User Manual

This is a Class A device and is not intended for use in a residential environment.

Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Trademark Statement The term CopperLink is a trademark of Patton Electronics Company. All other trade-
marks presented in this document are the property of their respective owners.
Copyright © 2014, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton
Electronics assumes no liability for errors that may appear in this document.
Warranty Information Patton Electronics warrants all CopperLink components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from
the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform
as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the
use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or
inability to use this product. Patton Electronics specifically disclaims all other warran-
ties, expressed or implied, and the installation or use of this product shall be deemed
an acceptance of these terms by the user.

1 General information 12
2 Installation 15
3 Configuration 20
4 Operation 24
5 Contacting Patton for assistance 26
A Compliance Information 29
B Specifications 32
C Factory Replacement Parts and Accessories 34
D Interface Pin Assignment 36
E Line Rate & Reach Chart 38


1 Typical applications 14 2 CL1211E/CL1212E rear panel options 16 3 CL1212E (RJ-45) twisted pair line interface 17 4 CL1212E (Terminal Block) twisted pair line interface 18 5 CL1212E 10/100Base-T RJ-45 Connector Pin-out 18 6 Removing protective cover 21 7 DIP switch orientation 21 8 CL1212E front panel 25 9 CL1212E 10/100Base-T RJ-45 Connector Pin-out 37 10 CL1212E RJ-45 Twisted-Pair Line Interface Connector Pin-out 37 11 CL1212E Line Interface Terminal Block Pin-out 37

1 S1 Summary 22 2 Local/Remote Unit Configuration 22 3 Symmetric/Asymmetric Selection Chart 22 4 Signal to Noise Ratio 23 5 Front panel LED description 25 6 Line Rate & Reach Chart Using Twisted-Pair (Long Range) 39 7 Line Rate & Reach Chart Using Twisted-Pair (High Speed) 39

CopperLink 1211E/1212E User Manual About This Guide
This guide describes the CopperLink Model 1211E/1212E hardware, installation, and basic configuration.
This guide is intended for the following users:
This guide contains the following chapters and appendices:
For best results, read the contents of this guide before you install the CopperLink 1212E.
A note presents additional information or interesting sidelights.
The alert symbol and IMPORTANT heading calls attention to important information.

CopperLink 1211E/1212E User Manual About This Guide
The alert symbol and CAUTION heading indicate a potential hazard. Strictly follow the instructions to avoid property dam age.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and WARNING heading indicate a poten tial safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warn ing instructions to avoid injury caused by electric shock.

CopperLink 1211E/1212E User Manual About This Guide
In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.

CopperLink 1211E/1212E User Manual About This Guide
This device contains no user serviceable parts. This device can only be repaired by qualified service personnel.
This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment.
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed cir cuit cards are improperly handled and can result in complete or intermittent failures. Do the following to prevent ESD:


CopperLink 1211E/1212E User Manual 1 • General information
Thank you for purchasing this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical Support at +(301) 975-1007.
Patton Electronics CL1212E Ethernet extenders provide high-speed LAN connections between peered Ether net LANs, remote PCs, or any other network-enabled 10/100Base-T device.
Operating in pairs, one CL1212E is configured as the (L) Local unit located at one end of the LAN extension and the other CL1212E is configured as the (R) Remote unit at the other end. The CL1212E is configured as an L or R via the switch on the bottom of the unit. These units can automatically forward LAN broadcasts, multicasts, and frames across a 2-wire voice-grade twisted-pair. The data is passed transparently (unmodified) through the CL1212E. The CL1212Es automatically add and delete MAC addresses, only passing packets across the Line link that are meant for the remote peered LAN.
Overview 13

CopperLink 1211E/1212E User Manual 1 • General information

Figure 1. Typical applications
The pair of CL1212E models work together to create a transparent extension between two peered Ethernet LANs using twisted pair (2-wire) or Cat5+. Figure 1 shows typical applications.
Description 14


CopperLink 1211E/1212E User Manual 2 • Installation

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.
To install the CL1212E Ethernet Extender, do the following:

Figure 2. CL1211E/CL1212E rear panel options
Planning the Installation 16

CopperLink 1211E/1212E User Manual 2 • Installation
The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.
The CL1212E supports communication between two peer Ethernet LAN sites over a distance of up to 10,000 ft (3 km) over 24 AWG (0.5 mm) twisted-pair wire, Cat5+.
Follow the steps below to connect the CL1212E interfaces.
Connecting the Line Interface for CL1212 1. To function properly, the two CL1212E’s must be connected together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
The RJ-45 connector on the CL1212E’s twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin relationship is shown in figure 3.
1 2 3 4 5 6 7 8
5 (TIP)
Figure 3. CL1212E (RJ-45) twisted pair line interface.
Connecting the Line Interface 17

CopperLink 1211E/1212E User Manual 2 • Installation

Figure 4. CL1212E (Terminal Block) twisted pair line interface

The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.
The RJ-45 ports labeled Eth 0 and Eth 1 are Auto-MDIX 10/100Base-T interfaces. These ports are designed to connect directly to a 10/100Base-T device or network. Figure 5 shows the signal/pin relationships on this inter face. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.

Figure 5. CL1212E 10/100Base-T RJ-45 Connector Pin-out.
Connecting the 10/100Base-T Ethernet Interface 18

CopperLink 1211E/1212E User Manual 2 • Installation
The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.
The CL1212E does not have a power switch, so it powers up as soon as it is plugged in.
An external AC or DC power supply is available separately. This connection is made via the barrel jack on the rear panel of the CL1212E. No configuration is necessary for the power supply.
DC power (supplied via the power supply jack to the CL1212) must meet the following requirements; DC power supplied must be regulated 5 VDC ±5%, 1.0A minimum. Center pin is +5 V. The barrel type plug has 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.
Connecting Power 19


CopperLink 1211E/1212E User Manual 3 • Configuration
The CL1212E has eight DIP switches (S1) for configuring the unit for a wide variety of applications. This sec tion describes switch locations and explains the different configurations.

Figure 6. Removing protective cover

Figure 7. DIP switch orientation
Introduction 21

CopperLink 1211E/1212E User Manual 3 • Configuration
DIP switch S1 is where you configure the Line interface. The following tables describe the configuration for the CL1212E.
Table 1. S1 Summary
Switch S1-1: Local/Remote Configuration Use switch S1-1 to configure the unit as Remote or Local in the CL1212E pair.
Table 2. Local/Remote Unit Configuration
Switches S1-2 and S1-3: Symmetric/Asymmetric Operation Use switches S1-2 and S1-3 to configure the line rate type and operation.
Table 3. Symmetric/Asymmetric Selection Chart
OFF OFF High-Speed “Symmetric”
OFF ON High-Speed “Asymmetric”
ON OFF FastPath High-Speed “Asymmetric”
ON ON Long-Range “Asymmetric”
Configuring DIP Switch S1 22

CopperLink 1211E/1212E User Manual 3 • Configuration
Switch S1-5: General Protection (Signal to Noise Ratio) Use switch S1-5 to configure line noise protection.
Table 4. Signal to Noise Ratio
Configuring DIP Switch S1 23
S1-5 Setting · ON 6dB · OFF 9dB

Introduction 25 Front Panel LED Status Monitors 25

CopperLink 1211E/1212E User Manual 4 • Operation
Once the CL1212Es are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors.
Before applying power to the CL1212E, please review “Connecting Power” on page 19 to verify that the unit is connected to the appropriate power source.
The CL1212E features six front panel LEDs that monitor power, the Ethernet signals, the Line connection, and the remote/local setting. Figure 8 shows the front panel location of each LED. Table 5 on page 25 describes the LED functions.

Figure 8. CL1212E front pan
Table 5. Front panel LED description

Eth 0 and Eth 1 Green The port is connected.
a. Once the unit connects to a power source, the LED will
blink as the CL1212E automatically looks for the other unit in the pair.
el · Introduction 25


CopperLink 1211E/1212E User Manual 5 • Contacting Patton for assistance
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems:
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship ment. All of our products are backed by a comprehensive warranty program.
Warranty Coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Out-of-Warranty Service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro phes may require replacement.
Introduction 27

CopperLink 1211E/1212E User Manual 5 • Contacting Patton for assistance
RMA Numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping Instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 28


CopperLink 1211E/1212E User Manual A • Compliance Information
This device generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufacturer’s instructions-may cause interference to radio and television reception. The device has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the device does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equip ment and receiver are on different branches).
This device is in compliance with the essential requirements and other relevant provisions of Directive 2004/ 108/EC relating to electromagnetic compatibility and Directive 2006/95/EC relating to electrical equipment designed for use within certain voltage limits. The Declaration of Conformity may be obtained from Patton Electronics, Inc at www.patton.com/certifications
The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above directive is indicated by CE mark on the device.
D R M Green European Compliance Services Ltd Greyfriars Court Paradise Square Oxford, OX1 1BE, UK
Regulatory Information 30

CopperLink 1211E/1212E User Manual A • Compliance Information
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:
Packages received without an RMA number will not be accepted.
Service 31


CopperLink 1211E/1212E User Manual B • Specifications
Two-wire unconditioned twisted pair
Operating Temperature Range -40° to 185°F (-40° to 85°C)
Humidity Up to 90% non-condensing.
Optional conformal coating for 85% condensing humidity and protection from corrosion
Dimensions 5.57W x 1.12H x 3.57D in. (14.15W x 2.8H x 9.07D cm) with bracket ears
4.44W x 1.12H x 3.57D in. (11.28 x 2.84H x 9.07D cm) without bracket ears
Line Connector 33

Accessories
CL1211E/CL1212E Factory Replacement Parts and Accessories 35

CopperLink 1211E/1212E User Manual C • Factory Replacement Parts and Accessories
Patton Model # Description
PS-03671H1-004 100–240 VAC (5 V, DC/3 A) Wall mount power adapter
12V- PSM 12 VDC Input Adapter
24V-PSM 24 VDC Input Adapter
48V-PSM 48 VDC Input Adapter
Power Plugs for Universal Input AC Power Supply
12-130 European replacement plug
12-129 American replacement plug
12-131 United Kingdom plug
CL1211E/CL1212E Factory Replacement Parts and Accessories 35


CopperLink 1211E/1212E User Manual D • Interface Pin Assignment

Figure 9. CL1212E 10/100Base-T RJ-45 Connector Pin-out.

Figure 10. CL1212E RJ-45 Twisted-Pair Line Interface Connector Pin-out

Figure 11. CL1212E Line Interface Terminal Block Pin-out
10/100Base-T Interface 37

Line Rate & Reach Chart Based on 24 AWG (0.5 mm) 39

CopperLink 1211E/1212E User Manual E • Line Rate & Reach Chart
Table 6. Line Rate & Reach Chart Using Twisted-Pair (Long Range)

Table 7. Line Rate & Reach Chart Using Twisted-Pair (High Speed)

Asymmetric S1-2 OFF S1-3 ON S1-2 ON S1-3 OFF
Line Rate & Reach Chart Based on 24 AWG (0.5 mm) 39