EN
Pelco logo
Official user manual

Pelco DRD14

28 pages·148 KB·Security Camera·PDF·ENDEFRITNLJA
Pelco DRD14
Table of Contents 48 sections List of Illustrations · 1 PC Board Locations · 2 CPU Board · 3 R26/R27 Adjustment Location · … ShowHide
Page 1 of the Pelco DRD14 user manual — DRD08/DRD14 Series
Page 1 · click to enlarge
Page 1

DRD08/DRD14 Series

Receiver/Drivers for

Intercept ® Series

Domes

Installation/ Operation Manual

C466M-E (6/99)

  • Pelco
  • 3500 Pelco Way, Clovis
  • CA 93612-5699 USA
  • <a href="http://www.pelco.com" rel="nofollow noopener" target="_blank">www.pelco.com</a> In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International CustomersTel (1-559) 292-1981 or FAX (1-559) 348-1120
Page 5 of the Pelco DRD14 user manual — Please thoroughly familiarize yourself with the information
Page 5 · click to enlarge
Page 5

1.0 GENERAL

1.1 IMPORTANT SAFEGUARDS AND WARNINGS

Prior to installation and use of this product, the following WARNINGS should be observed.

1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four (4) times the weight of the enclosure, pan/tilt, camera and lens combination.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

CAUTION:

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK,

DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING

TO QUALIFIED SERVICE PERSONNEL.

Please thoroughly familiarize yourself with the information

in this manual prior to installation and operation.

Page 6 of the Pelco DRD14 user manual — 2.1 MODELS
Page 6 · click to enlarge
Page 6

2.0 DESCRIPTION

The DRD08 Series of receiver/drivers is part of the IDS08 Intercept® Series of domes. The IDS08 Series is an integral system that includes a back box (BB08), dome drive (DD08), dome receiver/driver (DRD08), and imager/optics package (IOP08). This manual covers the DRD08 Series of receiver/drivers. For installation and op- eration instructions for the back box, refer to manual C456M-D; for the dome drive, refer to C416M-C; and for the imager/optics package, refer to C1441M-C.

The DRD14 Series of receiver/drivers is part of the IDS14 Series of domes. The IDS14 Series is an integral system that includes a back box (BB14), dome drive (DD14), and dome receiver/driver (DRD14). This manual covers the DRD14 Series of receiver/drivers. For installation and operation instructions for the back box, refer to manual C454M-C, and the the dome drive, refer to manual C458M-B.

2.1 MODELS

DRD08A11 Receiver/driver for 8" Intercept® dome series. Basic receiver for fixed-speed dome drive. Coaxitron® control.

DRD14A11 Same as DRD08A11 except for use with 14" Intercept® dome series.

DRD14A12 Receiver/driver for 14" Intercept® dome series. Basic receiver for variable-speed dome drive. Coaxitron® control.

DRD08A21 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with fixed-speed dome drive. Coaxitron® control.

DRD14A21 Same as DRD08A21 except for use with 14" Intercept® dome series.

DRD08A22 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with variable-speed dome drive. Coaxitron® control.

DRD14A22 Same as DRD08A22 except for use with 14" Intercept® dome series.

DRD08D11 Receiver/driver for 8" Intercept® dome series. Basic receiver for fixed-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Trans- lator.

DRD14D11 Same as DRD08D11 except for use with 14" Intercept® dome series.

DRD14D12 Receiver/driver for 8" Intercept® dome series. Basic receiver for variable-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Trans- lator.

DRD08D21 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with fixed-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Translator.

DRD14D21 Same as DRD08D21 except for use with 14" Intercept® dome series.

Page 7 of the Pelco DRD14 user manual — 2.0 DESCRIPTION
Page 7 · click to enlarge
Page 7

DRD08D22 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with variable-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Trans- lator.

DRD14D22 Same as DRD08D22 except for use with 14" Intercept® dome series.

DRD08P11 Receiver/driver for 8" Intercept® dome series. Basic receiver for fixed-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.

DRD14P11 Same as DRD08P11 except for use with 14" Intercept® dome series.

DRD14P12 Receiver/driver for 8" Intercept® dome series. Basic receiver for variable-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.

DRD08P21 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with fixed-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.

DRD14P21 Same as DRD08P21 except for use with 14" Intercept® dome series.

DRD08P22 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with variable-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.

DRD14P22 Same as DRD08P22 except for use with 14" Intercept® dome series.

Page 8 of the Pelco DRD14 user manual — 3.1.3 DC Power Supply Board PCB8500140
Page 8 · click to enlarge
Page 8

3.0 INSTALLATION

Installation of the Dome Receiver/Driver (DRD) into the DD08 or DD14 Dome Drive is accomplished at the factory. This is not a field installable option.

3.1 ADJUSTMENTS

Although the DRD has been adjusted and set at the factory, some settings can and may require field adjusting.

3.1.1 CPU Board

1. JP3 is set at the factory in the RS-485 (422) position. Leave it in this position.
2. JP5 and JP6 are both set in the UNTERM (unterminated) position. If the receiver is using RS-422 and is the last physical receiver in the chain, then the setting must be moved to the TERM (terminating) position (refer to Figures 1 and 2).
3. JP1 and JP2 are used to decode the EPROM. They are factory set JP1 pin 2 to JP1 pin 3 and JP2 pin 1 to JP2 pin 2. DO NOT ALTER.
4. SW1 receiver address switch is for those units whose firmware supports either Dor P-type protocol. Refer to Figures 1 and 2 for the switch location. Refer to Table A to set the receiver address for units that use D-type protocol. Refer to Table B to set the receiver address and baud for units that use P-type protocol.

3.1.2 AC Power Supply Board PCB8500130

R26 20k ohm potentiometer sets the lens voltage. It is set at the factory at 10 volts. Refer to Figures 1 and 3. Refer to Section 4.2 for more information.

3.1.3 DC Power Supply Board PCB8500140

POWER CPU B VIDEO BOARD (COAXITRON® MODELSS O OU AR NLPPLY BOARD D Y) Figure 1. PC Board Locations
Page 9 of the Pelco DRD14 user manual — 2 CPU Board
Page 9 · click to enlarge
Page 9
Pelco DRD14 — 2 CPU Board diagram (page 9)
Fig. 1 · 2 CPU Board

1 2 3 4 5 6 7 8 MADE IN USA PCB8500110D

Figure 2. CPU Board

Pelco DRD14 — 2 CPU Board diagram (page 9)
Fig. 2 · 2 CPU Board

Figure 3. R26/R27 Adjustment Location

Page 10 of the Pelco DRD14 user manual — B Switch Settings for SW1 - P-Type Control
Page 10 · click to enlarge
Page 10

Table B. Switch Settings for SW1 - P-Type Control

For D-type control systems, refer to Table A.

Receiver Address Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5

1 ON 2 OFF ON 3 ON OFF ON ON ON 4 OFF OFF ON ON ON 5 ON ON OFF ON ON 6 OFF ON OFF ON ON 7 ON OFF OFF ON ON 8 OFF OFF OFF ON ON 9 ON ON ON OFF ON 10 OFF ON ON OFF ON 11 ON OFF ON OFF ON 12 OFF OFF ON OFF ON 13 ON ON OFF OFF ON 14 OFF ON OFF OFF ON 15 ON OFF OFF OFF ON 16 OFF ON 17 ON OFF 18 OFF ON ON ON OFF 19 ON OFF ON ON OFF 20 OFF OFF ON ON OFF 21 ON ON OFF ON OFF 22 OFF ON OFF ON OFF 23 ON OFF OFF ON OFF 24 OFF OFF OFF ON OFF 25 ON ON ON OFF OFF 26 OFF ON ON OFF OFF 27 ON OFF ON OFF OFF 28 OFF OFF ON OFF OFF 29 ON ON OFF OFF OFF 30 OFF ON OFF OFF OFF 31 ON OFF 32 OFF

Baud Switch Setting SW1-6 SW1-7 SW1-8

9600 OFF ON ON 4800 ON OFF ON 2400 ON ON OFF

Page 11 of the Pelco DRD14 user manual — 4.2 PTZ (PAN/TILT AND LENS) CONTROLS
Page 11 · click to enlarge
Page 11

4.0 OPERATION

Upon applying power, the unit starts a configuration routine after 15 seconds.

4.1 SCAN OPERATION

Three (3) different scan mode options are offered and can be selected according to operator preference:

Auto Scan; (AUX 2), continuous panning, with a 5-second stop on limits.

Random Scan; (AUX 3) random operation.

Frame Scan; (AUX 4) with 5 seconds of travel followed by 5 seconds of stop.

To select a scan mode (at the system controller), select the appropriate AUX but- ton, then select scan.

4.2 PTZ (PAN/TILT AND LENS) CONTROLS

1. The DRD08**2 pan mechanism under standard operator control will move at less than one (1) degree per second and as fast as 40 degrees per second. In the preset or turbo mode, the unit will pan at greater than 200 degrees per second.
2. The DRD14**2 pan mechanism under standard operator control will move at less than one (1) degree per second and as fast as 20 degrees per second. In the preset or turbo mode, the unit will pan at greater than 100 degrees per second.
3. The DRD08**2 tilt mechanism under standard operator control will move at less than one (1) degree per second and as fast as 40 degrees per second. In preset mode, the unit will tilt at 90 degrees per second.
4. The DRD14**2 tilt mechanism under standard operator control will move at less than one (1) degree per second and as fast as 40 degrees per second. In preset mode, the unit will tilt at 45 degrees per second.
5. The DRD***2* lens functions are dependent on the lens used. The lens voltage can be set as described in section 3.1.2 or 3.1.3, depending on which is applicable. This voltage will set the highest speed at which the lens can move. For slower speeds the DRD can be programmed by the controller for 3/4 and 1/2 of this speed as described in the firmware section of this manual.
Page 12 of the Pelco DRD14 user manual — 4.5 ZONES
Page 12 · click to enlarge
Page 12

4.3 PRESET FUNCTIONS

1. The DRD***2* units are capable of 32 complete preset scenes. On DRD**A2* models, each preset can have a 20-character label. To set a preset, first enter the label then program the position.
2. Once programmed, the DRD***2* can be commanded to the preset. Resolution of the pan and tilt position is 1/2 degree.
3. There are two (2) additional presets that can be programmed; they are preset 33 “FLIP” command which will pan the dome drive 180 degrees from the position it is at, and preset 34 “PAN ZERO” which will direct the dome drive to the factory determined zero reference point.

The following applies to dome firmware revision PRG08A21U3-R2.2 and higher for DRD08A21 and DRD14A21 dome receiver/driver types.

With pan limit stops installed, and when calling preset 34, the dome will move to the PAN ZERO position. After arriving at this position, the dome may bounce or jitter back and forth in half-degree increments around the zero position. If left undis- turbed, the unit will continue this action until the 60-second time out has been reached. Control of the dome can be resumed at any time by sending a command.

Preset 34 is used in this application to set a zone across the zero position. To accom- plish this in light of the above mentioned problem, follow the procedure outlined below.

1. Send the dome to preset 34.
2. When the dome arrives at the PAN ZERO position and begins to jitter, abort the preset call by actuating a lens function. The dome should now be positioned at the correct position, and the procedure in Section 4.5, ZONES, can be followed.

4.4 FLIP FUNCTION

The flip feature will move the pan position 180 degrees.

4.5 ZONES

1. The DRD**A2* units are capable of 8 zones, each with a 20-character label. To set a zone, first move the unit to the left-most zone point, enter the label, then set the zone start point.
2. Next move the unit to the right to the second position and program the zone end point. The zone priority is from zone 8 to zone 1 with zone 8 having the highest priority. This means if two zones overlap, the one with the highest priority will be displayed.
Page 13 of the Pelco DRD14 user manual — RESET BUTTON
Page 13 · click to enlarge
Page 13

4.6 PATTERNS

1. The DRD***2* units are capable of one 60-second pattern. This pattern can consist of any standard pan/tilt or lens command. Presets, flip and turbo are not allowed in a pattern. Zone scan can be enabled while running a pattern.

2. To program a pattern first move the pan/tilt and adjust the lens to the starting point desired. Engage the Pattern Programming command. The message “PROGRAMMING PATTERN” will be displayed. After this, any movement for the next 60 seconds will be remembered by the DRD. To create a pattern that plays back only once, continue programming until the message is removed. To create a pattern that repeats you must terminate the program before the time-out occurs and the DRD removes the message.

3. To play back a pattern, engage the Run Pattern command. The unit will move to the defined starting position and display the message “RUNNING PATTERN”. Any subsequent command will terminate the pattern.

4.7 CLEAR VIDEO SCREEN

To clear the video display of any text supplied by the DRD, engage the Clear Video Text command.

4.8 RESET

On all units except the DRD***11 models, there is a reset switch on the CPU board (refer to Figure 4). If the dome drive stops working, try resetting it by pushing the reset switch for 10 seconds. In about 15 seconds, if the unit is working, it will begin to move and go through its start-up routine. You may also be able to issue a reset command from your controller; check the documentation for your controller.

RESET BUTTON

Figure 4. Receiver/Driver Reset Button Location

Page 14 of the Pelco DRD14 user manual — 5.1.1 PTZ (Pan/Tilt and Lens) Commands
Page 14 · click to enlarge
Page 14

5.0 FIRMWARE

5.1 COAXITRON CONTROL COMMAND

This section describes the protocol used to send commands to the receivers via Coaxitron.

The hardware interface is a 32-bit PWM (pulse width modulated) signal, wherein a one microsecond pulse is considered a zero and a two microsecond pulse is con- sidered a one. There will be a minimum one (1) microsecond off space between pulses. Line 18 will contain Bytes 1 and 2, line 19 will contain Bytes 3 and 4.

Commands are divided into two (2) categories. The first is referred to as PTZ (pan and tilt and lens) commands; the second category is Extended commands.

5.1.1 PTZ (Pan/Tilt and Lens) Commands

All PTZ (pan/tilt and lens) commands will always have B0 of Byte 2 set to zero. The remainder of the format is as follows:

Byte 1: B7 — Camera on, auto scan B6 — Coaxitron usage only B5 — Coaxitron usage only B4 — Auto scan, manual scan B3 — Camera on, camera off B2 — Iris close B1 — Iris open B0 — Focus near

Byte 2: B7 — Focus far B6 — Zoom wide B5 — Zoom tele B4 — Down B3 — Up B2 — Left B1 — Right B0 — always zero for a PTZ command

Byte 3Pan speed with values 0 to 0x3F and 0xFF (pan turbo)
Byte 4Tilt speed with values 0 to 0x3F

Examples: Left, half Speed 00 04 1F 00 Left, Turbo Speed 00 04 FF 00 Stop 00

Page 15 of the Pelco DRD14 user manual — 5.2 AMERICAN DYNAMICS AD2083 TYPE RS-422 CONTROL COMMAND
Page 15 · click to enlarge
Page 15

5.1.2 Extended Commands

Extended commands will always have B0 of Byte 2 set to one. The following num- bers are in hexadecimal format:

Command Byte 1 Byte 2 Byte 3 Byte 4

Set preset XX 00 03 00 01 to 20

Clear preset XX 00 05 00 01 to 20

Go to preset XX 00 07 00 01 to 20

80 FLIP preset 00 07 00 21

Set aux XX 00 09 00 01 to 08

Clear aux XX 00 0B 00 01 to 08

Remote Reset 00 0F 00 00

Program zone XX starting point 00 11 00 01 to 08

Program zone XX ending point 00 13 00 01 to 08

Write character YY to screen position XX 00 15 0 to 27 YY

Clear screen 00 17 00 00

Zone Scan On 00 1B 00 00

Zone Scan Off 00 1D 00 00

Pattern Start Point 00 1F 00 00

Pattern Stop Point 00 21 00 00

Run Pattern 00 23 00 00

Lens Speed 00 25 00 00 to 03

5.2 AMERICAN DYNAMICS AD2083 TYPE RS-422 CONTROL COMMAND

5.2.1 Protocol

1. The following describes the protocol used to send commands to the receivers via RS-422.

a. The hardware interface is four-wire RS-422, where one pair is used to issue commands to the receiver and one pair is used to receive responses from the receiver.

b. The protocol: one start bit, eight bits data, and one stop bit at 2400 baud.

2. The message format is 7 of these 10-bit words. Word one is the sync and is set to 0xFF, word two is the receiver address, words three and four are referred to as commands, words five and six as data, and word seven is the check sum.

Commands are divided into two categories. The first is referred to as PTZ (pan and tilt and lens) commands, the second category is Extended commands.

Page 16 of the Pelco DRD14 user manual — 5.2.3 PTZ (Pan/Tilt and Lens) Commands
Page 16 · click to enlarge
Page 16

5.2.2 Addressing

The address is set on the CPU board PCB8500110. The switch is labeled SW1. Setting the switch in the “ON” position represents a zero. Refer to Table A.

SW1.1 Address Bit 0 SW1.2 Address Bit 1 SW1.3 Address Bit 2 SW1.4 Address Bit 3 SW1.5 Address Bit 4 SW1.6 Address Bit 5 SW1.7 Address Bit 6 SW1.8 Address Bit 7

5.2.3 PTZ (Pan/Tilt and Lens) Commands

All PTZ (pan/tilt and lens) commands will always have B0 of word 4 set to zero. The remainder of the format is as follows:

Word 3: B7 — Camera on, auto scan B6 — Coaxitron usage only B5 — Coaxitron usage only B4 — Auto scan, manual scan B3 — Camera on, camera off B2 — Iris close B1 — Iris open B0 — Focus near

Word 4: B7 — Focus far B6 — Zoom wide B5 — Zoom tele B4 — Down B3 — Up B2 — Left B1 — Right B0 — Always zero for a PTZ command

Word 5Pan speed with values 0 to 0x3F and 0x40 (pan turbo)
Word 6Tilt speed with values 0 to 0x3F

The following examples are for Words 3, 4, 5 and 6:

Left, Half Speed 00 04 1F 00 Left, Turbo Speed 00 04 40 00 Stop 00

Page 17 of the Pelco DRD14 user manual — 5.3 PELCO “P” TYPE RS-422 CONTROL
Page 17 · click to enlarge
Page 17

5.2.4 Extended Commands

Extended commands will always have B0 of Word 4 set to one. The following num- bers are in hexadecimal format:

Command Word 3 Word 4 Word 5 Word 6

Set preset XX 00 03 00 01 to 20

Clear preset XX 00 05 00 01 to 20

Go to preset XX 00 07 00 01 to 20

180 FLIP preset 00 07 00 21

Zero pan position 00 07 00 22

Set aux XX 00 09 00 01 to 08

Clear aux XX 00 0B 00 01 to 08

Remote Reset 00 0F 00 00

Clear screen 00 17 00 00

Pattern Start Point 00 1F 00 00

Pattern Stop Point 00 21 00 00

Run Pattern 00 23 00 00

Lens Speed 00 25 00 00 to 03

The four word response format is: word one is the sync 0xFF, word 2 is the receiver address, word 3 is the alarm information, and word 4 is a return check sum (which is the transmitted check sum added to the alarm information).

5.3 PELCO “P” TYPE RS-422 CONTROL

5.3.1 Protocol

This section describes the protocol used to send commands to the receivers via RS-422. The hardware interface is four-wire RS-422, where one pair is used to issue commands to the receiver. The protocol is one start bit, eight bits data, and one stop bit at 9600, 4800 or 2400 baud. The message format is 8 of these 10-bit words with the following format:

WORD 1 — STX (0XA0) WORD 2 — ADD (0 to 0X1F) WORD 3 — Data as described below WORD 4 — Data as described below WORD 5 — Data as described below WORD 6 — Data as described below WORD 7 — ETX (0XAF) WORD 8 — CRC

Page 18 of the Pelco DRD14 user manual — 5.3.4.1 PTZ (Pan/Tilt and Zoom) Commands
Page 18 · click to enlarge
Page 18

5.3.2 Addressing

The address is set on the CPU board PCB8500110. The switch is labeled SW1. Setting the switch in the “ON” position represents a zero. The first five positions set the receiver address (1 through 5) from a range of 0 to 31. The last three (6 through 8) set the baud rate. Refer to Table B.

SW1.1 — Address Bit 0 SW1.2 — Address Bit 1 SW1.3 — Address Bit 2 SW1.4 — Address Bit 3 SW1.5 — Address Bit 4 SW1.6 — 9600 Baud SW1.7 — 4800 Baud SW1.8 — 2400 Baud

5.3.3 Receiver Cards

The RS-422 style Intercept® receivers use only two of the three receiver cards. There must be a power supply (either AC or DC) and a CPU card. The video card is not used. Therefore the camera video output is connected directly to the slip ring. This eliminates the dome’s ability to superimpose text on the video. This eliminates any label and zone feature. If these features are needed additional firmware will be needed.

5.3.4 Commands

Commands are divided into two (2) categories. The first is referred to as PTZ com- mands. The second category is Extended commands. The paragraphs below de- scribe their functions.

5.3.4.1 PTZ (Pan/Tilt and Zoom) Commands

PTZ commands will always have B0 of word 4 set to zero. The remainder of the format is as follows.

Word 3 B7 — Always Zero (was camera on, auto scan) B6 — Camera On (was Coaxitron usage only) B5 — Auto Scan On (was Coaxitron only) B4 — Camera On, Camera Off (was auto scan, manual scan) B3 — Iris Close B2 — Iris Open B1 — Focus Near B0 — Focus Far

Word 4 B7 — Always Zero B6 — Zoom Wide B5 — Zoom Tele B4 — Down B3 — Up B2 — Left B1 — Right B0 — Always Zero for PTZ command

Word 5 Pan speed with values 0 to 0x3F and 0xx40 (Pan Turbo)

Word 6 Tilt speed with values 0 to 0x3F

Page 19 of the Pelco DRD14 user manual — 5.3.5 Acknowledgment
Page 19 · click to enlarge
Page 19

5.3.4.2 Extended Commands

Extended commands will always have B0 of Word 4 set to 1. The numbers below are in hexadecimal format.

Command Word 3 Word 4 Word 5 Word 6

Set preset XX 00 03 00 01 to 20

Clear preset XX 00 05 00 01 to 20

Go to preset XX 00 07 00 01 to 20

180 Flip preset 00 07 00 21

Zero pan position 00 07 00 22

Set aux XX 00 09 00 01 to 08

Clear aux XX 00 0B 00 01 to 08

Remote Reset 00 0F 00 00

Pat. Start Point 00 1F 00 00

Pat. Stop Point 00 21 00 00

Run Pattern 00 23 00 00

Zoom Lens speed 00 25 00 00 to 03

Focus Lens speed 00 27 00 00 to 03

5.3.5 Acknowledgment

The receiver will respond with an ACK (0XA2).

Page 20 of the Pelco DRD14 user manual — 6.0 CIRCUIT BOARD PARTS LIST
Page 20 · click to enlarge
Page 20

6.0 CIRCUIT BOARD PARTS LIST

Table C. Circuit Board Parts List

Model CPU Board Video Board Power Board Backplane

DRD08A11 CPU08A11ASSY PCB8500101ASSY PCB8500130ASSY PCB8500150ASSY DRD08D11 CPU08D11ASSY PCB8500130ASSY PCB8500151ASSY DRD08P11 CPU08P11ASSY PCB8500130ASSY PCB8500151ASSY DRD08A21 CPU08A21ASSY PCB8500100ASSY PCB8500130ASSY PCB8500150ASSY DRD08D21 CPU08D21ASSY PCB8500130ASSY PCB8500151ASSY DRD08P21 CPU08P21ASSY PCB8500130ASSY PCB8500151ASSY DRD08A22 CPU08A22ASSY PCB8500100ASSY PCB8500140ASSY PCB8500150ASSY DRD08D22 CPU08D22ASSY PCB8500140ASSY PCB8500151ASSY DRD08P22 CPU08P22ASSY PCB8500140ASSY PCB8500151ASSY

DRD14A11 CPU14A11ASSY PCB8500101ASSY PCB8500130ASSY PCB8500150ASSY DRD14D11 CPU14D11ASSY PCB8500130ASSY PCB8500151ASSY DRD14P11 CPU14P11ASSY PCB8500130ASSY PCB8500151ASSY DRD14A12 CPU14A12ASSY PCB8500101ASSY PCB8500140ASSY PCB8500150ASSY DRD14D12 CPU14D12ASSY PCB8500140ASSY PCB8500151ASSY DRD14P12 CPU14P12ASSY PCB8500140ASSY PCB8500151ASSY DRD14A21 CPU14A21ASSY PCB8500100ASSY PCB8500130ASSY PCB8500150ASSY DRD14D21 CPU14D21ASSY PCB8500130ASSY PCB8500151ASSY DRD14P21 CPU14P21ASSY PCB8500130ASSY PCB8500151ASSY DRD14A22 CPU14A22ASSY PCB8500100ASSY PCB8500140ASSY PCB8500150ASSY DRD14D22 CPU14D22ASSY PCB8500140ASSY PCB8500151ASSY DRD14P22 CPU14P22ASSY PCB8500140ASSY PCB8500151ASSY

Page 21 of the Pelco DRD14 user manual — 7.0 SPECIFICATIONS
Page 21 · click to enlarge
Page 21

7.0 SPECIFICATIONS

Input Voltage24 VAC, 60 Hz, ± 10% at the drive
AC Motor Dome DrivePan — 7.5 vA Tilt — 7.5 vA Idle — 2.5 vA

DC Stepper Motor Dome Drive: Pan — 32 vA Tilt — 32 vA Pan/Tilt — 48 vA Idle — 15 vA

Camera Output Voltage24 VAC
Lens Output Voltage9 to 12 VDC (Bi-polar)
Video Input Level0.5 to 1.5 volts peak to peak
Video Input FormatNTSC or EIA
Video Bandwidth10 MHz
Baud Rate1 MHz

(Design and product specifications subject to change without notice.)

This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.

Maximum Input Power

Page 22 of the Pelco DRD14 user manual — 7.1 REGULATORY NOTICES
Page 22 · click to enlarge
Page 22

7.1 REGULATORY NOTICES

NOTE: This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfer- ence at his own expense.

Page 23 of the Pelco DRD14 user manual — 8.0 WARRANTY AND RETURN INFORMATION
Page 23 · click to enlarge
Page 23

8.0 WARRANTY AND RETURN INFORMATION

  • WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below:
  • Five years on FT/FR8000 Series fiber optic products.
  • Three years on Genex ® Series products (multiplexers, server, and keyboard).
  • Three years on Camclosure ® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a fiveyear warranty.
  • Two years on standard motorized or fixed focal length lenses.
  • Two years on Legacy ® , CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
  • Two years on Spectra ® , Esprit ® , ExSite ™ , and PS20 scanners, including when used in continuous motion applications.
  • Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades).
  • Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura ™ Series distributed network-based video products.
  • One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
  • Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes). Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty. Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise. The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information: 1. Model and serial number 2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number 3. Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned. Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.

RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below. If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:

Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699 If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following: If the goods are to be sent by a COURIER SERVICE, send the goods to:

Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:

Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco.

Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933

© Copyright 1999, Pelco. All rights reserved.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Pelco DRD14

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Pelco DRD14

Be the first to ask — other owners or our team will answer.

Original document

Pelco DRD14 manual PDF

28 pages·148 KB·Security Camera·PDF
Click any page above to open it here
Page 1 / …
100%