User Manual


Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Copyright © 2012, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton
Electronics assumes no liability for errors that may appear in this document.
The software described in this document is furnished under a license and may
be used or copied only in accordance with the terms of such license.


Radio and TV Interference The Model 6511RC generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. The Model 6511RC has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide rea- sonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 6511RC causes interference to radio or tele- vision reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the comput- ing equipment and receiver are on different branches).
Users should not attempt to establish or modify ground connections themselves, instead they should contact the appropriate electric inspection authority or electrician.
FCC Part 68 (ACTA) Statement This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.
This equipment uses a Universal Service Order Code (USOC) jack: RJ-11C.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
Industry Canada Notice

Compliance Information Model 6511RC User Manual
If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you dis- connect the equipment until the problem is resolved.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
In accordance with FCC rules and regulation CFR 47 68.218(b)(6), you must notify the telephone company prior to disconnection. The following information may be required when applying to your local telephone company for leased line facilities. The Universal Service Order Code (USOC) is RJ48. The Facility Interface Codes (FIC) are 04DU9-BN, 04DU9-DN, 04DU9-1KN, and 04DU9-1SN. The Service Order Code (SOC) is 6.0N.
CE Notice The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromag- netic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Certificate of Compliance is available by contacting Technical Support.

This guide describes installing and configuring a Patton Electronics Model 6511 TDM-Digital Access Con- centrator (Matrix Switch). By the time you are finished with this guide, your Matrix Switch will be connected to the remote DSL modems and transferring data. The instructions in this guide are based on the following assumptions:
This guide is intended for the following users:
This guide contains the following chapters and appendices:
For best results, read the contents of this guide before you install the Matrix Switch.

About this guide Model 6511RC User Manual
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and CAUTION heading indicate a potential haz- ard. Strictly follow the instructions to avoid property damage.
This section describes the typographical conventions and terms used in this guide.
General conventions The procedures described in this manual use the following text conventions:
Table 1. General conventions

Model 6511RC User Manual About this guide
Table 1. General conventions (Continued)
Mouse conventions The following conventions are used when describing mouse actions:
Table 2. Mouse conventions

About this guide Model 6511RC User Manual


1 • Introduction Model 6511RC User Manual
The Model 6511RC Matrix Switch (see figure 1) combines TDM aggregation and cross-connection with high- speed packet switching over synchronous digital hierarchy (SDH) and Ethernet uplinks for the Patton Fore- Front Access Infrastructure Solutions (AIS) system. The web-manageable Matrix Switch provides a fully non- blocking mapping and switching matrix for TDM and Ethernet traffic traversing the ForeFront chassis or chas- sis segment. With the Model 6511RC, ForeFront AIS can deliver aggregated TDM and IP traffic on high- speed SDH and Ethernet trunks. The Matrix Switch is designed for installation and operation in either the ForeFront Xtreme Model 6676 cPCI 9U chassis or the ForeFront FullPipe Model 6476 6U chassis. Each model 6511RC Matrix Switch includes an on-board TDM multiplexer, a powerful Ethernet switch, a 155 Mbps SDH/STM-1 trunk port, and two 10/100/1000 Mbps Ethernet interfaces for high-speed packet- switched uplinks.

Figure 1. Model 6511RC Matrix Switch front blade
14 Model 6511RC Matrix Switch overview

Model 6511RC User Manual 1 • Introduction
Figure 2 shows the major functions and connections the Matrix Switch provides within the ForeFront chassis. Each Model 6511RC enables service providers to perform SDH multiplexing and demultiplexing with any-to- any timeslot mapping for up to 2048 DS0 channels. The on-board TDM multiplexer can map any of the 4096 DS0 timeslots on the TDM bus in the chassis midplane to any of the 2048 DS0s on the STM-1 uplink. Each DS0 consists of a 64 kbps communication channel, or timeslot. The integrated SDH aggregator combines DS0 channels into E1 signal streams, then maps those E1s into a STM-1 signal for high-speed transmission on the SDH trunk.

Figure 2. Model 6511RC Matrix Switch major functions and interfaces
The Model 6511RC provides an Ethernet-switching fabric for packet-based management and user traffic tra- versing the ForeFront chassis. The powerful Ethernet switch connects the high-speed packet-switched bus in the ForeFront chassis midplane with two 10/100/1000 Ethernet uplinks. Offering fast Ethernet switching and flexible timeslot aggregation, the Model 6511RC Matrix Switch enables the ForeFront AIS system to deliver a surprisingly compact, high-speed trunking solution at very low cost.
Model 6511RC Matrix Switch overview 15

1 • Introduction Model 6511RC User Manual
The Model 6511RC combines DS0 cross-connection and concentration with powerful Ethernet switching in a single-slot blade for installation in a standard CPCI chassis. The Matrix Switch card-set comprises two mod- ules, a processor blade (see figure 1 on page 14) inserted from the front of the ForeFront chassis, and a rear interface blade (see figure 3) inserted opposite to the processor blade. The front and rear blades mate at the mid-plane, which provides the communication path between front and rear blades (see figure 4).

Figure 3. Model 6511RCT rear blade
Figure 4. Model 6511RC Matrix Switch front and rear blade installation

Model 6511RC User Manual 1 • Introduction

Figure 5. Model 6511RC front panel LEDs and ports
The front panel of the processor blade presents LED status indicators, an RS-232 configuration port and a 10/100 Ethernet management port (see figure 5). The rear entry interface blade (see figure 6 on page 18) pre- sents LEDs indicating alarm and WAN status, physical connectors for the STM-1 port, as well as two 10/100/1000 Ethernet RJ-45 connectors with embedded link and activity status indicator LEDs.
Hardware overview 17

1 • Introduction Model 6511RC User Manual

Figure 6. Model 6511RCT rear entry car front panel LEDs and ports
Three versions of the rear card offer the following connector types for the STM-1 port:
The Model 6511RC connects to other blades in the chassis via the ForeFront cPCI chassis midplane. The chas- sis mid-plane contains two digital communications busses, the H.110 TDM bus, and the PICMG 2.16 Packet-Switched Ethernet bus. The front blade connects to both busses via connectors on the chassis mid- plane. The blade uses the two mid-plane busses for digital communications with other processor blades installed and operating in the chassis.
18 Hardware overview

Model 6511RC User Manual 1 • Introduction
ForeFront chassis architectures The Model 6511RC can be installed in the following ForeFront cPCI chassis:
ForeFront Model 6476 6U cPCI chassis The ForeFront Model 6476 6U cPCI chassis provides 8 slots for installing cPCI processor blades (see figure 7). The Model 6476 chassis accepts up to two Model 6511RC blades, installed in the fabric slots (designated by a yellow blade guide). Using the H.110 TDM and PICMG 2.16 packet busses residing in the chassis mid-plane, an installed Model 6511 can communicate with the other blades installed and operating in the remaining slots.

Figure 7. Model 6476 chassis, front view
Hardware overview 19

1 • Introduction Model 6511RC User Manual

Figure 8. Model 6676 chassis, front view
The ForeFront Model 6676 9U chassis The ForeFront Model 6676 9U chassis offers 17 slots for installing cPCI processor blades (see figure 8). The Model 6676 midplane is divided into segment R (slots 1 through 8) and segment L (slots 9 through 17). Each mid-plane segment contains its own H.110 and PICMG 2.16 bus, so since each 6511RC connects to one mid- plane segment, two Matrix Switch blades, installed in each of the two segments, are required to serve an entire Model 6676 chassis. The Model 6676 chassis can accept up to four Model 6511RC blades installed in slots called fabric slots (slots 1, 2, 9, and 10) designated by yellow card guides. In each backplane segment, a maxi- mum of two 6511RC blades can be installed for operation to provide switching functions for that segment.
20 Hardware overview

Model 6511RC User Manual 1 • Introduction
The Model 6511 communicates with the other blades installed and operating in the same segment over the H.110 TDM and PICMG 2.16 packet busses residing in the chassis mid-plane.
Matrix Switch functionality The Model 6511 provides the following functionality:
TDM mapping and aggregation The Model 6511RC Matrix Switch concentrates the traffic capacity of up to 63 E1 lines for delivery on a 155.54 Mbps optical or electrical STM-1 uplink. For E1 traffic aggregation, the Matrix Switch performs mul- tiplexing and demultiplexing for all 63 E1 lines comprising the 155.52 Mbps STM-1 uplink. Each E1 line comprises 32 DS0 timeslots. Each timeslot comprises a 64 kbps communication channel, or DS0. The Model 6511RC delivers a fully non-blocking switching matrix to the ForeFront system, providing any-to-any map- ping between all 4096 half-duplex DS0 timeslots carried in the H.110 bus and all 4032 half-duplex DS0 timeslots in the SDH STM-1 uplink.
Hardware overview 21

1 • Introduction Model 6511RC User Manual
TDM bus architecture The Matrix Switch provides an interface to the H.110 bus within the ForeFront chassis.The total capacity of the H.110 bus is 4096 half-duplex DS0 channels, the equivalent of 64 E1 lines (see figure 9). Each DS0 chan- nel can be mapped in either direction, transmitting to the Matrix Switch or receiving from the H.110 bus. The H.110 bus organizes the 4096 half-duplex DS0 channels into 32 H.110 ports. Each of the 32 H.110 ports car- ries 128 half-duplex 64 kbps timeslots (DS0s).

Figure 9. H.110 bus and STM-Link capacity
STM-1 link architecture The 155.52 Mbps STM-1 uplink carries 2016 full-duplex (4032 half-duplex) DS0 channels organized into 63 E1 signal streams. Each E1 stream carries 32 full-duplex DS0 channels (64 half-duplex timeslots). The total capacity of the STM-1 uplink on the Model 6511RC is 2016 full-duplex DS0s, the equivalent of 63 E1 lines. The following sequence describes the process by which the Matrix Switch maps and multiplexes 63 E1 streams into the architecture of the STM-1 signal stream:
Multiplexing occurs at the following points in the mapping sequence:
- Three TU-12s are multiplexed into one tributary unit group-2 (TUG-2).
- Seven TUG-2s are multiplexed into one TUG-3 or administrative unit-3 (AU-3).
- Three AU-3s or TUG-3s are multiplexed into one administrative unit group-1 (AUG-1).
22 Hardware overview

Model 6511RC User Manual 1 • Introduction
Figure 10 highlights the multiplexing structure of the STM-1 link by ommitting the intermediate steps in the SDH mapping sequence

Figure 10. E1-to-STM-1 multiplexing structure
Matrix Switch TDM capacity The Matrix Switch provides the means for you to map any DS0 on the H.110 TDM bus to any DS0 on the STM-1 trunk and vice-versa. The difference in capacity between the H.110 bus and the STM-1 link is 64 half- duplex DS0s, the equivalent of one E1 line. The STM-1 uplink provides sufficient capacity to aggregate 98% of the traffic capacity of the H.110 TDM bus. The Model 6511RC provides the capability to map and aggre- gate traffic on the H.110 bus up to the full capacity of the STM-1 trunk.
Matrix Switch Ethernet Switching The Matrix Switch also delivers Ethernet connectivity and switching for any Ethernet traffic traversing the PICMG 2.16 bus to which the blade is connected. The Model 6511RC provides the Ethernet switching fabric for all other blades connected to the same PICMG 2.16 packet-switching bus within the chassis mid-plane. The built-in Ethernet switch switches Ethernet traffic between the PICMG 2.16 bus, the 10/100 Ethernet LAN port presented on the front panel of the front blade, and the two 10/100/1000 Ethernet WAN uplink ports presented on the 6511RCrear panel of the rear blade. All three Ethernet ports provide access to the SNMP agent and HTTP Web Management services within the 6511RC. In addition, all three Ethernet ports provide access via the Internet Protocol to the other blades on the packet bus, including access to the Web Management services residing within those blades. When combined with an external network management system, the Ethernet switching feature on the 6511RC makes it possible to implement a packet-based network management solution for all system elements connected to the same packet-switched bus in the ForeFront chassis.
Hardware overview 23

1 • Introduction Model 6511RC User Manual
Management Services By providing a rich set of industry-standard management services accessible by a full menu of physical inter- faces, the Model 6511RC offers an extensive selection of management options. The Matrix Switch provides the following management services:
Management Interfaces You can reach the Matrix Switch’s management services via any of the following physical interfaces:
Management Approach Managing the Model 6511RC’s may be approached using one of two schemes, generally referred to as In-band or Out-of-band management. In-band management refers to those schemes in which management informa- tion traverses the same network resources as network user traffic. Out-of-band management refers scenarios in which management information does not traverse the same resources as network user traffic. In other words, out-of-band management involves implementing a secondary, special-purpose, management network dedi- cated to carrying management information about the primary, user network. In-band management is more efficient. However, because management information is susceptible to failures in the user network., it is less reliable. Out-of-band management, while more reliable, is also more costly because it involves more equip- ment.
Management access paths into the Model 6511RC for both In-band and Out-of-band approaches are described below.
- The two RJ-45 10/100/1000 Ethernet trunk ports on the rear panel of the rear blade support in-band
management for applications where the Ethernet link is used as an aggregated trunk for user traffic as well as a path for management information. An external management workstation communicates with the management services in the Matrix Switch via a routed-protocol connection within the Ethernet link. The management connection terminates at the management service within the Matrix Switch.
Management · 24 Hardware overview

Model 6511RC User Manual 1 • Introduction
- The PICMG 2.16 packet-switched bus (PSB). In order to manage the Matrix Switch in-band via the
PICMG 2.16 PSB, an external management workstation connects to the ForeFront chassis via another ForeFront blade with management routing capability, such as the Model 6801RC EdgeRoute Network Access Server or model 3096RC TDM Digital Access Concentrator, operating on the same bus. The external management workstation communicates with the ForeFront system using either a Frame Relay or PPP link within a DS0 or within an Ethernet link. The in-band management link terminates on the module with management routing capability, which in turn communicates with the management services in the Matrix Switch over the PICMG 2.16 PSB.
- The RS-232 config port on the front panel of the front blade
- The RJ-45 10/100 Ethernet LAN port on the front panel of the front blade
- The two RJ-45 10/100/1000 Ethernet LAN ports on the rear panel of the rear blade, in applications
where these Ethernet links are dedicated to management traffic.
WAN Interfaces The 6511RC provides connections to the following WAN interfaces:
The STM-1 WAN uplink port may be connected to an SDH network via the Optical SC ore electrical BNC connectors presented on the rear blade.
Mid-Plane Interfaces • Connection to the H.110 Time-Division Multiplexed bus providing 4096 DS0 channels of 64 kbps each -Physical and electrical connections via the mid-plane connector block on the rear of the front blade
LAN Interface The 10/100-Mbps Ethernet LAN port is presented on an RJ-45 connector with an auto-sensing/full-duplex 10Base-T or 100Base-T interface. Also included are:
Matrix Switch Interfaces · Hardware overview 25

1 • Introduction Model 6511RC User Manual
RS-232 Config port The RS-232 Config port provides access to the CLI management service. You will use the Config port to per- form initial configuration of the Model 6511RC. The RS-232 port supports:
Power system The 6511RC obtains power from the CPCI chassis via PCMG 2.11 47-pin power connectors on the front and rear blade. Total power consumption is a maximum of 43 Watts, provided by modular power supplies installed in the cPCI chassis.
Central processing unit The 6511RC employs an Intel i960VH RISC processor operating at 100 MHz/100 Mips. The CPU controls the memory, front/back-panel and management interface for DS0 timeslot mapping, Ethernet switching, loop- back and management services. System memory provided by:
System timing The system timing for the Matrix Switch must be configured using the blade’s management services, typically via Web Management.
Clocking Mode When configured in Master mode, the Matrix Switch serves as the Master clock source (timing reference) for all other blades on the same H.100 bus within the Model 6476 chassis or Model 6676 chassis segment. When configured in Backup mode, the Matrix Switch serves as an alternate Master clocking source (backup) should the Master clocking source fail. When configured in Slave mode, the Matrix Switch will not provide system timing over the H.100 bus for any other blades.
Clocking Source Regardless of its clocking mode, the Matrix Switch can derive its own system timing from several sources. You will define two clocking sources for the Matrix Switch, a first-choice (Primary Reference) and an alternate (Fallback Reference). The Matrix switch will derive its own system timing from the Primary Reference as long as it remains available. Should the Primary Reference become unavailable, the Matrix Switch will switch over to the Fallback reference as the clock source for its own system timing. The following clocking sources can serve as either the Primary Reference or Fallback Reference for the Matrix Switch:
26 Hardware overview

Model 6511RC User Manual 1 • Introduction
Humidity 5 to 95% relative humidity (RH), non-condensing
Physical dimensions • 1.75 inches (4.44 cm) height, standard 19-inch (48.26 cm) width, 12-inch (30.48 cm) depth
LED Indicators LED indicators on the front panel (see figure 5 on page 17) and rear panel (see figure 6 on page 18) display the status of Matrix Switch system resources. The front-panel LEDs are described in table 3. The rear-panel LEDs are described in table 4 on page 28.
Table 3. Front-panel LED indicators
LED Color Status Meaning
POWER Green On solid Power is being applied.
Flashing The 6511RC has detected a power failure on a power bus.
Off No input power is being applied.
CPU FAIL Red On solid CPU is unable to load the software from FLASH to RAM for operation.
Off The CPU is operating normally.
ALARM Yellow On solid A minor alarm condition has been detected.
Flashing A major alarm condition has been detected.
Off The Model 6511RC system is operating normally.
SYSTEM Green Flashing The Model 6511RC system is operating normally.
Off The Model 6511RCsystem is not functioning properly.
ENET(NODE) Green On solid Indicates there is Ethernet frame activity on one or more of the 6511RC’s Ethernet inter-
faces, including the two rear-panel 10/100/1000 ports, the front -panel 10/100 port, and the packet--switched PICMG 2.16 bus.
Off Indicates NO Ethernet frame activity detected on any of the 6511RC’s Ethernet interfaces, including the PICMG 2.16 bus.
CLK SOURCE Green On solid The 6511RC is defined as the Primary (master) clock source for the H.100 bus
Flashing The 6511RC is defined as the Secondary (alternate master) clock source.
Off The 6511RC is defined as a slave, deriving its clock from the H.110 Bus.
CLK ERROR Yellow On solid Primary Master Clock source has been lost and the 6511RC is using the secondary
source for its clock.
Flashing Master Clock source and the Secondary Clock source have been lost and the 6511RC
is using its internal crystal for its clock.
Off No clock errors currently detected.
Hardware overview 27

1 • Introduction Model 6511RC User Manual
Table 3. Front-panel LED indicators (Continued)
LED Color Status Meaning
TEST MODE Green On solid One or more Ethernet ports or the STM-1 port is in test mode.
Flashing One or more Ethernet ports or the STM-1 port is in test mode and errors have been
received.
Off None of the ports is operating in test mode.
WAN Green On solid Indicates the STM-1 port is activated, synched, and operating normally.
Flashing Indicates that the STM-1 port is detecting the SDH network, but is unable to synchro-
nize with it.
Off Indicates rear blade not present or STM-1 port is not configured
ENET(SWITCH) Green On solid Indicates there is Ethernet frame activity on at least one of the eight PICMG 2.16 connec-
tions to other blades on the PSB bus.
Off No Ethernet frame activity detected on the PICMG 2.16 bus.
ENET(REAR) Green On Indicates Ethernet frame activity on one or both of the 10/100/1000 Ethernet ports
Off There is NO Ethernet frame activity on either of the 10/100/1000 Ethernet ports
ON LINE On Reserved for future use
Off Reserved for future use
10/100 ENET Green On Ethernet Link is established
Integrated LEDs Off No Ethernet link is established
on RJ-45 Yellow On Flashes to indicates Ethernet frame activity on this port
Connector Off Indicates no Etherent frame activity on this port
READY Blue On Card ready for removal from cPCI chassis.
Off Card not ready for removal from cPCI chassis.
Table 4. Rear-panel LED indicators

ALARM Red On solid A minor alarm condition has been detected.
WAN Green On solid Indicates the STM-1 port is activated, synched, and operating normally.
Flashing Indicates that the STM-1 port is detecting the SDH network, but is unable to synchro-
Off Indicates rear blade not present or STM-1 port is not configured
on RJ-45 Yellow On Flashes to indicates Ethernet frame activity on this port
Connector Off Indicates no Etherent frame activity on this port
on RJ-45 On Flashes to indicates Ethernet frame activity on this port
Connector Off Indicates no Etherent frame activity on this port
Ready Blue On Card ready for removal from cPCI chassis.
Off Card not ready for removal from cPCI chassis.
28 Hardware overview

Model 6511RC User Manual 1 • Introduction
The Model 6511RC Matrix Switch has achieved the following approvals and certifications:
- Industry Canada CSA C22.2 No. 60950
- EMC Directive 89/336/EEC
- Low Voltage Directive 73/23/EEC (EN 60950)
- ETSI CTR 13
- FCC Part 15, Subpart B, Class A
- FCC Part 68
- Industry Canada CS-03
Approvals 29

1 • Introduction Model 6511RC User Manual
30 Approvals


2 • Hardware installation Model 6511RC User Manual
This chapter contains the following procedures for installing the Model 6511RC Matrix Switch:
Inspect the shipping carton for external damage. Note any damage before removing the container contents. Report equipment damage to the shipping carrier immediately for claim purposes. Save all packing materials in case you need to return an item to the factory for servicing.
The Matrix Switch comes with the following items:
You must verify that the ForeFront chassis is correctly installed before installing the Matrix Switch hardware into the chassis. Check for the following:
- Improper EMI shielding against both incoming and outgoing electromagnetic signals
- Impaired operation of the chassis cooling system, resulting in equipment overheating, including the SHD
laser subsystem on the Matrix Switch
See section “Verifying correct cover plate installation” on page 33 for directions on verifying proper cover plate installation
32 Introduction

Model 6511RC User Manual 2 • Hardware installation
Verfying correct electrical grounding Do the following to verify correct electrical grounding:
Improper chassis grounding may impair the operation of the STM-1 electrical interface, thereby causing data transmission errors on the STM-1 link.

Figure 11. AC power module and DC power module grounding studs locations
– The building ground rod (generally located at the site’s main service entrance)
– A sprinkler system pipe
– A cold-water pipe
– Building structural steel
Verifying correct cover plate installation Missing front or rear panel cover plates leave the chassis interior open and vulnerable to the following problems:
Do the following to verify that cover plates are properly installed:
Verifying that the ForeFront chassis is properly installed 33

2 • Hardware installation Model 6511RC User Manual
Do the following to install the Matrix Switch hardware:

Figure 12. Alignment/ESD pin and card handle
34 Matrix Switch hardware installation

Model 6511RC User Manual 2 • Hardware installation
This section describes installing network interface cables on the following front and rear Matrix Switch blade ports:

Figure 13. Matrix Switch front blade network interface ports

Figure 14. Matrix Switch rear blade network interface ports
Installing the network cables 35

2 • Hardware installation Model 6511RC User Manual
Connecting the front-panel Ethernet LAN port The Matrix Switch includes a 10/100Base-T transceiver, accessible via a physical interface on the front panel of the front blade for connection to an Ethernet LAN. The Ethernet interface complies with IEEE 802.3 and is pre- sented on a 6-pin RJ-45 female receptacle. Once connected to a LAN, the Ethernet port will autosense the speed of the LAN and automatically negotiate half or full-duplex operation. This port provides access to the Matrix Switch’s resident management services, including the HTTP/Web Management feature. This port also connects to the on-board Ethernet Switch, thus providing Ethernet access to other blades within the ForeFront system via the PICMG 2.16 PSB. This section describes connecting the Matrix Switch to the Ethernet LAN via an Ethernet hub, switch, or workstation.
Connecting the 10/100Base-T Ethernet port to an Ethernet switch or hub The 10/100Base-T Ethernet port (see figure 5) is designed to connect to an Ethernet switch or hub. The Ethernet RJ-45 pin and signal definitions for the Matrix Switch or for a NIC card in a workstation/PC are shown in figure 15. Connect a straight-through CAT-5 cable (one wired as shown in figure 15) between the Matrix Switch and the hub/switch.

Figure 15. Ethernet RJ-45 pin and signal definitions for Matrix Switch
Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PC The 10/100Base-T Ethernet port can connect to a single Ethernet-capable workstation or PC by means of a cross-over cable. Refer to figure 16 to assemble a cross-connect cable that will connect between the NIC Ether- net port in the workstation and the Matrix Switch 10/100Base-T Ethernet port.

Figure 16. Cross-over RJ-45-to-RJ-45 Ethernet cable diagram
36 Installing the network cables

Model 6511RC User Manual 2 • Hardware installation
Connecting the front-panel EIA-561 RS-232 configuration port (DCE configured) Install the supplied RJ-45-to-RJ-45 cable with the DB9-RJ45 adapter between the Matrix Switch RS-232 port (see figure 13 on page 35) and an open serial port on your computer. If you need to assemble your own cable, refer to the pinout diagram in figure 17.

Figure 17. RJ-45 pin and signal definitions for Matrix Switch CONFIG port
Connecting the rear-panel STM-1 WAN port to an SDH network The Matrix Switch offers two types of STM-1 interfaces—optical and electrical—presented on the rear panel of the rear blade. Optical interfaces connect to fiber-optic network cables, while the electrical interfaces connect to coaxial network cables. The rear-blade connectors must match the type of network cables and connectors used by the SDH network to which you will connect.
Connecting the STM-1 optical interface to fiber-optic network cables The following versions of the Matrix Switch rear blade offer an optical interface for the STM-1 port
The designation SC20 in the model code denotes that an optical interface conforming to ITU specification G.957 and G.652 is present. The Matrix Switch presents the STM-1 optical interface on a pair of SC fiber- optic connectors, one for the transmiting (TX) and one for receiving (RX) signals (see figure 14 on page 35).
Installing the network cables 37

2 • Hardware installation Model 6511RC User Manual

Figure 18. Fiber-optic SC cable connectors
Do the following to connect the dual singlemode fiber-optic cable (see figure 18) to the STM-1 SC connectors: 1. Remove the protective cap from the fiber optic cable connectors.
Connecting the STM-1 electrical interface to coaxial network cables The Matrix Switch presents the STM-1 electrical interface on a pair of 75-ohm female BNC connectors, one for the transmiting (TX) and one for receiving (RX) signals (see figure 14 on page 35).
For most installations, the coaxial cable connecting the STM-1 WAN port to the SDH network can be no longer than 325 feet (100 meters).
38 Installing the network cables

Model 6511RC User Manual 2 • Hardware installation
Figure 19. BNC coaxial cable connectors
Do the following to connect the dual 75-ohm coaxial cable (see figure 19) to the STM-1 BNC connectors:
Connecting the rear-panel Ethernet WAN/management ports The Matrix Switch provides two 10/100/1000Base-T Ethernet transceivers, accessible via physical interfaces on the rear-panel of the rear blade, for connection to an external router, hub, or switch. Both interfaces are pre- sented on RJ-45 6-pin female receptacles. The interfaces comply with IEEE specification 802.3 and are labeled ENET 1 and ENET 2 (see figure 14 on page 35).
Once connected to a LAN, the Ethernet port will autosense the speed of the LAN and automatically negotiate half or full-duplex operation. The ports provide access to the Matrix Switch’s resident management services, including the HTTP/web management feature. This port also connects to the on-board Ethernet switch, thus providing Ethernet access to other blades within the ForeFront system via the PICMG 2.16 PSB.
You can use the two high-speed Ethernet ports to implement the following functions:
Installing the network cables 39

2 • Hardware installation Model 6511RC User Manual
Connecting the 10/100/1000 Base-T Ethernet ports to a router, hub or switch The 10/100/100Base-T Ethernet ports may be connected to a WAN router, or to an Ethernet hub or switch. To connect the router, hub or switch to the Matrix Switch, you must use a straight-through CAT-5 RJ-45 cable (one wired as shown in figure 15 on page 36). Figure 15 shows the Ethernet RJ-45 pin and signal defi- nitions for the Matrix Switch. For cable distance limitations please consult the IEEE specification 802.3.
To connect the 10/100/100 Base-T Ethernet port to a router, hub or switch:
This section verifies that the Matrix Switch hardware is operational to the point where you can begin configur- ing the software settings.
Power is delivered from the CPCI chassis backplane through the 47-pin PICMG 2.11 power connectors on the 6511RC blades. Upon insertion into the CPCI chassis, the Model 6511RC immediately powers up and begins its boot cycle. During the boot cycle the following should occur:
Hardware installation is now complete. To configure the 6511RC for operation, refer to chapter 3, “Configur- ing the Matrix Switch for operation” on page 41.
40 Completing the hardware installation


3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
This chapter contains the following procedures that describe configuring the Model 6511RC Matrix Switch for operation:
- Displaying the Matrix Switch home page (see “Displaying the Matrix Switch 6511RC web administra-
tion pages” on page 47)
- Defining the IP default gateway (see “Configuring the default gateway” on page 51)
- Defining the system clocking parameters (see “Configuring the system clocking parameters” on page 52
- Defining the STM-1 Circuit parameters (see “Configuring the SDH circuit parameters” on page 54)
- Enabling idle code generation for designated DS0 channels (see “Configuring DS0 idle codes” on
- Defining DS0 mappings within the STM-1 link (see “Selecting the SDH mapping path” on page 60)
You will need the following to configure the 6511RC Matrix Switch:
- RS-232/V.24 serial port
- VT-100 terminal program, e.g., HyperTerminal
- Web browser (e.g., Netscape Communicator or Microsoft Internet Explorer)
- The IP address and subnet mask for the 6511RC’s Ethernet port
- The IP address of the default gateway
page 58) · - Ethernet port · 42 Introduction

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
- Which E1 mapping path will be used within the STM-1 link, either AU3 or AU4.
- Section Trace Message Length
- The value of the JO byte for Section Trace Messages
- Path-1 Trace Message Length
- The value of the J1 byte for Path-1 Trace Messages
- The value of Path-1 Signal Label
- The E1 payload type, either asynchronous or byte synchronous
- a detailed plan describing the desired source and destination for each of the 4096 simplex DS0 channels
within the H.110 bus on the chassis mid-plane
- which DS0 channels within each E1 signal stream should carry an idle code
Initially you must configure the 6511RC’s IP address via the RS-232 Config port located on the Matrix Switch front frame. In rare instances, you may also need to change the netmask from the factory default value.
Connecting the DB9-RJ45 adapter with the included cable Do the following:
Figure 20. Model 6511RC interface ports
Initial configuration through the RS-232 control port 43

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Setting up the HyperTerminal (or similar program) session Do the following:

Figure 21. Connection Description window

Figure 22. Connect To window
44 Initial configuration through the RS-232 control port

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation

Figure 23. COM1 Properties window

Figure 24. Terminal keys configuration
Initial configuration through the RS-232 control port 45

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Figure 25. Login window

Figure 26. VT-100 Top Level Management window
46 Initial configuration through the RS-232 control port

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
This completes the initial configuration of the Model 6511RC. The next steps in configuration will be done using your web browser connected via Ethernet to the 6511RC.
This section describes the following procedures:
Displaying the Matrix Switch 6511RC web administration pages Do the following:
Using a browser to complete Model 6511RC configuration 47

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Figure 27. 6511RC Configuration Menu home page
48 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Home page overview The HOME window is divided into two panes: the Configuration Menu pane and the Configuration/Informa- tion pane (see figure 28). The Configuration Menu contains the links to the various Model 6511RC sub- systems, while in the Configuration/Information pane, you can view status and other information or make changes to the system configuration. Unlike the Configuration Menu pane, which appears the same no matter which subsystem page you may select, the Configuration/Information pane contents will change as you move from one subsystem page to another.

Figure 28. HOME page window panes
Using a browser to complete Model 6511RC configuration 49

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Figure 29. Operator Actions buttons
From the Home page, the following actions can be performed:
50 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Configuring the default gateway The default gateway IP address, if defined, is used solely for managing the 6511RC remotely via the Ethernet port. The 6511RC does not transmit or receive user data nor any other traffic via the default gateway IP address or the Ethernet port.
Do the following to add the default gateway:

Figure 30. IP Overview page

Figure 31. IP Routing Overview page
Using a browser to complete Model 6511RC configuration 51

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Figure 32. Defined Routes table

Figure 33. Define a New Route table
Configuring the system clocking parameters In this section you will define the system clocking configuration for the Matrix Switch. Three issues pertain to system clocking:
Module clocking mode Module clocking mode defines what role the Matrix Switch will assume on the H.110 bus with respect to sys- tem timing. You can select master(1), secondary(2), or slave(3) for the value of Clocking Mode. The master will drive the main reference clock for the chassis. Should the master fail, the secondary will drive the main refer-
52 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
ence. Slaves will not drive any clock reference. Most often the 6511RC will be defined as the master(1), while most other modules in the chassis will be defined as slave(3).
Module clocking source and fallback There are two module clocking source parameters, the primary reference and the fallback reference. Unless it fails or becomes disconnected, the primary reference provides the system clock for the 6511RC. Should this failure occur, the fallback reference will become the clocking source for the 6511RC’s system clock.You must choose one of the following values as the clocking source for each reference:
The following examples illustrate how to define the system clocking parameters for two scenarios.
Example 1. In this example, your 6511RC will be the clocking master for all other modules on the same H.110 bus. Your 6511RC will derive its own timing from its STM-1 port as the main reference, and from its internal oscillator as the fallback reference. To define the system clocking parameters:

Figure 34. System Clocking Overview page, example 1
Using a browser to complete Model 6511RC configuration 53

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Example 2. For this example, another Matrix Switch is the chassis is the clocking master, providing the system clock for the chassis, and your 6511RC is a slave. Your 6511RC will derive its timing from the H.110 bus sys- tem clock as the main reference, and from its STM-1 port as the fallback reference. To define the system clock- ing parameters:

Figure 35. System Clocking Configuration page, example 2
Configuring the SDH circuit parameters In order for the STM-1 link to function correctly, you must correctly define the values of certain configurable parameters that affect the SDH circuit. In order to configure the STM-1 link, you must first gather the follow- ing information:
54 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Accessing the SDH circuit parameters To access the SDH circuit parameters:

Figure 36. SDH Overview web management page

Figure 37. SDH Modify page
Using a browser to complete Model 6511RC configuration 55

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Configuring the SDH physical interface type Do the following to define the physical interface type providing the STM-1 link:

Figure 38. SDH Physical Configuration section
Configuring the SDH interface parameters 1. In the SDH Interface Configuration section (see figure 39), for Circuit Identifier, enter an optional alphanu- meric name for this STM-1 link.

Figure 39. SDH Interface Configuration section
56 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
ter applies. When the section trace message length is defined to be one byte, the Matrix Switch will ignore the value of Section Trace.
Configuring the SDH path trace parameters If you selected AU-4 mapping in the preceding procedure, the Matrix Switch will display one set of five parame- ters pertaining to Path 1. If you selected AU-3 mapping, the Matrix Switch will display three sets of five parame- ters each pertaining to Paths 1, 2, and 3. Do the following to define the values for the SDH path trace parameters:

Figure 40. SDH Path Trace parameters
Using a browser to complete Model 6511RC configuration 57

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Configuring DS0 idle codes If you want your Matrix Switch to encode vacant DS0 channels with the standard E1 idle code (the hexadeci- mal value 7E), you must follow the procedures below to designate which DS0 channels within the STM-1 sig- nal stream should be so encoded. Obviously, in order to correctly define the idle code configuration, you must know which DS0 channels in the SDH frame are expected to be idle. Defining the idle code configuration involves two steps: you must first access the DS0 Idle Code Configuration web management page, then use that page to select the idle DS0 channels from the STM-1 structure and designate them as idle.
58 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Accessing the idle code configuration Do the following to access the Matrix Switch’s idle code configuration:

Figure 41. E1 Link page
– tug3ALL(0) is selected next to the label TUG3
– tug2ALL(0) is selected next to the label TUG2
then click the Submit Query button to display the next page showing E1 link status (see figure 42).

Figure 42. Page showing E1 link status
This page displays all 63 E1 links according to their position within the STM-1 mapping structure: each E1 resides within a tributary unit (TU), 3 TUs reside within each level-2 tributary unit group (TUG-2). The final level of multiplexing concentrates 7 TUG-2s within either a level-3 administrative unit group (AUG-3), or a level-3 tributary unit group (TUG-3). The TUG-3 then resides within a level-4 administra- tive unit group (AUG-4).
Using a browser to complete Model 6511RC configuration 59

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Figure 43. SDH DS0 Idle Code Detail page
Defining the DS0 idle code configuration The SDH DS0 Idle Code Detail page (see figure 43) displays a table for a selected E1, specified by the page title, within the STM-1 link. The table displays the value of the idle code parameter for each of the 32 DS0s within the specified E1 stream. To define the idle code configuration for the selected E1:
To complete the DS0 idle code configuration for the entire STM-1 link, you will ned to repeat the above pro- cedures for each E1 that you want to enable DS0 idle code generation for.
Selecting the SDH mapping path The Matrix Switch offers two options for the SDH mapping path: you can select the mapping path terminat- ing with TUG-2 and AU-3 or TUG-3 and AU-4.
60 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
The mapping path you select will determine which parameter fields the 6511RC will display on the DS0 Map- ping Overview page. You have already selected an SDH mapping type, but you may wish to double-check this value before mapping any DS0s, by doing the following:

Figure 44. SDH Overview page
Figure 45. SDH Modify page
Using a browser to complete Model 6511RC configuration 61

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
You are now ready to define DS0 mappings.
Defining DS0 mappings In order for the STM-1 link to carry traffic through the Matrix Switch to and from the ForeFront system, you must define a set of DS0 mappings (correlations). You will define mappings between the full-duplex DS0s within the STM-1 link and the simplex DS0s within the H.110 bus. While it is not necessary to define a map- ping for every DS0 in the SDH link, only the mapped DS0s will carry user data. Unmapped DS0s may be con- figured to carry an idle code. Otherwise, unmapped DS0s will carry a random bit stream.
For each DS0 Mapping you define, you will create a correlation between a communications channel in the STM-1 link and a communications channel within the ForeFront chassis mid-plane. Each STM-1 channel consists of a set of full-duplex DS0s. Each midplane channel consists of two simplex sub-channels, transmitted and received. Each sub-channel consists of a set of simplex DS0s. You will define each STM-1 channel and each mid-plane sub-channel by specifying one or more timeslot numbers up to a maximum of 32 timeslots per channel. For a STM-1channel you will select up to 32 timeslot numbers from the range numbered 1 to 32. For a mid-plane channel you will select up to 32 timeslots from the range numbered 1 to 128.
On the STM-1 side, there are 63 E1 signal streams, each comprising 32 DS0s. Within an E1, each DS0 is a full-duplex channel, comprising a transmitted and a received signal stream. The STM-1 link comprises 2016 full-duplex DS0s.
On the mid-plane side, there are 4096 simplex DS0s within the H.110 bus, organized into 32 ports. Each H.110 port comprises 128 DS0s. Within the H.110 bus, each DS0 is a simplex signal stream, which the H.110 bus can either transmit or receive. You will define the direction of a mid-plane DS0 during the mapping process as either transmitting to the H.110 bus or receiving from the H.110 bus. The H.110 bus provides 4096 simplex DS0s.
When entering E1 and H.110 timeslot numbers, you must define the same number of timeslots on the SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that represents the timeslot numbers.
The following notation should be used for assigning timeslots:
62 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
The Matrix Switch offers two formats for defining DS0 mappings:
Figure 46 shows the position of each E1 port number within the STM-1 frame.

Figure 46. E1 Port numbers located within the STM-1 frame structure
The following sections describe how to define DS0 mappings.
Using a browser to complete Model 6511RC configuration 63

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual

Figure 47. DS0 Mapping Overview page
Defining DS0 mappings using E1 port format For those with little to moderate experience in working with SDH network architecture, E1 format will most likely the simplest and most straightforward method for defining DS0 mappings. To define a DS0 mapping by E1 number, do the following:
When entering E1 and H.110 timeslot numbers you must define the same number of timeslots on the SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that repre- sents the timeslot numbers.
64 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
The following notation should be used for assigning timeslots:
At this point you have defined the SDH channel composed of a selected E1 signal stream and a set of timeslots within that E1. Now you must define the mid-plane channel to be correlated with the SDH channel.
Examples for configuring DS0 mappings.
Three examples are provided:
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 1-32
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 33-64
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 65-96
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 97-128
- map all 32 timeslots of the E1 received signal to H.110 port 4 timeslots 1-32
- map all 32 timeslots of the E1 transmitted signal from H.110 port 4 timeslots 33-64
Using a browser to complete Model 6511RC configuration 65

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Map E1 Port 1 received, timeslots 1-32 to H.110 Port 1 timeslots 1-32.
Map E1 Port 1 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 33-64.
Solution:

Figure 48. Define a mapping table for Example 1

Figure 49. Defined Mappings table for example 1
You have completed the DS0 mapping procedure for example 1.
66 Using a browser to complete Model 6511RC configuration
Example 1

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Map E1 Port 2 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.
Map E1 Port 2 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 97-128.
Solution:

Figure 50. Define a Mapping table for example 2

Figure 51. Defined Mappings table for example 2
You have completed the configuration for example 2.
Using a browser to complete Model 6511RC configuration 67
Example 2

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Map E1 Port 7 received, timeslots 1-32 to H.110 Port 4 timeslots 1-32.
Map E1 Port 7 transmitted, timeslots 1-32 from H.110 Port 4 timeslots 33-64.
Solution:

Figure 52. Define a Mapping table for example 3

Figure 53. Defined Mappings table for example 3
You have completed the configuration for example 3.
68 Using a browser to complete Model 6511RC configuration
Example 3

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Defining DS0 mappings using TU format Experienced SDH engineers with a solid understanding of STM-1 architecture will most likely prefer to use TU format to define DS0 mappings. To define a DS0 mapping using TU format, do the following:

Figure 54. DS0 Mapping Overview page with TU format selected
Using a browser to complete Model 6511RC configuration 69

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Figure 55. E1 port numbers located within the STM-1 frame structure
5. The first three parameters in the Define a Mapping section (see figure 54 on page 69) specify an E1 signal stream within the STM-1 link. The STM-1 link contains either three TUG-3s or three AU-3s (see figure 55). In the Define a Mapping section, the first parameter name will vary depending on the mapping path you selected on the SDH configuration page. If you selected au3Mapper(0) then Au-3 will be dis- played. If you selected au4Mapper(1) then Tug-3 will be displayed. To define the value of the first map- ping parameter, select from the drop-down menu the AU-3 or TUG-3 number that contains the E1 you wish to map. The options for the value of AU-3 are:
The options for the value of TUG-3 are:
70 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
When entering E1 and H.110 timeslot numbers you must define the same number of timeslots on the SDH and mid-plane sides of the mapping. The timeslots are defined by entering a text string that repre- sents the timeslot numbers.
The following notation should be used for assigning timeslots:
At this point you have defined the SDH channel composed of a selected E1 signal stream and a set of timeslots within that E1. Now you must define the mid-plane channel to be correlated with the SDH channel.
Using a browser to complete Model 6511RC configuration 71

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Examples for configuring DS0 mappings.
Three examples are provided:
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 1-32
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 33-64
- map all 32 timeslots of the received E1 signal to H.110 port 1 timeslots 65-96
- map all 32 timeslots of the transmitted E1 signal from H.110 port 1 timeslots 97-128
- map all 32 timeslots of the E1 received signal to H.110 port 4 timeslots 1-32
- map all 32 timeslots of the E1 transmitted signal from H.110 port 4 timeslots 33-64
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 received, timeslots 1-32 to H.110 Port 1 timeslots 1-32.
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 33-64.
Solution:
You have completed the DS0 mapping procedure for example 1.
72 Using a browser to complete Model 6511RC configuration
Example 1

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
Map TUG-3 or AU-3 no. 2, TUG-2 no. 1, TU-12 no. 1 received, timeslots 1-32 to H.110 Port 1 timeslots 65-96.
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 1 transmitted, timeslots 1-32 from H.110 Port 1 timeslots 97-128.
Solution:
You have completed the configuration for example 2.
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 received, timeslots 1 - 32 to H.110 Port 4 timeslots 1- 32.
Map TUG-3 or AU-3 no. 1, TUG-2 no. 1, TU-12 no. 3 transmitted, timeslots 1 - 32 from H.110 Port 4 timeslots 33- 64.
Solution:
Using a browser to complete Model 6511RC configuration 73
Example 2 · Example 3

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
You have completed the configuration for example 3.
Saving your configuration At this point you have completed the basic configuration of your Matrix Switch for operation. To save your configuration settings in non-volatile RAM, do the following:
Figure 56. 6511RC Home page
74 Using a browser to complete Model 6511RC configuration

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
The 6511RC Matrix Switch provides Import/Export functions that enable you to back up (export) and restore (import) your Matrix Switch’s configuration parameters against possible failure. Should your Matrix Switch ever need replacing, a previously saved copy of your (exported) configuration file can quickly be loaded (imported) into a replacement Matrix Switch.
To import or export a configuration, do the following:

Figure 57. Import/Export page
Backing up your configuration parameters 75

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Backing up the configuration store in flash memory To make a back-up copy of the configuration file currently stored in your Matrix Switch’s flash memory:

Figure 58. Example Matrix Switch flash memory configuration file displayed in a browser
76 Backing up your configuration parameters

Model 6511RC User Manual 3 • Configuring the Matrix Switch for operation
– Click the File menu.
– Click Save As. A dialog box will appear. Use the dialog to save the data displayed on your browser (your
Matrix Switch configuration parameters) to a text file.
– Select the folder in which you want to store the file.
– Type a file name.
– Click Save.

Figure 59. Saving the access server flash memory configuration data as a text file
This section verifies that the Model 6511RC is fully operational.
– On the configuration menu, click the HOME hyperlink to display the Matrix Switch Home Page.
– Scroll down to Operator Actions buttons.
– Click the Hard Reset button.
Completing the installation 77

3 • Configuring the Matrix Switch for operation Model 6511RC User Manual
Note If the Matrix Switch does not behave as described, the most likely cause is that the Matrix Switch SDH parameters values for the STM- 1 link do not match those of the connected SDH network. To resolve this problem, double check the parameters on the Matrix Switch SDH Configuration page against those of the Connected SDH net- work, and correct any incorrect values.
Congratulations! Your Matrix Switch is now installed. If you require further information about configuring your Matrix Switch settings, refer to the Model 6511RC Matrix Switch Administrator’s Reference Guide available online at www.patton.com/manuals/6511RC-arg.pdf.
78 Completing the installation


4 • Operation and shutdown Model 6511RC User Manual
This chapter describes how to start up and power down the Model 6511RC.
The Model 6511RC is activated by completing the procedures in chapter 2, “Hardware installation” on page 31 and chapter 3, “Configuring the Matrix Switch for operation” on page 41. To activate the 6511RC, refer to the procedures in those chapters.
The Model 6511RC is designed for unattended operation. Once the Model 6511RC has been installed and configured, no further operator action is required under normal conditions.
Perform the following procedure to deactivate the Model 6511RC.
80 Introduction


5 • Troubleshooting and maintenance Model 6511RC User Manual
This chapter provides guidance to assist you when performing troubleshooting and fault analysis as a Matrix Switch operator. Should you require more information or technical assistance, refer to chapter 6, “Contacting Patton for assistance” on page 101.
The following table (see table 5) describes the symptoms for system faults that commonly occur when the Matrix Switch is first deployed, along with suggested remedies for each fault.
Table 5. Symptoms
POWER LED (green) is extinguished
To verify that power is being supplied to the Model 6511RC via the CPCI chassis power bus: verify that at least one chassis power supply module is installed in the chassis and functioning normally.
POWER LED (green) is flashing
The 6511RC has detected a power failure on a power bus. There may be a prob- lem with the CPCI chassis power system which feeds the Model 6511RC such as a failed power supply module in the chassis. The Model 6511RC will function nor- mally with one power supply. Inspect the power supplies in the CPCI chassis to identify and replace the failed power supply module. If no failed power supply is found, or if the POWER LED continues flashing, contact Patton Technical Support to determine if the Matrix Switch should be replaced.
CPU FAIL LED (red) is lit CPU is unable to load the software from FLASH to RAM for operation. As soon as
possible, remove the Model 6511RC from the CPCI chassis, wait 30 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disap- pears. If the CPU FAIL LED remains lit after the Model 6511RC completes the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch needs to be replaced.
ALARM LED (yellow) is lit or flashing
Indicates The 6511RC has detected a minor or major alarm condition. Examine the Alarm System Overview web management page to determine exactly which alarm(s) is(are) active.
Problem Corrective Action · 82 Introduction

Model 6511RC User Manual 5 • Troubleshooting and maintenance
Table 5. Symptoms (Continued)
SYSTEM LED (green) is not flashing
The Model 6511RC is not functioning properly.
As soon as possible, force a module power cycle as follows:
1)Wearing an antistatic strap, simultaneously press both red buttons on the front- panel handles of the 6511RC to unlock the handles and prepare the module for removal.
2)Simultaneously press both black handles outward and away from the center of the module to unseat the 6511RC from the mid-plane connectors.
4)Holding the module by the two black handles, very carefully push the module gently and firmly into the chassis until it is reseated against the midplane.
5)Press the black handle so that they click and lock closed.
Once the Matrix Switch has resumed operation re-inspect the SYSTEM LED. If the SYSTEM LED does not begin flashing after completing the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch should be replaced.
The following procedures outline steps you should follow when troubleshooting a Model 6511RC malfunction.
Table 6. LED status indications and recommended actions
LED Location Color Status Meaning
Green On solid Power is being applied. No action recommended.
Flashing The 6511RC has detected a power failure on a power bus. There may
be a problem with the CPCI power supply system such as a failed power supply module in the chassis. The Model 6511RC will function normally with one power supply.
Inspect the power supplies in the CPCI chassis to identify and replace the failed power supply module. If the POWER LED continues flashing when all chassis power supplies are functional, contact Patton Technical Sup- port to determine if the Matrix Switch should be replaced.
Off No input power is being applied. Verify that at least one chassis power supply module is installed in the chassis and functioning normally.
General fault analysis 83
Problem Corrective Action · POWER Front panel

5 • Troubleshooting and maintenance Model 6511RC User Manual
Table 6. LED status indications and recommended actions (Continued)
LED Location Color Status Meaning
CPU FAIL Front panel
Red On solid CPU is unable to load the software from FLASH to RAM for operation.
As soon as possible, remove the Model 6511RC from the CPCI chassis, wait 30 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disappears.
If the CPU FAIL LED remains lit after the Model 6511RC completes the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch needs to be replaced.
Off The CPU is operating normally. No action recommended.
Red On solid A minor alarm condition has been detected.
Flashing A major alarm condition has been detected.
Off The Model 6511RC is operating normally. No action recommended.
Green Flashing The Model 6511RC is operating normally. No action recommended.
The Model 6511RC is not functioning properly.
As soon as possible, remove the Model 6511RC from the CPCI chassis, wait 10 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disappears.
Once the Matrix Switch has resumed operation re-inspect the SYSTEM LED. If the SYSTEM LED does not begin flashing after completing the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch should be replaced.
Green Flash- ing or On solid
Indicates there is Ethernet frame activity on one or more of the 6511RC’s Ethernet interfaces, including the two rear-panel 10/100/1000 ports, the front -panel 10/100 port, and the packet--switched PICMG 2.16 bus. No action recommended
Off • Indicates NO Ethernet frame activity detected on any of the 6511RC’s Ethernet interfaces, including the PICMG 2.16 bus.
Green On solid The 6511RC is set as the Master Clock source.
No action recommended.
Flashing The 6511RC is set as the secondary clock source.
No action recommended.
Off The 6511RC is set as the slave, getting its clock from the H.110 Bus. No action recommended.
84 General fault analysis

Model 6511RC User Manual 5 • Troubleshooting and maintenance
Table 6. LED status indications and recommended actions (Continued)
LED Location Color Status Meaning
CLK ERROR Front panel
Yellow On solid • Primary Reference clocking source has been lost and the 6511RC is using the Secondary Reference as its clocking source. Matrix Switch operation should continue unimpaired.
Flashing • Master Clock source and the Secondary Clock source have been lost and the 6511RC is using its internal crystal for its clock. Matrix Switch operation should continue unimpaired.
Off No clock errors currently detected. No action recommended.
TEST MODE Front panel
Green On solid The STM-1 port is currently operating in some test mode.
No action recommended.
Off None of the G.SHDSL ports is operating in test mode. No action recommended.
WANa Front Panel
Green On solid Indicates the STM-1 port is activated, synched, and operating normally.
No action recommended.
Indicates that the Model 6511RC is detecting the SDH network, but is unable to synchronize with it.
Off • Indicates rear module not present or STM-1 port is not configured.
Indicates there is Ethernet frame activity on at least one of the eight PICMG 2.16 connections to other blades on the PSB bus.No action recommended.
Off Indicates no Ethernet frame activity detected on the PICMG 2.16 bus. No action recommended.
Indicates Ethernet frame activity on one or both of the 10/100/1000 Ethernet ports. No action recommended
General fault analysis 85

5 • Troubleshooting and maintenance Model 6511RC User Manual
Table 6. LED status indications and recommended actions (Continued)
LED Location Color Status Meaning
Off There is NO Ethernet frame activity on either of the 10/100/1000 Ethernet ports. No action recommended
Blue On Indicates module is ready for removal from cPCI chassis.
Off Indicates module NOT ready for removal from cPCI chassis. Do not remove card from chassis.
Yellow On solid A minor alarm condition has been detected.
Flashing A major alarm condition has been detected.
Off The Model 6511RC is operating normally. No action recommended.
Blue On Card ready for removal from cPCI chassis.
Off Card not ready for removal from cPCI chassis. Do not remove card from chassis.
ON LINE On Reserved for future use
Off Reserved for future use
Green On Ethernet Link is established
Integrated LEDs on RJ- 45 connec- tor
Off No Ethernet link is established
Yellow On Flashes to indicates Ethernet frame activity on this port
Off Indicates no Ethernet frame activity on this port
READY Blue On Card ready for removal from cPCI chassis.
Off Card not ready for removal from cPCI chassis.
a. This LED provides status indications for the STM-1 WAN link established via the optical or electrical ports on
the Rear Module of the 6511RC
For the purpose of testing and troubleshooting the STM-1 link, the DS0 Mapping definitions, and H.110 bus connectivity, the Model 6511RC Matrix Switch offers the following tool sets:
The following sections describe these tool sets in detail.
Loopback test modes for the STM-1 port The Matrix Switch provides the following diagnostic loopback test modes for the STM-1 port:
The facility and terminal loops are specified by the SDH protocol. The H.110 loop is proprietary to the Fore- Front Matrix Switch, and fulfills the SDH specification for a third vendor-defined loop.
86 Matrix Switch test tools
![Page 87 of the Patton electronic 6511RC user manual — Facility Loop [sonetFacilityLoop(1)]](/cdn/reader/5a/5aca7ce5b67b7f1d90476f112e0d2182427ae03b1225a3e3a8afb15c189f5ad6/images/page-87.webp?w=400)
Model 6511RC User Manual 5 • Troubleshooting and maintenance
To understand how these test modes work, you must first understand the basic architecture of the Model 6511RC’s TDM mapping functions. The TDM mapping function provides the connection between the STM-1 port and the H.110 bus. Within the TDM mapper (see figure 60) data passes between the SDH fram- ing processor and the H.110 framing processor.
H.110 bus STM-1 port
H.110 Framer
Model 6511RC Matrix Switch
Figure 60. Matrix Switch TDM mapping architecture
The various loopback test modes route data through one or both of these framing processors, with the data path making a U-turn in one framer or the other. Subsequent paragraphs describe the details of each loopback test mode for the STM-1 port.
Facility Loop [sonetFacilityLoop(1)] You can use the facility loop to test and troubleshoot the operation of the STM-1 link, including the Matrix Switch’s STM-1 port and the fiber-optic or coaxial cables connected to it.
The facility loop (see figure 61) returns data received from the SDH facility (the STM-1 link) back to the same SDH facility. In other words, when the Facility Loop is activated, the Matrix Switch receives data from the STM-1 link and transmits the (unmodified) data back to the STM-1 link.
The U-turn for the facility loop occurs within the SDH framer on the Matrix Switch. The data path for the facility loop traverses the SDH framer, but not the H.110 framer. Data enters the Matrix Switch at the STM-1 receive port, and enters the SDH framer where it loops back toward the STM-1 link, leaving the Matrix switch at the STM-1 transmit port.
Figure 61. Facility Loopback test mode
To activate the facility loopback test mode:
Matrix Switch test tools 87
![Page 88 of the Patton electronic 6511RC user manual — Terminal loop [sonetTerminalLoop(2)]](/cdn/reader/5a/5aca7ce5b67b7f1d90476f112e0d2182427ae03b1225a3e3a8afb15c189f5ad6/images/page-88.webp?w=400)
5 • Troubleshooting and maintenance Model 6511RC User Manual
![Patton electronic 6511RC — Terminal loop [sonetTerminalLoop(2)] diagram (page 88)](/cdn/reader/5a/5aca7ce5b67b7f1d90476f112e0d2182427ae03b1225a3e3a8afb15c189f5ad6/images/rimg-43.webp)
Figure 62. SDH Configuration page with sonetFacilityLoop(1) selected
To deactivate the Facility Loopback test mode, from the LoopBack parameter drop-down menu, select sonet- NoLoop(0) and click the Submit button.
Terminal loop [sonetTerminalLoop(2)] The terminal loop (see figure 63) returns data received from the SDH terminals back to those SDH terminals (other ForeFront modules on the same H.110 bus). In other words, when the Terminal Loop is activated, the Matrix Switch receives data from other ForeFront modules via the H.110 bus and transmits the (unmodified) data back to those same modules (via the H.110 bus).
The U-turn for the terminal loop occurs within the SDH framer on the Matrix Switch. The data path for the terminal loop traverses both the H.110 framer and the SDH framer. Data transmitted by the SDH terminals (other ForeFront modules) enters the Matrix Switch from the H.110 bus through the mid-plane
Figure 63. Terminal loopback test mode
88 Matrix Switch test tools
![Page 89 of the Patton electronic 6511RC user manual — Terminal loop [sonetTerminalLoop(2)]](/cdn/reader/5a/5aca7ce5b67b7f1d90476f112e0d2182427ae03b1225a3e3a8afb15c189f5ad6/images/page-89.webp?w=400)
Model 6511RC User Manual 5 • Troubleshooting and maintenance
connections. The data passes through the H.110 framer, then traverses the SDH framer where it loops back, passing through the H.110 framer again. The data leaves the Matrix switch through its mid-plane connections and returns via the H.110 bus to the sending SDH terminals (other ForeFront modules).
The terminal loop affects only those DS0s that are mapped from the H.110 bus to the STM-1 link or from the STM-1 link to the H.110 bus. Likewise, the loop affects only those ForeFront modules included in one or more such DS0 mappings.
The terminal loop exercises the physical and logical connections between the Matrix Switch and the other ForeFront modules connected to the same H.110 bus (its SDH terminals). You can use the terminal loop to test and troubleshoot the DS0 mappings you have defined while simultaneously testing H.110 bus connectiv- ity with other ForeFront modules via the chassis mid-plane.
To activate the Terminal Loop test mode:
![Patton electronic 6511RC — Terminal loop [sonetTerminalLoop(2)] diagram (page 89)](/cdn/reader/5a/5aca7ce5b67b7f1d90476f112e0d2182427ae03b1225a3e3a8afb15c189f5ad6/images/rimg-44.webp)
Figure 64. SDH Configuration page with sonetTerminalLoop(2) selected
To deactivate the terminal loop test mode, from the LoopBack parameter drop-down menu, select sonet- NoLoop(0) and click the Submit button.
Matrix Switch test tools 89
![Page 90 of the Patton electronic 6511RC user manual — Other Loop [sonetOtherLoop(3)]](/cdn/reader/5a/5aca7ce5b67b7f1d90476f112e0d2182427ae03b1225a3e3a8afb15c189f5ad6/images/page-90.webp?w=400)
5 • Troubleshooting and maintenance Model 6511RC User Manual
Other Loop [sonetOtherLoop(3)] The other loop [sonetOtherLoop(3)] operates much like the facility loop, however the data enters the H.110 framer where it makes a U-turn. The Other Loop test mode (See figure 65) is a factory debugging and hardware test tool intended for use by Patton engineering. The terminal loop and facility loop provide all the functional- ity a Matrix Switch operator should require. Though it is available to Matrix Switch operators, the Other Loop test mode offers no further advantage for testing or troubleshooting in the field.
Figure 65. Other Loopback test mode
SDH section trace and path trace The Matrix Switch supports the section trace and path trace functions specified in the SDH protocol. You can use these trace functions to verify connectivity across an SDH circuit or circuit segment and to validate the link is operating properly. When a trace is enabled, two SDH devices pass a trace message to each other across an SDH link or link segment. When the message arrives without errors the trace succeeds, indicating the connec- tion is healthy. If a device receives a trace message that does not match the expected value, a trace mismatch occurs, indicating an error in the connection.
90 Matrix Switch test tools

Model 6511RC User Manual 5 • Troubleshooting and maintenance
Sections and paths Between a pair of SDH multiplexers, an SDH circuit may comprise multiple cable segments connected by intermediate devices such as signal repeaters and add-drop multiplexers (see figure 66). A cable segment with a regenerator at one or both endpoints is called a section. A set of cable segments with an add-drop multiplexer at one or both endpoints is called a line. An SDH circuit with full-service multiplexers at both endpoints is called a path.

Figure 66. Section, path, and line within an SDH circuit
Section trace The section trace function verifies section connectivity between the two section-terminating nodes.Two SDH section-terminating devices perform the section trace over the STM-1 media segment between them. When section trace is enabled, the SDH frame carries a trace message in either the J0 byte or the section trace string. The value you define for Section Trace Message Length determines which field will carry the Section Trace Mes- sage, as specified below:
To enable section trace:
Matrix Switch test tools 91

5 • Troubleshooting and maintenance Model 6511RC User Manual

Figure 67. Section Trace parameters on the SDH Configuration page
Path trace The path trace function verifies path connectivity between the two path-terminating nodes.The two SDH path-terminating devices perform the trace over the STM-1 media segment between them. When Path Trace is enabled, the SDH frame carries the Path Trace message in either the J1 byte or the path trace string. The value you define for Path Trace Message Length determines which field will carry the Path Trace message, as specified below:
92 Matrix Switch test tools

Model 6511RC User Manual 5 • Troubleshooting and maintenance
Number of paths per frame The STM-1 frame can support one path or three paths, depending on how the STM-1 signal is mapped.
To enable path trace:

Figure 68. Path Trace parameters on the SDH Configuration page
Matrix Switch test tools 93

5 • Troubleshooting and maintenance Model 6511RC User Manual
Consult the rack chassis user manual for information on preventative maintenance (such as cleaning the chassis air cooling vents to remove accumulated dust).
Calibration The Model 6511RC requires no calibration.
This section describes replacing the Model 6511RC.
Replacing the Model 6511RC If you isolate a problem to the a Model 6511RC component, the entire Model 6511RC must be replaced as described in the follow section.
Exporting the current Model 6511RC configuration The 6511RC Matrix Switch provides Import/Export functions. These functions enable you to back up (export) and restore (import) your Matrix Switch’s configuration parameters against possible failure. Should your Matrix Switch ever need replacing, a previously saved copy of your (exported) configuration file can quickly be loaded (imported) into a replacement Matrix Switch.
94 Periodic maintenance

Model 6511RC User Manual 5 • Troubleshooting and maintenance

Figure 69. Import/Export page
Maintenance 95

5 • Troubleshooting and maintenance Model 6511RC User Manual
– On the Import/Export page (figure 69 on page 95) click the Export Flash... hyperlink. The Matrix
Switch will get the configuration file currently stored in your Matrix Switch’s flash memory and display it in your browser (figure 70)
Figure 70. Example Matrix Switch flash memory configuration file displayed in a browser
96 Maintenance

Model 6511RC User Manual 5 • Troubleshooting and maintenance
– To save the displayed data as a text file, use your browser’s Save function (see figure 71). Using Netscape
or Internet Explorer, for example.
Figure 71. Saving the access server flash memory configuration data as a text file
Removing the defective Model 6511RC 1. Remove the replacement Model 6511RC from its shipping container and place it near the chassis in which the malfunctioning Model 6511RC is located.
– The STM-1 WAN cable
– The RS-232 CONFIG cable (if installed)
– The 10/100 Ethernet cable (if installed)
– The two 10/100/1000 Ethernet cables (if installed)
Maintenance 97

5 • Troubleshooting and maintenance Model 6511RC User Manual
Installing the replacement Model 6511RC 1. Insert the replacement Model 6511RC into the rack chassis.
– The STM-1 WAN cable
– The RS-232 CONFIG cable
– The 10/100 Ethernet cable
– The two 10/100/1000 Ethernet cables (if used)
Importing a saved configuration Before importing a saved configuration, you must define the Model 6511RC’s IP address and netmask. These parameters are defined via the Model 6511RC RS-232 CONFIG port on the Model 6511RC.
98 Maintenance

Model 6511RC User Manual 5 • Troubleshooting and maintenance
Upon successfully importing the file, the Model 6511RC will display Configuration Load Complete, indi- cating that the new operating parameters have been loaded into flash memory.
Completing the installation This section verifies that the Model 6511RC is fully operational.
The Model 6511RC is operational.
Maintenance 99

5 • Troubleshooting and maintenance Model 6511RC User Manual
100 Maintenance


6 • Contacting Patton for assistance Model 6511RC User Manual
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems.
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or elephants may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
102 Introduction

Model 6511RC User Manual 6 • Contacting Patton for assistance
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 103

6 • Contacting Patton for assistance Model 6511RC User Manual
104 Warranty Service and Returned Merchandise Authorizations (RMAs)
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| POWER LED (green) is extinguished | To verify that power is being supplied to the Model 6511RC via the CPCI chassis power bus: verify that at least one chassis power supply module is installed in the chassis and functioning normally. | p.82 | |
| POWER LED (green) is flashing | The 6511RC has detected a power failure on a power bus. There may be a prob- lem with the CPCI chassis power system which feeds the Model 6511RC such as a failed power supply module in the chassis. The Model 6511RC will function nor- mally with one power supply. Inspect the power supplies in the CPCI chassis to identify and replace the failed power supply module. If no failed power supply is found, or if the POWER LED continues flashing, contact Patton Technical Support to determine if the Matrix Switch should be replaced. | p.82 | |
| CPU FAIL LED (red) is lit | CPU is unable to load the software from FLASH to RAM for operation. As soon as possible, remove the Model 6511RC from the CPCI chassis, wait 30 seconds, then re-insert the Model 6511RC into the CPCI chassis and see if the problem disap- pears. If the CPU FAIL LED remains lit after the Model 6511RC completes the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch needs to be replaced. | p.82 | |
| ALARM LED (yellow) is lit or flashing | Indicates The 6511RC has detected a minor or major alarm condition. Examine the Alarm System Overview web management page to determine exactly which alarm(s) is(are) active. | p.82 | |
| SYSTEM LED (green) is not flashing | The Model 6511RC is not functioning properly. As soon as possible, force a module power cycle as follows: 1)Wearing an antistatic strap, simultaneously press both red buttons on the front- panel handles of the 6511RC to unlock the handles and prepare the module for removal. 2)Simultaneously press both black handles outward and away from the center of the module to unseat the 6511RC from the mid-plane connectors. 3) Wait 10 seconds. 4)Holding the module by the two black handles, very carefully push the module gently and firmly into the chassis until it is reseated against the midplane. 5)Press the black handle so that they click and lock closed. Once the Matrix Switch has resumed operation re-inspect the SYSTEM LED. If the SYSTEM LED does not begin flashing after completing the power-up cycle, contact Patton Technical Support to determine if the Matrix Switch should be replaced. | p.83 |