and SPEED LE Express
Serial Adapters
User Guide
Using this on-line manual. See page 5.
Fast Contents. See page 7.
Contents. See page 8.
Index. See page 60.

This document must not be reproduced in any way whatsoever, either printed or electronically, without the consent of:
Perle Systems Limited 60 Renfrew Drive Markham, Ontario, Canada L3R 0E1
Perle reserves the right to make changes without further notice, to any products to improve reliability, function or design.
JETSTREAM, JETSTREAM4000, JETSTREAM8500 and LANSTREAM2000 are trademarks of Perle Systems Limited.
Microsoft, Windows 2000, XP, Server 2003, Vista, Server 2008, and Internet Explorer are trademarks of Microsoft Corporation.
Netscape is a trademark of Netscape Communications Corporation.
Perle Systems Limited.
Copyright statement

The products described in this manual have been found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions in this Guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his/her own expense.
FCC Note

SPEED LE and SPEED LE Express Serial Adapters User Guide About this manual
This manual tells you how to install, configure and use the Perle SPEED LE and SPEED LE Express serial adaptor cards, cabling hardware, associated drivers and utilities. Who this manual is for
This manual is aimed at users who want to add extra serial ports to their system using SPEED LE or SPEED LE Express serial adaptor cards. This manual requires a working knowledge of using personal computers and associated operating systems, as well as experience in installing host cards.
Purpose of this manual SPEED LE User Guide

The following is a brief guide to using this manual on-line.
This manual features document navigation hypertext buttons in the header area as shown in the next picture;

Jump to Using this on-line manual
Jump to Quick Reference
Jump to previous location
Jump to front of current chapter
Jump to Fast contents
You can also navigate around this manual by clicking on any cross reference or text in blue for example, Hypertext jumps.
The Fast Contents, Contents and Index entries are all hypertext jumps into this manual.
Using this on-line manual SPEED LE User Guide
Jump to Index · (if included) · Jump to Contents




You need to read this chapter if you want to...
You need to read this chapter if you want an introduction to the SPEED LE or SPEED LE Express serial adaptor cards, driver software, and utilities.
This chapter provides introductory information about the Perle SPEED LE and SPEED LE Express serial adaptor cards, driver software, and configuration utilities.
This chapter includes the following sections;
Chapter 1 Introduction

The SPEED LE and SPEED LE Express Serial Adaptor cards are multi-port cards which provide extra serial ports for EIA-232, peripherals. These cards plug into your PC servers and provide 1, 2, 4, or 8 high speed ports suitable for remote access, data collection, point of sale, or any other EIA-232 applications.
You use the SPEED LE and SPEED LE Express serial adaptor cards when you want a robust entry level solution for the small office or point of sale applications. Typically you use SPEED LE and SPEED LE Express serial adaptor cards because you want to add extra serial ports to an existing computer system rather than replacing it with the considerable cost that entails. Higher data rates and ESD protection in the SPEED LE and SPEED LE Express serial adaptor cards make it suitable for any modem or ISDN TA application.
To use the SPEED LE and SPEED LE Express serial adaptor cards, you must first install the drivers supplied with the card and then configure each card as required prior to mechanical installation. The installation procedure varies for different operating systems. Please read Before You Start on page 15 in Chapter 2 Installing drivers and host cards before commencing installation.

Chapter 1 Introduction

The connector box or cable required for the SPEED LE products you are using depends on the number of ports and product type. For details see Chapter 3 Cabling Information.
Chapter 1 Introduction

You need to read this chapter if you want to...
You need to read this chapter if you want to install SPEED LE or SPEED LE Express serial adaptor cards, associated hardware, and software.
This chapter provides information about installing and configuring SPEED LE and SPEED LE Express serial adaptor cards.
The procedure for installing and configuring SPEED LE or SPEED LE Express serial adaptor cards varies for different operating systems. Please read Before You Start on page 15 before commencing installation.
This chapter includes the following sections;
Chapter 2 Installing Drivers and Host Cards

Before you install your SPEED LE or SPEED LE Express host cards and software, note that the procedure for installing and configuring SPEED LE or SPEED LE Express serial adaptor cards varies for different operating systems.
To install under a particular operating system, please refer to one of the operating system specific installation procedures listed below;
Chapter 2 Installing Drivers and Host Cards

You can install the SPEED LE or SPEED LE Express driver and utility software from the Perle website. To do this proceed as follows;
http://www.perle.com/downloads
In the event of any problems contact your System Administrator or Internet Service provider for assistance.
Chapter 2 Installing Drivers and Host Cards

This section describes how to install the SPEED LE or SPEED LE Express driver software under Microsoft Windows 2000, XP, Server 2003, Vista, or Server 2008.
This section includes the following;
The general procedure for installing SPEED LE or SPEED LE Express cards under the Windows 2000, XP, Server 2003, Vista, or Server 2008 operating systems is as follows;
Chapter 2 Installing Drivers and Host Cards

To install or enable the SPEED LE or SPEED LE Express device drivers on your system proceed as follows:
If you have installed any new SPEED LE or SPEED LE Express cards, a Found New Hardware message is shown, followed by the Found New Hardware wizard as shown.


pserial-x86V.zip for 32-bit Windows operating systems.
pserial-amd64V.zip for 64-bit Windows operating systems.
pserial-ia64V.zip for 64-bit Windows Itanium operating systems.
Chapter 2 Installing Drivers and Host Cards


Chapter 2 Installing Drivers and Host Cards


If you are installing an unsigned driver, you may have to click through the Found New Hardware wizard for every SPEED LE or SPEED LE Express port on your system.
Your SPEED LE or SPEED LE Express driver installation is now finished.
Whenever you add any additional SPEED LE or SPEED LE Express hardware to your system, Windows might install the latest digitally signed driver in its database (depending on your Windows operating system and settings). To ensure you have the latest driver installed after you add new hardware, you can either:
Chapter 2 Installing Drivers and Host Cards
or

To configure SPEED LE or SPEED LE Express serial ports under Windows 2000, XP, Server 2003, Vista, or Server 2008 proceed as follows:
The control panel window is now displayed.

The System Properties tabbed window is now displayed.
The hardware page is now displayed.
The Device Manager window is now displayed.

Chapter 2 Installing Drivers and Host Cards

The device Properties tabbed window is now displayed.

DSR Always On—This feature is used for systems where the wiring does not support the DSR signal but the Host application still requires that the DSR be active. When the DSR Always On option is enabled, the driver will always report to the application that the DSR signal is "on".
Chapter 2 Installing Drivers and Host Cards

This section tells you how to install host cards, software drivers, and utilities under the Linux operating system and includes the following:
The general procedure for installing and configuring host cards, driver software and associated utilities for the Linux operating system is as follows:
Your system can now use the SPEED LE serial adaptor cards you have installed.
SPEED LE or SPEED LE Express cards installed on Linux machines use the perle-serial driver for Linux. The driver supports the Linux kernel versions 2.4 and 2.6. The kernel header files are needed for kernel and 2.4. For the 2.6 kernel, a configuration kernel source tree and a set of makefile rules describing how the modules are built is required.
The driver is supplied in both source RPM package format and a compressed tar file. The procedure for installation of each format is described in the following sections.
Chapter 2 Installing Drivers and Host Cards

Install from Source RPM
The will change depending on the version of the RPM utilities installed. For newer versions (i.e. 4.2) , the is “rpmbuild”. For older versions use “rpm”.
rpm –ivh perle-serial-<version>-<release>.src.rpm
<rpm build command> -bb perle-serial-<version>.spec
cd /usr/src/<packages directory>/RPMS/<arch>
rpm –ivh perle-serial-<version>-<release>.<arch>.rpm
The value is the architecture of your LINUX machine such as “i386” or “alpha”.
Install from Tar File Driver Version 3.4.x or Below
tar –xzvf perle-serial-<version>-<release>.tgz
cd /tmp/perle-serial-<version>-<release>
./tar_install.sh
Chapter 2 Installing Drivers and Host Cards
cd /usr/src/<packages directory>/SPECS

Install from Tar File Driver Version 3.5.x or Higher
tar –xzvf perle-serial-<version>-<release>.tgz
After the SPEED LE or SPEED LE Express cards and the new driver have been installed, terminal devices will need to be created for the added ports. This can be done be using the ps_addports utility.
To use the ps_addports script, enter the following command:
where:
m is the first port device (starting at 0)
n is the last port device to add.
The port devices will be created in the /dev directory and will have the following format:
where nn is the 2 digit port number.
The perle-serial driver has been installed so that it will automatically be loaded the first time a SPEED LE or SPEED LE Express device is used. However, if more than one SPEED LE or SPEED LE Express card was installed in the Linux machine, then the driver can be manually loaded to determine which terminal device numbers have been assigned to each card.
To load the driver, enter the command:
Review the messages in the file /var/log/messages.
Once the port devices have been created, they may be used as standard LINUX serial TTYs.
Chapter 2 Installing Drivers and Host Cards
make · ps_addports m n · modprobe perle-serial

The setultrap utility can be used to configure the DSR Always On option. This feature is used for systems where the wiring does not support the DSR signal but the Host application still requires that the DSR be active. When the DSR Always On option to set to "on," the driver will always report to the application that the DSR signal is "on". The syntax for the command is:
To use the setultrap utility, enter the following command:
setultrap -f device name -r on|off|list
where:
-f specifies the port the action should be taken on.
-r sets DSRAlwaysOn option on or off for serial devices(s). Use list to see the existing configuration. By default this option is set to off.
To uninstall the driver (RPM), enter the following command:
To uninstall the driver (TAR) version 3.5.x or higher, enter the following command:
To uninstall the driver (TAR) version 3.4.x or lower, enter the following command:
./tar_uninstall.sh
Chapter 2 Installing Drivers and Host Cards
rpm -e perle-serial · make uninstall

This section describes the mechanical installation of the SPEED LE and SPEED LE Express host cards and associated connector boxes and cables for 1,2, 4, and 8 ports and includes the following;
This section describes the mechanical installation of SPEED LE and SPEED LE Express cards.
To install a SPEED LE or SPEED LE Express host card proceed as follows;
The exact location of host card slots varies for different systems, for exact mechanical details of your system, refer to your system documentation.
Chapter 2 Installing Drivers and Host Cards


Full anti-static precautions should be taken when handling host cards.

Installation of SPEED LE or SPEED LE Express cards is now complete.
This section describes the mechanical installation of cables and connector boxes to the SPEED LE and SPEED LE Express host cards for 1, 2, 4, and 8 ports and includes the following;
For information on available connectors and their pinouts and cabling, see Chapter 3 Cabling Information.
Installing cables on SPEED1 LE, SPEED2 LE, and SPEED4 LE cards
The SPEED1 LE has a D89M connector on the back panel.
The SPEED2 LE and SPEED4 LE each have RJ45 connectors on the back panel. There is one for each serial port and they are labelled 1 to 4.
Chapter 2 Installing Drivers and Host Cards

Installing Fan-out Cables and Connector Boxes on SPEED4 LE HD and SPEED8 LE HD Cards
SPEED4 LE HD and SPEED8 LE HD cards have a single VHDCI-68 connector on the back panel. It provides the signals for 4 or 8 serial ports.
A fan-out cable or connector box with the proper individual connectors can be plugged into the card to provide the desired interface. The port numbers will be identified on the interface connectors or connector box.
The SPEED LE fan-out cables and connector box cable need to be secured or supported in case of sudden contact or excessive weight on the cables. Please ensure that adequate caution is taken to avoid possible damage to the SPEED LE card or Host system. This can be accomplished by securing the cable(s) to a rack or to the back of the server as shown below:

Chapter 2 Installing Drivers and Host Cards


To remove any SPEED LE or SPEED LE Express card from your system, proceed as follows;

The exact location of host card slots varies for different systems, for exact mechanical details of your system, refer to your system documentation.
Full anti-static precautions should be taken when handling host cards.

Removal of SPEED LE or SPEED LE Express card is now complete.
Chapter 2 Installing Drivers and Host Cards

You need to read this chapter if you want to...
You need to read this chapter if you want cabling information for the SPEED LE and SPEED LE Express serial adaptor cards.
This chapter provides cabling and connector pinout information for the SPEED LE and SPEED LE Express serial adaptor cards. Included are details of standard cables for use with SPEED LE and SPEED LE Express products available from Perle.
This chapter includes the following sections:

RI In Ring Indicator
DCD In Data Carrier Detect
RTS Out Request To Send
DSR In Data Set Ready
TXD Out Transmit Data
RXD In Receive Data
CTS In Clear to Send
DTR Out Data Terminal Ready
Definitions of Signals and Direction
EIA-232 Direction Description · S-GND Signal Ground · C-GND Chassis Ground

The following diagram shows the SPEED1 LE and SPEED LE Express standard and Low Profile back panels respectively.

2 RXD
3 TXD
4 DTR
5 S-GND
6 DSR
7 RTS
8 CTS
9 RI
10 C-GND
Definitions of Signals and Direction
DB9M pin EIA-232


The following diagram shows the SPEED2 LE and SPEED4 LE RJ-45 cards back panel.

The RJ45 connector has a 10-pin configuration. If you require an 8-pin connector configuration, use the pinouts in the RJ45 8-pin column. The connector pinout for each RJ45 socket fitted to the SPEED LE cards is as follows;
RJ45 10-pin EIA-232 DIRECTION RJ45 8-pin
2 DCD IN 1
3 DTR OUT 2
4 DSR IN 3
5 GND 4
6 TXD OUT 5
7 RXD IN 6
8 RTS OUT 7
9 CTS IN 8
10 N/A
Host Card Back Panel Connectors and Pinouts
Shell C-GND Shell

The following diagram shows the SPEED2 LE Express and SPEED4 LE Express RJ-45 cards back panel.
The RJ45 connector has a 10-pin configuration. If you require an 8-pin connector configuration, use the pinouts in the RJ45 8-pin column. The connector pinout for each RJ45 socket fitted to the SPEED LE Express cards is as follows;
RJ45 10-pin EIA-232 RJ45 8-pin
2 DCD 1
3 RTS 2
4 DSR 3
5 TXD 4
6 RXD 5
7 S-GND 6
8 CTS 7
9 DTR 8
10 N/A
Host Card Back Panel Connectors and Pinouts
Shell C-GND Shell


The SPEED LE and SPEED LE Express parallel port pinouts are provided below for cards that support the parallel port.

1 1 out -Strobe Set Low p1ulse >0.5 us to send
2 2 out Data 0 Set to least significant data
9 9 out Data 7 Set to most significant data
10 10 in -Ack IRQ; Low Pulse ~ 5 uS, after accept
12 12 in +PaperEnd High for out of paper
14 14 out -AutoFd Set Low to autofeed one line
16 31 out -Init Set Low pulse > 50uS to init
17 36 out -Select Set Low to select printer
18-25 19-30, 33,17,16 Ground Do not connect any of these grounds to a shield
Host Card Back Panel Connectors and Pinouts

The following diagram shows the SPEED4 LE HD Low Profile and standard back panels respectively.

The connector pinout for each VHDCI-68 Ultra SCSI connector fitted to the SPEED4 LE HD Low Profile are as follows:
VHDCI-68 Ultra SCSI Pin Number EIA-232
2 CTS4
3 RI4
4 RTS4
5 DCD4
6 DTR4
7 DSR4
8 TXD4
Host Card Back Panel Connectors and Pinouts

VHDCI-68 Ultra SCSI Pin Number EIA-232
10 TXD3
11 DSR3
12 DTR3
13 DCD3
14 RTS3
15 RI3
16 CTS3
17 RXD3
18 RXD2
19 CTS2
20 RI2
21 RTS2
22 DCD2
23 DTR2
24 DSR2
25 TXD2
26 S-GND
27 TXD1
28 DSR1
29 DTR1
30 DCD1
31 RTS1
32 RI1
33 CTS1
34 RXD1
35-42 NC
43 S-GND
44-59 NC
60 S-GND
61-68 NC
Host Card Back Panel Connectors and Pinouts

The following diagram shows the SPEED8 LE HD standard and Low profile back panels respectively

The connector pinout for each VHDCI-68 Ultra SCSI connector fitted to the SPEED8 LE HD, Low profile are as follows;
Ports 1-8 of VHDCI-68 Connector for SPEED8 LE HD adapter cards
VHDCI-68 Ultra SCSI Pin Number EIA-232
2 CTS7
3 RI7
4 RTS7
5 DCD7
6 DTR7
7 DSR7
8 TXD7
9 S-GND
10 TXD5
11 DSR5
12 DTR5
Host Card Back Panel Connectors and Pinouts

VHDCI-68 Ultra SCSI Pin Number EIA-232
14 RTS5
15 RI5
16 CTS5
17 RXD5
18 RXD3
19 CTS3
20 RI3
21 RTS3
22 DCD3
23 DTR3
24 DSR3
25 TXD3
26 S-GND
27 TXD1
28 DSR1
29 DTR1
30 DCD1
31 RTS1
32 RI1
33 CTS1
34 RXD1
35 RXD8
36 CTS8
37 RI8
38 RTS8
39 DCD8
40 DTR8
41 DSR8
42 TXD8
43 S-GND
Host Card Back Panel Connectors and Pinouts

VHDCI-68 Ultra SCSI Pin Number EIA-232
45 DSR6
46 DTR6
47 DCD6
48 RTS6
49 RI6
50 CTS6
51 RXD6
52 RXD4
53 CTS4
54 RI4
55 RTS4
56 DCD4
57 DTR4
58 DSR4
59 TXD4
60 S-GND
61 TXD2
62 DSR2
63 DTR2
64 DCD2
65 RTS2
66 RI2
67 CTS2
68 RXD2
Host Card Back Panel Connectors and Pinouts

The connector pinout information for the SPEED LE product you are using depends on the number of ports and type of connector box or cable used as detailed in the next table;
Cable or connector box options
For connector pinouts see...
SPEED LE RJ45 10-pin RJ45 - DB25M Converter See page 45
RJ45 - DB9M Converter See page 46
VHDCI-68 RJ45 Connector Box See page 47
DB25M Connector Box See page 48
DB9M Connector Box See page 49
DB25M Fan-out Cable See page 50
DB9M Fan-out Cable See page 51
Connector Box and Cable Guide
Card edge connector · Product

This section contains pinout information for the SPEED LE product range connector box and cable accessories and contains the following;
For details of which cables to use with which product, see Connector Box and Cable Guide on page 43.
Connector Box and Cable Pinouts

RJ45 pin DB25 Pin EIA-232 DIRECTION
2 8 DCD IN
3 20 DTR OUT
4 6 DSR IN
5 7 GND
6 2 TXD OUT
7 3 RxD IN
9 5 CTS IN
10 N/C
1 & Shell 1 & Shell C-GND
Connector Box and Cable Pinouts


RJ45 pin DB9 Pin EIA-232 DIRECTION
2 1 DCD IN
3 4 DTR OUT
4 6 DSR IN
5 5 GND
6 3 TXD OUT
7 2 RXD IN
8 7 RTS OUT
9 8 CTS IN
10 N/C
Connector Box and Cable Pinouts
Shell Shell C-GND




The SPEED LE connector box cable needs to be secured or supported in case of sudden contact or excessive weight on the cables. Please ensure that adequate caution is taken to avoid possible damage to the SPEED LE card or Host system. This can be accomplished by securing the cable to a rack or to the back of the server.
Connector Box and Cable Pinouts


The SPEED LE connector box cable needs to be secured or supported in case of sudden contact or excessive weight on the cables. Please ensure that adequate caution is taken to avoid possible damage to the SPEED LE card or Host system. This can be accomplished by securing the cable to a rack or to the back of the server.
1 & Shell C-GND
3 RXD
4 RTS
5 CTS
6 DSR
7 S-GND
8 DCD
20 DTR
22 RI
Connector Box and Cable Pinouts
DB25 Pin EIA-232


The SPEED LE connector box cable needs to be secured or supported in case of sudden contact or excessive weight on the cables. Please ensure that adequate caution is taken to avoid possible damage to the SPEED LE card or Host system. This can be accomplished by securing the cable to a rack or to the back of the server.
2 RXD
3 TXD
4 DTR
5 S-GND
6 DSR
7 RTS
8 CTS
9 RI
Connector Box and Cable Pinouts
DB9 Pin EIA-232 · Shell C-GND




The SPEED LE fan-out cables need to be secured or supported in case of sudden contact or excessive weight on the cables. Please ensure that adequate caution is taken to avoid possible damage to the SPEED LE card or Host system. This can be accomplished by securing the cables to a rack or to the back of the server.
Connector Box and Cable Pinouts


The SPEED LE fan-out cables need to be secured or supported in case of sudden contact or excessive weight on the cables. Please ensure that adequate caution is taken to avoid possible damage to the SPEED LE card or Host system. This can be accomplished by securing the cables to a rack or to the back of the server.
2 RXD
3 TXD
4 DTR
5 S-GND
6 DSR
7 RTS
8 CTS
9 RI
Connector Box and Cable Pinouts
DB9 Pin EIA-232 · Shell C-GND

The SPEED LE and SPEED LE Express cards come fitted with standard brackets. Additional low profile brackets are included with your SPEED LE and SPEED LE Express cards to accomodate low profile servers. This section describes how to convert your SPEED LE and SPEED LE Express cards from standard to low profile brackets.
To convert a standard profile bracket to a low profile bracket(s) and install it, do the following:
Speed LE 1P and 1S1P models only
Gently remove the serial/parallel connector(s) from the standard bracket and unscrew the bracket from the serial card. You will see two screws that need to be removed at the top and the bottom of the card near the bracket.
Speed LE 1P and 1S1P models only
Align the serial card on top of the low profile bracket mounting tabs and then insert screws into the serial card holes (bracket mounting tabs must be under the serial card).
Low Profile Bracket Conversion

You need to read this appendix if you want to...
You need to read this appendix if you want information on troubleshooting problems with SPEED LE or SPEED LE Express serial adaptor cards.
This appendix provides examples of normal boot up messages and a table of error messages, their meaning and corrective action required for the all the currently supported operating systems.
This appendix includes the following section, Windows 2000/XP/Server 2003/Vista/Server 2008 on page 54.
SPEED LE Serial Adaptor

This section describes troubleshooting SPEED LE products under the Windows 2000, Windows XP, Windows Server 2003, Windows Vista, or Windows Server 2008 operating systems and includes the following sections;
To contact Perle for technical support, see Appendix B: Contacting Perle.
SPEED LE Serial Adaptor Windows 2000/XP/Server 2003/Vista/Server 2008

Machine fails to boot. 1. Turn off your machine, remove SPEED LE card(s) and reboot. See page 30.
Windows operating system fails while loading and the system hangs.
Windows operating system fails while loading and displays a blue screen.
Operating system loads OK, but SPEED driver or another driver fails to boot
SPEED LE ports do not work after installation. 1. Check the Windows Event Log and follow the suggested actions.
SPEED Windows driver fails during normal operation, symptom: blue screen
SPEED Windows driver fails during normal operation, symptoms either: black screen, machine reboots or system hangs
In the event of any error messages, check the Windows Event Log. Also open the Windows Device Manager and check for warming icons on the installed hardware. See your Windows 2000, Windows XP, Windows Server 2003, or Windows Server 2008 user documentation or help system for details.
For general problems, see General Troubleshooting under Windows 2000/XP/Server 2003/Vista/Server 2008 on page 55.
SPEED LE Serial Adaptor Windows 2000/XP/Server 2003/Vista/Server 2008
Problem Action required

You need to read this appendix if you want to...
You need to read this appendix if you want to contact Perle for technical support or any other queries about this product.
This appendix includes the following sections;
Click here to access the our website at the following URL:
Click here to email Perle at the following address;
This section contains the following information about making a query;
If you bought your product from a registered Perle supplier, you must contact their Technical Support department; they are qualified to deal with your problem.
If you are a registered Perle supplier, and bought your product from Perle, contact Perle Technical Support at the offices listed below.
Making a technical support query
Internet access · Email

When you make a technical support enquiry please have the following information ready;
Item Write details here
Product name and version
Details of any other cards installed in your system
Email address (if available)
Making a technical support query

If you have an internet connection, please send details of your problem to Technical Support using the email links provided on the Perle web site in the ‘Support’ area.
See also Perle support centres worldwide on page 59 for email links and other contact details for the Perle technical support centres.
Click here to access our website at the following URL:
Before sending a unit for repair, you must contact your Perle supplier. If, however, you bought your product directly from Perle you can contact directly. See Perle support centres worldwide on page 59 for contact information.
Customers who are In Europe, Africa or Middle East can submit repair details via a website form shown in the next picture. This form is on the Perle website, www.perle.com, in the Support area.
Click here to access our web site at the following URL:
http://www.perle.com/support_services/rma_form.asp
In the USA and Asia contact the office shown in the Technical Support section. Feedback about this manual
If you have any comments or suggestions for improving this manual please email Perle using the following address;
ptact@perle.com
Please include the title, part number and date of the manual (you can find these on the title page at the front of this manual).
Repair procedure

Perle offers free technical support to Perle Authorised Distributors and Registered Perle Resellers.
To access technical support please visit the Perle website at www.perle.com/support_services/index.shtml
If you are unable to find the information you require, please feel free to contact our technical support teams by email using the addresses shown in the next table.
North America Perle Systems Ltd. 60 Renfrew Drive Markham Ontario Canada L3R OE1
Europe Perle Systems Europe Ltd. 3 Wintersells Road Byfleet Surrey KT14 7LF UK
Asia Perle Asia Pacific (Pte) Ltd. 190 Middle Road #19-05 Fortune Centre Singapore 188979
Worldwide Perle Systems Ltd. 60 Renfrew Drive Markham Ontario Canada L3R OE1
SPEED LE and SPEED LE Express Serial Adapters
SPEED LE and SPEED LE Express Serial Adapters Perle support centres worldwide

Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Machine fails to boot. | 1. Turn off your machine, remove SPEED LE card(s) and reboot. See page 30. 2. Try installing a different host card in case the one currently installed is faulty. See page 27. | p.55 | |
| Windows operating system fails while loading and the system hangs. | 1. Reboot machine and then switch to the last known good configuration. 2. Check for resource conflicts or faulty hardware. | p.55 | |
| Windows operating system fails while loading and displays a blue screen. | 1. Note the five hexadecimal numbers at the top line of the screen 2. Reboot your machine and then switch to the last known good configuration. 3. Check for resource conflicts or faulty hardware. | p.55 | |
| Operating system loads OK, but SPEED driver or another driver fails to boot | 1. Run Windows Device Manager to find available IRQ and memory addresses. | p.55 | |
| SPEED LE ports do not work after installation. | 1. Check the Windows Event Log and follow the suggested actions. | p.55 | |
| SPEED Windows driver fails during normal operation, symptom: blue screen | 1. Note the five hexadecimal numbers displayed at the top line of the screen. 2. Reboot your machine and then switch to the last known good configuration. 3. Check for resource conflicts or faulty hardware. | p.55 | |
| SPEED Windows driver fails during normal operation, symptoms either: black screen, machine reboots or system hangs | 1. Contact Technical Support. See Appendix B: Contacting Perle. | p.55 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.