CC5BCBW Series Heavy-Duty Spectra ® Back Box Installation Manual C2434M (7/01) Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100.
2 Pelco Manual C2434M (7/01) IMPOR T ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser ved. 1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
Pelco Manual C2434M (7/01) 3 DESCRIPTION The Heavy-Duty Spectra is perfect for installations where structural integrity and vandalism are a prior ity . The system features hea vy-duty constr uction and tamper-resistant barrel ke y locks . The in-ceiling model has a reinforced brac ket mounting system for installation in a fixed ceiling.
4 Pelco Manual C2434M (7/01) 00535 SPRING CLIP 8-32X.275 INCH SCREW 00537 00530 00531 00532 CEILIN G MOUNTING RING S 00533 AT TA C H S A F E T Y CHAIN HERE 00534 INST ALLA TION OF IN-CEILING MODEL STEP 1 - PREP ARE CEILING a. Locate the center point of the mount- ing location.
Pelco Manual C2434M (7/01) 5 LABEL SW1 L A B E L S W 2 SW1 SW2 RS-422 TERMINA TION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 00538 GREEN T AB RED T AB 00539 BARREL KEY LOCK BALL STUD RECEIVER BALL STUD 00497 TRIM LEASH TO USE YOUR DOME, REFER TO THE OPERA TION AND PROGRAMMING MANUAL.
6 Pelco Manual C2434M (7/01) INST ALLA TION OF PENDANT MODELS STEP 1 - DISASSEMBLE BACK BOX a. Tu rn the thumbscre w and open the hinged door located inside the back box. 01082 01081 01080 b. Unscrew the three Phillips scre ws located under neath the hinged door .
Pelco Manual C2434M (7/01) 7 STEP 3 - INST ALL THE BACK BOX 01079 01078 a. Secure the conduit fitting to the hole located on the inside base of the octagonal back box. b. Pull the cable and wiring for the system through the octagonal back box and conduit fitting.
8 Pelco Manual C2434M (7/01) STEP 5 - INST ALL DOME DRIVE LABEL SW1 L A B E L S W 2 SW1 SW2 RS-422 TERMINA TION SWITCH ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 SW2 00538 a. Set the DIP switches f or SW1 and SW2 on the bottom of the dome drive for the appropriate receiver address.
Pelco Manual C2434M (7/01) 9 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Unit does not operate. The controller is not communicating with the Spectra unit.
10 Pelco Manual C2434M (7/01) APPENDIX Ta b le A. Video Coaxial Cable Requirements Cable T ype* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) * Minimum cable requirements: 75 ohms impedance. All-copper center conductor .
Pelco Manual C2434M (7/01) 11 Ta b le D. Switch Settings f or SW2 – P-T ype Control NOTE: F or Coaxitron controls , SW2 is not used; set all s witches OFF .
12 Pelco Manual C2434M (7/01) Ta b le E. Switch Settings for SW2 – D-T ype Control (continued) (Continued on next page) Receiver Switch Setting Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-.
Pelco Manual C2434M (7/01) 13 Ta b le E. Switch Settings for SW2 – D-T ype Control (continued) Receiver Switch Setting Address SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8 161 ON OFF OFF OFF OFF .
14 Pelco Manual C2434M (7/01) SPECIFICA TIONS MECHANICAL Construction Back box: Aluminum Dome drive: Aluminum, ABS plastic Lower dome: Acrylic Cable Entry In-Ceiling: .
Pelco Manual C2434M (7/01) 15 GENERAL Environment In-Ceiling: Indoor only Pendant: Indoor/outdoor Operating Range In-Ceiling: 32 to 122 ° F (0 to 50 ° C) Pendant: (Assumes no wind chill factor; for detailed test conditions, contact Pelco) Maximum: 140 ° F (60 ° C) absolute maximum 122 ° F (50 ° C) sustained maximum Minimum -15 ° F (-9.
16 Pelco Manual C2434M (7/01) REVISION HISTOR Y Manual # Date Comments C2434M 7/01 Original version. P elco, the P elco logo, Camclosure , Esprit, Genex, Legacy , and Spectra are registered trademarks of P elco. © Copyright 2001, Pelc o. Endura and ExSite are trademarks of P elco.
An important point after buying a device Pelco C2434M (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Pelco C2434M yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Pelco C2434M - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Pelco C2434M you will learn all the available features of the product, as well as information on its operation. The information that you get Pelco C2434M will certainly help you make a decision on the purchase.
If you already are a holder of Pelco C2434M, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Pelco C2434M.
However, one of the most important roles played by the user manual is to help in solving problems with Pelco C2434M. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Pelco C2434M along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center