Receiver/Drivers for
Intercept ® Series
Domes
Installation/ Operation Manual
C466M-E (6/99)


Prior to installation and use of this product, the following WARNINGS should be observed.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
DO NOT REMOVE COVER. NO USER- SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
in this manual prior to installation and operation.

The DRD08 Series of receiver/drivers is part of the IDS08 Intercept® Series of domes. The IDS08 Series is an integral system that includes a back box (BB08), dome drive (DD08), dome receiver/driver (DRD08), and imager/optics package (IOP08). This manual covers the DRD08 Series of receiver/drivers. For installation and op- eration instructions for the back box, refer to manual C456M-D; for the dome drive, refer to C416M-C; and for the imager/optics package, refer to C1441M-C.
The DRD14 Series of receiver/drivers is part of the IDS14 Series of domes. The IDS14 Series is an integral system that includes a back box (BB14), dome drive (DD14), and dome receiver/driver (DRD14). This manual covers the DRD14 Series of receiver/drivers. For installation and operation instructions for the back box, refer to manual C454M-C, and the the dome drive, refer to manual C458M-B.
DRD08A11 Receiver/driver for 8" Intercept® dome series. Basic receiver for fixed-speed dome drive. Coaxitron® control.
DRD14A11 Same as DRD08A11 except for use with 14" Intercept® dome series.
DRD14A12 Receiver/driver for 14" Intercept® dome series. Basic receiver for variable-speed dome drive. Coaxitron® control.
DRD08A21 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with fixed-speed dome drive. Coaxitron® control.
DRD14A21 Same as DRD08A21 except for use with 14" Intercept® dome series.
DRD08A22 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with variable-speed dome drive. Coaxitron® control.
DRD14A22 Same as DRD08A22 except for use with 14" Intercept® dome series.
DRD08D11 Receiver/driver for 8" Intercept® dome series. Basic receiver for fixed-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Trans- lator.
DRD14D11 Same as DRD08D11 except for use with 14" Intercept® dome series.
DRD14D12 Receiver/driver for 8" Intercept® dome series. Basic receiver for variable-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Trans- lator.
DRD08D21 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with fixed-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Translator.
DRD14D21 Same as DRD08D21 except for use with 14" Intercept® dome series.

DRD08D22 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with variable-speed dome drive. D-type control: RS-422 compatible with Pelco’s MPT9500, CM6700 and CM8500 controllers or with American Dynamics controllers using the AD2083 Trans- lator.
DRD14D22 Same as DRD08D22 except for use with 14" Intercept® dome series.
DRD08P11 Receiver/driver for 8" Intercept® dome series. Basic receiver for fixed-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.
DRD14P11 Same as DRD08P11 except for use with 14" Intercept® dome series.
DRD14P12 Receiver/driver for 8" Intercept® dome series. Basic receiver for variable-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.
DRD08P21 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with fixed-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.
DRD14P21 Same as DRD08P21 except for use with 14" Intercept® dome series.
DRD08P22 Receiver/driver for 8" Intercept® dome series. Enhanced re- ceiver with preset positioning, zones, and patterns. For use with variable-speed dome drive. P-type control: RS-422 compatible with Pelco’s CM6700 and CM9750/CM9760 control systems.
DRD14P22 Same as DRD08P22 except for use with 14" Intercept® dome series.

Installation of the Dome Receiver/Driver (DRD) into the DD08 or DD14 Dome Drive is accomplished at the factory. This is not a field installable option.
Although the DRD has been adjusted and set at the factory, some settings can and may require field adjusting.
R26 20k ohm potentiometer sets the lens voltage. It is set at the factory at 10 volts. Refer to Figures 1 and 3. Refer to Section 4.2 for more information.


1 2 3 4 5 6 7 8 MADE IN USA PCB8500110D
Figure 2. CPU Board

Figure 3. R26/R27 Adjustment Location

Table B. Switch Settings for SW1 - P-Type Control
For D-type control systems, refer to Table A.
Receiver Address Switch Setting SW1-1 SW1-2 SW1-3 SW1-4 SW1-5
1 ON 2 OFF ON 3 ON OFF ON ON ON 4 OFF OFF ON ON ON 5 ON ON OFF ON ON 6 OFF ON OFF ON ON 7 ON OFF OFF ON ON 8 OFF OFF OFF ON ON 9 ON ON ON OFF ON 10 OFF ON ON OFF ON 11 ON OFF ON OFF ON 12 OFF OFF ON OFF ON 13 ON ON OFF OFF ON 14 OFF ON OFF OFF ON 15 ON OFF OFF OFF ON 16 OFF ON 17 ON OFF 18 OFF ON ON ON OFF 19 ON OFF ON ON OFF 20 OFF OFF ON ON OFF 21 ON ON OFF ON OFF 22 OFF ON OFF ON OFF 23 ON OFF OFF ON OFF 24 OFF OFF OFF ON OFF 25 ON ON ON OFF OFF 26 OFF ON ON OFF OFF 27 ON OFF ON OFF OFF 28 OFF OFF ON OFF OFF 29 ON ON OFF OFF OFF 30 OFF ON OFF OFF OFF 31 ON OFF 32 OFF
Baud Switch Setting SW1-6 SW1-7 SW1-8
9600 OFF ON ON 4800 ON OFF ON 2400 ON ON OFF

Upon applying power, the unit starts a configuration routine after 15 seconds.
Three (3) different scan mode options are offered and can be selected according to operator preference:
Auto Scan; (AUX 2), continuous panning, with a 5-second stop on limits.
Random Scan; (AUX 3) random operation.
Frame Scan; (AUX 4) with 5 seconds of travel followed by 5 seconds of stop.
To select a scan mode (at the system controller), select the appropriate AUX but- ton, then select scan.

The following applies to dome firmware revision PRG08A21U3-R2.2 and higher for DRD08A21 and DRD14A21 dome receiver/driver types.
With pan limit stops installed, and when calling preset 34, the dome will move to the PAN ZERO position. After arriving at this position, the dome may bounce or jitter back and forth in half-degree increments around the zero position. If left undis- turbed, the unit will continue this action until the 60-second time out has been reached. Control of the dome can be resumed at any time by sending a command.
Preset 34 is used in this application to set a zone across the zero position. To accom- plish this in light of the above mentioned problem, follow the procedure outlined below.
The flip feature will move the pan position 180 degrees.

2. To program a pattern first move the pan/tilt and adjust the lens to the starting point desired. Engage the Pattern Programming command. The message “PROGRAMMING PATTERN” will be displayed. After this, any movement for the next 60 seconds will be remembered by the DRD. To create a pattern that plays back only once, continue programming until the message is removed. To create a pattern that repeats you must terminate the program before the time-out occurs and the DRD removes the message.
To clear the video display of any text supplied by the DRD, engage the Clear Video Text command.
On all units except the DRD***11 models, there is a reset switch on the CPU board (refer to Figure 4). If the dome drive stops working, try resetting it by pushing the reset switch for 10 seconds. In about 15 seconds, if the unit is working, it will begin to move and go through its start-up routine. You may also be able to issue a reset command from your controller; check the documentation for your controller.
Figure 4. Receiver/Driver Reset Button Location

This section describes the protocol used to send commands to the receivers via Coaxitron.
The hardware interface is a 32-bit PWM (pulse width modulated) signal, wherein a one microsecond pulse is considered a zero and a two microsecond pulse is con- sidered a one. There will be a minimum one (1) microsecond off space between pulses. Line 18 will contain Bytes 1 and 2, line 19 will contain Bytes 3 and 4.
Commands are divided into two (2) categories. The first is referred to as PTZ (pan and tilt and lens) commands; the second category is Extended commands.
All PTZ (pan/tilt and lens) commands will always have B0 of Byte 2 set to zero. The remainder of the format is as follows:
Byte 1: B7 — Camera on, auto scan B6 — Coaxitron usage only B5 — Coaxitron usage only B4 — Auto scan, manual scan B3 — Camera on, camera off B2 — Iris close B1 — Iris open B0 — Focus near
Byte 2: B7 — Focus far B6 — Zoom wide B5 — Zoom tele B4 — Down B3 — Up B2 — Left B1 — Right B0 — always zero for a PTZ command
Examples: Left, half Speed 00 04 1F 00 Left, Turbo Speed 00 04 FF 00 Stop 00

Extended commands will always have B0 of Byte 2 set to one. The following num- bers are in hexadecimal format:
Command Byte 1 Byte 2 Byte 3 Byte 4
Set preset XX 00 03 00 01 to 20
Clear preset XX 00 05 00 01 to 20
Go to preset XX 00 07 00 01 to 20
80 FLIP preset 00 07 00 21
Set aux XX 00 09 00 01 to 08
Clear aux XX 00 0B 00 01 to 08
Remote Reset 00 0F 00 00
Program zone XX starting point 00 11 00 01 to 08
Program zone XX ending point 00 13 00 01 to 08
Write character YY to screen position XX 00 15 0 to 27 YY
Clear screen 00 17 00 00
Zone Scan On 00 1B 00 00
Zone Scan Off 00 1D 00 00
Pattern Start Point 00 1F 00 00
Pattern Stop Point 00 21 00 00
Run Pattern 00 23 00 00
Lens Speed 00 25 00 00 to 03
5.2.1 Protocol
a. The hardware interface is four-wire RS-422, where one pair is used to issue commands to the receiver and one pair is used to receive responses from the receiver.
b. The protocol: one start bit, eight bits data, and one stop bit at 2400 baud.
Commands are divided into two categories. The first is referred to as PTZ (pan and tilt and lens) commands, the second category is Extended commands.

The address is set on the CPU board PCB8500110. The switch is labeled SW1. Setting the switch in the “ON” position represents a zero. Refer to Table A.
SW1.1 Address Bit 0 SW1.2 Address Bit 1 SW1.3 Address Bit 2 SW1.4 Address Bit 3 SW1.5 Address Bit 4 SW1.6 Address Bit 5 SW1.7 Address Bit 6 SW1.8 Address Bit 7
All PTZ (pan/tilt and lens) commands will always have B0 of word 4 set to zero. The remainder of the format is as follows:
Word 3: B7 — Camera on, auto scan B6 — Coaxitron usage only B5 — Coaxitron usage only B4 — Auto scan, manual scan B3 — Camera on, camera off B2 — Iris close B1 — Iris open B0 — Focus near
Word 4: B7 — Focus far B6 — Zoom wide B5 — Zoom tele B4 — Down B3 — Up B2 — Left B1 — Right B0 — Always zero for a PTZ command
The following examples are for Words 3, 4, 5 and 6:
Left, Half Speed 00 04 1F 00 Left, Turbo Speed 00 04 40 00 Stop 00

Extended commands will always have B0 of Word 4 set to one. The following num- bers are in hexadecimal format:
Command Word 3 Word 4 Word 5 Word 6
Set preset XX 00 03 00 01 to 20
Clear preset XX 00 05 00 01 to 20
Go to preset XX 00 07 00 01 to 20
180 FLIP preset 00 07 00 21
Zero pan position 00 07 00 22
Set aux XX 00 09 00 01 to 08
Clear aux XX 00 0B 00 01 to 08
Remote Reset 00 0F 00 00
Clear screen 00 17 00 00
Pattern Start Point 00 1F 00 00
Pattern Stop Point 00 21 00 00
Run Pattern 00 23 00 00
Lens Speed 00 25 00 00 to 03
The four word response format is: word one is the sync 0xFF, word 2 is the receiver address, word 3 is the alarm information, and word 4 is a return check sum (which is the transmitted check sum added to the alarm information).
5.3.1 Protocol
This section describes the protocol used to send commands to the receivers via RS-422. The hardware interface is four-wire RS-422, where one pair is used to issue commands to the receiver. The protocol is one start bit, eight bits data, and one stop bit at 9600, 4800 or 2400 baud. The message format is 8 of these 10-bit words with the following format:
WORD 1 — STX (0XA0) WORD 2 — ADD (0 to 0X1F) WORD 3 — Data as described below WORD 4 — Data as described below WORD 5 — Data as described below WORD 6 — Data as described below WORD 7 — ETX (0XAF) WORD 8 — CRC

The address is set on the CPU board PCB8500110. The switch is labeled SW1. Setting the switch in the “ON” position represents a zero. The first five positions set the receiver address (1 through 5) from a range of 0 to 31. The last three (6 through 8) set the baud rate. Refer to Table B.
SW1.1 — Address Bit 0 SW1.2 — Address Bit 1 SW1.3 — Address Bit 2 SW1.4 — Address Bit 3 SW1.5 — Address Bit 4 SW1.6 — 9600 Baud SW1.7 — 4800 Baud SW1.8 — 2400 Baud
The RS-422 style Intercept® receivers use only two of the three receiver cards. There must be a power supply (either AC or DC) and a CPU card. The video card is not used. Therefore the camera video output is connected directly to the slip ring. This eliminates the dome’s ability to superimpose text on the video. This eliminates any label and zone feature. If these features are needed additional firmware will be needed.
Commands are divided into two (2) categories. The first is referred to as PTZ com- mands. The second category is Extended commands. The paragraphs below de- scribe their functions.
PTZ commands will always have B0 of word 4 set to zero. The remainder of the format is as follows.
Word 3 B7 — Always Zero (was camera on, auto scan) B6 — Camera On (was Coaxitron usage only) B5 — Auto Scan On (was Coaxitron only) B4 — Camera On, Camera Off (was auto scan, manual scan) B3 — Iris Close B2 — Iris Open B1 — Focus Near B0 — Focus Far
Word 4 B7 — Always Zero B6 — Zoom Wide B5 — Zoom Tele B4 — Down B3 — Up B2 — Left B1 — Right B0 — Always Zero for PTZ command
Word 5 Pan speed with values 0 to 0x3F and 0xx40 (Pan Turbo)
Word 6 Tilt speed with values 0 to 0x3F

Extended commands will always have B0 of Word 4 set to 1. The numbers below are in hexadecimal format.
Command Word 3 Word 4 Word 5 Word 6
Set preset XX 00 03 00 01 to 20
Clear preset XX 00 05 00 01 to 20
Go to preset XX 00 07 00 01 to 20
180 Flip preset 00 07 00 21
Zero pan position 00 07 00 22
Set aux XX 00 09 00 01 to 08
Clear aux XX 00 0B 00 01 to 08
Remote Reset 00 0F 00 00
Pat. Start Point 00 1F 00 00
Pat. Stop Point 00 21 00 00
Run Pattern 00 23 00 00
Zoom Lens speed 00 25 00 00 to 03
Focus Lens speed 00 27 00 00 to 03
The receiver will respond with an ACK (0XA2).

Table C. Circuit Board Parts List
Model CPU Board Video Board Power Board Backplane
DRD08A11 CPU08A11ASSY PCB8500101ASSY PCB8500130ASSY PCB8500150ASSY DRD08D11 CPU08D11ASSY PCB8500130ASSY PCB8500151ASSY DRD08P11 CPU08P11ASSY PCB8500130ASSY PCB8500151ASSY DRD08A21 CPU08A21ASSY PCB8500100ASSY PCB8500130ASSY PCB8500150ASSY DRD08D21 CPU08D21ASSY PCB8500130ASSY PCB8500151ASSY DRD08P21 CPU08P21ASSY PCB8500130ASSY PCB8500151ASSY DRD08A22 CPU08A22ASSY PCB8500100ASSY PCB8500140ASSY PCB8500150ASSY DRD08D22 CPU08D22ASSY PCB8500140ASSY PCB8500151ASSY DRD08P22 CPU08P22ASSY PCB8500140ASSY PCB8500151ASSY
DRD14A11 CPU14A11ASSY PCB8500101ASSY PCB8500130ASSY PCB8500150ASSY DRD14D11 CPU14D11ASSY PCB8500130ASSY PCB8500151ASSY DRD14P11 CPU14P11ASSY PCB8500130ASSY PCB8500151ASSY DRD14A12 CPU14A12ASSY PCB8500101ASSY PCB8500140ASSY PCB8500150ASSY DRD14D12 CPU14D12ASSY PCB8500140ASSY PCB8500151ASSY DRD14P12 CPU14P12ASSY PCB8500140ASSY PCB8500151ASSY DRD14A21 CPU14A21ASSY PCB8500100ASSY PCB8500130ASSY PCB8500150ASSY DRD14D21 CPU14D21ASSY PCB8500130ASSY PCB8500151ASSY DRD14P21 CPU14P21ASSY PCB8500130ASSY PCB8500151ASSY DRD14A22 CPU14A22ASSY PCB8500100ASSY PCB8500140ASSY PCB8500150ASSY DRD14D22 CPU14D22ASSY PCB8500140ASSY PCB8500151ASSY DRD14P22 CPU14P22ASSY PCB8500140ASSY PCB8500151ASSY

DC Stepper Motor Dome Drive: Pan — 32 vA Tilt — 32 vA Pan/Tilt — 48 vA Idle — 15 vA
(Design and product specifications subject to change without notice.)
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
Maximum Input Power

NOTE: This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interfer- ence at his own expense.

RETURNS In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge. Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below. If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699 If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following: If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco.
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
© Copyright 1999, Pelco. All rights reserved.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.