MODEL 2174 CopperLINK™ High Speed Ethernet Extender

This is a Class A device and is not intended for use in a residential environment.

Part# 07M2174-UM Rev. A Revised 9/23/11
An ISO-9001Certified · Company

1.0 Warranty Information 4 1.1 Regulatory Information 4
EMC Directive: 4 Low-Voltage Direcive (Safety): 4 PSTN: 4 1.2 Radio and TV Interference (FCC Part 15) 4 1.3 CE Declaration of Conformity 5 1.4 Authorized European Representative 5 1.5 Service 5 1.6 Safety When Working With Electricity 6
2.0 General Information 8 2.1 Features 8 2.2 Description 8
3.0 Installation 9 3.1 Connecting the Line Interface 11
Connecting the Line Interface for Model 2174/EUI or 2174/TB.. 11 Connecting the Line Interface for Model 2174/BNC 12 3.2 Connecting the 10/100Base-T Ethernet Interface 12 3.3 Connecting Power 13
4.0 Configuration 13 4.1 Configuring the Hardware DIP switches 13 4.2 Configuring DIP Switch S1 14
Switch S1-1: Local/Remote Configuration 15 Switches S1-2 and S1-3: Symmetric/Asymmetric Operation 15 Switch S1-5: General Protection (Signal to Noise Ratio) 15
5.0 Operation 16 5.1 Front Panel LED Status Monitors 16
A Specifications 17 A.1 LAN Connection 17 A.2 Transmission Line 17 A.3 CopperLINK Line Rate and CopperLINK Distance 17 A.4 LED Status Indicators 17 A.5 Power Supply 17 A.6 Temperature Range 17 A.7 Humidity 17 A.8 Dimensions 17
B Model 2174 Series Factory Replacement Parts and Accessories 18
C Model 2174 Series Interface Pin Assignment 19 C.1 10/100Base-T Interface 19


Patton Electronics warrants all Model 2174 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not performs as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics spe cifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
EMC Directive:
Low-Voltage Direcive (Safety):
This device generates and uses radio frequency energy, and if not installed and used properly-that is, in strict accordance with the manufac turer’s instructions-may cause interference to radio and television recep

tion. The device has been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable pro tection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular instal lation. If the device does cause interference to radio or television recep tion, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the follow ing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equip ment into a different AC outlet (such that the computing equipment and receiver are on different branches).
Patton Electronics, Inc declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2004/108/EC relating to electromagnetic compatibility and Directive 2006/95/EC relating to electrical equipment designed for use within cer tain voltage limits. The Declaration of Conformity may be obtained from Patton Electronics, Inc at www.patton.com/certifications
The safety advice in the documentation accompanying this device shall be obeyed. The conformity to the above directive is indicated by CE mark on the device.
D R M Green European Compliance Services Limited. Avalon House, Marcham Road Abingdon, Oxon OX14 1UD, UK
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:


In accordance with the requirements of council direc tive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you sepa rate this product from other waste and scrap and deliver to the WEEE collection system in your country for recy cling.
This device contains no user serviceable parts. This device can only be repaired by qualified service per sonnel.
This device is NOT intended nor approved for connec tion to the PSTN. It is intended only for connection to customer premise equipment.
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Do the fol lowing to prevent ESD:

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical Support at +1 (301) 975-1007.
The Patton Electronics Model 2174 CopperLink modems provide high- speed LAN connections between peered Ethernet LANs, remote PCs, or any other network-enabled 10/100Base-T device.
Operating in pairs, one Model 2174 is configured as the (L) Local unit located at one end of the LAN extension and the other Model 2174 is con figured as the (R) Remote unit at the other end. The Model 2174 is config ured as a L or R via the switch on the bottom of the unit. These units can automatically forward LAN broadcasts, multicasts, and frames across a 2- wire voice-grade twisted-pair or BNC link. The data is passed transpar ently (unmodified) through the 2174s. The 2174s automatically add and delete MAC addresses, only passing packets across the CopperLINK link that are meant for the remote peered LAN.


Figure 1. Typical application
The pair of 2174 models work together to create a transparent extension between two peered Ethernet LANs using twisted pair (2-wire), Cat5+, or 75-ohm BNC. Figure 1 shows a typical point-to-point application.
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica- tion with respect to voltage, current, anticipated tem- perature, flammability, and mechanical serviceability.
To install the 2174 Ethernet Extender, do the following:
“Connecting the Line Interface” on page 11)
10/100Base-T Ethernet Interface” on page 12).
page 13).


Figure 2. Model 2174 rear panel options

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage, current, anticipated tem perature, flammability, and mechanical serviceability. CAUTION
The Model 2174 supports communication between two peer Ethernet LAN sites over a distance of up to 10,000 ft (3 km) over 24 AWG (0.5 mm) twisted-pair wire, Cat5+, or 75-ohm BNC.
Follow the steps below to connect the Model 2174 CopperLINK Inter faces.
Connecting the Line Interface for Model 2174/EUI or 2174/TB
together using twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
terminal block (Figure 4) that can be used on the CopperLINK inter face. The CopperLINK interface is a two-wire interface. Observe the signal/pin relationships on the Model 2174's CopperLINK interface jack.
The RJ-45 connector on the Model 2174's twisted pair interface is polar ity insensitive and is wired for a two-wire interface. The signal/pin rela tionship is shown in Figure 3.
1 2 3 4 5 6 7 8
5 (TIP)
Figure 3. Model 2174 (RJ-45) twisted pair line interfac.


Figure 4. Model 2174 (Terminal Block) twisted pair line interface
Connecting the Line Interface for Model 2174/BNC
To connect the line interface of the Model 2174/BNC, simply use a coax ial cable with a BNC connector at each end to connect the pair of Model 2174s.

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage, current, anticipated tem perature, flammability, and mechanical serviceability.
The RJ-45 ports labeled Ethernet are the Auto-MDIX10/100Base-T inter face. These ports are designed to connect directly to a 10/100Base-T device or network. Figure 5 shows the signal/pin relationships on this interface. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.

Figure 5. Model 2174 10/100Base-T RJ-45 Connector Pinout.

The Interconnecting cables shall be acceptable for external use and shall be rated for the proper applica tion with respect to voltage, current, anticipated tem perature, flammability, and mechanical serviceability. CAUTION
The Model 2174 does not have a power switch, so it powers up as soon as it is plugged in.
An external AC or DC power supply is available separately. This connec tion is made via the barrel jack on the rear panel of the Model 2174. No configuration is necessary for the power supply (See Appendix B for domestic and international power supply and cord options).
DC power (supplied via the power supply jack to the 2174) must meet the following requirements; DC power supplied must be regulated 12VDC ±5%, 1.0A minimum. Center pin is +12V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.
The Model 2174 has eight DIP switches (S1) for configuring the unit for a wide variety of applications. This section describes switch locations and explains the different configurations.
The DIP switches are externally accessible from the underside of the Model 2174. Figure 6 on page 14 shows the orientation of the DIP switches in the On and Off positions.


Figure 6. DIP switch orientation
DIP switch S1 is where you configure the CopperLINK line. The following tables describe the configuration for the 2174.

S1-1 Local/Remote Configuration S1-2 Line Rate/Symmetry S1-3 Line Rate/Symmetry S1-4 Reserved S1-5 SNR Margin S1-6 Reserved S1-7 Reserved S1-8 Reserved

Use switch S1-1 to configure the unit as Remote or Local in the Model 2174 pair.
ON CPE/Remote OFF CO/Local
Use switches S1-2 and S1-3 to configure the CopperLink line rate type and operation.
OFF OFF High-Speed “Symmetric” OFF ON High-Speed “Asymmetric” ON OFF Long-Range “Symmetric” ON ON Long-Range “Asymmetric”
Use switch S1-5 to configure line noise protection.
ON 6dB OFF 9dB
S1-1 Setting · S1-2 S1-3 Setting · S1-5 Setting

Once the Model 2174s are properly installed, they should operate trans parently. No user settings required. This section describes reading the LED status monitors.
Before applying power to the Model 2174, please review section 3.3, “Connecting Power” on page 13 to verify that the unit is connected to the appropriate power source.

The Model 2174 features six front panel LEDs that monitor power, the Ethernet signals, the CopperLINK connection, and the remote/local set ting. Figure 7 shows the front panel location of each LED. Table 5 on page 16 describes the LED functions.
Figure 7. Model 2174 front panel

Power Green The device is powered on. Off The device is powered off. CopperLink Green The port is connected. Blinking Green Data transceiving. Off No valid link on this port. Ethernet Green The port is connected.
Local Green The device acts in Local mode. Off Local mode is off. Remote Green The device acts in Remote mode. Off Remote mode is off.
*. Once the unit connects to a power source, the Link LED will blink as the 2174 automatically looks for the other unit in the pair.

A.1 LAN CONNECTION
Two-wire unconditioned twisted pair or 75-ohm BNC
External AC and DC options:
0–50°C
A.7 HUMIDITY
Up to 90% non-condensing.
1.5 H x 4.13 W x 3.75 D in. (38.1 H x 105 W x 95.3 D mm)

APPENDIX B MODEL 2174 SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES
Patton Model # Description
2174/EUI-2PK High Speed CopperLink Ethernet Extender Kit (Local and Remote); RJ45 Line, 100-240VAC
2174/TB/EUI-2PK High Speed CopperLink Ethernet Extender Kit (Local and Remote); Terminal Block Line, 100-240VAC
2174/BNC/EUI-2PK High Speed CopperLink Ethernet Extender Kit (Local and Remote); BNC Line, 100-240VAC 07M2174-UM User Manual Power Supplies
PS-03671H1-002 100-240VAC (12V, DC/2A) Wall mount power adapter Power Adapters
12-130 European replacement plug
12-129 American replacement plug
12-131 United Kingdom plug
Base Models · 12-132 Australian/Chinese plug

C.1 10/100BASE-T INTERFACE
RJ-45
RJ-45

Figure 1. Model 2174 (Terminal Block) twisted pair line interface

LINE RATE & REACH CHART, BASED ON 24 AWG (0.5 MM)
Distance in Feet Mbps
ft m/km DS US
250 ft 76 m 68 40 1000 ft 305 m 62 44 2,000 ft 610 m 50 16 3,000 ft 914 m 33 4 5,000 ft 1.5 km 16 2 10,000 ft 3 km 2.5 1
250 ft 76 m 67 16 1000 ft 305 m 59 16 2,000 ft 610 m 45 11 3,000 ft 914 m 31 5 5,000 ft 1.5 km 17 682 kbps 10,000 ft 3 km 4 263 kbps
Mode (Long Range) · Symmetric · Asymmetric

Distance in Feet Mbps
ft m/km DS US
250 ft 76 m 121 144 1000 ft 305 m 73 103 2,000 ft 610 m 45 37 3,000 ft 914 m 46 10 3,500 ft 1 km 30 4
250 ft 76 m 168 95 1000 ft 305 m 126 54 2,000 ft 610 m 60 21 3,000 ft 914 m 42 6 3,500 ft 1 km 35 1
Mode (High Speed) · Symmetric · Asymmetric