® 2500 Software Installation and Release Notes
Intelligent Switching Software Version 8.1.2
Part No.10005340 Published March 1999

3Com Corporation 5400 Bayfront Plaza Santa Clara, California 95052-8145
Copyright © 1999, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms or conditions of merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license agreement included with the product as a separate document, in the hardcopy documentation, or on the removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy, please contact 3Com and a copy will be provided to you.
If you are a United States government agency, then this documentation and the software described herein are provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense. Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable. You agree not to remove or deface any portion of any legend provided on any licensed program or documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not be registered in other countries.
3Com, the 3Com logo, CoreBuilder, LANplex, and Transcend are registered trademarks of 3Com Corporation. 3Com Facts is a service mark of 3Com Corporation.
DEC and PATHWORKS are registered trademarks of Compaq Computer Corporation. AIX, AT, IBM, NetView, and OS/2 are registered trademarks of International Business Machines Corporation. Microsoft, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. Sun and SunNet Manager are trademarks of Sun MicroSystems, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively through X/Open Company, Ltd.
All other company and product names may be trademarks of the respective companies with which they are associated.


COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
Overview These release notes describe CoreBuilder® 2500 Intelligent Switching software, version 8.1.2, from 3Com Corporation, dated February 19, 1999. This release supersedes LANplex® 2500 Intelligent Switching software, version 8.1.1, dated December 20, 1996.
In mid-1997, 3Com changed the name of the LANplex 2500 switch to the CoreBuilder 2500 switch. In version 8.1.2, however, the LANplex name and related abbreviations, such as lp and lpx, remain in the filenames and displays on the Administration Console.
These release notes use the CoreBuilder name. If applicable for your system, substitute LANplex for CoreBuilder throughout these release notes.
Before You Start Before you install Intelligent Switching software version 8.1.2 on your system, be sure to read this document in its entirety so that you understand the release features, system issues, known problems, supported configurations, and the software installation procedure.
You can load Intelligent Switching software version 8.1.2 on any LANplex 2500 or CoreBuilder 2500 system. Before you upgrade a system, read “Upgrade Considerations” on page 11 for important information and cautions.

8 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
Intelligent Switching software version 8.1.2 is a maintenance release that includes several patches (bug fixes). Table 1 lists the patch numbers and descriptions.
Table 1 Patch Descriptions

About Software Version 8.1.2 9
Table 1 Patch Descriptions (continued)

10 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
System Issues The following system issues have been identified for software version 8.1.2:
I When a ping is initiated from the CoreBuilder 2500 system and is destined to an ATM device that has a specific ATM adapter card, multiple pings are required before communication is initiated. This situation arises because of the amount of time required for the adapter card to resolve ATM ARP.
I An ATM LEC cannot be configured as the backbone port in Express Switching mode.
I After you set a system baseline, ATM LEC bridge statistics are incorrect.
I You cannot set the ipDefaultTTL MIB variable.
I When the ILMI autoconfiguration option is enabled on a CoreBuilder 7000 switch, it could take several minutes for a LEC configured on a CoreBuilder 2500 to join an emulated LAN.
I Packet filters can access data only through byte 64 in the packet.
I Roving Analysis frames that are sent over a remote Fast Ethernet connection are truncated if greater than 1495 bytes.
I Roving analysis is not supported on a system that has an ATM module installed in the chassis.
I Remote roving analysis is not supported over a Fast Ethernet connection that has the Spanning Tree Protocol enabled.
I Before you enable Express Switching mode, disable the backbone port. Then, after you enable Express Switching mode, reenable the backbone port.
I The system cannot route FDDI multicast frames that are larger than 1500 bytes (that is, frames that require fragmentation).
I The FCS error statistics field reports inaccurate values for Fast Ethernet ports.

There are three primary upgrade considerations:
I Once you install software version 7.0.0 or higher in a system that uses a revision 8.0 motherboard, you can never install software versions previous to version 7.0.0 in the future. To see if you have a revision 8.0 motherboard in your system, enter system display at the top level of the Administration Console. The first line of the display shows the product name and, in parentheses, the revision number of the motherboard.
I If you are upgrading from a release prior to version 7.0.0, be aware that the menu item ip forwarding was changed to ip routing at version 7.0.0. If you have created automated scripts that include ip forwarding, edit them to reflect this command change.
I If you are upgrading from a release prior to version 8.1.1, be aware that the parameter broadcast address in the IP interface definition procedure was changed to advertisement address(es) at version 8.1.1. If you have created automated scripts that include broadcast address, edit them to reflect this command change.
Each CoreBuilder 2500 chassis features two slots for low-speed modules (Ethernet) and two slots for high-speed modules (ATM, FDDI, or Fast Ethernet). At this release, however, the system supports only one ATM module per chassis.
In addition, restrictions apply to certain configurations that mix one ATM module with two older Ethernet 10BASE-FL modules (3C201400; no longer orderable). The combination of these three modules causes certain systems to draw excessive power and eventually fail. Whether your system could be affected by this module-combination problem depends on the revision level of the system motherboard.
You can order a newer version of the 10BASE-FL module (3C201400A). The configuration restrictions described in this section do not apply to this newer version of the 10BASE-FL module.
To determine the revision level of your system motherboard, enter system display at the top level of the Administration Console. The first line of the display shows the product name and, in parentheses, the revision number of the motherboard.
System Issues 11

12 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
Table 2 outlines the configuration restrictions.
Table 2 Physical Configuration Limitations
* This system configuration would be supported if you replace both of the older 10BASE-FL modules (3C201400) with the newer 10BASE-FL modules (3C201400A).

During system power on, Intelligent Switching software version 8.1.1 or later can detect the unsupported configurations that are outlined in Table 2. If the system detects an unsupported configuration, it does not boot up normally and initiates a critical error condition, as indicated by these symptoms:
I All LEDs on the system light.
I The Config LED flashes to indicate the critical error.
I The following error message appears:
FATAL Error
Option Module Configuration Not Supported. Illegal Combination of Adapter Cards
A similar error message appears if a newer Ethernet 10BASE-FL module (3C201400A) is present but is not functioning properly:
An Overcurrent Condition Has Occurred For The Adapter Card In Slot - 3 or 4 Please Remove This Adapter Card and Contact 3Com Technical Support.
System Issues 13

14 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
Most functionality in Intelligent Switching software version 8.1.2 is described in the documentation titles that are listed in Table 3.
Table 3 Customer Documentation*
CoreBuilder 2500 Getting Started Guide 801-00376-000
CoreBuilder 2500 Operation Guide 801-00375-000
CoreBuilder 2500 Administration Console User Guide 801-00374-000
* If you ordered a system that had Intelligent Switching software version 8.1.2 installed, then you also received a Documentation CD-ROM that contains online versions of these documents. If you are upgrading an existing system to version 8.1.2 and want to download the latest documentation, visit the 3Com Web site: www.3com.com
Other functionality in version 8.1.2 is described in “About Software Version 8.1.2” earlier in these release notes, as well as in Appendix A and Appendix B:
I Appendix A briefly describes the new features that were included in Intelligent Switching software version 8.1.1.
I Appendix B describes how to administer ATM. ATM is mentioned in Appendix A and described fully in Appendix B.
Some titles of documentation that are shipped with the CoreBuilder 2500 system use the LANplex name instead of the CoreBuilder name.
Title Part Number

Software Installation Procedure 15
Use this section in either of these cases:
I If these Intelligent Switching version 8.1.2 release notes are included in your system packaging, then version 8.1.2 is already installed on your system. Use this “Software Installation Procedure” section and the Software CD-ROM only if you need to reinstall the software later.
I If you are upgrading an existing system to Intelligent Switching software version 8.1.2, read through this entire “Software Installation Procedure” section at least once before you start the installation process.
Intelligent Switching software version 8.1.2 includes the following directory and file structure:
Filter Builder The Software CD-ROM also includes the Filter Builder utility, which you can use to develop and test packet filters for the CoreBuilder 2500 system. You load Filter Builder software on a PC, not on the system. See the LAN Switching Tools Filter Builder Getting Started Guide on the Documentation CD-ROM for more information about installing and using Filter Builder.
3Com Web Site You can also obtain Intelligent Switching software version 8.1.2 from the 3Com Web site. For easy downloading, all software files are compressed into one file. To locate this file, begin from the following URL: http://support.3com.com/software/switches.htm

16 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
To install CoreBuilder 2500 Intelligent Switching software version 8.1.2, follow these general steps, which are explained in greater detail in the indicated sections:
1 Copy the software files from the Software CD-ROM or download the software files from the 3Com Web Site to the hard disk of a host device.
See “Copying Software to a Hard Disk” for detailed instructions.
2 Prepare the system and the host device.
See “Preinstallation Tasks” for detailed instructions.
3 Install the diagnostic software file and system software files onto the CoreBuilder 2500 system by retrieving the files from the host device.
See “Installing the Diagnostic Software” and “Installing the System Software” for detailed instructions.
You can update software on the system while it is operating in a network. The system continues to forward traffic during the installation, except when the system is rebooting.
Because you cannot directly load Intelligent Switching software version 8.1.2 from the Software CD-ROM or the 3Com Web site onto your system, you use an interim host device to transfer software files to your system.
Prerequisites for the host device:
I Must be able to function as an FTP server
I Must use a UNIX, Windows 95, or Windows NT operating system
To copy the software to a host device, follow these steps:
1 Either:
a Copy the software files from the Intelligent Switching version 8.1.2 Software CD-ROM to the hard disk of the selected host device.
a Download the compressed file from the 3Com Web Site to the hard disk of the selected host device. Begin with the following URL: http://support.3com.com/software/switches.htm
b Decompress the file on the host device to reveal the individual
software files.

Software Installation Procedure 17
2 Because you need it later in the procedure, write down the exact pathname, using exact letter case, for the location of each software file on the host device.
If you copy files from one host device to another host device using the file transfer protocol (FTP), be aware that the case of the letters in the software filenames may change during the transfer.
3 Proceed to “Preinstallation Tasks” next.
Preinstallation Tasks To ensure that the system and the host device are ready to continue with the procedure, follow these steps:
1 Using the ip ping command, verify that the CoreBuilder 2500 system can reach the host computer to which you copied the updated software.
See the CoreBuilder 2500 Administration Console User Guide for more information about the ip ping command.
2 Verify that the host device has FTP server software running on it.
3 Using the system nvData save command, save your system’s NVRAM configuration data.
See the CoreBuilder 2500 Administration Console User Guide for more information about the system nvData save command.
4 Proceed to “Installing the Diagnostic Software” next.

18 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
The diagnostic software runs important internal tests at system power up. To update the diagnostic software on the system, follow these steps:
CAUTION: If you are performing this upgrade process from a remote host (for example, using a modem connection or telnet session), do not disconnect your session to the CoreBuilder 2500 system while the software update is in progress, or the file may become corrupted. If your session is disconnected, do not reboot the system. Instead, log in to the system again and restart the entire software installation procedure.
1 To ensure that no other administrative sessions can occur during the update process, lock the Administration Console:
a From the top level of the Administration Console, enter:
2 To begin loading the diagnostic software, enter the following command from the top level of the Administration Console:
The system prompts you for several items of information.
Press Return at any prompt to accept the default value that is shown in brackets.
3 At the Host IP address prompt, enter the IP address of the host device from which you are retrieving the diagnostic software.
4 At the Install file pathname prompt, enter the complete path and filename.
Paths and filenames are case-sensitive. Be sure to type them exactly as shown on the hard disk of the host device.
For an MS-DOS host, you must precede the full path with a forward slash (/). Example: /c:\3com\cb2500\lpx2000s
5 At the User name prompt, enter your user name.

Software Installation Procedure 19
6 At the Password prompt, enter your password. The field does not display the characters that you enter.
After you enter your password, the system begins to retrieve the file from the host device.
When the installation is complete, the system returns you to the top level of the Administration Console.
Example Host IP address [192.9.200.14]: 192.9.200.96 Install file pathname[/usr/cb2500/lpx2000s]: User name: scottco Password: Programming flash memory block 1 of 2... Programming flash memory block 2 of 2 ... Installation complete.
7 To activate the newly loaded diagnostic software, reboot the system by entering the following command from the top level of the Administration Console:
After the reboot, the system retains the user-configurable nonvolatile data.
8 Log in to the system and proceed to “Installing the System Software” next.

20 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
The system software is organized in two files: an expander file (lpexpand) and a compressed image file (lp2500c). The expander file is a utility that expands the compressed image and moves it from flash memory into random access memory on the system.
To install system software, you complete these four tasks:
I Reboot the system
I Retrieve the compressed image again: lp2500c
Detailed instructions for each task are provided next.
To load the expander file onto the CoreBuilder 2500 system, follow these steps:
1 To ensure that no other administrative sessions can occur during the update process, lock the Administration Console:
a From the top level of the Administration Console, enter:
If you completed step 1 in “Installing the Diagnostic Software” earlier in these release notes, the consoleLock is already set to on.

Software Installation Procedure 21
2 From the top level of the Administration Console, enter:
The system prompts you for several items of information.
Press Return at any prompt to accept the default value that is shown in brackets.
3 At the Host IP address prompt, enter the IP address of the host device from which you are retrieving the expander file.
4 At the Install file pathname prompt, enter the complete path and filename.
Paths and filenames are case-sensitive. Be sure to type them exactly as shown on the hard disk of the host device.
For an MS-DOS host, you must precede the full path with a forward slash (/). Example: /c:\3com\cb2500\lpexpand
5 At the User name prompt, enter your user name.
6 At the Password prompt, enter your password. The field does not display the characters that you enter.
After you enter your password, the system begins to retrieve the file from the host device.
When the installation is complete, the system returns you to the top level of the Administration Console. Do not reboot the system.
Example Host IP address [192.9.200.14]: 192.9.200.96 Install file pathname[/usr/cb2500/lpexpand]: User name: scottco Password: Programming flash memory block 1 of 1... Installation complete.
7 Proceed to “Loading the Compressed Image” next.

22 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
To load the compressed image file onto the CoreBuilder 2500 system, follow these steps:
1 From the top level of the Administration Console, enter:
The system prompts you for several items of information.
Press Return at any prompt to accept the default value that is shown in brackets.
2 At the Host IP address prompt, enter the IP address of the host device from which you are retrieving the compressed image.
3 At the Install file pathname prompt, enter the complete path and filename.
Paths and filenames are case-sensitive. Be sure to type them exactly as shown on the hard disk of the host device.
For an MS-DOS host, you must precede the full path with a forward slash (/). Example: /c:\3com\cb2500\lp2500c
4 At the User name prompt, enter your user name.
5 At the Password prompt, enter your password. The field does not display the characters that you enter.
After you enter your password, the system begins to retrieve the file from the host device.
When the installation is complete, the system returns you to the top level of the Administration Console.

Software Installation Procedure 23
Example Host IP address [192.9.200.14]: 192.9.200.96 Install file pathname[/usr/cb2500/lp2500c]: User name: scottco Password: Programming flash memory block 1 of 15... Programming flash memory block 2 of 15... Programming flash memory block 3 of 15 Programming flash memory block 15 of 15... Installation complete.
6 Proceed to “Rebooting the System” next.
To reboot your system, follow these steps:
1 From the top level of the Administration Console, enter:
2 When the reboot is complete, log in to the system and proceed to “Reloading the Compressed Image” next.
You must load the compresed image file again. Follow these steps:
1 From the top level of the Administration Console, enter:
The system prompts you for several items of information.
Press Return at any prompt to accept the default value that is shown in brackets.
2 At the Host IP address prompt, enter the IP address of the host device from which you are retrieving the compressed image.
3 At the Install file pathname prompt, enter the complete path and filename.
Paths and filenames are case-sensitive. Be sure to type them exactly as shown on the hard disk of the host device.
For an MS-DOS host, you must precede the full path with a forward slash (/). Example: /c:\3com\cb2500\lp2500c
4 At the User name prompt, enter your user name.

24 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
5 At the Password prompt, enter your password. The field does not display the characters that you enter.
After you enter your password, the system begins to retrieve the file from the host device.
When the installation is complete, the system returns you to the top level of the Administration Console. You do not need to reboot the system.
Example Host IP address [192.9.200.14]: 192.9.200.96 Install file pathname[/usr/cb2500/lp2500c]: User name: scottco Password: Programming flash memory block 1 of 15... Programming flash memory block 2 of 15... Programming flash memory block 3 of 15 Programming flash memory block 15 of 15... Installation complete.
6 You must now reset the password for the administer access level. Follow these steps:
This step activates patch number 32 in this release. See “About Software Version 8.1.2” earlier in these release notes for patch descriptions.
a From the top level of the Administration Console, enter:
You are prompted for an access level to change.
c At the prompt for your old password, enter the old password.
d You are prompted for a new password. Enter a new password.
e At the prompt, enter your new password again.
7 Unlock the Administration Console.
a From the top level of the Administration Console, enter:
You have completed the installation procedure for Intelligent Switching software version 8.1.2.
b Enter administer · b Enter off

SNMP MIB Files 25
SNMP MIB Files Table 4 lists the public and private SNMP MIB files that are included in CoreBuilder 2500 Intelligent Switching software version 8.1.2 as ASN.1 files.
These MIB files are unchanged from those that were included with Intelligent Switching software version 8.1.1.
Table 4 Supported MIBs
Public MIBs Private MIBs
ATM MIB - RFC 1695 (atm.mib) LANplex Optional FDDI MIB v1.2.1 (lpOpFddi.mib)
ATM MIB, af-lane-1129.001 (les.mib) LANplex Systems MIB v1.3 (lp.mib)
Bridge MIB - RFC 1493 (bridge.mib)
Ethernet MIB - RFC 1398 (ethernet.mib)
FDDI SMT v7.3 - RFC 1512 (fddiSmt7.mib)
Interface MIB - RFC 1573 (if.mib)
LEC MIB, af-lane-0044.00 (lec.mib)
MIB II - RFC 1213 (mib2.mib)
Compiler Support 3Com provides ASN.1 MIB files for each of the MIB compilers that are listed in this section. Any warnings or exceptions related to a compiler are listed with it.
I SMIC (version 1.0.9)
I MOSY (version 7.1)
For the MIB file lpOpFddi.mib, the MOSY compiler reports warnings for counter names that do not end in “s”. These reports have no effect on the output produced by the MOSY compiler.
I HP Openview (version 3.1)

26 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2
I mib2schema (with SunNet Manager version 2.0)
The MIB file fddiSmt7.mib produces the following warning messages when compiled using mib2schema:
Translating
Translation Complete.
Schema file in “fddiSmt7.mib.schema”
Oid file in “fddiSmt7.mib.oid”
These warning messages have no effect on the ability of SunNet Manager to use the schema file generated with SunNet Manager version 2.0 or later.
Release History Table 5 provides a brief release history for the CoreBuilder 2500 Intelligent Switching software.
Table 5 Release Descriptions
8.1.2 Maintenance release that includes various patches (bug fixes) as described in these release notes
8.1.1 New features:
I Support for ATM module
I IP interface definition change
I System Uptime menu added
I Several MIB updates
I Per-port removal from Spanning Tree
I Telnet timeout change
7.0.1 Maintenance release that corrected problems with the third-party management processor that is used in the system
fddimibMACSMTIndex · fddimibMACIndex · Version Description

Table 5 Release Descriptions (continued)
7.0.0 New features:
I Support for the Fast Ethernet module
I Support for the unterminated BNC module
I Support for IP multicast
I Telnet and rlogin sessions now terminate after a user-specified time interval
I Configurable Spanning Tree Protocol (STP) group address
I Menu item change (ip forwarding now ip routing)
I Support for 64 IP static routes
I Ethernet ports configurable as Express Switching ports
5.1.0 Maintenance release that included various patches (bug fixes)
5.0.0 New features:
4.3.0 New features:
I IPX Snap translation
4.2.0 New features:
I Support for the AUI and terminated BNC modules
4.0.1 Maintenance release that included various patches (bug fixes)
4.0.0 First release of LANplex 2500 system software

28 COREBUILDER 2500 INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.2

NEW FEATURES IN INTELLIGENT SWITCHING SOFTWARE VERSION 8.1.1
This appendix describes the new features, menu changes, and corrections that were introduced in Intelligent Switching Software version 8.1.1 and remain in version 8.1.2.
Use this appendix as an addendum to the documentation titles that are listed in Table 3 on page 14 earlier in these release notes.
New Features The following features or changes, which were introduced in version 8.1.1, are described briefly in the next few sections:
I Support for the ATM Module (more fully described in Appendix B)
I Parameter Change in Interface Definition Procedure
I Defining an IP Interface
I Field Added to the Interface Display
I New System Uptime Menu
I New and Updated MIBs
I Removing STP on a Per Port Basis
I Telnet Timeout Interval Changed

Intelligent Switching software version 8.1.1 supports the CoreBuilder 2500 ATM Module, which provides a single OC-3 155 Mbps interface (multimode fiber) into a high-speed slot.
Physical Configuration
Each CoreBuilder 2500 chassis has two slots for high-speed modules (100 Mbps or higher) and two slots for low-speed modules. You can install only one ATM module per chassis. See “Restrictions with ATM and 10BASE-FL Modules” on page 11 for details.
The CoreBuilder 2500 ATM Module is designed to be fully interoperable with other 3Com ATM switches, as well as with other switches that comply with industry standards (UNI 3.0 and LANE 1.0).
The ATM module supports these features:
I UNI 3.0 signaling
I LAN Emulation 1.0 (LEC support) — 2 Emulated LANs
I Dynamic configuration of Emulated LANs (ELANs)
I A maximum of 128 Virtual Connections (VCs) per system
I Management:
I UME Address registration
For detailed information about administering the ATM module and related software commands, see Appendix B in these release notes.
The parameter broadcast address in the IP interface definition procedures has been changed to advertisement address(es), primarily to support nonbroadcast networks, such as ATM.
Procedure
Previously, a broadcast address was configured for each IP interface. The router used this IP address as the destination address for advertisements, such as RIP updates. You may now enter one or more addresses, and the router sends advertisements to each of these addresses. There is no restriction on the addresses. They may be broadcast addresses, individual addresses, or any combination. Separate multiple addresses with commas (,).

When you define an IP interface, you now specify several IP interface characteristics.
1 From the top level of the Administration Console, enter:
The system prompts you for the interface parameters.
To accept the value in brackets, press Return at the prompt.
2 Enter the IP address of the interface.
3 Enter the subnet mask of the network to which the interface is to be connected.
4 Enter the cost value of the interface.
5 Enter the type of IP interface: management.
Example Enter IP address: 158.101.1.1 Enter subnet mask [255.255.0.0]: 255.255.255.0 Enter cost [1]: 1 Enter interface type (management) [management]: management Enter advertisement address(es)[158.101.1.255]: 158.101.1.255
If you physically change the configuration of your system after you define IP interfaces, the ports designated for those interfaces may no longer be valid. You may want to reconfigure your interfaces.
You can display both summary and detailed information about all IP interfaces that are configured for the system. The detail display contains all the summary information as well as information about the advertisement address, PVCs, and VLANs.
1 To display IP interface information, enter one of the following command strings from the top-level menu of the Administration Console: ip interface summary or ip interface detail
2 Enter specific interface index numbers or all.
New Features 31

A new field, State, has been added to the interface display table, allowing you to view the state of all interfaces configured for each switching module in the system.
The interface state is determined based on the state of all ports associated with the interface. For IP, the state displayed is either Up or Down:
I The interface state is displayed as Down if no port in the defined interface, including those in overlapping subnetworks, has established link status. Link status is not established for FDDI DAS ports when neither the A nor the B port has established link status.
I The interface state is displayed as Up if one or more ports in the defined interface, including those in overlapping subnetworks, have established link status.
As the interface state changes, transitions are reflected in the corresponding tables for all directly connected and associated routes.
For IP transitions, all routes that are associated with the interface time out in the same manner as do learned routes that are not updated.
If link status is transitioned, previously defined configurations, such as static routes, do not have to be redefined.
A menu option was added so that you can display the time — in minutes, hours, and days — since the last system reboot occurred.
To display system upTime, from the top level of the Administration Console, enter system upTime

At version 8.1.1, LANplex MIB support was added for:
I File transfer of Flash and NVRAM images
I Enhanced FDDI MAC and port configuration
I SNMP community string configuration
I Control panel access lock
I Remote console session lock
I Console password configuration
I Date and time configuration
I FDDI backplane station mode configuration
At version 8.1.1, support for the Interface MIB (if.mib) was added. This MIB supports the following objects:
At version 8.1.1, support for the ATM MIB (atm.mib) was added.
Beginning in version 8.1.1, you may remove ports from the Spanning Tree operation on a per-port basis. Ports removed from Spanning Tree (STP) do not participate in the STP operation but continue to forward data. Previously, ports could be enabled or disabled. For more information on administering STP bridge port parameters, see the CoreBuilder 2500 Administration Console User Guide.
Telnet Timeout Interval Changed
Beginning in version 8.1.1, you can configure the telnet timeout interval to a number between 1 and 60 minutes. Previously, this interval could only be configured to a number between 30 and 60 minutes.


B
This appendix describes how to administer asynchronous transfer mode (ATM) on a LANplex® 2500 or CoreBuilder® 2500 system. It covers the following topics:
I ATM in Your Network
I Before You Configure ATM
I Administering UNI Management Entities
I Administering ATM Ports
Before you add an ATM module to your system, see “Restrictions with ATM and 10BASE-FL Modules” on page 11 for details.
I LAN Emulation

ATM in Your Network
ATM architecture differs fundamentally from IEEE 802.x technology. IEEE 802.x LANs, which are limited to FDDI, Ethernet, and token ring, are connectionless and use the Media Access Control (MAC) addresses in each packet to communicate to end-stations. ATM is connection-oriented and uses an circuit identifier, called a virtual channel identifier, to exchange data between two ATM stations over previously established virtual channel connection (VCC).
To forward data over an ATM interface in an existing network, two methods are provided to adapt existing network layer protocols to the connection-oriented paradigm of ATM:
I LAN Emulation (LANE) — Supports transparent translation of higher level protocols, such as IP, IPX, and AppleTalk protocols. LANE also supports broadcast and multicast addressing.
I Classical IP over ATM — Supports transparent translation of IP only over ATM, and does not support broadcast or multicast addressing.
Classical IP is supported only in CoreBuilder 2500 Extended Switching Software, version 8.1.0 or later. Thus, it does not apply to Intelligent Switching Software version 8.1.2.

Before You Configure ATM 37
Before you configure ATM, follow these steps:
I Check the ATM link status.
I Verify that address registration is operational.
I Verify that signalling is operational.
To check the link status, follow these steps:
1 From the top level of the Administration Console, enter:
You are prompted for the number(s) of the UME that you want to display.
2 Enter the number(s) of the UME(s) or all.
Sample ATM UME display:
reqState state reqVpi connected connected 0
vpi reqVci vci 0 16 16
connCount discCount rxPdus 2 2 232
dropRxPdus txPdus 0 209
The state field should show connected. If the state field shows disconnected, there is a problem with the link. If this happens, check the cabling to ensure that the CoreBuilder 2500 system is correctly connected to the ATM switch.

Verifying Address
After you ensure that the link is connected, verify that the system is able to register addresses at both the network and the user sides of the UME Network Interface (UNI). Two addresses — one for LAN Emulation and one for Classical IP over ATM — are registered at the network side.
To verify registered addresses:
1 From the top level of the Administration Console, enter:
The system prompts you for the number(s) of the ATM ports that you want to list.
2 Enter the number(s) of the port(s) or all. Sample ATM UME list:
Select Atm port(s) (1-2|all) [1]:
Addresses registered at the network side UNI: 47-0005-80-ffe100-0000-f21a-200e-00803e1f6712-00 47-0005-80-ffe100-0000-f21a-200e-00803e1f6713-00

Before You Configure ATM 39
Verifying Signaling The ATM signaling protocol allows end-stations to establish, maintain, and clear ATM connections between end points with virtual connections (VCCs). Multiple virtual connections can exist on a physical link. There are two types of virtual connections: a virtual path and a virtual channel.
You can verify that signaling is operational by viewing the virtual connections — virtual path identifiers (VPIs) and virtual channel identifiers (VCIs) that the system has established.
To verify that signaling is operational, from the top level of the Administration Console, enter atm ports vcc list
Sample VCC list:
VPI/VCI status aalType lastChange
0/5 localUpEndToEndUnknown 5 1 min 0/16 localUpEndToEndUnknown 5 1 hr 37 mins 25 secs 3/381 localUpEndToEndUnknown 5 2 hrs 51 mins 40 secs 3/382 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs 3/383 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs 3/384 localUpEndToEndUnknown 5 2 hrs 51 mins 40 secs 3/385 localUpEndToEndUnknown 5 2 hrs 51 mins 42 secs 3/386 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs 3/387 localUpEndToEndUnknown 5 2 hrs 51 mins 42 secs 3/388 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs
In addition to newly defined VCCs, two additional VCCs are listed, which are reserved VPIs and VCIs used for signaling (VPI 0/VCI 5) and for the UME ILMI (VPI 0/VCI 16).

LAN Emulation LAN Emulation (LANE) provides unicast, multicast, and broadcast network behavior over connection-oriented ATM. An emulated LAN (ELAN) can consist of many LAN emulation clients (LECs). An ELAN consists of the following components:
I A Broadcast and Unknown Server (BUS) — Responsible for handling broadcast, multicast, and initial unicast frames sent from a LAN Emulation Client. Each ELAN contains only one BUS.
I A LAN Emulation Server (LES) — Responsible for registering and resolving MAC addresses to ATM addresses for LECs. Each ELAN contains only one LES.
I LAN Emulation Clients (LECs) — The end node from the perspective of the ATM network. It performs data forwarding, address resolution, and other control functions. Additionally, it maintains the LAN emulation software.
I A LAN Emulation Configuration Server (LECS) — The LECS provides configuration information about the ATM and LAN networks. It also provides the address of the LES to the LEC.
I You must define a LES and a BUS as part of an ELAN before you can define a LEC.
I You can configure the LES and the BUS on the same LEC or on different LECs.
You can create an 802.3 emulated LAN on ATM by defining the LAN’s servers (the BUS and the LES) and then configuring each LAN Emulation Client (LEC).
To create an emulated LAN, follow these steps:
1 Determine the location of the BUS and LES.
You can define the BUS and LES in any LEC on the network, or on an ATM switch, such as the 3Com CoreBuilder 7000 system.
2 Define the Broadcast and Unknown Server (BUS).
3 Define the LAN Emulation Server (LES).
4 Define the LAN Emulation Clients (LEC).

When configuring more than one LEC in a LANplex 2500 or CoreBuilder 2500 system, a bridge loop may be created. This possibility exists because the LANplex can bridge between all ports, including logical bridge ports (LECs). Because the Spanning Tree Protocol (STP) is off by default, we recommend following this procedure when you create multiple LECs with Intelligent Switching software:
1 After you define all LECs, at the Enable State prompt, enter enable
2 Enable STP. From the top level of the Administration Console, enter:
3 Reboot the system.
The system adds the LECs to the bridge table.
You can configure a LAN Emulation Client (LEC) to join an existing 802.3 emulated LAN by providing information about the LAN Emulation Server (LES) and the Broadcast and Unknown Server (BUS).
Emulated LAN
Defining LAN Emulation Clients
When you define a LAN Emulation Client, you give information necessary for a client to be included in the emulated LAN. A BUS and a LES must already be defined as part of the emulated LAN before you can define a client.
When the client attempts to join the emulated LAN, some of the configured information is carried along with the join request sent to the LES. The LES can alter this information. The client then has the option of accepting or rejecting any changes made by the LES. If the changes are accepted or if there are no changes, the client successfully joins the emulated LAN. Otherwise, the join fails.
To define a client:
1 From the top level of the Administration Console, enter:
2 Enter the number of the ATM port to which the client is attached.
You can attach only one client per port to the same emulated LAN.
LAN Emulation 41

3 Enter the LECS access type. Choices are lecs and manual.
If you choose LECS as your means of joining an ELAN, and another CoreBuilder system provides LES and BUS services, you must update the directly attached ATM switch LECS with the ELAN name and the corresponding LES address.
4 Enter the name of the emulated LAN to which you are adding the client, or press Return to choose the default ELAN shown in brackets. The ELAN name may contain a maximum of 32 characters.
5 Enter the maximum transmission unit (MTU), also known as maximum frame size. Choices are Unspecified, 1516, and 4544.
The system supports Unspecified Bit Rate (UBR) only.
All LECs within the same emulated LAN must have the same MTU size. Enter Unspecified to allow the LES to select an appropriate MTU size.
6 Enter enable for the enable state for the next reboot.
7 Repeat steps 1 through 6 to define other LECs.
8 Enable STP to eliminate potential bridge loops. From the top level of the Administration Console, enter:
9 Reboot to enable all newly defined LECs.
Sample procedure:
Select menu option (atm/lane/lec): define Select ATM port [1]: Enter LEC access type (lecs, manual) [lecs]: Enter Elan Name []: Elan_1 Enter Elan MTU Size (Unspecified,1516,4544) [Unspecified]: Enter Enable State for next reboot (disable, enable) [enable].
You must REBOOT to be able to enable a newly created LEC.
Reboot after you have added all newly created LECs.

From the Administration Console you can:
I Display summary or detailed information about emulated LAN clients
I Modify information for emulated LAN clients
I Define a client for inclusion in an emulated LAN
I Remove a client from the network
You can display a summary report or a detailed report of information about LAN Emulation Clients. The summary displays information about the location and state and the most important statistics about the client’s general activity. The detailed includes the summary information plus additional statistics.
To display information about a LAN Emulation Client:
1 From the top level of the Administration Console, enter:
atm lane detail
You are prompted for the number of a LEC.
2 Specify the number of the LAN Emulation Client about which you want information.
The information is displayed in the format you specified.
LAN Emulation 43 · or

Sample summary display for a LAN Emulation Client:
location bridgePort state Port 1 Port 10 init
maxArpRtryCt arpRespTime arpAfterCt 1 1 0
inArpReqs inArpRsps outBusUcDscrds 0 3 0
elanName elanType elan463_0 802.3
elanMtu lesAccessType connCompTime 1516 lecs 4
controlTime flushRspTime maxUnkFrmTim 120 4 1
pthSwtDlyTim vccTime topologyChgFlag 6 1200 0
fwdDelayTime ageTime inCtrls 15 300 34
outCtrls inDds outDds 4422 0 0
inBus outBus outArpReqs 0 0 3
outArpRsps macAddress 0 00-80-3e-20-9e-fd
busAddress 47-0000-00-000000-0000-0000-00aa-00c0da6001cf-00 · lesAddr 47-0000-00-000000-0000-0000-00aa-00c0da6001cf-00 · lecsAddr 00-0000-00-000000-0000-0000-0000-000000000000-00

Sample detail display for a LAN Emulation Client:
location bridgePort state Port 1 Port 10 init
requestedState configSource cfgMaxArpRtryCt enabled manual 1
maxArpRtryCt cfgArpRespTime arpRespTime 1 1 1
cfgMaxUnkFrmCt arpAfterCt inArpReqs 1 0 0
inArpRsps outBusUcDscrds 3 0
elanName cfgElanType elan463_0 802.3
elanType cfgElanMtu elanMtu 802.3 1516 1516
cfgLesAccessType lesAccessType cfgConnCompTime lecs lecs 4
connCompTime cfgCtrlTimer controlTime 4 120 120
cfgFlushRspTime flushRspTime maxUnkFrmTime 4 4 1
maxUnkFrmTim cfgPathSwDlyTime pthSwtDlyTim 1 6 6
cfgVccTime vccTime topologyChgFlag 1200 1200 0
cfgFwdDlyTime fwdDelayTime cfgAgeTime 15 15 300
ageTime inCtrls outCtrls 300 34 4271
inDds outDds inBus 0 0 0
outBus outArpReqs outArpRsps 0 3 0

Table 6 describes the attributes of the LAN Emulation Client displays. References to the ATM Forum Specification for LAN Emulation appear in parentheses following the parameter description.
Table 6 Fields in the LAN Emulation Client Displays
arpAfterCt Number of unknown frames after which the client sends an LE_ARP request
busAddress ATM address of Broadcast and Unknown Server
cfgAgeTime Requested maximum time that the client maintains an entry in its LE_ARP cache (C17)
cfgArpRespTime Requested maximum time (in seconds) that the client expects between an LE_ARP request and an LE_ARP response (C20)
cfgConnCompTime Requested time during which data or a READY_IND message is
expected from a calling party (C28)
cfgCtrlTimer Requested timeout period for request/response control frame interactions (C7)
cfgElanType Requested type of LAN to emulate (802.3)
cfgElanMtu Requested maximum frame size
cfgElanName Requested emulated LAN name
cfgflushRspTime Requested time limit for receiving an LE_FLUSH_RESPONSE after sending an LE_FLUSH_REQUEST (C21)
cfgFwdDlyTime Requested maximum time that the client maintains an entry for a nonlocal MAC address in its LE_ARP cache as long as the topologyChgFlag is true (C18)q
cfgLesAccessType Requested method for determining how to access the LAN Emulation Server
cfgLesAddr ATM address of requested LAN Emulation Server
cfgMaxArpRtryCt Requested maximum number of LE_ARP attempts
cfgMaxUnkFrmCt Requested maximum unknown frame count (C10)
cfgPathSwDlyTime Requested time since sending a frame to the BUS after which the client assumes that the frame has been discarded or delivered (C22)
cfgVccTime Requested time after which the client releases any data direct VCC that did not transmit or receive data frames (C12)
LesAccessType Current type of access to the LAN Emulation Server
lecState Current client machine state
location ATM port to which the client is connected
ElanMtu Current maximum frame size
ElanName Current emulated LAN name
ElanType Type of LAN currently emulated (802.3)
Parameter Description

Table 6 Fields in the LAN Emulation Client Displays (continued)
enabled Current management state of the client (disabled or enabled)
inArpReqs Number of LE_ARP requests received
inArpRsps Number of LE_ARP responses received
inBus Number of frames transmitted to the Broadcast and Unknown Server
inCtrls Number of control frames received
inDds Number of frames received on data direct circuits
lecAddress ATM address of client
LesAddr ATM address of current LAN Emulation Server
maxUnkFrmTime Requested time period during which the client will send no more than the maximum number of unknown frames to the Broadcast Unknown Server (BUS) for a given destination (C11)
outCtrls Number of control frames transmitted
outDds Number of frames transmitted on data direct circuits
outArpReqs Number of LE_ARP requests transmitted
outArpRsps Number of LE_ARP responses transmitted
outBus Number of frames received from the Broadcast and Unknown Server
outBusUcDscrds Number of unknown unicast frames thrown away by the Broadcast and Unknown Server
requestedState Requested management state of the client (disabled or enabled)
topologyChgFlag Boolean value indicating that the client is using Forward Delay Time rather than Aging Time to age nonlocal entries in its LE_ARP cache (C19)
LAN Emulation 47 · Parameter Description

Modifying Information About LAN Emulation Clients
To modify LAN Emulation Client parameters, follow these steps:
1 From the top level of the Administration Console, enter:
You are prompted for the parameter that you want to modify.
2 Enter the parameter.
You are prompted for the number(s) of the LEC(s) that you want to modify.
3 Select the number(s) of the LEC(s) or all.
You are prompted for the new value of the option that you selected.
4 Enter the new value.
If you modify the ELAN name in the LEC configuration, you must disable and then enable the LEC before the change takes effect.
To remove a client from the emulated LAN, follow these steps:
1 From the top level of the Administration Console, enter:
You are prompted for the number of the LEC to remove.
2 Specify the number of the LEC to remove.
You are prompted to confirm the deletion.
3 Enter y to confirm or n to cancel. If you enter y, the system reboots and deletes the specified LEC.
Sample procedure:
Select menu option (atm/lec): remove Select LEC(s) (1-3|all) [1]: 1 Delete LEC(s) resulting in system reboot?” (n,y) [y]: y

Administering UNI Management Entities 49
A User-to-Network Interface (UNI) Management Entity (UME) implements the management interface to the ATM network. Each ATM port has one UME, which manages the network prefix and address tables and provides access to the Interim Local Management Interface (ILMI) MIB.
Each CoreBuilder 2500 UME registers one address for LAN Emulation and one address for Classical IP over ATM with the switch port to which it is attached.
You can display information about each UME and configure its attributes.
When you display UME information for an ATM port, you display values for the connection state, the VPI (virtual path identifier), the VCI (virtual channel identifier), and other attributes.
To display UME information:
1 From the top level of the Administration Console, enter:
You are prompted to select an ATM port.
2 Enter the ATM port for which you want to display the UME information.
The UME information is displayed.
Sample display:
reqState state reqVpi connected disconnected 0
vpi reqVci vci 0 16 16
connCount discCount rxPdus 2 2 232
dropRxPdus txPdus 0 209

Table 7 describes the fields provided in the UNI Management Entity displays.
Table 7 Fields in the UME Display
connCount Number of times port has successfully connected since last reboot
discCount Number of times port has disconnected since last reboot
dropRxPdus Number of protocol data units (frames) received but not processed
reqState Requested connection state for management access and address registration (connected or disconnected)
reqVci Requested virtual channel identifier. This value takes effect after you disable and then enable the port.
reqVpi Requested Virtual Path Identifier. This value takes effect after you disable and then enable the port.
rxPdus Number of protocol data units (frames) received
txPdus Number of protocol data units (frames) transmitted.
state Current connection state for management access and address registration. Possible values:
I Connected — Address registration has been successfully completed
I Connecting — Circuit is up, but the port has not successfully completed address registration
I Disconnected — Either the reqState has been set to this state or the circuit is down
I Disconnecting — Address registration has been terminated but the circuit is still up
vci Current virtual channel identifier
vpi Current virtual path identifier
Attribute Description

Administering UNI Management Entities 51
You can list the registered network prefixes and addresses of any ATM port.
Addresses
To list prefixes and addresses:
1 From the top level of the Administration Console, enter:
You are prompted for an ATM port.
2 Select an ATM port.
The registered network prefixes and addresses are listed for the port that you requested.
Sample UME list:
Addresses registered at the network side UNI: 47-0005-80-ffe100-0000-f21a-200e-00803e1f6712-00 47-0005-80-ffe100-0000-f21a-200e-00803e1f6713-00
For each ATM port, you can set the connect state for management access and address registration.
To set the connect state:
1 From the top level of the Administration Console, enter:
You are prompted for an ATM port.
2 Enter the ATM port for which to set the state.
3 Enter the new value (connected or disconnected). The default is connected.

Setting the Virtual
For each ATM port, you can set the virtual path identifier (VPI) used by UME for the Interim Local Management Interface (ILMI). To set the VPI:
1 From the top level of the Administration Console, enter:
You are prompted for an ATM port.
2 Enter the ATM port for which you want to set the virtual path identifier.
3 Enter the new value for the VPI.
The new VPI takes effect after the port has been disabled and then enabled.
You can set the virtual channel identifier (VCI) used by UME for the Interim Local Management Interface (ILMI). To set the VCI:
1 From the top level of the Administration Console, enter:
You are prompted for an ATM port.
2 Enter the ATM port for which you want to set the virtual channel identifier.
3 Enter the new value for the VCI.
The new VCI takes effect after the port has been disabled and then enabled.

Administering ATM Ports 53
You can display summary or detailed reports, create labels, and list virtual channel connection (VCC) information for ATM ports.
You can display a summary of ATM port information or a detailed report. When you display a summary, you receive information about the port, including its label, status, and the most important statistics about general port activity and port errors. The detailed report includes the information in the summary plus additional port statistics, such as cells discarded.
To display information about ATM ports:
1 From the top level of the Administration Console, enter:
atm ports summary or atm ports detail
The port information is displayed in the format you specified.
Sample summary display:
status cfgVPCs cfgVCCs inService 2 10
bandWidth rxCells txCells 148608000 13467 13434
Sample detail display:
status cfgVPCs cfgVCCs inService 2 10
bandWidth rxCells txCells 148608000 13196 13163
ocdEvents hecErrors txCellDiscards 2 7 0
transType mediaType uniType sonet multiMode private
uniVersion tcAlarm maxVPCs 3.0 noTcAlarm 16
maxVCCs maxVPIbits maxVCIbits 1024 4 10
portLabel · lastChange 1 min · portLabel

Table 8 describes the fields in the port displays:
Table 8 Fields in the ATM Ports Displays
bandwidth Total bandwidth available for port (in bits per second)
cfgVPCx Current number of virtual path connections
cfgVCCs Current number of virtual channel connections
hecErrors Header Error Checksum count
lastChange Last time the link state of the port changed since the last reboot
linkStatus State of link
maxVCCs Maximum number of possible virtual channel connections
maxVPCs Maximum number of possible virtual path connections
maxVCIbits Maximum number of bits available to represent a Virtual Channel Identifier
maxVPIbits Maximum number of bits available to represent a Virtual Path Identifier
mediaType Type of physical connection media
ocdEvents Number of times an out-of-cell delineation was detected
operStatus Current state of port
portLabel Label for the physical port
reqStatus Requested state of port
rxCells Number of cells received
rxCellsDropped Number of cells received but thrown away
tcAlarm Transmission convergence alarm
transType Type of transmission sublayer
txCellDiscards Number of cells thrown out after attempting to transmit
txCells Number of cells transmitted
uniType Type of User-Network Interface (public or private)
uniVersion UNI specification implemented
Field Description

Administering ATM Ports 55
Labeling a Port Port labels serve as a useful reference point and as an accurate way to identify your ports for management. You might want to label your ATM ports so that you can easily identify the device specifically attached to each port (for example, LAN, workstation, or server).
To label an ATM port:
1 From the top level of the Administration Console, enter:
2 Enter the port(s) that you want to label.
3 Enter the label of each ATM port.
Ports labels can be a maximum of 32 characters in length. The new port label appears the next time that you display information for that port.

Listing Virtual Channel Connection
You can list general virtual channel connection (VCC) information as well as specific transmit and receive information.
Listing General VCC Information
To list general VCC information, enter the following command from the top level of the Administration Console:
Sample display of general VCC information:
VPI/VCI status aalType lastChange
0/5 localUpEndToEndUnknown 5 1 min 0/16 localUpEndToEndUnknown 5 1 hr 37 mins 25 secs 3/381 localUpEndToEndUnknown 5 2 hrs 51 mins 40 secs 3/382 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs 3/383 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs 3/384 localUpEndToEndUnknown 5 2 hrs 51 mins 40 secs 3/385 localUpEndToEndUnknown 5 2 hrs 51 mins 42 secs 3/386 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs 3/387 localUpEndToEndUnknown 5 2 hrs 51 mins 42 secs 3/388 localUpEndToEndUnknown 5 2 hrs 51 mins 41 secs
Table 9 describes the fields in the display.
Table 9 Fields in the General VCC Display
aalType Type of ATM Adaptation Layer (aal5)
lastChange Last time the circuit changed state
status Current status for the circuit
VPI/VCI The VPI and VCI for the circuit listed in the present entry
Field Description

Administering ATM Ports 57
To list virtual channel connection transmit information, enter the following command from the top level of the Administration Console:
Sample display of VCC transmit information:
VPI/VCI transmit trafficDescriptor parameter 1 parameter 2 parameter 3
CLP 0+1 pcr 0/5 atmNoClpNoScr 350490 n/a n/a
CLP 0+1 pcr 0/16 atmNoClpNoScr 350490 n/a n/a
CLP 0+1 pcr 3/381 atmNoClpNoScr 350490 n/a n/a
CLP 0+1 pcr 3/382 atmNoClpNoScr 350490 n/a n/a
CLP 0+1 pcr 3/383 atmNoClpNoScr 350490 n/a n/a
Table 10 describes the fields in the VCC transmit display:
Table 10 Fields in the VCC Transmit Display
parameter 1 parameter 2 parameter 3
Values associated with the transmit trafficDescriptor
Transmit characteristics of the circuit
VPI/VCI The VPI and VCI for the circuit listed in the present entry
Field Description · transmit trafficDescriptor

Listing VCC Receive Information
To list virtual channel connection receive information, enter the following command from the top level of the Administration Console:
Sample display of VCC receive information:
VPI/VCI receive trafficDescriptor parameter 1 parameter 2 parameter 3
CLP 0+1 pcr 0/5 atmNoClpNoScr 350490 n/a n/a
CLP 0+1 pcr 0/16 atmNoClpNoScr 350490 n/a n/a
CLP 0+1 pcr 3/381 atmNoClpNoScr 350490 n/a n/a
CLP 0+1 pcr 3/382 atmNoClpNoScr 350490 n/a n/a
Table 11 describes the fields in the VCC receive display:
Table 11 Fields in the VCC Receive Display
vpi/vci The VPI and VCI for the circuit listed in the present entry
Receive characteristics of the circuit
parameter 1 parameter 2 parameter 3
Values associated with the receive trafficDescriptor
Field Description · receive trafficDescriptor

3Com provides easy access to technical support information through a variety of services. This appendix describes these services.
Information contained in this appendix is correct at time of publication. For the most recent information, 3Com recommends that you access the 3Com Corporation World Wide Web site.
3Com offers worldwide product support 24 hours a day, 7 days a week, through the following online systems:
I World Wide Web site
I 3Com Knowledgebase Web Services
I 3Com FTP site
I 3Com Bulletin Board Service (3Com BBS)
I 3Com Facts SM
World Wide Web Site To access the latest networking information on the 3Com Corporation World Wide Web site, enter this URL into your Internet browser:
http://support.3com.com/index.htm
This service provides access to online support information such as technical documentation and software, as well as support options that range from technical education to maintenance and professional services.
This interactive tool contains technical product information compiled by 3Com expert technical engineers around the globe. Located on the World Wide Web at http://knowledgebase.3com.com, this service gives all 3Com customers and partners complementary, round-the-clock access to technical information on most 3Com products.
Automated Fax Service

3Com FTP Site Download drivers, patches, software, and MIBs across the Internet from the 3Com public FTP site. This service is available 24 hours a day, 7 days a week.
To connect to the 3Com FTP site, enter the following information into your FTP client:
You do not need a user name and password with Web browser software such as Netscape Navigator and Internet Explorer.
The 3Com BBS contains patches, software, and drivers for 3Com products. This service is available through analog modem or digital modem (ISDN) 24 hours a day, 7 days a week.
To reach the service by modem, set your modem to 8 data bits, no parity, and 1 stop bit. Call the telephone number nearest you:
Country Data Rate Telephone Number
Australia Up to 14,400 bps 61 2 9955 2073
Brazil Up to 14,400 bps 55 11 5181 9666
France Up to 14,400 bps 33 1 6986 6954
Germany Up to 28,800 bps 4989 62732 188
Hong Kong Up to 14,400 bps 852 2537 5601
Italy Up to 14,400 bps 39 2 27300680
Japan Up to 14,400 bps 81 3 5977 7977
Mexico Up to 28,800 bps 52 5 520 7835
P.R. of China Up to 14,400 bps 86 10 684 92351
Taiwan, R.O.C. Up to 14,400 bps 886 2 377 5840
U.K. Up to 28,800 bps 44 1442 438278
U.S.A. Up to 53,333 bps 1 847 262 6000

Support from Your Network Supplier 61
ISDN users can dial in to the 3Com BBS using a digital modem for fast access up to 64 Kbps. To access the 3Com BBS using ISDN, call the following number:
3Com Facts Automated Fax
The 3Com Facts automated fax service provides technical articles, diagrams, and troubleshooting instructions on 3Com products 24 hours a day, 7 days a week.
Call 3Com Facts using your Touch-Tone telephone:
Support from Your Network Supplier
If you require additional assistance, contact your network supplier. Many suppliers are authorized 3Com service partners who are qualified to provide a variety of services, including network planning, installation, hardware maintenance, application training, and support services.
When you contact your network supplier for assistance, have the following information ready:
I Product model name, part number, and serial number
I A list of system hardware and software, including revision levels
I Diagnostic error messages
I Details about recent configuration changes, if applicable
If you are unable to contact your network supplier, see the following section on how to contact 3Com.
Support from 3Com If you are unable to obtain assistance from the 3Com online technical resources or from your network supplier, 3Com offers technical telephone support services. To find out more about your support options, call the 3Com technical telephone support phone number at the location nearest you.

When you contact 3Com for assistance, have the following information ready:
I Product model name, part number, and serial number
I A list of system hardware and software, including revision levels
I Diagnostic error messages
I Details about recent configuration changes, if applicable
Here is a list of worldwide technical telephone support numbers:
Country Telephone Number Country Telephone Number
Asia Pacific Rim Australia Hong Kong India Indonesia Japan Malaysia New Zealand Pakistan Philippines
1 800 678 515 800 933 486 +61 2 9937 5085 001 800 61 009 0031 61 6439 1800 801 777 0800 446 398 +61 2 9937 5085 1235 61 266 2602
P.R. of China
10800 61 00137 or 021 6350 1590 800 6161 463
Singapore S. Korea
00798 611 2230 3455 6455 0080 611 261 001 800 611 2000
Europe From anywhere in Europe, call: +31 (0)30 6029900 phone +31 (0)30 6029999 fax
From the following countries, you may use the toll-free numbers:
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy
0800 297468 0800 71429 800 17309 0800 113153 0800 917959 0800 1821502 00800 12813 1800 553117 1800 9453794 1678 79489
Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
0800 0227788 800 11376 00800 3111206 0800 831416 0800 995014 900 983125 020 795482 0800 55 3072 0800 966197
Latin America Argentina Brazil Chile Colombia
AT&T +800 666 5065 0800 13 3266 1230 020 0645 98012 2127
Mexico Peru Puerto Rico Venezuela
01 800 CARE (01 800 2273) AT&T +800 666 5065 800 666 5065 AT&T +800 666 5065
U.S.A. and Canada 1 800 876 3266
North America

Returning Products for Repair 63
Before you send a product directly to 3Com for repair, you must first obtain an authorization number. Products sent to 3Com without authorization numbers will be returned to the sender unopened, at the sender’s expense.
To obtain an authorization number, call or fax:
Country Telephone Number Fax Number
Asia, Pacific Rim 65 543 6500 65 543 6348
Europe, South Africa, and Middle East
+ 31 30 6029900 + 31 30 6029999
From the following countries, you may call the toll-free numbers; select option 2 and then option 2:
Austria Belgium Denmark Finland France Germany Hungary Ireland Israel Italy Netherlands Norway Poland Portugal South Africa Spain Sweden Switzerland U.K.
0800 297468 0800 71429 800 17309 0800 113153 0800 917959 0800 1821502 00800 12813 1800553117 1800 9453794 1678 79489 0800 0227788 800 11376 00800 3111206 0800 831416 0800 995014 900 983125 020 795482 0800 55 3072 0800 966197
Latin America 1 408 326 2927* 1 408 326 3355*
U.S.A. and Canada 1 800 876 3266 1 408 326 7120*
* Number is not toll-free
For information on Year 2000 compliance and 3Com products, visit the 3Com Year 2000 Web page: http://www.3com.com/products/yr2000.html