Page 1 of the Patton electronic 2174 user manual — SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
Page 1 · click to enlarge
Page 1

USER MANUAL

MODEL 2174 CopperLINK™ High Speed Ethernet Extender

Patton electronic 2174 — USER MANUAL diagram (page 1)
Fig. 1

This is a Class A device and is not intended for use in a residential environment.

Patton electronic 2174 — USER MANUAL diagram (page 1)
Fig. 2

Part# 07M2174-UM Rev. A Revised 9/23/11

SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

An ISO-9001Certified · Company

Page 2 of the Patton electronic 2174 user manual — CONTENTS
Page 2 · click to enlarge
Page 2

CONTENTS

1.0 Warranty Information 4 1.1 Regulatory Information 4

EMC Directive: 4 Low-Voltage Direcive (Safety): 4 PSTN: 4 1.2 Radio and TV Interference (FCC Part 15) 4 1.3 CE Declaration of Conformity 5 1.4 Authorized European Representative 5 1.5 Service 5 1.6 Safety When Working With Electricity 6

2.0 General Information 8 2.1 Features 8 2.2 Description 8

3.0 Installation 9 3.1 Connecting the Line Interface 11

Connecting the Line Interface for Model 2174/EUI or 2174/TB.. 11 Connecting the Line Interface for Model 2174/BNC 12 3.2 Connecting the 10/100Base-T Ethernet Interface 12 3.3 Connecting Power 13

4.0 Configuration 13 4.1 Configuring the Hardware DIP switches 13 4.2 Configuring DIP Switch S1 14

Switch S1-1: Local/Remote Configuration 15 Switches S1-2 and S1-3: Symmetric/Asymmetric Operation 15 Switch S1-5: General Protection (Signal to Noise Ratio) 15

5.0 Operation 16 5.1 Front Panel LED Status Monitors 16

A Specifications 17 A.1 LAN Connection 17 A.2 Transmission Line 17 A.3 CopperLINK Line Rate and CopperLINK Distance 17 A.4 LED Status Indicators 17 A.5 Power Supply 17 A.6 Temperature Range 17 A.7 Humidity 17 A.8 Dimensions 17

B Model 2174 Series Factory Replacement Parts and Accessories 18

C Model 2174 Series Interface Pin Assignment 19 C.1 10/100Base-T Interface 19

Page 4 of the Patton electronic 2174 user manual — 1.2 RADIO AND TV INTERFERENCE (FCC PART 15)
Page 4 · click to enlarge
Page 4

1.0 WARRANTY INFORMATION

Patton Electronics warrants all Model 2174 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.

This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not performs as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics spe cifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1.1 REGULATORY INFORMATION

EMC Directive:

  • FCC Part 15, Class A
  • EN55022, Class A
  • EN55024
  • A-tick

Low-Voltage Direcive (Safety):

  • IEC/EN60950-1, 2nd Edition
  • AS/NZS 60950-1, A-tick

PSTN:

  • This device is not intended nor approved for connection to the PSTN

1.2 RADIO AND TV INTERFERENCE (FCC PART 15)

This device generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufac turer’s instructions-may cause interference to radio and television recep

Page 5 of the Patton electronic 2174 user manual — 1.5 SERVICE
Page 5 · click to enlarge
Page 5

tion. The device has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable pro tection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular instal lation. If the device does cause interference to radio or television recep tion, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the follow ing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equip ment into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.3 CE DECLARATION OF CONFORMITY

Patton Electronics, Inc declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC relating to electromagnetic compatibility and Directive 2006/95/EC relating to electrical equipment designed for use within cer tain voltage limits. The Declaration of Conformity may be obtained from Patton Electronics, Inc at www.patton.com/certifications

The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above directive is indicated by CE mark on the device.

1.4 AUTHORIZED EUROPEAN REPRESENTATIVE

D R M Green European Compliance Services Limited. Avalon House, Marcham Road Abingdon, Oxon OX14 1UD, UK

1.5 SERVICE

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:

  • Tel: +1 (301) 975-1007
  • Email: support@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a>
  • URL: <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">http://www.patton.com</a>
Page 6 of the Patton electronic 2174 user manual — WARNING
Page 6 · click to enlarge
Page 6

1.6 SAFETY WHEN WORKING WITH ELECTRICITY

  • This device contains no user serviceable parts. This device can only be repaired by qualified service per sonnel.
  • Do not open the device when the power cord is con nected. For systems without a power switch and without an external power adapter, line voltages are present within the device when the power cord is connected.
  • For devices with an external power adapter, the power adapter shall be a listed Limited Power Source. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in com pliance with local regulatory requirements.
  • For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed.
  • For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground.

WARNING

  • For DC powered devices, ensure that the interconnect ing cables are rated for proper voltage, current, antici pated temperature, flammability, and mechanical serviceability.
  • WAN, LAN & PSTN ports (connections) may have haz ardous voltages present regardless of whether the device is powered ON or OFF. PSTN relates to inter faces such as telephone lines, FXS, FXO, DSL, xDSL, T1, E1, ISDN, Voice, etc. These are known as “hazard ous network voltages” and to avoid electric shock use caution when working near these ports. When discon necting cables for these ports, detach the far end con nection first.
  • Do not work on the device or connect or disconnect cables during periods of lightning activity.
Page 7 of the Patton electronic 2174 user manual — WARNING
Page 7 · click to enlarge
Page 7

In accordance with the requirements of council direc tive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you sepa rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy cling.

This device contains no user serviceable parts. This device can only be repaired by qualified service per sonnel.

WARNING

This device is NOT intended nor approved for connec tion to the PSTN. It is intended only for connection to customer premise equipment.

WARNING

Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Do the fol lowing to prevent ESD:

  • Always follow ESD prevention procedures when removing and replacing cards.
  • Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely chan nel unwanted ESD voltages to ground.

WARNING

  • To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
Page 8 of the Patton electronic 2174 user manual — 2.2 DESCRIPTION
Page 8 · click to enlarge
Page 8

2.0 GENERAL INFORMATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical Support at +1 (301) 975-1007.

2.1 FEATURES

  • Variable rate CopperLINK extender - Easy to configure
  • Auto-MDIX Ethernet
  • Configurable 10/100, Full/Half, and Auto-Negotiating Ethernet
  • Extends up to 4x 10/100Base-TX Ethernet beyond 328-foot (100meter) limitation over a single twisted-pair, Cat 5e/6/7, or coaxial cable
  • Symmetric or asymmetric settings via DIP switch
  • Transparent operation
  • LED indicators for Power, DSL Link, Ethernet Link/Activity, Remote and Local

2.2 DESCRIPTION

The Patton Electronics Model 2174 CopperLink modems provide high- speed LAN connections between peered Ethernet LANs, remote PCs, or any other network-enabled 10/100Base-T device.

Operating in pairs, one Model 2174 is configured as the (L) Local unit located at one end of the LAN extension and the other Model 2174 is con figured as the (R) Remote unit at the other end. The Model 2174 is config ured as a L or R via the switch on the bottom of the unit. These units can automatically forward LAN broadcasts, multicasts, and frames across a 2- wire voice-grade twisted-pair or BNC link. The data is passed transpar ently (unmodified) through the 2174s. The 2174s automatically add and delete MAC addresses, only passing packets across the CopperLINK link that are meant for the remote peered LAN.

Page 9 of the Patton electronic 2174 user manual — CAUTION
Page 9 · click to enlarge
Page 9
Patton electronic 2174 — 3.0 Installation diagram (page 9)
Fig. 3 · 3.0 Installation

Figure 1. Typical application

The pair of 2174 models work together to create a transparent extension between two peered Ethernet LANs using twisted pair (2-wire), Cat5+, or 75-ohm BNC. Figure 1 shows a typical point-to-point application.

3.0 INSTALLATION

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica- tion with respect to voltage, current, anticipated tem- perature, flammability, and mechanical serviceability.

CAUTION

To install the 2174 Ethernet Extender, do the following:

1. Connect the line interface between the units (refer to section 3.1,

“Connecting the Line Interface” on page 11)

2. Connect the Ethernet interface (refer to section 3.2, “Connecting the

10/100Base-T Ethernet Interface” on page 12).

3. Connect the power plug (refer to section 3.3, “Connecting Power” on

page 13).

Page 10 of the Patton electronic 2174 user manual — 3.0 Installation
Page 10 · click to enlarge
Page 10
Patton electronic 2174 — 3.0 Installation diagram (page 10)
Fig. 4 · 3.0 Installation

Figure 2. Model 2174 rear panel options

Page 11 of the Patton electronic 2174 user manual — 4 (RING)
Page 11 · click to enlarge
Page 11

3.1 CONNECTING THE LINE INTERFACE

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage, current, anticipated tem perature, flammability, and mechanical serviceability. CAUTION

The Model 2174 supports communication between two peer Ethernet LAN sites over a distance of up to 10,000 ft (3 km) over 24 AWG (0.5 mm) twisted-pair wire, Cat5+, or 75-ohm BNC.

Follow the steps below to connect the Model 2174 CopperLINK Inter faces.

Connecting the Line Interface for Model 2174/EUI or 2174/TB

1. To function properly, the two Model 2174s must be connected

together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.

2. The Model 2174 is equipped with an RJ-45 interface jack (Figure 3) or

terminal block (Figure 4) that can be used on the CopperLINK inter face. The CopperLINK interface is a two-wire interface. Observe the signal/pin relationships on the Model 2174's CopperLINK interface jack.

The RJ-45 connector on the Model 2174's twisted pair interface is polar ity insensitive and is wired for a two-wire interface. The signal/pin rela tionship is shown in Figure 3.

1 2 3 4 5 6 7 8

4 (RING)

5 (TIP)

Figure 3. Model 2174 (RJ-45) twisted pair line interfac.

Show 6 more labels / short text on this page
1 (no connection) · 2 (no connection) · 3 (no connection) · 6 (no connection) · 7 (no connection) · 8 (no connection)
Page 12 of the Patton electronic 2174 user manual — 3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE
Page 12 · click to enlarge
Page 12
Patton electronic 2174 — Connecting the Line Interface for Model 2174/BNC diagram (page 12)
Fig. 5 · Connecting the Line Interface for Model 2174/BNC

Figure 4. Model 2174 (Terminal Block) twisted pair line interface

Connecting the Line Interface for Model 2174/BNC

To connect the line interface of the Model 2174/BNC, simply use a coax ial cable with a BNC connector at each end to connect the pair of Model 2174s.

3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE

Patton electronic 2174 — 3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE diagram (page 12)
Fig. 6

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage, current, anticipated tem perature, flammability, and mechanical serviceability.

The RJ-45 ports labeled Ethernet are the Auto-MDIX10/100Base-T inter face. These ports are designed to connect directly to a 10/100Base-T device or network. Figure 5 shows the signal/pin relationships on this interface. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.

Patton electronic 2174 — 3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE diagram (page 12)
Fig. 7

Figure 5. Model 2174 10/100Base-T RJ-45 Connector Pinout.

Page 13 of the Patton electronic 2174 user manual — 4.1 CONFIGURING THE HARDWARE DIP SWITCHES
Page 13 · click to enlarge
Page 13

3.3 CONNECTING POWER

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage, current, anticipated tem perature, flammability, and mechanical serviceability. CAUTION

The Model 2174 does not have a power switch, so it powers up as soon as it is plugged in.

An external AC or DC power supply is available separately. This connec tion is made via the barrel jack on the rear panel of the Model 2174. No configuration is necessary for the power supply (See Appendix B for domestic and international power supply and cord options).

DC power (supplied via the power supply jack to the 2174) must meet the following requirements; DC power supplied must be regulated 12VDC ±5%, 1.0A minimum. Center pin is +12V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.

4.0 CONFIGURATION

The Model 2174 has eight DIP switches (S1) for configuring the unit for a wide variety of applications. This section describes switch locations and explains the different configurations.

4.1 CONFIGURING THE HARDWARE DIP SWITCHES

The DIP switches are externally accessible from the underside of the Model 2174. Figure 6 on page 14 shows the orientation of the DIP switches in the On and Off positions.

Page 14 of the Patton electronic 2174 user manual — 4.2 CONFIGURING DIP SWITCH S1
Page 14 · click to enlarge
Page 14
Patton electronic 2174 — 4.2 Configuring DIP Switch S1 diagram (page 14)
Fig. 8 · 4.2 Configuring DIP Switch S1

Figure 6. DIP switch orientation

4.2 CONFIGURING DIP SWITCH S1

DIP switch S1 is where you configure the CopperLINK line. The following tables describe the configuration for the 2174.

Table 1S1 Summary
Patton electronic 2174 — 4.2 CONFIGURING DIP SWITCH S1 diagram (page 14)
Fig. 9

S1-1 Local/Remote Configuration S1-2 Line Rate/Symmetry S1-3 Line Rate/Symmetry S1-4 Reserved S1-5 SNR Margin S1-6 Reserved S1-7 Reserved S1-8 Reserved

Page 15 of the Patton electronic 2174 user manual — Switch S1-1: Local/Remote Configuration
Page 15 · click to enlarge
Page 15
Switch S1-1Local/Remote Configuration

Use switch S1-1 to configure the unit as Remote or Local in the Model 2174 pair.

Table 2Local/Remote Unit Configuration

ON CPE/Remote OFF CO/Local

Switches S1-2 and S1-3Symmetric/Asymmetric Operation

Use switches S1-2 and S1-3 to configure the CopperLink line rate type and operation.

Table 3Symmetric/Asymmetric Selection Chart

OFF OFF High-Speed “Symmetric” OFF ON High-Speed “Asymmetric” ON OFF Long-Range “Symmetric” ON ON Long-Range “Asymmetric”

Switch S1-5General Protection (Signal to Noise Ratio)

Use switch S1-5 to configure line noise protection.

Table 4Signal to Noise Ratio

ON 6dB OFF 9dB

  • 6dB: Original line noise protection with 6dB SNR
  • 9dB: Better line noise protection with SNR up to 9dB

S1-1 Setting · S1-2 S1-3 Setting · S1-5 Setting

Page 16 of the Patton electronic 2174 user manual — 5.0 OPERATION
Page 16 · click to enlarge
Page 16

5.0 OPERATION

Once the Model 2174s are properly installed, they should operate trans parently. No user settings required. This section describes reading the LED status monitors.

Before applying power to the Model 2174, please review section 3.3, “Connecting Power” on page 13 to verify that the unit is connected to the appropriate power source.

Patton electronic 2174 — 5.0 OPERATION diagram (page 16)
Fig. 10

The Model 2174 features six front panel LEDs that monitor power, the Ethernet signals, the CopperLINK connection, and the remote/local set ting. Figure 7 shows the front panel location of each LED. Table 5 on page 16 describes the LED functions.

Figure 7. Model 2174 front panel

Table 5Front panel LED description
Patton electronic 2174 — 5.0 OPERATION diagram (page 16)
Fig. 11

Power Green The device is powered on. Off The device is powered off. CopperLink Green The port is connected. Blinking Green Data transceiving. Off No valid link on this port. Ethernet Green The port is connected.

Local Green The device acts in Local mode. Off Local mode is off. Remote Green The device acts in Remote mode. Off Remote mode is off.

*. Once the unit connects to a power source, the Link LED will blink as the 2174 automatically looks for the other unit in the pair.

Page 17 of the Patton electronic 2174 user manual — A.8 DIMENSIONS
Page 17 · click to enlarge
Page 17

APPENDIX A SPECIFICATIONS

A.1 LAN CONNECTION

  • Four RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
  • CopperLINK Connection: RJ-45

A.2 TRANSMISSION LINE

Two-wire unconditioned twisted pair or 75-ohm BNC

A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE

  • Line Rate: Up to 200 Mbps asymmetrical
  • Distance: Up to 9,842 ft (3 km)

A.4 LED STATUS INDICATORS

  • Power (Green)
  • CopperLINK: Link (Green)
  • Local (Green)
  • Remote (Green)
  • Ethernet: Link (Green) & Activity (Flashing Green)

A.5 POWER SUPPLY

External AC and DC options:

  • AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
  • DC: 12 VDC, 24 VDC and 48 VDC
  • Power consumption: 400mA at 12VDC

A.6 TEMPERATURE RANGE

0–50°C

A.7 HUMIDITY

Up to 90% non-condensing.

A.8 DIMENSIONS

1.5 H x 4.13 W x 3.75 D in. (38.1 H x 105 W x 95.3 D mm)

Page 18 of the Patton electronic 2174 user manual — Appendix B Model 2174 Series Factory Replacement Parts and Accessories
Page 18 · click to enlarge
Page 18

APPENDIX B MODEL 2174 SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES

Patton Model # Description

2174/EUI-2PK High Speed CopperLink Ethernet Extender Kit (Local and Remote); RJ45 Line, 100-240VAC

2174/TB/EUI-2PK High Speed CopperLink Ethernet Extender Kit (Local and Remote); Terminal Block Line, 100-240VAC

2174/BNC/EUI-2PK High Speed CopperLink Ethernet Extender Kit (Local and Remote); BNC Line, 100-240VAC 07M2174-UM User Manual Power Supplies

PS-03671H1-002 100-240VAC (12V, DC/2A) Wall mount power adapter Power Adapters

12-130 European replacement plug

12-129 American replacement plug

12-131 United Kingdom plug

Base Models · 12-132 Australian/Chinese plug

Page 19 of the Patton electronic 2174 user manual — C.2 COPPERLINK INTERFACE
Page 19 · click to enlarge
Page 19

APPENDIX C MODEL 2174 SERIES INTERFACE PIN ASSIGNMENT

C.1 10/100BASE-T INTERFACE

RJ-45

  • Pin 1: TX+
  • Pin 2: TX-
  • Pin 3: RX+
  • Pin 6: RX-
  • Pins 4, 5, 7, 8: no connection

C.2 COPPERLINK INTERFACE

RJ-45

  • Pin 4: RING
  • Pin 5: TIP
  • Pins 1, 2, 3, 6, 7, 8: no connection
Patton electronic 2174 — C.2 COPPERLINK INTERFACE diagram (page 19)
Fig. 12

Figure 1. Model 2174 (Terminal Block) twisted pair line interface

Page 20 of the Patton electronic 2174 user manual — APPENDIX D
Page 20 · click to enlarge
Page 20

APPENDIX D

LINE RATE & REACH CHART, BASED ON 24 AWG (0.5 MM)

Table 6Line Rate & Reach Chart Using Twisted-Pair (Long Range)

Distance in Feet Mbps

ft m/km DS US

250 ft 76 m 68 40 1000 ft 305 m 62 44 2,000 ft 610 m 50 16 3,000 ft 914 m 33 4 5,000 ft 1.5 km 16 2 10,000 ft 3 km 2.5 1

250 ft 76 m 67 16 1000 ft 305 m 59 16 2,000 ft 610 m 45 11 3,000 ft 914 m 31 5 5,000 ft 1.5 km 17 682 kbps 10,000 ft 3 km 4 263 kbps

Mode (Long Range) · Symmetric · Asymmetric

Page 21 of the Patton electronic 2174 user manual — Appendix D Line Rate & Reach Chart, Based on 24 AWG (0.5 MM)
Page 21 · click to enlarge
Page 21
Table 7Line Rate & Reach Chart Using Twisted-Pair (High Speed)

Distance in Feet Mbps

ft m/km DS US

250 ft 76 m 121 144 1000 ft 305 m 73 103 2,000 ft 610 m 45 37 3,000 ft 914 m 46 10 3,500 ft 1 km 30 4

250 ft 76 m 168 95 1000 ft 305 m 126 54 2,000 ft 610 m 60 21 3,000 ft 914 m 42 6 3,500 ft 1 km 35 1

Mode (High Speed) · Symmetric · Asymmetric

Page 22 of the Patton electronic 2174 user manual — NOTES
Page 22 · click to enlarge
Page 22

NOTES

Show 14 more labels / short text on this page
_________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________
Page 23 of the Patton electronic 2174 user manual — NOTES
Page 23 · click to enlarge
Page 23

NOTES

Show 14 more labels / short text on this page
_________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________ · _________________________________________________________
Page 24 of the Patton electronic 2174 user manual — Appendix D Line Rate & Reach Chart, Based on 24 AWG (0.5 MM)
Page 24 · click to enlarge
Page 24

Copyright © 2011. Patton Electronics Company

All Rights Reserved.

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 2174

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 2174

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 2174 manual PDF

24 pages·532 KB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…