Quick Start Guide


The interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flam- mability, and mechanical serviceability.
Your router comes with one of the following power supply options:
1.1 Models with external AC adaptor
1.2 Models with internal AC power supply

1.3 Models with internal DC power supply
1.4 Power-up indication
The Power LED blinks as the IPLink is powering up. When the Power LED stops blinking and remains lit, the IPLink is ready for you to configure.
The IPLink is shipped with a factory-configured IP address assigned to the Ethernet LAN port (green outline). The address is 192.168.200.10/24. In most cases, you must change the address to be on the same subnet as your PC, as described in the procedures below. If you are not sure which IP address to use for your installation, contact your network administrator.
2.1 Connecting a PC and logging in
to the IPLink’s Console port (see figure 1).

ipLink Gateway High Speed WAN Access Router Model 2603
Figure 1. Connecting IPLink to the PC’s serial port
9600 bps, 8 data bits, 1 stop bit, no parity, no flow control 3. Log in to the IPLink using the factory-default login and password:

2.2 Modifying the IP address
→ ip list interfaces IP Interfaces: ID | Name | IP Address | DHCP | Transport ---| 1 | ip1 | 192.168.200.10 | disabled |
→ ip set interface ip1 ipaddress 10.10.10.5 255.255.255.0
subnet as your PC.
→ ip list interfaces → system config save → Now you can connect the IPLink to your local IP network and complete the remaining configuration from your PC using a standard web browser.
Connect the IPLink’s (green) Ethernet port to the same Ethernet segment as your PC (see figure 2).
nect the Model 2620’s Ethernet port to the IP network.
If you have a Model 2603, press the MDI-X switch until the Ethernet Link LED turns on.

Figure 2. Connecting the IPLink to the local IP network (Model 2603/K shown)

You can check the network connection with the ping command. For example, you would ping 10.10.10.5 from your PC.
You will now access the web management Graphical User Interface (GUI) to configure the IPLink using a stan- dard web browser (such as Internet Explorer or Netscape browser). 1. At your PC, open a web browser and enter the IP address you assigned to the IPLink’s Ethernet LAN port
in step 2 of section 2.2 “Modifying the IP address” on page 4. 2. Log in to the web management home page using the username superuser and the password superuser.

Figure 3. IPLink web management home page
“Complete the installation” on page 6).
The IPLink 2603/T, 2603/K, and 2620 come with a T1/E1 WAN interface (presented on an RJ-48C connector with selectable line impedances of 100-ohms for T1 and 120-ohms for E1 lines). The Model 2603 has one RJ- 48C connector and the 2620 has two. The Model 2603/K and 2620/KK also come with dual BNC connectors for alternate connection to unbalanced 75-ohm E1 lines. To connect the WAN port on a Model 2620 or Model 2603/T, or if you plan to use the RJ-48C port on a 2603/K, refer to section “Connecting to the RJ-48C WAN port”. Otherwise, refer to section “Connecting to the unbalanced 75-ohm TX and RX WAN ports (Model 2603/K and 2620/KK only)” to install cables onto the BNC connectors on the 2603/K and 2620/KK models.

Connecting to the RJ-48C WAN port 1. Obtain a twisted-pair cable with an RJ-48C plug connector at each end. 2. Plug one end of the cable into the RJ-48C socket (labeled WAN) on the IPLink Router. 3. Plug the other end of the cable into the T1/E1 device. 4. Repeat steps 1 through 3 to install the remaining WAN cables on a Model 2620
Connecting to the unbalanced 75-ohm TX and RX WAN ports (Model 2603/K and 2620/KK only) 1. Obtain a coaxial cable with a BNC connector at each end. 2. Plug one end of the cable into the transmit socket (labeled TX) on the IPLink Router. Plug the other end
of the cable into the receive port of the E1 device. 3. Plug one end of the cable into the receive socket (labeled RX) on the IPLink Router. Plug the other end of
the cable into the transmit port of the E1 device.
To finish configuring your IPLink, and for detailed information about installing, configuring, operating, and trou- bleshooting, refer to the Models 2603, 2621, and 2635 IPLink Series High Speed Routers User Guide and appli- cation notes, available on the enclosed Patton CD-ROM or at www.patton.com
Toll-Free VoIP support: call sip:support@patton.com with a VoIP SIP phone Online support: www.patton.com E-mail support: support@patton.com—answered within 1 business day Telephone support:

B.1 Radio and TV Interference (FCC Part 15)
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accor- dance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the fol- lowing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
B.2 EC Declaration of Conformity
Product Description: IPLink 2603, 2620 We certify that the apparatus identified above conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equip- ment and the mutual recognition of their conformity.
The safety advises in the documentation accompanying the products shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.
The signed Declaration of Conformity can be downloaded from www.patton.com/certifications/.
B.3 FCC Part 68 (ACTA) Statement
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company. The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone com- pany will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary. The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service. If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you discon- nect the equipment until the problem is resolved.

Connection to party line service is subject to state tariffs. Contact the state public utility commission, public ser- vice commission or corporation commission for information.
B.4 Industry Canada Notice
This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is con- firmed by the registration number. The abbreviation, IC, before the registration number signifies that registra- tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment. This Declaration of Conformity means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.
Copyright statement Copyright © 2005, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document.
Trademarks statement The term IPLink is a trademark of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.
Warranty, Trademark, & Compliance Information For warranty, trademark and compliance information, refer to the Models 2603, 2621, and 2635 IPLink Series High Speed Routers User Guide located on the CD-ROM that came with your router or available online at www.patton.com.
In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.