EN
Patton electronic logo
Official user manual

Patton electronic 6511RC

104 pages·6 MB·Switch·PDF·ENDEFRITNLJA
Patton electronic 6511RC
Table of Contents 131 sections Contents · Compliance Information · Radio and TV Interference · Industry Canada Notice · … ShowHide
Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 1 of the Patton electronic 6511RC user manual — Model 6511RC Matrix Switch
Page 1 · click to enlarge
Page 1

Model 6511RC Matrix Switch

User Manual

Patton electronic 6511RC — Model 6511RC Matrix Switch diagram (page 1)
Fig. 1 · Model 6511RC Matrix Switch
Sales Office+1 (301) 975-1000 Technical Support: +1 (301) 975-1007
E-mailsupport@ patton.com
WWWwww.patton.com
Part Number07MD6511RC-GS, Rev. B
RevisedFebruary 20, 2012
Page 2 of the Patton electronic 6511RC user manual
Page 2 · click to enlarge
Page 2

Patton Electronics Company, Inc.

7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

tel+1 (301) 975-1000 fax: +1 (301) 869-9293 support: +1 (301) 975-1007
urlwww.patton.com e-mail: support@ patton.com

Copyright © 2012, Patton Electronics Company. All rights reserved.

The information in this document is subject to change without notice. Patton

Electronics assumes no liability for errors that may appear in this document.

The software described in this document is furnished under a license and may

be used or copied only in accordance with the terms of such license.

Page 3 of the Patton electronic 6511RC user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 7 of the Patton electronic 6511RC user manual — Compliance Information
Page 7 · click to enlarge
Page 7

Compliance Information

Radio and TV Interference The Model 6511RC generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. The Model 6511RC has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide rea- sonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 6511RC causes interference to radio or tele- vision reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the comput- ing equipment and receiver are on different branches).

Users should not attempt to establish or modify ground connections themselves, instead they should contact the appropriate electric inspection authority or electrician.

FCC Part 68 (ACTA) Statement This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.

A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.

This equipment uses a Universal Service Order Code (USOC) jack: RJ-11C.

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.

Industry Canada Notice

Page 8 of the Patton electronic 6511RC user manual — CE Notice
Page 8 · click to enlarge
Page 8

Compliance Information Model 6511RC User Manual

If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you dis- connect the equipment until the problem is resolved.

Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

In accordance with FCC rules and regulation CFR 47 68.218(b)(6), you must notify the telephone company prior to disconnection. The following information may be required when applying to your local telephone company for leased line facilities. The Universal Service Order Code (USOC) is RJ48. The Facility Interface Codes (FIC) are 04DU9-BN, 04DU9-DN, 04DU9-1KN, and 04DU9-1SN. The Service Order Code (SOC) is 6.0N.

ServiceFacility Interface CodeService CodeNetwork Connection 1.544 Mbps SF format without line power04DU9-BN6.0NRJ-48C 1.544 Mbps SF and B8ZS without line power04DU9-DN6.0NRJ-48C 1.544 Mbps ANSI ESF without line power04DU9-1KN6.0NRJ-48C 1.544 Mbps ANSI ESF and B8ZS without line power04DU9-1SN6.0NRJ-48C

CE Notice The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromag- netic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Certificate of Compliance is available by contacting Technical Support.

Page 9 of the Patton electronic 6511RC user manual — Structure
Page 9 · click to enlarge
Page 9

About this guide

This guide describes installing and configuring a Patton Electronics Model 6511 TDM-Digital Access Con- centrator (Matrix Switch). By the time you are finished with this guide, your Matrix Switch will be connected to the remote DSL modems and transferring data. The instructions in this guide are based on the following assumptions:

  • The Matrix Switch is installed in a Patton ForeFront chassis
  • The Matrix Switch will connect to an SDH/STM-1 network
  • There is a LAN connected to one of the Matrix Switch’s Ethernet ports

Audience

This guide is intended for the following users:

  • Operators
  • Installers
  • Maintenance technicians

Structure

This guide contains the following chapters and appendices:

  • Chapter 1 describes the Matrix Switch
  • Chapter 2 describes installing the Matrix Switch hardware
  • Chapter 3 describes configuring the Matrix Switch for use
  • Chapter 4 details how to power up and deactivate the Matrix Switch
  • Chapter 5 contains troubleshooting and maintenance information
  • Chapter 6 contains information on contacting Patton technical support for assistance

For best results, read the contents of this guide before you install the Matrix Switch.

Page 10 of the Patton electronic 6511RC user manual — Typographical conventions used in this document
Page 10 · click to enlarge
Page 10

About this guide Model 6511RC User Manual

Precautions

The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.

The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.

The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.

The alert symbol and CAUTION heading indicate a potential haz- ard. Strictly follow the instructions to avoid property damage.

Typographical conventions used in this document

This section describes the typographical conventions and terms used in this guide.

General conventions The procedures described in this manual use the following text conventions:

Table 1. General conventions

ConventionMeaning Garamond blue typeIndicates a cross-reference hyperlink that points to a figure, graphic, table, or section heading. Clicking on the hyperlink jumps you to the reference. When you have finished reviewing the reference, click on the Go to Previous View button in the Adobe® Acrobat® Reader toolbar to return to your starting point. Futura bold typeIndicates the names of menu bar options. Italicized Futura typeIndicates the names of options on pull-down menus. Futura typeIndicates the names of fields or windows. Garamond bold typeIndicates the names of command buttons that execute an action. < >Angle brackets indicate function and keyboard keys, such as <SHIFT>, <CTRL>, <C>, and so on.
Page 11 of the Patton electronic 6511RC user manual — Mouse conventions
Page 11 · click to enlarge
Page 11

Model 6511RC User Manual About this guide

Table 1. General conventions (Continued)

ConventionMeaning Are you ready?All system messages and prompts appear in the Courier font as the system would display them. % dir *.*Bold Courier font indicates where the operator must type a response or command

Mouse conventions The following conventions are used when describing mouse actions:

Table 2. Mouse conventions

ConventionMeaning Left mouse buttonThis button refers to the primary or leftmost mouse button (unless you have changed the default configuration). Right mouse buttonThis button refers the secondary or rightmost mouse button (unless you have changed the default configuration). PointThis word means to move the mouse in such a way that the tip of the pointing arrow on the screen ends up resting at the desired location. ClickMeans to quickly press and release the left or right mouse button (as instructed in the procedure). Make sure you do not move the mouse pointer while clicking a mouse button. Double-clickMeans to press and release the same mouse button two times quickly DragThis word means to point the arrow and then hold down the left or right mouse button (as instructed in the procedure) as you move the mouse to a new location. When you have moved the mouse pointer to the desired location, you can release the mouse button.
Page 12 of the Patton electronic 6511RC user manual — Mouse conventions
Page 12 · click to enlarge
Page 12

About this guide Model 6511RC User Manual

Page 13 of the Patton electronic 6511RC user manual — Table of contents
Page 13 · click to enlarge
Page 13

Table of contents

Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 14 of the Patton electronic 6511RC user manual — Model 6511RC Matrix Switch overview
Page 14 · click to enlarge
Page 14

1 • Introduction Model 6511RC User Manual

Model 6511RC Matrix Switch overview

The Model 6511RC Matrix Switch (see figure 1) combines TDM aggregation and cross-connection with high- speed packet switching over synchronous digital hierarchy (SDH) and Ethernet uplinks for the Patton Fore- Front Access Infrastructure Solutions (AIS) system. The web-manageable Matrix Switch provides a fully non- blocking mapping and switching matrix for TDM and Ethernet traffic traversing the ForeFront chassis or chas- sis segment. With the Model 6511RC, ForeFront AIS can deliver aggregated TDM and IP traffic on high- speed SDH and Ethernet trunks. The Matrix Switch is designed for installation and operation in either the ForeFront Xtreme Model 6676 cPCI 9U chassis or the ForeFront FullPipe Model 6476 6U chassis. Each model 6511RC Matrix Switch includes an on-board TDM multiplexer, a powerful Ethernet switch, a 155 Mbps SDH/STM-1 trunk port, and two 10/100/1000 Mbps Ethernet interfaces for high-speed packet- switched uplinks.

Patton electronic 6511RC — Model 6511RC Matrix Switch overview diagram (page 14)
Fig. 2 · Model 6511RC Matrix Switch overview

Figure 1. Model 6511RC Matrix Switch front blade

14 Model 6511RC Matrix Switch overview

Page 15 of the Patton electronic 6511RC user manual — Model 6511RC Matrix Switch overview
Page 15 · click to enlarge
Page 15

Model 6511RC User Manual 1 • Introduction

Figure 2 shows the major functions and connections the Matrix Switch provides within the ForeFront chassis. Each Model 6511RC enables service providers to perform SDH multiplexing and demultiplexing with any-to- any timeslot mapping for up to 2048 DS0 channels. The on-board TDM multiplexer can map any of the 4096 DS0 timeslots on the TDM bus in the chassis midplane to any of the 2048 DS0s on the STM-1 uplink. Each DS0 consists of a 64 kbps communication channel, or timeslot. The integrated SDH aggregator combines DS0 channels into E1 signal streams, then maps those E1s into a STM-1 signal for high-speed transmission on the SDH trunk.

Patton electronic 6511RC — Model 6511RC Matrix Switch overview diagram (page 15)
Fig. 3 · Model 6511RC Matrix Switch overview

Figure 2. Model 6511RC Matrix Switch major functions and interfaces

The Model 6511RC provides an Ethernet-switching fabric for packet-based management and user traffic tra- versing the ForeFront chassis. The powerful Ethernet switch connects the high-speed packet-switched bus in the ForeFront chassis midplane with two 10/100/1000 Ethernet uplinks. Offering fast Ethernet switching and flexible timeslot aggregation, the Model 6511RC Matrix Switch enables the ForeFront AIS system to deliver a surprisingly compact, high-speed trunking solution at very low cost.

Model 6511RC Matrix Switch overview 15

Page 16 of the Patton electronic 6511RC user manual — Hardware overview
Page 16 · click to enlarge
Page 16

1 • Introduction Model 6511RC User Manual

Hardware overview

The Model 6511RC combines DS0 cross-connection and concentration with powerful Ethernet switching in a single-slot blade for installation in a standard CPCI chassis. The Matrix Switch card-set comprises two mod- ules, a processor blade (see figure 1 on page 14) inserted from the front of the ForeFront chassis, and a rear interface blade (see figure 3) inserted opposite to the processor blade. The front and rear blades mate at the mid-plane, which provides the communication path between front and rear blades (see figure 4).

Patton electronic 6511RC — Hardware overview diagram (page 16)
Fig. 4 · Hardware overview

Figure 3. Model 6511RCT rear blade

Figure 4. Model 6511RC Matrix Switch front and rear blade installation

Show 6 more labels / short text on this page
Midplane · Front Blade · Rear Blade · Front Rear · Side view · 16 Hardware overview
Page 17 of the Patton electronic 6511RC user manual — Hardware overview
Page 17 · click to enlarge
Page 17

Model 6511RC User Manual 1 • Introduction

Patton electronic 6511RC — Hardware overview diagram (page 17)
Fig. 5 · Hardware overview

Figure 5. Model 6511RC front panel LEDs and ports

The front panel of the processor blade presents LED status indicators, an RS-232 configuration port and a 10/100 Ethernet management port (see figure 5). The rear entry interface blade (see figure 6 on page 18) pre- sents LEDs indicating alarm and WAN status, physical connectors for the STM-1 port, as well as two 10/100/1000 Ethernet RJ-45 connectors with embedded link and activity status indicator LEDs.

Hardware overview 17

Page 18 of the Patton electronic 6511RC user manual — Hardware overview
Page 18 · click to enlarge
Page 18

1 • Introduction Model 6511RC User Manual

Patton electronic 6511RC — Hardware overview diagram (page 18)
Fig. 6 · Hardware overview

Figure 6. Model 6511RCT rear entry car front panel LEDs and ports

Three versions of the rear card offer the following connector types for the STM-1 port:

  • SC20— Optical interface presented on Rx and Tx SC connectors for singlemode fiber with a wavelength of 1310 nm. The interface complies with ITU specifications G.957 and G.652.
  • EBNC— Electrical interface presented on Rx and Tx 75-ohm BNC connectors.
  • SC20/EBNC— Optical and electrical interfaces as described previously.

The Model 6511RC connects to other blades in the chassis via the ForeFront cPCI chassis midplane. The chas- sis mid-plane contains two digital communications busses, the H.110 TDM bus, and the PICMG 2.16 Packet-Switched Ethernet bus. The front blade connects to both busses via connectors on the chassis mid- plane. The blade uses the two mid-plane busses for digital communications with other processor blades installed and operating in the chassis.

18 Hardware overview

Page 19 of the Patton electronic 6511RC user manual — ForeFront chassis architectures
Page 19 · click to enlarge
Page 19

Model 6511RC User Manual 1 • Introduction

ForeFront chassis architectures The Model 6511RC can be installed in the following ForeFront cPCI chassis:

  • Model 6476 6U chassis
  • Model 6676 9U chassis

ForeFront Model 6476 6U cPCI chassis The ForeFront Model 6476 6U cPCI chassis provides 8 slots for installing cPCI processor blades (see figure 7). The Model 6476 chassis accepts up to two Model 6511RC blades, installed in the fabric slots (designated by a yellow blade guide). Using the H.110 TDM and PICMG 2.16 packet busses residing in the chassis mid-plane, an installed Model 6511 can communicate with the other blades installed and operating in the remaining slots.

Patton electronic 6511RC — ForeFront chassis architectures diagram (page 19)
Fig. 7 · ForeFront chassis architectures

Figure 7. Model 6476 chassis, front view

Hardware overview 19

Page 20 of the Patton electronic 6511RC user manual — The ForeFront Model 6676 9U chassis
Page 20 · click to enlarge
Page 20

1 • Introduction Model 6511RC User Manual

Patton electronic 6511RC — The ForeFront Model 6676 9U chassis diagram (page 20)
Fig. 8 · The ForeFront Model 6676 9U chassis

Figure 8. Model 6676 chassis, front view

The ForeFront Model 6676 9U chassis The ForeFront Model 6676 9U chassis offers 17 slots for installing cPCI processor blades (see figure 8). The Model 6676 midplane is divided into segment R (slots 1 through 8) and segment L (slots 9 through 17). Each mid-plane segment contains its own H.110 and PICMG 2.16 bus, so since each 6511RC connects to one mid- plane segment, two Matrix Switch blades, installed in each of the two segments, are required to serve an entire Model 6676 chassis. The Model 6676 chassis can accept up to four Model 6511RC blades installed in slots called fabric slots (slots 1, 2, 9, and 10) designated by yellow card guides. In each backplane segment, a maxi- mum of two 6511RC blades can be installed for operation to provide switching functions for that segment.

20 Hardware overview

Page 21 of the Patton electronic 6511RC user manual — Matrix Switch functionality
Page 21 · click to enlarge
Page 21

Model 6511RC User Manual 1 • Introduction

The Model 6511 communicates with the other blades installed and operating in the same segment over the H.110 TDM and PICMG 2.16 packet busses residing in the chassis mid-plane.

Matrix Switch functionality The Model 6511 provides the following functionality:

  • TDM mapping and aggregation—The Model 6511RC Matrix Switch concentrates the traffic capacity of up to 63 E1 lines for delivery on a 155.54 Mbps optical or electrical STM-1 uplink (see section “TDM mapping and aggregation” for details)
  • TDM bus architecture—The Matrix Switch provides an interface to the H.110 bus within the ForeFront chassis.The total capacity of the H.110 bus is 4096 half-duplex DS0 channels, the equivalent of 64 E1 lines (see section “TDM bus architecture” for details)
  • STM-1 link architecture—The 155.52 Mbps STM-1 uplink carries 2016 full-duplex (4032 half-duplex) DS0 channels organized into 63 E1 signal streams. Each E1 stream carries 32 full-duplex DS0 channels (64 half-duplex timeslots). The total capacity of the STM-1 uplink on the Model 6511RC is 2016 full-duplex DS0s, the equivalent of 63 E1 lines (see section “STM-1 link architecture” on page 22 for details)
  • Matrix Switch TDM capacity—The Matrix Switch provides the means for you to map any DS0 on the H.110 TDM bus to any DS0 on the STM-1 trunk and vice-versa (see section “Matrix Switch TDM capacity” on page 23 for details)

TDM mapping and aggregation The Model 6511RC Matrix Switch concentrates the traffic capacity of up to 63 E1 lines for delivery on a 155.54 Mbps optical or electrical STM-1 uplink. For E1 traffic aggregation, the Matrix Switch performs mul- tiplexing and demultiplexing for all 63 E1 lines comprising the 155.52 Mbps STM-1 uplink. Each E1 line comprises 32 DS0 timeslots. Each timeslot comprises a 64 kbps communication channel, or DS0. The Model 6511RC delivers a fully non-blocking switching matrix to the ForeFront system, providing any-to-any map- ping between all 4096 half-duplex DS0 timeslots carried in the H.110 bus and all 4032 half-duplex DS0 timeslots in the SDH STM-1 uplink.

Hardware overview 21

Page 22 of the Patton electronic 6511RC user manual — TDM bus architecture
Page 22 · click to enlarge
Page 22

1 • Introduction Model 6511RC User Manual

TDM bus architecture The Matrix Switch provides an interface to the H.110 bus within the ForeFront chassis.The total capacity of the H.110 bus is 4096 half-duplex DS0 channels, the equivalent of 64 E1 lines (see figure 9). Each DS0 chan- nel can be mapped in either direction, transmitting to the Matrix Switch or receiving from the H.110 bus. The H.110 bus organizes the 4096 half-duplex DS0 channels into 32 H.110 ports. Each of the 32 H.110 ports car- ries 128 half-duplex 64 kbps timeslots (DS0s).

Patton electronic 6511RC — TDM bus architecture diagram (page 22)
Fig. 9 · TDM bus architecture

Figure 9. H.110 bus and STM-Link capacity

STM-1 link architecture The 155.52 Mbps STM-1 uplink carries 2016 full-duplex (4032 half-duplex) DS0 channels organized into 63 E1 signal streams. Each E1 stream carries 32 full-duplex DS0 channels (64 half-duplex timeslots). The total capacity of the STM-1 uplink on the Model 6511RC is 2016 full-duplex DS0s, the equivalent of 63 E1 lines. The following sequence describes the process by which the Matrix Switch maps and multiplexes 63 E1 streams into the architecture of the STM-1 signal stream:

  • E1 -toC-12 -toVC-12 -toTU-12 -toTUG-2 -toVC-3 -toAU-3 -toAUG-1 -toSTM-1

Multiplexing occurs at the following points in the mapping sequence:

- Three TU-12s are multiplexed into one tributary unit group-2 (TUG-2).

- Seven TUG-2s are multiplexed into one TUG-3 or administrative unit-3 (AU-3).

- Three AU-3s or TUG-3s are multiplexed into one administrative unit group-1 (AUG-1).

22 Hardware overview

Page 23 of the Patton electronic 6511RC user manual — Matrix Switch TDM capacity
Page 23 · click to enlarge
Page 23

Model 6511RC User Manual 1 • Introduction

Figure 10 highlights the multiplexing structure of the STM-1 link by ommitting the intermediate steps in the SDH mapping sequence

Patton electronic 6511RC — Matrix Switch TDM capacity diagram (page 23)
Fig. 10 · Matrix Switch TDM capacity

Figure 10. E1-to-STM-1 multiplexing structure

Matrix Switch TDM capacity The Matrix Switch provides the means for you to map any DS0 on the H.110 TDM bus to any DS0 on the STM-1 trunk and vice-versa. The difference in capacity between the H.110 bus and the STM-1 link is 64 half- duplex DS0s, the equivalent of one E1 line. The STM-1 uplink provides sufficient capacity to aggregate 98% of the traffic capacity of the H.110 TDM bus. The Model 6511RC provides the capability to map and aggre- gate traffic on the H.110 bus up to the full capacity of the STM-1 trunk.

Matrix Switch Ethernet Switching The Matrix Switch also delivers Ethernet connectivity and switching for any Ethernet traffic traversing the PICMG 2.16 bus to which the blade is connected. The Model 6511RC provides the Ethernet switching fabric for all other blades connected to the same PICMG 2.16 packet-switching bus within the chassis mid-plane. The built-in Ethernet switch switches Ethernet traffic between the PICMG 2.16 bus, the 10/100 Ethernet LAN port presented on the front panel of the front blade, and the two 10/100/1000 Ethernet WAN uplink ports presented on the 6511RCrear panel of the rear blade. All three Ethernet ports provide access to the SNMP agent and HTTP Web Management services within the 6511RC. In addition, all three Ethernet ports provide access via the Internet Protocol to the other blades on the packet bus, including access to the Web Management services residing within those blades. When combined with an external network management system, the Ethernet switching feature on the 6511RC makes it possible to implement a packet-based network management solution for all system elements connected to the same packet-switched bus in the ForeFront chassis.

Hardware overview 23

Page 24 of the Patton electronic 6511RC user manual — Management
Page 24 · click to enlarge
Page 24

1 • Introduction Model 6511RC User Manual

Management Services By providing a rich set of industry-standard management services accessible by a full menu of physical inter- faces, the Model 6511RC offers an extensive selection of management options. The Matrix Switch provides the following management services:

  • HTTP Web-Management Interface accessible via any standard web browser
  • SNMP version 1 configuration management (specified in RFC 1157)
  • MIB II (specified in RFC 1213)
  • Command Line Management Interface (CLI)
  • SYSLOG Management Client (specified in RFC 3164)
  • Out-of-Band RS-232 configuration port for management and control
  • TELNET via Ethernet
  • Remote Software Upgrade via FTP/TFTP

Management Interfaces You can reach the Matrix Switch’s management services via any of the following physical interfaces:

  • RS-232 Config Port presented as an RJ-45 connector on the front panel of the front blade
  • PICMG 2.16 midplane connector block on the front blade
  • 10/100 Ethernet port presented as an RJ-45 connector on the front panel of the front blade.
  • Two 10/100/1000 Ethernet ports presented as RJ-45 connectors on the rear panel of the rear blade

Management Approach Managing the Model 6511RC’s may be approached using one of two schemes, generally referred to as In-band or Out-of-band management. In-band management refers to those schemes in which management informa- tion traverses the same network resources as network user traffic. Out-of-band management refers scenarios in which management information does not traverse the same resources as network user traffic. In other words, out-of-band management involves implementing a secondary, special-purpose, management network dedi- cated to carrying management information about the primary, user network. In-band management is more efficient. However, because management information is susceptible to failures in the user network., it is less reliable. Out-of-band management, while more reliable, is also more costly because it involves more equip- ment.

Management access paths into the Model 6511RC for both In-band and Out-of-band approaches are described below.

  • In-band management access paths include:

- The two RJ-45 10/100/1000 Ethernet trunk ports on the rear panel of the rear blade support in-band

management for applications where the Ethernet link is used as an aggregated trunk for user traffic as well as a path for management information. An external management workstation communicates with the management services in the Matrix Switch via a routed-protocol connection within the Ethernet link. The management connection terminates at the management service within the Matrix Switch.

Management · 24 Hardware overview

Page 25 of the Patton electronic 6511RC user manual — Matrix Switch Interfaces
Page 25 · click to enlarge
Page 25

Model 6511RC User Manual 1 • Introduction

- The PICMG 2.16 packet-switched bus (PSB). In order to manage the Matrix Switch in-band via the

PICMG 2.16 PSB, an external management workstation connects to the ForeFront chassis via another ForeFront blade with management routing capability, such as the Model 6801RC EdgeRoute Network Access Server or model 3096RC TDM Digital Access Concentrator, operating on the same bus. The external management workstation communicates with the ForeFront system using either a Frame Relay or PPP link within a DS0 or within an Ethernet link. The in-band management link terminates on the module with management routing capability, which in turn communicates with the management services in the Matrix Switch over the PICMG 2.16 PSB.

  • Out-of-band management access paths include:

- The RS-232 config port on the front panel of the front blade

- The RJ-45 10/100 Ethernet LAN port on the front panel of the front blade

- The two RJ-45 10/100/1000 Ethernet LAN ports on the rear panel of the rear blade, in applications

where these Ethernet links are dedicated to management traffic.

WAN Interfaces The 6511RC provides connections to the following WAN interfaces:

  • One SDH STM-1 uplink trunk port at 155.54 Mbps -Physical SC or BNC connectors presented on the rear-blade rear panel
  • Two Ethernet trunk ports at up to 1 Gbps -Physical RJ-45 connectors presented on the rear-blade rear panel

The STM-1 WAN uplink port may be connected to an SDH network via the Optical SC ore electrical BNC connectors presented on the rear blade.

Mid-Plane Interfaces • Connection to the H.110 Time-Division Multiplexed bus providing 4096 DS0 channels of 64 kbps each -Physical and electrical connections via the mid-plane connector block on the rear of the front blade

  • Connection to the PICMG 2.16 Packet-Switched Bus (PSB) -Physical and electrical connections via the mid-plane connector block on the rear of the front blade

LAN Interface The 10/100-Mbps Ethernet LAN port is presented on an RJ-45 connector with an auto-sensing/full-duplex 10Base-T or 100Base-T interface. Also included are:

  • 100Base-TX half-/full-duplex operation (100 + 100)
  • 10Base-T half-/full-duplex operation (10 + 10)
  • Auto detection and fallback
  • 10/100 Mbps link and status indicators

Matrix Switch Interfaces · Hardware overview 25

Page 26 of the Patton electronic 6511RC user manual — RS-232 Config port
Page 26 · click to enlarge
Page 26

1 • Introduction Model 6511RC User Manual

RS-232 Config port The RS-232 Config port provides access to the CLI management service. You will use the Config port to per- form initial configuration of the Model 6511RC. The RS-232 port supports:

  • Asynchronous data rates of 19.2 kbps, 8 data bits, no parity, 1 stop bit.
  • An RJ-45 connector with EIA-561 pinouts
  • A management interface that supports VT-100 terminals
  • Hardware flow control (RTS and CTS)

Power system The 6511RC obtains power from the CPCI chassis via PCMG 2.11 47-pin power connectors on the front and rear blade. Total power consumption is a maximum of 43 Watts, provided by modular power supplies installed in the cPCI chassis.

Central processing unit The 6511RC employs an Intel i960VH RISC processor operating at 100 MHz/100 Mips. The CPU controls the memory, front/back-panel and management interface for DS0 timeslot mapping, Ethernet switching, loop- back and management services. System memory provided by:

  • 4 MB Flash ROM
  • 8 MB EDO DRAM

System timing The system timing for the Matrix Switch must be configured using the blade’s management services, typically via Web Management.

Clocking Mode When configured in Master mode, the Matrix Switch serves as the Master clock source (timing reference) for all other blades on the same H.100 bus within the Model 6476 chassis or Model 6676 chassis segment. When configured in Backup mode, the Matrix Switch serves as an alternate Master clocking source (backup) should the Master clocking source fail. When configured in Slave mode, the Matrix Switch will not provide system timing over the H.100 bus for any other blades.

Clocking Source Regardless of its clocking mode, the Matrix Switch can derive its own system timing from several sources. You will define two clocking sources for the Matrix Switch, a first-choice (Primary Reference) and an alternate (Fallback Reference). The Matrix switch will derive its own system timing from the Primary Reference as long as it remains available. Should the Primary Reference become unavailable, the Matrix Switch will switch over to the Fallback reference as the clock source for its own system timing. The following clocking sources can serve as either the Primary Reference or Fallback Reference for the Matrix Switch:

  • The internal oscillator (clock) residing on the Matrix Switch front blade
  • A network clock recovered from the STM-1 SDH signal stream
  • Another blade operating in either Primary or Secondary mode on the same bus.

26 Hardware overview

Page 27 of the Patton electronic 6511RC user manual — Temperature
Page 27 · click to enlarge
Page 27

Model 6511RC User Manual 1 • Introduction

Temperature Operating range32–104°F (0–40°C)
Altitude Maximum operating altitude15,000 feet (4,752 meters)

Humidity 5 to 95% relative humidity (RH), non-condensing

Physical dimensions • 1.75 inches (4.44 cm) height, standard 19-inch (48.26 cm) width, 12-inch (30.48 cm) depth

  • Weight: 1.55 lbs (0.70 kg)

LED Indicators LED indicators on the front panel (see figure 5 on page 17) and rear panel (see figure 6 on page 18) display the status of Matrix Switch system resources. The front-panel LEDs are described in table 3. The rear-panel LEDs are described in table 4 on page 28.

Table 3. Front-panel LED indicators

LED Color Status Meaning

POWER Green On solid Power is being applied.

Flashing The 6511RC has detected a power failure on a power bus.

Off No input power is being applied.

CPU FAIL Red On solid CPU is unable to load the software from FLASH to RAM for operation.

Off The CPU is operating normally.

ALARM Yellow On solid A minor alarm condition has been detected.

Flashing A major alarm condition has been detected.

Off The Model 6511RC system is operating normally.

SYSTEM Green Flashing The Model 6511RC system is operating normally.

Off The Model 6511RCsystem is not functioning properly.

ENET(NODE) Green On solid Indicates there is Ethernet frame activity on one or more of the 6511RC’s Ethernet inter-

faces, including the two rear-panel 10/100/1000 ports, the front -panel 10/100 port, and the packet--switched PICMG 2.16 bus.

Off Indicates NO Ethernet frame activity detected on any of the 6511RC’s Ethernet interfaces, including the PICMG 2.16 bus.

CLK SOURCE Green On solid The 6511RC is defined as the Primary (master) clock source for the H.100 bus

Flashing The 6511RC is defined as the Secondary (alternate master) clock source.

Off The 6511RC is defined as a slave, deriving its clock from the H.110 Bus.

CLK ERROR Yellow On solid Primary Master Clock source has been lost and the 6511RC is using the secondary

source for its clock.

Flashing Master Clock source and the Secondary Clock source have been lost and the 6511RC

is using its internal crystal for its clock.

Off No clock errors currently detected.

Hardware overview 27

Page 28 of the Patton electronic 6511RC user manual — Temperature
Page 28 · click to enlarge
Page 28

1 • Introduction Model 6511RC User Manual

Table 3. Front-panel LED indicators (Continued)

LED Color Status Meaning

TEST MODE Green On solid One or more Ethernet ports or the STM-1 port is in test mode.

Flashing One or more Ethernet ports or the STM-1 port is in test mode and errors have been

received.

Off None of the ports is operating in test mode.

WAN Green On solid Indicates the STM-1 port is activated, synched, and operating normally.

Flashing Indicates that the STM-1 port is detecting the SDH network, but is unable to synchro-

nize with it.

Off Indicates rear blade not present or STM-1 port is not configured

ENET(SWITCH) Green On solid Indicates there is Ethernet frame activity on at least one of the eight PICMG 2.16 connec-

tions to other blades on the PSB bus.

Off No Ethernet frame activity detected on the PICMG 2.16 bus.

ENET(REAR) Green On Indicates Ethernet frame activity on one or both of the 10/100/1000 Ethernet ports

Off There is NO Ethernet frame activity on either of the 10/100/1000 Ethernet ports

ON LINE On Reserved for future use

Off Reserved for future use

10/100 ENET Green On Ethernet Link is established

Integrated LEDs Off No Ethernet link is established

on RJ-45 Yellow On Flashes to indicates Ethernet frame activity on this port

Connector Off Indicates no Etherent frame activity on this port

READY Blue On Card ready for removal from cPCI chassis.

Off Card not ready for removal from cPCI chassis.

Table 4. Rear-panel LED indicators

Patton electronic 6511RC — Temperature diagram (page 28)
Fig. 11 · Temperature

ALARM Red On solid A minor alarm condition has been detected.

WAN Green On solid Indicates the STM-1 port is activated, synched, and operating normally.

Flashing Indicates that the STM-1 port is detecting the SDH network, but is unable to synchro-

Off Indicates rear blade not present or STM-1 port is not configured

on RJ-45 Yellow On Flashes to indicates Ethernet frame activity on this port

Connector Off Indicates no Etherent frame activity on this port

on RJ-45 On Flashes to indicates Ethernet frame activity on this port

Connector Off Indicates no Etherent frame activity on this port

Ready Blue On Card ready for removal from cPCI chassis.

Off Card not ready for removal from cPCI chassis.

28 Hardware overview

Page 29 of the Patton electronic 6511RC user manual — - ETSI CTR 12
Page 29 · click to enlarge
Page 29

Model 6511RC User Manual 1 • Introduction

Approvals

The Model 6511RC Matrix Switch has achieved the following approvals and certifications:

  • Safety

- UL 60950

- Industry Canada CSA C22.2 No. 60950

  • RTTE Directive (CE Mark)

- EMC Directive 89/336/EEC

- Low Voltage Directive 73/23/EEC (EN 60950)

- ETSI CTR 12

- ETSI CTR 13

  • EMC

- FCC Part 15, Subpart B, Class A

  • Telecom

- FCC Part 68

- Industry Canada CS-03

Approvals 29

Page 30 of the Patton electronic 6511RC user manual — Approvals
Page 30 · click to enlarge
Page 30

1 • Introduction Model 6511RC User Manual

30 Approvals

Page 31 of the Patton electronic 6511RC user manual — Table of contents
Page 31 · click to enlarge
Page 31

Table of contents

Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 32 of the Patton electronic 6511RC user manual — Verifying that the ForeFront chassis is properly installed
Page 32 · click to enlarge
Page 32

2 • Hardware installation Model 6511RC User Manual

Introduction

This chapter contains the following procedures for installing the Model 6511RC Matrix Switch:

  • “Unpacking the Model 6511RC Matrix Switch” —lists the contents in the Matrix Switch shipping container
  • “Matrix Switch hardware installation” —describes installing the Matrix Switch on a flat surface or in a standard 19-inch rack
  • “Installing the network cables” on page 35—describes installing the power and network interface cables
  • “Completing the hardware installation” on page 40—describes testing the Matrix Switch hardware to verify that it is ready for software configuration

Unpacking the Model 6511RC Matrix Switch

Inspect the shipping carton for external damage. Note any damage before removing the container contents. Report equipment damage to the shipping carrier immediately for claim purposes. Save all packing materials in case you need to return an item to the factory for servicing.

The Matrix Switch comes with the following items:

  • The Model 6511RC Digital Cross-Connect (Matrix Switch)
  • One RJ45-to-RJ45 cable for use with the console and Ethernet ports
  • A DB9-RJ45 (EIA-561) adapter for connecting a PC's serial port to the Matrix Switch console port

Verifying that the ForeFront chassis is properly installed

You must verify that the ForeFront chassis is correctly installed before installing the Matrix Switch hardware into the chassis. Check for the following:

  • Correct electrical grounding —Improper chassis grounding may impair proper operation of the STM-1 electrical interface, thereby causing data transmission errors on the STM-1 link. See section “Verfying correct electrical grounding” on page 33 for directions on verify chassis grounding.
  • Correctly installed front and rear panels over vacant chassis slots —Absent front or rear panels over vacant module slots leaves the chassis interior open and thereby vulnerable to the following problems:

- Improper EMI shielding against both incoming and outgoing electromagnetic signals

- Impaired operation of the chassis cooling system, resulting in equipment overheating, including the SHD

laser subsystem on the Matrix Switch

See section “Verifying correct cover plate installation” on page 33 for directions on verifying proper cover plate installation

32 Introduction

Page 33 of the Patton electronic 6511RC user manual — Verfying correct electrical grounding
Page 33 · click to enlarge
Page 33

Model 6511RC User Manual 2 • Hardware installation

Verfying correct electrical grounding Do the following to verify correct electrical grounding:

Improper chassis grounding may impair the operation of the STM-1 electrical interface, thereby causing data transmission errors on the STM-1 link.

1. Inspect the rack chassis grounding studs on the AC power module or DC power module (see figure 11 for studs locations) to ensure a #12 AWG ground wire is attached.
Patton electronic 6511RC — Verfying correct electrical grounding diagram (page 33)
Fig. 12 · Verfying correct electrical grounding

Figure 11. AC power module and DC power module grounding studs locations

2. Inspect the remote end the #10 AWG ground wire and verify that it is attached to one of the following grounding sources:

– The building ground rod (generally located at the site’s main service entrance)

– A sprinkler system pipe

– A cold-water pipe

– Building structural steel

Verifying correct cover plate installation Missing front or rear panel cover plates leave the chassis interior open and vulnerable to the following problems:

  • Impaired EMI shielding against incoming and outgoing electromagnetic signals
  • Reduced chassis cooling system efficiency, which can resulting in equipment overheating, especially in the SHD laser subsystem on the Matrix Switch

Do the following to verify that cover plates are properly installed:

1. Inspect the front of the chassis and verify that a cover plate is installed for each vacant module slot, and verify that each cover plate’s fasteners are tightened securely to the front panel. Missing cover plates must be replaced before installing the Matrix Switch.

Verifying that the ForeFront chassis is properly installed 33

Page 34 of the Patton electronic 6511RC user manual — Matrix Switch hardware installation
Page 34 · click to enlarge
Page 34

2 • Hardware installation Model 6511RC User Manual

2. Inspect the rear of the chassis and verify that a cover plate is installed for each vacant module slot, and verify that each cover plate’s fasteners are tightened securely to the rear panel. Missing cover plates must be replaced before installing the Matrix Switch.

Matrix Switch hardware installation

Do the following to install the Matrix Switch hardware:

1. Remove the Matrix Switch rear blade from its shipping container.
2. Remove the slot cover plate, if present.
3. Unlatch both handles on the Matrix Switch blade by pressing in on the red release button in each handle (see figure 12 ).
4. While holding the Matrix Switch from the card handles (see figure 12 ), align the Matrix Switch with the guide rails of the appropriate slot and slide it back until it touches the backplane connectors and the alignment/ESD pin (see figure 12 ) engages the chassis. When the blade is fully seated, the red release buttons in the handles click up automatically, thus locking the handles.
Patton electronic 6511RC — Matrix Switch hardware installation diagram (page 34)
Fig. 13 · Matrix Switch hardware installation

Figure 12. Alignment/ESD pin and card handle

5. Tighten the screw fastener located inside each handle to secure the blade to the chassis.

34 Matrix Switch hardware installation

Page 35 of the Patton electronic 6511RC user manual — Installing the network cables
Page 35 · click to enlarge
Page 35

Model 6511RC User Manual 2 • Hardware installation

6. Insert the front blade into the front chassis slot corresponding to the slot in which you installed the rear blade. Verify that the release buttons in the handles click up to indicate that the board is fully seated and locked into place.

Installing the network cables

This section describes installing network interface cables on the following front and rear Matrix Switch blade ports:

  • The Matrix Switch front blade’s 10/100 Ethernet LAN port and an EIA 561 RS-232 CONFIG port (see figure 13 ).
  • The Matrix Switch rear blade’s STM-1 SDH WAN port (presented in SC optical and 75-ohm BNC electrical formats) and two 10/100/100 Ethernet WAN/LAN management ports (see figure 14 )
Patton electronic 6511RC — Installing the network cables diagram (page 35)
Fig. 14 · Installing the network cables

Figure 13. Matrix Switch front blade network interface ports

Patton electronic 6511RC — Installing the network cables diagram (page 35)
Fig. 15 · Installing the network cables

Figure 14. Matrix Switch rear blade network interface ports

Installing the network cables 35

Page 36 of the Patton electronic 6511RC user manual — Connecting the front-panel Ethernet LAN port
Page 36 · click to enlarge
Page 36

2 • Hardware installation Model 6511RC User Manual

Connecting the front-panel Ethernet LAN port The Matrix Switch includes a 10/100Base-T transceiver, accessible via a physical interface on the front panel of the front blade for connection to an Ethernet LAN. The Ethernet interface complies with IEEE 802.3 and is pre- sented on a 6-pin RJ-45 female receptacle. Once connected to a LAN, the Ethernet port will autosense the speed of the LAN and automatically negotiate half or full-duplex operation. This port provides access to the Matrix Switch’s resident management services, including the HTTP/Web Management feature. This port also connects to the on-board Ethernet Switch, thus providing Ethernet access to other blades within the ForeFront system via the PICMG 2.16 PSB. This section describes connecting the Matrix Switch to the Ethernet LAN via an Ethernet hub, switch, or workstation.

Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hub The 10/100Base-T Ethernet port (see figure 5) is designed to connect to an Ethernet switch or hub. The Ethernet RJ-45 pin and signal definitions for the Matrix Switch or for a NIC card in a workstation/PC are shown in figure 15. Connect a straight-through CAT-5 cable (one wired as shown in figure 15) between the Matrix Switch and the hub/switch.

Patton electronic 6511RC — Connecting the front-panel Ethernet LAN port diagram (page 36)
Fig. 16 · Connecting the front-panel Ethernet LAN port

Figure 15. Ethernet RJ-45 pin and signal definitions for Matrix Switch

Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PC The 10/100Base-T Ethernet port can connect to a single Ethernet-capable workstation or PC by means of a cross-over cable. Refer to figure 16 to assemble a cross-connect cable that will connect between the NIC Ether- net port in the workstation and the Matrix Switch 10/100Base-T Ethernet port.

Patton electronic 6511RC — Connecting the front-panel Ethernet LAN port diagram (page 36)
Fig. 17 · Connecting the front-panel Ethernet LAN port

Figure 16. Cross-over RJ-45-to-RJ-45 Ethernet cable diagram

36 Installing the network cables

Page 37 of the Patton electronic 6511RC user manual — Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)
Page 37 · click to enlarge
Page 37

Model 6511RC User Manual 2 • Hardware installation

Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured) Install the supplied RJ-45-to-RJ-45 cable with the DB9-RJ45 adapter between the Matrix Switch RS-232 port (see figure 13 on page 35) and an open serial port on your computer. If you need to assemble your own cable, refer to the pinout diagram in figure 17.

Patton electronic 6511RC — Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured) diagram (page 37)
Fig. 18 · Connecting the front-panel EIA-561 RS-232 configurat…

Figure 17. RJ-45 pin and signal definitions for Matrix Switch CONFIG port

Connecting the rear-panel STM-1 WAN port to an SDH network The Matrix Switch offers two types of STM-1 interfaces—optical and electrical—presented on the rear panel of the rear blade. Optical interfaces connect to fiber-optic network cables, while the electrical interfaces connect to coaxial network cables. The rear-blade connectors must match the type of network cables and connectors used by the SDH network to which you will connect.

Connecting the STM-1 optical interface to fiber-optic network cables The following versions of the Matrix Switch rear blade offer an optical interface for the STM-1 port

  • Model 6511RC/M155/SC20
  • Model /EBNC6511RC/M155/SC20

The designation SC20 in the model code denotes that an optical interface conforming to ITU specification G.957 and G.652 is present. The Matrix Switch presents the STM-1 optical interface on a pair of SC fiber- optic connectors, one for the transmiting (TX) and one for receiving (RX) signals (see figure 14 on page 35).

Installing the network cables 37

Page 38 of the Patton electronic 6511RC user manual — Connecting the STM-1 electrical interface to coaxial network cables
Page 38 · click to enlarge
Page 38

2 • Hardware installation Model 6511RC User Manual

Patton electronic 6511RC — Connecting the STM-1 electrical interface to coaxial network cables diagram (page 38)
Fig. 19 · Connecting the STM-1 electrical interface to coaxial…

Figure 18. Fiber-optic SC cable connectors

Do the following to connect the dual singlemode fiber-optic cable (see figure 18) to the STM-1 SC connectors: 1. Remove the protective cap from the fiber optic cable connectors.

2. Attach the transmit fiber-optic cable connector to the TX SC connector on the rear blade (see figure 14 on page 35).
3. Attach the receive fiber-optic cable connector to the RX SC connector on the rear blade.

Connecting the STM-1 electrical interface to coaxial network cables The Matrix Switch presents the STM-1 electrical interface on a pair of 75-ohm female BNC connectors, one for the transmiting (TX) and one for receiving (RX) signals (see figure 14 on page 35).

For most installations, the coaxial cable connecting the STM-1 WAN port to the SDH network can be no longer than 325 feet (100 meters).

38 Installing the network cables

Page 39 of the Patton electronic 6511RC user manual — Connecting the rear-panel Ethernet WAN/management ports
Page 39 · click to enlarge
Page 39

Model 6511RC User Manual 2 • Hardware installation

Figure 19. BNC coaxial cable connectors

Do the following to connect the dual 75-ohm coaxial cable (see figure 19) to the STM-1 BNC connectors:

1. Attach the transmit connector of the coaxial cable to the TX connector on the rear blade (see figure 14 on page 35).
2. Attach the transmit connector of the coaxial cable to the RX connector on the rear blade.

Connecting the rear-panel Ethernet WAN/management ports The Matrix Switch provides two 10/100/1000Base-T Ethernet transceivers, accessible via physical interfaces on the rear-panel of the rear blade, for connection to an external router, hub, or switch. Both interfaces are pre- sented on RJ-45 6-pin female receptacles. The interfaces comply with IEEE specification 802.3 and are labeled ENET 1 and ENET 2 (see figure 14 on page 35).

Once connected to a LAN, the Ethernet port will autosense the speed of the LAN and automatically negotiate half or full-duplex operation. The ports provide access to the Matrix Switch’s resident management services, including the HTTP/web management feature. This port also connects to the on-board Ethernet switch, thus providing Ethernet access to other blades within the ForeFront system via the PICMG 2.16 PSB.

You can use the two high-speed Ethernet ports to implement the following functions:

  • Ethernet trunks. You can connect the 10/100/100 Ethernet ports to a WAN router in order to deliver high-speed aggregated packet-based traffic to and from the ForeFront system over packet-switched WAN trunks. The WAN router would then be connected to a private WAN or to the Internet.
  • Ethernet management network. You can connect the 10/100/100 Ethernet ports to a local area network via an external hub or switch in order to implement an out-of-band management network. To create an external management network, all ForeFront blades must connect to the management LAN via an Ethernet port residing on each blade. The Matrix Switch also offers access to an internal management network, the PICMG 2.16 PSB. By means of its on-board Ethernet switch, the Matrix Switch provides a packet-switched path to all blades operating on the same PICMG 2.16 bus, which a Network Management System can use to communicate with the management services on those blades.

Installing the network cables 39

Page 40 of the Patton electronic 6511RC user manual — Completing the hardware installation
Page 40 · click to enlarge
Page 40

2 • Hardware installation Model 6511RC User Manual

Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switch The 10/100/100Base-T Ethernet ports may be connected to a WAN router, or to an Ethernet hub or switch. To connect the router, hub or switch to the Matrix Switch, you must use a straight-through CAT-5 RJ-45 cable (one wired as shown in figure 15 on page 36). Figure 15 shows the Ethernet RJ-45 pin and signal defi- nitions for the Matrix Switch. For cable distance limitations please consult the IEEE specification 802.3.

To connect the 10/100/100 Base-T Ethernet port to a router, hub or switch:

1. Connect the RJ-45 connector at one end of the cable into the 6-pin RJ-45 receptacle on the rear-panel of the 6511RC rear-blade.
2. Connect the RJ-45 connector at other end of the cable into the 6-pin RJ-45 receptacle on the router, hub, or switch.

Completing the hardware installation

This section verifies that the Matrix Switch hardware is operational to the point where you can begin configur- ing the software settings.

Power is delivered from the CPCI chassis backplane through the 47-pin PICMG 2.11 power connectors on the 6511RC blades. Upon insertion into the CPCI chassis, the Model 6511RC immediately powers up and begins its boot cycle. During the boot cycle the following should occur:

1. The POWER LED illuminates, indicating normal power is being applied to the 6511RC.
2. The green SYSTEM LED begins flashing, indicating the 6511RC is operating normally.

Hardware installation is now complete. To configure the 6511RC for operation, refer to chapter 3, “Configur- ing the Matrix Switch for operation” on page 41.

40 Completing the hardware installation

Page 41 of the Patton electronic 6511RC user manual — Table of contents
Page 41 · click to enlarge
Page 41

Table of contents

Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 42 of the Patton electronic 6511RC user manual — Configuration prerequisites
Page 42 · click to enlarge
Page 42

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Introduction

This chapter contains the following procedures that describe configuring the Model 6511RC Matrix Switch for operation:

  • “Configuration prerequisites” —lists the items you need to have on hand before configuring the Matrix Switch.
  • “Initial configuration through the RS-232 control port” on page 43—describes how to define the 6511RC’s LAN IP address and netmask parameters.
  • “Using a browser to complete Model 6511RC configuration” on page 47—describes how to define the remaining basic configuration parameters in order to bring your Matrix Switch on-line. The procedures include the following steps:

- Displaying the Matrix Switch home page (see “Displaying the Matrix Switch 6511RC web administra-

tion pages” on page 47)

- Defining the IP default gateway (see “Configuring the default gateway” on page 51)

- Defining the system clocking parameters (see “Configuring the system clocking parameters” on page 52

- Defining the STM-1 Circuit parameters (see “Configuring the SDH circuit parameters” on page 54)

- Enabling idle code generation for designated DS0 channels (see “Configuring DS0 idle codes” on

- Defining DS0 mappings within the STM-1 link (see “Selecting the SDH mapping path” on page 60)

  • “Saving your configuration” on page 74—describes how to save your configuration settings.
  • “Backing up your configuration parameters” on page 75—describes how save your configuration parameters to a file
  • “Completing the installation” on page 77—describes how to verify that your 6511RC Matrix Switch is fully operational.

Configuration prerequisites

You will need the following to configure the 6511RC Matrix Switch:

  • A PC equipped with the following:

- RS-232/V.24 serial port

- VT-100 terminal program, e.g., HyperTerminal

- Web browser (e.g., Netscape Communicator or Microsoft Internet Explorer)

  • You will need the following information to configure the Model 6511RC:

- The IP address and subnet mask for the 6511RC’s Ethernet port

- The IP address of the default gateway

  • To configure the STM-1 link, you will need the following information from the SDH network to which you are connecting:

page 58) · - Ethernet port · 42 Introduction

Page 43 of the Patton electronic 6511RC user manual — Initial configuration through the RS-232 control port
Page 43 · click to enlarge
Page 43

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

- Which E1 mapping path will be used within the STM-1 link, either AU3 or AU4.

- Section Trace Message Length

- The value of the JO byte for Section Trace Messages

- Path-1 Trace Message Length

- The value of the J1 byte for Path-1 Trace Messages

- The value of Path-1 Signal Label

- The E1 payload type, either asynchronous or byte synchronous

  • To configure the DS0 mappings, you will need

- a detailed plan describing the desired source and destination for each of the 4096 simplex DS0 channels

within the H.110 bus on the chassis mid-plane

- which DS0 channels within each E1 signal stream should carry an idle code

Initial configuration through the RS-232 control port

Initially you must configure the 6511RC’s IP address via the RS-232 Config port located on the Matrix Switch front frame. In rare instances, you may also need to change the netmask from the factory default value.

Connecting the DB9-RJ45 adapter with the included cable Do the following:

1. Find the DB9-RJ45 adapter for your PC and RJ-45-to-RJ45 cable shipped with your 6511RC Matrix Switch.
2. Connect the DB9-RJ45 adapter to your PC’s RS-232 serial port.
3. Connect the RJ45-RJ45 cable between the adapter that you installed in step 1 and the CONFIG port on the front of the Model 6511RC ( figure 20 ).

Figure 20. Model 6511RC interface ports

Initial configuration through the RS-232 control port 43

Page 44 of the Patton electronic 6511RC user manual — Setting up the HyperTerminal (or similar program) session
Page 44 · click to enlarge
Page 44

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Setting up the HyperTerminal (or similar program) session Do the following:

1. At your PC, find the file HYPERTRM.EXE . Open a HyperTerminal session by double-clicking on the file name.
Patton electronic 6511RC — Setting up the HyperTerminal (or similar program) session diagram (page 44)
Fig. 20 · Setting up the HyperTerminal (or similar program) se…

Figure 21. Connection Description window

2. Type a connection name (e.g., 6511RC Config ), select an icon, then click OK ( figure 22 ).
Patton electronic 6511RC — Setting up the HyperTerminal (or similar program) session diagram (page 44)
Fig. 21 · Setting up the HyperTerminal (or similar program) se…

Figure 22. Connect To window

3. On the Connect To window ( figure 22 ), set Connect using: to one of the options named Direct to ComX (where the “X” refers to the number identifying the RS-232 serial port on the PC). In the following procedure, Com1 will be the used as the port identifier.
4. Click OK .
5. The COM1 Properties window displays.

44 Initial configuration through the RS-232 control port

Page 45 of the Patton electronic 6511RC user manual — Setting up the HyperTerminal (or similar program) session
Page 45 · click to enlarge
Page 45

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

6. Configure your COM port settings as shown in figure 23 , then click OK .
Patton electronic 6511RC — Setting up the HyperTerminal (or similar program) session diagram (page 45)
Fig. 22 · Setting up the HyperTerminal (or similar program) se…

Figure 23. COM1 Properties window

7. Click on the File menu, then select Properties .
8. Configure the settings for Function, arrow and ctrl keys act as to Terminal keys as shown in figure 24 , then click OK .
Patton electronic 6511RC — Setting up the HyperTerminal (or similar program) session diagram (page 45)
Fig. 23 · Setting up the HyperTerminal (or similar program) se…

Figure 24. Terminal keys configuration

Initial configuration through the RS-232 control port 45

Page 46 of the Patton electronic 6511RC user manual — Setting up the HyperTerminal (or similar program) session
Page 46 · click to enlarge
Page 46

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

9. Connect the male end of the 6511RC Matrix Switch’s power cables to the power outlets.
10. Boot up information will display on your HyperTerminal connection window, eventually followed by a login request window (see figure 25 ).
Patton electronic 6511RC — Setting up the HyperTerminal (or similar program) session diagram (page 46)
Fig. 24 · Setting up the HyperTerminal (or similar program) se…

Figure 25. Login window

11. For the user name, type superuser .
12. For the password, type superuser ; the TOP LEVEL MANAGEMENT window then appears (see figure 26 ).
Patton electronic 6511RC — Setting up the HyperTerminal (or similar program) session diagram (page 46)
Fig. 25 · Setting up the HyperTerminal (or similar program) se…

Figure 26. VT-100 Top Level Management window

13. Type k for System, then press .
14. Under System, type 1 for Details, then press .
15. Enter g for LAN Address, then press .
16. Type your LAN IP address followed by pressing .
17. Press the left-arrow cursor key on your keyboard to return to the previous screen.
18. If you do not need to change the LAN Mask from the default of 255.255.255.0, go to step 21. Otherwise, press h and type the new LAN Mask in the same manner as when entering a LAN IP address.

46 Initial configuration through the RS-232 control port

Page 47 of the Patton electronic 6511RC user manual — Using a browser to complete Model 6511RC configuration
Page 47 · click to enlarge
Page 47

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

19. Press the left-arrow cursor key until the TOP LEVEL MANAGEMENT window displays.
20. Select a for Home , then press .
21. Under the Current Status page, type 1 ( store Config(1) ) to save the changes you have just made to the configuration.

This completes the initial configuration of the Model 6511RC. The next steps in configuration will be done using your web browser connected via Ethernet to the 6511RC.

Using a browser to complete Model 6511RC configuration

This section describes the following procedures:

  • Displaying the Matrix Switch home page (see section “Displaying the Matrix Switch 6511RC web administration pages” on page 47)
  • Defining the IP default gateway (see section “Configuring the default gateway” on page 51)
  • Defining the system clocking parameters (see section “Configuring the system clocking parameters” on page 52)
  • Defining the STM-1 Circuit parameters (see section “Configuring the SDH circuit parameters” on page 54)
  • Enabling idle code generation for designated DS0 channels (see section “Configuring DS0 idle codes” on page 58)
  • Defining DS0 mappings within the STM-1 link (see section “Selecting the SDH mapping path” on page 60)

Displaying the Matrix Switch 6511RC web administration pages Do the following:

1. Connect your PC’s Ethernet connection to the Ethernet LAN.
2. Connect the 6511RC’s Matrix Switch 10/100 Ethernet port to the Ethernet LAN.
3. At your PC, open a web browser session. In your browser’s URL/address field type the IP address of the Model 6511RC (for example, if the Model 6511RC’s IP address 123.124.221.10 , you would type 123.124.221.10 in the browser’s URL/address field). If you do not have an IP address in your TDAC, refer to “Initial configuration through the RS-232 control port” on page 43.
4. A login prompt will appear. In the username field type superuser then press to move the cursor to the Password field . In the password field type superuser then press .

Using a browser to complete Model 6511RC configuration 47

Page 48 of the Patton electronic 6511RC user manual — Using a browser to complete Model 6511RC configuration
Page 48 · click to enlarge
Page 48

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

5. The 3069RC Configuration Menu home page will appear (see figure 27 ).
Patton electronic 6511RC — Using a browser to complete Model 6511RC configuration diagram (page 48)
Fig. 26 · Using a browser to complete Model 6511RC configurati…

Figure 27. 6511RC Configuration Menu home page

48 Using a browser to complete Model 6511RC configuration

Page 49 of the Patton electronic 6511RC user manual — Home page overview
Page 49 · click to enlarge
Page 49

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Home page overview The HOME window is divided into two panes: the Configuration Menu pane and the Configuration/Informa- tion pane (see figure 28). The Configuration Menu contains the links to the various Model 6511RC sub- systems, while in the Configuration/Information pane, you can view status and other information or make changes to the system configuration. Unlike the Configuration Menu pane, which appears the same no matter which subsystem page you may select, the Configuration/Information pane contents will change as you move from one subsystem page to another.

Patton electronic 6511RC — Home page overview diagram (page 49)
Fig. 27 · Home page overview

Figure 28. HOME page window panes

Using a browser to complete Model 6511RC configuration 49

Page 50 of the Patton electronic 6511RC user manual — Home page overview
Page 50 · click to enlarge
Page 50

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Patton electronic 6511RC — Home page overview diagram (page 50)
Fig. 28 · Home page overview

Figure 29. Operator Actions buttons

From the Home page, the following actions can be performed:

  • Record Current Configuration —clicking on this button (see figure 29 ) saves the current configuration from volatile DRAM memory to FLASH memory. Once the configuration is saved into FLASH memory, the configuration will not be lost even if the power is cycled on the 6511RC. Initially, changes made to the 6511RC configuration are stored in volatile DRAM, enabling the user to set the box up with a working configuration before committing it to storage in FLASH. When you select Record Current Configuration , the 6511RC stores your changes to FLASH memory.
  • Hard Reset —this button (see figure 29 ) causes the Model 6511RC to perform a cold restart. When you select Hard Reset , the Matrix Switch confirms that you want to execute this command. Then, the Matrix Switch will disconnect all current sessions, re-initialize the interfaces, and re-load configuration parameters from FLASH.
  • Set Factory Default Configuration —this button (see figure 29 ) clears out the configuration in FLASH and loads the factory default parameters into FLASH memory. The factory default settings will not execute on the Model 6511RC until it is re-booted by doing a Hard Reset.

50 Using a browser to complete Model 6511RC configuration

Page 51 of the Patton electronic 6511RC user manual — Configuring the default gateway
Page 51 · click to enlarge
Page 51

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Configuring the default gateway The default gateway IP address, if defined, is used solely for managing the 6511RC remotely via the Ethernet port. The 6511RC does not transmit or receive user data nor any other traffic via the default gateway IP address or the Ethernet port.

Do the following to add the default gateway:

1. On the 6511RC Configuration Menu ( see figure 27 on page 48 ) , click the IP hyperlink to open the IP Overview page (see figure 30 ).
Patton electronic 6511RC — Configuring the default gateway diagram (page 51)
Fig. 29 · Configuring the default gateway

Figure 30. IP Overview page

2. Click the Routing Info hyperlink to open the IP Routing Overview page ( figure 31 ).
Patton electronic 6511RC — Configuring the default gateway diagram (page 51)
Fig. 30 · Configuring the default gateway

Figure 31. IP Routing Overview page

Using a browser to complete Model 6511RC configuration 51

Page 52 of the Patton electronic 6511RC user manual — Configuring the system clocking parameters
Page 52 · click to enlarge
Page 52

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

3. The Defined Routes table (see figure 32 ) will contain exactly one route, displayed in the first row of the table. The 6511RC created this route automatically when you defined the Ethernet IP address during Initial Configuration, earlier in this chapter. That first row displays the route and netmask for the primary IP address you defined for the Matrix Switch Ethernet interfaces.
Patton electronic 6511RC — Configuring the system clocking parameters diagram (page 52)
Fig. 31 · Configuring the system clocking parameters

Figure 32. Defined Routes table

4. You will use the first row in the Define a New Route table (see figure 33 ) to define the default gateway. The Destination field contains the value 0.0.0.0. Because the netmask for the default gateway is implied by the Matrix Switch’s primary IP address, the Mask field does not display. In the Gateway field, enter your 6511RC’s default gateway IP address.
Patton electronic 6511RC — Configuring the system clocking parameters diagram (page 52)
Fig. 32 · Configuring the system clocking parameters

Figure 33. Define a New Route table

5. Click the Define button (see figure 33 ) to activate the new default gateway address.

Configuring the system clocking parameters In this section you will define the system clocking configuration for the Matrix Switch. Three issues pertain to system clocking:

  • Module clocking mode —Will this Matrix Switch serve as a Master timing source for the other modules on the H.110 bus? (See section “Module clocking mode” for details.)
  • Module clocking source —What clock pulse will the Matrix Switch use for primary reference and alternate (fallback) reference . (See section “Module clocking source and fallback” on page 53 for details.)
  • Module clocking fallback —Will you enable or disable the clocking fallback feature in case the primary reference fails? (See section “Module clocking source and fallback” on page 53 for details.)

Module clocking mode Module clocking mode defines what role the Matrix Switch will assume on the H.110 bus with respect to sys- tem timing. You can select master(1), secondary(2), or slave(3) for the value of Clocking Mode. The master will drive the main reference clock for the chassis. Should the master fail, the secondary will drive the main refer-

52 Using a browser to complete Model 6511RC configuration

Page 53 of the Patton electronic 6511RC user manual — Module clocking source and fallback
Page 53 · click to enlarge
Page 53

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

ence. Slaves will not drive any clock reference. Most often the 6511RC will be defined as the master(1), while most other modules in the chassis will be defined as slave(3).

Module clocking source and fallback There are two module clocking source parameters, the primary reference and the fallback reference. Unless it fails or becomes disconnected, the primary reference provides the system clock for the 6511RC. Should this failure occur, the fallback reference will become the clocking source for the 6511RC’s system clock.You must choose one of the following values as the clocking source for each reference:

  • An internal oscillator
  • The STM-1 port
  • The system clock provided by the H.110 clocking master, (i.e. another module in the chassis).

The following examples illustrate how to define the system clocking parameters for two scenarios.

Example 1. In this example, your 6511RC will be the clocking master for all other modules on the same H.110 bus. Your 6511RC will derive its own timing from its STM-1 port as the main reference, and from its internal oscillator as the fallback reference. To define the system clocking parameters:

1. Connect a STM-1 WAN line to the 6511RC’s STM-1 port.
2. Click the System Clocking hyperlink on the 6511RC Configuration Menu (see figure 27 on page 48) to open the System Clocking Overview page (see figure 34 ).
Patton electronic 6511RC — Module clocking source and fallback diagram (page 53)
Fig. 33 · Module clocking source and fallback

Figure 34. System Clocking Overview page, example 1

3. For Module Clocking Mode, select master(1) from the drop-down menu.
4. Under Module Clocking Source , for Primary Reference select wan(602) from the drop-down menu .
5. For Fallback Reference select internal(200) from the drop-down menu.
6. Under Module Clocking Fallback , for Fallback Feature Desired State, s elect enable(1) .
7. Click the Modify button.

Using a browser to complete Model 6511RC configuration 53

Page 54 of the Patton electronic 6511RC user manual — Configuring the SDH circuit parameters
Page 54 · click to enlarge
Page 54

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Example 2. For this example, another Matrix Switch is the chassis is the clocking master, providing the system clock for the chassis, and your 6511RC is a slave. Your 6511RC will derive its timing from the H.110 bus sys- tem clock as the main reference, and from its STM-1 port as the fallback reference. To define the system clock- ing parameters:

1. Connect a STM-1 WAN line to the 6511RC’s STM-1 port.
2. Click the System Clocking hyperlink on the 6511RC Configuration Menu (see figure 27 on page 48) to open the System Clocking Overview page (see figure 35 ).
Patton electronic 6511RC — Configuring the SDH circuit parameters diagram (page 54)
Fig. 34 · Configuring the SDH circuit parameters

Figure 35. System Clocking Configuration page, example 2

3. For Module Clocking Mode, select slave(2) from the drop-down menu.
4. Under Module Clocking Source , for Primary Reference select system(600) from the drop-down menu .
5. For Fallback Reference select wan(602) from the drop-down menu.
6. Under Module Clocking Fallback , for Fallback Feature Desired State, s elect enable(1) .
7. Click the Modify button.

Configuring the SDH circuit parameters In order for the STM-1 link to function correctly, you must correctly define the values of certain configurable parameters that affect the SDH circuit. In order to configure the STM-1 link, you must first gather the follow- ing information:

  • Which E1 mapping path—either AU3 or AU4—will be used within the STM-1 link
  • Section trace message length
  • The value of the JO byte for section trace messages
  • Path-1 trace message length
  • The value of the J1 byte for path-1 trace messages
  • The value of path-1 signal label
  • The E1 payload type, either asynchronous or byte synchronous

54 Using a browser to complete Model 6511RC configuration

Page 55 of the Patton electronic 6511RC user manual — Accessing the SDH circuit parameters
Page 55 · click to enlarge
Page 55

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Accessing the SDH circuit parameters To access the SDH circuit parameters:

1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the SDH hyperlink to display the SDH Overview page (see figure 36 )
Patton electronic 6511RC — Accessing the SDH circuit parameters diagram (page 55)
Fig. 35 · Accessing the SDH circuit parameters

Figure 36. SDH Overview web management page

2. On the SDH Overview page, click the Configuration... hyperlink to display the SDH Modify page (see figure 37 ).
Patton electronic 6511RC — Accessing the SDH circuit parameters diagram (page 55)
Fig. 36 · Accessing the SDH circuit parameters

Figure 37. SDH Modify page

Using a browser to complete Model 6511RC configuration 55

Page 56 of the Patton electronic 6511RC user manual — Configuring the SDH physical interface type
Page 56 · click to enlarge
Page 56

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Configuring the SDH physical interface type Do the following to define the physical interface type providing the STM-1 link:

1. In the SDH Physical Configuration section (see figure 38 ), select from the Physical Interface drop-down menu the value that corresponds to the physical cabling attached to your STM-1 interface ports. If you are using fiber-optic cable connected to the rear-card SC connectors, then select optical(0). If you are using coaxial cables connected to the rear-card BNC connectors, then select electrical(1) .
Patton electronic 6511RC — Configuring the SDH physical interface type diagram (page 56)
Fig. 37 · Configuring the SDH physical interface type

Figure 38. SDH Physical Configuration section

2. Click the Submit button to activate your selection.

Configuring the SDH interface parameters 1. In the SDH Interface Configuration section (see figure 39), for Circuit Identifier, enter an optional alphanu- meric name for this STM-1 link.

Patton electronic 6511RC — Configuring the SDH physical interface type diagram (page 56)
Fig. 38 · Configuring the SDH physical interface type

Figure 39. SDH Interface Configuration section

2. If section trace is enabled in your connected SDH network, go to step 3. Otherwise, because section trace is disabled , for the Section Trace Monitor parameter, select sectionTraceDisable(0) from the dropdown menu, then go to step 7 to define the value of the SDH Payload Mapping parameter.
3. Because section trace is enabled in your connected SDH network, for the Section Trace Monitor parameter, select sectionTraceEnable(1) from the drop-down menu.
4. For the Section Trace message string , enter the alphanumeric string your connected SDH network uses for the section trace message string in the SDH frame.

56 Using a browser to complete Model 6511RC configuration

Page 57 of the Patton electronic 6511RC user manual — Configuring the SDH path trace parameters
Page 57 · click to enlarge
Page 57

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

ter applies. When the section trace message length is defined to be one byte, the Matrix Switch will ignore the value of Section Trace.

5. For Section Trace Msg Len, from the drop-down menu, select the value used by the SDH network your Matrix Switch is connected to: either 1, 16, or 64-byte trace messages.
6. For Section Trace J0 Byte enter the value your connected SDH network uses for the J0 byte in the SDH frame.
7. For SDH Payload Mapping, select the payload type corresponding to the way your connected SDH network maps the E1 payload into the SDH frame structure. Asynchronous E1 payload mapping is most common, so the factory default value on the Matrix Switch is stm1MappedAsynchE1(0). If your connected SDH network performs byte-synchronous E1 payload mapping, then select stm1MappedBytesynchE1(1) from the drop-down menu.
8. For Tx Payload Scramble, if your SDH network expects to receive a scrambled payload select SDHScrambleEnable(1) from the drop-down menu, otherwise select sdhScrambleDisable(0) .
9. For Rx Payload Scramble, if your SDH network transmits a scrambled payload select SDHScrambleEnable(1) from the drop-down menu, otherwise select sdhScrambleDisable(0) .
10. For SDH Mapping , select the type of AU corresponding to the SDH multiplexing path you desire. To multiplex seven TUG-2s into an AU-3, select au3Mapper(0) (the factory default) from the drop-down menu. To multiplex three TUG-3s into an AU-4, select au4Mapper(1) .
11. Click the Modify button to save your work into operating memory (volatile DRAM) and activate the new parameter values.

Configuring the SDH path trace parameters If you selected AU-4 mapping in the preceding procedure, the Matrix Switch will display one set of five parame- ters pertaining to Path 1. If you selected AU-3 mapping, the Matrix Switch will display three sets of five parame- ters each pertaining to Paths 1, 2, and 3. Do the following to define the values for the SDH path trace parameters:

1. If path trace is enabled in your connected SDH network, go to step 2. Otherwise, because path trace is disabled , in the SDH trace parameters table (see figure 40 ), for Path-1 Trace Monitor , select pathTraceDisable(0) from the drop-down menu. Refer to section “Configuring DS0 idle codes” on page 58 .
Patton electronic 6511RC — Configuring the SDH path trace parameters diagram (page 57)
Fig. 39 · Configuring the SDH path trace parameters

Figure 40. SDH Path Trace parameters

Using a browser to complete Model 6511RC configuration 57

Page 58 of the Patton electronic 6511RC user manual — Configuring DS0 idle codes
Page 58 · click to enlarge
Page 58

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

2. Because path trace is enabled in your connected SDH network, in the SDH trace parameters table (see figure 40 on page 57), for Path-1 Trace Monitor , select pathTraceEnable(1) from the drop-down menu.
3. For Path-1 Trace message, enter the alphanumeric string your connected SDH network uses for the path-1 trace message in the text box.
4. For Path-1 Trace Msg Len , select the value corresponding to the trace message length your connected SDH network uses.
5. For Path-1 Trace J1 Byte , enter the value your connected SDH network uses for the J1 byte in the SDH frame.
6. For Path-1 Signal Label , enter the value your connected SDH network uses for the path-1 signal label in the SDH frame.
7. If you have selected AU-3 mapping, repeat steps 1 through 6 to define values for the path-2 and path-3 trace parameters.
8. Click the Modify button to save your work into operating memory (volatile DRAM) and activate the new parameter values.

Configuring DS0 idle codes If you want your Matrix Switch to encode vacant DS0 channels with the standard E1 idle code (the hexadeci- mal value 7E), you must follow the procedures below to designate which DS0 channels within the STM-1 sig- nal stream should be so encoded. Obviously, in order to correctly define the idle code configuration, you must know which DS0 channels in the SDH frame are expected to be idle. Defining the idle code configuration involves two steps: you must first access the DS0 Idle Code Configuration web management page, then use that page to select the idle DS0 channels from the STM-1 structure and designate them as idle.

58 Using a browser to complete Model 6511RC configuration

Page 59 of the Patton electronic 6511RC user manual — Accessing the idle code configuration
Page 59 · click to enlarge
Page 59

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Accessing the idle code configuration Do the following to access the Matrix Switch’s idle code configuration:

1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the E1 Link hyperlink to display the E1 Link page (see figure 41 ).
Patton electronic 6511RC — Accessing the idle code configuration diagram (page 59)
Fig. 40 · Accessing the idle code configuration

Figure 41. E1 Link page

2. To view all of the 63 E1s within the STM-1 link, first ensure that:

– tug3ALL(0) is selected next to the label TUG3

– tug2ALL(0) is selected next to the label TUG2

then click the Submit Query button to display the next page showing E1 link status (see figure 42).

Patton electronic 6511RC — Accessing the idle code configuration diagram (page 59)
Fig. 41 · Accessing the idle code configuration

Figure 42. Page showing E1 link status

This page displays all 63 E1 links according to their position within the STM-1 mapping structure: each E1 resides within a tributary unit (TU), 3 TUs reside within each level-2 tributary unit group (TUG-2). The final level of multiplexing concentrates 7 TUG-2s within either a level-3 administrative unit group (AUG-3), or a level-3 tributary unit group (TUG-3). The TUG-3 then resides within a level-4 administra- tive unit group (AUG-4).

Using a browser to complete Model 6511RC configuration 59

Page 60 of the Patton electronic 6511RC user manual — Defining the DS0 idle code configuration
Page 60 · click to enlarge
Page 60

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

3. To access the DS0 Idle Code Configuration page for a selected E1, scroll right to view the DS0 configuration column, then click the blue diamond icon to display the SDH DS0 Idle Code Detail page (see figure 43 ) .
Patton electronic 6511RC — Defining the DS0 idle code configuration diagram (page 60)
Fig. 42 · Defining the DS0 idle code configuration

Figure 43. SDH DS0 Idle Code Detail page

Defining the DS0 idle code configuration The SDH DS0 Idle Code Detail page (see figure 43) displays a table for a selected E1, specified by the page title, within the STM-1 link. The table displays the value of the idle code parameter for each of the 32 DS0s within the specified E1 stream. To define the idle code configuration for the selected E1:

1. Find the DS0 number for which you want the Matrix Switch to generate an idle code.
2. Select the value enable(1) from the adjacent drop-down menu.
3. Repeat steps 1 and 2 for each DS0 for which you want to enable idle code generation.
4. Click the Modify button to save your work into operating memory (volatile DRAM) and activate your changes.

To complete the DS0 idle code configuration for the entire STM-1 link, you will ned to repeat the above pro- cedures for each E1 that you want to enable DS0 idle code generation for.

Selecting the SDH mapping path The Matrix Switch offers two options for the SDH mapping path: you can select the mapping path terminat- ing with TUG-2 and AU-3 or TUG-3 and AU-4.

60 Using a browser to complete Model 6511RC configuration

Page 61 of the Patton electronic 6511RC user manual — Defining the DS0 idle code configuration
Page 61 · click to enlarge
Page 61

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

The mapping path you select will determine which parameter fields the 6511RC will display on the DS0 Map- ping Overview page. You have already selected an SDH mapping type, but you may wish to double-check this value before mapping any DS0s, by doing the following:

1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the SDH hyperlink to open the SDH overview page (see figure 44 ).
Patton electronic 6511RC — Defining the DS0 idle code configuration diagram (page 61)
Fig. 43 · Defining the DS0 idle code configuration

Figure 44. SDH Overview page

2. At the top of the SDH Overview page, click the Configuration hyperlink to open the SDH Modify page (see figure 45 ).

Figure 45. SDH Modify page

Using a browser to complete Model 6511RC configuration 61

Page 62 of the Patton electronic 6511RC user manual — Defining DS0 mappings
Page 62 · click to enlarge
Page 62

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

3. Scroll down to the SDH mapping parameter and select the appropriate mapping path from the drop-down menu. Select au3Mapper(0) or au4Mapper(1). To multiplex seven TUG-2s into an AU-3, select au3Mapper(0) (the factory default) from the drop-down menu. To multiplex three TUG-3s into an AU-4, select au4Mapper(1) .
4. Click the Submit button to save changes.

You are now ready to define DS0 mappings.

Defining DS0 mappings In order for the STM-1 link to carry traffic through the Matrix Switch to and from the ForeFront system, you must define a set of DS0 mappings (correlations). You will define mappings between the full-duplex DS0s within the STM-1 link and the simplex DS0s within the H.110 bus. While it is not necessary to define a map- ping for every DS0 in the SDH link, only the mapped DS0s will carry user data. Unmapped DS0s may be con- figured to carry an idle code. Otherwise, unmapped DS0s will carry a random bit stream.

For each DS0 Mapping you define, you will create a correlation between a communications channel in the STM-1 link and a communications channel within the ForeFront chassis mid-plane. Each STM-1 channel consists of a set of full-duplex DS0s. Each midplane channel consists of two simplex sub-channels, transmitted and received. Each sub-channel consists of a set of simplex DS0s. You will define each STM-1 channel and each mid-plane sub-channel by specifying one or more timeslot numbers up to a maximum of 32 timeslots per channel. For a STM-1channel you will select up to 32 timeslot numbers from the range numbered 1 to 32. For a mid-plane channel you will select up to 32 timeslots from the range numbered 1 to 128.

On the STM-1 side, there are 63 E1 signal streams, each comprising 32 DS0s. Within an E1, each DS0 is a full-duplex channel, comprising a transmitted and a received signal stream. The STM-1 link comprises 2016 full-duplex DS0s.

On the mid-plane side, there are 4096 simplex DS0s within the H.110 bus, organized into 32 ports. Each H.110 port comprises 128 DS0s. Within the H.110 bus, each DS0 is a simplex signal stream, which the H.110 bus can either transmit or receive. You will define the direction of a mid-plane DS0 during the mapping process as either transmitting to the H.110 bus or receiving from the H.110 bus. The H.110 bus provides 4096 simplex DS0s.

When entering E1 and H.110 timeslot numbers, you must define the same number of timeslots on the SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that represents the timeslot numbers.

The following notation should be used for assigning timeslots:

  • dash: (-), e.g., 1-4
  • comma: (,), e.g., 1,4,9
  • combo: 1-2,3,6-7

62 Using a browser to complete Model 6511RC configuration

Page 63 of the Patton electronic 6511RC user manual — Defining DS0 mappings
Page 63 · click to enlarge
Page 63

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

The Matrix Switch offers two formats for defining DS0 mappings:

  • E1 port format —You will identify the 63 E1 signal streams within the STM-1 link using E1 port numbers 1-63. Those with little to moderate experience working with SDH network architecture will most likely find E1 format to be the simplest and most straightforward method for defining DS0 mappings. Refer to section “Defining DS0 mappings using E1 port format” on page 64.
  • TU format— You will identify an E1 signal stream according to its location within the STM-1 hierarchy, using the TU-12 number and TUG-2 number within an AUG-3 or within a TUG-3/AUG-4. Experienced SDH engineers with a clear understanding of STM-1 architecture will most likely prefer to use TU format to define DS0 mappings. Refer to section “Defining DS0 mappings using TU format” on page 69.

Figure 46 shows the position of each E1 port number within the STM-1 frame.

Patton electronic 6511RC — Defining DS0 mappings diagram (page 63)
Fig. 44 · Defining DS0 mappings

Figure 46. E1 Port numbers located within the STM-1 frame structure

The following sections describe how to define DS0 mappings.

Using a browser to complete Model 6511RC configuration 63

Page 64 of the Patton electronic 6511RC user manual — Defining DS0 mappings using E1 port format
Page 64 · click to enlarge
Page 64

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Patton electronic 6511RC — Defining DS0 mappings using E1 port format diagram (page 64)
Fig. 45 · Defining DS0 mappings using E1 port format

Figure 47. DS0 Mapping Overview page

Defining DS0 mappings using E1 port format For those with little to moderate experience in working with SDH network architecture, E1 format will most likely the simplest and most straightforward method for defining DS0 mappings. To define a DS0 mapping by E1 number, do the following:

1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the DS0 Mapping hyperlink to display the DS0 Mapping Overview page (see figure 47 ).
2. For the Display Option parameter, ensure that displayLongForm(0) is selected from the drop-down menu ( figure 47 ), then click the Modify button.
3. For the E1 Input Format parameter, select e1PortFormat(1) from the drop down menu, then click the adjacent Modify button.
4. In the Define a Mapping section, for E1 number, select the appropriate E1 port number from the dropdown menu .
5. For E1 Slots , type the timeslot numbers you wish to map to the H.110 bus.

When entering E1 and H.110 timeslot numbers you must define the same number of timeslots on the SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that repre- sents the timeslot numbers.

64 Using a browser to complete Model 6511RC configuration

Page 65 of the Patton electronic 6511RC user manual — Examples for configuring DS0 mappings.
Page 65 · click to enlarge
Page 65

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

The following notation should be used for assigning timeslots:

– dash(-), e.g., 1 – 4
– comma(,), e.g., 1,4,9
– combo1-2,3,6-7

At this point you have defined the SDH channel composed of a selected E1 signal stream and a set of timeslots within that E1. Now you must define the mid-plane channel to be correlated with the SDH channel.

6. In the first row, labeled to H110(5) , for the H.110 number, select the appropriate H.110 port number from the drop-down menu
7. In the first row, labeled toH110(5) , for H.110 slots, enter the timeslot numbers you wish to map to the H.110 bus ( from the E1).
8. In the second row, labeled fromH110(6), select the appropriate H.110 port number from the dropdown menu
9. In the second row, labeled fromH110(6), for H.110 slots, enter the timeslot numbers you wish to map from the H.110 bus ( to the E1).
10. Click the Define button. The new mapping will appear at the bottom of the page in the Defined Mappings table.
11. Examine the Defined Mappings table to verify that your new mapping appears and was correctly entered and recorded.

Examples for configuring DS0 mappings.

Three examples are provided:

  • Example 1— For E1 port number 1:

- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 1-32

- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 33-64

  • Example 2— For E1 port number 2:

- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 65-96

- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 97-128

  • Example 3— For E1 port number 7

- map all 32 timeslots of the E1 received signal to H.110 port 4 timeslots 1-32

- map all 32 timeslots of the E1 transmitted signal from H.110 port 4 timeslots 33-64

Using a browser to complete Model 6511RC configuration 65

Page 66 of the Patton electronic 6511RC user manual — Examples for configuring DS0 mappings.
Page 66 · click to enlarge
Page 66

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Map E1 Port 1 received, timeslots 1-32 to H.110 Port 1 timeslots 1-32.

Map E1 Port 1 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 33-64.

Solution:

1. Under E1 Number , select port1(1) from the drop-down menu (see figure 48 ) .
2. Under E1 Slots , enter 1-32 in the text box.
3. For toH110(5), u nder H.110 Number , select port1(1) from the drop-down menu .
4. For toH110(5), under H.110 slots , enter 1-32 in the text box.
5. For fromH110(5), u nder H.110 Number , select port1(1) from the drop-down menu .
6. For fromH110(5), under H.110 slots , enter 33-64 in the text box.
Patton electronic 6511RC — Examples for configuring DS0 mappings. diagram (page 66)
Fig. 46 · Examples for configuring DS0 mappings.

Figure 48. Define a mapping table for Example 1

7. Click the Define button.
8. Verify your new mapping appears in the Defined Mappings table (see figure 49 ).
Patton electronic 6511RC — Examples for configuring DS0 mappings. diagram (page 66)
Fig. 47 · Examples for configuring DS0 mappings.

Figure 49. Defined Mappings table for example 1

9. Examine the new mapping to verify that it was entered and recorded correctly.

You have completed the DS0 mapping procedure for example 1.

66 Using a browser to complete Model 6511RC configuration

Example 1

Page 67 of the Patton electronic 6511RC user manual — Examples for configuring DS0 mappings.
Page 67 · click to enlarge
Page 67

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Map E1 Port 2 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.

Map E1 Port 2 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 97-128.

Solution:

1. Under E1 Number , select port2(2) from the drop-down menu (see figure 50 ).
2. Under E1 Slots , enter 1-32 in the text box.
3. For toH110(5), under H.110 Number , select port1(1) from the drop-down menu .
4. For toH110(5), under H.110 slots , enter 65-96 in the text box.
5. For fromH110(5), under H.110 Number , select port1(1) from the drop-down menu .
6. For fromH110(5), under H.110 slots , enter 97-128 in the text box.
Patton electronic 6511RC — Examples for configuring DS0 mappings. diagram (page 67)
Fig. 48 · Examples for configuring DS0 mappings.

Figure 50. Define a Mapping table for example 2

7. Click the Define button.
8. Verify your new mapping appears in the Defined Mappings table (see figure 51 ).
Patton electronic 6511RC — Examples for configuring DS0 mappings. diagram (page 67)
Fig. 49 · Examples for configuring DS0 mappings.

Figure 51. Defined Mappings table for example 2

9. Examine the new mapping to verify that it was entered and recorded correctly.

You have completed the configuration for example 2.

Using a browser to complete Model 6511RC configuration 67

Example 2

Page 68 of the Patton electronic 6511RC user manual — Examples for configuring DS0 mappings.
Page 68 · click to enlarge
Page 68

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Map E1 Port 7 received, timeslots 1-32 to H.110 Port 4 timeslots 1-32.

Map E1 Port 7 transmitted, timeslots 1-32 from H.110 Port 4 timeslots 33-64.

Solution:

1. Under E1 Number , select port7(7) from the drop-down menu (see figure 52 ) .
2. Under E1 Slots , enter 1-32 in the text box.
3. For toH110(5), under H.110 Number , select port4(4) from the drop-down menu .
4. For toH110(5), under H.110 slots , enter 1-32 in the text box.
5. For fromH110(5), under H.110 Number , select port4(4) from the drop-down menu .
6. For fromH110(5), under H.110 slots , enter 33-64 in the text box.
Patton electronic 6511RC — Examples for configuring DS0 mappings. diagram (page 68)
Fig. 50 · Examples for configuring DS0 mappings.

Figure 52. Define a Mapping table for example 3

7. Click the Define button.
8. Verify your new mapping appears in the Defined Mappings table (see figure 53 ).
Patton electronic 6511RC — Examples for configuring DS0 mappings. diagram (page 68)
Fig. 51 · Examples for configuring DS0 mappings.

Figure 53. Defined Mappings table for example 3

9. Examine the new mapping to verify that it was entered and recorded correctly.

You have completed the configuration for example 3.

68 Using a browser to complete Model 6511RC configuration

Example 3

Page 69 of the Patton electronic 6511RC user manual — Defining DS0 mappings using TU format
Page 69 · click to enlarge
Page 69

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Defining DS0 mappings using TU format Experienced SDH engineers with a solid understanding of STM-1 architecture will most likely prefer to use TU format to define DS0 mappings. To define a DS0 mapping using TU format, do the following:

1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the DS0 Mapping hyperlink to display the DS0 Mapping Overview page (see figure 54 ).
2. For the Display Option parameter, verify that displayLongForm(0) is selected from the drop-down menu.
3. For the E1 Input Format parameter, select tuFormat(0) from the dropdown menu.
4. Click the Modify button to save changes.
Patton electronic 6511RC — Defining DS0 mappings using TU format diagram (page 69)
Fig. 52 · Defining DS0 mappings using TU format

Figure 54. DS0 Mapping Overview page with TU format selected

Using a browser to complete Model 6511RC configuration 69

Page 70 of the Patton electronic 6511RC user manual — Defining DS0 mappings using TU format
Page 70 · click to enlarge
Page 70

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Figure 55. E1 port numbers located within the STM-1 frame structure

5. The first three parameters in the Define a Mapping section (see figure 54 on page 69) specify an E1 signal stream within the STM-1 link. The STM-1 link contains either three TUG-3s or three AU-3s (see figure 55). In the Define a Mapping section, the first parameter name will vary depending on the mapping path you selected on the SDH configuration page. If you selected au3Mapper(0) then Au-3 will be dis- played. If you selected au4Mapper(1) then Tug-3 will be displayed. To define the value of the first map- ping parameter, select from the drop-down menu the AU-3 or TUG-3 number that contains the E1 you wish to map. The options for the value of AU-3 are:

The options for the value of TUG-3 are:

6. Each AU-4 or TUG-3 contains seven TUG-2s. To define the value of the TUG-2 parameter, select from the drop-down menu the TUG-2 number that contains the E1 you wish to map . The options for the value of TUG-2 are:

70 Using a browser to complete Model 6511RC configuration

Show 11 more labels / short text on this page
– au3-1(1) · – au3-2(2) · – au3-3(3) · – tug3-1(1) · – tug3-2(2) · – tug3-3(3) · – tug2-1(1) · – tug2-2(2) · – tug2-3(3) · – tug2-4(4) · – tug2-5(5)
Page 71 of the Patton electronic 6511RC user manual — Defining DS0 mappings using TU format
Page 71 · click to enlarge
Page 71

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

7. Each TUG-2 contains three TU-12s (which in turn contain one E1 each). To define the value of the TU12 parameter, select one of the following values from the drop-down menu:
8. The three parameters you defined above specify a selected E1 signal stream within the STM-1 link. For E1 Slots, enter the timeslot numbers within the selected E1 link that you wish to map to the H.110 bus.

When entering E1 and H.110 timeslot numbers you must define the same number of timeslots on the SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that repre- sents the timeslot numbers.

The following notation should be used for assigning timeslots:

– dash(-), e.g., 1–4
– comma(,), e.g., 1,4,9
– combo1-2,3,6-7

At this point you have defined the SDH channel composed of a selected E1 signal stream and a set of timeslots within that E1. Now you must define the mid-plane channel to be correlated with the SDH channel.

9. Under the heading Mid-plane Channel , in the first row, labeled to H110(5) , for H.110 number, select your desired H.110 port number from the drop-down menu.
10. In the first row, labeled toH110(5) , for H.110 slots, enter the timeslot numbers you wish to map to the H.110 bus ( from the E1).
11. In the second row, labeled fromH110(6), select your desired H.110 port number from the dropdown menu
12. In the second row, labeled fromH110(6), for H.110 slots, enter the timeslot numbers you wish to map from the H.110 bus ( to the E1).
13. Click the Define button. The new mapping will appear at the bottom of the page in the Defined Mappings table.
14. Examine the Defined Mappings table to verify that the new mapping appears and was correctly entered and recorded.

Using a browser to complete Model 6511RC configuration 71

Show 5 more labels / short text on this page
– tug2-6(6) · – tug2-7(7) · – tu12-1(1) · – tu12-2(2) · – tu12-3(3)
Page 72 of the Patton electronic 6511RC user manual — Examples for configuring DS0 mappings.
Page 72 · click to enlarge
Page 72

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Examples for configuring DS0 mappings.

Three examples are provided:

  • Example 1— For the E1 located in TUG-3 or AU-3 number 1, TUG-2 number 1, TU-12 number 1 (Matrix Switch E1 port number 1):

- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 1-32

- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 33-64

  • Example 2— For the E1 located in TUG-3 or AU-3 number 2, TUG-2 number 1, TU-12 number 1 (Matrix Switch E1 port number 2):

- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 65-96

- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 97-128

  • Example 3— For the E1 located in TUG-3 or AU-3 number 1 , TUG-2 number 1 , TU-12 number 3 (Matrix Switch E1 port number 7)

- map all 32 timeslots of the E1 received signal to H.110 port 4 timeslots 1-32

- map all 32 timeslots of the E1 transmitted signal from H.110 port 4 timeslots 33-64

Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 received, timeslots 1-32 to H.110 Port 1 timeslots 1-32.

Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 33-64.

Solution:

1. For the value of the first parameter under SDH Channel , select TUG3-1(1) or AU3-1(1) from the dropdown menu .
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu .
3. For the value of TU-12 select TU12-1(1) from the drop-down menu .
4. For the value of E1 Slots , enter 1-32 in the text box.
5. For toH110(5), under H.110 Number , select port1(1) from the drop-down menu .
6. For toH110(5), under H.110 slots , enter 1-32 in the text box.
7. For fromH110(5), under H.110 Number , select port1(1) from the drop-down menu .
8. For fromH110(5), under H.110 slots , enter 33-64 in the text box.
9. Click the Define button.
10. Verify that your new mapping appears in the Defined Mappings table.
11. Examine the new mapping to ensure it was entered and recorded correctly.

You have completed the DS0 mapping procedure for example 1.

72 Using a browser to complete Model 6511RC configuration

Example 1

Page 73 of the Patton electronic 6511RC user manual — Examples for configuring DS0 mappings.
Page 73 · click to enlarge
Page 73

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Map TUG-3 or AU-3 no. 2, TUG-2 no. 1, TU-12 no. 1 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.

Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 97-128.

Solution:

1. For the value of the first parameter under SDH Channel , select either TUG3-2(2) or AU3-2(2) from the drop-down menu .
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu .
3. For the value of TU-12 select TU12-1(1) from the drop-down menu .
4. Under E1 Slots , enter 1-32 in the text box.
5. For toH110(5), under H.110 Number , select port1(1) from the drop-down menu .
6. For toH110(5), under H.110 slots , enter 65-96 in the text box.
7. For fromH110(5), under H.110 Number , select port1(1) from the drop-down menu .
8. For fromH110(5), under H.110 slots , enter 97-128 in the text box.
9. Click the Define button.
10. Verify your new mapping appears in the Defined Mappings table.
11. Examine the new mapping to ensure it was entered and recorded correctly.

You have completed the configuration for example 2.

Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 received, timeslots 1 - 32 to H.110 Port 4 timeslots 1- 32.

Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 transmitted, timeslots 1 - 32 from H.110 Port 4 timeslots 33- 64.

Solution:

1. For the value of the first parameter under SDH Channel , select either TUG3-1(1) or AU3-1(1) from the drop-down menu .
2. For the value of TUG-2 select TUG2-1(1) from the drop-down menu .
3. For the value of TU-12 select TU12-3(3) from the drop-down menu .
4. Under E1 Slots , enter 1-32 in the text box.
5. For toH110(5), under H.110 Number , select port4(4) from the drop-down menu .
6. For toH110(5), under H.110 slots , enter 1-32 in the text box.
7. For fromH110(5), under H.110 Number , select port4(4) from the drop-down menu .
8. For fromH110(5), under H.110 slots , enter 33-64 in the text box.

Using a browser to complete Model 6511RC configuration 73

Example 2 · Example 3

Page 74 of the Patton electronic 6511RC user manual — Saving your configuration
Page 74 · click to enlarge
Page 74

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

9. Click the Define button.
10. Verify your new mapping appears in the Defined Mappings table.
11. Examine the new mapping to ensure it was entered and recorded correctly.

You have completed the configuration for example 3.

Saving your configuration At this point you have completed the basic configuration of your Matrix Switch for operation. To save your configuration settings in non-volatile RAM, do the following:

1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the HOME hyperlink to open the 6511RC Web Management Home page (see figure 56 ).

Figure 56. 6511RC Home page

2. Under Operator Actions Click the Record Current Configuration button (see figure 56 ).

74 Using a browser to complete Model 6511RC configuration

Page 75 of the Patton electronic 6511RC user manual — Backing up your configuration parameters
Page 75 · click to enlarge
Page 75

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Backing up your configuration parameters

The 6511RC Matrix Switch provides Import/Export functions that enable you to back up (export) and restore (import) your Matrix Switch’s configuration parameters against possible failure. Should your Matrix Switch ever need replacing, a previously saved copy of your (exported) configuration file can quickly be loaded (imported) into a replacement Matrix Switch.

To import or export a configuration, do the following:

1. On the 6511RC Configuration Menu (see figure 27 on page 48), click the Import/Export hyperlink to display the Import/Export page (see figure 57 ).
Patton electronic 6511RC — Backing up your configuration parameters diagram (page 75)
Fig. 53 · Backing up your configuration parameters

Figure 57. Import/Export page

Backing up your configuration parameters 75

Page 76 of the Patton electronic 6511RC user manual — Backing up the configuration store in flash memory
Page 76 · click to enlarge
Page 76

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Backing up the configuration store in flash memory To make a back-up copy of the configuration file currently stored in your Matrix Switch’s flash memory:

1. On the Import/Export page (see figure 57 on page 75) click the Export Flash... hyperlink. The Matrix Switch will get the configuration file currently stored in your Matrix Switch’s flash memory and display it in your browser (see figure 58 )
Patton electronic 6511RC — Backing up the configuration store in flash memory diagram (page 76)
Fig. 54 · Backing up the configuration store in flash memory

Figure 58. Example Matrix Switch flash memory configuration file displayed in a browser

76 Backing up your configuration parameters

Page 77 of the Patton electronic 6511RC user manual — Completing the installation
Page 77 · click to enlarge
Page 77

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

2. To save the displayed data as a text file, use your browser’s Save function (see figure 59 ). Using Netscape or Internet Explorer, for example, do the following:

– Click the File menu.

– Click Save As. A dialog box will appear. Use the dialog to save the data displayed on your browser (your

Matrix Switch configuration parameters) to a text file.

– Select the folder in which you want to store the file.

– Type a file name.

– Click Save.

Patton electronic 6511RC — Completing the installation diagram (page 77)
Fig. 55 · Completing the installation

Figure 59. Saving the access server flash memory configuration data as a text file

Completing the installation

This section verifies that the Model 6511RC is fully operational.

1. Perform a hard reset as follows:

– On the configuration menu, click the HOME hyperlink to display the Matrix Switch Home Page.

– Scroll down to Operator Actions buttons.

– Click the Hard Reset button.

2. Wait about ten seconds for the Matrix Switch to fully resume normal operation.
3. Verify the green POWER LED is lit. If the POWER LED is flashing green, refer to chapter 5, “Troubleshooting and maintenance” on page 81.
4. Verify that green SYSTEM LED is flashing to indicate the Model 6511RC system is operating normally.

Completing the installation 77

Page 78 of the Patton electronic 6511RC user manual — Completing the installation
Page 78 · click to enlarge
Page 78

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

5. Verify that the green WAN LED is illuminated, indicating that the Model 6511RCSTM-1 port is activated, is synchronized with the SDH network, and operating normally.

Note If the Matrix Switch does not behave as described, the most likely cause is that the Matrix Switch SDH parameters values for the STM- 1 link do not match those of the connected SDH network. To resolve this problem, double check the parameters on the Matrix Switch SDH Configuration page against those of the Connected SDH net- work, and correct any incorrect values.

6. There are three LEDs that indicate status for the Matrix Switch Ethernet subsystem. For information about interpreting the three Ethernet status LEDs, see table 3 on page 27.

Congratulations! Your Matrix Switch is now installed. If you require further information about configuring your Matrix Switch settings, refer to the Model 6511RC Matrix Switch Administrator’s Reference Guide available online at www.patton.com/manuals/6511RC-arg.pdf.

78 Completing the installation

Page 79 of the Patton electronic 6511RC user manual — Table of contents
Page 79 · click to enlarge
Page 79

Table of contents

Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 80 of the Patton electronic 6511RC user manual — De-activating the Model 6511RC
Page 80 · click to enlarge
Page 80

4 • Operation and shutdown Model 6511RC User Manual

Introduction

This chapter describes how to start up and power down the Model 6511RC.

Activating the Model 6511RC

The Model 6511RC is activated by completing the procedures in chapter 2, “Hardware installation” on page 31 and chapter 3, “Configuring the Matrix Switch for operation” on page 41. To activate the 6511RC, refer to the procedures in those chapters.

The Model 6511RC is designed for unattended operation. Once the Model 6511RC has been installed and configured, no further operator action is required under normal conditions.

De-activating the Model 6511RC

Perform the following procedure to deactivate the Model 6511RC.

1. Simultaneously press both red buttons on the front-panel handles of the 6511RC to unlock the handles and prepare the module for removal.
2. Simultaneously press both black handles outward and away from the center of the module to unseat the 6511RC from the mid-plane connectors.
3. Pull the handles to completely remove the Model 6511RC from the rack chassis. Place the module on an anti-static surface.
4. Repeat the above procedure to remove the rear module from the rack chassis. Place the blade on an antistatic surface.

80 Introduction

Page 81 of the Patton electronic 6511RC user manual — Table of contents
Page 81 · click to enlarge
Page 81

Table of contents

Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 82 of the Patton electronic 6511RC user manual — Troubleshooting during initial deployment
Page 82 · click to enlarge
Page 82

5 • Troubleshooting and maintenance Model 6511RC User Manual

Introduction

This chapter provides guidance to assist you when performing troubleshooting and fault analysis as a Matrix Switch operator. Should you require more information or technical assistance, refer to chapter 6, “Contacting Patton for assistance” on page 101.

Troubleshooting during initial deployment

The following table (see table 5) describes the symptoms for system faults that commonly occur when the Matrix Switch is first deployed, along with suggested remedies for each fault.

Table 5. Symptoms

POWER LED (green) is extinguished

To verify that power is being supplied to the Model 6511RC via the CPCI chassis power bus: verify that at least one chassis power supply module is installed in the chassis and functioning normally.

POWER LED (green) is flashing

The 6511RC has detected a power failure on a power bus. There may be a prob- lem with the CPCI chassis power system which feeds the Model 6511RC such as a failed power supply module in the chassis. The Model 6511RC will function nor- mally with one power supply. Inspect the power supplies in the CPCI chassis to identify and replace the failed power supply module. If no failed power supply is found, or if the POWER LED continues flashing, contact Patton Technical Support to determine if the Matrix Switch should be replaced.

CPU FAIL LED (red) is lit CPU is unable to load the software from FLASH to RAM for operation. As soon as

possible, remove the Model 6511RC from the CPCI chassis, wait 30 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disap- pears. If the CPU FAIL LED remains lit after the Model 6511RC completes the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch needs to be replaced.

ALARM LED (yellow) is lit or flashing

Indicates The 6511RC has detected a minor or major alarm condition. Examine the Alarm System Overview web management page to determine exactly which alarm(s) is(are) active.

Problem Corrective Action · 82 Introduction

Page 83 of the Patton electronic 6511RC user manual — General fault analysis
Page 83 · click to enlarge
Page 83

Model 6511RC User Manual 5 • Troubleshooting and maintenance

Table 5. Symptoms (Continued)

SYSTEM LED (green) is not flashing

The Model 6511RC is not functioning properly.

As soon as possible, force a module power cycle as follows:

1)Wearing an antistatic strap, simultaneously press both red buttons on the front- panel handles of the 6511RC to unlock the handles and prepare the module for removal.

2)Simultaneously press both black handles outward and away from the center of the module to unseat the 6511RC from the mid-plane connectors.

3. Wait 10 seconds.

4)Holding the module by the two black handles, very carefully push the module gently and firmly into the chassis until it is reseated against the midplane.

5)Press the black handle so that they click and lock closed.

Once the Matrix Switch has resumed operation re-inspect the SYSTEM LED. If the SYSTEM LED does not begin flashing after completing the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch should be replaced.

General fault analysis

The following procedures outline steps you should follow when troubleshooting a Model 6511RC malfunction.

1. If possible, talk to the person who reported the problem and obtain a detailed description of the symptoms. Create a written trouble report listing all the symptoms observed, including a complete description of the status for each LED indicator.
2. LED Status Indications and Recommended action s, table 6 provides information on interpreting LED status indicators along with recommended actions in response to each LED status indication. To correct the problem with your Matrix Switch, compare each LED status in your trouble report with the information in the table, and follow the recommend action for each LED.

Table 6. LED status indications and recommended actions

LED Location Color Status Meaning

Green On solid Power is being applied. No action recommended.

Flashing The 6511RC has detected a power failure on a power bus. There may

be a problem with the CPCI power supply system such as a failed power supply module in the chassis. The Model 6511RC will function normally with one power supply.

Inspect the power supplies in the CPCI chassis to identify and replace the failed power supply module. If the POWER LED continues flashing when all chassis power supplies are functional, contact Patton Technical Sup- port to determine if the Matrix Switch should be replaced.

Off No input power is being applied. Verify that at least one chassis power supply module is installed in the chassis and functioning normally.

General fault analysis 83

Problem Corrective Action · POWER Front panel

Page 84 of the Patton electronic 6511RC user manual — CLK SOURCE
Page 84 · click to enlarge
Page 84

5 • Troubleshooting and maintenance Model 6511RC User Manual

Table 6. LED status indications and recommended actions (Continued)

LED Location Color Status Meaning

CPU FAIL Front panel

Red On solid CPU is unable to load the software from FLASH to RAM for operation.

As soon as possible, remove the Model 6511RC from the CPCI chassis, wait 30 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disappears.

If the CPU FAIL LED remains lit after the Model 6511RC completes the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch needs to be replaced.

Off The CPU is operating normally. No action recommended.

Red On solid A minor alarm condition has been detected.

Flashing A major alarm condition has been detected.

Off The Model 6511RC is operating normally. No action recommended.

Green Flashing The Model 6511RC is operating normally. No action recommended.

The Model 6511RC is not functioning properly.

As soon as possible, remove the Model 6511RC from the CPCI chassis, wait 10 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disappears.

Once the Matrix Switch has resumed operation re-inspect the SYSTEM LED. If the SYSTEM LED does not begin flashing after completing the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch should be replaced.

ENET(NOD E)

Green Flash- ing or On solid

Indicates there is Ethernet frame activity on one or more of the 6511RC’s Ethernet interfaces, including the two rear-panel 10/100/1000 ports, the front -panel 10/100 port, and the packet--switched PICMG 2.16 bus. No action recommended

Off • Indicates NO Ethernet frame activity detected on any of the 6511RC’s Ethernet interfaces, including the PICMG 2.16 bus.

  • Verify that an Ethernet cable is plugged into the hub, switch, or workstation and the 10/100 Ethernet port on the front panel of the Model 6511RC.
  • Verify that the hub, switch, or workstation is powered on.
  • Verify that the correct straight-through or cross-over cable is being used, depending on whether you are connecting to a workstation (PC), hub, or switch.
  • Replace the cable. If the problem still exists, contact Patton Technical Support to determine if the Matrix Switch should be replaced.

CLK SOURCE

Green On solid The 6511RC is set as the Master Clock source.

No action recommended.

Flashing The 6511RC is set as the secondary clock source.

No action recommended.

Off The 6511RC is set as the slave, getting its clock from the H.110 Bus. No action recommended.

84 General fault analysis

Show 7 more labels / short text on this page
ALARM Front panel · SYSTEM Front panel · Off · or · On solid · Front panel · Front panel
Page 85 of the Patton electronic 6511RC user manual — ENET (SWITCH)
Page 85 · click to enlarge
Page 85

Model 6511RC User Manual 5 • Troubleshooting and maintenance

Table 6. LED status indications and recommended actions (Continued)

LED Location Color Status Meaning

CLK ERROR Front panel

Yellow On solid • Primary Reference clocking source has been lost and the 6511RC is using the Secondary Reference as its clocking source. Matrix Switch operation should continue unimpaired.

  • Visit the System Clocking Overview page and examine the current clocking configuration and status.
  • Use the clocking configuration and status information to determine the appropriate course of action to restore the Primary Reference clock source to operation.

Flashing • Master Clock source and the Secondary Clock source have been lost and the 6511RC is using its internal crystal for its clock. Matrix Switch operation should continue unimpaired.

  • Visit the System Clocking Overview page to examine the current clocking configuration and status.
  • Use the information in determined the appropriate course of action to restore the Primary Reference to operation.

Off No clock errors currently detected. No action recommended.

TEST MODE Front panel

Green On solid The STM-1 port is currently operating in some test mode.

No action recommended.

Off None of the G.SHDSL ports is operating in test mode. No action recommended.

WANa Front Panel

Green On solid Indicates the STM-1 port is activated, synched, and operating normally.

No action recommended.

Indicates that the Model 6511RC is detecting the SDH network, but is unable to synchronize with it.

  • Verify the STM-1 cables are fully and correctly connected.
  • Examine the SDH Configuration page and ensure each parameter value matches the corresponding value in the connected SDH network.

Off • Indicates rear module not present or STM-1 port is not configured.

  • Ensure rear module is incorrectly installed; install if absent.
  • Examine the SDH Configuration page and ensure each parameter value matches the corresponding value in the connected SDH network.

ENET (SWITCH)

Indicates there is Ethernet frame activity on at least one of the eight PICMG 2.16 connections to other blades on the PSB bus.No action recommended.

Off Indicates no Ethernet frame activity detected on the PICMG 2.16 bus. No action recommended.

Indicates Ethernet frame activity on one or both of the 10/100/1000 Ethernet ports. No action recommended

General fault analysis 85

Show 8 more labels / short text on this page
Single · Flash · Front Panel · Green Flashing · or On solid · ENET(REAR) Front Panel · Green Flashing · or On solid
Page 86 of the Patton electronic 6511RC user manual — Matrix Switch test tools
Page 86 · click to enlarge
Page 86

5 • Troubleshooting and maintenance Model 6511RC User Manual

Table 6. LED status indications and recommended actions (Continued)

LED Location Color Status Meaning

Off There is NO Ethernet frame activity on either of the 10/100/1000 Ethernet ports. No action recommended

Blue On Indicates module is ready for removal from cPCI chassis.

Off Indicates module NOT ready for removal from cPCI chassis. Do not remove card from chassis.

Yellow On solid A minor alarm condition has been detected.

Flashing A major alarm condition has been detected.

Off The Model 6511RC is operating normally. No action recommended.

Blue On Card ready for removal from cPCI chassis.

Off Card not ready for removal from cPCI chassis. Do not remove card from chassis.

ON LINE On Reserved for future use

Off Reserved for future use

10/100 ENET

Green On Ethernet Link is established

Integrated LEDs on RJ- 45 connec- tor

Off No Ethernet link is established

Yellow On Flashes to indicates Ethernet frame activity on this port

Off Indicates no Ethernet frame activity on this port

READY Blue On Card ready for removal from cPCI chassis.

Off Card not ready for removal from cPCI chassis.

a. This LED provides status indications for the STM-1 WAN link established via the optical or electrical ports on

the Rear Module of the 6511RC

Matrix Switch test tools

For the purpose of testing and troubleshooting the STM-1 link, the DS0 Mapping definitions, and H.110 bus connectivity, the Model 6511RC Matrix Switch offers the following tool sets:

  • Loopback test modes for the Matrix Switch STM-1 port
  • SDH Section Trace and SDH Path Trace functions for the STM-1 link

The following sections describe these tool sets in detail.

Loopback test modes for the STM-1 port The Matrix Switch provides the following diagnostic loopback test modes for the STM-1 port:

  • SDH facility loop (see section “Facility Loop [sonetFacilityLoop(1)]” on page 87)
  • SDH terminal loop (see section “Terminal loop [sonetTerminalLoop(2)]” on page 88)
  • H.110 loop (see section “Other Loop [sonetOtherLoop(3)]” on page 90)

The facility and terminal loops are specified by the SDH protocol. The H.110 loop is proprietary to the Fore- Front Matrix Switch, and fulfills the SDH specification for a third vendor-defined loop.

86 Matrix Switch test tools

Show 4 more labels / short text on this page
READY Front panel · ALARM Rear blade · READY Rear blade · Front Panel
Page 87 of the Patton electronic 6511RC user manual — Facility Loop [sonetFacilityLoop(1)]
Page 87 · click to enlarge
Page 87

Model 6511RC User Manual 5 • Troubleshooting and maintenance

To understand how these test modes work, you must first understand the basic architecture of the Model 6511RC’s TDM mapping functions. The TDM mapping function provides the connection between the STM-1 port and the H.110 bus. Within the TDM mapper (see figure 60) data passes between the SDH fram- ing processor and the H.110 framing processor.

H.110 bus STM-1 port

H.110 Framer

Model 6511RC Matrix Switch

Figure 60. Matrix Switch TDM mapping architecture

The various loopback test modes route data through one or both of these framing processors, with the data path making a U-turn in one framer or the other. Subsequent paragraphs describe the details of each loopback test mode for the STM-1 port.

Facility Loop [sonetFacilityLoop(1)] You can use the facility loop to test and troubleshoot the operation of the STM-1 link, including the Matrix Switch’s STM-1 port and the fiber-optic or coaxial cables connected to it.

The facility loop (see figure 61) returns data received from the SDH facility (the STM-1 link) back to the same SDH facility. In other words, when the Facility Loop is activated, the Matrix Switch receives data from the STM-1 link and transmits the (unmodified) data back to the STM-1 link.

The U-turn for the facility loop occurs within the SDH framer on the Matrix Switch. The data path for the facility loop traverses the SDH framer, but not the H.110 framer. Data enters the Matrix Switch at the STM-1 receive port, and enters the SDH framer where it loops back toward the STM-1 link, leaving the Matrix switch at the STM-1 transmit port.

Figure 61. Facility Loopback test mode

To activate the facility loopback test mode:

1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.

Matrix Switch test tools 87

Show 6 more labels / short text on this page
TDM Mapper · Tx · Rx · SDH Framer · Rx · Tx
Page 88 of the Patton electronic 6511RC user manual — Terminal loop [sonetTerminalLoop(2)]
Page 88 · click to enlarge
Page 88

5 • Troubleshooting and maintenance Model 6511RC User Manual

2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration page (see figure 62 ).
Patton electronic 6511RC — Terminal loop [sonetTerminalLoop(2)] diagram (page 88)
Fig. 56 · Terminal loop [sonetTerminalLoop(2)]

Figure 62. SDH Configuration page with sonetFacilityLoop(1) selected

3. Scroll down to the Loopback parameter in the SDH Interface Configuration table.
4. From the drop-down menu, select sonet(facilityLoop(1) .
5. Click the first Submit button located just below the SDH Interface Parameters table.

To deactivate the Facility Loopback test mode, from the LoopBack parameter drop-down menu, select sonet- NoLoop(0) and click the Submit button.

Terminal loop [sonetTerminalLoop(2)] The terminal loop (see figure 63) returns data received from the SDH terminals back to those SDH terminals (other ForeFront modules on the same H.110 bus). In other words, when the Terminal Loop is activated, the Matrix Switch receives data from other ForeFront modules via the H.110 bus and transmits the (unmodified) data back to those same modules (via the H.110 bus).

The U-turn for the terminal loop occurs within the SDH framer on the Matrix Switch. The data path for the terminal loop traverses both the H.110 framer and the SDH framer. Data transmitted by the SDH terminals (other ForeFront modules) enters the Matrix Switch from the H.110 bus through the mid-plane

Figure 63. Terminal loopback test mode

88 Matrix Switch test tools

Page 89 of the Patton electronic 6511RC user manual — Terminal loop [sonetTerminalLoop(2)]
Page 89 · click to enlarge
Page 89

Model 6511RC User Manual 5 • Troubleshooting and maintenance

connections. The data passes through the H.110 framer, then traverses the SDH framer where it loops back, passing through the H.110 framer again. The data leaves the Matrix switch through its mid-plane connections and returns via the H.110 bus to the sending SDH terminals (other ForeFront modules).

The terminal loop affects only those DS0s that are mapped from the H.110 bus to the STM-1 link or from the STM-1 link to the H.110 bus. Likewise, the loop affects only those ForeFront modules included in one or more such DS0 mappings.

The terminal loop exercises the physical and logical connections between the Matrix Switch and the other ForeFront modules connected to the same H.110 bus (its SDH terminals). You can use the terminal loop to test and troubleshoot the DS0 mappings you have defined while simultaneously testing H.110 bus connectiv- ity with other ForeFront modules via the chassis mid-plane.

To activate the Terminal Loop test mode:

1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.
2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration page (see figure 64 ).
3. Scroll down to the Loopback parameter in the SDH Interface Configuration table.
4. From the drop-down menu, select sonetTerminalLoop(2).
5. Click the first Submit button located just below the SDH Interface Parameters table.
Patton electronic 6511RC — Terminal loop [sonetTerminalLoop(2)] diagram (page 89)
Fig. 57 · Terminal loop [sonetTerminalLoop(2)]

Figure 64. SDH Configuration page with sonetTerminalLoop(2) selected

To deactivate the terminal loop test mode, from the LoopBack parameter drop-down menu, select sonet- NoLoop(0) and click the Submit button.

Matrix Switch test tools 89

Page 90 of the Patton electronic 6511RC user manual — Other Loop [sonetOtherLoop(3)]
Page 90 · click to enlarge
Page 90

5 • Troubleshooting and maintenance Model 6511RC User Manual

Other Loop [sonetOtherLoop(3)] The other loop [sonetOtherLoop(3)] operates much like the facility loop, however the data enters the H.110 framer where it makes a U-turn. The Other Loop test mode (See figure 65) is a factory debugging and hardware test tool intended for use by Patton engineering. The terminal loop and facility loop provide all the functional- ity a Matrix Switch operator should require. Though it is available to Matrix Switch operators, the Other Loop test mode offers no further advantage for testing or troubleshooting in the field.

Figure 65. Other Loopback test mode

SDH section trace and path trace The Matrix Switch supports the section trace and path trace functions specified in the SDH protocol. You can use these trace functions to verify connectivity across an SDH circuit or circuit segment and to validate the link is operating properly. When a trace is enabled, two SDH devices pass a trace message to each other across an SDH link or link segment. When the message arrives without errors the trace succeeds, indicating the connec- tion is healthy. If a device receives a trace message that does not match the expected value, a trace mismatch occurs, indicating an error in the connection.

90 Matrix Switch test tools

Page 91 of the Patton electronic 6511RC user manual — Sections and paths
Page 91 · click to enlarge
Page 91

Model 6511RC User Manual 5 • Troubleshooting and maintenance

Sections and paths Between a pair of SDH multiplexers, an SDH circuit may comprise multiple cable segments connected by intermediate devices such as signal repeaters and add-drop multiplexers (see figure 66). A cable segment with a regenerator at one or both endpoints is called a section. A set of cable segments with an add-drop multiplexer at one or both endpoints is called a line. An SDH circuit with full-service multiplexers at both endpoints is called a path.

Patton electronic 6511RC — Sections and paths diagram (page 91)
Fig. 58 · Sections and paths

Figure 66. Section, path, and line within an SDH circuit

Section trace The section trace function verifies section connectivity between the two section-terminating nodes.Two SDH section-terminating devices perform the section trace over the STM-1 media segment between them. When section trace is enabled, the SDH frame carries a trace message in either the J0 byte or the section trace string. The value you define for Section Trace Message Length determines which field will carry the Section Trace Mes- sage, as specified below:

  • 1-byte section trace message length — Use the J0 byte for trace messaging, and ignore the contents of section trace string. The value of J0 may be any positive integer in the range of 0 to 255.
  • 16-byte section trace message length — Use the section trace string for section trace messaging , and ignore the contents of J0. The value of section trace string may be any alphanumeric text string up to 15 characters long. The 16-byte field includes CRC-7 in the 16th byte.
  • 64-byte section trace message length — Use the section trace string for section trace messaging , and ignore the contents of J0. The value of section trace string may be any alphanumeric text string up to 64 characters long. The 64-byte section trace string does not include any CRC.

To enable section trace:

1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.
2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration page (see figure 67 ).

Matrix Switch test tools 91

Page 92 of the Patton electronic 6511RC user manual — Path trace
Page 92 · click to enlarge
Page 92

5 • Troubleshooting and maintenance Model 6511RC User Manual

Patton electronic 6511RC — Path trace diagram (page 92)
Fig. 59 · Path trace

Figure 67. Section Trace parameters on the SDH Configuration page

3. For Section Trace Monitor, select sectionTraceEnable(1) from the drop-down menu .
4. For the Section Trace message string , enter the alphanumeric string your connected SDH network uses for the Section Trace Message String in the SDH frame.
5. For Section Trace Msg Len, from the drop-down menu, select the value used by the SDH network your Matrix Switch is connected to: either 1, 16, or 64-byte trace messages.
6. For Section Trace J0 Byte enter the value your connected SDH network uses for the J0 byte in the SDH frame.
7. Click the Submit button to save your work into operating memory (volatile DRAM) and activate the new parameter values.

Path trace The path trace function verifies path connectivity between the two path-terminating nodes.The two SDH path-terminating devices perform the trace over the STM-1 media segment between them. When Path Trace is enabled, the SDH frame carries the Path Trace message in either the J1 byte or the path trace string. The value you define for Path Trace Message Length determines which field will carry the Path Trace message, as specified below:

  • 1-byte Trace Message Length — use the J1 byte for trace messaging, and ignore the contents of path trace string. The value of J0 may be any positive integer in the range of 0 to 255.
  • 16-byte Trace Message Length — use the path trace string for path trace messaging , and ignore the contents of J1. The value of path trace string may be any alphanumeric text string up to 15 characters long. The 16-byte field includes CRC-7 in the 16th byte.

92 Matrix Switch test tools

Page 93 of the Patton electronic 6511RC user manual — Number of paths per frame
Page 93 · click to enlarge
Page 93

Model 6511RC User Manual 5 • Troubleshooting and maintenance

  • 64-byte Trace Message Length — use the section trace string for section trace messaging , and ignore the contents of J1. The value of section trace string may be any alphanumeric text string up to 64 characters long. The 64-byte field does not include any CRC.

Number of paths per frame The STM-1 frame can support one path or three paths, depending on how the STM-1 signal is mapped.

  • AU-4 mapping — Using AU-4 mapping the STM-1 frame supports a single path. When you select AU-4 mapping for the value of the SDH Mapping parameter, the Matrix Switch displays only the Path-1 Trace parameters.
  • AU-3 mapping — Using AU-3 mapping the STM-1 frame supports three paths. Each of the three AU-3s in the STM-1 frame represents a separate path. When you select AU-3 mapping for the value of the SDH Mapping parameter, the Matrix Switch displays the path trace parameters for each of the three paths. Path-1, Path-2, and Path-3 (one path trace for each AU-3 in the STM-1 frame).

To enable path trace:

1. On the configuration menu, click the SDH hyperlink to display the SDH Overview page.
2. At the top of the SDH Overview page, click the Configuration hyperlink to display the SDH Configuration page (see figure 68 ).
Patton electronic 6511RC — Number of paths per frame diagram (page 93)
Fig. 60 · Number of paths per frame

Figure 68. Path Trace parameters on the SDH Configuration page

3. In the SDH Trace Parameters table, for Path-1 Trace Monitor , select pathTraceEnable(1) from the dropdown menu.
4. For Path-1 Trace message string, enter the alphanumeric string your connected SDH network uses for the path-1 trace message in the text box.

Matrix Switch test tools 93

Page 94 of the Patton electronic 6511RC user manual — Maintenance
Page 94 · click to enlarge
Page 94

5 • Troubleshooting and maintenance Model 6511RC User Manual

5. For Path-1 Trace Msg Len , select the value corresponding to the trace message length your connected SDH network uses.
6. For Path-1 Trace J1 Byte , enter the value your connected SDH network uses for the J1 byte in the SDH frame.
7. For Path-1 Signal Label , enter the value your connected SDH network uses for the path-1 signal label in the SDH frame.
8. If you have selected AU-3 mapping, repeat steps 3 through 7 to define values for the Path-2 and Path-3 trace parameters.
9. Click the Submit button to save your work into operating memory (volatile DRAM) and activate the new parameter values.

Periodic maintenance

Consult the rack chassis user manual for information on preventative maintenance (such as cleaning the chassis air cooling vents to remove accumulated dust).

Calibration The Model 6511RC requires no calibration.

Maintenance

This section describes replacing the Model 6511RC.

Replacing the Model 6511RC If you isolate a problem to the a Model 6511RC component, the entire Model 6511RC must be replaced as described in the follow section.

Exporting the current Model 6511RC configuration The 6511RC Matrix Switch provides Import/Export functions. These functions enable you to back up (export) and restore (import) your Matrix Switch’s configuration parameters against possible failure. Should your Matrix Switch ever need replacing, a previously saved copy of your (exported) configuration file can quickly be loaded (imported) into a replacement Matrix Switch.

94 Periodic maintenance

Page 95 of the Patton electronic 6511RC user manual — Periodic maintenance
Page 95 · click to enlarge
Page 95

Model 6511RC User Manual 5 • Troubleshooting and maintenance

1. If you already have an exported backup copy of your current configuration, go to “Removing the defective Model 6511RC” on page 97. Otherwise, go to step 2.
2. On the Configuration Menu pane, click the Import/Export hyperlink to display the Import/Export page ( figure 69 ).
Patton electronic 6511RC — Periodic maintenance diagram (page 95)
Fig. 61 · Periodic maintenance

Figure 69. Import/Export page

Maintenance 95

Page 96 of the Patton electronic 6511RC user manual — Periodic maintenance
Page 96 · click to enlarge
Page 96

5 • Troubleshooting and maintenance Model 6511RC User Manual

3. To make a back-up copy of the configuration file currently stored in your Matrix Switch’s flash memory:

– On the Import/Export page (figure 69 on page 95) click the Export Flash... hyperlink. The Matrix

Switch will get the configuration file currently stored in your Matrix Switch’s flash memory and display it in your browser (figure 70)

Figure 70. Example Matrix Switch flash memory configuration file displayed in a browser

96 Maintenance

Page 97 of the Patton electronic 6511RC user manual — Removing the defective Model 6511RC
Page 97 · click to enlarge
Page 97

Model 6511RC User Manual 5 • Troubleshooting and maintenance

– To save the displayed data as a text file, use your browser’s Save function (see figure 71). Using Netscape

or Internet Explorer, for example.

  • Click the File menu.
  • Click Save As . A dialog box will appear. Use the dialog to save the data displayed on your browser (your Matrix Switch configuration parameters) to a text file.
  • Select the folder in which you want to store the file,
  • Type a file name.
  • Click Save .

Figure 71. Saving the access server flash memory configuration data as a text file

Removing the defective Model 6511RC 1. Remove the replacement Model 6511RC from its shipping container and place it near the chassis in which the malfunctioning Model 6511RC is located.

2. Disconnect and label the following cables from the malfunctioning Model 6511RC:

– The STM-1 WAN cable

– The RS-232 CONFIG cable (if installed)

– The 10/100 Ethernet cable (if installed)

– The two 10/100/1000 Ethernet cables (if installed)

Maintenance 97

Page 98 of the Patton electronic 6511RC user manual — Installing the replacement Model 6511RC
Page 98 · click to enlarge
Page 98

5 • Troubleshooting and maintenance Model 6511RC User Manual

3. Simultaneously press both red buttons on the front-panel handles of the 6511RC to unlock the handles and prepare the module for removal.
4. Simultaneously press both black handles outward and away from the center of the module to unseat the 6511RC from the mid-plane connectors.
5. Pull the handles gently and firmly to completely remove the Model 6511RC from the rack chassis. Place the module on an anti-static surface.
6. Repeat the above procedure to remove the rear module from the rack chassis. Place the rear module on an anti-static surface.
7. Place the removed modules in the container the replacement Model 6511RC came in so you can return the defective Model 6511RC for repair.

Installing the replacement Model 6511RC 1. Insert the replacement Model 6511RC into the rack chassis.

2. Insert the rear blade into the desired slot in the rack chassis. Make sure the blade is seated properly in the slot guides.
3. Gently press the blade into the chassis until the alignment/ESD pin engages the chassis. When the blade is fully seated, the red buttons in the handles click up automatically, thus locking the handle and activating the switch (closed position). The click of the button gives a visual and audible confirmation that the board is fully seated.
4. Connect the following cables to the Model 6511RC:

– The STM-1 WAN cable

– The RS-232 CONFIG cable

– The 10/100 Ethernet cable

– The two 10/100/1000 Ethernet cables (if used)

5. Verify that the green POWER LED is lit.

Importing a saved configuration Before importing a saved configuration, you must define the Model 6511RC’s IP address and netmask. These parameters are defined via the Model 6511RC RS-232 CONFIG port on the Model 6511RC.

1. Refer to chapter 3, “Configuring the Matrix Switch for operation” on page 41 and follow the procedures contained in section “Initial configuration through the RS-232 control port” on page 43.
2. To import a saved configuration, connect your Web browser to the Administration Pages, then click on Import/Export under the Configuration Menu to display the Import/Export page ( figure 69 on page 95).
3. To import a configuration file into the Model 6511RC, type the complete path and filename for the configuration file you wish to load or click on the Browse… button to select the desired file, then click the Submit Query button.

98 Maintenance

Page 99 of the Patton electronic 6511RC user manual — Completing the installation
Page 99 · click to enlarge
Page 99

Model 6511RC User Manual 5 • Troubleshooting and maintenance

Upon successfully importing the file, the Model 6511RC will display Configuration Load Complete, indi- cating that the new operating parameters have been loaded into flash memory.

4. On the Configuration Menu, click the HOME hyperlink, then click the Hard Reset button under Operator Actions .

Completing the installation This section verifies that the Model 6511RC is fully operational.

1. Verify that the green POWER LED is lit. If the POWER LED is flashing green, refer to Chapter 5, “Troubleshooting and maintenance”.
2. Verify that the WAN LED illuminates, indicating that the Model 6511RC is synchronizing with the T1/E1 signal.
3. Verify that after 5 seconds, the WAN LED begins flashing, indicating that the Model 6511RC is satisfied with the quality of the T1/E1 signal.
4. Verify that after 10 seconds, the WAN LED extinguishes, indicating that the Model 6511RC is satisfied with the network signal and that the link is ready for use.
5. Verify that the green Ethernet LED is either flashing (indicating link status is nominal for the front Ethernet port) or on solid (indicating that link status is nominal for at least one of the Ethernet backplane connections).

The Model 6511RC is operational.

Maintenance 99

Page 100 of the Patton electronic 6511RC user manual — Completing the installation
Page 100 · click to enlarge
Page 100

5 • Troubleshooting and maintenance Model 6511RC User Manual

100 Maintenance

Page 101 of the Patton electronic 6511RC user manual — Table of contents
Page 101 · click to enlarge
Page 101

Table of contents

Contentsp.3Compliance Informationp.7Radio and TV Interferencep.7Industry Canada Noticep.7FCC Part 68 (ACTA) Statementp.7CE Noticep.8About this guidep.9Audiencep.9Structurep.9Precautionsp.10Typographical conventions used in this documentp.10General conventionsp.10Mouse conventionsp.11Chapter 1 Introductionp.13Model 6511RC Matrix Switch overviewp.14Hardware overviewp.16ForeFront chassis architecturesp.19ForeFront Model 6476 6U cPCI chassisp.19The ForeFront Model 6676 9U chassisp.20Matrix Switch functionalityp.21TDM mapping and aggregationp.21TDM bus architecturep.22STM-1 link architecturep.22Matrix Switch TDM capacityp.23Matrix Switch Ethernet Switchingp.23Managementp.24Management Servicesp.24Management Interfacesp.24Management Approachp.24Matrix Switch Interfacesp.25WAN Interfacesp.25Mid-Plane Interfacesp.25LAN Interfacep.25RS-232 Config portp.26Power systemp.26Central processing unitp.26System timingp.26Clocking Modep.26Clocking Sourcep.26Temperaturep.27Altitudep.27Humidityp.27Physical dimensionsp.27LED Indicatorsp.27Approvalsp.29Chapter 2 Hardware installationp.31Introductionp.32Unpacking the Model 6511RC Matrix Switchp.32Verifying that the ForeFront chassis is properly installedp.32Verfying correct electrical groundingp.33Verifying correct cover plate installationp.33Matrix Switch hardware installationp.34Installing the network cablesp.35Connecting the front-panel Ethernet LAN portp.36Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hubp.36Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PCp.36Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured)p.37Connecting the rear-panel STM-1 WAN port to an SDH networkp.37Connecting the STM-1 optical interface to fiber-optic network cablesp.37Connecting the STM-1 electrical interface to coaxial network cablesp.38Connecting the rear-panel Ethernet WAN/management portsp.39Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switchp.40Completing the hardware installationp.40Chapter 3 Configuring the Matrix Switch for operationp.41Introductionp.42Configuration prerequisitesp.42Initial configuration through the RS-232 control portp.43Connecting the DB9-RJ45 adapter with the included cablep.43Setting up the HyperTerminal (or similar program) sessionp.44Using a browser to complete Model 6511RC configurationp.47Displaying the Matrix Switch 6511RC web administration pagesp.47Home page overviewp.49Configuring the default gatewayp.51Configuring the system clocking parametersp.52Module clocking modep.52Module clocking source and fallbackp.53Configuring the SDH circuit parametersp.54Accessing the SDH circuit parametersp.55Configuring the SDH physical interface typep.56Configuring the SDH interface parametersp.56Configuring the SDH path trace parametersp.57Configuring DS0 idle codesp.58Accessing the idle code configurationp.59Defining the DS0 idle code configurationp.60Selecting the SDH mapping pathp.60Defining DS0 mappingsp.62Defining DS0 mappings using E1 port formatp.64Examples for configuring DS0 mappings.p.65Defining DS0 mappings using TU formatp.69Examples for configuring DS0 mappings.p.72Saving your configurationp.74Backing up your configuration parametersp.75Backing up the configuration store in flash memoryp.76Completing the installationp.77Chapter 4 Operation and shutdownp.79Introductionp.80Activating the Model 6511RCp.80De-activating the Model 6511RCp.80Chapter 5 Troubleshooting and maintenancep.81Introductionp.82Troubleshooting during initial deploymentp.82General fault analysisp.83Matrix Switch test toolsp.86Loopback test modes for the STM-1 portp.86Facility Loop [sonetFacilityLoop(1)]p.87Terminal loop [sonetTerminalLoop(2)]p.88Other Loop [sonetOtherLoop(3)]p.90SDH section trace and path tracep.90Sections and pathsp.91Section tracep.91Path tracep.92Number of paths per framep.93Periodic maintenancep.94Calibrationp.94Maintenancep.94Replacing the Model 6511RCp.94Exporting the current Model 6511RC configurationp.94Removing the defective Model 6511RCp.97Installing the replacement Model 6511RCp.98Importing a saved configurationp.98Completing the installationp.99Chapter 6 Contacting Patton for assistancep.101Introductionp.102Contact informationp.102Warranty Service and Returned Merchandise Authorizations (RMAs)p.102Warranty coveragep.102Out-of-warranty servicep.102Returns for creditp.102Return for credit policyp.103RMA numbersp.103Shipping instructionsp.103
Page 102 of the Patton electronic 6511RC user manual — Warranty Service and Returned Merchandise Authorizations (RMAs)
Page 102 · click to enlarge
Page 102

6 • Contacting Patton for assistance Model 6511RC User Manual

Introduction

This chapter contains the following information:

  • “Contact information” —describes how to contact PATTON technical support for assistance.
  • “Warranty Service and Returned Merchandise Authorizations (RMAs)” —contains information about the RAS warranty and obtaining a return merchandise authorization (RMA).

Contact information

Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.

  • Online support—available at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a> .
  • E-mail support—e-mail sent to support@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a> will be answered within 1 business day
  • Telephone support—standard telephone support is available Monday through Friday, from 8:00 A.M. to 5:00 P.M. EST (8:00 to 17:00 UTC-5), Monday through Friday by calling +1 (301) 975-1007

Warranty Service and Returned Merchandise Authorizations (RMAs)

Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.

Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.

Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or elephants may require replacement.

Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.

102 Introduction

Page 103 of the Patton electronic 6511RC user manual — Return for credit policy
Page 103 · click to enlarge
Page 103

Model 6511RC User Manual 6 • Contacting Patton for assistance

Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.

  • 30 to 120 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
  • Over 120 days: Products will be accepted for repairs only.

RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:

  • Completing a request on the RMA Request page in the Support section at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a>
  • By calling +1 (301) 975-1000 and speaking to a Technical Support Engineer
  • By sending an e-mail to returns@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a>

All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.

Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:

Patton Electronics Company RMA#xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA

Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.

Warranty Service and Returned Merchandise Authorizations (RMAs) 103

Page 104 of the Patton electronic 6511RC user manual — Return for credit policy
Page 104 · click to enlarge
Page 104

6 • Contacting Patton for assistance Model 6511RC User Manual

104 Warranty Service and Returned Merchandise Authorizations (RMAs)

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
POWER LED (green) is extinguishedTo verify that power is being supplied to the Model 6511RC via the CPCI chassis power bus: verify that at least one chassis power supply module is installed in the chassis and functioning normally. p.82
POWER LED (green) is flashingThe 6511RC has detected a power failure on a power bus. There may be a prob- lem with the CPCI chassis power system which feeds the Model 6511RC such as a failed power supply module in the chassis. The Model 6511RC will function nor- mally with one power supply. Inspect the power supplies in the CPCI chassis to identify and replace the failed power supply module. If no failed power supply is found, or if the POWER LED continues flashing, contact Patton Technical Support to determine if the Matrix Switch should be replaced. p.82
CPU FAIL LED (red) is litCPU is unable to load the software from FLASH to RAM for operation. As soon as possible, remove the Model 6511RC from the CPCI chassis, wait 30 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disap- pears. If the CPU FAIL LED remains lit after the Model 6511RC completes the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch needs to be replaced. p.82
ALARM LED (yellow) is lit or flashingIndicates The 6511RC has detected a minor or major alarm condition. Examine the Alarm System Overview web management page to determine exactly which alarm(s) is(are) active. p.82
SYSTEM LED (green) is not flashingThe Model 6511RC is not functioning properly. As soon as possible, force a module power cycle as follows: 1)Wearing an antistatic strap, simultaneously press both red buttons on the front- panel handles of the 6511RC to unlock the handles and prepare the module for removal. 2)Simultaneously press both black handles outward and away from the center of the module to unseat the 6511RC from the mid-plane connectors. 3) Wait 10 seconds. 4)Holding the module by the two black handles, very carefully push the module gently and firmly into the chassis until it is reseated against the midplane. 5)Press the black handle so that they click and lock closed. Once the Matrix Switch has resumed operation re-inspect the SYSTEM LED. If the SYSTEM LED does not begin flashing after completing the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch should be replaced. p.83

Ask about the Patton electronic 6511RC

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 6511RC

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 6511RC manual PDF

104 pages·6 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…