Instruction/ maintenance manual of the product C332M-D Pelco
Go to page of 16
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel (1-559) 292-1981 or FAX (1-5.
2 Pelco Manual C332M-D (10/98) REVISION HISTOR Y Manual # Date Comments C332M 9/89 Original version. C332M-A 10/91 Rev . A. Re vised to include model PT573-24R/HB. C332M-B 5/95 Rev . B . Section 4.4, Connector Assembly , re vised. Figures 7-9 revised.
Pelco Manual C332M-D (10/98) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser ved.
4 Pelco Manual C332M-D (10/98) 2.0 DESCRIPTION The PT573R and the PT573-24R are medium duty , indoor/outdoor pan/tilts de- signed f or V330APT retrofit applications. Both units feature rugged worm gear final drives to minimize bac klash and prev ent wind dr ift, and are fully adjustable f or wear .
Pelco Manual C332M-D (10/98) 5 NOTE: When mounting the pan/ tilt outdoors in the inv er ted position (base up), R TV silicone sealant, such as Dow Corning T ype 732 or equivalent, should be applied to the areas indicated in Figure 1.
6 Pelco Manual C332M-D (10/98) REQUIRES EXTERNAL POWER SUPPL Y Ta b le A. Requirements to Wire P ower to P an and Tilt Motors Model Wire Size Maximum Distance "A" Maximum Distance "B" Maximum Distance "B" (A WG) (5 Conductors*) (6 Conductors**) PT573R 20 5,800 ft (1,768 m)*** 1,045 ft (318.
Pelco Manual C332M-D (10/98) 7 Figure 2. Connector Assembly 3.3.1 Mating Connector Assembly To assemb le the mating connectors, ref er to Figure 2 and perform the f ollowing steps. The instructions that follo w apply to all AMP style connectors regardless of pin size or pin number .
8 Pelco Manual C332M-D (10/98) T TO FRAME SCAN CIRCUIT BOARD 4 13 14 11 12 2 10 3 7 P1 VIO RED BLU BRN/W ORG YEL BRN GRN 75W M2 C2 C3 S3 S4 S2 S1 BLU/W C1 M1 AU TO LEFT RIGHT COM UP DOWN COM GND AC NEUT 120 V A C 8 6 5 1 2 3 4 12 15 16 Figure 3.
Pelco Manual C332M-D (10/98) 9 NO TE: CO VER PLA TE IS NOT SHO WN. 3.4 LIMIT STOP ADJUSTMENTS To set pan/tilt limit stops , perf orm the following steps . Ref er to Figure 4. 1. Loosen the pan limit stops. 2. T urn the control unit on. Pan the unit to the right until the desired right pan limit is reached.
10 Pelco Manual C332M-D (10/98) Figure 5. Fr ame Scan Adjustment Location 3.5 FRAME SCAN ADJUSTMENT Fr ame scan duration is set at the factory for appro ximately four seconds . Y ou can adjust the scan duration to operate between tw o and nine seconds.
Pelco Manual C332M-D (10/98) 11 4.0 OPERA TION Refer to the manual for your control equipment for operating the pan/tilt..
12 Pelco Manual C332M-D (10/98) 5.0 TROUBLESHOOTING Some common problems encountered with pan/tilt systems include mis wir ing, over- loading, and not using the units for the correct application. If the pan/tilt unit fails to operate, do the f ollowing: 1.
Pelco Manual C332M-D (10/98) 13 6.0 MAINTENANCE Inspect the pan/tilt unit ev ery six months to ensure trouble-free operation and an e xtended product lif e. Harsh environments and/or continuous motion applications may require more frequent maintenance .
14 Pelco Manual C332M-D (10/98) 7.0 SPECIFICA TIONS GENERAL Construction: Aluminum plate, all internal par ts corrosion protected Dimensions: See Figure 7 Environment: Indoor/outdoor T emperature: -10 ° F to 140 ° F (-23 ° to 60 ° C) W eight Unit: 22 lb (9.
Pelco Manual C332M-D (10/98) 15 Connectors: Amp CPC type, mate supplied Motors: Two-phase induction type, continuous duty, instantaneous reversing Limit Switches: Pan and tilt – 5 amp, 10 million cycle rating (external adjust- ment) Conductor Requirements: 6 (7 if two wires are used for motor common) plus ground, unshielded Figure 7.
16 Pelco Manual C332M-D (10/98) 8.0 WARRANTY AND RETURN INFORMA TION W ARRANTY P elco will repair or replace , without charge, any merchandise prov ed defectiv e in material or wor kman- ship for a period of one year after the date of shipment.
An important point after buying a device Pelco C332M-D (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco C332M-D yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco C332M-D - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco C332M-D you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco C332M-D will certainly help you make a decision on the purchase.
If you already are a holder of Pelco C332M-D, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco C332M-D.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco C332M-D. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco C332M-D along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center