User Manual

For Quick · Start Installation

Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
Trademark Statement The term CopperLink is a trademark of Patton Electronics Company. All other trade- marks presented in this document are the property of their respective owners.
Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.
Warranty Information Patton Electronics warrants all Model 2160 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warran- ties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1 General information 17
2 Applications overview 22
3 Hardware installation 27
4 Web configuration 33
5 Console and Telnet configuration 69
6 Contacting Patton for assistance 103
A Compliance information 106
B Specifications 108
C Port pin-outs 111


1 Model 2160 18 2 Model 2160 front panel LEDs 19 3 Model 2160 rear panel 20 4 Model 2160 application 23 5 Model 2160 connection diagram 29 6 Grounding stud 31 7 System login screen 36 8 Basic setup flowchart 36 9 Operation mode and Management port setup page 37 10 Basic DHCP setup 38 11 LAN setup page 39 12 Review and save basic setup changes 40 13 LINE page 41 14 VLAN page 43 15 VLAN Diagram 44 16 802.1Q Tag-Based VLAN page 45 17 VLAN tag field 46 18 802.1Q VLAN diagram 47 19 Port-Based VLAN page 48 20 QoS page 49 21 QoS - Port Based Priority page 50 22 WRR Example 51 23 WFQ Example 51 24 BE Example 51 25 SP Example 52 26 QoS - Port Based Priority - WRR Configuration 52 27 QoS - Port Based Priority - WFQ Configuration 52 28 QoS - Port Based Priority Table 52 29 QoS - VLAN Tag Priority page 53 30 IEEE 802.1Q Tagged Frame for Ethernet 53 31 QoS - Tag Based Priority - WRR Configuration 54 32 QoS - Tag Based Priority - WFQ Configuration 54 33 QoS - VLAN Tag Priority Table 55 34 Service by WRR 56 35 DSCP field 56 36 QoS - IP DSCP Priority - WRR Configuration 57 37 QoS - IP DSCP Priority - WFQ Configuration 57 38 QoS - IP DSCP Priority page 58 39 DSCP Configuration Example 58 40 Rate Limit page 59 41 Flow Control page 59 42 LINE Status page (8-wire model shown) 60 43 Management Status page 60 44 LAN Status page 61 45 Performance Status page 61 46 Security Administration page 62 47 Model 2160 configuration modes 62

Model 2160 Series User Manual
48 Remote Management Host section 63 49 SNMP Administration page 64 50 SNMP community pool configuration 64 51 Trap host pool configuration 65 52 Remote Syslog configuration page 65 53 System Information page 66 54 Configuration Tool page 66 55 Upgrade page 67 56 Logout page 68 57 Restart page 68 58 Restart page 68 59 Console/Telnet Menu 72 60 Menu tree for authorized users 73 61 Main screen for authorized users 74 62 Main menu for unauthorized users 74 63 Main screen for unauthorized users 74 64 LINE Status 90 65 Interface Status 91 66 System Information 92 67 Show Script 92 68 EIA-561 (RJ-45 8-pin) port 112

1 General conventions 16 2 Front panel LEDs 19 3 Port descriptions 20 4 Distance Chart 2160 Series – Auto Mode 24 5 Distance Chart Model 2160 Series – Optimal Mode 25 6 Distance Chart Model 2160 Series – TCPAM-128 26 7 Line Type Chart 41 8 Main Rate Chart 42 9 VLAN Tag Priority Levels 54 10 WRR Scheduling Configuration Example Values 55 11 Default SNMP Communities 64 12 Console settings 71 13 Interface commands 71 14 Enable Command Menu 75 15 Line Options 76 16 Line Type Chart 77 17 Main Rate Table 77 18 LAN Options 78 19 VLAN Mode Options 79 20 802.1Q VLAN Options 81 21 VLAN Mode Options 82 22 Queue Schedule Types 82 23 Queue Schedule Options 83 24 Egress Rate (N Value) 84 25 Port-Based Priority QoS Options 84 26 VLAN Tag Priority Levels 85 27 VLAN Tag Priority QoS Options 85 28 Rate Options 86 29 IP DSCP Priority QoS Options 86 30 DHCP Command Descriptions 88 31 Status Command Menu 90 32 Interface Statistics 91 33 Show Command Menu 92 34 RJ45 socket 10/100Base-T 113 35 RJ45 socket CopperLink 113

This guide describes the CopperLink™ Model 2160 hardware, installation and basic configuration.
This guide is intended for the following users:
This guide contains the following chapters and appendices:
For best results, read the contents of this guide before you install the Model 2160.

Model 2160 Series User Manual About this guide
The alert symbol and IMPORTANT heading calls attention to important information.
The alert symbol and CAUTION heading indicate a potential hazard. Strictly follow the instructions to avoid property damage.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.

Model 2160 Series User Manual About this guide
The Model 2160 contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service per- sonnel. Opening the Model 2160 case will void the warranty.
Mains Voltage: Do not open the case the when the power cord is attached. Line voltages are present within the power supply when the power cords are connected. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and pro- tected by a circuit breaker.
For AC powered units, ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
Hazardous network voltages are present in WAN ports regardless of whether power to the Model 2160 is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the Model 2160 first.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.

Model 2160 Series User Manual About this guide
Preventing Electrostatic Discharge Damage When starting to install interface cards place the interface card on its shielded plastic bag if you lay it on your bench.
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures.
Always follow ESD prevention procedures when removing and replacing cards.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.
To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is avail- able, ground yourself by touching the metal part of the chassis.
General observations • Clean the case with a soft slightly moist anti-static cloth

Model 2160 Series User Manual About this guide
This section describes the typographical conventions and terms used in this guide.
General conventions The procedures described in this manual use the following text conventions:
Table 1. General conventions
Garamond blue type Indicates a cross-reference hyperlink that points to a figure, graphic, table, or sec- tion heading. Clicking on the hyperlink jumps you to the reference. When you have finished reviewing the reference, click on the Go to Previous View
button in the Adobe® Acrobat® Reader toolbar to return to your starting point.
Futura bold type Commands and keywords are in boldface font.
Futura bold-italic type Parts of commands, which are related to elements already named by the user, are in boldface italic font.
Italicized Futura type Variables for which you supply values are in italic font Futura type Indicates the names of fields or windows.
Garamond bold type Indicates the names of command buttons that execute an action. < > Angle brackets indicate function and keyboard keys, such as , , , and so on.
[ ] Elements in square brackets are optional.
{a | b | c} Alternative but required keywords are grouped in braces ({ }) and are separated by vertical bars ( | )
blue screen Information you enter is in blue screen font.
screen Terminal sessions and information the system displays are in screen font.
node The leading IP address or nodename of a Model 2160 is substituted with node in boldface italic font.
# An hash sign at the beginning of a line indicates a comment line.
Convention Meaning


Model 2160 Series User Manual 1 • General information
The Patton CopperLink™ Model 2160 simplifies and provides cost effective network extension by utilizing pre-existing twisted pair infrastructure enables service providers to offer broadband or data backhaul services to businesses, governments, and various institutions over existing last-mile, copper infrastructure. Today, more than ever, operators are finding the business case for leveraging their existing copper networks to be highly attractive from an ROI and initial investment perspective over fiber roll-outs.
Patton’s 2160 CopperLink Ethernet Extender incorporates multi-pair bonding to offer unmatched rate, reach and reliable Ethernet connectivity, providing symmetrical 22.8 Mbps of bandwidth over 4-pair (8-wire) at dis- tances up to 1.8 miles (2.9 km). The Model 2160 comes standard with a 4-port fast Ethernet switch with full QoS and CoS features. VLAN (802.1q) capabilities include 4 levels of priorities, traffic flow control, and rate control. These traffic management and QoS features enable service providers to provision for differentiated ser- vices and/or SLAs.

Figure 1. Model 2160
The following base models are available:
Refer to Appendix B, “Specifications” on page 108 for a complete feature description of the Model 2160.
Model 2160 overview 18

Model 2160 Series User Manual 1 • General information
LED descriptions The front panel LEDs display the status of the power, system, Ethernet ports, and Line port. Figure 2 shows the front panel LED indicators and table 2 provides a description of the LED indicators’ behavior.

LINK 1 2 3 4 CopperLink™ 2160 Long Range Ethernet Extender
WAN(1-4) Line Connection LAN (1-4) Ethernet Link/Activity LAN (1-4) Ethernet Mode
Figure 2. Model 2160 front panel LEDs
Table 2. Front panel LEDs

LAN port is on 100M mode LAN port is on 10M mode
Model 2160 front panel 19

Model 2160 Series User Manual 1 • General information

Port descriptions The CopperLink™ Model 2160 rear panel ports are shown in figure 3 and described in table 3.
Figure 3. Model 2160 rear panel
Table 3. Port descriptions

Console (RS-232 control port) Used for service and maintenance, the Console port, an RS-232 RJ-45 connector with EIA-561 pinout, connects the router to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal). Asynchronous default data rate 9600 bps, hardware DSR and DTR signals for external modems are wired directly together internally
Reset Reset button for rebooting or loading factory default settings
LAN (LAN Ethernet Ports 1-4) 10/100Base-Tx full-/half-duplex, RJ-45, auto detection and fall- back, connects the unit to an Ethernet LAN.
Model 2160 rear panel 20

Model 2160 Series User Manual 1 • General information
Reset button • To restart the unit with the current startup configuration—Press for less than 1 second and release the Reset button. The Model 2160 will restart with the current startup configuration.
The marked lug or terminal should be connected to the building protective earth bus.The func- tion of protective earth does not serve the purpose of providing protection against electrical shock, but instead enhances surge suppression on the lines for installations where suitable bonding facili- ties exist.The connector type is M3 machine screw.
Model 2160 rear panel 21


Model 2160 Series User Manual 2 • Applications overview
The Patton CopperLink™ Model 2160 simplifies and provides cost effective network extension by utilizing pre-existing twisted pair infrastructure enables service providers to offer broadband or data backhaul services to businesses, governments, and various institutions over existing last-mile, copper infrastructure. Today, more than ever, operators are finding the business case for leveraging their existing copper networks to be highly attractive from an ROI and initial investment perspective over fiber roll-outs.
Patton’s CopperLink Auto-Rate Ethernet Extenders are the perfect fit for simple, cost-effective high speed Ethernet Extension. They allow customers to take advantage of the existing copper infrastructure to connect remote LAN’s across distances and at speeds previously unthought-of. The auto-rate feature ensures the highest speed is achieved on each connection, and the plug-n-play operation ensures they are up and running in sec- onds. Add in the 4 x auto-sensing full/half duplex 10/100Base-TX Ethernet ports with the integrated crossover switch to make setup even easier. The value of these Ethernet Extenders can’t be beat!

Figure 4. Model 2160 application
Introduction 23

Model 2160 Series User Manual 2 • Applications overview
Table 4. Distance Chart 2160 Series – Auto Mode

2160 2-Wire 2161 4-Wire 2162 8-Wire 26 AWG/0.4mm 24 AWG/0.5mm 22 AWG/0.65mm
N = kbps kbps kbps kft km kft km kft km
3 192 384 768 17.0 5.2 21.5 6.6 27.5 8.4
4 256 512 1024 17.0 5.2 20.5 6.2 27.0 8.2
8 512 1024 2048 14.5 4.4 17.5 5.3 23.5 7.2
12 768 1536 3072 13.5 4.1 16.0 4.9 21.5 6.6
16 1024 2048 4096 12.5 3.8 15.0 4.6 20.0 6.1
20 1280 2560 5120 12.0 3.7 14.5 4.4 19.0 5.8
24 1536 3072 6144 11.5 3.5 14.0 4.3 18.5 5.6
32 2048 4096 8192 11.0 3.4 13.5 4.1 17.5 5.3
36 2304 4608 9216 11.0 3.4 13.0 4.0 17.0 5.2
60 3840 7680 15360 9.0 2.7 11.0 3.4 14.5 4.4
72 4608 9216 18432 8.5 2.6 10.0 3.0 13.5 4.1
89 5696 11392 22784 7.5 2.3 9.0 2.7 12.0 3.7
Distance charts 24

Model 2160 Series User Manual 2 • Applications overview
Table 5. Distance Chart Model 2160 Series – Optimal Mode

2160 2-Wire 2161 4-Wire 2162 8-Wire 26 AWG/0.4mm 24 AWG/0.5mm 22 AWG/0.65mm
N = kbps kbps kbps kft km kft km kft km
7 448 896 1792 20.0 6.1 24.0 7.3 31.0 9.4
8 512 1024 2048 19.0 5.8 23.0 7.0 30.0 9.1
10 640 1280 2560 18.0 5.5 20.5 6.2 28.0 8.5
11 704 1408 2816 17.0 5.2 19.0 5.8 26.5 8.1
16 1024 2048 4096 16.0 4.9 18.0 5.5 24.5 7.5
20 1280 2560 5120 15.0 4.6 17.0 5.2 23.0 7.0
22 1408 2816 5632 14.0 4.3 15.5 4.7 21.0 6.4
27 1728 3456 6912 13.0 4.0 14.5 4.4 20.0 6.1
34 2176 4352 8704 12.0 3.7 14.5 4.4 18.5 5.6
39 2496 4992 9987 11.0 3.4 13.0 4.0 17.0 5.2
44 2816 5362 11264 10.0 3.0 12.0 3.7 15.5 4.7
53 3392 6784 13568 9.0 2.7 10.5 3.2 13.5 4.1
73 4672 9344 18688 8.0 2.4 9.5 2.9 12.5 3.8
89 5696 11392 22784 7.0 2.1 8.5 2.6 10.5 3.2
110 7040 14080 28160 6.0 1.8 7.0 2.1 9.0 2.7
125 8000 16000 32000 5.0 1.5 6.0 1.8 7.5 2.3
152 9728 19456 38912 4.0 1.2 4.5 1.4 6.0 1.8
164 10496 20992 41984 3.0 0.9 3.5 1.1 4.5 1.4
198 12792 25584 51168 2.0 0.6 2.5 0.8 3.0 0.9
Distance charts 25

Model 2160 Series User Manual 2 • Applications overview
Table 6. Distance Chart Model 2160 Series – TCPAM-128

2160 2-Wire 2161 4-Wire 2162 8-Wire 26 AWG/0.4mm 24 AWG/0.5mm 22 AWG/0.65mm
N = kbps kbps kbps kft km kft km kft km
5 320 640 1280 22.0 6.7 26.5 8.1 34 10.4
6 384 768 1536 21.0 6.4 25.5 7.8 32.5 9.9
8 512 1024 2048 20.0 6.1 24.0 7.3 31.0 9.4
9 576 1152 2304 19.0 5.8 23.0 7.0 29.5 9.0
9 576 1152 2304 18.0 5.5 21.5 6.6 27.5 8.4
12 768 1536 3072 17.0 5.2 20.5 6.2 26.5 8.1
16 1024 2048 4096 16.0 4.9 19.5 5.9 24.5 7.5
20 1280 2560 5120 15.0 4.6 18.0 5.5 23.0 7.0
22 1408 2816 5632 14.0 4.3 16.5 5.0 21.5 6.6
27 1728 3456 6912 13.0 4.0 15.7 4.8 20.0 6.1
34 2176 4352 8704 12.0 3.7 14.5 4.4 18.5 5.6
39 2496 4992 9984 11.0 3.4 13.0 4.0 17.0 5.2
45 2880 5760 11520 10.0 3.0 12.0 3.7 15.5 4.7
53 3392 6784 13568 9.0 2.7 10.5 3.2 13.5 4.1
74 4736 9472 18944 8.0 2.4 9.5 2.9 12.5 3.8
90 5760 11520 23040 7.0 2.1 8.5 2.6 10.5 3.2
112 7168 14336 28672 6.0 1.8 7.0 2.1 9.0 2.7
126 8064 16128 32256 5.0 1.5 6.0 1.8 7.5 2.3
152 9728 19456 38912 4.0 1.2 4.5 1.4 6.0 1.8
167 10688 21376 42752 3.0 0.9 3.5 1.1 4.5 1.4
198 12672 25344 50688 2.0 0.6 2.5 0.8 3.0 0.9
220 14072 28144 56288 1.0 0.3 1.0 0.3 1.5 0.5
239 15288 30576 61152 0.5 0.2 0.5 0.2 1.0 0.3
Distance charts 26


Model 2160 Series User Manual 3 • Hardware installation
This chapter contains information for planning the installation of the Model 2160 with the following installa- tion procedures:
Before beginning the actual installation, we strongly recommend that you gather all the information you will need to install and set up the device.
When you finish preparing for your installation, go to section “Installing the Model 2160” on page 30 to install the device.
Introduction 28

Model 2160 Series User Manual 3 • Hardware installation
Network diagram Draw a network overview diagram that displays all neighboring IP nodes, connected elements and telephony components. Figure 5 shows possible network connections to the Model 2160.

Figure 5. Model 2160 connection diagram
IP related information Before you can set up the basic IP connectivity for your Model 2160 series you should have the following information:
You will need a PC (or equivalent) with a VT-100 emulation program (e.g. HyperTerminal) to configure the software on your Model 2160.
AC Power Mains If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery with large motors nearby, have a qualified professional test the power. Install a power conditioner if necessary. Refer to “Grounding the Model 2160 and connecting power” on page 31.

The mains outlet that is utilized to power the equipment must be within 1 foot (3 meters) of the device and shall be easily accessible.
Planning the installation 29

Model 2160 Series User Manual 3 • Hardware installation
Location and mounting requirements The Model 2160 is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables. Additionally, you should consider the need to access the unit for future upgrades and maintenance.
This completes the planning phase for installation. The next section begins the installation procedures.
Unpacking the Model 2160 Inspect the shipping carton for external damage. Note any damage before removing the container contents. Report any equipment damage to the shipping carrier immediately for claim purposes. Save all packing mate- rial in case you need to return an item to the factory for servicing.
The Model 2160 comes with the following items:
The Interconnecting cables must be acceptable for external use and must be rated for the proper application with respect to volt- age, current, anticipated temperature, flammability, and mechanical serviceability.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Installing the Model 2160 30

Model 2160 Series User Manual 3 • Hardware installation
Grounding the Model 2160 and connecting power In connecting to the power source, it is important to establish a good grounding connection first, then the power connection. Do the following:
– The building ground rod (generally located at the site’s main service entrance)
– A sprinkler system pipe
– A cold-water pipe
– Building structural steel
Figure 6. Grounding stud
Mains Voltage: Do not open the case the when the power cord is attached. Line voltages are present within the power supply when the power cords are connected. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and pro- tected by a circuit breaker.
The Model 2160 is not shipped with power cables. For AC powered units, ensure that the power cable used meets all applicable standards for the coun- try in which it is to be installed, and that it is connected to a wall outlet which has earth ground.
The power supply automatically adjusts to accept an input volt- age from 100 to 240 VAC(50/60 Hz).
Installing the Model 2160 31
Grounding stud

Model 2160 Series User Manual 3 • Hardware installation
There are three different ways you can configure the Model 2160: the serial console, Telnet, or a web browser.
Web configuration requirements Make sure that the PC you use for configuration has an Ethernet adapter and TCP/IP installed.
The Model 2160 provides a browser interface that allows you to configure and manage the Ethernet Extender. After you set up the IP address for the 2160, you can access the Ethernet Extender's Web interface applications directly in your browser by entering the IP address. You can then use your Web browser to manage and config- ure the unit from a PC.
Console configuration requirements To configure the Model 2160 through the serial console, you can directly connect a terminal or a PC equipped with a terminal-emulation program (such as Hyper Terminal) to the Ethernet Extender's console port.
Use the supplied serial cable (RJ-45 to DB9F) to connect the Model 2160 to a PC. After marking the connec- tion, configure the terminal-emulation program to use the following parameters:
Telnet configuration requirements Make sure that the PC you use for configuration has an Ethernet adapter and TCP/IP installed. The Model 2160 supports Telnet for remote configuration. The command is “telnet 192.168.1.1” . When prompted for the username and password for remote login, use admin for username and admin for password. All display screens are the same as serial console configuration.
The default IP address is 192.168.1.1, but you may change the IP address for your application.
Configuring the Model 2160 32



The Model 2160 provides a browser interface that allows you to configure and manage the Ethernet Extender. Make sure that the PC you use for configuration has an Ethernet adapter and TCP/IP installed. After you set up the IP address for the 2160, you can access the Ethernet Extender's Web interface applications directly in your browser by entering the IP address. You can then use your Web browser to manage and configure the unit from a PC.
This section introduces the configuration and functions of the Web Management Interface (WMI). The WMI is an HTML-based management interface that allows you to easily set-up and manage the Model 2160.
The Model 2160 offers all monitoring and management features that allow users to manage this Model 2160 form anywhere on the network through a standard browser such as Internet Explorer.
TCP/IP setup When DHCP is enabled, the Model 2160 acts as a DHCP server in your network. The Model 2160 will auto- matically assign IP address for the management port connection.
To set up TCP/IP on a Windows PC:
System Login You may use a web browser such as Internet Explorer on your PC to connect the Model 2160. Type “http://” and the IP address like as “http://192.168.1.1”.
The default IP address and sub net-mask of the Management port of the Model 2160 are 192.168.1.1 and 255.255.255.0. If DHCP is disabled, your PC can set the same net-mask such as 192.168.1.x where x is a number from 2 to 254.
Introduction 35

Type the default User name root and default Password root and then click OK. For system security, you should change the user name and password after initial onfiguration.

Figure 7. System login screen
This section contains information for setting up the operation mode and Management port IP, DHCP server, and LAN via the WMI. Figure 8 shows a flowchart demonstrating basic setup via the WMI for the Model 2160.

Figure 8. Basic setup flowchart
Basic Configuration Options 36

Operation mode and Management port To configure the operation mode and Management port in the WMI:

Figure 9. Operation mode and Management port setup page
Some ISP providers require the Host Name as identification. You may check with your ISP to see if your Internet service has been configured with a host name. In most cases, you can ignore this field.
DHCP server Dynamic Host Configuration Protocol (DHCP) is a communication protocol that allows network adminis- trators to manage and automate the assignment of Internet Protocol (IP) addresses in an organization's net- work. Each machine that can connect to the Internet needs a unique IP address. When an organization sets up the users with a connection to the Internet, an IP address must be assigned to each machine.
Without DHCP, the IP address must be entered manually at each computer. If computers move to another location in another part of the network, a new IP address must be entered. DHCP lets a network administrator
Basic Configuration Options 37

supervise and distribute IP addresses from a central point and automatically sends a new IP address when a computer is plugged into a different place in the network. The embedded DHCP server assigns network con- figuration information to 253 users (max) accessing the Internet in the same time. For example, if the LAN IP address is 192.168.0.1, the IP range of the LAN is 192.168.0.2 to 192.168.0.254.
To set up the DHCP Server for the Model 2160:

Figure 10. Basic DHCP setup
Basic Configuration Options 38

LAN To configure LAN settings through the WMI:

Figure 11. LAN setup page
Basic Configuration Options 39

Review and save basic setup changes 1. Once you have entered information on the pages for Operation Mode and Management Port, DHCP Server, and LAN, the Basic Setup Review page will display to confirm your changes.

Figure 12. Review and save basic setup changes
Basic Configuration Options 40

This section contains information for setting up advanced options for the Model 2160 via the WMI. Advanced setup contains Model 2160 Line, VLAN, QoS and Rate Control parameters.
LINE Click on LINE under Advanced on the main menu to reach the LINE advanced configuration page. You can setup the Line Type (number of wires), Annex Type, TCPAM Type, Main Rate, SNR Margin, and Line Probe settings for LINE parameters.

Figure 13. LINE page
Line Type Select the line type for your model from the Link drop-down list. Line type means how many wires you want to use on the line side. For example, you can select 2-wire, 4-wire or 8-wire line type for the 8-wire model.
Table 7. Line Type Chart
Annex Type Select the appropriate Annex type from the drop-down list. Annex AF describes the transmission and perfor- mance requirements for North America. Annex BG describes performance and transmission requirements for Europe.
Advanced Configuration Options 41

TCPAM Type TCPAM (Trellis Coded Pulse Amplitude Modulation) is the standard used for line coding. Select the TCPAM type from the drop-down list. Auto is the default option for TCPAM. You can also manually set the TCPAM type.
Main Rate Select the line rate for your model from the Main Rate drop-down list. The main rate is the multiple of 64kbps, 128kbps, or 256kpbs- depending on your model type. Use Table 8 to determine the best main rate for your model.
Table 8. Main Rate Chart
Model Type Multiple TCPAM-16
TCPAM-128
2160 2-wire model 64 192–3840 768–5696 128–15296
2161 4-wire model 128 384–7680 1536–11392 256–30592
2162 8-wire model 256 768–15360 3072–22784 512–61184
SNR Margin Select the desired SNR Margin value from the drop-down list. SNR margin is an index of line connection quality. You can see the actual SNR margin in STATUS. You will experience better line connection quality for larger SNR margin values.
For example, if you set the SNR margin is 5, the LINE connection will drop and reconnect when the SNR margin is lower than 5. On the other hand, the device will reduce the line rate and reconnect for better line connection quality. You may select the SNR margin from the range -10 to 21.
Line Probe For adaptive mode applications, set the Line Probe to Enable. The Model 2160 will adapt the data rate accord- ing to the line status. The screen will prompt the parameters that will be written in NVRAM. Check the parameters before writing in NVRAM.
For all other applications, set the Line Probe to Disable.
Click Restart to reboot the Model 2160 with the new settings. Click Continue to configure other options.
Advanced Configuration Options 42
= 3–60 · = 12–89 · = 2–239

VLAN Click on VLAN under Advanced on the main menu to reach the VLAN advanced configuration page.

Figure 14. VLAN page
VLAN (Virtual Local Area Network) allows a physical network to be partitioned into multiple logical net- works. Devices on a logical network belong to one group. A device can belong to more than one group. With VLAN, a device cannot directly talk to or hear from devices that are not in the same group.
With MTU (Multi-Tenant Unit) applications, VLAN is vital in providing isolation and security among the subscribers. When properly configured, VLAN prevents one subscriber from accessing the network resources of another on the same LAN.
VLAN also increases network performance by limiting broadcasts to a smaller and more manageable logical broadcast domain. In traditional switched environments, all broadcast packets go to each every individual port. With VLAN, all broadcasts are confined to a specific broadcast domain.
You can select from two types of VLAN: 802.1Q Tag-Based VLAN and Port-Based VLAN. The VLAN Setup screen changes depending on whether you choose 802.1Q Tag-Based VLAN type or Port Based VLAN type. The IEEE 802.1Q defines the operation of VLAN bridges that permit the definition, operation, and adminis- tration of VLAN topologies within a bridged LAN infrastructure.
Figure 15 on page 44 shows a diagram of possible VLAN connections.
Advanced Configuration Options 43


LINK 1 2 3 4 CopperLink“2160 Long Range Ethernet Extender
Figure 15. VLAN Diagram
Advanced Configuration Options 44

802.1Q Tag-Based VLAN Click on VLAN under Advanced on the main menu to reach the VLAN advanced configuration page. Then, select the radio button for 802.1Q Tag-Based VLAN to display the configuration options.

Figure 16. 802.1Q Tag-Based VLAN page
In 802.1q, the VLAN information is written into the Ethernet packet itself. Each packet carries a VLAN ID (Virtual LAN ID) called a tag. This tag allows VLANs to be configured across multiple switches.
When using 802.1q, four bytes are added to the Ethernet frame, and 12 bits are used for the VLAN ID. Theo- retically, there can be up to 4096 VLANs per network.
An Ethernet packet that contains a VLAN ID is called a tagged packet. An Ethernet packet without a VLAN ID is called an untagged packet. Typically, all packets leave untagged, unless tagged by the adapter prior to arriving at the switch port.
Egress and Ingress Rules. Egress rules determine which frames can be transmitted out of a port, based on the Egress List of the associated VLAN. Each VLAN has an Egress List that specifies the ports out of which frames can be forwarded, and specifies whether the frames will be transmitted as tagged or untagged frames.
Ingress rules are a means of filtering out undesired traffic on a port. When Ingress Filtering is enabled, a port determines if a frame can be processed based on whether the port is on the Egress List of the VLAN associated with the frame.
When an untagged packet arrives at the switch port, the switch will write a VLAN ID into the header of the frame according to the PVID (port VLAN) definition. Typically, most switches today have all ports set to a default PVID of 1. When a tagged frame arrives at a switch port, the tag is respected.
A VID defines the member of a port group. A packet can only travel inside a member port when the member port is part of a VID port group. Different VID groups are not visible to one another.
Advanced Configuration Options 45

Tag-Based VLAN Overview. Figure 17 shows the breakdown of the VLAN tag field.

Figure 17. VLAN tag field
The Tag Control Information (TCI) section of a VLAN tag includes information on the user Priority level, the Canonical Format Indicator (CFI) and VLAN ID (VID).
The Model 2160 initially configures one VLAN by default, VID=1. A port such as LAN1–4, line or sniffing can have only one Port VID (PVID), but can have as many VID groups as the Model 2160 has memory in its VLAN table to store them.
Advanced Configuration Options 46

Ports in the same VLAN group share the same frame broadcast domin thus increase network performance through reduced boardcast traffic. You can modify VLAN groups at any time by adding, moving or changing ports without any re-cabling.

LINK 1 2 3 4 CopperLink“2160 Long Range Ethernet Extender
LINK 1 2 3 4 CopperLink“2160 Long Range Ethernet Extender
Figure 18. 802.1Q VLAN diagram
Configuring 802.1Q VLAN Tagging. Before enabling VLANs for the Model 2160, you must first assign each port to the VLAN group(s) in which it will participate. By default all ports are assigned to VLAN1 as untagged ports. Add a port as a tagged port if you want it to carry traffic for one or more VLANs, and any intermediate network devices or the host at the other end of the connection supports VLANs. Then, assign ports on the other VLAN-aware network devices along the path that will carry this traffic to the same VLAN(s), either manually or dynamically using Generic VLAN Routing Protocol (GVRP). However, if you want a port on this Model 2160 to participate in one or more VLANs, but none of the intermediate network devices nor the host at the other end of the connection supports VLANs, then you should add this port to the VLAN as an untagged port.
Advanced Configuration Options 47

Port-Based VLAN Click on VLAN under Advanced on the main menu to reach the VLAN advanced configuration page. Then, select the radio button for Port-Based VLAN to display the configuration options.

Figure 19. Port-Based VLAN page
Port-Based VLANs are VLANs where the packet forwarding decision is based on the destination MAC address and its associated port. When using port-based VLAN, the port is assigned to a specific VLAN independent of the user or system attached to the port. This means all users attached to the port should be members in the same VLAN. The network administrator typically performs the VLAN assignment. The port configuration is static and cannot be automatically changed to another VLAN without manual reconfiguration.
As with other VLAN approaches, the packets forwarded using this method do not leak into other VLAN domains on the network. After a port has been assigned to a VLAN, the port cannot send to or receive from devices in another VLAN.
Advanced Configuration Options 48

Quality of Service (QoS) Quality of Service (QoS) refers to both a network's ability to deliver data with minimum delay, and the net- working methods used to control the use of bandwidth. Without QoS, all traffic date is equally likely to be dropped when the network is congested. This can cause a reduction in network performance and mark the net- work inadequate for time-critical application such as video-on-demand.
Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page.

Figure 20. QoS page
QoS (Quality of Service) is used to decide which devices can get priorities to pass though the Model 2160 once the bandwidth is exhausted or fully saturated.
There are three types of QoS priority modes: Port Based Priority, VLAN Tag Priority and IP DSCP Priority. You can also disable the QoS function.
Advanced Configuration Options 49

Port Based Priority Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page. Then, select the radio button for Port Based Priority to display the configuration options.

Figure 21. QoS - Port Based Priority page
Select the ports that the port-based priority rule should be applied. There are six ports to choose from: LAN1, LAN2, LAN3, LAN4, DSL and Sniffing.
The common setting tables are:
WRR configuration: Each queue type can setup the queue weight from 1 to 15.
WFQ configuration: Each ports and their queue type can set the bandwidth.
Scheduling Configuration. The 2160 provides three combinations of four commonly used techniques: Type 1, Type 2 and Type 3. Select a type in the Scheduling Configuration section, then provide details in the corre- sponding table.
If you select Type 1, refer to “WRR Configuration” on page 52.
If you select Type 2 or Type 3, refer to “WFQ Configuration” on page 52.
The Queue types are Weight Round Robin (WRR), Weighted Fair Queuing (WFQ), Best Effort (BE) and Strictly Priority (SP). Refer to the following page for more information on how each Queue Type operates.
Advanced Configuration Options 50


Figure 22. WRR Example
For example, Figure 22 shows the weight value of each queue, ranging from 4, 2, 5, and 1. When the 2160 starts to process all of the packets in these queues with WRR, a new packet develops based on the weight assignments. Then, the 2160 sends out the new packet.

Figure 23. WFQ Example

Figure 24. BE Example
Advanced Configuration Options 51


Figure 25. SP Example
WRR Configuration. If you selected Type 1 in the Scheduling Configuration section, then provide infor- mation for the WRR table. Assign a weight value (from 1 to 15) to determine the priority for each queue.

Figure 26. QoS - Port Based Priority - WRR Configuration
WFQ Configuration. If you selected Type 2 or Type 3 in the Scheduling Configuration section, then pro- vide information for the WFQ table. Assign the bandwidth for each queue in each port.

Figure 27. QoS - Port Based Priority - WFQ Configuration
Port-Based Priority Table. For the last step, assign queues to their corresponding ports: LAN 1-4, DSL and Sniffing.

Figure 28. QoS - Port Based Priority Table
Advanced Configuration Options 52

VLAN Tag Priority Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page. Then, select the radio button for VLAN Tag Priority to display the configuration options.

Figure 29. QoS - VLAN Tag Priority page
VLAN Tag Priority uses the tag field information which has been inserted into an Ethernet frame. If a port has an 802.1Q-compliant device attached (such as this Ethernet Extender), these tagged frames can carry VLAN membership information.

Figure 30. IEEE 802.1Q Tagged Frame for Ethernet
Priority defines the user priority level for different classes of traffic. There are 8 possible priority levels, with 0 being the lowest priority level and 7 being the highest level. Each Priority level can be set queue from 0 to 3.
Advanced Configuration Options 53

Table 9. VLAN Tag Priority Levels
Priority Level Traffic Type
0 (default) Best Effort
5 Video, less than 100 milliseconds latency and jitter
6 Voice, less than 10 milliseconds latency and jitter
Scheduling Configuration. The 2160 provides three combinations of four commonly used techniques: Type 1, Type 2 and Type 3. Select a type in the Scheduling Configuration section, then provide details in the corre- sponding table.
If you select Type 1, refer to “WRR Configuration” on page 54.
If you select Type 2 or Type 3, refer to “WFQ Configuration” on page 54.
WRR Configuration. If you selected Type 1 in the Scheduling Configuration section, then provide infor- mation for the WRR table. Assign a weight value (from 1 to 15) to determine the priority for each queue. “Weight” determines how important the queue is; therefore, 15 is the most important queue and 0 is the least important queue.
Figure 31. QoS - Tag Based Priority - WRR Configuration
WFQ Configuration. If you selected Type 2 or Type 3 in the Scheduling Configuration section, then pro- vide information for the WFQ table. Assign the bandwidth for each queue in each port.
Figure 32. QoS - Tag Based Priority - WFQ Configuration
Advanced Configuration Options 54

VLAN Tag Priority Table. Select a packet with an assigned priority to correspond with each queue.

Figure 33. QoS - VLAN Tag Priority Table
Configuration Example. As an example, you can set the Model 2160 to use Weighted Round-Robin (WRR) queuing that specifies a relative weight of each queue. WRR uses a predefined relative weight for each queue that determines the percentage of service time to provide each queue before moving on to the next queue. This prevents the head-of-line blocking that can occur with strict priority queuing.
Table 10. WRR Scheduling Configuration Example Values
Queue 0 1 2 3
Type 1 WRR
Weight 1 2 4 8
For this example, set up the WRR (Type 1) to share bandwidth by using scheduling weights 1, 2, 4 and 8 for queues 0 through 3 respectively.
Priority 0 1 2 3 4 5 6 7
Queue 1 0 0 1 2 2 3 3
According to the two tables above, the QoS values map to the Egress Queues as follows:
Queue 0 1 2 3
Weight 2 15 7 8
Priority 0 1 2 3 4 5 6 7
Queue 0 0 2 2 3 3 1 1
This example displays that:
- Queue 1 Packets will go first because weight is equal to 15 (the biggest value).
- Queue 3 Packets will go next because the weight is the second largest value.
- Queue 2 Packets are the next after Queue 3 Packets.
- Queue 0 Packets are the last one to send.
Advanced Configuration Options 55

4,5 Queue 2 1,2 Queue 0
4,5 Queue 2 0,3 Queue 1
4,5 Queue 2 4,5 Queue 2
Figure 34. Service by WRR
IP DSCP Priority Differentiated Services Code Point (DSCP) is the 6-bit field in the header of IP packets, and it is for packet classification purposes. The DSCP algorithm is based on IP DSCP fields in the IP header. There are 64 levels of priority degrees (0 to 63). Figure 35 shows the DS field:

Figure 35. DSCP field
Advanced Configuration Options 56
6,7 Queue 3

Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page. Then, select the radio button for IP DSCP Priority to display the configuration options.

Scheduling Configuration. The 2160 provides three combinations of four commonly used techniques: Type 1, Type 2 and Type 3. Select a type in the Scheduling Configuration section, then provide details in the corre- sponding table.
WRR Configuration. If you selected Type 1 in the Scheduling Configuration section, then provide infor- mation for the WRR table. Assign a weight value (from 1 to 15) to determine the priority for each queue. “Weight” determines how important the queue is; therefore, 15 is the most important queue and 0 is the least important queue.

Figure 36. QoS - IP DSCP Priority - WRR Configuration
WFQ Configuration. If you selected Type 2 or Type 3 in the Scheduling Configuration section, then pro- vide information for the WFQ table. Assign the bandwidth for each queue in each port.

Figure 37. QoS - IP DSCP Priority - WFQ Configuration
Advanced Configuration Options 57

IP DSCP Priority Table. Select the queue for each DSCP level. Each DSCP value (from 0 to 63) is mapped to a Queue value (from 0 to 3) from the drop-down list The number 0 represents the lowest priority and num- ber 3 represents the highest priority and according various queuing strategies to tailor performance to require- ments.

Figure 38. QoS - IP DSCP Priority page
IP DSCP Configuration Example. In this example, the selected operation is Type 3. For the Type 3 combination, set up Queue 1 and Queue 2 for WFQ configuration.

For this example, assume the following actions:
Figure 39 shows the results of the configuration for the LAN 1 port.

Figure 39. DSCP Configuration Example
Advanced Configuration Options 58

Rate Limit Click on Rate Limit under Advanced on the main menu to reach the Rate Control configuration page.

Figure 40. Rate Limit page
Limiting bandwidth to specific users and ports helps control network congestion, ensure high performance, create efficient networks, and prevent a small number of users from monopolizing network bandwidth.
Rate limiting control can be used to intelligently manage bandwidth allocation in the networking. It can pre- vent one user or device from dominating the available network bandwidth, and it allows IT managers to allo- cate greater bandwidth to the departments and applications that need it.
You can set up the data rate limit on each port from 0 to 22. The data rates available are 00 (No limit), and the Ingress Rate x 1024kbps. The default setting is No limit on each port.
Flow Control Click on Flow Control under Advanced on the main menu to reach the Flow Control configuration page. When the Flow Control option is enabled, the 2160 controls the packet size.

Figure 41. Flow Control page
Advanced Configuration Options 59

This section contains information for monitoring status options for the Model 2160 via the WMI. The Status menu contains Line, Management, LAN, Performance and Syslog parameters.
LINE Status The LINE Status includes information for the run-time device status, mode, Bitrate and Performance infor- mation such as SNR margin, atteunation and CRC error count.

Figure 42. LINE Status page (8-wire model shown)
If two Model 2160s have been linked together, you can view their run-time line rate status and performance information from this screen. If you want to clear the performance data, click Clear CRC Error.
Management Status The Management Status page displays information about the Management port interface. You can view the general status of the Management interface and DHCP client table.

Figure 43. Management Status page
Status Options 60

LAN Status The LAN Status page displays information about a LAN port. The system will allow you to select which LAN port to view.

Figure 44. LAN Status page
Performance Status The Performance Status page displays information about the uptime and errors of the system.

Figure 45. Performance Status page
Status Options 61

This section allows you to configure administration options for Security, Simple Network Management Proto- col (SNMP) and Remote System Log.
Security Administration For system security, you should change the default user name and password during initial setup. Otherwise, unauthorized persons can access the Model 2160 and change the parameters. Click Security in the Administra- tion menu to set up the parameters.

Figure 46. Security Administration page
User Profiles For better security, change the Supervisor ID and Supervisor Password for the Model 2160. If you don't set them, all users will be able to access the Model 2160 using the default Supervisor ID and Supervisor Password ,which is root.
You can authorize five legal users to access the Model 2160 via telnet or console only. There are two UI modes, menu driven mode and command mode to configure the Model 2160. The default user name and Password are admin. There are two UI modes, the WMI and the Telnet/Console mode to set up the Model 2160.
Telnet Console Mode Web Browser Mode
All functions are available
All functions are available
Figure 47. Model 2160 configuration modes

Remote Management Hosts The Remote Management Host section of the Security Administration page enables you to set up the legal IP addresses from which authorized persons can configure the Model 2160. This is the most secure way for the network administrator to set up the legal address of configuration.

Figure 48. Remote Management Host section
A configuration of 0.0.0.0 will allow all hosts on Internet or LAN to access the Model 2160. If you leave the trusted host list completely blank, you will block all PCs on the WAN from accessing the Model 2160. On the other hand, only PCs in the LAN can access the Model 2160. If you type the exact IP address in the filed, only that host can access the Model 2160.
Click Finish to commit your changes. The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to reboot the Model 2160 with the new settings. Click Continue to con- figure other options.
SNMP Administration Simple Network Management Protocol (SNMP) provides for the exchange of messages between a network management client and a network management agent for remote management of network nodes. These mes- sages contain requests to get and set variables that exist in network nodes in order to obtain statistics, set con- figuration parameters, and monitor network events. SNMP communications can occur over the LAN or WAN connection.
The Model 2160 can generate SNMP traps to indicate alarm conditions, and it relies on SNMP community strings to implement SNMP security. This Model 2160 support both MIB I and MIB II.
Administration Options 63

Click SNMP in the Administration menu to set up the parameters.

Figure 49. SNMP Administration page
Community Pool An SNMP community is a group of devices and management stations running SNMP. It helps define where information is sent. The community name is used to identify the group. A SNMP device or agent may belong to more than one community. It will not request information from management stations that do not belong to one of its communities.
Table 11. Default SNMP Communities
Click Modify to set up community pools.

Figure 50. SNMP community pool configuration
In the table of the current community pool, you can set up access:

After configuring the community pool, click Finish. The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to reboot the Model 2160 with the new settings. Click Continue to configure other options.
Trap Host Pool In the table of current trap host pool, you can set up the trap host. SNMP trap is an informational message sent from an SNMP agent to a manager. It is a management station (SNMP application) that receives traps. If you don’t define a trap host pool, then no traps are issued.
Click Modify to set up the trap host pool.

Figure 51. Trap host pool configuration
Click OK to finish the setup. The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to reboot the Model 2160 with the new settings. Click Continue to configure other options.
Remote Syslog Click Remote Syslog in the Administration menu to send the log information of the 2160 to a remote site.

Figure 52. Remote Syslog configuration page
Administration Options 65

This section allows you to manage utility options for the Model 2160, including system information, the con- figuration tool, upgrade information, log out of the system, and restart the system.
System Information To review system information, click System Info in the Utility menu.

Figure 53. System Information page
You can check the MCSV, Software Version, Chipset, Firmware Version, Host Name and System Up Time. The System Up Time item let you know how long the Model 2160 has been running since powering up.
Configuration Tool The configuration tool has three options: Load Factory Default, Restore Configuration, and Backup Config- uration. Click Config Tool in the Utility menu.

Figure 54. Configuration Tool page
Select the desired configuration function, then click Finish.
Utility Options 66

Upgrade You can update the firmware of Model 2160 using the Upgrade function. Click Upgrade in the Utility menu.

Figure 55. Upgrade page
Type the path and file name of the Firmware file you wish to upload to the Model 2160 in text box. Or, you can also click Browse to locate the file. Click OK to begin the upgrade process. The system will reboot auto- matically after finishing. (Firmware upgrades will only take effect after the system reboots).
After the firmware upgrade process is complete, click System Info in the Utility menu to verify your current firmware version number.
Utility Options 67

Logout To exit the Model 2160 Web Management Interface securely, click Logout in the Utility menu. You have to log in with your password again after you log out. This is recommended after you finish a management session for security reasons.

Figure 56. Logout page
Restart To reboot the Model 2160, click Restart in the Utility menu, then click the Restart button.

Figure 57. Restart page
The following screen displays:

Figure 58. Restart page
Utility Options 68



This chapter provides information for configuring the Model 2160 by using the serial console with Telnet.
Log in to the console interface The console port is a RJ-48C connector that provides a connection to a PC for monitoring and configuring the Model 2160. Use the supplied serial cable with a female DB-9 connector to connect to the serial port of PC, and connect the RJ-48C module jack connector to the Model 2160's console port. Start your terminal emula- tion program (such as Hyper Terminal) and configure the communication parameters. Use the settings shown in Table 12 to log into the console:
Table 12. Console settings
After you enter the settings for the console, press the spacebar until the login screen appears. When you see the login screen, you can log on to the Model 2160. Enter admin for both the User Name and Password.
Log in using Telnet The Model 2160 also supports Telnet for remote management. Connect the Ethernet cable to the Manage- ment port of Model 2160 to your computer. The Management LED on the front panel of the Model 2160 will light up. Start your Telnet client with VT100 terminal emulation and connect to the management IP of the Model 2160. Wait for the login prompt to display. Enter your user name and password. When you see the login screen, you can log on to the Model 2160. Enter admin for both the User Name and Password.
Interface commands Before changing the configuration, familiarize yourself with the operations list in the following table:
Table 13. Interface commands
or I Move to the field above in the same level menu.
or K Move to field below in the same level menu.
or J Move back to the previous menu.
or L or [ENTER] Move forward to the submenu.
[HOME] or U Move to the first field. [END] or O Move to the last field. [TAB] Choose another parameter. Ctrl + C Quit configuring the item. Ctrl +Q Access help.

The Model 2160 uses a menu-driven interface for serial console and Telnet management. This interface dis- plays all available commands for configuring the Ethernet Extender.
The following figure shows an example of the menu-driven interface. In the menu, scroll up/down by pressing the I / K keys. Select one command by pressing the L key. Go back to a higher level of the menu by pressing the J key. You can also scroll to the top/bottom with the U/O keys.
For example, to show the system information, log on to the Model 2160. Press the K key twice and select the show command with the L key. Select the system command in the submenu. The system will display general information. You may also use the Enter key to select a command.

Figure 59. Console/Telnet Menu
Window structure From top to bottom, the window is divided into four parts:
Introduction 72

The commands available in the main menu tree depend on if you have logged in using a supervisor password (authorized user) or not (unauthorized user). An authorized user can access all of the configuration commands in the subdirectories using the enable command. Unauthorized users cannot change any configurations but can view the status and information for the Model 2160. They may also use the ping command to check the Model 2160’s connection.
Menu tree for authorized users Authorized users may log into the Model 2160 with a supervisor password to obtain access to all of the config- uration commands.

Figure 60. Menu tree for authorized users
Main Menu Tree 73


Figure 61. Main screen for authorized users
Menu tree for unauthorized users Unauthorized users may access the following configuration commands for the Model 2160.

Figure 62. Main menu for unauthorized users

Figure 63. Main screen for unauthorized users
Main Menu Tree 74

The enable command menu lists commands for setting up the Model 2160. Move the cursor “ >>” to enable and press Enter. Type the supervisor password, which is root.
Message: Please input the following information.
In the enable sub menu, you can set up management features and upgrade software, back up the system config- uration and restore the system configuration via utility tools.
To save your changes, you must write the new configuration to NVRAM and reboot the Model 2160 to work with the new settings.
When you first log in to the Model 2160 with the supervisor password, the main menu displays:
>> enable Modify command privilege
status Show running system status
show View system configuration
write Update flash configuration
reboot Reset and boot system
ping Packet internet groper command
admin Setup management features
utility TFTP upgrade utility
Table 14 explains the commands available in the main menu:
Table 14. Enable Command Menu
enable Change the configuration and write changes to nonvolatile RAM (NVRAM).
setup Initially configure the Model 2160.
status View the status of the Model 2160
show Show the system and configuration
write Update flash configuration. After you have completed all desired changes, make sure to write the new configuration to NVRAM. Use the write command to save your changes and reboot the system or all of your changes will not take effect.
reboot Reset and reboot system. After you have completed all desired changes, make sure to write the new configuration to NVRAM. Use the reboot command to restart the system or all of your changes will not take effect.
ping Check the connection to the Model 2160
admin Set up advanced management features
utility Upgrade software and backup/restore the current configuration
exit Log out of the system
Enable Command Menu 75

The setup command menu lists commands for initially configuring the Model 2160. Move the cursor “ >>” to setup in the main menu and press Enter.
When you enter the setup command, the following menu displays:
>> line Configure line parameters
lan Configure LAN interface profile
vlan Configure virtual LAN parameters
qos Configure Quality of Service parameters
rate Configure Rate Control parameters
Configure management interface profile
dhcp Configure DHCP parameters
dns_proxy Configure DNS proxy parameters
hostname Configure local host name
default Restore factory default settings
Line The line command menu lists commands for setting up the line port. Move the cursor “ >>” to line in the setup menu and press Enter. The following menu displays:
>> mode Configure line mode
link Configure line link
annex Configure line annex type
tcpam Configure line TCPAM type
maxMainRate Configure line max main data rate
snrMargin Configure line SNR margin
lineProbe Configure line line probe
clear Clear current CRC error count
Table 15 shows the options available within the line command menu:
Table 15. Line Options
Mode F STU-C F STU-R
Link Type F 2-wire F 4-wire F 8-wire
Annex F AF F BG
TCPAM F Auto F TCPAM-16 F TCPAM-32 F TCPAM-64
Max Main Rate (3–89)
Line Probe F Disable F Enable
Setup Command Menu 76
Manage- ment · Menu Options · SNR Margin (-10–21)

Mode There are two types of Line mode:
Link Select the line type for your model. Line type means how many wires you want to use on the CopperLink con- nection. For example, you can select 2-wire, 4-wire or 8-wire line type for the 8-wire model.
Table 16. Line Type Chart
Annex Type Enter the appropriate Annex type. Annex AF describes the transmission and performance requirements for North America. Annex BG describes performance and transmission requirements for Europe.
TCPAM Type TCPAM (Trellis Coded Pulse Amplitude Modulation) is the standard used for line coding. Select the TCPAM type. Auto is the default option for TCPAM.
Maximum Main Rate Select the line rate for your model. The main rate is the multiple of 64kbps, 128kbps, or 256kbps- depending on your model type. Use Table 17 to determine the best main rate for your model.
Table 17. Main Rate Table
Model Type Multiple TCPAM-16
TCPAM-128
2160 2-wire model 64 192–3840 768–5696 128–15296
2161 4-wire model 128 384–7680 1536–11392 256–30592
2162 8-wire model 256 768–15360 3072–22784 512–61184
SNR Margin SNR margin is an index of line connection quality. Generally, you won’t need to change the SNR Margin. You can view the actual SNR margin in status command menu.You will experience better line connection quality for larger SNR margin values.
For example, if you set the SNR margin ias 5, the line connection will drop and reconnect when the SNR mar- gin is lower than 5. On the other hand, the device will reduce the line rate and reconnect for better line con- nection quality. You may select the SNR margin from the range -10 to 21.
Setup Command Menu 77

Line Probe For adaptive mode applications, set the Line Probe to Enable. The Model 2160 will adapt the data rate accord- ing to the line status. For all other applications, set the Line Probe to Disable.
Clear Use the clear command to reset the CRC error count.
LAN The lan command menu lists commands for setting up the LAN ports. Move the cursor “ >>” to lan in the setup menu and press Enter.
Message: Please input the following information.
The default interface number is 1.
You can configure the Link type, LAN IP address and subnet mask for the LAN interface.
>> link_type Configure Link type
address LAN address and subnet mask
Table 18 shows the options available within the lan command menu:
Table 18. LAN Options
Link Type F Disable F Dynamic F Static
Message: Please input the following information.
Link type (TAB Select) :
Select the lan 1 link_type as Disable, Dynamic or Static. Then, select address from the lan menu:
Message: Please input the following information.
IP address (ENTER for default) :
Subnet mask (ENTER for default) :
Set the LAN IP address and subnet mask. The default IP Address is 192.168.2.1 and the default subnet mask is 255.255.255.0.
Setup Command Menu 78

VLAN Virtual LAN (VLAN) is defined as a group of devices on one or more LANs that are configured so that they can communicate as if they were attached to the same wire, when in fact they are located on a number of differ- ent LAN segments. Because VLAN is based on logical instead of physical connections, it is extremely flexible.
You can setup the Virtual LAN (VLAN) parameters in VLAN command. The Model 2160 supports VLAN- to-PVC only for bridge mode operation, i.e., the VLAN spreads over both the CO and CPE sides, where there is no layer 3 routing involved. The unit supports up to 8 active VLANs with shared VLAN learning (SVL) bridge out of 4096 possible VLANs specified in IEEE 802.1Q.
The vlan command menu lists commands for setting up the line port. Move the cursor “ >>” to vlan in the setup menu and press Enter. The following menu displays:
>> mode Trigger virtual LAN function
modify Modify virtual LAN table
pvid Modify port default VID
link_mode Modify port link type
list Show VLAN configuration
To activate the VLAN function, move the cursor “ >> “ to mode and press Enter. The products support two types of VLAN: 802.1Q and Port-Based.
802.1Q defines the operation of VLAN bridges that permit the definition, operation, and administration of VLAN topologies within a bridged LAN infrastructure. Port-Based VLANs are VLANs where the packet for- warding decision is based on the destination MAC address and its associated port.
Mode You can choose from two types of VLANs: 802.1Q Tag-Based VLAN or Port Based VLAN. If you are not going to use the VLAN function, set this option to Disable.
Message: Please input the following information.
Trigger VLAN function (TAB Select) :
Table 19 shows the options available within the VLAN mode command menu:
Table 19. VLAN Mode Options
VLAN Mode F Disable F 802.1Q Tag VLAN F Port-Based VLAN
Setup Command Menu 79
· Menu Options

802.1Q VLAN. To modify the VLAN rule, move the cursor to modify and press Enter.
Message: Please input the following information.
VID value (ENTER for default) : 10
VLAN port membership (ENTER for default) :
The VLAN Port membership ris represented with 1 or 0. VLAN port membership is a 6-digit binary number in which bit 0 to bits 5 represent LAN1 to LAN4, line and Sniffing ports respectively.
For example: [ setup vlan modify 1 10 111111 ] means use index as 1 , VID = 10 and all six ports are the same membership (VLAN ID=10).
Use the pvid command to change the member port to untagged members:
Message: Please input the following information.
Port index :
VID value (ENTER for default) :
PVID (Port VID) is an untagged member from 1 to 4094 for the default VLAN.
For example:
[ set vlan pvid 1 100]
[ set vlan pvid 2 100]
[ set vlan pvid 3 100]
[ set vlan pvid 4 100]
[ set vlan pvid 5 100]
[ set vlan pvid 6 100]
This example shows that all untagged members of all ports all have the same membership (VLAN ID=100).
To modify the link type of the port, move the cursor to link_mode and press Enter. There are two types of link: access and trunk. A Trunk link will send the tagged packet form the port. An Access link will send an untagged packet from the port. The port index 1 to 4 represents LAN ports. Index 5 represents line, and index 6 represents Sniffing.
Setup Command Menu 80
·

Message: Please input the following information.
Port link type (TAB Select) :
Table 20 shows the options available within the 802.1Q Tag VLAN command menu:
Access The port can receive or send untagged packets.
Trunk The port can receive or send tagged packets.
Table 20. 802.1Q VLAN Options
1 2 3 4 5 6
No. VID LAN1 LAN2 LAN3 LAN4 Line Sniffing 1 2 3 4 5 6 7 8 PVID Link Type F Access
Port-Based VLAN. With port-based VLAN, the port is assigned to a specific VLAN independent of the user or system attached to the port. This means all users attached to the port should be members in the same VLAN. The network administrator typically performs the VLAN assignment. The port configuration is static and cannot be automatically changed to another VLAN without manual reconfiguration.
You can set up Port-Based VLAN using the method for 802.11Q. However, VID , PVID or link type do not matter for Port-Based VLAN. Use the list command to check the status of the VLAN.
No LAN1 LAN2 LAN3 LAN4 Line Sniffing
--
1
Setup Command Menu 81

QoS Quality of Service (QoS) refers to both a network's ability to deliver data with minimum delay, and the net- working methods used to control the use of bandwidth. Without QoS, all traffic date is equally likely to be dropped when the network is congested. This can cause a reduction in network performance and mark the net- work inadequate for a time-critical application such as video-on-demand.
The qos command menu lists commands for managing traffic. Move the cursor “ >>” to qos in the setup menu and press Enter. The following menu displays:
>> mode Trigger Quality of Service function
qSchdl Modify queue schedule type
qweight Modify queue weight
q0GrssRt Modify queue 0 egress rate
q1GrssRt Modify queue 1 egress rate
q2GrssRt Modify queue 2 egress rate
q3GrssRt Modify queue 3 egress rate
portPri Modify port priority
vlanTagPri Modify VLAN TAG priority
ipDscpPri Modify IP DSCP priority
list Show QoS configuration
Mode You can choose from three types of QoS: Port-Based, VLAN Tag, and IP DSCP. If you are not going to use the QoS function, set this option to Disable.
Message: Please input the following information.
Trigger qoS function (TAB Select) :
Table 21 shows the options available within the QoS mode command menu:
Table 21. VLAN Mode Options
QoS Mode F Disable F Port-Based F VLAN Tag F IP DSCP
Queue Schedule There are two types of queue schedule. Select from Type 1, Type 2 or Type 3. Table 22 explains the schedule types:
Table 22. Queue Schedule Types
Queue 0 1 2 3
Type 1 WRR
Type 2 BE WFQ WFQ WFQ
Type 3 BE WFQ WFQ SP
Setup Command Menu 82
· Menu Options

Message: Please input the following information.
The Queue types are Weight Round Robin (WRR), Weighted Fair Queuing (WFQ), Best Effort (BE), and Strictly Priority (SP).
Table 23. Queue Schedule Options
Queue Schedule F Type 1 F Type 2 F Type 3
Queue Weight This setting configures the weight value for each queue.
Message: Please input the following information.
Weight value (ENTER for default) : 1
For example, the default values are shown below:
[ setup qos qweight 0 1]
[ setup qos qweight 1 2]
[ setup qos qweight 2 4]
[ setup qos qweight 3 8]
QoS Mode 0 1 2 3 Weight Value
Setup Command Menu 83
· Menu Options ·

Queue Egress Rate Queues 0-3 can set up the egress rate for WFQ configuration.
q0GrssRt Modify queue 0 egress rate
q1GrssRt Modify queue 1 egress rate
q2GrssRt Modify queue 2 egress rate
q3GrssRt Modify queue 3 egress rate
The egress rate N value can be set from 0 to 22. The N value 0 means no limits.
The egress data rate is a multiple of 1024kbps.
For example, the egress data rate = N value (1 to 22) x 1024 Kbps.
Table 24. Egress Rate (N Value)
0 1 2 3
LAN 2
LAN 3
LAN 4
DSL
Message: Please input the following information.
Queue index (ENTER for default) : 3
Set up the queue value (0, 1, 2 or 3) on each port.
Table 25. Port-Based Priority QoS Options
Port 1 (LAN1) 2 (LAN2) 3 (LAN3) 4 (LAN4) 5 (Line) 6 (Sniffing)
VLAN Tag Priority QoS
Message: Please input the following information.
Queue index (ENTER for default) : 1
Set up the queue index (0, 1, 2 or 3) on Priority VLAN Tag.
Setup Command Menu 84

VLAN Tag Priority uses the tag field information which has been inserted into an Ethernet frame. If a port has an 802.1Q-compliant device attached (such as this Ethernet Extender), these tagged frames can carry VLAN membership information.
Priority defines the user priority level for different classes of traffic. There are 8 possible priority levels, with 0 being the lowest priority level and 7 being the highest level. Each Priority level can be set queue from 0 to 3.
Table 26. VLAN Tag Priority Levels
Priority Level Traffic Type
0 (default) Best Effort
5 Video, less than 100 milliseconds latency and jitter
6 Voice, less than 10 milliseconds latency and jitter
For example, you can set the Model 2160 to use Weighted Round-Robin (WRR) queuing (Type 1) that speci- fies a relative weight of each queue. WRR uses a predefined relative weight for each queue that determines the percentage of s time to services for each queue before moving on to the next queue.
Table 27. VLAN Tag Priority QoS Options
VLAN Tag Index 0 1 2 3 4 5 6 7
IP DSCP Priority QoS Differentiated Services (DiffServ) is a class of service (CoS) model that enhances best-effort Internet services by differentiating traffic by users, service requirements and other criteria. Packets are specifically marked, allowing network nodes to provide different levels of service, as appropriate for video playback, voice calls or other delay-sensitive applications, via priority queuing or bandwidth allocation.
The DSCP value used to identify 64 levels (26=64) of service determines the forwarding behavior that each packet gets across the DiffServ network. Based on the marking rule different kinds of traffic can be marked for different priorities of forwarding. Resources can then be allocated according to the DSCP values and the con- figured policies.
Set up queue index (0, 1, 2 or 3) on each DSCP:
Message: Please input the following information.
Queue index (ENTER for default) :
Setup Command Menu 85

Table 28. IP DSCP Priority QoS Options

DSCP Queue Index DSCP Queue Index DSCP Queue Index DSCP Queue Index 0 16 32 48 1 17 33 49 2 18 34 50 3 19 35 51 4 20 36 52 5 21 37 53 6 22 38 54 7 23 39 55 8 24 40 56 9 25 41 57 10 26 42 58 11 27 43 59 12 28 44 60 13 29 45 61 14 30 46 62 15 31 47 63
List Use the list command to view the QoS settings.
Rate The rate command menu lists commands for setting the port rate. Move the cursor “ >>” to rate in the setup menu and press Enter. The following menu displays:
>> port Modify port rate
list Show Rate Control configuration
Select the port you want to modify, then set up the data rate.
Message: Please input the following information.
rate (ENTER for default) :
The data rate is a multiple of 1024kbps with the setup rate. Table 29 shows the options available to set up the data rate:
Table 29. Rate Options

Port 1 LAN1 F No Limit F 128K F 256K F 512K F 1M F
Port 2 LAN2 F No Limit F 128K F 256K F 512K F 1M F
Port 3 LAN3 F No Limit F 128K F 256K F 512K F 1M F
Port 4 LAN4 F No Limit F 128K F 256K F 512K F 1M F
Port 5 Line F No Limit F 128K F 256K F 512K F 1M F
Port 6 Sniffing F No Limit F 128K F 256K F 512K F 1M F
Setup Command Menu 86

Management The Management command menu lists commands for configuring the IP address and subnet mask for the Management port. Move the cursor “ >>” to Management in the setup menu and press Enter. The following menu displays:
>> address Management IP address and subnet mask
Message: Please input the following information.
Interface number :
The Model 2160 only has one Management interface. The default interface number is 1. The default IP address and subnet mask are 196.168.1.1 and 255.255.255.0 .
Message: Please input the following information.
IP address (ENTER for default) :
Subnet mask (ENTER for default) :
DHCP Dynamic Host Configuration Protocol (DHCP) is a communication protocol that allows network adminis- trators to manage and automate the assignment of Internet Protocol (IP) addresses in an organization's net- work. Each machine that can connect to the Internet needs a unique IP address. When an organization sets up the users with a connection to the Internet, an IP address must be assigned to each machine.
Without DHCP, the IP address must be entered manually at each computer. If computers move to another location in another part of the network, a new IP address must be entered. DHCP lets a network administrator supervise and distribute IP addresses from a central point and automatically sends a new IP address when a computer is plugged into a different place in the network.
Setup Command Menu 87
· ·

DHCP Server The dhcp command menu lists commands for configuring DHCP settings. Move the cursor “ >>” to dhcp in the setup menu and press Enter. The following menu displays:
>> generic DHCP server generic parameters
fixed DHCP server fixed host IP list
list Show DHCP configuration
The generic command menu lists commands for configuring general DHCP settings. Move the cursor “ >>” to generic in the dhcp menu and press Enter. The following menu displays:
>> active Trigger DHCP server function
gateway Default gateway for DHCP client
netmask Subnet mask for DHCP client
ip_range Dynamic assigned IP address range
lease_time Configure max lease time
name_server1 Domain name server1
name_server2 Domain name server2
name_server3 Domain name server3
Table 30. DHCP Command Descriptions
Active Trigger DHCP server function
Gateway Configure default gateway for DHCP client
Netmask Configure subnet mask for DHCP client
IP Range Configure dynamic assigned IP address range
Lease Time Set up dynamic IP maximum lease time
Name Server 1 Set up the IP address of name server #1
Name Server 2 Set up the IP address of name server #2
Name Server 3 Set up the IP address of name server #3
DHCP Fixed Host The dhcp command menu lists commands for configuring DHCP settings. Move the cursor “ >>” to dhcp in the setup menu and press Enter. The following menu displays:
generic DHCP server generic parameters
>> fixed DHCP server fixed host IP list
relay DHCP relay parameter
list Show DHCP configuration
The fixed command menu lists commands for configuring a Fixed Host IP Address list. Move the cursor “ >>” to fixed in the dhcp menu and press Enter. The following menu displays:
>> add Add a fixed host entry
delete Delete a fixed host entry
Setup Command Menu 88
Command Description

When using the fixed host entry function, you must enter the MAC address and IP address at the same time. You can configure up to 10 maximum fixed host IP addresses.
Use the list command to view the DHCP configuration.
DNS Proxy The dns_proxy command allows you to set up three DNS servers for the Model 2160. Move the cursor “ >>” to dns_proxy in the setup menu and press Enter.
Message: Please input the following information.
DNS server 1 (ENTER for default) : 10.0.10.1
DNS server 3:
Host Name A Host Name is a unique name that attaches a host to a network. The hostname is used to identify a particular host in various forms of electronic communication. Some ISP providers require the Host Name as identifica- tion. You may check with your ISP to see if your Internet service has been configured with a host name. In most cases, you can ignore this field.
Move the cursor “ >>” to hostname in the setup menu and press Enter. The host name cannot use spaces and cannot have more than 15 characters.
Message: Please input the following information.
Local hostname (ENTER for default) : test
Factory Default If you want to restore factory default settings for the Model 2160, move the cursor “ >>” to default in the setup menu and press Enter.
Message: Please input the following information.
Setup Command Menu 89

The status command menu lists commands for viewing the system status of interfaces on the Model 2160. Move the cursor “ >>” to status in the main menu and press Enter.
When you enter the status command, the following menu displays:
>> LINE Show LINE status
interface Show interface statistics status
Table 31. Status Command Menu
LINE The LINE status includes mode, line rate, SNR margin, attenuation, and CRC error count of the local side modem, and SNR margin, attenuation and CRC error count of remote side modem. The modem can access remote side information via EOC (embedded operation channel).
interface Use the interface command to view the statistic status of the Management interface.
LINE Status The LINE command shows the status of the Line port. Move the cursor “ >>” to LINE in the status menu and press Enter. The LINE status includes mode, line rate, SNR margin, attenuation, and CRC error count of the local side Ethernet Extender, and SNR margin, attenuation and CRC error count of the remote side Ethernet Extender.

Figure 64. LINE Status
Status Command Menu 90
Command Description

Interface Status To view the status of the Management interface, move the cursor “ >>” to interface in the status menu and press Enter.

Figure 65. Interface Status
Table 32. Interface Statistics
InOctets The number of received bytes on this port
InPackets The number of received packets on this port
OutOctets The number of transmitted bytes on this port
OutPackets The number of transmitted packets on this port
InDiscards The discarded number of received packets on this port
OutDiscards The discarded number of transmitted packets on this port
Status Command Menu 91
Parameter Description

The show command menu lists commands for viewing system and configuration information for the Model 2160. Move the cursor “ >>” to show in the main menu and press Enter.
When you enter the show command, the following menu displays:
>> system Show general information
script Show all configuration in command script
Table 33. Show Command Menu
system Displays general system information
script Displays configuration information in command script
Move the cursor “ >>” to system in the show menu and press Enter.

Figure 66. System Information

Figure 67. Show Script
Show Command Menu 92
Command Description

The write command saves all new configuration changes to Flash on the Model 2160. You must use the write command and reboot the Ethernet Extender for new configuration changes to tak effect. Move the cursor “ >>” to write in the main menu and press Enter.
Message: Please input the following information.
The reboot command restarts the Model 2160. Move the cursor “ >>” to reboot in the main menu and press Enter.
Message: Please input the following information.
Do you want to reboot? (y/n): y
Type “y” to begin the reboot process.
The ping command checks the connection of the Model 2160 to the network. Move the cursor “ >>” to ping in the main menu and press Enter.
The ping command sends an echo request packet to an address, and then waits for reply. The ping output can help you evaluate path-to-host reliability, delays over the path, and whether the host can be reached or is func- tioning correctly.
Message: Please input the following information.
Number of ping request packets to send (TAB select): -t
There are 3 parameters for the ping command:

Ping Command 94

The admin command menu lists commands for modifying user profiles, Telnet access, Simple Network Man- agement Protocol (SNMP), and supervisor information (username and password). Move the cursor “ >>” to admin in the main menu and press Enter.
When you enter the admin command, the following menu displays:
>> user Manage user profile
security Setup system security
snmp Configure SNMP parameter
passwd Change supervisor password
id Change supervisor ID
User Profile The user command menu lists commands to clear, modify, and list user profiles. You can create up to 5 user profiles to access the Model 2160 vis the console port. However, users with supervisor privleges have access to changing the configuration of the Model 2160.
Move the cursor “ >>” to user in the admin menu and press Enter. The following menu displays:
>> clear Clear the user profile
modify Modify the user profile
list List the user profile
Use the clear command to delete a user. Use the list command to show information for a user profile. Use the modify command to edit user information or add a new user to a user profile.
Modify/Add User To modify a user profile or add a new user, move the cursor “ >>” to modify in the user menu and press Enter. Select the profile number for the user profile you want to modify.
Message: Please input the following information.
Legal access user profile number : 2
The modify menu displays:
>> attrib UI mode
profile User name and password
Move the cursor “ >>” to attrib in the modify menu and press Enter.
Message: Please input the following information.
User interface (TAB Select) :
Administration Command Menu 95
· ·

There are two UI modes for setting up the Model 2160, command and menu mode. The menu mode uses a menu-driven interface. The command mode uses line commands. (Command mode is not covered in this manual).
Move the cursor “ >>” to profile in the modify menu and press Enter.
Message: Please input the following information.
Legal user name (ENTER for default) :
Enter the user name and set up the new access password. You must enter the new assess password twice for confirmation.
Use the list command to view information for each user profile, including user name and UI mode.
Security The security command menu lists commands to configure sixteen legal IP addresses for Telnet access and the Telnet port number. Move the cursor “ >>” to security in the admin menu and press Enter. The following menu displays:
>> port Configure telnet TCP port
ip_pool Legal IP address pool
list Show security profile
Telnet TCP Port To set up the Telnet TCP port, move the cursor “ >>” to port in the security menu and press Enter. You can select a port number from 1 to 65534. The default number is 23.
Message: Please input the following information.
Telnet Listening TCP Port (ENTER for default) :
Legal IP Address Pool The default legal address is 0.0.0.0. (on entry number 1). This means that there are no IP address restrictions for accessing the MOdel 2160 via Telnet. To change the legal IP address pool, move the cursor “ >>” to ip_pool in the security menu and press Enter. Select modify to set up the IP address pool.
Administration Command Menu 96
· ·

Message: Please input the following information.
Client address pool entry number : 1
Client IP address (ENTER for default) :
You can configure up to sixteen entries for legal address pools. Use the clear command to remove a legal client IP address from any pool entry number. Use the list command to view information for all of the security pro- files, including the Telnet TCP port and the legal IP addresses.
SNMP Simple Network Management Protocol (SNMP) provides the exchange of messages between a network man- agement client and a network management agent for remote management of network nodes. These messages contain requests to get and set variables that exist in network nodes in order to obtain statistics, set configura- tion parameters, and monitor network events. SNMP communications can occur over the LAN or WAN con- nection.
The Model 2160 can generate SNMP traps to indicate alarm conditions, and it relies on SNMP community strings to implement SNMP security. This Model 2160 support both MIB I and MIB II.
The snmp command menu lists commands for configuring SNMP communities and traps. Move the cursor “ >>” to snmp in the admin menu and press Enter. The following menu displays:
>> community Configure community parameter
trap Configure trap host parameter
Community To set up SNMP communities, move the cursor “ >>” to community in the snmp menu and press Enter. You can configure five community entries.
Message: Please input the following information.
The following menu displays:
>> edit Edit community entry
list Show community configuration
Select edit and press Enter.
Administration Command Menu 97
·

Message: Please input the following information.
Community (ENTER for default) :
Access right (TAB Select) :
You can set up the following options:
Read_Only Users have read-only access to the community
Read_Write Users have read and write access to the community
Denied There is no access to the community
Use the list command to view all SNMP community pool entries. You can also confgiure five SNMP trap entries.
Trap host To set up SNMP traps, move the cursor “ >>” to trap in the snmp menu and press Enter. You can configure five trap entries.
Message: Please input the following information.
The following menu displays:
>> edit Edit trap host parameter
list Show trap configuration
Select edit and press Enter.
Message: Please input the following information.
Version (TAB Select) :
Trap host IP address (ENTER for default) :
Community (ENTER for default) :
Administration Command Menu 98

You can set up the following options:
Use the list command to view all SNMP trap host entries.
Supervisor Password and ID The supervisor ID and password is the last option in the security command menu, but it is the most important menu item. Users who access the Model 2160 via a web browser or console/Telnet must use the supervisor ID and password to configure the Model 2160. You should change the supervisor ID and password after initial configuration.
Supervisor Password To change the supervisor password, move the cursor “ >>” to passwd in the security menu and press Enter. The default password is root.
Message: Please input the following information.
Supervisor ID To change the supervisor ID, move the cursor “ >>” to id in the security menu and press Enter. The default ID is root.
Message: Please input the following information.
Legal user name (ENTER for default) :
Figure 47 on page 62 shows a flowchart of user access functions using the web browser or console/Telnet.
Administration Command Menu 99

Model 2160 has three utility tools embedded in the firmware: upgrade, backup and restore. You can update the new firmware via TFTP upgrade tools, backup the configuration via the TFTP backup tool and restore the configuration via the TFTP restore tool. To upgrade the firmware, you must have the new firmware file named *.bin that will be supported by supplier. Also, you must have your own TFTP server. For backup and restore operations, you must also have your own TFTP server to backup and restore the configuration files.
Move the cursor “ >>” to utility in the main menu and press Enter. The following menu displays:
>> upgrade Upgrade main software
backup Backup system configuration
restore Restore system configuration
Upgrade main software To upgrade the Model 2160 firmware, move the cursor “ >>” to upgrade in the utility menu and press Enter. Type the TFTP server IP address and name of the upgraded firmware file.
Message: Please input the following information.
TFTP server IP address (ENTER for default) :
Upgrade filename (ENTER for default) :
Backup system configuration To backup the current system configuration, move the cursor “ >>” to backup in the utility menu and press Enter. Type the TFTP server IP address and name for the backup file.
Message: Please input the following information.
TFTP server IP address (ENTER for default) :
Upgrade filename (ENTER for default) :
Restore system configuration To restore a saved configuration file, move the cursor “ >>” to restore in the utility menu and press Enter. Type the TFTP server IP address and name of the system configuration file you want to restore to the Model 2160.
Message: Please input the following information.
TFTP server IP address (ENTER for default) :
Upgrade filename (ENTER for default) :
Utility Command Menu 100

Utility Command Menu 101

To log out of the system without saving your changes, move the cursor “ >>” to exit in the main menu and press Enter.
enable Modify command privilege
status Show running system status
show View system configuration
write Update flash configuration
reboot Reset and boot system
ping Packet internet groper command
admin Setup management features
utility TFTP upgrade utility
>> exit Quit system
Message: Please input the following information.
Do you want to disconnect? (y/n): y
Press “y” to exit the system. A confirmation screen displays:
Connection closed...
Press SPACE key to enter console mode configuration!


Model 2160 Series User Manual 6 • Contacting Patton for assistance
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems:
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Introduction 104

Model 2160 Series User Manual 6 • Contacting Patton for assistance
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 105


Model 2160 Series User Manual A • Compliance information
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reason- able protection from such interference in a commercial installation. However, there is no guarantee that inter- ference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equip- ment and receiver are on different branches).
We certify that the apparatus described above conforms to the requirements of Council Directive 2004/108/EC on the approximation of the laws of the member states relating to electromagnetic compatibility; and Council Directive 2006/95/EC on the approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.
D R M Green European Compliance Services Limited. Oakdene House, Oak Road, Watchfield, Swindon, Wilts SN6 8TD, UK
Compliance 107


Model 2160 Series User Manual B • Specifications
Line Modulation
TC-PAM 16
Ethernet Connector
4 x 8-position shielded RJ-45
Auto-sensing 10/100Base-TX with half or full-duplex operation
802.1d Transparent Bridging
2K MAC address learning bridge
IEEE 802.1q VLAN Tagging
Port Based VLAN, up to 4K VLANs
Traffic classification based on port/802.1p/DSCP (Differentiated Services Code Point )
WRR (Weighted Round Robin)/SPQ (Strict Priority Queing) scheduling algorithm

Model 2160 Series User Manual B • Specifications
CLI for local and console access; password protected;
SNMP v1/v2 (RFC 1157/1901/1905) agent and MIB (RFC 1213/1493)
EFM OAM (IEEE 802.3af)
Software upgradeable via web-browser/TFTP
Power, Alarm, Diagnostic, WAN Link (x4), Ethernet Link (x4), Ethernet 100M (x4)
7.67L x 1.89W x 6.61D in. (195L x 48H x 168D mm)
2.86 lbs (1300 g) without power supply
Web based GUI · Management Interface 110


Model 2160 Series User Manual C • Port pin-outs
This section provides pin-out information for the ports of the Model 2160.
8–RTS (N/C) 7–CTS (N/C) 6–TD 5–RD 4–SG 3–DTR 2–CD (N/C) 1–DSR
1 2 3 4 5 6 7 8
Pins 1 & 3 are connected together
Figure 68. EIA-561 (RJ-45 8-pin) port
Introduction 112

Model 2160 Series User Manual C • Port pin-outs
Table 34. RJ45 socket 10/100Base-T
2 TX-
3 RX+
6 RX-
Table 35. RJ45 socket CopperLink
5 TRD0-
3 TRD1+
6 TRD1-
7 TRD2+
8 TRD2-
1 TRD3+
2 TRD3-
Pin Signal · Pin Signal · Ethernet 113