User Manual


Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Trademark Statement The terms SmartWare and SmartView are trademarks of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.
Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec tronics assumes no liability for errors that may appear in this document.
Warranty Information The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.
Patton Electronics warrants all SmartNode router components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.


This guide describes the SmartNode 4110 and 4520 Series hardware, installation and basic configuration. For detailed software configuration information refer to the SmartWare Software Configuration Guide and the avail able Configuration Notes.
This guide is intended for the following users:
This guide contains the following chapters and appendices:

SmartNode 4520 & 4110 Series User Manual About this guide
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and CAUTION heading indicate a potential haz ard. Strictly follow the instructions to avoid property damage.
Safety when working with electricity
The SmartNode contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service per sonnel.
Mains Voltage: Do not open the case when the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected. The mains outlet that is utilized to power the SmartNode router shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker.
For AC powered units, ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.

SmartNode 4520 & 4110 Series User Manual About this guide
For units with an external power adapter, the adapter shall be a listed Lim ited Power Source.
Hazardous network voltages are present in WAN ports regardless of whether power to the SmartNode is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the SmartNode first.
Before opening the chassis, disconnect the telephone network cables to avoid contact with telephone line voltages. When detaching the cables, detach the end away from the SmartNode first.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
Preventing electrostatic discharge damage When starting to install interface cards place the interface card on its shielded plastic bag if you lay it on your bench.
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermit tent failures. Do the following to prevent ESD:

SmartNode 4520 & 4110 Series User Manual About this guide
This section describes the typographical conventions and terms used in this guide.
General conventions The procedures described in this manual use the following text conventions:
Table 1. General conventions


SmartNode 4520 & 4110 Series User Manual 1 • General information
The SmartNode 4520 and 4110 Series VoIP Gateway Routers (see figure 1) combine IP routing, VPN/Secu rity, and Quality of Service for up to 8 transparent voice and FAX calls over any IP or PSTN network. Leverage low-cost IP services with packet-voice for complete branch office voice and data connectivity.

Figure 1. SmartNode Router (SmartNode 4524 shown)
The SmartNode 4520 Series Gateway Routers, equipped with two 10/100Base-T Ethernet ports provide; voice over IP (VoIP) and Internet telephony plus Internet access routing, VPN and firewall functions, and extensive Quality of Service (QoS) functions.
The SmartNode 4110 Series Media Gateways, equipped with a single 10/100Base-T Ethernet port that pro vide VoIP and Internet telephony.
The SmartNode VoIP Gateways and Gateway-Routers perform the following major functions:
Section “SmartNode 4520 Series router” on page 12 provides more information on the SmartNode 4520 Series. Section “SmartNode 4110 Series router” on page 16 describes the SmartNode 4110 Series.
SmartNode Series VoIP routers overview 11

SmartNode 4520 & 4110 Series User Manual 1 • General information
SmartNode 4520 Series router The SmartNode 4520 Series are compact VoIP Gateway Routers that support two to eight VoIP calls and var ious combinations of FXS and FXO ports (see figure 2).

Figure 2. Examples of SN4520 Series rear panels
The following base models (each equipped with two 10/100Base-T Ethernet ports) are available:
SmartNode Series VoIP routers overview 12

SmartNode 4520 & 4110 Series User Manual 1 • General information
The port combinations are indicated in the extension of the model code. The products the following model code conventions apply:
For example, the model code SN4526/4JS2JO/EUI describes a SmartNode configured as follows:

Figure 3. SmartNode 4520 Series power input connectors
SmartNode Series VoIP routers overview 13

SmartNode 4520 & 4110 Series User Manual 1 • General information
Ports descriptions The SmartNode 4520 Series rear panel ports are described in table 2.
Table 2. Rear panel ports
Rear panel RJ-45 connectors (see figure 16 on page 32) that connect the router to an
Ethernet device (e.g., a cable or DSL modem, LAN hub or switch).
Analog voice port, FXS
Rear panel FXS RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that
connect the router with an analog terminal (a telephone, for example) FXO port. EuroPOTS support (ETSI EG201 188). FXS on-hook voltage is 48V for each FXS port.
Analog voice port, FXO
Rear panel FXO RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that
connect the router with an analog line (FXS port). EuroPOTS support (ETSI EG201 188).
Power Rear panel The gateway is available in a DC or AC power input version (see
figure 3), labeled as follows:
Console Front panel Used for service and maintenance, the Console port (see figure 4 on page 15),
an RS-232 RJ-45 connector, connects the router to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal).
Reset button behavior For those SmartNode devices that have a Reset button on the rear panel, its behavior is as follows:
SmartNode Series VoIP routers overview 14
Port Location Description · 10/100 Ethernet

SmartNode 4520 & 4110 Series User Manual 1 • General information

Figure 4. SmartNode 4520 Series front panels
SmartNode Series VoIP routers overview 15

SmartNode 4520 & 4110 Series User Manual 1 • General information
SmartNode 4110 Series router The SmartNode 4110 Series are compact VoIP Gateways that support two to eight VoIP calls and various combinations of FXS and FXO ports (see figure 5).

Figure 5. Examples of SN4110 Series rear panels
The following base models (each equipped with one 10/100Base-T Ethernet port) are available:
SmartNode Series VoIP routers overview 16

SmartNode 4520 & 4110 Series User Manual 1 • General information
The port combinations are indicated in the extension of the model code. The products the following model code conventions apply:
For example, the model code SN4116/4JS2JO/EUI describes a SmartNode configured as follows:

Figure 6. SmartNode 4110 Series power input connectors
SmartNode Series VoIP routers overview 17

SmartNode 4520 & 4110 Series User Manual 1 • General information
Ports descriptions The SmartNode 4110 Series rear panel ports are described in table 3.
Table 3. Rear panel ports
Rear panel RJ-45 connector (see figure 5 on page 16) that connects the router to an
Ethernet device (a cable or DSL modem, LAN hub or switch, for example).
Analog voice port, FXS
Rear panel FXS RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that
connect the router with an analog terminal (a telephone, for example) FXO port. EuroPOTS support (ETSI EG201 188).
Analog voice port, FXO
Rear panel FXO RJ-11(6 position, 4 wire) connectors (see figure 16 on page 32) that
connect the router with an analog line (FXS port). EuroPOTS support (ETSI EG201 188).
Power Rear panel The gateway is available in a DC or AC power input version (see
figure 6), labeled as follows:
Console Front panel Used for service and maintenance, the Console port (see figure 7 on page 19),
an RS-232 RJ-45 connector, connects the router to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal).
Reset button behavior For those SmartNode devices that have a Reset button on the rear panel, its behavior is as follows:
SmartNode Series VoIP routers overview 18
Port Location Description · 10/100 Ethernet

SmartNode 4520 & 4110 Series User Manual 1 • General information

Figure 7. SmartNode 4110 Series front panels
SmartNode Series VoIP routers overview 19


SmartNode 4520 & 4110 Series User Manual 2 • Applications overview
Patton’s SmartNode Media Gateway Routers deliver the features you need for advanced multiservice voice and data network applications. They combine high quality voice-over-IP with powerful quality of service routing functions to build professional and reliable VoIP networks. This chapter describes typical applications for which the SmartNodes are uniquely suited.
The SmartNode 4110 Series device, equipped with a single Ethernet port, provides gateway and over-IP line extension services.
SIP and H.323 terminal and PSTN gateways All models provide voice-over-IP and FAX-over-IP services for integration into a VoIP network running the SIP or H.323 protocol (see figure 8). The SmartNode 4110 Series supports automatic registration to a Gatekeeper or SIP server to provide analog extension services or PSTN breakout connectivity.

Figure 8. PSTN and Terminal gateways
Introduction 21

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview
Application—Analog line extension over IP A virtual analog line can be created using an FXO and FXS model (see figure 9). The complete signaling and media (voice, fax, or modem) of the analog phone line is extended over IP. This enables a PBX analog exten sion line to be extended to a home office or satellite office. The analog line extension relays DTMF, hook-flash and CLI to provide full PBX feature access over the IP network (checking voice mail or joining a calling group, for example).

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
Figure 9. Analog line extension
Application—ITSP dial-in access An ITSP can use the SmartNode FXO gateways as dial-in access points to his Internet telephony services (see figure 10). A user calls a local number, the FXO SmartNode picks up the call and uses a second dial-tone to dial the remote number. The system can be enhanced with a central call control server providing IVR announcements, PIN checking, and accounting for the calls.

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
Figure 10. ITSP dial-in access
Applications for SmartNode 4110 Series 22

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview
Application—Private line automatic ringdown (PLAR) A private hot-line can be created by using two FXS models back-to-back (see figure 11). These can be found in use as courtesy phones at ATM’s, information kiosks, and emergency assistance pedestals. In this applica tion, when one handset is picked-up, the remote handset immediately begins ringing. When the remote handset is picked-up, the speech path is completed. The end-to-end link supports voice, fax Gr.3 (2.4–14.4 kbps) with T.38 or fax- and modem bypass using a G.711 codec.

Figure 11. FXS to FXS Hotline
Application—Enterprise campus BRI to FXS telephony extension In combination with the Patton SmartNode 1000 and 2000 Series models the FXS gateways provide ISDN BRI to FXS extensions over IP (see figure 12).

Figure 12. BRI to FXS extension
Applications for SmartNode 4110 Series 23

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview
Application—PBX toll bypass gateway The gateways can be used to provide toll bypass over an IP WAN (see figure 13). The call routing in this case is provided by the PBX systems. A call routed to the FXS gateway can be relayed on a port-to-port basis or depending on the dialed-number to the remote gateway.

Figure 13. Toll bypass
SmartNode 4520 Series devices have dual 10/100Base-T Ethernet ports. The two Ethernet ports provide full featured IP routing between LAN and WAN plus Ethernet and IP layer QoS services. Voice prioritization and traffic management avoid network congestion and provide optimal voice quality. With these additional fea tures the SmartNode 4520 series can add Internet access and data networking to any of the SmartNode 4110 Series applications described previously. The following sections show some typical combined voice- data applications.
Applications for SmartNode 4520 Series 24

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview
Application—SOHO off-premise extension For a SOHO/telecommuter, the SmartNode 4520 Series router can provide an off-premise extension to the corporate network (see figure 14). Along with the analog line extension features, the SmartNode provides Internet access and VPN connectivity to the main office. In this configuration, the remote user will appear to be local and can take advantage of services available to local telephony and LAN users (such as file-server access, station-to-station dialing, outside trunk access, and voice mail). Additionally, the home user can take advantage of corporate dialing rates.

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
Figure 14. Home office networking
Applications for SmartNode 4520 Series 25

SmartNode 4520 & 4110 Series User Manual 2 • Applications overview
Application—Single-phone PSTN and VoIP access The SmartNode 4520 Series with a combination of FXS and FXO ports can be used to make and receive calls via PSTN and Internet calling services over the same telephone handset (see figure 15). Using individually con figurable routing tables, an outbound call can be directed to the local PSTN connection or to an Internet tele phony service provider (ISTP). Inbound calls from the Internet and the PSTN can ring the same phone.

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
Figure 15. Single-phone access
Applications for SmartNode 4520 Series 26


SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Before you start the actual installation, it is strongly recommended that you gather all the information needed to install and setup the device. See table 4 for an example of what pre-installment checks you might need to carry out. Having carried out the pre-installation checks enables you to install and set up your gateway router into an existing infrastructure with confidence.
The mains outlet that is utilized to power the equipment must be within 1 foot (3 meters) of the device and shall be easily accessible. CAUTION
Before installing the gateway router device, the following tasks should be completed:
When you finish preparing for gateway router installation, go to section “Installing the gateway router” on page 31 to install the device.
Planning the installation 28

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Installation checklist The installation checklist (see table 4) lists the tasks for installing a SmartNode 4520 or 4110 Series router. Make a copy of this checklist and mark the entries as you complete each task. For each SmartNode 4520 or 4110 Series router, include a copy of the completed checklist in your site log.
Table 4. Installation checklist
Task Verified by Date
Network information available & recorded in site log
Site power voltages verified
Installation site pre-power check completed
All printed documents available
SmartWare release & build number verified
Rack, desktop, or wall mounting of chassis completed
Initial electrical connections established
ASCII terminal attached to console port
Cable length limits verified
Planning the installation 29

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Site log Patton recommends that you maintain a site log to record all actions relevant to the system, if you do not already keep such a log. Site log entries should include information such as listed in table 5.
Table 5. Sample site log entries
Installation Make a copy of the installation checklist and insert it into the site log
Upgrades and maintenance Use the site log to record ongoing maintenance and expansion history
Configuration changes Record all changes and the reasons for them
Maintenance Schedules, requirements, and procedures performed
Comments Notes, and problems
Software Changes and updates to SmartWare software
Network information Network connection considerations that you should take into account for planning are provided for several types of network interfaces are described in the following sections.
Network Diagram Draw a network overview diagram that displays all neighboring IP nodes, connected elements and telephony components.
IP related information Before you can set up the basic IP connectivity for your SmartNode 4000 series you should have the following information:
Software tools You will need a PC (or equivalent) with a VT-100 emulation program (e.g. HyperTerminal) to configure the software on your SmartNode router.
Power source If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery with large motors nearby, have a qualified professional test the power. Install a power conditioner if necessary.
Planning the installation 30
Entry Description

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Location and mounting requirements The SmartNode router is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables. Allow sufficient space at the rear of the chassis for cable connections. Additionally, you should consider the need to access the unit for future upgrades and maintenance.
When you finish installing the SmartNode, go to chapter 4, “Getting started with the SmartNode” on page 38.
Mounting the gateway router Place the router on a desktop or similar sturdy, flat surface that offers easy access to the cables. The router should be installed in a dry environment with sufficient space to allow air circulation for cooling.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.
Installing router cables takes place in the following order:
Installing the gateway router 31

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Installing an interface cable on the router’s FXS and FXO interface ports The gateway comes with at least two FXS or FXO analog ports—or a combination of FXS and FXO ports—(see figure 16) located on the back of the router. The FXS interfaces are connected to analog devices via cables (see figure 17) terminated with RJ-11 connectors (see figure 19 and table 6 on page 33 for pin-out information). The FXO interface connects the router with analog lines via cables (see figure 18 on page 33) terminated with RJ-11 connectors (see figure 19 and table 6 on page 33 for pin-out information).

Figure 16. Rear view showing location of Ethernet and FXS connectors (SmartNode 4520 shown)
Figure 17. Analog FXS connection
Installing the gateway router 32


SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Figure 18. Analog FXO connection

Figure 19. RJ-11 pinout diagram
Table 6. RJ-11 socket
Installing the gateway router 33
Pin Signal · 3 Ring (-) · 4 Tip (+)

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Installing the Ethernet cable The SmartNode 4520 Series has automatic MDX (auto-cross-over) detection and configuration on the Ether net ports. Any of the two ports can be connected to a host or hub/switch with a straight-through wired cable (see figure 20 on page 34). Ethernet devices (10Base-T or 100Base-T) are connected to the SmartNode’s Ethernet ports (see table 7 for port pin-out listing) via a cable terminated with RJ-45 plugs. Because the Smart Node 4110 Series does not have the MDX feature, a cross-over cable is required when connecting SmartNode 4110 Series devices to a host (see figure 21 on page 35).
Table 7. Ethernet 10/100Base-T (RJ-45) port pin-outs (SmartNode 4110 Series)
2 TX-
3 RX+
6 RX-

Figure 20. Connecting a SmartNode 4110 Series device to a hub
Installing the gateway router 34
Pin Signal

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

Figure 21. Connecting to a host (cross-over cable required for SmartNode 4110 Series only)
Installing the gateway router 35

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation
Connecting to external power source

The terminal block header to which the wires are secured pro vides the disconnect for the SmartNode. Take proper measures to ensure that it is not permanently fastened to the receptacle mounted on the chassis. CAUTION
The router comes with an internal or external power supply. This section describes installing the power cord into the router. Do the following:

Figure 22. Power connector location on rear panel
Installing the gateway router 36

SmartNode 4520 & 4110 Series User Manual 3 • Hardware installation

The router power supply automatically adjusts to accept an input voltage from 100 to 240 VAC (50/60 Hz).
Verify that the proper voltage is present before plugging the power cord into the receptacle. Failure to do so could result in equipment damage.

Figure 23. Router front panel LEDs and Console port locations (SmartNode 4524 shown)
Congratulations, you have finished installing the SmartNode Gateway Router! Now go to chapter 4, “Getting started with the SmartNode” on page 38.
Installing the gateway router 37


SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode
This chapter leads you through the basic steps to set up a new SmartNode and to download a configuration.
Patton SmartNodes can be used for a wide variety of IP-based network applications. To support and ease the configuration of the SmartNodes configuration, templates for the most important applications are available on the Patton server at www.patton.com/voip
The main steps for setting up a new SmartNode (as of release 2.00 or 2.10) are shown in figure 24.

Figure 24. Steps for setting up a new SmartNode
Introduction 39

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability.
Power connection and default configuration First the SmartNode must be connected to the mains power supply with the power cable. Wait until the 'Run' LED stops blinking and lights constantly. Now the SmartNode is ready.
The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 8.
Table 8. Factory default IP address and network mask configuration

Both Ethernet interfaces are activated upon power-up.
If these addresses match with those of your network, go to section “2. Connect the SmartNode to the network” on page 42. Otherwise, refer to the following sections to change the addresses and network masks.
Connect with the serial interface The Console port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and cable (see figure 25) between the SmartNode’s Console port and a PC or workstation’s RS-232 serial interface. Activate the terminal emulation program on the PC or workstation that supports the serial interface (e.g. HyperTerm).

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
Figure 25. Connecting to the terminal

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode
Login Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to display. Type the factory default login: administrator and leave the password empty. Press the Enter key after the pass word prompt.
login:administrator
172.16.40.1> After you have successfully logged in you are in the operator execution mode, indicated by > as command line prompt. With the commands enable and configure you enter the configuration mode.
172.16.40.1>enable
172.16.40.1#configure
172.16.40.1(cfg)#
Changing the IP address Select the context IP mode to configure an IP interface.
172.16.40.1(cfg)#context ip router
172.16.40.1(ctx-ip)[router]# Now you can set your IP address and network mask for the interface eth0. Within this example a class C net work (172.16.1.0/24) is assumed. The IP address in this example is set to 172.16.1.99 (you should set this to an unused IP address on your network).
172.16.40.1(ctx-ip)[router]#interface eth0
172.16.40.1(if-ip)[eth0]#ipaddress 172.16.1.99 255.255.255.0
2002-10-29T00:09:40 : LOGINFO : Link down on interface eth0.
2002-10-29T00:09:40 : LOGINFO : Link up on interface eth0.
172.16.1.99(if-ip)[eth0]# Copy this modified configuration to your new start-up configuration. Upon the next start-up the system will initialize itself using the modified configuration.
172.16.1.99(if-ip)[eth0]#copy running-config startup-config
172.16.1.99(if-ip)[eth0]# The SmartNode can now be connected with your network.

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION
Depending whether you connect the SmartNode to a host directly or via a hub or switch either straight- through wired or cross-over cables must be used (see figure 26).

Figure 26. Connecting the SmartNode to the network
You can check the connection with the ping command to another host on the local LAN.
172.16.1.99(if-ip)[eth0]#ping Respectively from the host: ping 172.16.1.99
Download a configuration note to your PC from the support page of Patton’s Inalp web server (http://www.inalp.ch/en/support/confignotes/) that matches your application. Adapt the configuration as described in the configuration note to your network (do not forget to modify the IP address) and copy the modified configuration to a TFTP server. The SmartNode can now load its configuration from this server.
In this example we assume the TFTP server on the host with the IP address 172.16.1.11 and the configuration named SN.cfg in the root directory of the TFTP server.
172.16.1.99(if-ip)[eth0]#copy tftp://172.16.1.11/SN.cfg startup-config
Download...100%

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode
172.16.1.99(if-ip)[eth0]# After the SmartNode has been rebooted the new start up configuration will be activated.
172.16.1.99(if-ip)[eth0]#reload
Running configuration has been changed.
Do you want to copy the 'running-config' to the 'startup-config'?
Press 'yes' to store, 'no' to drop changes : no
Press 'yes' to restart, 'no' to cancel : yes
The system is going down
The bootloader ensures that basic operations, network access, and downloads are possible in case of interrupted or corrupted application image downloads. It also offers console access to the Bootloader and the capability for downloading application images (e.g. SmartWare) via the serial link of the console.
Start Bootloader To start the Bootloader, power on the SmartNode while pressing the reset button. Open a Telnet session to the SmartNode via one of the Ethernet interfaces, or open a CLI session via the console port (if available on the SmartNode). The login display will appear. Using the credentials admin / patton, log in to the SmartNode. The following prompt will be displayed:
Type help to display an overview of the available commands.
RedBoot> · Bootloader 43

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode
1 RedBoot> fis load Copies the SmartWare application image from the persistent memory (flash:) to the volatile memory (RAM) from where it will be executed.
2 RedBoot> go -s factory-config Starts the SmartWare application telling it to use ‘factory-config’ as startup configuration. You can also start-up with any other configuration available in the persistent memory (nvram:) by pro viding its name instead of ‘factory-config’.
Load a new application image (SmartWare) via TFTP The following procedure downloads the application image (SmartWare) for the mainboard. See the note below on how to download the respective CLI description file.
RedBoot> ip_address - l local_ip_address [/mask_len]
Sets the IP address and subnet mask of the Ethernet interface 0/0 which shall be used to receive the new application image. mask_len is the length of the network address (or the number of 1’s within the subnet mask). See Note below.
RedBoot> ip_address -g gateway Sets the IP address of the default gateway.
RedBoot> ping -h tftp-server_ip_address Tests the connectivity to the TFTP server.
4 RedBoot> load -r -v -h host -b base_address file_name
Downloads an application image into the vola tile memory (RAM) from where the SmartNode could directly execute it. host: IP address of the TFTP server base_address: memory location where to store the application image. Use the default address 0x1800100 file_name: path and name of the file on the TFTP server. Note: use the image file that con tains the whole application, not the image parts.
5 RedBoot> fis delete -n 1 Deletes the first application image. Reply with ‘y’ to the confirmation request.
6 RedBoot> fis create Stores the downloaded application image to the permanent memory (flash:). Reply with ‘y’ to the confirmation request.
7 RedBoot> fis list -l Checks whether the image has been success fully stored, whether it is the desired Release and Build, and whether it is valid.

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode
8 RedBoot> go Starts the application image that was down loaded into the volatile memory (RAM).
Note With the Bootloader, only the Ethernet interface 0/0 is available. The Boot loader applies the IP address, subnet mask, and default gateway that were last configured by the Bootloader itself or by another application (e.g. Smart Ware). If an application configured the Ethernet interface 0/0 to use DHCP, the Bootloader will also use DHCP to learn the interface configuration. It can receive and apply the IP address, subnet mask, default gateway, and default (TFTP) server (transmitted as basic DHCP information ‘Next server IP address’).
RedBoot> ip -l 172.16.40.98/19 RedBoot> ip -g 172.16.32.1 RedBoot> ping -h 172.16.32.100 Network PING - from 172.16.40.98 to 172.16.32.100 PING - received 10 of 10 expected
RedBoot> load -r -v -h 172.16.32.100 -b 0x1800100 /Sn4xxx/image.bin Using default protocol (TFTP) - Raw file loaded 0x01800100-0x0199ca6b, 1689964 bytes, assumed entry at 0x01800100
RedBoot> fis delete -n 1 Delete image 1 - continue (y/n)? y ... Erase from 0x60030000-0x601cc974:
RedBoot> fis create Use address 0x01800100, size 1684402 ? - continue (y/n)? y ... Erase from 0x60030000-0x601cb3ba: Program from 0x00011eec-0x00011ef4 at 0x60030000: Program from 0x01800100-0x0199b4b2 at 0x60030008: Program from 0x00011eec-0x00011ef4 at 0x60030000: . Image successfully written to flash
RedBoot> fis list -l Id Address Length State Description Entry Load Addr Version 1 0x60030000 1693438 valid SmartWare R2.10 BUILD28015 0x01800100 0x01800100 V2.10
RedBoot> go Starting 'SmartWare R2.10 BUILD28015' at 0x01800100 via 0x01800100
Step Command Purpose · Bootloader 45

SmartNode 4520 & 4110 Series User Manual 4 • Getting started with the SmartNode
Load a new application image (SmartWare) via the serial link The Bootloader supports the ‘X-Modem’ and ‘Y-Modem’ protocols to download application images via the serial link of the console. Do the following to initiate the download:
1 RedBoot> load -r -v -m { xmodem | ymodem } -b base_address
Downloads an application image into the volatile memory (RAM) from where the SmartNode could directly execute it. ‘xmodem’ or ‘ymodem’: Specify the protocol to be used, X- Modem or Y-Modem base_address: memory location where to store the application image. Use the default address 0x1800100 Execute the above RedBoot command first, then start the trans fer from the terminal program with the command ‘Send file via X-Modem’ (or similar).
5 RedBoot> fis delete -n 1 Deletes the first application image. Reply with ‘y’ to the confirmation request.
6 RedBoot> fis create Stores the downloaded application image to the permanent memory (flash:). Reply with ‘y’ to the confirmation request.
7 RedBoot> fis list -l Checks whether the image has been successfully stored, whether it is the desired Release and Build, and whether it is valid.
8 RedBoot> go Starts the application image that was downloaded to the vola tile memory (RAM).
For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the SmartNode Series SmartWare Software Configuration Guide available online at www.patton.com/ manuals.
Step Command Purpose · Additional information 46

Status LEDs 48

SmartNode 4520 & 4110 Series User Manual 5 • LEDs status and monitoring
This chapter describes SmartNode gateway router front panel LEDs. Figure 27 shows SmartNode 4520 Series LEDs, figure 28 on page 49 shows SmartNode 4110 Series LEDs. LED definitions are listed in table 9 on page 50.

Figure 27. Examples of SN4520 Series front panels
Status LEDs 48

SmartNode 4520 & 4110 Series User Manual 5 • LEDs status and monitoring

Figure 28. Examples of SN4110 Series front panels
Status LEDs 49

SmartNode 4520 & 4110 Series User Manual 5 • LEDs status and monitoring
Table 9. SmartNode LED Indications
Power When lit, indicates power is applied. Off indicates no power applied.
Run When lit, indicates normal operation. Flashes once per second during boot (startup).
VoIP Link When lit, indicates the gateway is registered on a gatekeeper, media gateway con troller, associated to a remote unit, or has an active VoIP connection. Off indicates the unit is not configured or registered and has no active VoIP connection. Flashing green indicates that the unit is attempting or has failed to associate/register
FXS (each port) Off indicates on-hook condition. Solid green when off-hook. Flashes to follow ring cadence.
FXO (each port) Off indicates on-hook condition. Solid green when off-hook. Flashes to follow ring cadence.
Ethernet (each port) • Link: Lit when Ethernet link is up.
LED Description · Status LEDs 50


SmartNode 4520 & 4110 Series User Manual 6 • Contacting Patton for assistance
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems:
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro phes may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Introduction 52

SmartNode 4520 & 4110 Series User Manual 6 • Contacting Patton for assistance
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 53


SmartNode 4520 & 4110 Series User Manual A • Compliance
We certify that the apparatus identified in this document conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.
D R M Green
European Compliance Services Limited.
Oakdene House, Oak Road
Swindon, Wilts SN6 8TD, UK
Watchfield, · Compliance 55

SmartNode 4520 & 4110 Series User Manual A • Compliance
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reason able protection from such interference in a commercial installation. However, there is no guarantee that inter ference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equip ment and receiver are on different branches).
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you dis connect the equipment until the problem is resolved.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission or corporation commission for information.
This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is confirmed by the registration number. The abbreviation, IC, before the registration number signifies that reg istration was performed based on a Declaration of Conformity indicating that Industry Canada technical spec ifications were met. It does not imply that Industry Canada approved the equipment.
This Declaration of Conformity means that the equipment meets certain telecommunications network protec tive, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be con nected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The
Radio and TV Interference (FCC Part 15) 56

SmartNode 4520 & 4110 Series User Manual A • Compliance
customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment mal functions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.
Industry Canada Notice (FXO Ports) 57


SmartNode 4520 & 4110 Series User Manual B • Specifications
One or two 4-channel DSPs
Short haul loop 1.1 km @3REN
EuroPOTS (ETSI EG201 188)
Programmable AC impedance, feeding, and ring voltage; On-Hook Voltage 29VDC
Caller-ID Type-1/2 FSK and ITU V.23/Bell 202 generation
2 10/100 Full Duplex/Autosensing Ethernet RJ-45
Voice codes:
G.168 echo cancellation
8 parallel voice connections
DTMF detection and generation
Carrier tone detection and generation
Silence suppression and comfort noise
Configurable tones (dial, ringing, busy)
Configurable transmit packet length
Fax and modem support
G.711 transparent FAX
Fax over IP (FoIP)
T.38 Fax relay (9.6 k, 14.4 k)
2-wire Loopstart, RJ-11/12 · Configurable dejitter buffer

SmartNode 4520 & 4110 Series User Manual B • Specifications
H.323v4
ISDN over IP (ISoIP)
Local switching; Interface huntgroups
IPv4 router; RIPv1, v2 (RFC 1058 and 2453)
ICMP redirect (RFC 792); Packet fragmentation
DiffServe/ToS set or queue per header bits
Pocket Policing discards excess traffic
802.1p VLAN tagging

SmartNode 4520 & 4110 Series User Manual B • Specifications
IPSEC AH & ESP Modes
Manual Key; IKE optional
Industry standard CLI with local console (RJ-45, RS-232, 9600 bps, 8, N, 1), and remote Telnet access
TFTP configuration & firmware loading
SNMP v1 agent (MIB II and private MIB)
Built-in diagnostic tools (trace, debug)
Java™ Applet; HPOV Integration with NNM
Operating temperature 32–104°F (0–40°C)
Operating humidity 5–80% (non condensing)
CPU Motorola MPC859 operating at 50 MHz
Memory:
7.3W x 1.6H x 6.1D in. (18.5H x 4.1W x 15.5D cm)
See table 10.
Table 10. SmartNode weight and maximum power specifications
SmartNode model Weight Maximum power dissipation
SN4112/SN4522 30.5 oz/500 g 6W
SN4114/SN4524 30.5 oz/500 g 8W
SN4116/SN4526 24.4 oz/400 ga
SN4118/SN4528 24.4 oz/400 ga 15W
a. Excluding external power supply
AES/DES/3DES Encryption · Management 61

SmartNode 4520 & 4110 Series User Manual B • Specifications
The terminal block header to which the wires are secured pro vides the disconnect for the SmartNode. Take proper measures to ensure that it is not permanently fastened to the receptacle mounted on the chassis.
AC version Internal power supply 100–240 VAC, 50/60 Hz, 200 mA
DC version 12 VDC, 1.25 A
All SmartNode devices have assigned sysObjectID (.iso.org.dod.internet.mgmt.mib-2.system.sysObjectID) numbers (see table 11).
Table 11. SmartNode Models and their Unique sysObjectID
SN4112-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.5 1.3.6.1.4.1.1768.2.4.5.5
SN4112-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.19 1.3.6.1.4.1.1768.2.4.5.19
SN4114-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.6 1.3.6.1.4.1.1768.2.4.5.6
SN4114-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.20 1.3.6.1.4.1.1768.2.4.5.20
SN4114-2JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.12 1.3.6.1.4.1.1768.2.4.5.12
SN4116-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.7 1.3.6.1.4.1.1768.2.4.5.7
SN4116-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.21 1.3.6.1.4.1.1768.2.4.5.21
SN4116-4JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.13 1.3.6.1.4.1.1768.2.4.5.13
SN4118-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.8 1.3.6.1.4.1.1768.2.4.5.8
SN4118-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.22 1.3.6.1.4.1.1768.2.4.5.22
SmartNode Model SysObjectID · Power supply 62

SmartNode 4520 & 4110 Series User Manual B • Specifications
Table 11. SmartNode Models and their Unique sysObjectID (Continued)
SN4118-4JS4JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.14 1.3.6.1.4.1.1768.2.4.5.14
SN4524-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.1 1.3.6.1.4.1.1768.2.4.5.1
SN4526-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.3 1.3.6.1.4.1.1768.2.4.5.3
SN4528-JS .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.4 1.3.6.1.4.1.1768.2.4.5.4
SN4524-2JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.9 1.3.6.1.4.1.1768.2.4.5.9
SN4526-4JS2JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.10 1.3.6.1.4.1.1768.2.4.5.10
SN4528--4JS4JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.11 1.3.6.1.4.1.1768.2.4.5.11
SN4522-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.15 1.3.6.1.4.1.1768.2.4.5.15
SN4524-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.16 1.3.6.1.4.1.1768.2.4.5.16
SN4526-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.17 1.3.6.1.4.1.1768.2.4.5.17
SN4528-JO .iso.org.dod.internet.private.enterprises.patton.products.sn4xxx.18 1.3.6.1.4.1.1768.2.4.5.18
According to table 11, an SNMP get request to .iso.org.dod.internet.mgmt.mib-2.system.sysObjectID of a Smart Node 4112-JS device reads out a numeric OID of 1.3.6.1.4.1.1768.2.4.5.5, which represents a SmartNode 4112 device. The mapping of the sysObjectID to each of the SmartNode model is realized with the Smart Node product identification MIB.
The SNMP agent running in SmartWare is SNMP version 1 (SNMPv1) compliant. SNMP version 2 (SNMPv2) and SNMP version 3 (SNMPv3) are not currently supported.
Identification of the SmartNode devices via SNMP 63
SmartNode Model SysObjectID


SmartNode 4520 & 4110 Series User Manual C • Cabling
This section provides information on the cables used to connect the SmartNode and the interface cards to the existing network infrastructure and to third party products.

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION
The SmartNode can be connected to a serial terminal over its serial console port, as depicted in figure 29.

VoIP Gateway Router ToIP Integrated Access Device SmartNode 4524
Figure 29. Connecting a serial terminal
Introduction 65

SmartNode 4520 & 4110 Series User Manual C • Cabling

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION
Ethernet devices (10Base-T/100Base-T) are connected to the SmartNode over a cable with RJ-45 plugs. Use a cross-over cable to a host, or a straight cable to a hub. See figure 30 (host) and figure 31 on page 67 (hub) for the different connections.

Figure 30. Ethernet cross-over
Ethernet 10Base-T and 100Base-T 66


SmartNode 4520 & 4110 Series User Manual C • Cabling
Figure 31. Ethernet straight-through
Ethernet 10Base-T and 100Base-T 67

SmartNode 4520 & 4110 Series User Manual C • Cabling

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION
Applicable to SmartNodes equipped with FXS ports. The FXS ports are connected to analog terminals (phones, fax machines, answering machines) via cables terminated with RJ-11 connectors (see section “FXS port” on page 72 for details on port pinouts).

Figure 32. Connecting an FXS device
Analog FXS 68

SmartNode 4520 & 4110 Series User Manual C • Cabling

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to volt age, current, anticipated temperature, flammability, and mechanical serviceability. CAUTION
Applicable to SmartNodes equiped with FXO ports. The FXO ports are connected to analog phone lines via cables terminated with RJ-11 connectors (see section “FXO port” on page 72 for details on port pinouts).

Figure 33. Connecting to an FXO line socket
Analog FXO 69


SmartNode 4520 & 4110 Series User Manual D • Port pin-outs
This section provides pin-out information for the ports of the SmartNode.
Figure 34. EIA-561 (RJ-45 8-pin) port
Table 12. RJ-45 socket
2 TX-
3 RX+
6 RX-
Pin Signal · Introduction 71

SmartNode 4520 & 4110 Series User Manual D • Port pin-outs
The FXS ports use an RJ-11 connector with 6 positions. The midle two positions 3 and 4 are used according to table 13.
Table 13. RJ-11 socket
The FXO ports use an RJ-11 connector with 6 positions. The midle two positions 3 and 4 are used according to table 14.
Table 14. RJ-11 socket

configuration
Introduction 74

SmartNode 4520 & 4110 Series User Manual E • SmartNode 4110 Series factory configuration
The factory configuration settings for SmartNode 4110 Series devices are as follows:
# 4110 Series # # Factory configuration file #
sntp-client sntp-client server primary 129.132.2.21 port 123 version 4
system ic voice 0 low-bitrate-codec g729
interface eth0 ipaddress dhcp tcp adjust-mss rx mtu tcp adjust-mss tx mtu
port ethernet 0 0 medium auto encapsulation ip bind interface eth0 router no shutdown
context ip router · Introduction 74

configuration
Introduction 76

SmartNode 4520 & 4110 Series User Manual F • SmartNode 4520 Series factory configuration
The factory configuration settings for SmartNode 4520 Series devices are as follows:
# 4520 Series # # Factory configuration file #
dns-relay sntp-client sntp-client server primary 129.132.2.21 port 123 version 4
ic voice 0 low-bitrate-codec g729 profile napt NAPT
profile dhcp-server DHCP network 192.168.1.0 255.255.255.0 include 1 192.168.1.10 192.168.1.99 lease 2 hours default-router 1 192.168.1.1 domain-name-server 1 192.168.1.1
interface eth0 ipaddress dhcp use profile napt NAPT tcp adjust-mss rx mtu tcp adjust-mss tx mtu
interface eth1 ipaddress 192.168.1.1 255.255.255.0 tcp adjust-mss rx mtu tcp adjust-mss tx mtu
context ip router dhcp-server use DHCP
port ethernet 0 0 medium auto encapsulation ip bind interface eth0 router no shutdown
port ethernet 0 1 medium auto encapsulation ip bind interface eth1 router no shutdown
system · context ip router · Introduction 76

Introduction 78

SmartNode 4520 & 4110 Series User Manual G • Installation checklist
This appendix lists the tasks for installing a SmartNode 4520 or 4110 Series router (see table 15) . Make a copy of this checklist and mark the entries as you complete each task. For each SmartNode 4520 or 4110 Series router, include a copy of the completed checklist in your site log.
Table 15. Installation checklist
Task Verified by Date
Network information available & recorded in site log
Site power voltages verified
Installation site pre-power check completed
All printed documents available
SmartWare release & build number verified
Rack, desktop, or wall mounting of chassis completed
Initial electrical connections established
ASCII terminal attached to console port
Cable length limits verified