EN
Patton electronic logo
Official user manual

Patton electronic 3201

12 pages·772 KB·Network Router·PDF·ENDEFRITNLJA
Patton electronic 3201
Table of Contents 15 sections 1.0 Power up the router · 1.1 Models with external AC adaptor · 1.2 Models with external DC power supply · 1.3 Power-up indication · … ShowHide
Page 1 of the Patton electronic 3201 user manual — DiamondLink™ Model 3201 & 3241 G.SHDSL Router
Page 1 · click to enlarge
Page 1

DiamondLink™ Model 3201 & 3241 G.SHDSL Router

Quick Start Guide

Patton electronic 3201 — DiamondLink™ Model 3201 & 3241 G.SHDSL Router diagram (page 1)
Fig. 1 · DiamondLink™ Model 3201 & 3241 G.SHDSL Router
Document Number03321U7-001 Rev. B Part Number: 07M3201-QS Revised: October 15, 2008
Sales Office+1 (301) 975-1000 Technical Support: +1 (301) 975-1007
E-mailsupport@ patton.com
WWWwww.patton.com
Page 2 of the Patton electronic 3201 user manual — CAUTION
Page 2 · click to enlarge
Page 2
  • This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel.

WARNING

  • The external power adapter shall be a listed Limited Power Source. The mains outlet that is utilized to power the devise shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker.
  • If an AC power adapter is used, ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
  • Hazardous network voltages are present in WAN ports regardless of whether power to the unit is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the device first.
  • Do not work on the system or connect or disconnect cables during periods of lightning activity.

1.0 Power up the router

The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flam- mability, and mechanical serviceability.

CAUTION

Your G.SHDSL router comes with one of the following power supply options:

  • External AC adaptor with included power cord
  • External DC power supply

1.1 Models with external AC adaptor

1. Connect female plug of the AC power cord to the AC adaptor provided. 2. Connect the barrel-type connector of the AC adaptor to the Power connector on the DiamondLink router. 3. Insert the male plug of the AC power cord into an AC power outlet (100–240 VAC).
Page 3 of the Patton electronic 3201 user manual — 2.0 Configure the IP address
Page 3 · click to enlarge
Page 3
Patton electronic 3201 — 1.2 Models with external DC power supply diagram (page 3)
Fig. 2 · 1.2 Models with external DC power supply

Figure 1. 48VDC power supply

1.2 Models with external DC power supply

1. Strip insulation 1/4-inch from the electrical wires that will connect the DC power source to the 48VDC

power supply terminal block (see figure 1). 2. Connect the negative (-) terminal from the power source with to the negative (-) terminal on

the power supply. 3. Connect the positive (+) terminal from the power source with to the positive (+) terminal on

the power supply 4. Connect the 48VDC output barrel-type plug to the Power connector on the DiamondLink.

1.3 Power-up indication

The Power LED blinks as the DiamondLink is powering up. When the Power LED stops blinking and remains lit, the DiamondLink is ready for you to configure.

2.0 Configure the IP address

The DiamondLink is shipped with a factory-configured IP address assigned to the Ethernet LAN port (green out- line). The address is 192.168.200.10/24. In most cases, you must change the address to be on the same subnet as your PC, as described in the procedures below. If you are not sure which IP address to use for your installa- tion, contact your network administrator.

Page 4 of the Patton electronic 3201 user manual — 2.1 Connect a PC and log in
Page 4 · click to enlarge
Page 4

2.1 Connect a PC and log in

1. Using the included combination RS232/Ethernet cable and DB9-RJ45 adapter, connect a PC’s serial port

to the on the DiamondLink’s (red) Console port (see figure 2).

Patton electronic 3201 — 2.1 Connect a PC and log in diagram (page 4)
Fig. 3 · 2.1 Connect a PC and log in

Figure 2. Connecting DiamondLink to the PC’s serial port

2. Start a HyperTerminal session on the PC using the settings:

9600 bps, 8 data bits, 1 stop bit, no parity, no flow control 3. Log in to the DiamondLink using the factory-default login and password:

Loginsuperuser Password: superuser Login successful

2.2 Modify the IP address

1. Display current IP interface settings for the DiamondLink Ethernet LAN port.

→ ip list interfaces IP Interfaces: ID | Name | IP Address | DHCP | Transport ---| 1 | ip1 | 192.168.200.10 | disabled |

2. Modify the IP address for the LAN port according to your network requirements.

→ ip set interface ip1 ipaddress 10.10.10.5 255.255.255.0

subnet as your PC.

3. Verify the new address is correct and save it in system boot memory.

→ ip list interfaces → system config save →

Page 5 of the Patton electronic 3201 user manual — 4.0 Log onto the web management interface
Page 5 · click to enlarge
Page 5

3.0 Connect to the local IP network

Now you can connect the DiamondLink to your local IP network and complete the remaining configuration from your PC using a standard web browser. Connect the DiamondLink’s (green) Ethernet port to the same Ethernet segment as your PC (see figure 3). Press the MDI-X switch until the Ethernet Link LED turns on.

Patton electronic 3201 — 3.0 Connect to the local IP network diagram (page 5)
Fig. 4 · 3.0 Connect to the local IP network

Figure 3. Connecting the DiamondLink to the local IP network

You can check the network connection with the ping command. For example, you would ping 10.10.10.5 from your PC.

4.0 Log onto the web management interface

You will now access the web management Graphical User Interface (GUI) to configure the DiamondLink using a standard web browser (such as Internet Explorer or Netscape browser). 1. At your PC, open a web browser and enter the IP address you assigned to the DiamondLink’s Ethernet

LAN port in step 2 of section 2.2 “Modify the IP address” on page 4. 2. Log in to the web management home page using the username superuser and the password superuser.

Patton electronic 3201 — 4.0 Log onto the web management interface diagram (page 5)
Fig. 5 · 4.0 Log onto the web management interface

Figure 4. DiamondLink web management home page

Page 6 of the Patton electronic 3201 user manual — A.0 Customer and Technical Support
Page 6 · click to enlarge
Page 6

5.0 Connect the G.SHDSL port

1. Obtain single-twisted-pair cable with an RJ-11 plug connector at each end. 2. Plug one end of the cable into the RJ-11socket (yellow colored port labeled LINE ) on the

DiamondLink Router. 3. Plug the other end of the cable into the RJ-11 wall socket that provides your G.SHDSL service. 4. When a DSL link is established, the front panel WAN Link LED will turn on.

6.0 Additional Information

Refer to the DiamondLink User Manual located on the CD-ROM shipped with your Model 3201 or 3241 and available online at www.patton.com/manuals for detailed information about:

  • Installing, configuring, operating, and troubleshooting,
  • Warranty, trademark, & compliance

A.0 Customer and Technical Support

Toll-Free VoIP support: call sip:support@patton.com with a VoIP SIP phone Online support: www.patton.com E-mail support: support@patton.com—answered within 1 business day Telephone support:

  • Standard: +1 (301) 975-1007 (USA), Monday–Friday: 8:00 am to 5:00 pm EST (1300 to 2200 UTC/GMT)
  • Alternate: +41 (0)31 985 25 55 (Switzerland), Monday–Friday: 8:00 am to 5:00 pm CET (0900 to 1800 UTC/GMT)
Fax+1 (253) 663-5693 (USA) or +41 (0)31 985 25 26 ( Switzerland)
Page 7 of the Patton electronic 3201 user manual — B.0 Compliance Information
Page 7 · click to enlarge
Page 7

B.0 Compliance Information

B.1 Compliance

EMC• FCC Part 15, Class A
  • EN55022, Class A
  • EN55024
Safety• UL 60950-1/CSA C22.2 N0. 60950-1
  • IEC/EN60950-1
  • AS/NZS 60950-1
PSTN Regulatory• FCC Part 68
  • CS-03
  • AS/ACIF S043:2003

B.2 FCC Part 68 (ACTA) Statement

This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone com- pany will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you discon- nect the equipment until the problem is resolved. Connection to party line service is subject to state tariffs. Contact the state public utility commission, public ser- vice commission or corporation commission for information.

Page 8 of the Patton electronic 3201 user manual — 2.3 Industry Canada Notice
Page 8 · click to enlarge
Page 8

2.3 Industry Canada Notice

This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is con- firmed by the registration number. The abbreviation, IC, before the registration number signifies that registra- tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment. This Declaration of Conformity means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.

B.4 Radio and TV Interference (FCC Part 15)

This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accor- dance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the fol- lowing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

B.5 EC Declaration of Conformity

Product Description: DiamondLink™ Models 3201 & 3241 We certify that the apparatus identified above conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equip- ment and the mutual recognition of their conformity.

The safety advises in the documentation accompanying the products shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.

The signed Declaration of Conformity can be downloaded from www.patton.com/certifications/.

Page 9 of the Patton electronic 3201 user manual — 2.3 Industry Canada Notice
Page 9 · click to enlarge
Page 9

B.6 Authorized European Representative

D R M Green European Compliance Services Limited. Avalon House, Marcham Road Abingdon, Oxon OX14 1UD, UK

Page 10 of the Patton electronic 3201 user manual — Copyright statement
Page 10 · click to enlarge
Page 10

Copyright statement Copyright © 2008, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document.

Trademarks statement The term DiamondLink is a trademark of Patton Electronics Company. All other trademarks presented in this doc- ument are the property of their respective owners.

Warranty, Trademark, & Compliance Information For warranty, trademark and compliance information, refer to the DiamondLink 3201 & 3241 User Manual located on the CD-ROM that came with your router or available online at www.patton.com.

In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.

Page 11 of the Patton electronic 3201 user manual — Copyright statement
Page 11 · click to enlarge
Page 11
Page 11 of the Patton electronic 3201 user manual — Copyright statement
Page 12 of the Patton electronic 3201 user manual — Copyright statement
Page 12 · click to enlarge
Page 12
Page 12 of the Patton electronic 3201 user manual — Copyright statement
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 3201

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 3201

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 3201 manual PDF

12 pages·772 KB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…