ds.MIB (found on the CD-ROM packaged with the IOLAN) file into your SNMP manager before you connect to the IOLAN.

Field Descriptions

Perle Systems TS2 — Field Descriptions diagram (page 166)
Fig. 112 · Field Descriptions

Configure the following parameters:

Contact The name and contract information of the person who manages this SMNP node.

Location The physical location of the SNMP node.

Community The name of the group that devices and management stations running SNMP belong to.

Management

Page 167 of the Perle Systems TS2 user manual — Custom App/Plugin
Page 167 · click to enlarge
Page 167

Internet Address The IP address of the SNMP manager that will send requests to the IOLAN. If the address is 0.0.0.0, any SNMP manager with the Community Name can access the IOLAN.

Permissions Permits the IOLAN to respond to SNMP requests. Data Options:

z None—There is no response to requests from SNMP.

z Readonly—Responds only to Read requests from SNMP.

z Readwrite—Responds to both Read and Write requests from SNMP. Default: None

Read-Write User Specified user can view and edit SNMP variables.

Read-Only User Specified user can only view SNMP variables.

Trap The trap receiver is the network management system (NMS) that should receive the SNMP traps. This NMS must have the same SNMP community string as the trap sender.

Internet Address Defines the hosts (by IP address) that will receive trap messages generated by the IOLAN. Up to four trap hosts can be defined.

Custom App/Plugin

Overview You can create custom applications for the IOLAN by using the Perle SDK. See the SDK Programmer’s Guide (the SDK and guide are found on the Perle website at www.perle.com/downloads/index.shtml) for information about the functions that are supported. You must download the program and any ancillary files to the IOLAN and set the Serial Port Profile to Custom App/Plugin to run a custom application. You must also specify the program executable in the Command Line parameter.

A custom application or plugin can be run on the serial port. In this situation, the application will start once the serial port is activated and operate solely on the context of that serial port and any network communications related to that serial port. You could run a different custom application on each serial port. The serial port custom application or plugin is configured by specifying the Custom App/Plugin profile for the serial port.

The system level custom application or plugin will begin execution immediately following the system startup. It runs on the context of the whole system and can access network communications as well as any or all serial ports.

Management

Page 168 of the Perle Systems TS2 user manual — Login Tab Field Descriptions
Page 168 · click to enlarge
Page 168

Field Description

Perle Systems TS2 — Field Description diagram (page 168)
Fig. 113 · Field Description

Configure the following parameter:

Command Line The name of the application that has been already been downloaded to the IOLAN, plus any parameters you want to pass to the program. For example, using sample outraw program (this is sample program supplied with the SDK), you would type:

outraw -s 0 192.168.2.1:10001 Acct:10001 if you were starting the application on the Server (notice the -s 0 parameter specifies serial port 1 to this particular application). Field Format: Maximum of 80 characters

Advanced

Overview Review the configuration options in the Advanced page to determine if any of them apply to your implementation.

Login Tab Field Descriptions

Perle Systems TS2 — Login Tab Field Descriptions diagram (page 168)
Fig. 114 · Login Tab Field Descriptions

Configure the following parameters:

Use System Name in Prompts

Displays the System Name field value instead of default product name. When enabled, the Server Name is displayed in the IOLAN login prompt, CLI prompt, WebManager login screen, and the heading of the Menu. Default: Disabled

This parameter concerns the banner information (product name/software version). This banner information is presented to a user with a login prompt. For security reasons, you can turn off the display of this information. Default: Disabled

Use Custom Login Prompt

When set, and a custom language file is in use, the login prompt will use the string defined in the language file as the login prompt instead of the default prompt, login:. Default: Disabled

Management · Display Login Banner

Page 169 of the Perle Systems TS2 user manual — Advanced
Page 169 · click to enlarge
Page 169

When set, authorized users who do not have a password set, with the exception of the Admin user, WILL NOT be prompted for a password at login with Local Authentication. Default: Disabled

The number of attempts a user is allowed to enter a password for a serial port connection from the network. If this limit is exceeded, the serial port is disabled for 5 minutes. A user with Admin level rights can restart the serial port, bypassing the timeout, by issuing a kill on the disabled serial port. Default: 3

Bootup Files Tab Field Descriptions You must have a TFTP server running on any host that you are uploading or downloading files to/from. When you specify the file path, the path must be relative to the default path set in your TFTP server software.

Perle Systems TS2 — Advanced diagram (page 169)
Fig. 115 · Advanced

Configure the following parameters:

Firmware Host The host name or IP address of the server that contains the firmware file. If you use a host name, it must exist in the IOLAN’s host table or be resolved by DNS.

Firmware File The path and file name, relative to the default path of your TFTP server software, of the update software for the IOLAN that will be loaded when the IOLAN is rebooted.

Configuration Host The host name or IP address of the server that contains the configuration file. If

you use a host name, it must exist in the IOLAN’s host table or be resolved by DNS.

Configuration File The path and file name, relative to the default path of your TFTP server

software, of the configuration file for the IOLAN that will be loaded when the IOLAN is rebooted.

Management · Bypass Login Password · Password Retry Limit

Page 170 of the Perle Systems TS2 user manual — Advanced
Page 170 · click to enlarge
Page 170

Message of the Day (MOTD) Tab Field Descriptions You must have a TFTP server running on any host that you are uploading or downloading files to/from when using TFTP. When you specify the file path, the path must be relative to the default path set in your TFTP server software. You can download a MOTD file to the IOLAN in the DeviceManager by selecting Tools, Advanced, Custom Files and then selecting the Download Other File option and browse to the MOTD file. In WebManager, select Administration, Custom Files and select the Other File option and browse to the MOTD file. After the MOTD is downloaded to the IOLAN, you must specify the MOTD file name in the Filename field to access it as the message of the day (no TFTP Host parameter is required when the file is internal).

Perle Systems TS2 — Advanced diagram (page 170)
Fig. 116 · Advanced

Configure the following parameters:

TFTP Host The host that the IOLAN will be getting the Message of the Day file from.

Filename The path and file name, relative to the default path of your TFTP server software, of the file that contains a string that is displayed when a user connects to the IOLAN. The IOLAN will look for the file internally (it must already be downloaded), if only the file is specified (no host) or the file cannot be found on the specified host.

TFTP Tab Field Descriptions You must have a TFTP server running on any host that you are uploading or downloading files to/from.

Perle Systems TS2 — Advanced diagram (page 170)
Fig. 117 · Advanced

Configure the following parameters:

Retry The number of times the IOLAN will retry to transmit a TPFT packet to/from a host when no response is received. A value of 0 (zero) means that the IOLAN will not attempt a retry should TFTP fail. Range: 0-5 Default: 5

Timeout The time, in seconds, that the IOLAN will wait for a successful transmit or receipt of TFTP packets before retrying a TFTP transfer. Range: 3-10 Default: 3 seconds

Management

Page 171 of the Perle Systems TS2 user manual — Overview
Page 171 · click to enlarge
Page 171

Controlling the I/O Channels Chapter 12 12

Introduction

The Control section appears when the IOLAN is connected to an I/O model.

I/O Channels

Overview

When the DeviceManager is connected to an I/O model IOLAN, the I/O Status/Control option is available. You can view the I/O status and manually control such options as clearing alarms, clearing minimum/maximum values, resetting the channel(s), and activating/deactivating output.

Perle Systems TS2 — Overview diagram (page 171)
Fig. 118 · Overview

The following buttons are available:

Resets the highlighted channel (click on a channel to highlight it).

Clears the alarm. Note that if the condition that tripped the alarm still exists, the alarm will not look like it’s cleared, but will reflect the appropriate alarm level severity. Alarm Level 0 means that the alarm has not been triggered.

Clear Latched Input Button

Clears the latched value.

Clear Minimum Value Button

Clears the minimum value.

Clear Maximum Value Button

Clears the maximum value.

Reset Channel Button · Clear Alarm Button

Page 172 of the Perle Systems TS2 user manual — Controlling the I/O Channels
Page 172 · click to enlarge
Page 172

Manually activates the channel output.

Manually deactivates the channel output.

Reset All Channels Button

Resets all the channels.

Refresh Button Resets the highlighted channel (click on a channel to highlight it).

I/O Channels · Activate Output Button · Deactivate Output Button

Page 173 of the Perle Systems TS2 user manual — Downloading Configuration Files
Page 173 · click to enlarge
Page 173

System Administration Chapter 13 13

Introduction

This chapter addresses the functions that the Admin user or a user with Admin Level privileges might do. This chapter uses the DeviceManager as the configuration method described in most administrative functions. As a general rule, administrative functions are accessed from the menu bar in the DeviceManager and under the Administration option in the WebManager’s navigation tree.

Managing Configuration Files

Saving Configuration Files

When you connect to the IOLAN using either DeviceManager or WebManager, the IOLAN’s active configuration file is loaded into the configurator. To save a backup of the configuration file locally, do the following:

z In DeviceManager, select File, Save As from the menu bar. Notice that you can save the file as either a .dme or a .txt file. Either file format can be imported into the DeviceManager and downloaded to the IOLAN in the future. The .dme is a binary file and the .txt file is a text file that can be viewed in any text editor.

z In WebManager, select under the Administration option, select Backup/Restore. Click the Backup button.

Downloading Configuration Files

You can download a configuration file to the IOLAN by doing the following:

z In DeviceManager:

1. Connect to the IOLAN to retrieve the current configuration file.
2. Open the configuration file you want to download to the IOLAN by selecting File , Import Configuration from a File and then browsing to the configuration file. This will replace the retrieved configuration file.
3. Select Tools , Download Configuration to IOLAN or click the Download All Changes button.
4. Reboot the IOLAN.

z In WebManager:

1. Under the Administration option, select Backup/Restore .
2. Browse to the configuration file that you want to download to the IOLAN.
3. Click the Restore button.
4. Reboot the IOLAN.
Page 174 of the Perle Systems TS2 user manual — Downloading Configuration Files to Multiple IOLANs
Page 174 · click to enlarge
Page 174

Downloading Configuration Files to Multiple IOLANs

You can download a configuration file to multiple IOLANs at the same time by doing the following in DeviceManager (DeviceManager is the only configurator that does this function):

1. Select Tools , Download Configuration to Multiple IOLAN s .
2. Specify the IOLANs that you want to download the configuration to:
Perle Systems TS2 — Downloading Configuration Files to Multiple IOLANs diagram (page 174)
Fig. 119 · Downloading Configuration Files to Multiple IOLANs

Enter the following information for each IOLAN that you want to configure with the same configuration file:

IP Address Enter the IP address of the IOLAN that you want to download the configuration to.

Server Name The name of the IOLAN. The IOLAN name that you put in this field is passed into the configuration before it is downloaded to the IOLAN and cannot be left blank.

Password Enter the Admin user password for the IOLAN.

Reboot Server Determines whether or not the IOLAN is rebooted after it has received the new configuration. The new configuration definitions will not go into effect until the IOLAN is rebooted.

3. Click Add to add the IOLAN to the download list. You can also click on the IOLAN entry and edit any information and then click Update to make the edits permanent.

Managing Configuration Files

Page 175 of the Perle Systems TS2 user manual — Downloading IOLAN Firmware
Page 175 · click to enlarge
Page 175
4. Click the Download> button to start the download process. A status window will display with the configuration download status.
Perle Systems TS2 — Uploading Configuration Files diagram (page 175)
Fig. 120 · Uploading Configuration Files

Uploading Configuration Files

When you upload a configuration to the DeviceManager, you are uploading the IOLAN’s working configuration file. In most other configurators (the exception being SNMP), you are always seeing the working configuration file.

In DeviceManager, select Tools, Upload Configuration from IOLAN. The working configuration file will automatically be loaded into the DeviceManager.

Downloading IOLAN Firmware

To upgrade the IOLAN firmware (software):

z In DeviceManager, select Tools, Advanced, Download Firmware to IOLAN. You can browse to the firmware location. Once the firmware download is complete, you will be prompted to reboot the IOLAN. You can choose to reboot the IOLAN at another time by selecting Tools, Reset, Reboot IOLAN.

z In WebManager, under the Administration option, select Update Firmware. Either browse to the firmware file and then click the Upload button or configure the TFTP server and click the Upload button. Note: If you use the TFTP option, the specified TFTP server must be on the same subnet as the IOLAN.

Upgrading the firmware does not affect the IOLAN’s configuration file or downloaded custom files.

Downloading IOLAN Firmware

Page 176 of the Perle Systems TS2 user manual — Calibrating Temperature Input
Page 176 · click to enlarge
Page 176

Calibrating I/O

All I/O channels are factory calibrated and should not need recalibration during initial use. However should calibration be required, you can recalibrate in DeviceManager or WebManager. In DeviceManager, you calibrate the I/O channel(s) by selecting Tools, I/O Channels, Calibrate. In WebManager, you calibrate the I/O channel(s) by selecting I/O Channels, Calibrate.

Calibrating Analog Input

To calibrate an Analog input channel, read the section that applies to the type of input you are calibrating. Note that calibration will be done for the active channel configuration; for example, if Channel A1 is set to voltage, you cannot calibrate it for current. The voltage range configured for this channel will also dictate what is being calibrated. For example, if this channel is configured for a range of +/-10V, calibrating this channel will calibrate all channels which are configured for +/-10V. During the calibration process, you will be asked to apply the minimum and maximum configured range value to the channel; for example, to calibrate for voltage +/- 10V, you will be prompted to first apply -10V and then +10V to the channel.

Also, you cannot actively calibrate disabled channels (although, for Voltage, if you enable the channel and then set it for a range that has already been calibrated for another channel, it will also be calibrated).

Calibrating Voltage When calibrating the IOLAN Analog input for voltage, you will need a calibration meter that is better than .1% volts precision. When you calibrate one channel, all voltage channels are automatically calibrated for that range; if another channel is set for a different range, you will need to calibrate that channel separately, but all channels that use that range are also automatically calibrated.

Calibrating Current When calibrating the IOLAN Analog input for current, you will need a calibration meter that is better than .1% current precision. Each channel needs to be calibrated individually.

Calibrating Temperature Input

To calibrate an Analog (Temperature) input channel, read the section that applies to the type of input you are calibrating. Note that calibration will be done for the active channel configuration; for example, if Channel A1 is set to thermocouple, you cannot calibrate it for RTD. During the calibration process, you will be asked to apply the minimum and maximum range value to the channel in either mV or Ohms; for example, to calibrate for thermocouple J 0 to 760C, you will be prompted to first apply -80mV and then +80mV to the channel.

Also, you cannot actively calibrate disabled channels (although if you enable the channel and then set it for the type of thermocouple or RTD that has already been calibrated on another channel, it will also be calibrated).

Calibrating Thermocouple When calibrating the IOLAN Analog input for thermocouple, you will need a calibration meter that is better than .15% accuracy. When you calibrate one channel, all thermocouple channels are automatically calibrated for that range; if another channel is set for a different range, you will need to calibrate that channel separately, but all channels that use that range are automatically calibrated.

Calibrating I/O

Page 177 of the Perle Systems TS2 user manual — Calibrating Analog Channels
Page 177 · click to enlarge
Page 177

Calibrating RTD When calibrating the IOLAN Analog input for RTD, you will need a resistor that is better than .05% Ohms accuracy. When you calibrate one channel, all RTD channels are automatically calibrated for that range; if another channel is set for a different range, you will need to calibrate that channel separately, but all channels that use that range are automatically calibrated.

Calibrating Analog Channels

Analog Input can be calibrated for Analog and Temperature IOLAN models.

Perle Systems TS2 — Calibrating Analog Channels diagram (page 177)
Fig. 121 · Calibrating Analog Channels

Select the channel you want to calibrate. This example uses an A4 model that has channel A1 set to Current with a Range of 0 to 20mA.

If you have not disabled confirmation messages (Tools, Options in DeviceManager only), you will get prompted to verify channel calibration.

Perle Systems TS2 — Calibrating Analog Channels diagram (page 177)
Fig. 122 · Calibrating Analog Channels

Click Yes to proceed with calibration. You are now prompted to apply 0 mA to the positive (+) and negative (-) terminals. Once that is done, click Yes to proceed.

Perle Systems TS2 — Calibrating Analog Channels diagram (page 177)
Fig. 123 · Calibrating Analog Channels

You are now prompted to apply 20 mA to the positive (+) and negative (-) terminals. Once that is done, click Yes to proceed.

Perle Systems TS2 — Calibrating Analog Channels diagram (page 177)
Fig. 124 · Calibrating Analog Channels

Once calibration is successfully completed, click OK to finish the process.

Perle Systems TS2 — Calibrating Analog Channels diagram (page 177)
Fig. 125 · Calibrating Analog Channels

Calibrating I/O

Page 178 of the Perle Systems TS2 user manual — Rebooting the IOLAN
Page 178 · click to enlarge
Page 178

Setting the IOLAN’s Date and Time

Resetting Calibration Data

You can reset the I/O channels calibrations to the factory calibrations in DeviceManager by selecting Tools, I/O Channels, Reset Calibrate Data or in WebManager by selecting Administration, Reset, I/O Calibration.

Setting the IOLAN’s Date and Time

When you set the IOLAN’s time, the connection method and time zone settings can affect the actual internal clock time that is being set. For example, if you are connecting to the IOLAN through the DeviceManager and your PC’s time zone is set to Pacific Standard Time (GMT -8:00) and the IOLAN’s time zone is set to Eastern Standard Time (GMT -5:00), the IOLAN’s time is actually three hours ahead of your PC’s time. Therefore, if you set the IOLAN’s time to 2:30 pm in the DeviceManager, the IOLAN’s actual internal clock time is 5:30 pm. This is the only configuration method that interprets the time and converts it between time zones, as necessary.

All other configuration methods set the IOLAN’s internal clock time to the time specified, with no interpretation.

To set the IOLAN’s system clock in DeviceManager, select Tools, Advanced, Set Unit Time/Date. The Set Date/Time window is displayed.

Perle Systems TS2 — Setting the IOLAN’s Date and Time diagram (page 178)
Fig. 126 · Setting the IOLAN’s Date and Time

Configure the following parameters:

Date The IOLAN’s date. The format of the IOLAN’s date is dependent on the Windows operating system and regional settings.

Time The IOLAN’s internal clock time, based on your PC’s time zone. For example, if your PC’s time zone is set to Pacific Standard Time (GMT -8:00) and the IOLAN’s time zone is set to Eastern Standard Time (GMT -5:00), the IOLAN’s time is three hours ahead of your PC’s time. If you set the IOLAN’s time to 2:30 pm, the IOLAN’s actual internal clock time is 5:30 pm.

Use the PCs Date/Time

When enabled, sets the IOLAN’s time to the PCs time. Default: Enabled

This option is unique to the DeviceManager.

Rebooting the IOLAN

When you download any file (configuration, keys, certificates, firmware, etc.) to the IOLAN, you must reboot the IOLAN for it to take effect by selecting Tools, Reset, Reboot Server in DeviceManager and Administration, Reboot Unit in WebManager.

Page 179 of the Perle Systems TS2 user manual — Loading a Supplied Language
Page 179 · click to enlarge
Page 179

Resetting the IOLAN to Factory Defaults

Resetting the IOLAN to Factory Defaults

You can reset the IOLAN to its factory default configuration by selecting Tools, Reset, Reset to Factory Default in DeviceManager and Administration, Reset, Factory Defaults in WebManager. The IOLAN will automatically reboot itself with the factory default configuration.

Language Support

Two language files, in addition to English, are supplied on the supplemental CD, French and German. You can use any of these language files to create a translation into a language of your choice. You can download the language file (whether the language is supplied or translated) into the IOLAN and select the Language option of Custom Language or Customlang (custom language), making the Menu and CLI field labels display in the desired language.

You can view Menu or CLI in one other language only (as well as English). If you download another language file, this new language will replace the first language you downloaded.

You can revert to English at any time; the English language is stored permanently in the IOLAN and is not overwritten by your new language. Each user logged into the IOLAN can operate in either English or the downloaded language.

Loading a Supplied Language

This section describes how to download a language file using the CLI, since it is the least intuitive method. French and German language files are provided on the supplemental CD.

To load one of the supplied languages into the IOLAN, so the Menu or CLI fields appear in another language, do the following:

1. Open the supplemental CD and identify the language file, either Iolan_ds_French.txt or Iolan_ds_German.txt , or supply one of your own translated files.
2. Copy the language file to a host machine on the network; place it in the main file system or on the main hard drive.
3. Either use the TFTP defaults in the IOLAN or, configure as necessary, TFTP in the IOLAN.
4. In the CLI of the IOLAN, enter the host IP address and file name; for example,

netload customlang 172.16.4.1 /temp/Iolan_ds_French.txt

The IOLAN will download the language file via TFTP.

In DeviceManager select Tools, Advanced, Custom Files and then select Download Custom Language File and browse to the language file. In WebManager select Administration, Custom Files and then specify the Custom Language File option and browse to the language file.

5. To set an individual user to the new language, go to the Users menu and, in the Language field select Customlang . In the CLI (only) you can set individual users or all users to the new language; see the set user * command.
6. The user will see the change of language when he/she logs out ( Main Menu , Sessions Menu , Logout ) and logs back into the IOLAN. If, as Admin user, you change your language setting to Customlang , you will see the text menus display in the new language when you save and exit the Change User form. Users with Level Normal can also change their display language.
Page 180 of the Perle Systems TS2 user manual — Software Upgrades and Language Files
Page 180 · click to enlarge
Page 180

Translation Guidance

To help you with your translation, of supplied ASCII text language files we offer the following guidance:

z The IOLAN will support languages other than English (and the supplied German and French languages). The English language file, english.txt, displays the character length of each line at the beginning of the line. If a translated line goes over that character length, it will be displayed truncated in the Menu or CLI.

z Translate line for line, do not omit lines if you do not know the translation; leave the original untranslated text in place. Also, you must maintain the same sequential order of lines. It is a good practice to translate the file using a text editor that displays line numbers, so you can periodically verify that the line sequence has not changed from the original file (by comparing it to the original file).

z Keep all translations in quotes, otherwise the line will not display properly.

z Each line must end with a carriage return.

z If a line contains only numbers, for example 38400, leave that line in place, unchanged (unless you are using a different alphabet).

Software Upgrades and Language Files

If you receive a software upgrade for the IOLAN, the language files supplied on the supplemental diskette/CD might also have been updated. We will endeavour to provide a list of those changes in another text file on the same supplemental CD.

If you are already using one of the supplied languages, French or German, you probably want to update the language file in the IOLAN. Until you update the IOLAN with the new language file, new text strings will appear in English.

If you are already using a language translated from an earlier version, you probably want to amend your translation. When a language file is updated, we will try to maintain the following convention:

1. New text strings will be added to the bottom of the file (not inserted into the body of the existing file).
2. Existing text strings, if altered, will be altered in sequence; that is, in their current position in the file.
3. The existing sequence of lines will be unchanged.
4. Until you have the changes translated, new text strings will appear in the Menu or CLI in English.

Language Support

Page 181 of the Perle Systems TS2 user manual — Creating Terminal Definition Files
Page 181 · click to enlarge
Page 181

Downloading Terminal Definitions

All terminal types can be used on the IOLAN. Some terminal types which are not already defined in the IOLAN, however, are unable to use Full Screen mode (menus) and may not be able to page through sessions properly. When installed, the IOLAN has several defined terminal types—Dumb, WYSE60, VT100, ANSI, TVI925, IBM3151, VT320, and HP700.

If you are not using, or cannot emulate, any of these terminal types, you can add up to three additional terminal definitions to the IOLAN. The terminal definitions can be downloaded from a TCP/IP host.

To download terminal definitions, follow these steps:

1. Decide which TCP/IP host you are going to use. It must be a machine with enabled.
2. Configure TFTP in the IOLAN as necessary.
3. Select Tools , Advanced , Custom Files from the menu bar.
4. From the File Type drop-down, select Download Terminal Definition . Select the terminal definition option 1 , 2 , or 3 and then browse to the terminal definition file that is being downloaded to the IOLAN.
5. In the Terminal profile, select the Terminal Type Term x that you custom defined.

Creating Terminal Definition Files

To create new terminal definition files, you need to copy and edit the information from the terminfo database.

1. On a UNIX host, change directory to /usr/lib/terminfo/ x (where x is the first letter of the required terminal type). For a Wyse60, for example, you would enter the command cd /usr/lib/terminfo/w .
2. The termcap files are compiled, so use the command infocmp termfile to read the required file (for example: infocmp wy60 ).
3. Check the file for the attribute xmc# n (where n is greater than or equal to 1). This attribute will corrupt menu and form displays making the terminal type unsuitable for using Menu mode.
4. If the terminal definition is suitable, change to a directory of your choice.
5. Rename and copy the file to the directory specified at step 4. using the command infocmp termfile > term n where n is greater than or equal to 1; (for example, infocmp wy50 > term1 ). Make sure the file has global read and execute permission for its entire path.
6. Edit the file to include the following capabilities in this format:

term= acsc= bold= civis= clear= cnorm= cup= rev= rmacs= rmso= smacs= smso= page= circ=

Downloading Terminal Definitions

Page 182 of the Perle Systems TS2 user manual — Resetting Configuration Parameters
Page 182 · click to enlarge
Page 182

For example:

term=AT386 | at386| 386AT |386at |at/386 console acsc=jYk?lZm@qDtCu4x3 bold=\E[1m civis= clear=\E[2J\E[H cnorm= cup=\E[%i%p1%02d;%p2%02dH rev=\E4A rmacs=\E[10m rmso=\E[m smacs=\E[12m smso=\E[7m page= circ=n

Note: As you can see from the example, capabilities which are not defined in the terminfo file must still be included (albeit with no value). Each entry has an 80 character limit. On some versions of UNIX, some of the capabilities are appended with a millisecond delay (of the form $). These are ignored by the IOLAN and can be left out. The ‘acsc’ capability, if defined, contains a list of character pairs. These pairs map the characters used by the terminal for graphics characters to those of the standard (VT100) character set. Include only the following character pairs: jx, kx, lx, mx, qx, tx, ux and xx (where x must be substituted by the character used by the terminal). These are the box-drawing characters used to display the forms and menus of Menu mode. They must be entered in this order. The last two capabilities will not be found in the terminfo file. In the page field you must enter the escape sequence used by the terminal to change screens. The circ field defines whether the terminal can use previous page and next page control sequences. It must be set to y or n. These capabilities can be found in the documentation supplied with the terminal.

Resetting Configuration Parameters

You can reset the IOLAN to its factory settings through any of the following methods:

z You can push in the recessed button at the back of the IOLAN hardware for more than three seconds (pushing it in and then quickly releasing will just reboot the IOLAN)

z DeviceManager, select Tools, Reset, Reset to Factory Defaults

z CLI, at the command line type, reset factory

z WebManager, select Administration, Reboot Unit, and then click the Reboot button

z Menu, select Network Configuration, Reset to Factory Defaults

z SNMP, in the adminInfo folder, Set the adminFunction variable to 2

Resetting Configuration Parameters

Page 183 of the Perle Systems TS2 user manual — Lost Admin Password
Page 183 · click to enlarge
Page 183

Lost Admin Password

If the Admin user password is lost, there are only two possible ways to recover it:

z reset the IOLAN to the factory defaults

z have another user that has admin level rights, if one is already configured, reset the Admin password

Lost Admin Password

Page 184 of the Perle Systems TS2 user manual — Lost Admin Password
Page 184 · click to enlarge
Page 184

Lost Admin Password

Page 185 of the Perle Systems TS2 user manual — Virtual Modem AT Commands Appendix A A
Page 185 · click to enlarge
Page 185

Virtual Modem AT Commands Appendix A A

Virtual Modem Initialization Commands

You can initialize the modem connection using any of the following commands:

ATQn Quite mode. Determines if result codes will be sent to the connected terminal. Basic results codes are OK, CONNECT, RING, NO CARRIER, and ERROR. Setting quite mode also suppresses the "RING" message for incoming calls.

n=0, no result codes will be sent. n=1, result codes will be sent. (default)

ATVn Verbose mode. Determines if result codes are displayed as text or numeric values.

n=0, display as numeric values. n=1, display as text. (default)

ATEn Echo mode. Determines whether characters sent from the serial device will be echoed back by the IOLAN when VModem is in "command" mode.

n=0, disable echo. n=1, enable echo. (default)

+++ATH Hang up. This command instructs the IOLAN to terminate the current session and go into "command" mode.

ATA Answer call. Instructs the VModem to accept connection requests. VModem will give the terminal up to 3 minutes to answer the call. If the ATA is not received within 3 minutes, all pending sync messages will be discarded.

ATI0 Return the modem manufacturer name.

ATI3 Return the modem model name.

ATS0 Sets the value of the S0 register. The S0 register controls the "auto answer" behavior. In "manual" mode, the IOLAN will not accept incoming sessions until an ATA is issued by the serial device. In "auto answer" mode, the IOLAN will automatically accept an incoming connection request.

Register=0, sets "manual answer" mode Register=1-255, "auto answer" mode (default)

Command Description Options

Page 186 of the Perle Systems TS2 user manual — Virtual Modem AT Commands
Page 186 · click to enlarge
Page 186

Virtual Modem Initialization Commands

AT&Z1 Set command allows the user to store an IP address and port number or phone number to use when making a connection. The user will issue an ATDS1 to cause the IOLAN to initiate the connection.

AT&Sn Sets the behavior of IOLAN’s DTR signal. (DSR from a DCE perspective)

n=0, DTR signal always high. (default) n=2, DTR signal acts as DCD. n=3, DTR signal acts as RI.

AT&Rn Sets the behavior of IOLAN’s RTS signal. (CTS from a DCE perspective) If line is configured for hardware flow control, the RTS is used for this purpose and the setting of this command is ignored.

n=0, RTS always high. (default). n=3, RTS signal acts as DCD. n=4, RTS signal acts as RI.

AT&Cn Sets the behaviour of the DCD signal. n=0, DCD always on. n=1, DCD follows state of connection (off when no connection, on when TCP connection exists). (default)

AT&F Sets the modes back to the factory defaults. This is a hard-coded default configuration which does not look at any user configuration.

ATS2 Sets the value of the S2 register. The S2 register controls which character is used to enter "command" mode. (this is the potential replacement for the +++ (default) in front of the ATH command). This register will hold the hex value of the "escape" character. Any value > 27 will disable the ability to escape into "command" mode.

ATS12 Sets the value of the S12 register. The S12 register controls the minimum length of idle time which must elapse between the receipt of the escape character and the A (first character of the ATH sequence). Units are 1/50th of a second. The default is 50 = 1 second.

ATO (ATD with no phone number) Establishes a connection using the IP and port specified in the telephone number field.

ATDS1 Establishes a connection using the IP and port (or phone number) specified in the Phone Number field (stored by the AT&Z1 command).

Command Description Options

Page 187 of the Perle Systems TS2 user manual — 18 RTS+
Page 187 · click to enlarge
Page 187

Pinouts and Cabling Diagrams Appendix B B

Serial Pinouts

DB25 Male

This section defines the pinouts for the DB25 male connection used on the 1-port IOLAN.

Perle Systems TS2 — DB25 Male diagram (page 187)
Fig. 127 · DB25 Male

Pin 25 Pin 14

The following table provides pinout information:

EIA-232

EIA-422

1 Shield

7 GND

12 Power in Power in Power in Power in

13 CTS-

14 TxD+ TxD+ DATA+

18 RTS+

19 RTS-

Show 12 more labels / short text on this page
Pin 1 · Pin 13 · Pinout · EIA-485 Full Duplex · EIA-485 Half Duplex · 2 (out) TxD · 3 (in) RxD · 4 (out) RTS · 5 (in) CTS · 6 (in) DSR · 8 (in) DCD · 15 TxD- TxD- DATA-
Page 188 of the Perle Systems TS2 user manual — 13 RTS-
Page 188 · click to enlarge
Page 188

EIA-232

EIA-422

25 CTS+

The power in pin, pin 12, can be 9-30V DC.

DB25 Female

This section defines the pinouts for the DB25 female connection used on the 1-port IOLAN.

Perle Systems TS2 — DB25 Female diagram (page 188)
Fig. 128 · DB25 Female

Pin 14 Pin 25

The following table provides pinout information:

EIA-232

EIA-422

1 Shield

7 GND

12 Power in Power in Power in Power in

13 RTS-

18 CTS+

19 CTS-

Show 21 more labels / short text on this page
Serial Pinouts · Pinout · EIA-485 Full Duplex · EIA-485 Half Duplex · 20 (out) DTR · 21 RxD+ RxD+ · 22 RxD- RxD- · Pin 13 · Pin 1 · Pinout · EIA-485 Full Duplex · EIA-485 Half Duplex · 2 (in) RxD · 3 (out) TxD · 4 (in) CTS · 5 (out) RTS · 6 (out) DTR · 8 (in) DCD · 14 RxD+ RxD+ · 15 RxD- RxD- · 20 (in) DSR
Page 189 of the Perle Systems TS2 user manual — 7 6 GND GND GND GND
Page 189 · click to enlarge
Page 189

EIA-232

EIA-422

21 TxD+ TxD+ DATA+

25 RTS+

The power in pin, pin 12, can be 9-30V DC.

RJ45

This section defines the pinouts for the RJ45 connection used on the DS and TS IOLAN. The TS IOLAN does not support power in, so use the 8-pin mappings for this model. These pinouts do not apply to I/O models.

Pin 10 Pin 1

The following table provides pinout information:

Pinout 10-pin Pinout 8-pin EIA-232

EIA-422

1 Power In Power In Power In Power In

2 (in) 1 DCD

3 (out) 2 RTS TxD+ TxD+ DATA+

4 (in) 3 DSR

5 (out) 4 TxD TxD- TxD- DATA-

6 (in) 5 RxD RxD+ RxD+

7 6 GND

8 (in) 7 CTS RxD- RxD-

The power in pin, Pin 1, can be 9-30V DC. The 2-port IOLAN has power in on Port 2 only.

Pinouts and Cabling Diagrams 189

Show 7 more labels / short text on this page
Serial Pinouts · Pinout · EIA-485 Full Duplex · EIA-485 Half Duplex · 22 TxD- TxD- DATA- · EIA-485 Full Duplex · EIA-485 Half Duplex
Page 190 of the Perle Systems TS2 user manual — 5 GND GND GND
Page 190 · click to enlarge
Page 190

DB9 Male (Serial Only)

This section defines the pinouts for the DB9 male connection used on the 1-port IOLAN that is serial only (not I/O).

The following table provides pinout information:

2 (in) RxD RxD+

3 (out) TxD TxD+ TxD+/RxD+

5 GND GND GND

6 (in) DSR RxD-

7 RTS

DB9 Male I/O

This section defines the pinouts for the DB9 male connection used on the 1-port IOLAN I/O models.

The following table provides pinout information:

2 (in) RxD RxD+

3 (out) TxD TxD- TxD-/RxD-

5 GND GND GND

6 (in) DSR RxD-

7 RTS TxD+ TxD+/RxD+

Show 14 more labels / short text on this page
Serial Pinouts · Pinout 9-pin EIA-232 · EIA-422/485 Full Duplex · EIA-485 Half Duplex · 1 (in) DCD · 4 (out) DTR · 8 (in) CTS · 9 TxD- TxD-/RxD- · Pinout 9-pin EIA-232 · EIA-422/485 Full Duplex · EIA-485 Half Duplex · 1(in) DCD · 4 (out) DTR · 8 (in) CTS
Page 191 of the Perle Systems TS2 user manual — 5 (RTS) 5 (CTS)
Page 191 · click to enlarge
Page 191

EIA-232 Cabling Diagrams

This section shows how to create EIA-232 cables that are compatible with the Device Server.

Terminal DB25 Connector

The following diagrams show how the null modem cable should be configured when connecting to a terminal DB25.

DB25 Male

IOLAN DS1 DB25 (DTE)

(DTE)

2 (TxD) 3 (RxD)

3 (RxD) 2 (TxD)

4 (RTS) 5 (CTS)

5 (CTS) 4 (RTS)

6 (DSR) 20 (DTR)

7 (GND) 7 (GND)

20 (DTR) 6 (DSR)

DB25 Female

IOLAN DS1 DB25 (DCE)

(DTE)

3 (TxD) 3 (RxD)

2 (RxD) 2 (TxD)

5 (RTS) 5 (CTS)

4 (CTS) 4 (RTS)

20 (DSR) 20 (DTR)

7 (GND) 7 (GND)

6 (DTR) 6 (DSR)

Pinouts and Cabling Diagrams 191

EIA-232 Cabling Diagrams · Terminal DB25 · Terminal DB25

Page 192 of the Perle Systems TS2 user manual — 7 (RTS) 5 (CTS)
Page 192 · click to enlarge
Page 192

RJ45

IOLAN RJ45

(DTE)

4 (DSR) 3 20 (DTR)

3 (RTS) 2 5 (CTS)

5 (TxD) 4 3 (RxD)

6 (RxD) 5 2 (TxD)

7 (GND) 6 7 (GND)

8 (CTS) 7 4 (RTS)

9 (DTR) 8 6 (DSR)

DB9 Male

IOLAN DS1

(DTE)

3 (TxD) 3 (RxD)

2 (RxD) 2 (TxD)

7 (RTS) 5 (CTS)

8 (CTS) 4 (RTS)

6 (DSR) 20 (DTR)

5 (GND) 7 (GND)

4 (DTR) 6 (DSR)

Show 5 more labels / short text on this page
EIA-232 Cabling Diagrams · Terminal DB25 · 10-pin 8-pin · Terminal DB25 · DB9 Male
Page 193 of the Perle Systems TS2 user manual — 7 (GND) 6 7 (GND)
Page 193 · click to enlarge
Page 193

Modem DB25 Connector

The following diagrams show how a standard straight through cable should be configured when connecting to a DB25 modem.

DB25 Male

IOLAN DS1 DB25 (DTE)

(DCE)

2 (TxD) 2 (RxD)

3 (RxD) 3 (TxD)

4 (RTS) 4 (CTS)

5 (CTS) 5 (RTS)

6 (DSR) 6 (DSR)

7 (GND) 7 (GND)

8 (DCD) 8 (DCD)

20 (DTR) 20 (DTR)

RJ45

IOLAN RJ45

(DCE)

2 (DCD) 1 8 (DCD)

3 (RTS) 2 4 (CTS)

4 (DSR) 3 6 (DSR)

5 (TxD) 4 2 (RxD)

6 (RxD) 5 3 (TxD)

7 (GND) 6 7 (GND)

8 (CTS) 7 5 (RTS)

9 (DTR) 8 20 (DTR)

Pinouts and Cabling Diagrams 193

Show 4 more labels / short text on this page
EIA-232 Cabling Diagrams · Modem DB25 · Modem DB25 · 10-pin 8-pin
Page 194 of the Perle Systems TS2 user manual — 4 (DTR) 20 (DTR)
Page 194 · click to enlarge
Page 194

DB9 Male

IOLAN DS1

(DCE)

1 (DCD) 8 (DCD)

2 (RxD) 3 (TxD)

3 (TxD) 2 (RxD)

4 (DTR) 20 (DTR)

5 (GND) 7 (GND)

6 (DSR) 6 (DSR)

7 (RTS) 4 (CTS)

8 (CTS) 5 (RTS)

EIA-232 Cabling Diagrams · Modem DB25 · DB9 Male

Page 195 of the Perle Systems TS2 user manual — J9
Page 195 · click to enlarge
Page 195

Setting Jumpers Appendix C C

Introduction

The IOLAN contains jumpers that you might need to set before you configure it and put it into production. You can set the IOLAN line termination to on or off (this is off by default) if you are using EIA-422/485 (not applicable for I/O models).

1-Port IOLAN

IOLAN DB25 Male/Female To change the settings, do the following:

1. Unplug the IOLAN from the electrical outlet and disconnect everything from the box.
2. Open the case by unscrewing the two side screws, one on each side, and lifting off the top of the case. You should see the following:

Power Dip Switch Reset

J9

J1

RJ45

3. To turn line termination on , locate and jumper both J1 and J9.
4. Close the IOLAN case by replacing the case lid and the two screws. You can now power it on with the new settings.

Screw · Serial Connection · Screw

Page 196 of the Perle Systems TS2 user manual — J1 J9
Page 196 · click to enlarge
Page 196

IOLAN RJ45 To change the settings, do the following:

1. Unplug the IOLAN from the electrical outlet and disconnect everything from the box.
2. Open the case by unscrewing the two side screws, one on each side, and lifting off the top of the case. You should see the following:

Power Dip Switch Reset

RJ45

J1

J9

3. To turn line termination on , locate and jumper both J1 and J9.
4. Close the IOLAN case by replacing the case lid and the two screws. You can now power it on with the new settings.

IOLAN DB9 To change the settings, do the following:

1. Unplug the IOLAN from the electrical outlet and disconnect everything from the box.
2. Open the case by unscrewing the two side screws, one on each side, and lifting off the top of the case. You should see the following:

Power Dip Switch Reset

J1 J9

RJ45

3. To turn line termination on , locate and jumper both J1 and J9.
4. Close the IOLAN case by replacing the case lid and the two screws. You can now power it on with the new settings.
Show 7 more labels / short text on this page
Introduction · Screw · RJ45 Serial · Screw · Screw · DB9 Serial · Screw
Page 197 of the Perle Systems TS2 user manual — J8 J11
Page 197 · click to enlarge
Page 197

2-Port IOLAN

To change the settings, do the following:

1. Unplug the IOLAN from the electrical outlet and disconnect everything from the box.
2. Open the case by unscrewing the two side screws, one on each side, and lifting off the top of the case. You should see the following:

J7 1 2

Power DIP Switch Reset

J8 J11

J9

RJ45

RJ45

3. To turn line termination on for Line 1, locate and jumper both J7 and J8 (as shown in the diagram). To turn line termination on for Line 2, locate and jumper both J11 and J9.
4. Close the IOLAN case by replacing the case lid and the two screws. You can now power it on with the new settings.
Show 5 more labels / short text on this page
Introduction · Screw · RJ45 Pin1 · Screw · Setting Jumpers 197
Page 198 of the Perle Systems TS2 user manual — J5
Page 198 · click to enlarge
Page 198

Digital I/O Module

IOLANs that have Digital I/O have an input/output jumper that must be set for each channel and must match the software configuration for each channel. Depending on the model, the placement of the digital I/O board can change, so the diagram below shows how to set jumper for any digital board.To change the settings, do the following:

1. Detach the IOLAN from the electrical power source and disconnect everything from the box.
2. Open the case by unscrewing the five side screws, two on each side plus the grounding screw, and lifting off the top of the case. You should see the following configuration for the digital I/O board:

J5

J3

I/O

3. To configure either Channel 1 or Channel 3 (depending on how many Digital channels your I/O supports and following the mylar channel definitions) for Input, jumper J3 pin 1 and 2 (as shown); this is the default setting. To configure either Channel 2 or Channel 4 (depending on how many Digital channels your I/O supports and following the mylar channel definitions) for Output, jumper J5 pin 2 and 3 (as shown).
4. Close the IOLAN case by replacing the case lid and the five screws. You can now power it on with the new settings.
Show 5 more labels / short text on this page
Introduction · Channel 2/4 · Pin1 · Pin1 · Channel 1/3
Page 199 of the Perle Systems TS2 user manual — JP1 JP2
Page 199 · click to enlarge
Page 199

Analog Input Module

IOLANs that have Analog Input have a voltage/current jumper that must be set for each channel and must match the software configuration for each channel. To change the settings, do the following:

1. Detach the IOLAN from the electrical power source and disconnect everything from the box.
2. Open the case by unscrewing the five side screws, two on each side plus the grounding screw, and lifting off the top of the case. You should see the following configuration for the analog input board:

Channel 3 Channel 4

JP1 JP2

I/O

JP3 JP4

I/O

3. To configure Channel 1 for Voltage, no jumper should be set (as shown); this is the default setting. To configure Channel 2 for Current, jumper both J2 pins (as shown).
4. Close the IOLAN case by replacing the case lid and the five screws. You can now power it on with the new settings.
Show 4 more labels / short text on this page
Introduction · Channel 2 · Channel 1 · Setting Jumpers 199
Page 200 of the Perle Systems TS2 user manual — Analog Input Module
Page 200 · click to enlarge
Page 200

Introduction

Page 201 of the Perle Systems TS2 user manual — GND
Page 201 · click to enlarge
Page 201

I/O Wiring Diagrams Appendix D D

Wiring I/O Diagrams

This section describes how to wire the various IOLAN I/O models.

Digital I/O

Make sure the Digital I/O jumpers support the software setting; see Digital I/O Module on page 198 for jumper settings.

Digital Input Wet Contact If you are using a wet contact for your Digital input, for channel D1 connect one wire to D1 and the other wire to GND. The power source is supplied by the GND (ground) connector.

COM

GND

D1

D2

Digital Input Dry Contact If you are using a dry contact for your Digital input, for channel D1 connect one wire to D1 and the other wire to COM. The power source is supplied by the COM (common) connector.

GND

COM

D1

D2

Power Source · Power Source

Page 202 of the Perle Systems TS2 user manual — GND
Page 202 · click to enlarge
Page 202

Digital Output Sink For a Digital output sink (ground) configuration for channel D1, follow the diagram below.

COM

GND

D1

D2

Digital Output Source For a Digital output source (voltage) configuration for channel D1, follow the diagram below.

GND

COM

D1

D2

Show 8 more labels / short text on this page
Wiring I/O Diagrams · Battery + · + · Device · + · Battery · + - - · Device
Page 203 of the Perle Systems TS2 user manual — A1+
Page 203 · click to enlarge
Page 203

Analog Input

Make sure the Analog jumpers support the software setting; see Analog Input Module on page 199 for jumper settings.

Current To connect channel A1 with a 2-wire shielded cable, connect the positive wire to A1+, the negative wire to A1-, and optionally the shield to GND.

A1+

A2+

A3+

A4+

GND

A1-

A2-

A3-

A4-

If you have the positive/negative wires reversed, the output will always read 0 (zero).

Voltage To connect to Channel A1 with a 2-wire shielded cable, connect the positive wire to A1+, the negative wire to A1-, and optionally the shield to GND.

A1+

A2+

GND

A1-

A2-

A3+

A3-

A4+

A4-

If you have the positive/negative wires reversed, the polarity of the voltage will be reversed.

Temperature Input

If you are using RTD sensors, a short detected status will be displayed if the wires are connected improperly. RTD or thermocouple sensors will display an open detection status when the circuit is broken.

Thermocouple To connect to Channel A1 with a 2-wire cable, connect the positive wire to A1+ and the negative wire to A1-; you will not be using the A1s connection.

A1+

A2+

A3+

A4+

A1-

A2-

A3-

A4-

I/O Wiring Diagrams 203

Show 8 more labels / short text on this page
Wiring I/O Diagrams · + - shield · + - shield · A1s · A2s · A3s · A4s · + -
Page 204 of the Perle Systems TS2 user manual — COM
Page 204 · click to enlarge
Page 204

RTD 2-Wire In a 2-wire RTD configuration, connect the excite wire to A1-, the return wire to A1+, and jumper the sense wire from A1s with a insulated wire going to A1+.

A1+

A2+

A3+

A4+

A1-

A2-

A3-

A4-

RTD 3-Wire In a 3-wire RTD configuration, connect the return wire to A1+, the excite wire to A1-, and the sense wire to A1s.

A1+

A2+

A3+

A3-

A4+

A4-

A1-

A2-

RTD 4-Wire In a 4-wire RTD configuration, connect the return wire to A1+, the excite wire to A1-, the sense wire to A1s, and leave the fourth wire disconnected.

A1+

A1-

A2+

A2-

A3+

A3-

A4+

A4-

Relay Output

Normally Open Contact To connect Relay channel R1 for a circuit that is normally inactive, connect one wire to the COM (common) connector and one wire to the NO (normally open) connector.

COM

COM

NC

NO

NC

NO

R1

R2

Show 22 more labels / short text on this page
Wiring I/O Diagrams · A3s · A4s · A1s · A2s · sense · return · excite · A1s · A2s · A3s · A4s · return · excite · sense · A1s · A2s · A3s · A4s · return · excite · sense
Page 205 of the Perle Systems TS2 user manual — COM
Page 205 · click to enlarge
Page 205

Normally Closed Contact To connect relay channel R1 for a circuit that is normally active, connect one wire to the COM (common) connector and one wire to the NC (normally closed) connector.

COM

COM

NC

NO

NC R2

NO

R1

I/O Wiring Diagrams 205

Wiring I/O Diagrams

Page 206 of the Perle Systems TS2 user manual — Relay Output
Page 206 · click to enlarge
Page 206

Wiring I/O Diagrams

Page 207 of the Perle Systems TS2 user manual — PC
Page 207 · click to enlarge
Page 207

TruePort Utility Appendix E E

Introduction

This chapter provides information on the TruePort utility.

TruePort

TruePort is a com port redirector utility for the IOLAN. It can be run in two modes:

z TruePort Full mode—This mode allows complete device control and operates exactly like a directly connected serial port. It provides a complete COM port interface between the attached serial device and the network.

z TruePort Lite mode—This mode provides a simple raw data interface between the device and the network. Although the port will still operate as a COM port, control signals are ignored. In this mode, the serial communications parameters must be configured on the IOLAN.

You use TruePort when you want to connect extra terminals to a server using the IOLAN rather than a multi-port serial card. When run on UNIX, TruePort allows you to print directly from a terminal to an attached printer (transparent printing). You can also remap the slow baud rate of your UNIX server to a faster baud rate, as shown below.

Perle Systems TS2 — TruePort diagram (page 207)
Fig. 129 · TruePort
Perle Systems TS2 — TruePort diagram (page 207)
Fig. 130 · TruePort

Map UNIX baud rate 4,800 to 230,400 for faster throughput

Ethernet UNIX, running TruePort Daemon, baud rate 4,800

PC

Currently, TruePort is supported on Linux, Windows, SCO, Solaris, and others. For a complete list of of supported operating systems, see the Perle website.

For more information, see the TruePort User Guide or the TruePort Installation and Configuration Guide for Windows NT on the CD-ROM.

Network Serial Connection · perle

Page 208 of the Perle Systems TS2 user manual — API Response Format
Page 208 · click to enlarge
Page 208

API I/O Access Over TruePort

API I/O Access Over TruePort

You can access IOLAN I/O data through TruePort using the Perle API. The API uses the command/response format. See the ioapiotp.c sample program, found on the product CD-ROM, for an example implementation.

API Request Format

All data in the Request must be sent as a single write to the COM port. The API command takes the following format:

Number of Bytes Value

1 Function Code (in hex):

z 01—Get read/write boolean register

z 03—Get read/write register

z 04—Get read only register

z 15—Set read/write boolean register (0x0F)

z 16—Set read/write register (0x10)

2 Starting register number (see A4/T4 Registers on page 155, A4D2/A4R2 Registers on page 156, or D4/D2R2 Registers on page 157 for this value).

2 Number of registers to act on starting from the register defined in byte 2 above.

n Data for write. Some values must be read/written as a unit consisting of 2 consecutive registers. If the request is to write, the data to write follows the number of registers. If accessing registers consisting of 2 bytes or 4 bytes, the data is in big endian (network order) format.

API Response Format

The API command takes the following response format:

Number of Bytes Value

1 Function code of request if no error. Most significant bit will be set if an error occurred.

1 Length of data in response if no error occurred. If an error occurred, the byte will contain the error code (see the Error Codes table below).

n Data response for request (the number of bytes is dependent on the number and type of registers requested). If the request returns 2 or 4 byte values, it will be in big endian (network order) format. If the request returns boolean values, the least significant bit (bit 0) represents the first value requested and bits 1 to 7 represents subsequent boolean values. If more than 8 boolean registers are requested, they are returned in successive bytes.

Page 209 of the Perle Systems TS2 user manual — Error Codes
Page 209 · click to enlarge
Page 209

API I/O Access Over TruePort

Error Codes

01 Illegal Function The function code received in the query is not an allowable action for the server (or slave).

02 Illegal Data Address

The data address received in the query is not an allowable address for the server (or slave).

03 Illegal Data Value A value contained in the query data field is not an allowable value for server (or slave).

04 Slave Device Failure

An unrecoverable error occurred while the server (or slave) was attempting to perform the requested action.

Code Name Description · TruePort Utility 209

Page 210 of the Perle Systems TS2 user manual — API I/O Access Over TruePort
Page 210 · click to enlarge
Page 210

API I/O Access Over TruePort

Page 211 of the Perle Systems TS2 user manual — Starter Kit (Adapters/Cable)
Page 211 · click to enlarge
Page 211

Accessories Appendix F F

Introduction

This chapter provides information about peripheral IOLAN options that can be ordered separately from the product. Contact your sales representative to find out how to order the products listed in this appendix.

Starter Kit (Adapters/Cable)

The IOLAN Starter Kit includes the following:

z RJ45F to DB25M DTE Crossover Adapter

z RJ45F to DB25M DCE Modem Adapter

z RJ45F to DB25F DTE Crossover Adapter

z RJ45F to DB9M DTE Crossover Adapter

z RJ45F to DB9F DTE Crossover Adapter

z Sun/Cisco RJ45M Connector Cable for Rack Mount Models

The adapters/cable can be purchased as a kit or individually.

Page 212 of the Perle Systems TS2 user manual — (GND) 6 7 (GND)
Page 212 · click to enlarge
Page 212

RJ45F to DB25M DTE Crossover Adapter

The following diagram shows the IOLAN RJ45F-->DB25M DTE crossover adapter pinouts. This is model number DBA0011.

Perle Systems TS2 — RJ45F to DB25M DTE Crossover Adapter diagram (page 212)
Fig. 131 · RJ45F to DB25M DTE Crossover Adapter
Perle Systems TS2 — RJ45F to DB25M DTE Crossover Adapter diagram (page 212)
Fig. 132 · RJ45F to DB25M DTE Crossover Adapter

RJ45F DB25M DTE

(TxD) 4 3 (RxD)

(RxD) 5 2 (TxD)

(GND) 6 7 (GND)

(DTR) 8 6 (DSR) 8 (DCD)

(DSR) 3 20 (DTR)

(RTS) 2 5 (CTS)

(CTS) 7 4 (RTS)

Starter Kit (Adapters/Cable)

Page 213 of the Perle Systems TS2 user manual — (GND) 6 7 (GND)
Page 213 · click to enlarge
Page 213

RJ45F to DB25M DCE Modem Adapter

The following diagram shows the IOLAN RJ45FJDB25M DCE modem adapter pinouts. This is model number DBA0013.

RJ45F DB25M

(TxD) 4 3 (RxD)

(RxD) 5 2 (TxD)

(GND) 6 7 (GND)

(DTR) 8 20 (DTR)

(DSR) 3 6 (DSR)

(DCD) 1 8 (DCD)

(RTS) 2 4 (RTS)

(CTS) 7 5 (CTS)

Starter Kit (Adapters/Cable) · Accessories 213

Page 214 of the Perle Systems TS2 user manual — (GND) 6 7 (GND)
Page 214 · click to enlarge
Page 214

RJ45F to DB25F DTE Crossover Adapter

The following diagram shows the IOLAN RJ45JDB25F DTE crossover adapter pinouts. This is model number DBA0010.

Perle Systems TS2 — RJ45F to DB25F DTE Crossover Adapter diagram (page 214)
Fig. 133 · RJ45F to DB25F DTE Crossover Adapter

RJ45F DB25F

(TxD) 4 3 (RxD)

(RxD) 5 2 (TxD)

(GND) 6 7 (GND)

(DTR) 8 6 (DSR) 8 (DCD)

(DSR) 3 20 (DTR)

(RTS) 2 5 (CTS)

(CTS) 7 4 (RTS)

Starter Kit (Adapters/Cable)

Page 215 of the Perle Systems TS2 user manual — (GND) 6 5 (GND)
Page 215 · click to enlarge
Page 215

RJ45F to DB9M DTE Crossover Adapter

The following diagram shows the IOLAN RJ45JDB9M crossover adapter pinouts. This is model number DBA0021.

Perle Systems TS2 — RJ45F to DB9M DTE Crossover Adapter diagram (page 215)
Fig. 134 · RJ45F to DB9M DTE Crossover Adapter

RJ45F DB9M

(TxD) 4 2 (RxD)

(RxD) 5 3 (TxD)

(GND) 6 5 (GND)

(DTR) 8 1 (DCD) 6 (DSR)

(DSR) 3 4 (DTR)

(RTS) 2 8 (CTS)

(CTS) 7 7 (RTS)

Starter Kit (Adapters/Cable) · Accessories 215

Page 216 of the Perle Systems TS2 user manual — (GND) 6 4 (GND)
Page 216 · click to enlarge
Page 216

RJ45F to DB9F DTE Crossover Adapter

The following diagram shows the IOLAN RJ45FJDB9F crossover adapter pinouts. This is model number DBA0020.

Perle Systems TS2 — RJ45F to DB9F DTE Crossover Adapter diagram (page 216)
Fig. 135 · RJ45F to DB9F DTE Crossover Adapter

RJ45F DB9F

(TxD) 4 2 (RxD)

(RxD) 5 3 (TxD)

(GND) 6 5 (GND)

(DTR) 8 1 (DCD) 6 (DSR)

(DSR) 3 4 (DTR)

(RTS) 2 8 (CTS)

(CTS) 7 7 (RTS)

Sun/Cisco RJ45M Connector Cable for Rack Mount Models

This is a 3 meter RJ45MJRJ45M 8-wire Sun/Cisco modular cable. The following diagram shows how the IOLAN RJ45M cable is configured when connecting to the supplied Sun/Cisco RJ45 cable. This model number is CAB0030.

IOLAN RJ45M

RJ45M

(RTS) 2 8 (CTS)

(DSR) 3 2 (DTR)

(TxD) 4 6 (RxD)

(RxD) 5 3 (TxD)

(GND) 6 4 (GND)

(CTS) 7 1 (RTS)

(DTR) 8 7 (DSR)

Starter Kit (Adapters/Cable) · Sun/Cisco

Page 217 of the Perle Systems TS2 user manual — Communication Issues
Page 217 · click to enlarge
Page 217

Troubleshooting Appendix G G

Introduction

This chapter provides information that can help resolve problems with the IOLAN.

Hardware Problems

If the IOLAN Power/Ready LED is red and stays red for over 10 seconds, you have a hardware problem that might to require factory service. First, try the following:

z If the IOLAN is not in Console mode, do the following:

a. Set up a direct connection to the IOLAN; see Through the Serial Port on page 38 for information on this type of connection.

b. Power the IOLAN off.

c. Switch the Console dip switch to On.

d. Power the IOLAN on.

If there is a problem with the IOLAN firmware, you will need to reload the firmware, which can be found either on the CD-ROM that came with the IOLAN or on the Perle website, www.perle.com/downloads/serial.shtml.

z If the IOLAN is already in Console mode and the Power LED stays red, you need to make arrangements to return the IOLAN.

If you purchased the IOLAN less than 30 days before this problem appears, contact your distributor; otherwise, see the Perle web site (www.Perle.com) for factory service information. Note: no factory service can be performed on IOLANs that have not been registered.

Power/Ready LED continues to flash green in Desktop models

This is not an error, the Power/Ready LED will flahs green when serial port 1 is in Console Mode.

Communication Issues

General communication checks and practices are as follows:

z Are your cables connected and correctly configured? If you are using EIA-232, see EIA-232 Cabling Diagrams on page 191 to verify that your cables are correctly configured.

z Ping your host? If you can ping but packet loss is reported, ping another host/device on the same network. This will tell you whether the problem is specific to the host/device or general to the network.

z After entering or changing IP information for your IOLAN, reboot the IOLAN (does not apply when using BOOTP or DHCP). Once the IOLAN has rebooted, other network devices should be able to communicate with it (ping, telnet, etc.). Also, protocols such as ARP and proxy-ARP will work properly.

z Use the show routes command (command line only) or view the Routes statistics. Is there a route to the host?

Page 218 of the Perle Systems TS2 user manual — Login Problems
Page 218 · click to enlarge
Page 218

z If the WebManager or DeviceManager cannot communicate with the IOLAN, verify that the Security, Services HTTP parameter is enabled for WebManager and DeviceManagerD is enabled for DeviceManager.

DeviceManager Problems

Error Message: 16 bit Windows Subsystem - C:\WINDOWS\SYSTEM32\AUTOEXEC.NT. The system file is not suitable for running MS-DOS and Microsoft Windows applications. Choose 'Close' to terminate the application.

The error message can be misleading, because it is displayed even if the AUTOEXEC.NT file is actually missing.

To verify whether you have the file, type %windir%/system32/ in the address bar of an Explorer window. If there is no AUTOEXEC.NT file proceed as follows:

1. Browse to %windir%/repair/ (usually C:\WINDOWS\repair ).
2. Right-click and Copy the AUTOEXEC.NT file.
3. Browse to %windir%/system32/ (usually C:\WINDOWS\System32 ).
4. Right-click inside the window and Paste the file.

The error condition described here may also be the result of corruption of the AUTOEXEC.NT file, in which case the above procedure may be helpful to restore a valid file.

If the above procedure does not fix the DeviceManager installation problem, see http://support.microsoft.com/?kbid=324767 for the official Microsoft explanation.

Host Problems

Cannot access a host on a local network, verify:

z The network address is correct.

z The subnet mask is set correctly and reflects the network configuration.

z The broadcast address is set correctly and reflects the network configuration.

Cannot access a host on a remote network:

z Use the show route command to verify that there is a route to the remote host. If no gateway is specified, verify that a default gateway is specified. Ping the default gateway to check if it is working.

z Consider the situation beyond the gateway; for example, are intermediate gateways and the remote host available? Also, check the messages returned by the ping command; for example, that a particular host or gateway is unreachable.

Gateways added into the gateway table are ignored by the IOLAN:

z Have you used BOOTP and entered a single static gateway in the bootptab file entry? If yes, the other gateways will be ignored.

Access to host lost after a few minutes.

z If the route to this host goes through routers, make sure those routers are all sending RIP packets across the networks.

Login Problems

You have lost or don't know your password (as Admin user).

z You must reset the IOLAN to its factory default settings using the Reset switch on the rear panel. There is no procedure to access the IOLAN without a password.

DeviceManager Problems

Page 219 of the Perle Systems TS2 user manual — Unknown IP Address
Page 219 · click to enlarge
Page 219

Problems with Terminals

The following section concerns problems with the appearance of data on your terminal screen.

The IOLAN logs me out after a few minutes:

z Check the Idle Timer value set for the user. The default setting for the Idle Timer for all users is 0 seconds (does not timeout).

Corrupt data.

z Check your line settings (baud rate, stop bits, etc.)

Missing data.

z Verify that the same type of flow control is set in both your terminal and on the IOLAN’s port.

Error message not permitted on a dumb terminal after typing the CLI command screen.

z Set your Line to Termtype VT100, ANSI or WYSE60 (or other form of terminal emulation, if you have downloaded one). The default line type in the IOLAN is Dumb, which does not support the graphics characters necessary to view the text-based menus.

Screen corruption when using the text-based menu system.

z Verify that the terminal setup in the IOLAN matches your terminal.

z Verify that entries in the term file match your terminal setup.

z If using a PC/computer, verify that the type of terminal emulation selected in your application matches those supported by the IOLAN.

When using the function keys on your keyboard, nothing happens or your sessions keep swapping.

z Change your Hotkey Prefix character. The function keys on the keyboards of some terminals (like WYSE60) send character sequences which begin with ^a; unfortunately, ^a is also the default Hotkey Prefix, which you use to switch between sessions. A valid alternative would be ^b (hex=02). If you are the system administrator, you can change any user’s Hotkey Prefix character.

When using a downloaded terminal definition, you are having problems using arrow keys.

z Use Ctrl-K, Ctrl-J, Ctrl-H and Ctrl-L for up, down, left and right respectively.

When switching from a session back to the text menus, both screen images are superimposed.

z Press ^r to redraw the screen.

INITError in terminal file < filename >

z This error indicates that you have exceeded the 80 character limit for one or more of the terminal capabilities defined in the reported file.

INITError on line n in terminal file < filename >

z You have omitted the = sign from the reported line.

Unknown IP Address

You have already configured tje IOLAN and you do know your password, but have lost, misconfigured, or don't know the IP address of the IOLAN, and you cannot obtain a login.

z If the IOLAN resides within the local network segment, you can use DeviceManager to find the IOLAN.

z You can connect directly to the serial port of the IOLAN, as explained in Through the Serial Port on page 38.

Problems with Terminals

Page 220 of the Perle Systems TS2 user manual — I/O Models
Page 220 · click to enlarge
Page 220

DHCP/BOOTP Problems

Messages: host name too long or filename too long.

z The IOLAN can only accept host names of 14 characters or file names of 64 characters, so verify that you are not attempting to pass a string that is longer than those maximums.

DHCP or BOOTP have been set up to configure my IOLAN, but does not seem to have done anything.

z Check that the server DHCP/BOOTP service is set to on, if not set it to on and reboot.

z Check that your BOOTP server is configured for your IOLAN or that your DHCP server has an active lease pool (scope) with at least 1 free IP address.

You observe TFTP errors when the IOLAN boots, for example:

TFTP: File not found : filename TFTP: Timed out This has a number of causes, including:

z The file names you specified to DHCP/BOOTP do not exist or are in the wrong place.

z The server for any of the downloadable files in your bootfile has no TFTP server running.

z Verify that lease data in your DHCP server manager is correct.

z Reset or restart the DHCP server.

Language Problems

In a customised language, the text strings appear in the wrong place in the Menu, CLI, or WebManager.

z Check the original ASCII text file you used to translate to your customised language. The sequence of the line much match exactly (be aware that comments don’t affect line sequence, but can affect the actual line that the strings appear on). So, if you strip out all comments, if the original file says line 1000 should be string none, then line 1000 (stripped of comments) should be the translated version of none.

Long Reboot Cycle

Rebooting the IOLAN takes a long time.

If you are not using DHCP/BOOTP, disable this within the Server Services; otherwise, the IOLAN waits to timeout for a request to DHCP/BOOTP.

I/O Models

An I/O Digital or Relay controlled motor is starting/stopping

z Digital and Relay channels have automatically resetting fuses, meaning that if the circuit gets overloaded and the fuse blows, it will automatically reset when the circuit cools down.

An A4R2 model is starting/stopping

z The A4R2 model can run at 55 degrees Celsius ambient temperature when the input voltage is 22VDC or below. If the input voltage exceeds 22VDC, the maximum ambient temperature will drop into the range of 45-50 degrees Celsius to run successfully.

DHCP/BOOTP Problems

Page 221 of the Perle Systems TS2 user manual — Glossary
Page 221 · click to enlarge
Page 221

Glossary

This chapter provides definitions for Device Server terms.

An Internet protocol that enables a diskless workstation to discover its own IP address, the IP address of a BOOTP server on the network, and a file to be loaded into memory to boot the machine. This enables the workstation to boot without requiring a hard or floppy disk drive.

Callback A security feature where the Device Server calls back the User at a predetermined number defined in the User’s account.

CHAP (Challenge Handshake Authentication Protocol)

Standard authentication protocol for PPP connections. It provides a higher level of security than PAP and should be used whenever possible. see PAP

Community (SNMP) An SNMP community is the group that devices and management stations running SNMP belong to. It helps define where information is sent.

DHCP (Dynamic Host Configuration Protocol)

A TCP/IP protocol that provides static and dynamic address allocation and management.

Direct Connection Connections that bypass the Device Server enabling the user to log straight into a specific host. A direct connection is recommended where a user logging in to the Device Server is not required.

Ethernet A high-speed (10Mbps,100Mbps) cable technology that connects devices to a LAN, using one or more sets of communication protocols.

Fixed Callback A method where there is a specific number defined to callback a user.

Local Authentication Uses the user ID and password stored within the Device Server User database.

LPD Line Printer Daemon. A printer protocol that uses TCP/IP to establish connections between printers and workstations on a network. The technology was developed originally for BSD UNIX and has since become the de facto cross-platform printing protocol.

A series of commands sent to the modem by a communications program at start up. These commands tell a modem how to set itself up in order to communicate easily with another modem.

MOTD Message of the day. This is defined by a file whose contents display when users log into the Device Server.

Multicast The broadcasting of messages to a specified group of workstations on a LAN, WAN, or internet.

A communication control character sent by the receiving destination indicating that the last message was not received correctly.

BOOTP (BOOTstrap Protocol) · Modem Initialization String · NAK (Negative Acknowledgment)

Page 222 of the Perle Systems TS2 user manual — Glossary
Page 222 · click to enlarge
Page 222

PAP (Password Authentication Protocol)

Standard authentication protocol for PPP connections. see CHAP

RADIUS (Remote Authentication Dial In Users Services)

An open standard network security server that communicates with the PAP protocol.

Reverse Connection Connections that originate from a host that go directly to a serial device through the Device Server.

RIP (Routing Information Protocol)

A protocol that allows gateways and hosts to exchange information about various routes to different networks.

Roaming Callback A method where the client supplies the number for callback when they dial in.

RPC Remote Procedure Call. A type of protocol that allows a program on one computer to execute a program on a server computer.

Silent Connection Silent connections are the same as direct connections except that they are permanently established. The host login prompt is displayed on the screen. Logging out redisplays this prompt. Silent connections, unlike direct connections, however, make permanent use of pseudo tty resources and therefore consume host resources even when not in use.

SNMP (Simple Network Management Protocol)

A protocol for managing network devices.

Subnet/Prefix Bits Identifies the device’s IP address, which portion constitutes the network address and which portion constitutes the host address.

Page 224 of the Perle Systems TS2 user manual — Table of contents
Page 224 · click to enlarge
Page 224

Table of contents

DS1/TS2 User’s Guidep.1Table of Contentsp.3Prefacep.17About This Bookp.17Intended Audiencep.17Documentationp.17Typeface Conventionsp.18Online Helpp.18Introductionp.19About the IOLANp.19IOLAN Family Modelsp.19IOLAN Featuresp.20Hardwarep.20Softwarep.21Securityp.21Hardware and Connectivityp.23Introductionp.23IOLAN Componentsp.23What’s Includedp.23What You Need to Supplyp.23Available Accessoriesp.23Power Supply Specificationsp.24Desktop Modelsp.24Getting to Know Your IOLANp.24Overviewp.24DS1p.25TS2p.25I/Op.26Console/Serial Switchp.27Powering Up the IOLANp.28Serial Only Modelsp.28I/O Modelsp.28Configuration Methodsp.29Introductionp.29Configuration Methods Overviewp.30Configures an IP Addressp.30Requires a Configured IP Addressp.30Easy Config Wizardp.31DeviceManagerp.32Overviewp.32Access Platformsp.32Unique Featuresp.32Connecting to the IOLAN Using DeviceManagerp.32Using DeviceManagerp.34WebManagerp.35Overviewp.35Access Platformsp.35Unique Featuresp.35Connecting to the IOLAN Using WebManagerp.35Using WebManagerp.36Command Line Interfacep.37Overviewp.37Access Platformsp.37Unique Featuresp.37Connecting to the IOLAN Using the CLIp.37Using the CLIp.38Menup.38Overviewp.38Access Platformsp.38Unique Featuresp.38Connecting to the IOLAN Using the Menup.38Using the Menup.39DHCP/BOOTPp.40Overviewp.40Unique Featuresp.40Connecting to the IOLAN Using DHCP/BOOTPp.40Using DHCP/BOOTPp.40DHCP/BOOTP Parametersp.41SNMPp.42Overviewp.42Access Platformsp.42Unique Featuresp.42Connecting to the IOLAN Using SNMPp.42Using the SNMP MIBp.43Getting Startedp.45Introductionp.45Easy Configuration Wizardp.45Setting Up the Networkp.46Using DeviceManagerp.46Using WebManagerp.47Using ARP-Pingp.49For an IPv6 Networkp.49Setting Up the Serial Port(s)p.50Setting Up Usersp.52Using DeviceManager and WebManagerp.53Introductionp.53Navigating DeviceManager/WebManagerp.54DeviceManagerp.54WebManagerp.55Using DeviceManager to Connect to the IOLANp.56Starting a New Sessionp.56Assigning a Temporary IP Address to a New IOLANp.57Adding/Deleting Manual IOLANsp.58Logging in to the IOLANp.58Using WebManager to Connect to the IOLANp.59Logging into the IOLANp.59Configuration Filesp.59Creating a New IOLAN Configuration in DeviceManagerp.59Opening an Existing Configuration Filep.60Importing an Existing Configuration Filep.60Managing the IOLANp.60Network Settingsp.61Introductionp.61IP Settingsp.62IP Settingsp.62Advancedp.63Advancedp.64Host Tablep.64Adding/Editing a Hostp.65Route Listp.65Adding/Editing Routesp.66Configuring Serial Portsp.67Introductionp.67Serial Portsp.67Overviewp.67Functionalityp.67Serial Port Profilesp.70Common Tabsp.70Console Management Profilep.74TruePort Profilep.78TCP Sockets Profilep.83UDP Sockets Profilep.88Terminal Profilep.91User Service Settingsp.95Serial Tunneling Profilep.97Virtual Modem Profilep.99Control Signal I/O Profilep.103Modbus Gateway Profilep.106Custom Application Profilep.112Advancedp.113Advanced Serial Settings Tabp.113Modems Tabp.114TruePort Baud Rate Tabp.115Configuring Usersp.117Introductionp.117User Settingsp.118Overviewp.118Functionalityp.118Adding/Editing Usersp.119General Tabp.119Services Tabp.121Advanced Tabp.122Sessions Tabp.123Serial Port Access Tabp.125Configuring Securityp.127Introductionp.127Servicesp.127Overviewp.127Functionalityp.127Field Descriptionsp.128Configuring I/O Interfacesp.129Introductionp.129Settingsp.130Overviewp.130I/O Access Functionalityp.130Failsafe Timer Functionalityp.132UDP Functionalityp.133Temperature Functionalityp.134Channelsp.135Analogp.135Digital Inputp.137Digital Outputp.140Relayp.143Temperaturep.146Alarm Settingsp.148I/O UDPp.150UDP Unicast Formatp.150UDP Unicast Examplep.151I/O Modbus Slavep.152Modbus Serial Application Connected to the Serial Portp.152Modbus Serial Application Connected to the Networkp.152Modbus TCP Applicationp.153Modbus I/O Accessp.153Function Codesp.153I/O Coil/Register Descriptionsp.154Serial Port Coil/Register Descriptionsp.155A4/T4 Registersp.155A4D2/A4R2 Registersp.156D4/D2R2 Registersp.157Serial Pin Signalsp.157TruePort I/Op.158TruePort/Modbus Combinationp.158API Over TruePort Onlyp.159Accessing I/O Data Via TruePortp.160Introductionp.160Setupp.160Format of API Commandsp.161Get Commandsp.161Set Commandsp.162Error Codesp.164I/O SNMP Trapsp.164Configuring the Systemp.165Introductionp.165Alertsp.165Syslogp.165Managementp.166SNMPp.166Custom App/Pluginp.167Advancedp.168Controlling the I/O Channelsp.171Introductionp.171I/O Channelsp.171Overviewp.171System Administrationp.173Introductionp.173Managing Configuration Filesp.173Saving Configuration Filesp.173Downloading Configuration Filesp.173Downloading Configuration Files to Multiple IOLANsp.174Uploading Configuration Filesp.175Downloading IOLAN Firmwarep.175Calibrating I/Op.176Calibrating Analog Inputp.176Calibrating Temperature Inputp.176Calibrating Analog Channelsp.177Resetting Calibration Datap.178Setting the IOLAN’s Date and Timep.178Rebooting the IOLANp.178Resetting the IOLAN to Factory Defaultsp.179Language Supportp.179Loading a Supplied Languagep.179Translation Guidancep.180Software Upgrades and Language Filesp.180Downloading Terminal Definitionsp.181Creating Terminal Definition Filesp.181Resetting Configuration Parametersp.182Lost Admin Passwordp.183Virtual Modem AT Commandsp.185Virtual Modem Initialization Commandsp.185Pinouts and Cabling Diagramsp.187Serial Pinoutsp.187DB25 Malep.187DB25 Femalep.188RJ45p.189DB9 Male (Serial Only)p.190DB9 Male I/Op.190EIA-232 Cabling Diagramsp.191Terminal DB25 Connectorp.191Modem DB25 Connectorp.193Setting Jumpersp.195Introductionp.1951-Port IOLANp.1952-Port IOLANp.197Digital I/O Modulep.198Analog Input Modulep.199I/O Wiring Diagramsp.201Wiring I/O Diagramsp.201Digital I/Op.201Analog Inputp.203Temperature Inputp.203Relay Outputp.204TruePort Utilityp.207Introductionp.207TruePortp.207API I/O Access Over TruePortp.208API Request Formatp.208API Response Formatp.208Accessoriesp.211Introductionp.211Starter Kit (Adapters/Cable)p.211RJ45F to DB25M DTE Crossover Adapterp.212RJ45F to DB25M DCE Modem Adapterp.213RJ45F to DB25F DTE Crossover Adapterp.214RJ45F to DB9M DTE Crossover Adapterp.215RJ45F to DB9F DTE Crossover Adapterp.216Sun/Cisco RJ45M Connector Cable for Rack Mount Modelsp.216Troubleshootingp.217Introductionp.217Hardware Problemsp.217Communication Issuesp.217DeviceManager Problemsp.218Host Problemsp.218Login Problemsp.218Problems with Terminalsp.219Unknown IP Addressp.219DHCP/BOOTP Problemsp.220Language Problemsp.220Long Reboot Cyclep.220I/O Modelsp.220Glossaryp.221Indexp.223
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Perle Systems TS2

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Perle Systems TS2

Be the first to ask — other owners or our team will answer.

Original document

Perle Systems TS2 manual PDF

224 pages·4 MB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…