Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 1 of the Patton electronic 4110 user manual — SmartNode 4520 & 4110 Series VoIP Gateway Routers
Page 1 · click to enlarge
Page 1

SmartNode 4520 & 4110 Series VoIP Gateway Routers

User Manual

Patton electronic 4110 — SmartNode 4520 & 4110 Series VoIP Gateway Routers diagram (page 1)
Fig. 1 · SmartNode 4520 & 4110 Series VoIP Gateway Routers
Sales Office+1 (301) 975-1000 Technical Support: +1 (301) 975-1007
E-mailsupport@ patton.com
WWWwww.patton.com
Part Number07MD4524-GS, Rev. H
RevisedFebruary 9, 2012
Page 2 of the Patton electronic 4110 user manual
Page 2 · click to enlarge
Page 2

Patton Electronics Company, Inc.

7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

tel+1 (301) 975-1000 fax: +1 (301) 869-9293 support: +1 (301) 975-1007
webwww.patton.com e-mail: support@ patton.com

Trademark Statement The terms SmartWare and SmartView are trademarks of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.

Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec tronics assumes no liability for errors that may appear in this document.

Warranty Information The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.

Patton Electronics warrants all SmartNode router components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.

This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

Page 3 of the Patton electronic 4110 user manual — Table of Contents
Page 3 · Contents
Contents

Contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 6 of the Patton electronic 4110 user manual — Structure
Page 6 · click to enlarge
Page 6

About this guide

This guide describes the SmartNode 4110 and 4520 Series hardware, installation and basic configuration. For detailed software configuration information refer to the SmartWare Software Configuration Guide and the avail able Configuration Notes.

Audience

This guide is intended for the following users:

  • Operators
  • Installers
  • Maintenance technicians

Structure

This guide contains the following chapters and appendices:

  • Chapter 1 on page 10 provides information about router features and capabilities
  • Chapter 2 on page 20 contains an overview describing router operation and applications
  • Chapter 3 on page 27 provides quick start hardware installation procedures
  • Chapter 4 on page 38 describes getting started with the SmartNode router
  • Chapter 5 on page 47 contains definitions for the LED status indicators
  • Chapter 6 on page 51 contains information on contacting Patton technical support for assistance
  • Appendix B on page 58 contains specifications for the routers
  • Appendix C on page 64 provides cable recommendations
  • Appendix D on page 70 describes the router’s ports and pin-outs
  • Appendix E on page 73 lists the factory configuration settings for SmartNode 4110 Series devices
  • Appendix F on page 75 lists the factory configuration settings for SmartNode 4520 Series devices
  • Appendix G on page 77 lists the tasks for installing a SmartNode 4520 or 4110 Series router For best results, read the contents of this guide before you install the router.
Page 7 of the Patton electronic 4110 user manual — WARNING
Page 7 · click to enlarge
Page 7

SmartNode 4520 & 4110 Series User Manual About this guide

Precautions

The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.

WARNING

The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.

WARNING

The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.

CAUTION

The alert symbol and CAUTION heading indicate a potential haz ard. Strictly follow the instructions to avoid property damage.

CAUTION

Safety when working with electricity

The SmartNode contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service per sonnel.

WARNING

Mains Voltage: Do not open the case when the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected. The mains outlet that is utilized to power the SmartNode router shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker.

WARNING

For AC powered units, ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.

WARNING

Page 8 of the Patton electronic 4110 user manual — CAUTION
Page 8 · click to enlarge
Page 8

SmartNode 4520 & 4110 Series User Manual About this guide

For units with an external power adapter, the adapter shall be a listed Lim ited Power Source.

WARNING

Hazardous network voltages are present in WAN ports regardless of whether power to the SmartNode is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the SmartNode first.

WARNING

Before opening the chassis, disconnect the telephone network cables to avoid contact with telephone line voltages. When detaching the cables, detach the end away from the SmartNode first.

WARNING

Do not work on the system or connect or disconnect cables during periods of lightning activity.

WARNING

In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.

Preventing electrostatic discharge damage When starting to install interface cards place the interface card on its shielded plastic bag if you lay it on your bench.

Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermit tent failures. Do the following to prevent ESD:

CAUTION

  • Always follow ESD prevention procedures when removing and replacing cards.
  • Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.
  • To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
Page 9 of the Patton electronic 4110 user manual — Typographical conventions used in this document
Page 9 · click to enlarge
Page 9

SmartNode 4520 & 4110 Series User Manual About this guide

  • General observations
  • Clean the case with a soft slightly moist anti-static cloth
  • Place the unit on a flat surface and ensure free air circulation
  • Avoid exposing the unit to direct sunlight and other heat sources
  • Protect the unit from moisture, vapors, and aggressive liquids

Typographical conventions used in this document

This section describes the typographical conventions and terms used in this guide.

General conventions The procedures described in this manual use the following text conventions:

Table 1. General conventions

ConventionMeaning Garamond blue typeIndicates a cross-reference hyperlink that points to a figure, graphic, table, or sec tion heading. Clicking on the hyperlink jumps you to the reference. When you have finished reviewing the reference, click on the Go to Previous View button in the Adobe® Acrobat® Reader toolbar to return to your starting point. Futura bold typeCommands and keywords are in boldface font. Futura bold-italic typeParts of commands, which are related to elements already named by the user, are in boldface italic font. Italicized Futura typeVariables for which you supply values are in italic font Futura typeIndicates the names of fields or windows. Garamond bold typeIndicates the names of command buttons that execute an action. < >Angle brackets indicate function and keyboard keys, such as <SHIFT>, <CTRL>, <C>, and so on. [ ]Elements in square brackets are optional. {a | b | c}Alternative but required keywords are grouped in braces ({ }) and are separated by vertical bars ( | ) blue screenInformation you enter is in blue screen font. screenTerminal sessions and information the system displays are in screen font. nodeThe leading IP address or nodename of a SmartNode is substituted with node in boldface italic font. SNThe leading SN on a command line represents the nodename of the SmartNode #An hash sign at the beginning of a line indicates a comment line.
Page 10 of the Patton electronic 4110 user manual — Table of contents
Page 10 · click to enlarge
Page 10

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 11 of the Patton electronic 4110 user manual — SmartNode Series VoIP routers overview
Page 11 · click to enlarge
Page 11

SmartNode 4520 & 4110 Series User Manual 1 • General information

SmartNode Series VoIP routers overview

The SmartNode 4520 and 4110 Series VoIP Gateway Routers (see figure 1) combine IP routing, VPN/Secu rity, and Quality of Service for up to 8 transparent voice and FAX calls over any IP or PSTN network. Leverage low-cost IP services with packet-voice for complete branch office voice and data connectivity.

Patton electronic 4110 — SmartNode Series VoIP routers overview diagram (page 11)
Fig. 2 · SmartNode Series VoIP routers overview

Figure 1. SmartNode Router (SmartNode 4524 shown)

The SmartNode 4520 Series Gateway Routers, equipped with two 10/100Base-T Ethernet ports provide; voice over IP (VoIP) and Internet telephony plus Internet access routing, VPN and firewall functions, and extensive Quality of Service (QoS) functions.

The SmartNode 4110 Series Media Gateways, equipped with a single 10/100Base-T Ethernet port that pro vide VoIP and Internet telephony.

The SmartNode VoIP Gateways and Gateway-Routers perform the following major functions:

  • Voice over IP and local switching via a combination of 2 to 8 analog phone ports (FXS) and 2 to 4 analog line ports (FXO).
  • Standard compliant VoIP conversion in accordance with SIP and H.323 protocols.
  • Internet access and IP Routing (4520 Series only) with IP Quality of Service (QoS) support for mixed voice and data traffic.

Section “SmartNode 4520 Series router” on page 12 provides more information on the SmartNode 4520 Series. Section “SmartNode 4110 Series router” on page 16 describes the SmartNode 4110 Series.

SmartNode Series VoIP routers overview 11

Page 12 of the Patton electronic 4110 user manual — SmartNode 4520 Series router
Page 12 · click to enlarge
Page 12

SmartNode 4520 & 4110 Series User Manual 1 • General information

SmartNode 4520 Series router The SmartNode 4520 Series are compact VoIP Gateway Routers that support two to eight VoIP calls and var ious combinations of FXS and FXO ports (see figure 2).

Patton electronic 4110 — SmartNode 4520 Series router diagram (page 12)
Fig. 3 · SmartNode 4520 Series router

Figure 2. Examples of SN4520 Series rear panels

The following base models (each equipped with two 10/100Base-T Ethernet ports) are available:

  • SmartNode 4522 (2 VoIP calls)
  • SmartNode 4524 (4 VoIP calls)
  • SmartNode 4526 (6 VoIP calls)
  • SmartNode 4528 (8 VoIP calls)

SmartNode Series VoIP routers overview 12

Page 13 of the Patton electronic 4110 user manual — SmartNode 4520 Series router
Page 13 · click to enlarge
Page 13

SmartNode 4520 & 4110 Series User Manual 1 • General information

The port combinations are indicated in the extension of the model code. The products the following model code conventions apply:

  • JS stands for FXS ports
  • JO stands for FXO ports
  • UI stands for integrated universal input power supply (see figure 3 )
  • EUI stands for external universal input power supply (see figure 3 )

For example, the model code SN4526/4JS2JO/EUI describes a SmartNode configured as follows:

  • 4 FXS ports
  • 2 FXO ports
  • External power supply
Patton electronic 4110 — SmartNode 4520 Series router diagram (page 13)
Fig. 4 · SmartNode 4520 Series router

Figure 3. SmartNode 4520 Series power input connectors

SmartNode Series VoIP routers overview 13

Page 14 of the Patton electronic 4110 user manual — ETH 0/0 & ETH 0/1
Page 14 · click to enlarge
Page 14

SmartNode 4520 & 4110 Series User Manual 1 • General information

Ports descriptions The SmartNode 4520 Series rear panel ports are described in table 2.

Table 2. Rear panel ports

Rear panel RJ-45 connectors (see figure 16 on page 32) that connect the router to an

ETH 0/0 & ETH 0/1

Ethernet device (e.g., a cable or DSL modem, LAN hub or switch).

Analog voice port, FXS

Rear panel FXS RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that

connect the router with an analog terminal (a telephone, for example) FXO port. EuroPOTS support (ETSI EG201 188). FXS on-hook voltage is 48V for each FXS port.

Analog voice port, FXO

Rear panel FXO RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that

connect the router with an analog line (FXS port). EuroPOTS support (ETSI EG201 188).

Power Rear panel The gateway is available in a DC or AC power input version (see

figure 3), labeled as follows:

  • AC version (Internal power supply): 100–240 VAC, 50/60 Hz, 200 mA
  • DC version: 12 VDC, 1.25 A

Console Front panel Used for service and maintenance, the Console port (see figure 4 on page 15),

an RS-232 RJ-45 connector, connects the router to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal).

Reset button behavior For those SmartNode devices that have a Reset button on the rear panel, its behavior is as follows:

  • To restart the unit with the current startup configuration—Press for less than 1 second and release the Reset button. The SmartNode will restart with the current startup configuration.
  • To restart the unit with factory default configuration—Press the Reset button for 5 seconds until the Power LED starts blinking. The unit will restart with factory default configuration.
  • To restart the unit in bootloader mode (to be used only by trained SmartNode technicians)—Start with the unit powered off. Press and hold the Reset button while applying power to the unit. Release the Reset button when the Power LED starts blinking so the unit will enter bootloader mode.

SmartNode Series VoIP routers overview 14

Port Location Description · 10/100 Ethernet

Page 15 of the Patton electronic 4110 user manual — Ports descriptions
Page 15 · click to enlarge
Page 15

SmartNode 4520 & 4110 Series User Manual 1 • General information

Patton electronic 4110 — Ports descriptions diagram (page 15)
Fig. 5 · Ports descriptions

Figure 4. SmartNode 4520 Series front panels

SmartNode Series VoIP routers overview 15

Page 16 of the Patton electronic 4110 user manual — SmartNode 4110 Series router
Page 16 · click to enlarge
Page 16

SmartNode 4520 & 4110 Series User Manual 1 • General information

SmartNode 4110 Series router The SmartNode 4110 Series are compact VoIP Gateways that support two to eight VoIP calls and various combinations of FXS and FXO ports (see figure 5).

Patton electronic 4110 — SmartNode 4110 Series router diagram (page 16)
Fig. 6 · SmartNode 4110 Series router

Figure 5. Examples of SN4110 Series rear panels

The following base models (each equipped with one 10/100Base-T Ethernet port) are available:

  • SmartNode 4112 (2 VoIP calls)
  • SmartNode 4114 (4 VoIP calls)
  • SmartNode 4116 (6 VoIP calls)
  • SmartNode 4118 (8 VoIP calls)

SmartNode Series VoIP routers overview 16

Page 17 of the Patton electronic 4110 user manual — SmartNode 4110 Series router
Page 17 · click to enlarge
Page 17

SmartNode 4520 & 4110 Series User Manual 1 • General information

The port combinations are indicated in the extension of the model code. The products the following model code conventions apply:

  • JS stands for FXS ports
  • JO stands for FXO ports
  • UI stands for integrated universal input power supply (see figure 6 )
  • EUI stands for external universal input power supply (see figure 6 )

For example, the model code SN4116/4JS2JO/EUI describes a SmartNode configured as follows:

  • 4 FXS ports
  • 2 FXO ports
  • External power supply
Patton electronic 4110 — SmartNode 4110 Series router diagram (page 17)
Fig. 7 · SmartNode 4110 Series router

Figure 6. SmartNode 4110 Series power input connectors

SmartNode Series VoIP routers overview 17

Page 18 of the Patton electronic 4110 user manual — ETH 0/0
Page 18 · click to enlarge
Page 18

SmartNode 4520 & 4110 Series User Manual 1 • General information

Ports descriptions The SmartNode 4110 Series rear panel ports are described in table 3.

Table 3. Rear panel ports

Rear panel RJ-45 connector (see figure 5 on page 16) that connects the router to an

ETH 0/0

Ethernet device (a cable or DSL modem, LAN hub or switch, for example).

Analog voice port, FXS

Rear panel FXS RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that

connect the router with an analog terminal (a telephone, for example) FXO port. EuroPOTS support (ETSI EG201 188).

Analog voice port, FXO

Rear panel FXO RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that

connect the router with an analog line (FXS port). EuroPOTS support (ETSI EG201 188).

Power Rear panel The gateway is available in a DC or AC power input version (see

figure 6), labeled as follows:

  • AC version (Internal power supply): 100–240 VAC, 50/60 Hz, 200 mA
  • DC version: 12 VDC, 1.25 A

Console Front panel Used for service and maintenance, the Console port (see figure 7 on page 19),

an RS-232 RJ-45 connector, connects the router to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal).

Reset button behavior For those SmartNode devices that have a Reset button on the rear panel, its behavior is as follows:

  • To restart the unit with the current startup configuration—Press for less than 1 second and release the Reset button. The SmartNode will restart with the current startup configuration.
  • To restart the unit with factory default configuration—Press the Reset button for 5 seconds until the Power LED starts blinking. The unit will restart with factory default configuration.
  • To restart the unit in bootloader mode (to be used only by trained SmartNode technicians)—Start with the unit powered off. Press and hold the Reset button while applying power to the unit. Release the Reset button when the Power LED starts blinking so the unit will enter bootloader mode.

SmartNode Series VoIP routers overview 18

Port Location Description · 10/100 Ethernet

Page 19 of the Patton electronic 4110 user manual — Ports descriptions
Page 19 · click to enlarge
Page 19

SmartNode 4520 & 4110 Series User Manual 1 • General information

Patton electronic 4110 — Ports descriptions diagram (page 19)
Fig. 8 · Ports descriptions

Figure 7. SmartNode 4110 Series front panels

SmartNode Series VoIP routers overview 19

Page 20 of the Patton electronic 4110 user manual — Table of contents
Page 20 · click to enlarge
Page 20

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 21 of the Patton electronic 4110 user manual — Applications for SmartNode 4110 Series
Page 21 · click to enlarge
Page 21

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview

Introduction

Patton’s SmartNode Media Gateway Routers deliver the features you need for advanced multiservice voice and data network applications. They combine high quality voice-over-IP with powerful quality of service routing functions to build professional and reliable VoIP networks. This chapter describes typical applications for which the SmartNodes are uniquely suited.

Applications for SmartNode 4110 Series

The SmartNode 4110 Series device, equipped with a single Ethernet port, provides gateway and over-IP line extension services.

SIP and H.323 terminal and PSTN gateways All models provide voice-over-IP and FAX-over-IP services for integration into a VoIP network running the SIP or H.323 protocol (see figure 8). The SmartNode 4110 Series supports automatic registration to a Gatekeeper or SIP server to provide analog extension services or PSTN breakout connectivity.

Patton electronic 4110 — Applications for SmartNode 4110 Series diagram (page 21)
Fig. 9 · Applications for SmartNode 4110 Series

Figure 8. PSTN and Terminal gateways

Introduction 21

Page 22 of the Patton electronic 4110 user manual — Application-Analog line extension over IP
Page 22 · click to enlarge
Page 22

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview

Application—Analog line extension over IP A virtual analog line can be created using an FXO and FXS model (see figure 9). The complete signaling and media (voice, fax, or modem) of the analog phone line is extended over IP. This enables a PBX analog exten sion line to be extended to a home office or satellite office. The analog line extension relays DTMF, hook-flash and CLI to provide full PBX feature access over the IP network (checking voice mail or joining a calling group, for example).

Patton electronic 4110 — Application-Analog line extension over IP diagram (page 22)
Fig. 10 · Application-Analog line extension over IP

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

Figure 9. Analog line extension

Application—ITSP dial-in access An ITSP can use the SmartNode FXO gateways as dial-in access points to his Internet telephony services (see figure 10). A user calls a local number, the FXO SmartNode picks up the call and uses a second dial-tone to dial the remote number. The system can be enhanced with a central call control server providing IVR announcements, PIN checking, and accounting for the calls.

Patton electronic 4110 — Application-Analog line extension over IP diagram (page 22)
Fig. 11 · Application-Analog line extension over IP

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

Figure 10. ITSP dial-in access

Applications for SmartNode 4110 Series 22

Page 23 of the Patton electronic 4110 user manual — Application-Private line automatic ringdown (PLAR)
Page 23 · click to enlarge
Page 23

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview

Application—Private line automatic ringdown (PLAR) A private hot-line can be created by using two FXS models back-to-back (see figure 11). These can be found in use as courtesy phones at ATM’s, information kiosks, and emergency assistance pedestals. In this applica tion, when one handset is picked-up, the remote handset immediately begins ringing. When the remote handset is picked-up, the speech path is completed. The end-to-end link supports voice, fax Gr.3 (2.4–14.4 kbps) with T.38 or fax- and modem bypass using a G.711 codec.

Patton electronic 4110 — Application-Private line automatic ringdown (PLAR) diagram (page 23)
Fig. 12 · Application-Private line automatic ringdown (PLAR)

Figure 11. FXS to FXS Hotline

Application—Enterprise campus BRI to FXS telephony extension In combination with the Patton SmartNode 1000 and 2000 Series models the FXS gateways provide ISDN BRI to FXS extensions over IP (see figure 12).

Patton electronic 4110 — Application-Private line automatic ringdown (PLAR) diagram (page 23)
Fig. 13 · Application-Private line automatic ringdown (PLAR)

Figure 12. BRI to FXS extension

Applications for SmartNode 4110 Series 23

Page 24 of the Patton electronic 4110 user manual — Applications for SmartNode 4520 Series
Page 24 · click to enlarge
Page 24

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview

Application—PBX toll bypass gateway The gateways can be used to provide toll bypass over an IP WAN (see figure 13). The call routing in this case is provided by the PBX systems. A call routed to the FXS gateway can be relayed on a port-to-port basis or depending on the dialed-number to the remote gateway.

Patton electronic 4110 — Application-PBX toll bypass gateway diagram (page 24)
Fig. 14 · Application-PBX toll bypass gateway

Figure 13. Toll bypass

Applications for SmartNode 4520 Series

SmartNode 4520 Series devices have dual 10/100Base-T Ethernet ports. The two Ethernet ports provide full featured IP routing between LAN and WAN plus Ethernet and IP layer QoS services. Voice prioritization and traffic management avoid network congestion and provide optimal voice quality. With these additional fea tures the SmartNode 4520 series can add Internet access and data networking to any of the SmartNode 4110 Series applications described previously. The following sections show some typical combined voice- data applications.

Applications for SmartNode 4520 Series 24

Page 25 of the Patton electronic 4110 user manual — Application-SOHO off-premise extension
Page 25 · click to enlarge
Page 25

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview

Application—SOHO off-premise extension For a SOHO/telecommuter, the SmartNode 4520 Series router can provide an off-premise extension to the corporate network (see figure 14). Along with the analog line extension features, the SmartNode provides Internet access and VPN connectivity to the main office. In this configuration, the remote user will appear to be local and can take advantage of services available to local telephony and LAN users (such as file-server access, station-to-station dialing, outside trunk access, and voice mail). Additionally, the home user can take advantage of corporate dialing rates.

Patton electronic 4110 — Application-SOHO off-premise extension diagram (page 25)
Fig. 15 · Application-SOHO off-premise extension

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

Figure 14. Home office networking

Applications for SmartNode 4520 Series 25

Page 26 of the Patton electronic 4110 user manual — Application-Single-phone PSTN and VoIP access
Page 26 · click to enlarge
Page 26

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview

Application—Single-phone PSTN and VoIP access The SmartNode 4520 Series with a combination of FXS and FXO ports can be used to make and receive calls via PSTN and Internet calling services over the same telephone handset (see figure 15). Using individually con figurable routing tables, an outbound call can be directed to the local PSTN connection or to an Internet tele phony service provider (ISTP). Inbound calls from the Internet and the PSTN can ring the same phone.

Patton electronic 4110 — Application-Single-phone PSTN and VoIP access diagram (page 26)
Fig. 16 · Application-Single-phone PSTN and VoIP access

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

Figure 15. Single-phone access

Applications for SmartNode 4520 Series 26

Page 27 of the Patton electronic 4110 user manual — Table of contents
Page 27 · click to enlarge
Page 27

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 28 of the Patton electronic 4110 user manual — Planning the installation
Page 28 · click to enlarge
Page 28

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Planning the installation

Before you start the actual installation, it is strongly recommended that you gather all the information needed to install and setup the device. See table 4 for an example of what pre-installment checks you might need to carry out. Having carried out the pre-installation checks enables you to install and set up your gateway router into an existing infrastructure with confidence.

The mains outlet that is utilized to power the equipment must be within 1 foot (3 meters) of the device and shall be easily accessible. CAUTION

Before installing the gateway router device, the following tasks should be completed:

  • Create a network diagram (see section “Network information” on page 30)
  • Gather IP related information (see section “IP related information” on page 30 for more information)
  • Install the hardware and software needed to configure the SmartNode . (See section “Software tools” on page 30)
  • Verify power source reliability (see section “Power source” on page 30).

When you finish preparing for gateway router installation, go to section “Installing the gateway router” on page 31 to install the device.

Planning the installation 28

Page 29 of the Patton electronic 4110 user manual — Installation checklist
Page 29 · click to enlarge
Page 29

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Installation checklist The installation checklist (see table 4) lists the tasks for installing a SmartNode 4520 or 4110 Series router. Make a copy of this checklist and mark the entries as you complete each task. For each SmartNode 4520 or 4110 Series router, include a copy of the completed checklist in your site log.

Table 4. Installation checklist

Task Verified by Date

Network information available & recorded in site log

Site power voltages verified

Installation site pre-power check completed

All printed documents available

SmartWare release & build number verified

Rack, desktop, or wall mounting of chassis completed

Initial electrical connections established

ASCII terminal attached to console port

Cable length limits verified

Planning the installation 29

Show 5 more labels / short text on this page
Environmental specifications verified · Required tools available · Additional equipment available · Initial configuration performed · Initial operation verified
Page 30 of the Patton electronic 4110 user manual — Site log
Page 30 · click to enlarge
Page 30

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Site log Patton recommends that you maintain a site log to record all actions relevant to the system, if you do not already keep such a log. Site log entries should include information such as listed in table 5.

Table 5. Sample site log entries

Installation Make a copy of the installation checklist and insert it into the site log

Upgrades and maintenance Use the site log to record ongoing maintenance and expansion history

Configuration changes Record all changes and the reasons for them

Maintenance Schedules, requirements, and procedures performed

Comments Notes, and problems

Software Changes and updates to SmartWare software

Network information Network connection considerations that you should take into account for planning are provided for several types of network interfaces are described in the following sections.

Network Diagram Draw a network overview diagram that displays all neighboring IP nodes, connected elements and telephony components.

IP related information Before you can set up the basic IP connectivity for your SmartNode 4000 series you should have the following information:

  • IP addresses used for Ethernet LAN and WAN ports
  • Subnet mask used for Ethernet LAN and WAN ports
  • IP addresses of central H.323 Gatekeeper (if used)
  • IP addresses of central PSTN Gateway for H.323 and/or ISoIP based calls
  • IP addresses of central TFTP Server used for configuration upload and download

Software tools You will need a PC (or equivalent) with a VT-100 emulation program (e.g. HyperTerminal) to configure the software on your SmartNode router.

Power source If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery with large motors nearby, have a qualified professional test the power. Install a power conditioner if necessary.

Planning the installation 30

Entry Description

Page 31 of the Patton electronic 4110 user manual — CAUTION
Page 31 · click to enlarge
Page 31

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Location and mounting requirements The SmartNode router is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables. Allow sufficient space at the rear of the chassis for cable connections. Additionally, you should consider the need to access the unit for future upgrades and maintenance.

Installing the gateway router SmartNode gateway router installation consists of the following:

  • Placing the device at the desired installation location (see section “Mounting the gateway router” on page 31)
  • Installing the interface and power cables (see section “Connecting cables” on page 31)

When you finish installing the SmartNode, go to chapter 4, “Getting started with the SmartNode” on page 38.

Mounting the gateway router Place the router on a desktop or similar sturdy, flat surface that offers easy access to the cables. The router should be installed in a dry environment with sufficient space to allow air circulation for cooling.

Connecting cables

Do not work on the system or connect or disconnect cables during periods of lightning activity.

WARNING

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.

CAUTION

Installing router cables takes place in the following order:

1. Installing the RJ-11 voice port (FXS) cable or cables (see “Installing an interface cable on the router’s FXS and FXO interface ports”)
2. Installing the 10/100 Ethernet port cable or cables (see “Installing the Ethernet cable” on page 34)
3. Installing the power input (see “Connecting to external power source” on page 36)

Installing the gateway router 31

Page 32 of the Patton electronic 4110 user manual — Installing an interface cable on the router’s FXS and FXO interface ports
Page 32 · click to enlarge
Page 32

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Installing an interface cable on the router’s FXS and FXO interface ports The gateway comes with at least two FXS or FXO analog ports—or a combination of FXS and FXO ports—(see figure 16) located on the back of the router. The FXS interfaces are connected to analog devices via cables (see figure 17) terminated with RJ-11 connectors (see figure 19 and table 6 on page 33 for pin-out information). The FXO interface connects the router with analog lines via cables (see figure 18 on page 33) terminated with RJ-11 connectors (see figure 19 and table 6 on page 33 for pin-out information).

Patton electronic 4110 — Installing an interface cable on the router’s FXS and FXO interface ports diagram (page 32)
Fig. 17 · Installing an interface cable on the router’s FXS an…

Figure 16. Rear view showing location of Ethernet and FXS connectors (SmartNode 4520 shown)

Figure 17. Analog FXS connection

Installing the gateway router 32

Page 33 of the Patton electronic 4110 user manual — Installing an interface cable on the router’s FXS and FXO interface ports
Page 33 · click to enlarge
Page 33
Patton electronic 4110 — Installing an interface cable on the router’s FXS and FXO interface ports diagram (page 33)
Fig. 18 · Installing an interface cable on the router’s FXS an…

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Figure 18. Analog FXO connection

Patton electronic 4110 — Installing an interface cable on the router’s FXS and FXO interface ports diagram (page 33)
Fig. 19 · Installing an interface cable on the router’s FXS an…

Figure 19. RJ-11 pinout diagram

Table 6. RJ-11 socket

Installing the gateway router 33

Pin Signal · 3 Ring (-) · 4 Tip (+)

Page 34 of the Patton electronic 4110 user manual — 1 TX+
Page 34 · click to enlarge
Page 34

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Installing the Ethernet cable The SmartNode 4520 Series has automatic MDX (auto-cross-over) detection and configuration on the Ether net ports. Any of the two ports can be connected to a host or hub/switch with a straight-through wired cable (see figure 20 on page 34). Ethernet devices (10Base-T or 100Base-T) are connected to the SmartNode’s Ethernet ports (see table 7 for port pin-out listing) via a cable terminated with RJ-45 plugs. Because the Smart Node 4110 Series does not have the MDX feature, a cross-over cable is required when connecting SmartNode 4110 Series devices to a host (see figure 21 on page 35).

Table 7. Ethernet 10/100Base-T (RJ-45) port pin-outs (SmartNode 4110 Series)

1 TX+

2 TX-

3 RX+

6 RX-

Patton electronic 4110 — 1 TX+ diagram (page 34)
Fig. 20

Figure 20. Connecting a SmartNode 4110 Series device to a hub

Installing the gateway router 34

Pin Signal

Page 35 of the Patton electronic 4110 user manual — Installing the Ethernet cable
Page 35 · click to enlarge
Page 35

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Patton electronic 4110 — Installing the Ethernet cable diagram (page 35)
Fig. 21 · Installing the Ethernet cable

Figure 21. Connecting to a host (cross-over cable required for SmartNode 4110 Series only)

Installing the gateway router 35

Page 36 of the Patton electronic 4110 user manual — Connecting to external power source
Page 36 · click to enlarge
Page 36

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Connecting to external power source

Patton electronic 4110 — Connecting to external power source diagram (page 36)
Fig. 22 · Connecting to external power source

The terminal block header to which the wires are secured pro vides the disconnect for the SmartNode. Take proper measures to ensure that it is not permanently fastened to the receptacle mounted on the chassis. CAUTION

The router comes with an internal or external power supply. This section describes installing the power cord into the router. Do the following:

1. If your unit is equipped with an internal power supply, go to step 2. Otherwise, insert the barrel type con nector end of the AC power cord into the external power supply connector (see figure 22 ).
2. Insert the female end of the power cord into the internal power supply connector (see figure 22 ).
Patton electronic 4110 — Connecting to external power source diagram (page 36)
Fig. 23 · Connecting to external power source

Figure 22. Power connector location on rear panel

Installing the gateway router 36

Page 37 of the Patton electronic 4110 user manual — Connecting to external power source
Page 37 · click to enlarge
Page 37

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Patton electronic 4110 — Connecting to external power source diagram (page 37)
Fig. 24 · Connecting to external power source

The router power supply automatically adjusts to accept an input voltage from 100 to 240 VAC (50/60 Hz).

Verify that the proper voltage is present before plugging the power cord into the receptacle. Failure to do so could result in equipment damage.

3. Verify that the AC power cord included with your router is compatible with local standards. If it is not, refer to “Contacting Patton for assistance” on page 51 to find out how to replace it with a compatible power cord.
4. Connect the male end of the power cord to an appropriate power outlet.
Patton electronic 4110 — Connecting to external power source diagram (page 37)
Fig. 25 · Connecting to external power source

Figure 23. Router front panel LEDs and Console port locations (SmartNode 4524 shown)

5. Verify that the green Power LED is lit (see figure 23 ).

Congratulations, you have finished installing the SmartNode Gateway Router! Now go to chapter 4, “Getting started with the SmartNode” on page 38.

Installing the gateway router 37

Page 38 of the Patton electronic 4110 user manual — Table of contents
Page 38 · click to enlarge
Page 38

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 39 of the Patton electronic 4110 user manual — Introduction
Page 39 · click to enlarge
Page 39

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

Introduction

This chapter leads you through the basic steps to set up a new SmartNode and to download a configuration.

Patton SmartNodes can be used for a wide variety of IP-based network applications. To support and ease the configuration of the SmartNodes configuration, templates for the most important applications are available on the Patton server at www.patton.com/voip

The main steps for setting up a new SmartNode (as of release 2.00 or 2.10) are shown in figure 24.

Patton electronic 4110 — Introduction diagram (page 39)
Fig. 26 · Introduction

Figure 24. Steps for setting up a new SmartNode

Introduction 39

Page 40 of the Patton electronic 4110 user manual — 1. Configure IP address
Page 40 · click to enlarge
Page 40

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

1. Configure IP address

Patton electronic 4110 — 1. Configure IP address diagram (page 40)
Fig. 27 · 1. Configure IP address

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.

Power connection and default configuration First the SmartNode must be connected to the mains power supply with the power cable. Wait until the 'Run' LED stops blinking and lights constantly. Now the SmartNode is ready.

The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 8.

Table 8. Factory default IP address and network mask configuration

Patton electronic 4110 — 1. Configure IP address diagram (page 40)
Fig. 28 · 1. Configure IP address

Both Ethernet interfaces are activated upon power-up.

If these addresses match with those of your network, go to section “2. Connect the SmartNode to the network” on page 42. Otherwise, refer to the following sections to change the addresses and network masks.

Connect with the serial interface The Console port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and cable (see figure 25) between the SmartNode’s Console port and a PC or workstation’s RS-232 serial interface. Activate the terminal emulation program on the PC or workstation that supports the serial interface (e.g. HyperTerm).

Patton electronic 4110 — 1. Configure IP address diagram (page 40)
Fig. 29 · 1. Configure IP address

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

Figure 25. Connecting to the terminal

  • Terminal emulation program settings:
  • 9600 bp
  • no parity
1. Configure IP address 40
Page 41 of the Patton electronic 4110 user manual — Login
Page 41 · click to enlarge
Page 41

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

  • 8 bit
  • 1 stop bit
  • No flow control

Login Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to display. Type the factory default login: administrator and leave the password empty. Press the Enter key after the pass word prompt.

login:administrator

password<Enter>

172.16.40.1> After you have successfully logged in you are in the operator execution mode, indicated by > as command line prompt. With the commands enable and configure you enter the configuration mode.

172.16.40.1>enable

172.16.40.1#configure

172.16.40.1(cfg)#

Changing the IP address Select the context IP mode to configure an IP interface.

172.16.40.1(cfg)#context ip router

172.16.40.1(ctx-ip)[router]# Now you can set your IP address and network mask for the interface eth0. Within this example a class C net work (172.16.1.0/24) is assumed. The IP address in this example is set to 172.16.1.99 (you should set this to an unused IP address on your network).

172.16.40.1(ctx-ip)[router]#interface eth0

172.16.40.1(if-ip)[eth0]#ipaddress 172.16.1.99 255.255.255.0

2002-10-29T00:09:40 : LOGINFO : Link down on interface eth0.

2002-10-29T00:09:40 : LOGINFO : Link up on interface eth0.

172.16.1.99(if-ip)[eth0]# Copy this modified configuration to your new start-up configuration. Upon the next start-up the system will initialize itself using the modified configuration.

172.16.1.99(if-ip)[eth0]#copy running-config startup-config

172.16.1.99(if-ip)[eth0]# The SmartNode can now be connected with your network.

1. Configure IP address 41
Page 42 of the Patton electronic 4110 user manual — 3. Load configuration
Page 42 · click to enlarge
Page 42

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

2. Connect the SmartNode to the network

Patton electronic 4110 — 2. Connect the SmartNode to the network diagram (page 42)
Fig. 30 · 2. Connect the SmartNode to the network

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Depending whether you connect the SmartNode to a host directly or via a hub or switch either straight- through wired or cross-over cables must be used (see figure 26).

Patton electronic 4110 — 2. Connect the SmartNode to the network diagram (page 42)
Fig. 31 · 2. Connect the SmartNode to the network

Figure 26. Connecting the SmartNode to the network

You can check the connection with the ping command to another host on the local LAN.

172.16.1.99(if-ip)[eth0]#ping Respectively from the host: ping 172.16.1.99

3. Load configuration

Download a configuration note to your PC from the support page of Patton’s Inalp web server (http://www.inalp.ch/en/support/confignotes/) that matches your application. Adapt the configuration as described in the configuration note to your network (do not forget to modify the IP address) and copy the modified configuration to a TFTP server. The SmartNode can now load its configuration from this server.

In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration named SN.cfg in the root directory of the TFTP server.

172.16.1.99(if-ip)[eth0]#copy tftp://172.16.1.11/SN.cfg startup-config

Download...100%

2. Connect the SmartNode to the network 42
Page 43 of the Patton electronic 4110 user manual — Bootloader
Page 43 · click to enlarge
Page 43

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

172.16.1.99(if-ip)[eth0]# After the SmartNode has been rebooted the new start up configuration will be activated.

172.16.1.99(if-ip)[eth0]#reload

Running configuration has been changed.

Do you want to copy the 'running-config' to the 'startup-config'?

Press 'yes' to store, 'no' to drop changes : no

Press 'yes' to restart, 'no' to cancel : yes

The system is going down

Bootloader

The bootloader ensures that basic operations, network access, and downloads are possible in case of interrupted or corrupted application image downloads. It also offers console access to the Bootloader and the capability for downloading application images (e.g. SmartWare) via the serial link of the console.

Start Bootloader To start the Bootloader, power on the SmartNode while pressing the reset button. Open a Telnet session to the SmartNode via one of the Ethernet interfaces, or open a CLI session via the console port (if available on the SmartNode). The login display will appear. Using the credentials admin / patton, log in to the SmartNode. The following prompt will be displayed:

Type help to display an overview of the available commands.

RedBoot> · Bootloader 43

Page 44 of the Patton electronic 4110 user manual — Start-up with factory configuration
Page 44 · click to enlarge
Page 44

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

Start-up with factory configuration

1 RedBoot> fis load Copies the SmartWare application image from the persistent memory (flash:) to the volatile memory (RAM) from where it will be executed.

2 RedBoot> go -s factory-config Starts the SmartWare application telling it to use ‘factory-config’ as startup configuration. You can also start-up with any other configuration available in the persistent memory (nvram:) by pro viding its name instead of ‘factory-config’.

Load a new application image (SmartWare) via TFTP The following procedure downloads the application image (SmartWare) for the mainboard. See the note below on how to download the respective CLI description file.

RedBoot> ip_address - l local_ip_address [/mask_len]

Sets the IP address and subnet mask of the Ethernet interface 0/0 which shall be used to receive the new application image. mask_len is the length of the network address (or the number of 1’s within the subnet mask). See Note below.

RedBoot> ip_address -g gateway Sets the IP address of the default gateway.

RedBoot> ping -h tftp-server_ip_address Tests the connectivity to the TFTP server.

4 RedBoot> load -r -v -h host -b base_address file_name

Downloads an application image into the vola tile memory (RAM) from where the SmartNode could directly execute it. host: IP address of the TFTP server base_address: memory location where to store the application image. Use the default address 0x1800100 file_name: path and name of the file on the TFTP server. Note: use the image file that con tains the whole application, not the image parts.

5 RedBoot> fis delete -n 1 Deletes the first application image. Reply with ‘y’ to the confirmation request.

6 RedBoot> fis create Stores the downloaded application image to the permanent memory (flash:). Reply with ‘y’ to the confirmation request.

7 RedBoot> fis list -l Checks whether the image has been success fully stored, whether it is the desired Release and Build, and whether it is valid.

Show 6 more labels / short text on this page
Step Command Purpose · Step Command Purpose · 1 optional · 2 optional · 3 optional · Bootloader 44
Page 45 of the Patton electronic 4110 user manual — Start-up with factory configuration
Page 45 · click to enlarge
Page 45

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

8 RedBoot> go Starts the application image that was down loaded into the volatile memory (RAM).

Note With the Bootloader, only the Ethernet interface 0/0 is available. The Boot loader applies the IP address, subnet mask, and default gateway that were last configured by the Bootloader itself or by another application (e.g. Smart Ware). If an application configured the Ethernet interface 0/0 to use DHCP, the Bootloader will also use DHCP to learn the interface configuration. It can receive and apply the IP address, subnet mask, default gateway, and default (TFTP) server (transmitted as basic DHCP information ‘Next server IP address’).

ExampleDownloading and storing a new application image (SmartWare)

RedBoot> ip -l 172.16.40.98/19 RedBoot> ip -g 172.16.32.1 RedBoot> ping -h 172.16.32.100 Network PING - from 172.16.40.98 to 172.16.32.100 PING - received 10 of 10 expected

RedBoot> load -r -v -h 172.16.32.100 -b 0x1800100 /Sn4xxx/image.bin Using default protocol (TFTP) - Raw file loaded 0x01800100-0x0199ca6b, 1689964 bytes, assumed entry at 0x01800100

RedBoot> fis delete -n 1 Delete image 1 - continue (y/n)? y ... Erase from 0x60030000-0x601cc974:

RedBoot> fis create Use address 0x01800100, size 1684402 ? - continue (y/n)? y ... Erase from 0x60030000-0x601cb3ba: Program from 0x00011eec-0x00011ef4 at 0x60030000: Program from 0x01800100-0x0199b4b2 at 0x60030008: Program from 0x00011eec-0x00011ef4 at 0x60030000: . Image successfully written to flash

RedBoot> fis list -l Id Address Length State Description Entry Load Addr Version 1 0x60030000 1693438 valid SmartWare R2.10 BUILD28015 0x01800100 0x01800100 V2.10

RedBoot> go Starting 'SmartWare R2.10 BUILD28015' at 0x01800100 via 0x01800100

Step Command Purpose · Bootloader 45

Page 46 of the Patton electronic 4110 user manual — Additional information
Page 46 · click to enlarge
Page 46

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

Load a new application image (SmartWare) via the serial link The Bootloader supports the ‘X-Modem’ and ‘Y-Modem’ protocols to download application images via the serial link of the console. Do the following to initiate the download:

1 RedBoot> load -r -v -m { xmodem | ymodem } -b base_address

Downloads an application image into the volatile memory (RAM) from where the SmartNode could directly execute it. ‘xmodem’ or ‘ymodem’: Specify the protocol to be used, X- Modem or Y-Modem base_address: memory location where to store the application image. Use the default address 0x1800100 Execute the above RedBoot command first, then start the trans fer from the terminal program with the command ‘Send file via X-Modem’ (or similar).

5 RedBoot> fis delete -n 1 Deletes the first application image. Reply with ‘y’ to the confirmation request.

6 RedBoot> fis create Stores the downloaded application image to the permanent memory (flash:). Reply with ‘y’ to the confirmation request.

7 RedBoot> fis list -l Checks whether the image has been successfully stored, whether it is the desired Release and Build, and whether it is valid.

8 RedBoot> go Starts the application image that was downloaded to the vola tile memory (RAM).

Additional information

For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the SmartNode Series SmartWare Software Configuration Guide available online at www.patton.com/ manuals.

Step Command Purpose · Additional information 46

Page 47 of the Patton electronic 4110 user manual — Chapter contents
Page 47 · click to enlarge
Page 47

Chapter 5 LEDs status and monitoring

Chapter contents

Status LEDs 48

Page 48 of the Patton electronic 4110 user manual — Status LEDs
Page 48 · click to enlarge
Page 48

SmartNode 4520 & 4110 Series User Manual 5 • LEDs status and monitoring

Status LEDs

This chapter describes SmartNode gateway router front panel LEDs. Figure 27 shows SmartNode 4520 Series LEDs, figure 28 on page 49 shows SmartNode 4110 Series LEDs. LED definitions are listed in table 9 on page 50.

Patton electronic 4110 — Status LEDs diagram (page 48)
Fig. 32 · Status LEDs

Figure 27. Examples of SN4520 Series front panels

Status LEDs 48

Page 49 of the Patton electronic 4110 user manual — Status LEDs
Page 49 · click to enlarge
Page 49

SmartNode 4520 & 4110 Series User Manual 5 • LEDs status and monitoring

Patton electronic 4110 — Status LEDs diagram (page 49)
Fig. 33 · Status LEDs

Figure 28. Examples of SN4110 Series front panels

Status LEDs 49

Page 50 of the Patton electronic 4110 user manual — Status LEDs
Page 50 · click to enlarge
Page 50

SmartNode 4520 & 4110 Series User Manual 5 • LEDs status and monitoring

Table 9. SmartNode LED Indications

Power When lit, indicates power is applied. Off indicates no power applied.

Run When lit, indicates normal operation. Flashes once per second during boot (startup).

VoIP Link When lit, indicates the gateway is registered on a gatekeeper, media gateway con troller, associated to a remote unit, or has an active VoIP connection. Off indicates the unit is not configured or registered and has no active VoIP connection. Flashing green indicates that the unit is attempting or has failed to associate/register

FXS (each port) Off indicates on-hook condition. Solid green when off-hook. Flashes to follow ring cadence.

FXO (each port) Off indicates on-hook condition. Solid green when off-hook. Flashes to follow ring cadence.

Ethernet (each port) • Link: Lit when Ethernet link is up.

  • 100M : On when 100-Mbps Ethernet is selected.
  • Activity : Flashes when data is received or transmitted from the unit to the LAN.

LED Description · Status LEDs 50

Page 51 of the Patton electronic 4110 user manual — Table of contents
Page 51 · click to enlarge
Page 51

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 52 of the Patton electronic 4110 user manual — Warranty Service and Returned Merchandise Authorizations (RMAs)
Page 52 · click to enlarge
Page 52

SmartNode 4520 & 4110 Series User Manual 6 • Contacting Patton for assistance

Introduction

This chapter contains the following information:

  • “Contact information” —describes how to contact Patton technical support for assistance.
  • “Warranty Service and Returned Merchandise Authorizations (RMAs)” —contains information about the RAS warranty and obtaining a return merchandise authorization (RMA).

Contact information

Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems:

  • Online support—available at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a>
  • E-mail support—e-mail sent to support@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a> will be answered within 1 business day
  • Telephone support—standard telephone support is available five days a week—from 8:00 am to 5:00 pm EST ( 1300 to 2200 UTC )—by calling +1 (301) 975-1007

Warranty Service and Returned Merchandise Authorizations (RMAs)

Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship ment. All of our products are backed by a comprehensive warranty program.

Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.

Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro phes may require replacement.

Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.

Introduction 52

Page 53 of the Patton electronic 4110 user manual — Return for credit policy
Page 53 · click to enlarge
Page 53

SmartNode 4520 & 4110 Series User Manual 6 • Contacting Patton for assistance

Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.

  • 30 to 60 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
  • Over 60 days: Products will be accepted for repairs only.

RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:

  • Completing a request on the RMA Request page in the Support section at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a>
  • By calling +1 (301) 975-1007 and speaking to a Technical Support Engineer
  • By sending an e-mail to returns@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a>

All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.

Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:

Patton Electronics Company RMA#xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA

Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.

Warranty Service and Returned Merchandise Authorizations (RMAs) 53

Page 54 of the Patton electronic 4110 user manual — Table of contents
Page 54 · click to enlarge
Page 54

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 55 of the Patton electronic 4110 user manual — Authorized European Representative
Page 55 · click to enlarge
Page 55

SmartNode 4520 & 4110 Series User Manual A • Compliance

Compliance

EMC Compliance• FCC Part 15, Class A
  • EN55022, Class A
  • EN55024
Safety Compliance• UL60950-1/CSA C22.2 No. 60950-1
  • IEC 60950-1
  • EN60950-1
  • AS/NZS 60950-1
PSTN Regulatory Compliance• FCC Part 68
  • CS-03
  • TBR 21
  • AS/ACIF S002
  • AS/ACIF S003

CE Declaration of Conformity

We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity.

The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.

Authorized European Representative

D R M Green

European Compliance Services Limited.

Oakdene House, Oak Road

Swindon, Wilts SN6 8TD, UK

Watchfield, · Compliance 55

Page 56 of the Patton electronic 4110 user manual — Industry Canada Notice (FXO Ports)
Page 56 · click to enlarge
Page 56

SmartNode 4520 & 4110 Series User Manual A • Compliance

Radio and TV Interference (FCC Part 15)

This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reason able protection from such interference in a commercial installation. However, there is no guarantee that inter ference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equip ment and receiver are on different branches).

FCC Part 68 (ACTA) Statement (FXO Ports)

This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.

The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.

If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.

If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you dis connect the equipment until the problem is resolved.

Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.

Industry Canada Notice (FXO Ports)

This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that reg istration was performed based on a Declaration of Conformity indicating that Industry Canada technical spec ifications were met. It does not imply that Industry Canada approved the equipment.

This Declaration of Conformity means that the equipment meets certain telecommunications network protec tive, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be con nected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The

Radio and TV Interference (FCC Part 15) 56

Page 57 of the Patton electronic 4110 user manual — Radio and TV Interference (FCC Part 15)
Page 57 · click to enlarge
Page 57

SmartNode 4520 & 4110 Series User Manual A • Compliance

customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment mal functions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.

Industry Canada Notice (FXO Ports) 57

Page 58 of the Patton electronic 4110 user manual — Table of contents
Page 58 · click to enlarge
Page 58

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 59 of the Patton electronic 4110 user manual — DSP 59
Page 59 · click to enlarge
Page 59

SmartNode 4520 & 4110 Series User Manual B • Specifications

DSP

One or two 4-channel DSPs

Voice connectivity

Short haul loop 1.1 km @3REN

EuroPOTS (ETSI EG201 188)

Programmable AC impedance, feeding, and ring voltage; On-Hook Voltage 29VDC

Caller-ID Type-1/2 FSK and ITU V.23/Bell 202 generation

Connectivity

2 10/100 Full Duplex/Autosensing Ethernet RJ-45

Voice processing (signalling dependent)

Voice codes:

  • G.711 A-Law/ -Law (64 kbps)
  • G.726 (ADPCM 40, 32, 24, 16 kpbs)
  • G.723.1 (5.3 or 6.3 kbps)
  • G.729ab (8 kbps)
  • Transparent pass through

G.168 echo cancellation

8 parallel voice connections

DTMF detection and generation

Carrier tone detection and generation

Silence suppression and comfort noise

Configurable tones (dial, ringing, busy)

Configurable transmit packet length

RTP/RTCP (RFC 1889)

Fax and modem support

G.711 transparent FAX

Fax over IP (FoIP)

T.38 Fax relay (9.6 k, 14.4 k)

DSP 59

2-wire Loopstart, RJ-11/12 · Configurable dejitter buffer

Page 60 of the Patton electronic 4110 user manual — IP services
Page 60 · click to enlarge
Page 60

SmartNode 4520 & 4110 Series User Manual B • Specifications

Voice signalling

H.323v4

  • RAS, H.225, H.245
  • Fast-connect, early H.245
  • Gatekeeper autodiscovery
  • Alias registration
  • Overlap sending
  • Empty capability set (call transfer, hold)
  • H.323v1 call transfer, hold

ISDN over IP (ISoIP)

  • H.323 GW and GK compatible
  • H.323 Annex M3
  • ISDN/Q-SIG feature tunneling
  • ISDN speech, audio and data (Fax Gr 4, UDI 64, RDI 64)

Voice routing—session router

Local switching; Interface huntgroups

  • Interface
  • Calling/called party number
  • Time of day, day of week, date
  • ISDN bearer capability
  • Replace numbers; Add/remove digits
  • Multiple remote gateways; PLAR

IP services

IPv4 router; RIPv1, v2 (RFC 1058 and 2453)

ICMP redirect (RFC 792); Packet fragmentation

DiffServe/ToS set or queue per header bits

Pocket Policing discards excess traffic

802.1p VLAN tagging

Show 4 more labels / short text on this page
Routing Criteria · Number manipulation functions · Programmable static routes · Voice signalling 60
Page 61 of the Patton electronic 4110 user manual — 12W
Page 61 · click to enlarge
Page 61

SmartNode 4520 & 4110 Series User Manual B • Specifications

IPSEC AH & ESP Modes

Manual Key; IKE optional

Management

Industry standard CLI with local console (RJ-45, RS-232, 9600 bps, 8, N, 1), and remote Telnet access

TFTP configuration & firmware loading

SNMP v1 agent (MIB II and private MIB)

Built-in diagnostic tools (trace, debug)

Java™ Applet; HPOV Integration with NNM

Operating environment

Operating temperature 32–104°F (0–40°C)

Operating humidity 5–80% (non condensing)

System

CPU Motorola MPC859 operating at 50 MHz

Memory:

  • 32 Mbytes SDRAM
  • 4 Mbytes Flash

Dimensions

7.3W x 1.6H x 6.1D in. (18.5H x 4.1W x 15.5D cm)

Weight and power dissipation

See table 10.

Table 10. SmartNode weight and maximum power specifications

SmartNode model Weight Maximum power dissipation

SN4112/SN4522 30.5 oz/500 g 6W

SN4114/SN4524 30.5 oz/500 g 8W

SN4116/SN4526 24.4 oz/400 ga

12W

SN4118/SN4528 24.4 oz/400 ga 15W

a. Excluding external power supply

AES/DES/3DES Encryption · Management 61

Page 62 of the Patton electronic 4110 user manual — Identification of the SmartNode devices via SNMP
Page 62 · click to enlarge
Page 62

SmartNode 4520 & 4110 Series User Manual B • Specifications

Power supply

The terminal block header to which the wires are secured pro vides the disconnect for the SmartNode. Take proper measures to ensure that it is not permanently fastened to the receptacle mounted on the chassis.

CAUTION

AC version Internal power supply 100–240 VAC, 50/60 Hz, 200 mA

DC version 12 VDC, 1.25 A

Identification of the SmartNode devices via SNMP

All SmartNode devices have assigned sysObjectID (.iso.org.dod.internet.mgmt.mib-2.system.sysObjectID) numbers (see table 11).

Table 11. SmartNode Models and their Unique sysObjectID

SN4112-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.5 1.3.6.1.4.1.1768.2.4.5.5

SN4112-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.19 1.3.6.1.4.1.1768.2.4.5.19

SN4114-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.6 1.3.6.1.4.1.1768.2.4.5.6

SN4114-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.20 1.3.6.1.4.1.1768.2.4.5.20

SN4114-2JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.12 1.3.6.1.4.1.1768.2.4.5.12

SN4116-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.7 1.3.6.1.4.1.1768.2.4.5.7

SN4116-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.21 1.3.6.1.4.1.1768.2.4.5.21

SN4116-4JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.13 1.3.6.1.4.1.1768.2.4.5.13

SN4118-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.8 1.3.6.1.4.1.1768.2.4.5.8

SN4118-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.22 1.3.6.1.4.1.1768.2.4.5.22

SmartNode Model SysObjectID · Power supply 62

Page 63 of the Patton electronic 4110 user manual — IMPORTANT
Page 63 · click to enlarge
Page 63

SmartNode 4520 & 4110 Series User Manual B • Specifications

Table 11. SmartNode Models and their Unique sysObjectID (Continued)

SN4118-4JS4JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.14 1.3.6.1.4.1.1768.2.4.5.14

SN4524-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.1 1.3.6.1.4.1.1768.2.4.5.1

SN4526-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.3 1.3.6.1.4.1.1768.2.4.5.3

SN4528-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.4 1.3.6.1.4.1.1768.2.4.5.4

SN4524-2JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.9 1.3.6.1.4.1.1768.2.4.5.9

SN4526-4JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.10 1.3.6.1.4.1.1768.2.4.5.10

SN4528--4JS4JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.11 1.3.6.1.4.1.1768.2.4.5.11

SN4522-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.15 1.3.6.1.4.1.1768.2.4.5.15

SN4524-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.16 1.3.6.1.4.1.1768.2.4.5.16

SN4526-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.17 1.3.6.1.4.1.1768.2.4.5.17

SN4528-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.18 1.3.6.1.4.1.1768.2.4.5.18

According to table 11, an SNMP get request to .iso.org.dod.internet.mgmt.mib-2.system.sysObjectID of a Smart Node 4112-JS device reads out a numeric OID of 1.3.6.1.4.1.1768.2.4.5.5, which represents a SmartNode 4112 device. The mapping of the sysObjectID to each of the SmartNode model is realized with the Smart Node product identification MIB.

The SNMP agent running in SmartWare is SNMP version 1 (SNMPv1) compliant. SNMP version 2 (SNMPv2) and SNMP version 3 (SNMPv3) are not currently supported.

IMPORTANT

Identification of the SmartNode devices via SNMP 63

SmartNode Model SysObjectID

Page 64 of the Patton electronic 4110 user manual — Table of contents
Page 64 · click to enlarge
Page 64

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 65 of the Patton electronic 4110 user manual — Serial console
Page 65 · click to enlarge
Page 65

SmartNode 4520 & 4110 Series User Manual C • Cabling

Introduction

This section provides information on the cables used to connect the SmartNode and the interface cards to the existing network infrastructure and to third party products.

Patton electronic 4110 — Introduction diagram (page 65)
Fig. 34 · Introduction

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Serial console

The SmartNode can be connected to a serial terminal over its serial console port, as depicted in figure 29.

Patton electronic 4110 — Serial console diagram (page 65)
Fig. 35 · Serial console

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524

Figure 29. Connecting a serial terminal

Introduction 65

Page 66 of the Patton electronic 4110 user manual — Ethernet 10Base-T and 100Base-T
Page 66 · click to enlarge
Page 66

SmartNode 4520 & 4110 Series User Manual C • Cabling

Ethernet 10Base-T and 100Base-T

Patton electronic 4110 — Ethernet 10Base-T and 100Base-T diagram (page 66)
Fig. 36 · Ethernet 10Base-T and 100Base-T

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Ethernet devices (10Base-T/100Base-T) are connected to the SmartNode over a cable with RJ-45 plugs. Use a cross-over cable to a host, or a straight cable to a hub. See figure 30 (host) and figure 31 on page 67 (hub) for the different connections.

Patton electronic 4110 — Ethernet 10Base-T and 100Base-T diagram (page 66)
Fig. 37 · Ethernet 10Base-T and 100Base-T

Figure 30. Ethernet cross-over

Ethernet 10Base-T and 100Base-T 66

Page 67 of the Patton electronic 4110 user manual — Ethernet 10Base-T and 100Base-T
Page 67 · click to enlarge
Page 67
Patton electronic 4110 — Ethernet 10Base-T and 100Base-T diagram (page 67)
Fig. 38 · Ethernet 10Base-T and 100Base-T

SmartNode 4520 & 4110 Series User Manual C • Cabling

Figure 31. Ethernet straight-through

Ethernet 10Base-T and 100Base-T 67

Page 68 of the Patton electronic 4110 user manual — Analog FXS
Page 68 · click to enlarge
Page 68

SmartNode 4520 & 4110 Series User Manual C • Cabling

Analog FXS

Patton electronic 4110 — Analog FXS diagram (page 68)
Fig. 39 · Analog FXS

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Applicable to SmartNodes equipped with FXS ports. The FXS ports are connected to analog terminals (phones, fax machines, answering machines) via cables terminated with RJ-11 connectors (see section “FXS port” on page 72 for details on port pinouts).

Patton electronic 4110 — Analog FXS diagram (page 68)
Fig. 40 · Analog FXS

Figure 32. Connecting an FXS device

Analog FXS 68

Page 69 of the Patton electronic 4110 user manual — Analog FXO
Page 69 · click to enlarge
Page 69

SmartNode 4520 & 4110 Series User Manual C • Cabling

Analog FXO

Patton electronic 4110 — Analog FXO diagram (page 69)
Fig. 41 · Analog FXO

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION

Applicable to SmartNodes equiped with FXO ports. The FXO ports are connected to analog phone lines via cables terminated with RJ-11 connectors (see section “FXO port” on page 72 for details on port pinouts).

Patton electronic 4110 — Analog FXO diagram (page 69)
Fig. 42 · Analog FXO

Figure 33. Connecting to an FXO line socket

Analog FXO 69

Page 70 of the Patton electronic 4110 user manual — Table of contents
Page 70 · click to enlarge
Page 70

Table of contents

Table of Contentsp.3About this guidep.6Audiencep.6Structurep.6Precautionsp.7Safety when working with electricityp.7Preventing electrostatic discharge damagep.8General observationsp.9Typographical conventions used in this documentp.9General conventionsp.9Chapter 1 General informationp.10SmartNode Series VoIP routers overviewp.11SmartNode 4520 Series routerp.12Ports descriptionsp.14Reset button behaviorp.14SmartNode 4110 Series routerp.16Ports descriptionsp.18Reset button behaviorp.18Chapter 2 Applications overviewp.20Introductionp.21Applications for SmartNode 4110 Seriesp.21SIP and H.323 terminal and PSTN gatewaysp.21Application-Analog line extension over IPp.22Application-ITSP dial-in accessp.22Application-Private line automatic ringdown (PLAR)p.23Application-Enterprise campus BRI to FXS telephony extensionp.23Application-PBX toll bypass gatewayp.24Applications for SmartNode 4520 Seriesp.24Application-SOHO off-premise extensionp.25Application-Single-phone PSTN and VoIP accessp.26Chapter 3 Hardware installationp.27Planning the installationp.28Installation checklistp.29Site logp.30Network informationp.30Network Diagramp.30IP related informationp.30Software toolsp.30Power sourcep.30Location and mounting requirementsp.31Installing the gateway routerp.31Mounting the gateway routerp.31Connecting cablesp.31Installing an interface cable on the router’s FXS and FXO interface portsp.32Installing the Ethernet cablep.34Connecting to external power sourcep.36Chapter 4 Getting started with the SmartNodep.38Introductionp.391. Configure IP addressp.40Power connection and default configurationp.40Connect with the serial interfacep.40Loginp.41Changing the IP addressp.412. Connect the SmartNode to the networkp.423. Load configurationp.42Bootloaderp.43Start Bootloaderp.43Start-up with factory configurationp.44Load a new application image (SmartWare) via TFTPp.44Load a new application image (SmartWare) via the serial linkp.46Additional informationp.46Chapter 5 LEDs status and monitoringp.47Status LEDsp.48Chapter 6 Contacting Patton for assistancep.51Introductionp.52Contact informationp.52Warranty Service and Returned Merchandise Authorizations (RMAs)p.52Warranty coveragep.52Out-of-warranty servicep.52Returns for creditp.52Return for credit policyp.53RMA numbersp.53Shipping instructionsp.53Appendix A Compliancep.54Compliancep.55EMC Compliance:p.55Safety Compliance:p.55PSTN Regulatory Compliance:p.55CE Declaration of Conformityp.55Authorized European Representativep.55Radio and TV Interference (FCC Part 15)p.56FCC Part 68 (ACTA) Statement (FXO Ports)p.56Industry Canada Notice (FXO Ports)p.56Appendix B Specificationsp.58DSPp.59Voice connectivityp.59Connectivityp.59Voice processing (signalling dependent)p.59Fax and modem supportp.59Voice signallingp.60Voice routing-session routerp.60IP servicesp.60Managementp.61Operating environmentp.61Operating temperaturep.61Operating humidityp.61Systemp.61Dimensionsp.61Weight and power dissipationp.61Power supplyp.62AC versionp.62DC versionp.62Identification of the SmartNode devices via SNMPp.62Appendix C Cablingp.64Introductionp.65Serial consolep.65Ethernet 10Base-T and 100Base-Tp.66Analog FXSp.68Analog FXOp.69Appendix D Port pin-outsp.70Introductionp.71Console portp.71Ethernet 10Base-T and 100Base-T portp.71FXS portp.72FXO portp.72Appendix E SmartNode 4110 Series factory configurationp.73Introductionp.74Appendix F SmartNode 4520 Series factory configurationp.75Introductionp.76Appendix G Installation checklistp.77Introductionp.78
Page 71 of the Patton electronic 4110 user manual — 1 TX+
Page 71 · click to enlarge
Page 71

SmartNode 4520 & 4110 Series User Manual D • Port pin-outs

Introduction

This section provides pin-out information for the ports of the SmartNode.

Console port

Configuration settings9600 bps, 8 bits, no parity, no flow control

Figure 34. EIA-561 (RJ-45 8-pin) port

Ethernet 10Base-T and 100Base-T port

Table 12. RJ-45 socket

1 TX+

2 TX-

3 RX+

6 RX-

Pin Signal · Introduction 71

Page 72 of the Patton electronic 4110 user manual — FXO port
Page 72 · click to enlarge
Page 72

SmartNode 4520 & 4110 Series User Manual D • Port pin-outs

FXS port

The FXS ports use an RJ-11 connector with 6 positions. The midle two positions 3 and 4 are used according to table 13.

Table 13. RJ-11 socket

FXO port

The FXO ports use an RJ-11 connector with 6 positions. The midle two positions 3 and 4 are used according to table 14.

Table 14. RJ-11 socket

Show 7 more labels / short text on this page
Pin Signal · 3 Ring (-) · 4 Tip (+) · Pin Signal · 3 Ring (-) · 4 Tip (+) · FXS port 72
Page 73 of the Patton electronic 4110 user manual — Chapter contents
Page 73 · click to enlarge
Page 73

Appendix E SmartNode 4110 Series factory

configuration

Chapter contents

Introduction 74

Page 74 of the Patton electronic 4110 user manual — Introduction
Page 74 · click to enlarge
Page 74

SmartNode 4520 & 4110 Series User Manual E • SmartNode 4110 Series factory configuration

Introduction

The factory configuration settings for SmartNode 4110 Series devices are as follows:

# 4110 Series # # Factory configuration file #

sntp-client sntp-client server primary 129.132.2.21 port 123 version 4

system ic voice 0 low-bitrate-codec g729

interface eth0 ipaddress dhcp tcp adjust-mss rx mtu tcp adjust-mss tx mtu

port ethernet 0 0 medium auto encapsulation ip bind interface eth0 router no shutdown

context ip router · Introduction 74

Page 75 of the Patton electronic 4110 user manual — Chapter contents
Page 75 · click to enlarge
Page 75

Appendix F SmartNode 4520 Series factory

configuration

Chapter contents

Introduction 76

Page 76 of the Patton electronic 4110 user manual — Introduction
Page 76 · click to enlarge
Page 76

SmartNode 4520 & 4110 Series User Manual F • SmartNode 4520 Series factory configuration

Introduction

The factory configuration settings for SmartNode 4520 Series devices are as follows:

# 4520 Series # # Factory configuration file #

dns-relay sntp-client sntp-client server primary 129.132.2.21 port 123 version 4

ic voice 0 low-bitrate-codec g729 profile napt NAPT

profile dhcp-server DHCP network 192.168.1.0 255.255.255.0 include 1 192.168.1.10 192.168.1.99 lease 2 hours default-router 1 192.168.1.1 domain-name-server 1 192.168.1.1

interface eth0 ipaddress dhcp use profile napt NAPT tcp adjust-mss rx mtu tcp adjust-mss tx mtu

interface eth1 ipaddress 192.168.1.1 255.255.255.0 tcp adjust-mss rx mtu tcp adjust-mss tx mtu

context ip router dhcp-server use DHCP

port ethernet 0 0 medium auto encapsulation ip bind interface eth0 router no shutdown

port ethernet 0 1 medium auto encapsulation ip bind interface eth1 router no shutdown

system · context ip router · Introduction 76

Page 77 of the Patton electronic 4110 user manual — Chapter contents
Page 77 · click to enlarge
Page 77

Appendix G Installation checklist

Chapter contents

Introduction 78

Page 78 of the Patton electronic 4110 user manual — Introduction
Page 78 · click to enlarge
Page 78

SmartNode 4520 & 4110 Series User Manual G • Installation checklist

Introduction

This appendix lists the tasks for installing a SmartNode 4520 or 4110 Series router (see table 15) . Make a copy of this checklist and mark the entries as you complete each task. For each SmartNode 4520 or 4110 Series router, include a copy of the completed checklist in your site log.

Table 15. Installation checklist

Task Verified by Date

Network information available & recorded in site log

Site power voltages verified

Installation site pre-power check completed

All printed documents available

SmartWare release & build number verified

Rack, desktop, or wall mounting of chassis completed

Initial electrical connections established

ASCII terminal attached to console port

Cable length limits verified

Show 6 more labels / short text on this page
Environmental specifications verified · Required tools available · Additional equipment available · Initial configuration performed · Initial operation verified · Introduction 78
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 4110

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 4110

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 4110 manual PDF

78 pages·3.3 MB·Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…