Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 1 of the Patton electronic 2160 user manual — CopperLink™ Model 2160 Series Long Range Ethernet Extender
Page 1 · click to enlarge
Page 1

CopperLink™ Model 2160 Series Long Range Ethernet Extender

User Manual

Patton electronic 2160 — CopperLink™ Model 2160 Series Long Range Ethernet Extender diagram (page 1)
Fig. 1 · CopperLink™ Model 2160 Series Long Range Ethernet Ex…
Sales Office+1 (301) 975-1000 Technical Support: +1 (301) 975-1007
E-mailsupport@ patton.com
WWWwww.patton.com
Part Number07M2160-GS, Rev. D
RevisedFebruary 24, 2012

For Quick · Start Installation

Page 2 of the Patton electronic 2160 user manual
Page 2 · click to enlarge
Page 2

Patton Electronics Company, Inc.

7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

Tel+1 (301) 975-1000 Fax: +1 (301) 869-9293 Support: +1 (301) 975-1007
Webwww.patton.com E-mail: support@ patton.com

Trademark Statement The term CopperLink is a trademark of Patton Electronics Company. All other trade- marks presented in this document are the property of their respective owners.

Copyright © 2012, Patton Electronics Company. All rights reserved. The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.

Warranty Information Patton Electronics warrants all Model 2160 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.

This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warran- ties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

Page 3 of the Patton electronic 2160 user manual — Summary Table of Contents
Page 3 · click to enlarge
Page 3

Summary Table of Contents

1 General information 17

2 Applications overview 22

3 Hardware installation 27

4 Web configuration 33

5 Console and Telnet configuration 69

6 Contacting Patton for assistance 103

A Compliance information 106

B Specifications 108

C Port pin-outs 111

Page 4 of the Patton electronic 2160 user manual — Table of Contents
Page 4 · Contents
Contents

Contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 9 of the Patton electronic 2160 user manual — List of Figures
Page 9 · click to enlarge
Page 9

List of Figures

1 Model 2160 18 2 Model 2160 front panel LEDs 19 3 Model 2160 rear panel 20 4 Model 2160 application 23 5 Model 2160 connection diagram 29 6 Grounding stud 31 7 System login screen 36 8 Basic setup flowchart 36 9 Operation mode and Management port setup page 37 10 Basic DHCP setup 38 11 LAN setup page 39 12 Review and save basic setup changes 40 13 LINE page 41 14 VLAN page 43 15 VLAN Diagram 44 16 802.1Q Tag-Based VLAN page 45 17 VLAN tag field 46 18 802.1Q VLAN diagram 47 19 Port-Based VLAN page 48 20 QoS page 49 21 QoS - Port Based Priority page 50 22 WRR Example 51 23 WFQ Example 51 24 BE Example 51 25 SP Example 52 26 QoS - Port Based Priority - WRR Configuration 52 27 QoS - Port Based Priority - WFQ Configuration 52 28 QoS - Port Based Priority Table 52 29 QoS - VLAN Tag Priority page 53 30 IEEE 802.1Q Tagged Frame for Ethernet 53 31 QoS - Tag Based Priority - WRR Configuration 54 32 QoS - Tag Based Priority - WFQ Configuration 54 33 QoS - VLAN Tag Priority Table 55 34 Service by WRR 56 35 DSCP field 56 36 QoS - IP DSCP Priority - WRR Configuration 57 37 QoS - IP DSCP Priority - WFQ Configuration 57 38 QoS - IP DSCP Priority page 58 39 DSCP Configuration Example 58 40 Rate Limit page 59 41 Flow Control page 59 42 LINE Status page (8-wire model shown) 60 43 Management Status page 60 44 LAN Status page 61 45 Performance Status page 61 46 Security Administration page 62 47 Model 2160 configuration modes 62

Page 10 of the Patton electronic 2160 user manual — List of Figures
Page 10 · click to enlarge
Page 10

Model 2160 Series User Manual

48 Remote Management Host section 63 49 SNMP Administration page 64 50 SNMP community pool configuration 64 51 Trap host pool configuration 65 52 Remote Syslog configuration page 65 53 System Information page 66 54 Configuration Tool page 66 55 Upgrade page 67 56 Logout page 68 57 Restart page 68 58 Restart page 68 59 Console/Telnet Menu 72 60 Menu tree for authorized users 73 61 Main screen for authorized users 74 62 Main menu for unauthorized users 74 63 Main screen for unauthorized users 74 64 LINE Status 90 65 Interface Status 91 66 System Information 92 67 Show Script 92 68 EIA-561 (RJ-45 8-pin) port 112

Page 11 of the Patton electronic 2160 user manual — List of Tables
Page 11 · click to enlarge
Page 11

List of Tables

1 General conventions 16 2 Front panel LEDs 19 3 Port descriptions 20 4 Distance Chart 2160 Series – Auto Mode 24 5 Distance Chart Model 2160 Series – Optimal Mode 25 6 Distance Chart Model 2160 Series – TCPAM-128 26 7 Line Type Chart 41 8 Main Rate Chart 42 9 VLAN Tag Priority Levels 54 10 WRR Scheduling Configuration Example Values 55 11 Default SNMP Communities 64 12 Console settings 71 13 Interface commands 71 14 Enable Command Menu 75 15 Line Options 76 16 Line Type Chart 77 17 Main Rate Table 77 18 LAN Options 78 19 VLAN Mode Options 79 20 802.1Q VLAN Options 81 21 VLAN Mode Options 82 22 Queue Schedule Types 82 23 Queue Schedule Options 83 24 Egress Rate (N Value) 84 25 Port-Based Priority QoS Options 84 26 VLAN Tag Priority Levels 85 27 VLAN Tag Priority QoS Options 85 28 Rate Options 86 29 IP DSCP Priority QoS Options 86 30 DHCP Command Descriptions 88 31 Status Command Menu 90 32 Interface Statistics 91 33 Show Command Menu 92 34 RJ45 socket 10/100Base-T 113 35 RJ45 socket CopperLink 113

Page 12 of the Patton electronic 2160 user manual — Structure
Page 12 · click to enlarge
Page 12

About this guide

This guide describes the CopperLink™ Model 2160 hardware, installation and basic configuration.

Audience

This guide is intended for the following users:

  • Operators
  • Installers
  • Maintenance technicians

Structure

This guide contains the following chapters and appendices:

  • Chapter 1, “General information” on page 17 provides information about Ethernet Extender features and capabilities
  • Chapter 2, “Applications overview” on page 22 describes the typical application for the Model 2160
  • Chapter 3, “Hardware installation” on page 27 provides quick start hardware installation procedures
  • Chapter 4, “Web configuration” on page 33 describes configuring the Model 2160 via the web interface
  • Chapter 5, “Console and Telnet configuration” on page 69 describes configuring the Model 2160 via the console interface
  • Chapter 6, “Contacting Patton for assistance” on page 103 contains information on contacting Patton technical support for assistance
  • Appendix A, “Compliance information” on page 106 contains compliance information for the Model 2160
  • Appendix B, “Specifications” on page 108 contains for the specifications for the Model 2160
  • Appendix C, “Port pin-outs” on page 111 contains pinouts for the Model 2160 ports

For best results, read the contents of this guide before you install the Model 2160.

Page 13 of the Patton electronic 2160 user manual — WARNING
Page 13 · click to enlarge
Page 13

Model 2160 Series User Manual About this guide

Precautions

The alert symbol and IMPORTANT heading calls attention to important information.

IMPORTANT

The alert symbol and CAUTION heading indicate a potential hazard. Strictly follow the instructions to avoid property damage.

CAUTION

The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.

CAUTION

The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.

WARNING

The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.

WARNING

Page 14 of the Patton electronic 2160 user manual — WARNING
Page 14 · click to enlarge
Page 14

Model 2160 Series User Manual About this guide

Safety when working with electricity

The Model 2160 contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service per- sonnel. Opening the Model 2160 case will void the warranty.

WARNING

Mains Voltage: Do not open the case the when the power cord is attached. Line voltages are present within the power supply when the power cords are connected. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and pro- tected by a circuit breaker.

WARNING

For AC powered units, ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground.

WARNING

Hazardous network voltages are present in WAN ports regardless of whether power to the Model 2160 is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the Model 2160 first.

WARNING

Do not work on the system or connect or disconnect cables during periods of lightning activity.

WARNING

In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.

Page 15 of the Patton electronic 2160 user manual — CAUTION
Page 15 · click to enlarge
Page 15

Model 2160 Series User Manual About this guide

Preventing Electrostatic Discharge Damage When starting to install interface cards place the interface card on its shielded plastic bag if you lay it on your bench.

Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures.

Always follow ESD prevention procedures when removing and replacing cards.

Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.

CAUTION

To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is avail- able, ground yourself by touching the metal part of the chassis.

General observations • Clean the case with a soft slightly moist anti-static cloth

  • Place the unit on a flat surface and ensure free air circulation
  • Avoid exposing the unit to direct sunlight and other heat sources
  • Protect the unit from moisture, vapors, and corrosive liquid s
Page 16 of the Patton electronic 2160 user manual — Typographical conventions used in this document
Page 16 · click to enlarge
Page 16

Model 2160 Series User Manual About this guide

Typographical conventions used in this document

This section describes the typographical conventions and terms used in this guide.

General conventions The procedures described in this manual use the following text conventions:

Table 1. General conventions

Garamond blue type Indicates a cross-reference hyperlink that points to a figure, graphic, table, or sec- tion heading. Clicking on the hyperlink jumps you to the reference. When you have finished reviewing the reference, click on the Go to Previous View

button in the Adobe® Acrobat® Reader toolbar to return to your starting point.

Futura bold type Commands and keywords are in boldface font.

Futura bold-italic type Parts of commands, which are related to elements already named by the user, are in boldface italic font.

Italicized Futura type Variables for which you supply values are in italic font Futura type Indicates the names of fields or windows.

Garamond bold type Indicates the names of command buttons that execute an action. < > Angle brackets indicate function and keyboard keys, such as , , , and so on.

[ ] Elements in square brackets are optional.

{a | b | c} Alternative but required keywords are grouped in braces ({ }) and are separated by vertical bars ( | )

blue screen Information you enter is in blue screen font.

screen Terminal sessions and information the system displays are in screen font.

node The leading IP address or nodename of a Model 2160 is substituted with node in boldface italic font.

# An hash sign at the beginning of a line indicates a comment line.

Convention Meaning

Page 17 of the Patton electronic 2160 user manual — Table of contents
Page 17 · click to enlarge
Page 17

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 18 of the Patton electronic 2160 user manual — Model 2160 overview
Page 18 · click to enlarge
Page 18

Model 2160 Series User Manual 1 • General information

Model 2160 overview

The Patton CopperLink™ Model 2160 simplifies and provides cost effective network extension by utilizing pre-existing twisted pair infrastructure enables service providers to offer broadband or data backhaul services to businesses, governments, and various institutions over existing last-mile, copper infrastructure. Today, more than ever, operators are finding the business case for leveraging their existing copper networks to be highly attractive from an ROI and initial investment perspective over fiber roll-outs.

Patton’s 2160 CopperLink Ethernet Extender incorporates multi-pair bonding to offer unmatched rate, reach and reliable Ethernet connectivity, providing symmetrical 22.8 Mbps of bandwidth over 4-pair (8-wire) at dis- tances up to 1.8 miles (2.9 km). The Model 2160 comes standard with a 4-port fast Ethernet switch with full QoS and CoS features. VLAN (802.1q) capabilities include 4 levels of priorities, traffic flow control, and rate control. These traffic management and QoS features enable service providers to provision for differentiated ser- vices and/or SLAs.

Patton electronic 2160 — Model 2160 overview diagram (page 18)
Fig. 2 · Model 2160 overview

Figure 1. Model 2160

The following base models are available:

  • 2160/2W/EUI: CopperLink Ethernet Extender (2-wire), 5.7 Mbps
  • 2161/4W/EUI: CopperLink Ethernet Extender (4-wire), 11.4 Mbps
  • 2162/8W/EUI: CopperLink Ethernet Extender (8-wire), 22.8 Mbps

Refer to Appendix B, “Specifications” on page 108 for a complete feature description of the Model 2160.

Model 2160 overview 18

Page 19 of the Patton electronic 2160 user manual — Model 2160 front panel
Page 19 · click to enlarge
Page 19

Model 2160 Series User Manual 1 • General information

Model 2160 front panel

LED descriptions The front panel LEDs display the status of the power, system, Ethernet ports, and Line port. Figure 2 shows the front panel LED indicators and table 2 provides a description of the LED indicators’ behavior.

Patton electronic 2160 — Model 2160 front panel diagram (page 19)
Fig. 3 · Model 2160 front panel

LINK 1 2 3 4 CopperLink™ 2160 Long Range Ethernet Extender

WAN(1-4) Line Connection LAN (1-4) Ethernet Link/Activity LAN (1-4) Ethernet Mode

Figure 2. Model 2160 front panel LEDs

Table 2. Front panel LEDs

Patton electronic 2160 — Model 2160 front panel diagram (page 19)
Fig. 4 · Model 2160 front panel

LAN port is on 100M mode LAN port is on 10M mode

Model 2160 front panel 19

Page 20 of the Patton electronic 2160 user manual — Model 2160 rear panel
Page 20 · click to enlarge
Page 20

Model 2160 Series User Manual 1 • General information

Model 2160 rear panel

Patton electronic 2160 — Model 2160 rear panel diagram (page 20)
Fig. 5 · Model 2160 rear panel

Port descriptions The CopperLink™ Model 2160 rear panel ports are shown in figure 3 and described in table 3.

Figure 3. Model 2160 rear panel

Table 3. Port descriptions

Patton electronic 2160 — Model 2160 rear panel diagram (page 20)
Fig. 6 · Model 2160 rear panel

Console (RS-232 control port) Used for service and maintenance, the Console port, an RS-232 RJ-45 connector with EIA-561 pinout, connects the router to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal). Asynchronous default data rate 9600 bps, hardware DSR and DTR signals for external modems are wired directly together internally

Reset Reset button for rebooting or loading factory default settings

LAN (LAN Ethernet Ports 1-4) 10/100Base-Tx full-/half-duplex, RJ-45, auto detection and fall- back, connects the unit to an Ethernet LAN.

Model 2160 rear panel 20

Page 21 of the Patton electronic 2160 user manual — Ground terminal
Page 21 · click to enlarge
Page 21

Model 2160 Series User Manual 1 • General information

Reset button • To restart the unit with the current startup configuration—Press for less than 1 second and release the Reset button. The Model 2160 will restart with the current startup configuration.

  • To restart the unit with factory default configuration—Press the Reset button for 5 seconds until the Power LED starts blinking. The unit will restart with factory default configuration.
  • To restart the unit in bootloader mode (to be used only by trained CopperLink technicians)—Start with the unit powered off. Press and hold the Reset button while applying power to the unit. Release the Reset button when the Power LED starts blinking so the unit will enter bootloader mode.

Ground terminal

The marked lug or terminal should be connected to the building protective earth bus.The func- tion of protective earth does not serve the purpose of providing protection against electrical shock, but instead enhances surge suppression on the lines for installations where suitable bonding facili- ties exist.The connector type is M3 machine screw.

Model 2160 rear panel 21

Page 22 of the Patton electronic 2160 user manual — Table of contents
Page 22 · click to enlarge
Page 22

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 23 of the Patton electronic 2160 user manual — Typical application
Page 23 · click to enlarge
Page 23

Model 2160 Series User Manual 2 • Applications overview

Introduction

The Patton CopperLink™ Model 2160 simplifies and provides cost effective network extension by utilizing pre-existing twisted pair infrastructure enables service providers to offer broadband or data backhaul services to businesses, governments, and various institutions over existing last-mile, copper infrastructure. Today, more than ever, operators are finding the business case for leveraging their existing copper networks to be highly attractive from an ROI and initial investment perspective over fiber roll-outs.

Typical application

Patton’s CopperLink Auto-Rate Ethernet Extenders are the perfect fit for simple, cost-effective high speed Ethernet Extension. They allow customers to take advantage of the existing copper infrastructure to connect remote LAN’s across distances and at speeds previously unthought-of. The auto-rate feature ensures the highest speed is achieved on each connection, and the plug-n-play operation ensures they are up and running in sec- onds. Add in the 4 x auto-sensing full/half duplex 10/100Base-TX Ethernet ports with the integrated crossover switch to make setup even easier. The value of these Ethernet Extenders can’t be beat!

  • Auto-Rate Feature—The advanced auto-rate algorithm automatically determines the best possible rate for each connection and sets up each extender without any need for user interface.
  • Plug-and-Play—Just unpack the extenders, plug them into each end of the extension, power them up, and they are up and running. It doesn’t get any easier!
  • High Speed/Long Reach—These Ethernet Extenders provide the best combination of speed and distance seen anywhere in the industry!
Patton electronic 2160 — Typical application diagram (page 23)
Fig. 7 · Typical application

Figure 4. Model 2160 application

Introduction 23

Page 24 of the Patton electronic 2160 user manual — Distance Chart 2160 Series – Auto Mode (TCPAM-32/16)
Page 24 · click to enlarge
Page 24

Model 2160 Series User Manual 2 • Applications overview

Distance charts

Distance Chart 2160 Series – Auto Mode (TCPAM-32/16)

Table 4. Distance Chart 2160 Series – Auto Mode

Patton electronic 2160 — Distance Chart 2160 Series – Auto Mode (TCPAM-32/16) diagram (page 24)
Fig. 8 · Distance Chart 2160 Series – Auto Mode (TCPAM-32/16)

2160 2-Wire 2161 4-Wire 2162 8-Wire 26 AWG/0.4mm 24 AWG/0.5mm 22 AWG/0.65mm

N = kbps kbps kbps kft km kft km kft km

3 192 384 768 17.0 5.2 21.5 6.6 27.5 8.4

4 256 512 1024 17.0 5.2 20.5 6.2 27.0 8.2

8 512 1024 2048 14.5 4.4 17.5 5.3 23.5 7.2

12 768 1536 3072 13.5 4.1 16.0 4.9 21.5 6.6

16 1024 2048 4096 12.5 3.8 15.0 4.6 20.0 6.1

20 1280 2560 5120 12.0 3.7 14.5 4.4 19.0 5.8

24 1536 3072 6144 11.5 3.5 14.0 4.3 18.5 5.6

32 2048 4096 8192 11.0 3.4 13.5 4.1 17.5 5.3

36 2304 4608 9216 11.0 3.4 13.0 4.0 17.0 5.2

60 3840 7680 15360 9.0 2.7 11.0 3.4 14.5 4.4

72 4608 9216 18432 8.5 2.6 10.0 3.0 13.5 4.1

89 5696 11392 22784 7.5 2.3 9.0 2.7 12.0 3.7

Distance charts 24

Page 25 of the Patton electronic 2160 user manual — Distance Chart 2160 Series – Optimal Mode (TCPAM-128)
Page 25 · click to enlarge
Page 25

Model 2160 Series User Manual 2 • Applications overview

Distance Chart 2160 Series – Optimal Mode (TCPAM-128)

Table 5. Distance Chart Model 2160 Series – Optimal Mode

Patton electronic 2160 — Distance Chart 2160 Series – Optimal Mode (TCPAM-128) diagram (page 25)
Fig. 9 · Distance Chart 2160 Series – Optimal Mode (TCPAM-128…

2160 2-Wire 2161 4-Wire 2162 8-Wire 26 AWG/0.4mm 24 AWG/0.5mm 22 AWG/0.65mm

N = kbps kbps kbps kft km kft km kft km

7 448 896 1792 20.0 6.1 24.0 7.3 31.0 9.4

8 512 1024 2048 19.0 5.8 23.0 7.0 30.0 9.1

10 640 1280 2560 18.0 5.5 20.5 6.2 28.0 8.5

11 704 1408 2816 17.0 5.2 19.0 5.8 26.5 8.1

16 1024 2048 4096 16.0 4.9 18.0 5.5 24.5 7.5

20 1280 2560 5120 15.0 4.6 17.0 5.2 23.0 7.0

22 1408 2816 5632 14.0 4.3 15.5 4.7 21.0 6.4

27 1728 3456 6912 13.0 4.0 14.5 4.4 20.0 6.1

34 2176 4352 8704 12.0 3.7 14.5 4.4 18.5 5.6

39 2496 4992 9987 11.0 3.4 13.0 4.0 17.0 5.2

44 2816 5362 11264 10.0 3.0 12.0 3.7 15.5 4.7

53 3392 6784 13568 9.0 2.7 10.5 3.2 13.5 4.1

73 4672 9344 18688 8.0 2.4 9.5 2.9 12.5 3.8

89 5696 11392 22784 7.0 2.1 8.5 2.6 10.5 3.2

110 7040 14080 28160 6.0 1.8 7.0 2.1 9.0 2.7

125 8000 16000 32000 5.0 1.5 6.0 1.8 7.5 2.3

152 9728 19456 38912 4.0 1.2 4.5 1.4 6.0 1.8

164 10496 20992 41984 3.0 0.9 3.5 1.1 4.5 1.4

198 12792 25584 51168 2.0 0.6 2.5 0.8 3.0 0.9

Distance charts 25

Page 26 of the Patton electronic 2160 user manual — Distance Chart 2160 Series – TCPAM-128
Page 26 · click to enlarge
Page 26

Model 2160 Series User Manual 2 • Applications overview

Distance Chart 2160 Series – TCPAM-128

Table 6. Distance Chart Model 2160 Series – TCPAM-128

Patton electronic 2160 — Distance Chart 2160 Series – TCPAM-128 diagram (page 26)
Fig. 10 · Distance Chart 2160 Series – TCPAM-128

2160 2-Wire 2161 4-Wire 2162 8-Wire 26 AWG/0.4mm 24 AWG/0.5mm 22 AWG/0.65mm

N = kbps kbps kbps kft km kft km kft km

5 320 640 1280 22.0 6.7 26.5 8.1 34 10.4

6 384 768 1536 21.0 6.4 25.5 7.8 32.5 9.9

8 512 1024 2048 20.0 6.1 24.0 7.3 31.0 9.4

9 576 1152 2304 19.0 5.8 23.0 7.0 29.5 9.0

9 576 1152 2304 18.0 5.5 21.5 6.6 27.5 8.4

12 768 1536 3072 17.0 5.2 20.5 6.2 26.5 8.1

16 1024 2048 4096 16.0 4.9 19.5 5.9 24.5 7.5

20 1280 2560 5120 15.0 4.6 18.0 5.5 23.0 7.0

22 1408 2816 5632 14.0 4.3 16.5 5.0 21.5 6.6

27 1728 3456 6912 13.0 4.0 15.7 4.8 20.0 6.1

34 2176 4352 8704 12.0 3.7 14.5 4.4 18.5 5.6

39 2496 4992 9984 11.0 3.4 13.0 4.0 17.0 5.2

45 2880 5760 11520 10.0 3.0 12.0 3.7 15.5 4.7

53 3392 6784 13568 9.0 2.7 10.5 3.2 13.5 4.1

74 4736 9472 18944 8.0 2.4 9.5 2.9 12.5 3.8

90 5760 11520 23040 7.0 2.1 8.5 2.6 10.5 3.2

112 7168 14336 28672 6.0 1.8 7.0 2.1 9.0 2.7

126 8064 16128 32256 5.0 1.5 6.0 1.8 7.5 2.3

152 9728 19456 38912 4.0 1.2 4.5 1.4 6.0 1.8

167 10688 21376 42752 3.0 0.9 3.5 1.1 4.5 1.4

198 12672 25344 50688 2.0 0.6 2.5 0.8 3.0 0.9

220 14072 28144 56288 1.0 0.3 1.0 0.3 1.5 0.5

239 15288 30576 61152 0.5 0.2 0.5 0.2 1.0 0.3

Distance charts 26

Page 27 of the Patton electronic 2160 user manual — Table of contents
Page 27 · click to enlarge
Page 27

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 28 of the Patton electronic 2160 user manual — Planning the installation
Page 28 · click to enlarge
Page 28

Model 2160 Series User Manual 3 • Hardware installation

Introduction

This chapter contains information for planning the installation of the Model 2160 with the following installa- tion procedures:

  • “Unpacking the Model 2160” on page 30 lists the contents of the shipping box
  • “Connecting cables” on page 30 describes how to install the port cables
  • “Grounding the Model 2160 and connecting power” on page 31 describes how to ground and connect the power source

Planning the installation

Before beginning the actual installation, we strongly recommend that you gather all the information you will need to install and set up the device.

  • Create a network diagram
  • Gather IP related information
  • Install the hardware and software needed to configure the Model 2160
  • Verify power source reliability

When you finish preparing for your installation, go to section “Installing the Model 2160” on page 30 to install the device.

Introduction 28

Page 29 of the Patton electronic 2160 user manual — Network diagram
Page 29 · click to enlarge
Page 29

Model 2160 Series User Manual 3 • Hardware installation

Network diagram Draw a network overview diagram that displays all neighboring IP nodes, connected elements and telephony components. Figure 5 shows possible network connections to the Model 2160.

Patton electronic 2160 — Network diagram diagram (page 29)
Fig. 11 · Network diagram

Figure 5. Model 2160 connection diagram

IP related information Before you can set up the basic IP connectivity for your Model 2160 series you should have the following information:

  • IP addresses used for Ethernet LAN and WAN ports
  • Subnet mask used for Ethernet LAN and WAN ports

You will need a PC (or equivalent) with a VT-100 emulation program (e.g. HyperTerminal) to configure the software on your Model 2160.

AC Power Mains If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery with large motors nearby, have a qualified professional test the power. Install a power conditioner if necessary. Refer to “Grounding the Model 2160 and connecting power” on page 31.

Patton electronic 2160 — Network diagram diagram (page 29)
Fig. 12 · Network diagram

The mains outlet that is utilized to power the equipment must be within 1 foot (3 meters) of the device and shall be easily accessible.

Planning the installation 29

Page 30 of the Patton electronic 2160 user manual — WARNING
Page 30 · click to enlarge
Page 30

Model 2160 Series User Manual 3 • Hardware installation

Location and mounting requirements The Model 2160 is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables. Additionally, you should consider the need to access the unit for future upgrades and maintenance.

This completes the planning phase for installation. The next section begins the installation procedures.

Installing the Model 2160

Unpacking the Model 2160 Inspect the shipping carton for external damage. Note any damage before removing the container contents. Report any equipment damage to the shipping carrier immediately for claim purposes. Save all packing mate- rial in case you need to return an item to the factory for servicing.

The Model 2160 comes with the following items:

  • Model 2160 Quick Start Guide
  • Model 2160
  • An RJ-45-to-RJ-45 cable for use with the console and Ethernet ports
  • A DB-9-to-RJ-45 (EIA-561) adapter for connecting a PC’s serial port to the Model 2160 console port

Connecting cables

The Interconnecting cables must be acceptable for external use and must be rated for the proper application with respect to volt- age, current, anticipated temperature, flammability, and mechanical serviceability.

CAUTION

1. Connect the Ethernet cable to the Management port. Model 2160 supports audi-MDIX switching so you may use a crossover or straight-through cable.
2. Connect one end of a phone cable to the LINE port and the other end of the cable to a wall jack.

Do not work on the system or connect or disconnect cables during periods of lightning activity.

WARNING

Installing the Model 2160 30

Page 31 of the Patton electronic 2160 user manual — IMPORTANT
Page 31 · click to enlarge
Page 31

Model 2160 Series User Manual 3 • Hardware installation

Grounding the Model 2160 and connecting power In connecting to the power source, it is important to establish a good grounding connection first, then the power connection. Do the following:

1. Assemble a ground wire using #10 AWG wire with green-colored insulation and two ring terminals. Make the wire long enough to reach one of the following earth ground sources:

– The building ground rod (generally located at the site’s main service entrance)

– A sprinkler system pipe

– A cold-water pipe

– Building structural steel

MGMT LINE

Figure 6. Grounding stud

2. Install the grounding wire between the grounding stud (see figure 6 ) and the grounding source.
3. Connect the power adapter to the DC 9V port on the Model 2160, and then connect to the power source.

Mains Voltage: Do not open the case the when the power cord is attached. Line voltages are present within the power supply when the power cords are connected. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and pro- tected by a circuit breaker.

WARNING

The Model 2160 is not shipped with power cables. For AC powered units, ensure that the power cable used meets all applicable standards for the coun- try in which it is to be installed, and that it is connected to a wall outlet which has earth ground.

WARNING

The power supply automatically adjusts to accept an input volt- age from 100 to 240 VAC(50/60 Hz).

IMPORTANT

Installing the Model 2160 31

Grounding stud

Page 32 of the Patton electronic 2160 user manual — Configuring the Model 2160
Page 32 · click to enlarge
Page 32

Model 2160 Series User Manual 3 • Hardware installation

Configuring the Model 2160

There are three different ways you can configure the Model 2160: the serial console, Telnet, or a web browser.

Web configuration requirements Make sure that the PC you use for configuration has an Ethernet adapter and TCP/IP installed.

The Model 2160 provides a browser interface that allows you to configure and manage the Ethernet Extender. After you set up the IP address for the 2160, you can access the Ethernet Extender's Web interface applications directly in your browser by entering the IP address. You can then use your Web browser to manage and config- ure the unit from a PC.

Console configuration requirements To configure the Model 2160 through the serial console, you can directly connect a terminal or a PC equipped with a terminal-emulation program (such as Hyper Terminal) to the Ethernet Extender's console port.

Use the supplied serial cable (RJ-45 to DB9F) to connect the Model 2160 to a PC. After marking the connec- tion, configure the terminal-emulation program to use the following parameters:

  • 9600 bps
  • 8 data bits
  • no parity
  • 1 stop bit

Telnet configuration requirements Make sure that the PC you use for configuration has an Ethernet adapter and TCP/IP installed. The Model 2160 supports Telnet for remote configuration. The command is “telnet 192.168.1.1” . When prompted for the username and password for remote login, use admin for username and admin for password. All display screens are the same as serial console configuration.

The default IP address is 192.168.1.1, but you may change the IP address for your application.

Configuring the Model 2160 32

Page 33 of the Patton electronic 2160 user manual — Table of contents
Page 33 · click to enlarge
Page 33

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 34 of the Patton electronic 2160 user manual — Table of contents
Page 34 · click to enlarge
Page 34

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 35 of the Patton electronic 2160 user manual — Setting Up the WMI
Page 35 · click to enlarge
Page 35

Introduction

The Model 2160 provides a browser interface that allows you to configure and manage the Ethernet Extender. Make sure that the PC you use for configuration has an Ethernet adapter and TCP/IP installed. After you set up the IP address for the 2160, you can access the Ethernet Extender's Web interface applications directly in your browser by entering the IP address. You can then use your Web browser to manage and configure the unit from a PC.

Setting Up the WMI

This section introduces the configuration and functions of the Web Management Interface (WMI). The WMI is an HTML-based management interface that allows you to easily set-up and manage the Model 2160.

The Model 2160 offers all monitoring and management features that allow users to manage this Model 2160 form anywhere on the network through a standard browser such as Internet Explorer.

TCP/IP setup When DHCP is enabled, the Model 2160 acts as a DHCP server in your network. The Model 2160 will auto- matically assign IP address for the management port connection.

To set up TCP/IP on a Windows PC:

1. Click the Start button. Select the Control Panel .
2. Double-click on the Network icon.
3. In the Configuration window, select the TCP/IP protocol line that has been associated with your network card and then click the property icon.
4. Click on the IP address tab and select Obtain IP address automatically . Click OK .

System Login You may use a web browser such as Internet Explorer on your PC to connect the Model 2160. Type “http://” and the IP address like as “http://192.168.1.1”.

The default IP address and sub net-mask of the Management port of the Model 2160 are 192.168.1.1 and 255.255.255.0. If DHCP is disabled, your PC can set the same net-mask such as 192.168.1.x where x is a number from 2 to 254.

Introduction 35

Page 36 of the Patton electronic 2160 user manual — Basic Configuration Options
Page 36 · click to enlarge
Page 36

Type the default User name root and default Password root and then click OK. For system security, you should change the user name and password after initial onfiguration.

Patton electronic 2160 — Basic Configuration Options diagram (page 36)
Fig. 13 · Basic Configuration Options

Figure 7. System login screen

Basic Configuration Options

This section contains information for setting up the operation mode and Management port IP, DHCP server, and LAN via the WMI. Figure 8 shows a flowchart demonstrating basic setup via the WMI for the Model 2160.

Patton electronic 2160 — Basic Configuration Options diagram (page 36)
Fig. 14 · Basic Configuration Options

Figure 8. Basic setup flowchart

Basic Configuration Options 36

Page 37 of the Patton electronic 2160 user manual — – IP: 192.168.1.1
Page 37 · click to enlarge
Page 37

Operation mode and Management port To configure the operation mode and Management port in the WMI:

1. From the main menu, click Basic to display the basic installation page.
Patton electronic 2160 — Operation mode and Management port diagram (page 37)
Fig. 15 · Operation mode and Management port

Figure 9. Operation mode and Management port setup page

2. For Operation Mode , select the radio button for CPE (Customer Premises Equipment) or CO (Central Office). When using a “LAN to LAN” connection, one side must be set as CO and the other side must be set as CPE.
3. Enter information for the Management port. The Model 2160 requires an IP address to be managed over the network. The factory default IP address is 192.168.1.1 . The subnet mask specifies the network number portion of an IP address. The factory default subnet mask is 255.255.255.0 . You can configure another IP address and a different subnet mask for management purposes.

– IP: 192.168.1.1

– Subnet Mask255.255.255.0
– Host NameSOHO

Some ISP providers require the Host Name as identification. You may check with your ISP to see if your Internet service has been configured with a host name. In most cases, you can ignore this field.

4. Select an option for Trigger DHCP Service . If you don't need the DHCP service, select Disable .
5. Click Next to commit your changes and continue to the DHCP Server page (see “DHCP server” on page 37).

DHCP server Dynamic Host Configuration Protocol (DHCP) is a communication protocol that allows network adminis- trators to manage and automate the assignment of Internet Protocol (IP) addresses in an organization's net- work. Each machine that can connect to the Internet needs a unique IP address. When an organization sets up the users with a connection to the Internet, an IP address must be assigned to each machine.

Without DHCP, the IP address must be entered manually at each computer. If computers move to another location in another part of the network, a new IP address must be entered. DHCP lets a network administrator

Basic Configuration Options 37

Page 38 of the Patton electronic 2160 user manual — Operation mode and Management port
Page 38 · click to enlarge
Page 38

supervise and distribute IP addresses from a central point and automatically sends a new IP address when a computer is plugged into a different place in the network. The embedded DHCP server assigns network con- figuration information to 253 users (max) accessing the Internet in the same time. For example, if the LAN IP address is 192.168.0.1, the IP range of the LAN is 192.168.0.2 to 192.168.0.254.

To set up the DHCP Server for the Model 2160:

1. Click on Basic from the main menu, set up the Operation Mode and Management port , then click Next to reach the DHCP Server page.
2. The DHCP server assigns the IP from the Start IP Address to the End IP Address . The legal IP address range is from 0 to 255, but 0 is reserved as the network name and 255 is reserved for broadcast. This implies that the legal IP address range is from 1 to 254. That means you cannot assign an IP greater than 254 or less than 1.
3. A Lease Time of 72 hours indicates that the DHCP server will reassign IP information every 72 hours., which is the default value for the Model 2160. You can set up the Lease Time for a range from 1 to 720 hours according to your application.
4. If you assign a fixed IP address to a device while using DHCP, you must enter the device's MAC address in the Table of Fixed DHCP Host Entries .
5. Click Next to commit your changes and continue to the LAN page (see “LAN” on page 39).
Patton electronic 2160 — Operation mode and Management port diagram (page 38)
Fig. 16 · Operation mode and Management port

Figure 10. Basic DHCP setup

Basic Configuration Options 38

Page 39 of the Patton electronic 2160 user manual — LAN
Page 39 · click to enlarge
Page 39

LAN To configure LAN settings through the WMI:

1. Click on Basic from the main menu. Set up the Operation Mode and Management port , then click Next . Set up the DHCP Server , then click Next to reach the LAN page.
Patton electronic 2160 — LAN diagram (page 39)
Fig. 17

Figure 11. LAN setup page

2. Choose an option for the LAN Type . If you select Disable or Dynamic IP , click Next at the bottom of the screen to save your changes. If you select Static IP , you can enter information for IP, Subnet Mask, Gateway and DNS Server's IP.
3. If you select Static IP as the LAN Type , enter details in the Static IP section. The default values for Static IP are:
– IP Address192.168.2.1
– Subnet Mask255.255.255.0
– Gateway0.0.0.0
– DNS Server 1168.95.1.1
– DNS Server 2168.95.192.1
4. Click Next to commit your changes and continue to the Review page (see “Review and save basic setup changes” on page 40).

Basic Configuration Options 39

Page 40 of the Patton electronic 2160 user manual — Review and save basic setup changes
Page 40 · click to enlarge
Page 40

Review and save basic setup changes 1. Once you have entered information on the pages for Operation Mode and Management Port, DHCP Server, and LAN, the Basic Setup Review page will display to confirm your changes.

Patton electronic 2160 — Review and save basic setup changes diagram (page 40)
Fig. 18 · Review and save basic setup changes

Figure 12. Review and save basic setup changes

2. Look over the Review page to confirm the desired settings.
3. Click Restart to reboot the Model 2160 with the new settings.
4. Click Continue to configure other options.

Basic Configuration Options 40

Page 41 of the Patton electronic 2160 user manual — 2160 2-wire model •
Page 41 · click to enlarge
Page 41

Advanced Configuration Options

This section contains information for setting up advanced options for the Model 2160 via the WMI. Advanced setup contains Model 2160 Line, VLAN, QoS and Rate Control parameters.

LINE Click on LINE under Advanced on the main menu to reach the LINE advanced configuration page. You can setup the Line Type (number of wires), Annex Type, TCPAM Type, Main Rate, SNR Margin, and Line Probe settings for LINE parameters.

Patton electronic 2160 — Advanced Configuration Options diagram (page 41)
Fig. 19 · Advanced Configuration Options

Figure 13. LINE page

Line Type Select the line type for your model from the Link drop-down list. Line type means how many wires you want to use on the line side. For example, you can select 2-wire, 4-wire or 8-wire line type for the 8-wire model.

Table 7. Line Type Chart

2160 2-wire model •

  • 2161 4-wire model
  • 2162 8-wire model

Annex Type Select the appropriate Annex type from the drop-down list. Annex AF describes the transmission and perfor- mance requirements for North America. Annex BG describes performance and transmission requirements for Europe.

Advanced Configuration Options 41

Show 4 more labels / short text on this page
Line Type · 2-wire 4-wire 8-wire · Model · Type
Page 42 of the Patton electronic 2160 user manual — TCPAM-32
Page 42 · click to enlarge
Page 42

TCPAM Type TCPAM (Trellis Coded Pulse Amplitude Modulation) is the standard used for line coding. Select the TCPAM type from the drop-down list. Auto is the default option for TCPAM. You can also manually set the TCPAM type.

Main Rate Select the line rate for your model from the Main Rate drop-down list. The main rate is the multiple of 64kbps, 128kbps, or 256kpbs- depending on your model type. Use Table 8 to determine the best main rate for your model.

Table 8. Main Rate Chart

Model Type Multiple TCPAM-16

TCPAM-32

TCPAM-128

2160 2-wire model 64 192–3840 768–5696 128–15296

2161 4-wire model 128 384–7680 1536–11392 256–30592

2162 8-wire model 256 768–15360 3072–22784 512–61184

SNR Margin Select the desired SNR Margin value from the drop-down list. SNR margin is an index of line connection quality. You can see the actual SNR margin in STATUS. You will experience better line connection quality for larger SNR margin values.

For example, if you set the SNR margin is 5, the LINE connection will drop and reconnect when the SNR margin is lower than 5. On the other hand, the device will reduce the line rate and reconnect for better line connection quality. You may select the SNR margin from the range -10 to 21.

Line Probe For adaptive mode applications, set the Line Probe to Enable. The Model 2160 will adapt the data rate accord- ing to the line status. The screen will prompt the parameters that will be written in NVRAM. Check the parameters before writing in NVRAM.

For all other applications, set the Line Probe to Disable.

Click Restart to reboot the Model 2160 with the new settings. Click Continue to configure other options.

Advanced Configuration Options 42

= 3–60 · = 12–89 · = 2–239

Page 43 of the Patton electronic 2160 user manual — VLAN
Page 43 · click to enlarge
Page 43

VLAN Click on VLAN under Advanced on the main menu to reach the VLAN advanced configuration page.

Patton electronic 2160 — VLAN diagram (page 43)
Fig. 20

Figure 14. VLAN page

VLAN (Virtual Local Area Network) allows a physical network to be partitioned into multiple logical net- works. Devices on a logical network belong to one group. A device can belong to more than one group. With VLAN, a device cannot directly talk to or hear from devices that are not in the same group.

With MTU (Multi-Tenant Unit) applications, VLAN is vital in providing isolation and security among the subscribers. When properly configured, VLAN prevents one subscriber from accessing the network resources of another on the same LAN.

VLAN also increases network performance by limiting broadcasts to a smaller and more manageable logical broadcast domain. In traditional switched environments, all broadcast packets go to each every individual port. With VLAN, all broadcasts are confined to a specific broadcast domain.

You can select from two types of VLAN: 802.1Q Tag-Based VLAN and Port-Based VLAN. The VLAN Setup screen changes depending on whether you choose 802.1Q Tag-Based VLAN type or Port Based VLAN type. The IEEE 802.1Q defines the operation of VLAN bridges that permit the definition, operation, and adminis- tration of VLAN topologies within a bridged LAN infrastructure.

Figure 15 on page 44 shows a diagram of possible VLAN connections.

Advanced Configuration Options 43

Page 44 of the Patton electronic 2160 user manual — VLAN
Page 44 · click to enlarge
Page 44
Patton electronic 2160 — VLAN diagram (page 44)
Fig. 21

LINK 1 2 3 4 CopperLink“2160 Long Range Ethernet Extender

Figure 15. VLAN Diagram

Advanced Configuration Options 44

Page 45 of the Patton electronic 2160 user manual — 802.1Q Tag-Based VLAN
Page 45 · click to enlarge
Page 45

802.1Q Tag-Based VLAN Click on VLAN under Advanced on the main menu to reach the VLAN advanced configuration page. Then, select the radio button for 802.1Q Tag-Based VLAN to display the configuration options.

Patton electronic 2160 — 802.1Q Tag-Based VLAN diagram (page 45)
Fig. 22 · 802.1Q Tag-Based VLAN

Figure 16. 802.1Q Tag-Based VLAN page

  • VID (Virtual LAN ID): A number to identify the VLAN segment. Select from 1 to 4094.
  • PVID (Port VID): An untagged member of the default VLAN. Select from 1 to 4094.
  • Link Type: Select from Access or Trunk . Access means the port can receive or send untagged packets. Trunk means that the port can receive or send tagged packets.

In 802.1q, the VLAN information is written into the Ethernet packet itself. Each packet carries a VLAN ID (Virtual LAN ID) called a tag. This tag allows VLANs to be configured across multiple switches.

When using 802.1q, four bytes are added to the Ethernet frame, and 12 bits are used for the VLAN ID. Theo- retically, there can be up to 4096 VLANs per network.

An Ethernet packet that contains a VLAN ID is called a tagged packet. An Ethernet packet without a VLAN ID is called an untagged packet. Typically, all packets leave untagged, unless tagged by the adapter prior to arriving at the switch port.

Egress and Ingress Rules. Egress rules determine which frames can be transmitted out of a port, based on the Egress List of the associated VLAN. Each VLAN has an Egress List that specifies the ports out of which frames can be forwarded, and specifies whether the frames will be transmitted as tagged or untagged frames.

Ingress rules are a means of filtering out undesired traffic on a port. When Ingress Filtering is enabled, a port determines if a frame can be processed based on whether the port is on the Egress List of the VLAN associated with the frame.

When an untagged packet arrives at the switch port, the switch will write a VLAN ID into the header of the frame according to the PVID (port VLAN) definition. Typically, most switches today have all ports set to a default PVID of 1. When a tagged frame arrives at a switch port, the tag is respected.

A VID defines the member of a port group. A packet can only travel inside a member port when the member port is part of a VID port group. Different VID groups are not visible to one another.

Advanced Configuration Options 45

Page 46 of the Patton electronic 2160 user manual — 802.1Q Tag-Based VLAN
Page 46 · click to enlarge
Page 46

Tag-Based VLAN Overview. Figure 17 shows the breakdown of the VLAN tag field.

Patton electronic 2160 — 802.1Q Tag-Based VLAN diagram (page 46)
Fig. 23 · 802.1Q Tag-Based VLAN

Figure 17. VLAN tag field

The Tag Control Information (TCI) section of a VLAN tag includes information on the user Priority level, the Canonical Format Indicator (CFI) and VLAN ID (VID).

  • Tag Protocol Identifier (TPID) is a defined value of 8100 in hex. When a frame has the EtherType equal to 8100, this frame carries the tag IEEE 802.1Q / 802.1P.
  • Priority defines the priority level for different classes of traffic. There are 8 possible priority levels, with 0 being the lowest priority level and 7 being the highest level. IEEE 802.1P defines the operation for these 3 user priority bits.
  • Canonical Format Indicator (CFI) is always set to zero for Ethernet switches. CFI is used for compatibility reasons between an Ethernet-type network and Token Ring-type network. If a frame received at an Ethernet port has a CFI set to 1, then that frame should not be forwarded as it is to an untagged port.
  • VLAN ID (VID) is the unique identification number of the VLAN, which is used by the standard 802.1Q. It has 12 bits and allows the identification of 4096 (212) VLANs. Of the 4096 possible VIDs, a VID of 0 is used to identify priority frames and the value 4095 (FFF) is reserved, so the maximum possible VLAN configurations are 4,094.

The Model 2160 initially configures one VLAN by default, VID=1. A port such as LAN1–4, line or sniffing can have only one Port VID (PVID), but can have as many VID groups as the Model 2160 has memory in its VLAN table to store them.

Advanced Configuration Options 46

Page 47 of the Patton electronic 2160 user manual — 802.1Q Tag-Based VLAN
Page 47 · click to enlarge
Page 47

Ports in the same VLAN group share the same frame broadcast domin thus increase network performance through reduced boardcast traffic. You can modify VLAN groups at any time by adding, moving or changing ports without any re-cabling.

Patton electronic 2160 — 802.1Q Tag-Based VLAN diagram (page 47)
Fig. 24 · 802.1Q Tag-Based VLAN

LINK 1 2 3 4 CopperLink“2160 Long Range Ethernet Extender

LINK 1 2 3 4 CopperLink“2160 Long Range Ethernet Extender

Figure 18. 802.1Q VLAN diagram

Configuring 802.1Q VLAN Tagging. Before enabling VLANs for the Model 2160, you must first assign each port to the VLAN group(s) in which it will participate. By default all ports are assigned to VLAN1 as untagged ports. Add a port as a tagged port if you want it to carry traffic for one or more VLANs, and any intermediate network devices or the host at the other end of the connection supports VLANs. Then, assign ports on the other VLAN-aware network devices along the path that will carry this traffic to the same VLAN(s), either manually or dynamically using Generic VLAN Routing Protocol (GVRP). However, if you want a port on this Model 2160 to participate in one or more VLANs, but none of the intermediate network devices nor the host at the other end of the connection supports VLANs, then you should add this port to the VLAN as an untagged port.

  • VLAN Classification - When the Model 2160 receives a frame, it classifies the frame in one of two ways. If the frame is untagged, the Model 2160 assigns the frame to an associated VLAN (based on the default VLAN ID of the receiving port). But if the frame is tagged, the Model 2160 uses the tagged VLAN ID to identify the port broadcast domain of the frame.
  • Port Overlapping - You can use port overlapping to allow access to commonly shared network resources among different VLAN groups, such as file servers or printers.

Advanced Configuration Options 47

Page 48 of the Patton electronic 2160 user manual — Port-Based VLAN
Page 48 · click to enlarge
Page 48
  • Untagged VLANs - Untagged (or static) VLANs are typically used to reduce broadcast traffic and to increase security. A group of network users assigned to a VLAN form a broadcast domain that is separate from other VLANs configured on the Model 2160. Packets are forwarded only between ports that are designated for the same VLAN. Untagged VLANs can be used to manually isolate user groups or subnets.
  • Port VID (PVID) - A PVID is a VLAN ID assigned to untagged frames received on the interface. (Default: 1). If an interface is not a member of VLAN 1 and you assign its PVID to this VLAN, the interface will automatically be added to VLAN 1 as an untagged member. For all other VLANs, an interface must first be configured as an untagged member before you can assign its PVID to that group.
  • Link Type - The Link Type determines the types of frames the port can accept. Access means the port can only receive or send untagged frame types. Trunk means that the port can only receive or send tagged frame types.

Port-Based VLAN Click on VLAN under Advanced on the main menu to reach the VLAN advanced configuration page. Then, select the radio button for Port-Based VLAN to display the configuration options.

Patton electronic 2160 — Port-Based VLAN diagram (page 48)
Fig. 25 · Port-Based VLAN

Figure 19. Port-Based VLAN page

Port-Based VLANs are VLANs where the packet forwarding decision is based on the destination MAC address and its associated port. When using port-based VLAN, the port is assigned to a specific VLAN independent of the user or system attached to the port. This means all users attached to the port should be members in the same VLAN. The network administrator typically performs the VLAN assignment. The port configuration is static and cannot be automatically changed to another VLAN without manual reconfiguration.

As with other VLAN approaches, the packets forwarded using this method do not leak into other VLAN domains on the network. After a port has been assigned to a VLAN, the port cannot send to or receive from devices in another VLAN.

Advanced Configuration Options 48

Page 49 of the Patton electronic 2160 user manual — Quality of Service (QoS)
Page 49 · click to enlarge
Page 49

Quality of Service (QoS) Quality of Service (QoS) refers to both a network's ability to deliver data with minimum delay, and the net- working methods used to control the use of bandwidth. Without QoS, all traffic date is equally likely to be dropped when the network is congested. This can cause a reduction in network performance and mark the net- work inadequate for time-critical application such as video-on-demand.

Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page.

Patton electronic 2160 — Quality of Service (QoS) diagram (page 49)
Fig. 26 · Quality of Service (QoS)

Figure 20. QoS page

QoS (Quality of Service) is used to decide which devices can get priorities to pass though the Model 2160 once the bandwidth is exhausted or fully saturated.

There are three types of QoS priority modes: Port Based Priority, VLAN Tag Priority and IP DSCP Priority. You can also disable the QoS function.

Advanced Configuration Options 49

Page 50 of the Patton electronic 2160 user manual — Port Based Priority
Page 50 · click to enlarge
Page 50

Port Based Priority Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page. Then, select the radio button for Port Based Priority to display the configuration options.

Patton electronic 2160 — Port Based Priority diagram (page 50)
Fig. 27 · Port Based Priority

Figure 21. QoS - Port Based Priority page

Select the ports that the port-based priority rule should be applied. There are six ports to choose from: LAN1, LAN2, LAN3, LAN4, DSL and Sniffing.

The common setting tables are:

WRR configuration: Each queue type can setup the queue weight from 1 to 15.

WFQ configuration: Each ports and their queue type can set the bandwidth.

Scheduling Configuration. The 2160 provides three combinations of four commonly used techniques: Type 1, Type 2 and Type 3. Select a type in the Scheduling Configuration section, then provide details in the corre- sponding table.

If you select Type 1, refer to “WRR Configuration” on page 52.

If you select Type 2 or Type 3, refer to “WFQ Configuration” on page 52.

The Queue types are Weight Round Robin (WRR), Weighted Fair Queuing (WFQ), Best Effort (BE) and Strictly Priority (SP). Refer to the following page for more information on how each Queue Type operates.

Advanced Configuration Options 50

Page 51 of the Patton electronic 2160 user manual — Port Based Priority
Page 51 · click to enlarge
Page 51
  • Weight Round Robin (WRR): All received packets will be stored into Queue 1, Queue 2, Queue 3, and Queue 4. Assign a weight value for each queue. Then, WRR will re-assemble all packets from the four queues based on the weight assignments.
Patton electronic 2160 — Port Based Priority diagram (page 51)
Fig. 28 · Port Based Priority

Figure 22. WRR Example

For example, Figure 22 shows the weight value of each queue, ranging from 4, 2, 5, and 1. When the 2160 starts to process all of the packets in these queues with WRR, a new packet develops based on the weight assignments. Then, the 2160 sends out the new packet.

  • Weighted Fair Queuing (WFQ): WFQ is a generalization of processor sharing, which allows several sessions to share the same link. Refer to “WFQ Configuration” on page 52 to assign the data size of each queue that can be accepted by each port.
Patton electronic 2160 — Port Based Priority diagram (page 51)
Fig. 29 · Port Based Priority

Figure 23. WFQ Example

  • Best Effort (BE): The BE Queue Type is used for data applications that have low priority or the potential to delay. BE does not use traffic priority or weight assignments, therefore BE is not recommended for high priority data, such as video or voice.
Patton electronic 2160 — Port Based Priority diagram (page 51)
Fig. 30 · Port Based Priority

Figure 24. BE Example

Advanced Configuration Options 51

Page 52 of the Patton electronic 2160 user manual — Port Based Priority
Page 52 · click to enlarge
Page 52
  • Strictly Priority (SP): The SP Queue Type uses queues that are based on priority only. SP transmits the highest priority queue first, then the next highest priority queue, and so on. However, if there is always some content in the highest priority queue, then the other packets in the rest of queues will not be sent until the highest priority queue is empty. The SP algorithm is preferred when the received packets contain some high priority data, such as voice and video.
Patton electronic 2160 — Port Based Priority diagram (page 52)
Fig. 31 · Port Based Priority

Figure 25. SP Example

WRR Configuration. If you selected Type 1 in the Scheduling Configuration section, then provide infor- mation for the WRR table. Assign a weight value (from 1 to 15) to determine the priority for each queue.

Patton electronic 2160 — Port Based Priority diagram (page 52)
Fig. 32 · Port Based Priority

Figure 26. QoS - Port Based Priority - WRR Configuration

WFQ Configuration. If you selected Type 2 or Type 3 in the Scheduling Configuration section, then pro- vide information for the WFQ table. Assign the bandwidth for each queue in each port.

Patton electronic 2160 — Port Based Priority diagram (page 52)
Fig. 33 · Port Based Priority

Figure 27. QoS - Port Based Priority - WFQ Configuration

Port-Based Priority Table. For the last step, assign queues to their corresponding ports: LAN 1-4, DSL and Sniffing.

Patton electronic 2160 — Port Based Priority diagram (page 52)
Fig. 34 · Port Based Priority

Figure 28. QoS - Port Based Priority Table

Advanced Configuration Options 52

Page 53 of the Patton electronic 2160 user manual — VLAN Tag Priority
Page 53 · click to enlarge
Page 53

VLAN Tag Priority Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page. Then, select the radio button for VLAN Tag Priority to display the configuration options.

Patton electronic 2160 — VLAN Tag Priority diagram (page 53)
Fig. 35 · VLAN Tag Priority

Figure 29. QoS - VLAN Tag Priority page

VLAN Tag Priority uses the tag field information which has been inserted into an Ethernet frame. If a port has an 802.1Q-compliant device attached (such as this Ethernet Extender), these tagged frames can carry VLAN membership information.

Patton electronic 2160 — VLAN Tag Priority diagram (page 53)
Fig. 36 · VLAN Tag Priority

Figure 30. IEEE 802.1Q Tagged Frame for Ethernet

Priority defines the user priority level for different classes of traffic. There are 8 possible priority levels, with 0 being the lowest priority level and 7 being the highest level. Each Priority level can be set queue from 0 to 3.

Advanced Configuration Options 53

Page 54 of the Patton electronic 2160 user manual — VLAN Tag Priority
Page 54 · click to enlarge
Page 54

Table 9. VLAN Tag Priority Levels

Priority Level Traffic Type

0 (default) Best Effort

5 Video, less than 100 milliseconds latency and jitter

6 Voice, less than 10 milliseconds latency and jitter

Scheduling Configuration. The 2160 provides three combinations of four commonly used techniques: Type 1, Type 2 and Type 3. Select a type in the Scheduling Configuration section, then provide details in the corre- sponding table.

If you select Type 1, refer to “WRR Configuration” on page 54.

If you select Type 2 or Type 3, refer to “WFQ Configuration” on page 54.

WRR Configuration. If you selected Type 1 in the Scheduling Configuration section, then provide infor- mation for the WRR table. Assign a weight value (from 1 to 15) to determine the priority for each queue. “Weight” determines how important the queue is; therefore, 15 is the most important queue and 0 is the least important queue.

Figure 31. QoS - Tag Based Priority - WRR Configuration

WFQ Configuration. If you selected Type 2 or Type 3 in the Scheduling Configuration section, then pro- vide information for the WFQ table. Assign the bandwidth for each queue in each port.

Figure 32. QoS - Tag Based Priority - WFQ Configuration

Advanced Configuration Options 54

Show 5 more labels / short text on this page
1 Background · 2 Spare · 3 Excellent Effort · 4 Controlled Load · 7 Network Control
Page 55 of the Patton electronic 2160 user manual — VLAN Tag Priority
Page 55 · click to enlarge
Page 55

VLAN Tag Priority Table. Select a packet with an assigned priority to correspond with each queue.

Patton electronic 2160 — VLAN Tag Priority diagram (page 55)
Fig. 37 · VLAN Tag Priority

Figure 33. QoS - VLAN Tag Priority Table

Configuration Example. As an example, you can set the Model 2160 to use Weighted Round-Robin (WRR) queuing that specifies a relative weight of each queue. WRR uses a predefined relative weight for each queue that determines the percentage of service time to provide each queue before moving on to the next queue. This prevents the head-of-line blocking that can occur with strict priority queuing.

Table 10. WRR Scheduling Configuration Example Values

Queue 0 1 2 3

Type 1 WRR

Weight 1 2 4 8

For this example, set up the WRR (Type 1) to share bandwidth by using scheduling weights 1, 2, 4 and 8 for queues 0 through 3 respectively.

Priority 0 1 2 3 4 5 6 7

Queue 1 0 0 1 2 2 3 3

According to the two tables above, the QoS values map to the Egress Queues as follows:

Queue 0 1 2 3

Weight 2 15 7 8

Priority 0 1 2 3 4 5 6 7

Queue 0 0 2 2 3 3 1 1

This example displays that:

  • Packets with priority 0 and priority 1 go to Queue 0.
  • Packets with priority 2 and priority 3 go to Queue 2.
  • Packets with priority 4 and priority 5 go to Queue 3.
  • Packets with priority 6 and priority 7 go to Queue 1.
  • When, data flow traffic is jammed:

- Queue 1 Packets will go first because weight is equal to 15 (the biggest value).

- Queue 3 Packets will go next because the weight is the second largest value.

- Queue 2 Packets are the next after Queue 3 Packets.

- Queue 0 Packets are the last one to send.

Advanced Configuration Options 55

Page 56 of the Patton electronic 2160 user manual — IP DSCP Priority
Page 56 · click to enlarge
Page 56

4,5 Queue 2 1,2 Queue 0

4,5 Queue 2 0,3 Queue 1

4,5 Queue 2 4,5 Queue 2

Figure 34. Service by WRR

IP DSCP Priority Differentiated Services Code Point (DSCP) is the 6-bit field in the header of IP packets, and it is for packet classification purposes. The DSCP algorithm is based on IP DSCP fields in the IP header. There are 64 levels of priority degrees (0 to 63). Figure 35 shows the DS field:

Patton electronic 2160 — IP DSCP Priority diagram (page 56)
Fig. 38 · IP DSCP Priority

Figure 35. DSCP field

Advanced Configuration Options 56

6,7 Queue 3

Page 57 of the Patton electronic 2160 user manual — IP DSCP Priority
Page 57 · click to enlarge
Page 57

Click on QoS under Advanced on the main menu to reach the QoS advanced configuration page. Then, select the radio button for IP DSCP Priority to display the configuration options.

Patton electronic 2160 — IP DSCP Priority diagram (page 57)
Fig. 39 · IP DSCP Priority

Scheduling Configuration. The 2160 provides three combinations of four commonly used techniques: Type 1, Type 2 and Type 3. Select a type in the Scheduling Configuration section, then provide details in the corre- sponding table.

WRR Configuration. If you selected Type 1 in the Scheduling Configuration section, then provide infor- mation for the WRR table. Assign a weight value (from 1 to 15) to determine the priority for each queue. “Weight” determines how important the queue is; therefore, 15 is the most important queue and 0 is the least important queue.

Patton electronic 2160 — IP DSCP Priority diagram (page 57)
Fig. 40 · IP DSCP Priority

Figure 36. QoS - IP DSCP Priority - WRR Configuration

WFQ Configuration. If you selected Type 2 or Type 3 in the Scheduling Configuration section, then pro- vide information for the WFQ table. Assign the bandwidth for each queue in each port.

Patton electronic 2160 — IP DSCP Priority diagram (page 57)
Fig. 41 · IP DSCP Priority

Figure 37. QoS - IP DSCP Priority - WFQ Configuration

Advanced Configuration Options 57

Page 58 of the Patton electronic 2160 user manual — IP DSCP Priority
Page 58 · click to enlarge
Page 58

IP DSCP Priority Table. Select the queue for each DSCP level. Each DSCP value (from 0 to 63) is mapped to a Queue value (from 0 to 3) from the drop-down list The number 0 represents the lowest priority and num- ber 3 represents the highest priority and according various queuing strategies to tailor performance to require- ments.

Patton electronic 2160 — IP DSCP Priority diagram (page 58)
Fig. 42 · IP DSCP Priority

Figure 38. QoS - IP DSCP Priority page

IP DSCP Configuration Example. In this example, the selected operation is Type 3. For the Type 3 combination, set up Queue 1 and Queue 2 for WFQ configuration.

Patton electronic 2160 — IP DSCP Priority diagram (page 58)
Fig. 43 · IP DSCP Priority

For this example, assume the following actions:

  • Assign DSCP 1 to Queue 0.
  • Assign DSCP 14 to Queue 1.
  • Assign DSCP 34 to Queue 2.
  • Assign DSCP 55 to Queue 3.

Figure 39 shows the results of the configuration for the LAN 1 port.

Patton electronic 2160 — IP DSCP Priority diagram (page 58)
Fig. 44 · IP DSCP Priority

Figure 39. DSCP Configuration Example

Advanced Configuration Options 58

Page 59 of the Patton electronic 2160 user manual — Rate Limit
Page 59 · click to enlarge
Page 59

Rate Limit Click on Rate Limit under Advanced on the main menu to reach the Rate Control configuration page.

Patton electronic 2160 — Rate Limit diagram (page 59)
Fig. 45 · Rate Limit

Figure 40. Rate Limit page

Limiting bandwidth to specific users and ports helps control network congestion, ensure high performance, create efficient networks, and prevent a small number of users from monopolizing network bandwidth.

Rate limiting control can be used to intelligently manage bandwidth allocation in the networking. It can pre- vent one user or device from dominating the available network bandwidth, and it allows IT managers to allo- cate greater bandwidth to the departments and applications that need it.

You can set up the data rate limit on each port from 0 to 22. The data rates available are 00 (No limit), and the Ingress Rate x 1024kbps. The default setting is No limit on each port.

Flow Control Click on Flow Control under Advanced on the main menu to reach the Flow Control configuration page. When the Flow Control option is enabled, the 2160 controls the packet size.

Patton electronic 2160 — Rate Limit diagram (page 59)
Fig. 46 · Rate Limit

Figure 41. Flow Control page

Advanced Configuration Options 59

Page 60 of the Patton electronic 2160 user manual — Status Options
Page 60 · click to enlarge
Page 60

Status Options

This section contains information for monitoring status options for the Model 2160 via the WMI. The Status menu contains Line, Management, LAN, Performance and Syslog parameters.

LINE Status The LINE Status includes information for the run-time device status, mode, Bitrate and Performance infor- mation such as SNR margin, atteunation and CRC error count.

Patton electronic 2160 — Status Options diagram (page 60)
Fig. 47 · Status Options

Figure 42. LINE Status page (8-wire model shown)

If two Model 2160s have been linked together, you can view their run-time line rate status and performance information from this screen. If you want to clear the performance data, click Clear CRC Error.

Management Status The Management Status page displays information about the Management port interface. You can view the general status of the Management interface and DHCP client table.

Patton electronic 2160 — Status Options diagram (page 60)
Fig. 48 · Status Options

Figure 43. Management Status page

Status Options 60

Page 61 of the Patton electronic 2160 user manual — LAN Status
Page 61 · click to enlarge
Page 61

LAN Status The LAN Status page displays information about a LAN port. The system will allow you to select which LAN port to view.

Patton electronic 2160 — LAN Status diagram (page 61)
Fig. 49 · LAN Status

Figure 44. LAN Status page

Performance Status The Performance Status page displays information about the uptime and errors of the system.

Patton electronic 2160 — LAN Status diagram (page 61)
Fig. 50 · LAN Status

Figure 45. Performance Status page

Status Options 61

Page 62 of the Patton electronic 2160 user manual — Administration Options
Page 62 · click to enlarge
Page 62

Administration Options

This section allows you to configure administration options for Security, Simple Network Management Proto- col (SNMP) and Remote System Log.

Security Administration For system security, you should change the default user name and password during initial setup. Otherwise, unauthorized persons can access the Model 2160 and change the parameters. Click Security in the Administra- tion menu to set up the parameters.

Patton electronic 2160 — Administration Options diagram (page 62)
Fig. 51 · Administration Options

Figure 46. Security Administration page

User Profiles For better security, change the Supervisor ID and Supervisor Password for the Model 2160. If you don't set them, all users will be able to access the Model 2160 using the default Supervisor ID and Supervisor Password ,which is root.

You can authorize five legal users to access the Model 2160 via telnet or console only. There are two UI modes, menu driven mode and command mode to configure the Model 2160. The default user name and Password are admin. There are two UI modes, the WMI and the Telnet/Console mode to set up the Model 2160.

Telnet Console Mode Web Browser Mode

Only available functionsPing, View Status, Configuration

All functions are available

All functions are available

Figure 47. Model 2160 configuration modes

Show 8 more labels / short text on this page
Supervisor ID · User Name · Password · Supervisor Password · Supervisor Password · Exit · Logout · Administration Options 62
Page 63 of the Patton electronic 2160 user manual — Remote Management Hosts
Page 63 · click to enlarge
Page 63

Remote Management Hosts The Remote Management Host section of the Security Administration page enables you to set up the legal IP addresses from which authorized persons can configure the Model 2160. This is the most secure way for the network administrator to set up the legal address of configuration.

Patton electronic 2160 — Remote Management Hosts diagram (page 63)
Fig. 52 · Remote Management Hosts

Figure 48. Remote Management Host section

A configuration of 0.0.0.0 will allow all hosts on Internet or LAN to access the Model 2160. If you leave the trusted host list completely blank, you will block all PCs on the WAN from accessing the Model 2160. On the other hand, only PCs in the LAN can access the Model 2160. If you type the exact IP address in the filed, only that host can access the Model 2160.

Click Finish to commit your changes. The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to reboot the Model 2160 with the new settings. Click Continue to con- figure other options.

SNMP Administration Simple Network Management Protocol (SNMP) provides for the exchange of messages between a network management client and a network management agent for remote management of network nodes. These mes- sages contain requests to get and set variables that exist in network nodes in order to obtain statistics, set con- figuration parameters, and monitor network events. SNMP communications can occur over the LAN or WAN connection.

The Model 2160 can generate SNMP traps to indicate alarm conditions, and it relies on SNMP community strings to implement SNMP security. This Model 2160 support both MIB I and MIB II.

Administration Options 63

Page 64 of the Patton electronic 2160 user manual — Community Pool
Page 64 · click to enlarge
Page 64

Click SNMP in the Administration menu to set up the parameters.

Patton electronic 2160 — Community Pool diagram (page 64)
Fig. 53 · Community Pool

Figure 49. SNMP Administration page

Community Pool An SNMP community is a group of devices and management stations running SNMP. It helps define where information is sent. The community name is used to identify the group. A SNMP device or agent may belong to more than one community. It will not request information from management stations that do not belong to one of its communities.

Table 11. Default SNMP Communities

Click Modify to set up community pools.

Patton electronic 2160 — Community Pool diagram (page 64)
Fig. 54 · Community Pool

Figure 50. SNMP community pool configuration

In the table of the current community pool, you can set up access:

  • Status: Enable –Turn on the SNMP function; Disable –Turn off the SNMP function
  • Access Right: Deny –Restrict all access; Read –Read-only access; Write –Read/write access
  • Community: The password for write access.
Show 4 more labels / short text on this page
Access Right Community · Read public · Write private · Administration Options 64
Page 65 of the Patton electronic 2160 user manual — Trap Host Pool
Page 65 · click to enlarge
Page 65

After configuring the community pool, click Finish. The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to reboot the Model 2160 with the new settings. Click Continue to configure other options.

Trap Host Pool In the table of current trap host pool, you can set up the trap host. SNMP trap is an informational message sent from an SNMP agent to a manager. It is a management station (SNMP application) that receives traps. If you don’t define a trap host pool, then no traps are issued.

Click Modify to set up the trap host pool.

Patton electronic 2160 — Trap Host Pool diagram (page 65)
Fig. 55 · Trap Host Pool

Figure 51. Trap host pool configuration

  • Version: Select version for trap host. (Version 1 is for SNMPv1; Version 2 for SNMPv2; Disable–Turn off)
  • IP Address: Enter the trap host IP address
  • Community: Enter the community password.

Click OK to finish the setup. The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to reboot the Model 2160 with the new settings. Click Continue to configure other options.

Remote Syslog Click Remote Syslog in the Administration menu to send the log information of the 2160 to a remote site.

Patton electronic 2160 — Trap Host Pool diagram (page 65)
Fig. 56 · Trap Host Pool

Figure 52. Remote Syslog configuration page

  • Service Setup
- ModeEnable/Disable the remote syslog service
- FacilitySelect from LOCAL_USE0 to LOCAL_USE9 and SEC_AUTH
  • Protocol Setup
- Server IPThe IP address of the remote management server, where the logs will be sent
- PortThe port number of the specific IP address

Administration Options 65

Page 66 of the Patton electronic 2160 user manual — Utility Options
Page 66 · click to enlarge
Page 66

Utility Options

This section allows you to manage utility options for the Model 2160, including system information, the con- figuration tool, upgrade information, log out of the system, and restart the system.

System Information To review system information, click System Info in the Utility menu.

Patton electronic 2160 — Utility Options diagram (page 66)
Fig. 57 · Utility Options

Figure 53. System Information page

You can check the MCSV, Software Version, Chipset, Firmware Version, Host Name and System Up Time. The System Up Time item let you know how long the Model 2160 has been running since powering up.

Configuration Tool The configuration tool has three options: Load Factory Default, Restore Configuration, and Backup Config- uration. Click Config Tool in the Utility menu.

Patton electronic 2160 — Utility Options diagram (page 66)
Fig. 58 · Utility Options

Figure 54. Configuration Tool page

Select the desired configuration function, then click Finish.

  • Load Factory Default: The system will load the factory default parameters for the Model 2160.

Utility Options 66

Page 67 of the Patton electronic 2160 user manual — Upgrade
Page 67 · click to enlarge
Page 67
  • Restore Configuration: Use this option to recover the backup configuration easily. Click Finish after selecting Restore Configuration . Browse to the backup file then click Finish again. The Model 2160 will automatically restore the saved configuration.
  • Backup Configuration: After you configure the Model 2160 with your desired settings, you can use the Backup Configuration option to save your Model 2160 parameters in the PC. Select the Backup Configuration and then click Finish . Browse to the backup directory, and click Finish again. The Model 2160 will automatically save the configuration.

Upgrade You can update the firmware of Model 2160 using the Upgrade function. Click Upgrade in the Utility menu.

Patton electronic 2160 — Upgrade diagram (page 67)
Fig. 59 · Upgrade

Figure 55. Upgrade page

Type the path and file name of the Firmware file you wish to upload to the Model 2160 in text box. Or, you can also click Browse to locate the file. Click OK to begin the upgrade process. The system will reboot auto- matically after finishing. (Firmware upgrades will only take effect after the system reboots).

After the firmware upgrade process is complete, click System Info in the Utility menu to verify your current firmware version number.

Utility Options 67

Page 68 of the Patton electronic 2160 user manual — Logout
Page 68 · click to enlarge
Page 68

Logout To exit the Model 2160 Web Management Interface securely, click Logout in the Utility menu. You have to log in with your password again after you log out. This is recommended after you finish a management session for security reasons.

Patton electronic 2160 — Logout diagram (page 68)
Fig. 60 · Logout

Figure 56. Logout page

Restart To reboot the Model 2160, click Restart in the Utility menu, then click the Restart button.

Patton electronic 2160 — Logout diagram (page 68)
Fig. 61 · Logout

Figure 57. Restart page

The following screen displays:

Patton electronic 2160 — Logout diagram (page 68)
Fig. 62 · Logout

Figure 58. Restart page

Utility Options 68

Page 69 of the Patton electronic 2160 user manual — Table of contents
Page 69 · click to enlarge
Page 69

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 70 of the Patton electronic 2160 user manual — Table of contents
Page 70 · click to enlarge
Page 70

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 71 of the Patton electronic 2160 user manual — Introduction
Page 71 · click to enlarge
Page 71

Introduction

This chapter provides information for configuring the Model 2160 by using the serial console with Telnet.

Log in to the console interface The console port is a RJ-48C connector that provides a connection to a PC for monitoring and configuring the Model 2160. Use the supplied serial cable with a female DB-9 connector to connect to the serial port of PC, and connect the RJ-48C module jack connector to the Model 2160's console port. Start your terminal emula- tion program (such as Hyper Terminal) and configure the communication parameters. Use the settings shown in Table 12 to log into the console:

Table 12. Console settings

After you enter the settings for the console, press the spacebar until the login screen appears. When you see the login screen, you can log on to the Model 2160. Enter admin for both the User Name and Password.

Log in using Telnet The Model 2160 also supports Telnet for remote management. Connect the Ethernet cable to the Manage- ment port of Model 2160 to your computer. The Management LED on the front panel of the Model 2160 will light up. Start your Telnet client with VT100 terminal emulation and connect to the management IP of the Model 2160. Wait for the login prompt to display. Enter your user name and password. When you see the login screen, you can log on to the Model 2160. Enter admin for both the User Name and Password.

Interface commands Before changing the configuration, familiarize yourself with the operations list in the following table:

Table 13. Interface commands

or I Move to the field above in the same level menu.

or K Move to field below in the same level menu.

or J Move back to the previous menu.

or L or [ENTER] Move forward to the submenu.

[HOME] or U Move to the first field. [END] or O Move to the last field. [TAB] Choose another parameter. Ctrl + C Quit configuring the item. Ctrl +Q Access help.

Show 8 more labels / short text on this page
Parameter Value · Baud rate 9600 · Data Bits 8 · Parity Check None · Stop Bits 1 · Flow-control None · Keystroke Description · Introduction 71
Page 72 of the Patton electronic 2160 user manual — Window structure
Page 72 · click to enlarge
Page 72

The Model 2160 uses a menu-driven interface for serial console and Telnet management. This interface dis- plays all available commands for configuring the Ethernet Extender.

The following figure shows an example of the menu-driven interface. In the menu, scroll up/down by pressing the I / K keys. Select one command by pressing the L key. Go back to a higher level of the menu by pressing the J key. You can also scroll to the top/bottom with the U/O keys.

For example, to show the system information, log on to the Model 2160. Press the K key twice and select the show command with the L key. Select the system command in the submenu. The system will display general information. You may also use the Enter key to select a command.

Patton electronic 2160 — Window structure diagram (page 72)
Fig. 63 · Window structure

Figure 59. Console/Telnet Menu

Window structure From top to bottom, the window is divided into four parts:

  • Product name: LINE Bridge
  • Menu field: The menu tree prompts on this field. Symbol “>>” indicates the cursor place.
  • Configuration field: Configure the parameters in this field. < parameter > indicates the parameters you can choose and < more…> indicates that there are more options in the submenu.
  • Footer: Operation commands for help

Introduction 72

Page 73 of the Patton electronic 2160 user manual — Main Menu Tree
Page 73 · click to enlarge
Page 73

Main Menu Tree

The commands available in the main menu tree depend on if you have logged in using a supervisor password (authorized user) or not (unauthorized user). An authorized user can access all of the configuration commands in the subdirectories using the enable command. Unauthorized users cannot change any configurations but can view the status and information for the Model 2160. They may also use the ping command to check the Model 2160’s connection.

Menu tree for authorized users Authorized users may log into the Model 2160 with a supervisor password to obtain access to all of the config- uration commands.

Patton electronic 2160 — Main Menu Tree diagram (page 73)
Fig. 64 · Main Menu Tree

Figure 60. Menu tree for authorized users

Main Menu Tree 73

Page 74 of the Patton electronic 2160 user manual — Menu tree for unauthorized users
Page 74 · click to enlarge
Page 74
Patton electronic 2160 — Menu tree for unauthorized users diagram (page 74)
Fig. 65 · Menu tree for unauthorized users

Figure 61. Main screen for authorized users

Menu tree for unauthorized users Unauthorized users may access the following configuration commands for the Model 2160.

Patton electronic 2160 — Menu tree for unauthorized users diagram (page 74)
Fig. 66 · Menu tree for unauthorized users

Figure 62. Main menu for unauthorized users

Patton electronic 2160 — Menu tree for unauthorized users diagram (page 74)
Fig. 67 · Menu tree for unauthorized users

Figure 63. Main screen for unauthorized users

Main Menu Tree 74

Page 75 of the Patton electronic 2160 user manual — Enable Command Menu
Page 75 · click to enlarge
Page 75

Enable Command Menu

The enable command menu lists commands for setting up the Model 2160. Move the cursor “ >>” to enable and press Enter. Type the supervisor password, which is root.

Commandenable <CR>

Message: Please input the following information.

Supervisor password****

In the enable sub menu, you can set up management features and upgrade software, back up the system config- uration and restore the system configuration via utility tools.

To save your changes, you must write the new configuration to NVRAM and reboot the Model 2160 to work with the new settings.

When you first log in to the Model 2160 with the supervisor password, the main menu displays:

>> enable Modify command privilege

status Show running system status

show View system configuration

write Update flash configuration

reboot Reset and boot system

ping Packet internet groper command

admin Setup management features

utility TFTP upgrade utility

Table 14 explains the commands available in the main menu:

Table 14. Enable Command Menu

enable Change the configuration and write changes to nonvolatile RAM (NVRAM).

setup Initially configure the Model 2160.

status View the status of the Model 2160

show Show the system and configuration

write Update flash configuration. After you have completed all desired changes, make sure to write the new configuration to NVRAM. Use the write command to save your changes and reboot the system or all of your changes will not take effect.

reboot Reset and reboot system. After you have completed all desired changes, make sure to write the new configuration to NVRAM. Use the reboot command to restart the system or all of your changes will not take effect.

ping Check the connection to the Model 2160

admin Set up advanced management features

utility Upgrade software and backup/restore the current configuration

exit Log out of the system

Enable Command Menu 75

Show 4 more labels / short text on this page
---------------------------------------------------------------------- · setup Configure system · exit Quit system · Command Description
Page 76 of the Patton electronic 2160 user manual — Setup Command Menu
Page 76 · click to enlarge
Page 76

Setup Command Menu

The setup command menu lists commands for initially configuring the Model 2160. Move the cursor “ >>” to setup in the main menu and press Enter.

When you enter the setup command, the following menu displays:

>> line Configure line parameters

lan Configure LAN interface profile

vlan Configure virtual LAN parameters

qos Configure Quality of Service parameters

rate Configure Rate Control parameters

Configure management interface profile

dhcp Configure DHCP parameters

dns_proxy Configure DNS proxy parameters

hostname Configure local host name

default Restore factory default settings

Line The line command menu lists commands for setting up the line port. Move the cursor “ >>” to line in the setup menu and press Enter. The following menu displays:

>> mode Configure line mode

link Configure line link

annex Configure line annex type

tcpam Configure line TCPAM type

maxMainRate Configure line max main data rate

snrMargin Configure line SNR margin

lineProbe Configure line line probe

clear Clear current CRC error count

Table 15 shows the options available within the line command menu:

Table 15. Line Options

Mode F STU-C F STU-R

Link Type F 2-wire F 4-wire F 8-wire

Annex F AF F BG

TCPAM F Auto F TCPAM-16 F TCPAM-32 F TCPAM-64

Max Main Rate (3–89)

Line Probe F Disable F Enable

Setup Command Menu 76

Manage- ment · Menu Options · SNR Margin (-10–21)

Page 77 of the Patton electronic 2160 user manual — TCPAM-32
Page 77 · click to enlarge
Page 77

Mode There are two types of Line mode:

  • STU-C : Central Office (CO) terminal
  • STU-R: Customer Premise Equipment (CPE)

Link Select the line type for your model. Line type means how many wires you want to use on the CopperLink con- nection. For example, you can select 2-wire, 4-wire or 8-wire line type for the 8-wire model.

Table 16. Line Type Chart

2-wire model •

  • 4-wire model
  • 8-wire model

Annex Type Enter the appropriate Annex type. Annex AF describes the transmission and performance requirements for North America. Annex BG describes performance and transmission requirements for Europe.

TCPAM Type TCPAM (Trellis Coded Pulse Amplitude Modulation) is the standard used for line coding. Select the TCPAM type. Auto is the default option for TCPAM.

Maximum Main Rate Select the line rate for your model. The main rate is the multiple of 64kbps, 128kbps, or 256kbps- depending on your model type. Use Table 17 to determine the best main rate for your model.

Table 17. Main Rate Table

Model Type Multiple TCPAM-16

TCPAM-32

TCPAM-128

2160 2-wire model 64 192–3840 768–5696 128–15296

2161 4-wire model 128 384–7680 1536–11392 256–30592

2162 8-wire model 256 768–15360 3072–22784 512–61184

SNR Margin SNR margin is an index of line connection quality. Generally, you won’t need to change the SNR Margin. You can view the actual SNR margin in status command menu.You will experience better line connection quality for larger SNR margin values.

For example, if you set the SNR margin ias 5, the line connection will drop and reconnect when the SNR mar- gin is lower than 5. On the other hand, the device will reduce the line rate and reconnect for better line con- nection quality. You may select the SNR margin from the range -10 to 21.

Setup Command Menu 77

Show 7 more labels / short text on this page
Line Type · 2-wire 4-wire 8-wire · Model · Type · = 3–60 · = 12–89 · = 2–239
Page 78 of the Patton electronic 2160 user manual — Line Probe
Page 78 · click to enlarge
Page 78

Line Probe For adaptive mode applications, set the Line Probe to Enable. The Model 2160 will adapt the data rate accord- ing to the line status. For all other applications, set the Line Probe to Disable.

Clear Use the clear command to reset the CRC error count.

LAN The lan command menu lists commands for setting up the LAN ports. Move the cursor “ >>” to lan in the setup menu and press Enter.

Commandsetup lan <1~1>

Message: Please input the following information.

Interface number <1~1>1

The default interface number is 1.

You can configure the Link type, LAN IP address and subnet mask for the LAN interface.

>> link_type Configure Link type

address LAN address and subnet mask

Table 18 shows the options available within the lan command menu:

Table 18. LAN Options

Link Type F Disable F Dynamic F Static

Commandsetup lan 1 link_type <Disable|Dynamic|Static>

Message: Please input the following information.

Link type (TAB Select) :

Select the lan 1 link_type as Disable, Dynamic or Static. Then, select address from the lan menu:

Commandsetup lan 1 address <ip> <netmask>

Message: Please input the following information.

IP address (ENTER for default) :

Subnet mask (ENTER for default) :

Set the LAN IP address and subnet mask. The default IP Address is 192.168.2.1 and the default subnet mask is 255.255.255.0.

Setup Command Menu 78

Show 6 more labels / short text on this page
----------------------------------------------------------------------------- · Menu Options · IP Address · Subnet Mask · ----------------------------------------------------------------------------- · -----------------------------------------------------------------------------
Page 79 of the Patton electronic 2160 user manual — VLAN
Page 79 · click to enlarge
Page 79

VLAN Virtual LAN (VLAN) is defined as a group of devices on one or more LANs that are configured so that they can communicate as if they were attached to the same wire, when in fact they are located on a number of differ- ent LAN segments. Because VLAN is based on logical instead of physical connections, it is extremely flexible.

You can setup the Virtual LAN (VLAN) parameters in VLAN command. The Model 2160 supports VLAN- to-PVC only for bridge mode operation, i.e., the VLAN spreads over both the CO and CPE sides, where there is no layer 3 routing involved. The unit supports up to 8 active VLANs with shared VLAN learning (SVL) bridge out of 4096 possible VLANs specified in IEEE 802.1Q.

The vlan command menu lists commands for setting up the line port. Move the cursor “ >>” to vlan in the setup menu and press Enter. The following menu displays:

>> mode Trigger virtual LAN function

modify Modify virtual LAN table

pvid Modify port default VID

link_mode Modify port link type

list Show VLAN configuration

To activate the VLAN function, move the cursor “ >> “ to mode and press Enter. The products support two types of VLAN: 802.1Q and Port-Based.

802.1Q defines the operation of VLAN bridges that permit the definition, operation, and administration of VLAN topologies within a bridged LAN infrastructure. Port-Based VLANs are VLANs where the packet for- warding decision is based on the destination MAC address and its associated port.

Mode You can choose from two types of VLANs: 802.1Q Tag-Based VLAN or Port Based VLAN. If you are not going to use the VLAN function, set this option to Disable.

Commandsetup vlan mode <Disable|8021Q|Port>

Message: Please input the following information.

Trigger VLAN function (TAB Select) :

Table 19 shows the options available within the VLAN mode command menu:

Table 19. VLAN Mode Options

VLAN Mode F Disable F 802.1Q Tag VLAN F Port-Based VLAN

Setup Command Menu 79

· Menu Options

Page 80 of the Patton electronic 2160 user manual — VLAN
Page 80 · click to enlarge
Page 80

802.1Q VLAN. To modify the VLAN rule, move the cursor to modify and press Enter.

Commandsetup vlan modify <1~8> <0~4094> <string>

Message: Please input the following information.

VLAN table entry index <1~8>1

VID value (ENTER for default) : 10

VLAN port membership (ENTER for default) :

The VLAN Port membership ris represented with 1 or 0. VLAN port membership is a 6-digit binary number in which bit 0 to bits 5 represent LAN1 to LAN4, line and Sniffing ports respectively.

For example: [ setup vlan modify 1 10 111111 ] means use index as 1 , VID = 10 and all six ports are the same membership (VLAN ID=10).

Use the pvid command to change the member port to untagged members:

Commandsetup vlan pvid <1~6> <1~4094>

Message: Please input the following information.

Port index :

VID value (ENTER for default) :

PVID (Port VID) is an untagged member from 1 to 4094 for the default VLAN.

For example:

[ set vlan pvid 1 100]

[ set vlan pvid 2 100]

[ set vlan pvid 3 100]

[ set vlan pvid 4 100]

[ set vlan pvid 5 100]

[ set vlan pvid 6 100]

This example shows that all untagged members of all ports all have the same membership (VLAN ID=100).

To modify the link type of the port, move the cursor to link_mode and press Enter. There are two types of link: access and trunk. A Trunk link will send the tagged packet form the port. An Access link will send an untagged packet from the port. The port index 1 to 4 represents LAN ports. Index 5 represents line, and index 6 represents Sniffing.

Setup Command Menu 80

·

Page 81 of the Patton electronic 2160 user manual — VLAN
Page 81 · click to enlarge
Page 81
Commandsetup vlan link_mode <1~6> <Access|Trunk>

Message: Please input the following information.

Port index <1~6>1

Port link type (TAB Select) :

Table 20 shows the options available within the 802.1Q Tag VLAN command menu:

Access The port can receive or send untagged packets.

Trunk The port can receive or send tagged packets.

Table 20. 802.1Q VLAN Options

1 2 3 4 5 6

No. VID LAN1 LAN2 LAN3 LAN4 Line Sniffing 1 2 3 4 5 6 7 8 PVID Link Type F Access

Port-Based VLAN. With port-based VLAN, the port is assigned to a specific VLAN independent of the user or system attached to the port. This means all users attached to the port should be members in the same VLAN. The network administrator typically performs the VLAN assignment. The port configuration is static and cannot be automatically changed to another VLAN without manual reconfiguration.

You can set up Port-Based VLAN using the method for 802.11Q. However, VID , PVID or link type do not matter for Port-Based VLAN. Use the list command to check the status of the VLAN.

VLAN ModePort-Based VLAN

No LAN1 LAN2 LAN3 LAN4 Line Sniffing

--

1

2. -
3. -
4. -
5. -
6. -
7. -
8. -

Setup Command Menu 81

Show 16 more labels / short text on this page
----------------------------------------------------------------------------- · F Access · F Access · F Access · F Access · F Access · F Trunk · F Trunk · F Trunk · F Trunk · F Trunk · F Trunk · ----------------------------------------------------------------------------- · Virtual LAN Parameter · Virtual LAN Table · -----------------------------------------------------------------------------
Page 82 of the Patton electronic 2160 user manual — QoS
Page 82 · click to enlarge
Page 82

QoS Quality of Service (QoS) refers to both a network's ability to deliver data with minimum delay, and the net- working methods used to control the use of bandwidth. Without QoS, all traffic date is equally likely to be dropped when the network is congested. This can cause a reduction in network performance and mark the net- work inadequate for a time-critical application such as video-on-demand.

The qos command menu lists commands for managing traffic. Move the cursor “ >>” to qos in the setup menu and press Enter. The following menu displays:

>> mode Trigger Quality of Service function

qSchdl Modify queue schedule type

qweight Modify queue weight

q0GrssRt Modify queue 0 egress rate

q1GrssRt Modify queue 1 egress rate

q2GrssRt Modify queue 2 egress rate

q3GrssRt Modify queue 3 egress rate

portPri Modify port priority

vlanTagPri Modify VLAN TAG priority

ipDscpPri Modify IP DSCP priority

list Show QoS configuration

Mode You can choose from three types of QoS: Port-Based, VLAN Tag, and IP DSCP. If you are not going to use the QoS function, set this option to Disable.

Commandsetup qos mode <Disable|PortBased|VlanTag|IpDscp>

Message: Please input the following information.

Trigger qoS function (TAB Select) :

Table 21 shows the options available within the QoS mode command menu:

Table 21. VLAN Mode Options

QoS Mode F Disable F Port-Based F VLAN Tag F IP DSCP

Queue Schedule There are two types of queue schedule. Select from Type 1, Type 2 or Type 3. Table 22 explains the schedule types:

Table 22. Queue Schedule Types

Queue 0 1 2 3

Type 1 WRR

Type 2 BE WFQ WFQ WFQ

Type 3 BE WFQ WFQ SP

Setup Command Menu 82

· Menu Options

Page 83 of the Patton electronic 2160 user manual — Queue Weight
Page 83 · click to enlarge
Page 83
Commandsetup qos qSchdl <Type1|Type2|Type3>

Message: Please input the following information.

Operation type (TAB Select) <Type1>Type1

The Queue types are Weight Round Robin (WRR), Weighted Fair Queuing (WFQ), Best Effort (BE), and Strictly Priority (SP).

  • Weight Round Robin (WRR): All received packets will be stored into Queue 1, Queue 2, Queue 3, and Queue 4. Assign a weight value for each queue. Then, WRR will re-assemble all packets from the four queues based on the weight assignments.
  • Weighted Fair Queuing (WFQ): WFQ is a generalization of processor sharing, which allows several sessions to share the same link.
  • Best Effort (BE): The BE Queue Type is used for data applications that have low priority or the potential to delay. BE does not use traffic priority or weight assignments, therefore BE is not recommended for high priority data, such as video or voice.
  • Strictly Priority (SP): The SP Queue Type uses queues that are based on priority only. SP transmits the highest priority queue first, then the next highest priority queue, and so on. However, if there is always some content in the highest priority queue, then the other packets in the rest of queues will not be sent until the highest priority queue is empty. The SP algorithm is preferred when the received packets contain some high priority data, such as voice and video.

Table 23. Queue Schedule Options

Queue Schedule F Type 1 F Type 2 F Type 3

Queue Weight This setting configures the weight value for each queue.

Commandsetup qos qweight <0~3> <1~15>

Message: Please input the following information.

Queue index <0~3>0

Weight value (ENTER for default) : 1

For example, the default values are shown below:

[ setup qos qweight 0 1]

[ setup qos qweight 1 2]

[ setup qos qweight 2 4]

[ setup qos qweight 3 8]

QoS Mode 0 1 2 3 Weight Value

Setup Command Menu 83

· Menu Options ·

Page 84 of the Patton electronic 2160 user manual — LAN 1
Page 84 · click to enlarge
Page 84

Queue Egress Rate Queues 0-3 can set up the egress rate for WFQ configuration.

q0GrssRt Modify queue 0 egress rate

q1GrssRt Modify queue 1 egress rate

q2GrssRt Modify queue 2 egress rate

q3GrssRt Modify queue 3 egress rate

The egress rate N value can be set from 0 to 22. The N value 0 means no limits.

The egress data rate is a multiple of 1024kbps.

For example, the egress data rate = N value (1 to 22) x 1024 Kbps.

Table 24. Egress Rate (N Value)

0 1 2 3

LAN 1

LAN 2

LAN 3

LAN 4

DSL

Commandsetup qos portPri <1~6> <0~3>

Message: Please input the following information.

Port index <1~6>1

Queue index (ENTER for default) : 3

Set up the queue value (0, 1, 2 or 3) on each port.

Table 25. Port-Based Priority QoS Options

Port 1 (LAN1) 2 (LAN2) 3 (LAN3) 4 (LAN4) 5 (Line) 6 (Sniffing)

VLAN Tag Priority QoS

Commandsetup qos vlanTagPri <0~7> <0~3>

Message: Please input the following information.

VLAN TAG index <0~7>0

Queue index (ENTER for default) : 1

Set up the queue index (0, 1, 2 or 3) on Priority VLAN Tag.

Setup Command Menu 84

Show 6 more labels / short text on this page
Egress Queue · Port · Port-Based Priority QoS · ----------------------------------------------------------------------------- · Queue Index · ----------------------------------------------------------------------------
Page 85 of the Patton electronic 2160 user manual — IP DSCP Priority QoS
Page 85 · click to enlarge
Page 85

VLAN Tag Priority uses the tag field information which has been inserted into an Ethernet frame. If a port has an 802.1Q-compliant device attached (such as this Ethernet Extender), these tagged frames can carry VLAN membership information.

Priority defines the user priority level for different classes of traffic. There are 8 possible priority levels, with 0 being the lowest priority level and 7 being the highest level. Each Priority level can be set queue from 0 to 3.

Table 26. VLAN Tag Priority Levels

Priority Level Traffic Type

0 (default) Best Effort

5 Video, less than 100 milliseconds latency and jitter

6 Voice, less than 10 milliseconds latency and jitter

For example, you can set the Model 2160 to use Weighted Round-Robin (WRR) queuing (Type 1) that speci- fies a relative weight of each queue. WRR uses a predefined relative weight for each queue that determines the percentage of s time to services for each queue before moving on to the next queue.

Table 27. VLAN Tag Priority QoS Options

VLAN Tag Index 0 1 2 3 4 5 6 7

IP DSCP Priority QoS Differentiated Services (DiffServ) is a class of service (CoS) model that enhances best-effort Internet services by differentiating traffic by users, service requirements and other criteria. Packets are specifically marked, allowing network nodes to provide different levels of service, as appropriate for video playback, voice calls or other delay-sensitive applications, via priority queuing or bandwidth allocation.

The DSCP value used to identify 64 levels (26=64) of service determines the forwarding behavior that each packet gets across the DiffServ network. Based on the marking rule different kinds of traffic can be marked for different priorities of forwarding. Resources can then be allocated according to the DSCP values and the con- figured policies.

Set up queue index (0, 1, 2 or 3) on each DSCP:

Commandsetup qos ipDscpPri <0~63> <0~3>

Message: Please input the following information.

IP DSCP index <0~63>0

Queue index (ENTER for default) :

Setup Command Menu 85

Show 8 more labels / short text on this page
1 Background · 2 Spare · 3 Excellent Effort · 4 Controlled Load · 7 Network Control · Queue Index · ----------------------------------------------------------------------------- · -----------------------------------------------------------------------------
Page 86 of the Patton electronic 2160 user manual — List
Page 86 · click to enlarge
Page 86

Table 28. IP DSCP Priority QoS Options

Patton electronic 2160 — List diagram (page 86)
Fig. 68 · List

DSCP Queue Index DSCP Queue Index DSCP Queue Index DSCP Queue Index 0 16 32 48 1 17 33 49 2 18 34 50 3 19 35 51 4 20 36 52 5 21 37 53 6 22 38 54 7 23 39 55 8 24 40 56 9 25 41 57 10 26 42 58 11 27 43 59 12 28 44 60 13 29 45 61 14 30 46 62 15 31 47 63

List Use the list command to view the QoS settings.

Rate The rate command menu lists commands for setting the port rate. Move the cursor “ >>” to rate in the setup menu and press Enter. The following menu displays:

>> port Modify port rate

list Show Rate Control configuration

Select the port you want to modify, then set up the data rate.

Commandsetup rate port <1~5> <0~22>

Message: Please input the following information.

Port index <1~5>1

rate (ENTER for default) :

The data rate is a multiple of 1024kbps with the setup rate. Table 29 shows the options available to set up the data rate:

Table 29. Rate Options

Patton electronic 2160 — List diagram (page 86)
Fig. 69 · List

Port 1 LAN1 F No Limit F 128K F 256K F 512K F 1M F

Port 2 LAN2 F No Limit F 128K F 256K F 512K F 1M F

Port 3 LAN3 F No Limit F 128K F 256K F 512K F 1M F

Port 4 LAN4 F No Limit F 128K F 256K F 512K F 1M F

Port 5 Line F No Limit F 128K F 256K F 512K F 1M F

Port 6 Sniffing F No Limit F 128K F 256K F 512K F 1M F

Setup Command Menu 86

Page 87 of the Patton electronic 2160 user manual — Management
Page 87 · click to enlarge
Page 87

Management The Management command menu lists commands for configuring the IP address and subnet mask for the Management port. Move the cursor “ >>” to Management in the setup menu and press Enter. The following menu displays:

>> address Management IP address and subnet mask

Commandsetup Management <1~1> <more...>

Message: Please input the following information.

Interface number :

The Model 2160 only has one Management interface. The default interface number is 1. The default IP address and subnet mask are 196.168.1.1 and 255.255.255.0 .

Commandsetup Management 1 address <ip> <netmask>

Message: Please input the following information.

IP address (ENTER for default) :

Subnet mask (ENTER for default) :

DHCP Dynamic Host Configuration Protocol (DHCP) is a communication protocol that allows network adminis- trators to manage and automate the assignment of Internet Protocol (IP) addresses in an organization's net- work. Each machine that can connect to the Internet needs a unique IP address. When an organization sets up the users with a connection to the Internet, an IP address must be assigned to each machine.

Without DHCP, the IP address must be entered manually at each computer. If computers move to another location in another part of the network, a new IP address must be entered. DHCP lets a network administrator supervise and distribute IP addresses from a central point and automatically sends a new IP address when a computer is plugged into a different place in the network.

Setup Command Menu 87

· ·

Page 88 of the Patton electronic 2160 user manual — DHCP Server
Page 88 · click to enlarge
Page 88

DHCP Server The dhcp command menu lists commands for configuring DHCP settings. Move the cursor “ >>” to dhcp in the setup menu and press Enter. The following menu displays:

>> generic DHCP server generic parameters

fixed DHCP server fixed host IP list

list Show DHCP configuration

The generic command menu lists commands for configuring general DHCP settings. Move the cursor “ >>” to generic in the dhcp menu and press Enter. The following menu displays:

>> active Trigger DHCP server function

gateway Default gateway for DHCP client

netmask Subnet mask for DHCP client

ip_range Dynamic assigned IP address range

lease_time Configure max lease time

name_server1 Domain name server1

name_server2 Domain name server2

name_server3 Domain name server3

Table 30. DHCP Command Descriptions

Active Trigger DHCP server function

Gateway Configure default gateway for DHCP client

Netmask Configure subnet mask for DHCP client

IP Range Configure dynamic assigned IP address range

Lease Time Set up dynamic IP maximum lease time

Name Server 1 Set up the IP address of name server #1

Name Server 2 Set up the IP address of name server #2

Name Server 3 Set up the IP address of name server #3

DHCP Fixed Host The dhcp command menu lists commands for configuring DHCP settings. Move the cursor “ >>” to dhcp in the setup menu and press Enter. The following menu displays:

generic DHCP server generic parameters

>> fixed DHCP server fixed host IP list

relay DHCP relay parameter

list Show DHCP configuration

The fixed command menu lists commands for configuring a Fixed Host IP Address list. Move the cursor “ >>” to fixed in the dhcp menu and press Enter. The following menu displays:

>> add Add a fixed host entry

delete Delete a fixed host entry

Setup Command Menu 88

Command Description

Page 89 of the Patton electronic 2160 user manual — DNS Proxy
Page 89 · click to enlarge
Page 89

When using the fixed host entry function, you must enter the MAC address and IP address at the same time. You can configure up to 10 maximum fixed host IP addresses.

Use the list command to view the DHCP configuration.

DNS Proxy The dns_proxy command allows you to set up three DNS servers for the Model 2160. Move the cursor “ >>” to dns_proxy in the setup menu and press Enter.

Commandsetup dns_proxy <IP> [IP] [IP]

Message: Please input the following information.

DNS server 1 (ENTER for default) : 10.0.10.1

DNS server 210.10.10.1

DNS server 3:

Host Name A Host Name is a unique name that attaches a host to a network. The hostname is used to identify a particular host in various forms of electronic communication. Some ISP providers require the Host Name as identifica- tion. You may check with your ISP to see if your Internet service has been configured with a host name. In most cases, you can ignore this field.

Move the cursor “ >>” to hostname in the setup menu and press Enter. The host name cannot use spaces and cannot have more than 15 characters.

Commandsetup hostname <name>

Message: Please input the following information.

Local hostname (ENTER for default) : test

Factory Default If you want to restore factory default settings for the Model 2160, move the cursor “ >>” to default in the setup menu and press Enter.

Commandsetup default <name>

Message: Please input the following information.

Are you sure? (Y/N)y

Setup Command Menu 89

Show 6 more labels / short text on this page
---------------------------------------------------------------------- · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · ----------------------------------------------------------------------
Page 90 of the Patton electronic 2160 user manual — Status Command Menu
Page 90 · click to enlarge
Page 90

Status Command Menu

The status command menu lists commands for viewing the system status of interfaces on the Model 2160. Move the cursor “ >>” to status in the main menu and press Enter.

When you enter the status command, the following menu displays:

>> LINE Show LINE status

interface Show interface statistics status

Table 31. Status Command Menu

LINE The LINE status includes mode, line rate, SNR margin, attenuation, and CRC error count of the local side modem, and SNR margin, attenuation and CRC error count of remote side modem. The modem can access remote side information via EOC (embedded operation channel).

interface Use the interface command to view the statistic status of the Management interface.

LINE Status The LINE command shows the status of the Line port. Move the cursor “ >>” to LINE in the status menu and press Enter. The LINE status includes mode, line rate, SNR margin, attenuation, and CRC error count of the local side Ethernet Extender, and SNR margin, attenuation and CRC error count of the remote side Ethernet Extender.

Patton electronic 2160 — Status Command Menu diagram (page 90)
Fig. 70 · Status Command Menu

Figure 64. LINE Status

Status Command Menu 90

Command Description

Page 91 of the Patton electronic 2160 user manual — Interface Status
Page 91 · click to enlarge
Page 91

Interface Status To view the status of the Management interface, move the cursor “ >>” to interface in the status menu and press Enter.

Patton electronic 2160 — Interface Status diagram (page 91)
Fig. 71 · Interface Status

Figure 65. Interface Status

Table 32. Interface Statistics

InOctets The number of received bytes on this port

InPackets The number of received packets on this port

OutOctets The number of transmitted bytes on this port

OutPackets The number of transmitted packets on this port

InDiscards The discarded number of received packets on this port

OutDiscards The discarded number of transmitted packets on this port

Status Command Menu 91

Parameter Description

Page 92 of the Patton electronic 2160 user manual — Show Command Menu
Page 92 · click to enlarge
Page 92

Show Command Menu

The show command menu lists commands for viewing system and configuration information for the Model 2160. Move the cursor “ >>” to show in the main menu and press Enter.

When you enter the show command, the following menu displays:

>> system Show general information

script Show all configuration in command script

Table 33. Show Command Menu

system Displays general system information

script Displays configuration information in command script

Move the cursor “ >>” to system in the show menu and press Enter.

Patton electronic 2160 — Show Command Menu diagram (page 92)
Fig. 72 · Show Command Menu

Figure 66. System Information

Patton electronic 2160 — Show Command Menu diagram (page 92)
Fig. 73 · Show Command Menu

Figure 67. Show Script

Show Command Menu 92

Command Description

Page 93 of the Patton electronic 2160 user manual — Ping Command
Page 93 · click to enlarge
Page 93

Write Command

The write command saves all new configuration changes to Flash on the Model 2160. You must use the write command and reboot the Ethernet Extender for new configuration changes to tak effect. Move the cursor “ >>” to write in the main menu and press Enter.

Commandwrite <CR>

Message: Please input the following information.

Are you sure? (y/n)y

Reboot Command

The reboot command restarts the Model 2160. Move the cursor “ >>” to reboot in the main menu and press Enter.

Commandreboot <CR>

Message: Please input the following information.

Do you want to reboot? (y/n): y

Type “y” to begin the reboot process.

Ping Command

The ping command checks the connection of the Model 2160 to the network. Move the cursor “ >>” to ping in the main menu and press Enter.

The ping command sends an echo request packet to an address, and then waits for reply. The ping output can help you evaluate path-to-host reliability, delays over the path, and whether the host can be reached or is func- tioning correctly.

Commandping <ip> [1~65534|-t] [1~1999]

Message: Please input the following information.

IP address <IP>10.0.0.1

Number of ping request packets to send (TAB select): -t

Data size [1~1999]32

There are 3 parameters for the ping command:

  • IP address: Enter the IP address that you want to ping.
  • Number of ping request packed to send: Use the TAB key to select the following options.
- DefaultSends 4 packets only
Show 5 more labels / short text on this page
---------------------------------------------------------------------- · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · Write Command 93
Page 94 of the Patton electronic 2160 user manual — Write Command
Page 94 · click to enlarge
Page 94
- 1~65534Sets the number of ping request packets from 1 to 65534
- -tResults run continuously until you press the Ctrl key to stop the process
  • Data Size: Select from 1 to 1999

Ping Command 94

Page 95 of the Patton electronic 2160 user manual — Administration Command Menu
Page 95 · click to enlarge
Page 95

Administration Command Menu

The admin command menu lists commands for modifying user profiles, Telnet access, Simple Network Man- agement Protocol (SNMP), and supervisor information (username and password). Move the cursor “ >>” to admin in the main menu and press Enter.

When you enter the admin command, the following menu displays:

>> user Manage user profile

security Setup system security

snmp Configure SNMP parameter

passwd Change supervisor password

id Change supervisor ID

User Profile The user command menu lists commands to clear, modify, and list user profiles. You can create up to 5 user profiles to access the Model 2160 vis the console port. However, users with supervisor privleges have access to changing the configuration of the Model 2160.

Move the cursor “ >>” to user in the admin menu and press Enter. The following menu displays:

>> clear Clear the user profile

modify Modify the user profile

list List the user profile

Use the clear command to delete a user. Use the list command to show information for a user profile. Use the modify command to edit user information or add a new user to a user profile.

Modify/Add User To modify a user profile or add a new user, move the cursor “ >>” to modify in the user menu and press Enter. Select the profile number for the user profile you want to modify.

Commandadmin user modify <1~5> <more...>

Message: Please input the following information.

Legal access user profile number : 2

The modify menu displays:

>> attrib UI mode

profile User name and password

Move the cursor “ >>” to attrib in the modify menu and press Enter.

Commandadmin user modify 2 attrib <Command|Menu>

Message: Please input the following information.

User interface (TAB Select) :

Administration Command Menu 95

· ·

Page 96 of the Patton electronic 2160 user manual — Security
Page 96 · click to enlarge
Page 96

There are two UI modes for setting up the Model 2160, command and menu mode. The menu mode uses a menu-driven interface. The command mode uses line commands. (Command mode is not covered in this manual).

Move the cursor “ >>” to profile in the modify menu and press Enter.

Commandadmin user modify 2 profile <name> <pass_conf>

Message: Please input the following information.

Legal user name (ENTER for default) :

Input the old Access password****
Input the new Access password****
Re-type Access password*****

Enter the user name and set up the new access password. You must enter the new assess password twice for confirmation.

Use the list command to view information for each user profile, including user name and UI mode.

Security The security command menu lists commands to configure sixteen legal IP addresses for Telnet access and the Telnet port number. Move the cursor “ >>” to security in the admin menu and press Enter. The following menu displays:

>> port Configure telnet TCP port

ip_pool Legal IP address pool

list Show security profile

Telnet TCP Port To set up the Telnet TCP port, move the cursor “ >>” to port in the security menu and press Enter. You can select a port number from 1 to 65534. The default number is 23.

Commandadmin security port <1~65534>

Message: Please input the following information.

Telnet Listening TCP Port (ENTER for default) :

Legal IP Address Pool The default legal address is 0.0.0.0. (on entry number 1). This means that there are no IP address restrictions for accessing the MOdel 2160 via Telnet. To change the legal IP address pool, move the cursor “ >>” to ip_pool in the security menu and press Enter. Select modify to set up the IP address pool.

Administration Command Menu 96

· ·

Page 97 of the Patton electronic 2160 user manual — SNMP
Page 97 · click to enlarge
Page 97
Commandadmin security ip_pool modify <1~16> <ip>

Message: Please input the following information.

Client address pool entry number : 1

Client IP address (ENTER for default) :

You can configure up to sixteen entries for legal address pools. Use the clear command to remove a legal client IP address from any pool entry number. Use the list command to view information for all of the security pro- files, including the Telnet TCP port and the legal IP addresses.

SNMP Simple Network Management Protocol (SNMP) provides the exchange of messages between a network man- agement client and a network management agent for remote management of network nodes. These messages contain requests to get and set variables that exist in network nodes in order to obtain statistics, set configura- tion parameters, and monitor network events. SNMP communications can occur over the LAN or WAN con- nection.

The Model 2160 can generate SNMP traps to indicate alarm conditions, and it relies on SNMP community strings to implement SNMP security. This Model 2160 support both MIB I and MIB II.

The snmp command menu lists commands for configuring SNMP communities and traps. Move the cursor “ >>” to snmp in the admin menu and press Enter. The following menu displays:

>> community Configure community parameter

trap Configure trap host parameter

Community To set up SNMP communities, move the cursor “ >>” to community in the snmp menu and press Enter. You can configure five community entries.

Commandadmin snmp community <1~5> <more...>

Message: Please input the following information.

Community entry number <1~5>2

The following menu displays:

>> edit Edit community entry

list Show community configuration

Select edit and press Enter.

Administration Command Menu 97

·

Page 98 of the Patton electronic 2160 user manual — Trap host
Page 98 · click to enlarge
Page 98
Command... 2 edit <Disable|Enable> <string> <Read_Only|Read_Write|Denied>

Message: Please input the following information.

Validate (TAB Select) <Enable>Enable

Community (ENTER for default) :

Access right (TAB Select) :

You can set up the following options:

  • Validate: Set to Enable or Disable .
  • Community: Enter the desired password for community access.
  • Access right: Set to Read only , Read Write or Denied .

Read_Only Users have read-only access to the community

Read_Write Users have read and write access to the community

Denied There is no access to the community

Use the list command to view all SNMP community pool entries. You can also confgiure five SNMP trap entries.

Trap host To set up SNMP traps, move the cursor “ >>” to trap in the snmp menu and press Enter. You can configure five trap entries.

Commandadmin snmp trap <1~5> <more...>

Message: Please input the following information.

Trap host entry number <1~5>2

The following menu displays:

>> edit Edit trap host parameter

list Show trap configuration

Select edit and press Enter.

Commandadmin snmp trap 1 edit <Disable|1|2> <ip> <string>

Message: Please input the following information.

Version (TAB Select) :

Trap host IP address (ENTER for default) :

Community (ENTER for default) :

Administration Command Menu 98

Show 4 more labels / short text on this page
----------------------------------------------------------------------------- · ---------------------------------------------------------------------- · ----------------------------------------------------------------------------- · -----------------------------------------------------------------------------
Page 99 of the Patton electronic 2160 user manual — Telnet/Console •
Page 99 · click to enlarge
Page 99

You can set up the following options:

  • Version: Set to Disable , Version 1 or Version 2 .
  • Trap host IP address: Enter the dtrap host IP address.
  • Community: Enter the community password.

Use the list command to view all SNMP trap host entries.

Supervisor Password and ID The supervisor ID and password is the last option in the security command menu, but it is the most important menu item. Users who access the Model 2160 via a web browser or console/Telnet must use the supervisor ID and password to configure the Model 2160. You should change the supervisor ID and password after initial configuration.

  • Web Browser

Telnet/Console •

Supervisor Password To change the supervisor password, move the cursor “ >>” to passwd in the security menu and press Enter. The default password is root.

Commandadmin passwd <pass_conf>

Message: Please input the following information.

Input old Supervisor password****
Input new Supervisor password********
Re-type Supervisor password********

Supervisor ID To change the supervisor ID, move the cursor “ >>” to id in the security menu and press Enter. The default ID is root.

Commandadmin id <name>

Message: Please input the following information.

Legal user name (ENTER for default) :

Figure 47 on page 62 shows a flowchart of user access functions using the web browser or console/Telnet.

Administration Command Menu 99

Show 4 more labels / short text on this page
ID Password · ---------------------------------------------------------------------- · ---------------------------------------------------------------------- · -----------------------------------------------------------------------------
Page 100 of the Patton electronic 2160 user manual — Utility Command Menu
Page 100 · click to enlarge
Page 100

Utility Command Menu

Model 2160 has three utility tools embedded in the firmware: upgrade, backup and restore. You can update the new firmware via TFTP upgrade tools, backup the configuration via the TFTP backup tool and restore the configuration via the TFTP restore tool. To upgrade the firmware, you must have the new firmware file named *.bin that will be supported by supplier. Also, you must have your own TFTP server. For backup and restore operations, you must also have your own TFTP server to backup and restore the configuration files.

Move the cursor “ >>” to utility in the main menu and press Enter. The following menu displays:

>> upgrade Upgrade main software

backup Backup system configuration

restore Restore system configuration

Upgrade main software To upgrade the Model 2160 firmware, move the cursor “ >>” to upgrade in the utility menu and press Enter. Type the TFTP server IP address and name of the upgraded firmware file.

Commandutility upgrade <ip> <file>

Message: Please input the following information.

TFTP server IP address (ENTER for default) :

Upgrade filename (ENTER for default) :

Backup system configuration To backup the current system configuration, move the cursor “ >>” to backup in the utility menu and press Enter. Type the TFTP server IP address and name for the backup file.

Commandutility backup <ip> <file>

Message: Please input the following information.

TFTP server IP address (ENTER for default) :

Upgrade filename (ENTER for default) :

Restore system configuration To restore a saved configuration file, move the cursor “ >>” to restore in the utility menu and press Enter. Type the TFTP server IP address and name of the system configuration file you want to restore to the Model 2160.

Commandutility restore <ip> <file>

Message: Please input the following information.

TFTP server IP address (ENTER for default) :

Upgrade filename (ENTER for default) :

Utility Command Menu 100

Show 5 more labels / short text on this page
----------------------------------------------------------------------------- · ----------------------------------------------------------------------------- · ----------------------------------------------------------------------------- · ----------------------------------------------------------------------------- · -----------------------------------------------------------------------------
Page 101 of the Patton electronic 2160 user manual — Utility Command Menu
Page 101 · click to enlarge
Page 101

Utility Command Menu 101

Page 102 of the Patton electronic 2160 user manual — Exit Command
Page 102 · click to enlarge
Page 102

Exit Command

To log out of the system without saving your changes, move the cursor “ >>” to exit in the main menu and press Enter.

enable Modify command privilege

status Show running system status

show View system configuration

write Update flash configuration

reboot Reset and boot system

ping Packet internet groper command

admin Setup management features

utility TFTP upgrade utility

>> exit Quit system

Commandexit <CR>

Message: Please input the following information.

Do you want to disconnect? (y/n): y

Press “y” to exit the system. A confirmation screen displays:

Connection closed...

Press SPACE key to enter console mode configuration!

Show 6 more labels / short text on this page
setup Configure system · ------------------------------------------------------------------------- · ------------------------------------------------------------------------- · ------------------------------------------------------------------ · ------------------------------------------------------------------ · Exit Command 102
Page 103 of the Patton electronic 2160 user manual — Table of contents
Page 103 · click to enlarge
Page 103

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 104 of the Patton electronic 2160 user manual — Warranty Service and Returned Merchandise Authorizations (RMAs)
Page 104 · click to enlarge
Page 104

Model 2160 Series User Manual 6 • Contacting Patton for assistance

Introduction

This chapter contains the following information:

  • “Contact information” —describes how to contact Patton technical support for assistance.
  • “Warranty Service and Returned Merchandise Authorizations (RMAs)” —contains information about the Model 2160 warranty and obtaining a return merchandise authorization (RMA).

Contact information

Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems:

Patton support headquarters in the USA

  • Online support—available at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a>
  • E-mail support—e-mail sent to support@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a> will be answered within 1 business day
  • Telephone support—standard telephone support is available five days a week—from 8:00 am to 5:00 pm EST ( 1300 to 2200 UTC )—by calling +1 (301) 975-1007

Alternate Patton support for Europe, Middle East, and Africa (EMEA)

  • Online support: available at <a href="http://www.patton-inalp.com" rel="nofollow noopener" target="_blank">www.patton-inalp.com</a>
  • E-mail support: e-mail sent to support@<a href="http://patton-inalp.com" rel="nofollow noopener" target="_blank">patton-inalp.com</a> will be answered within 1 business day
  • Telephone support: standard telephone support is available five days a week-from 8:00 am to 5:00 pm CET ( 0900 to 1800 UTC/GMT ) by calling +41 (0)31 985 25 55
  • Fax: +41 (0)31 985 25 26

Warranty Service and Returned Merchandise Authorizations (RMAs)

Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.

Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.

Introduction 104

Page 105 of the Patton electronic 2160 user manual — Out-of-warranty service
Page 105 · click to enlarge
Page 105

Model 2160 Series User Manual 6 • Contacting Patton for assistance

Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.

Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.

Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.

  • 30 to 60 days: We will add a 20% restocking charge (crediting your account with 80% of the purchase price).
  • Over 60 days: Products will be accepted for repairs only.

RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:

  • Completing a request on the RMA Request page in the Support section at <a href="http://www.patton.com" rel="nofollow noopener" target="_blank">www.patton.com</a>
  • By calling +1 (301) 975-1007 and speaking to a Technical Support Engineer
  • By sending an e-mail to returns@<a href="http://patton.com" rel="nofollow noopener" target="_blank">patton.com</a>

All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.

Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:

Patton Electronics Company RMA#xxxx 7622 Rickenbacker Dr. Gaithersburg, MD 20879-4773 USA

Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.

Warranty Service and Returned Merchandise Authorizations (RMAs) 105

Page 106 of the Patton electronic 2160 user manual — Table of contents
Page 106 · click to enlarge
Page 106

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 107 of the Patton electronic 2160 user manual — Authorized European Representative
Page 107 · click to enlarge
Page 107

Model 2160 Series User Manual A • Compliance information

Compliance

EMC compliance• FCC Part 15, Class A
  • EN55022, Class A
  • EN55024

Radio and TV interference (FCC Part 15)

This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reason- able protection from such interference in a commercial installation. However, there is no guarantee that inter- ference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equip- ment and receiver are on different branches).

CE Declaration of Conformity

We certify that the apparatus described above conforms to the requirements of Council Directive 2004/108/EC on the approximation of the laws of the member states relating to electromagnetic compatibility; and Council Directive 2006/95/EC on the approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits.

The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.

Authorized European Representative

D R M Green European Compliance Services Limited. Oakdene House, Oak Road, Watchfield, Swindon, Wilts SN6 8TD, UK

Compliance 107

Page 108 of the Patton electronic 2160 user manual — Table of contents
Page 108 · click to enlarge
Page 108

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 109 of the Patton electronic 2160 user manual — Management Connector
Page 109 · click to enlarge
Page 109

Model 2160 Series User Manual B • Specifications

Line Connector

Line Modulation

TC-PAM 32

TC-PAM 16

Ethernet Connector

4 x 8-position shielded RJ-45

Auto-sensing 10/100Base-TX with half or full-duplex operation

LAN Protocols

802.1d Transparent Bridging

2K MAC address learning bridge

VLAN Support

IEEE 802.1q VLAN Tagging

Port Based VLAN, up to 4K VLANs

QoS Support

Traffic classification based on port/802.1p/DSCP (Differentiated Services Code Point )

WRR (Weighted Round Robin)/SPQ (Strict Priority Queing) scheduling algorithm

Management Connector

WEBShielded RJ-45
ConsoleShielded RJ-45
Show 4 more labels / short text on this page
Shielded RJ-45 · VLAN Stacking (Q-in-Q) · Rate limiting rule-based/port-based · Line Connector 109
Page 110 of the Patton electronic 2160 user manual — Weight
Page 110 · click to enlarge
Page 110

Model 2160 Series User Manual B • Specifications

Management Interface

CLI for local and console access; password protected;

SNMP v1/v2 (RFC 1157/1901/1905) agent and MIB (RFC 1213/1493)

EFM OAM (IEEE 802.3af)

Software upgradeable via web-browser/TFTP

Front Panel Indicators

Power, Alarm, Diagnostic, WAN Link (x4), Ethernet Link (x4), Ethernet 100M (x4)

Power Supply

ACUniversal Input (UI)—90–240 VAC (50~60Hz)

Environment

Operating Temperature0–50°C
Storage Temperature-4085° C

Dimensions

7.67L x 1.89W x 6.61D in. (195L x 48H x 168D mm)

Weight

2.86 lbs (1300 g) without power supply

Web based GUI · Management Interface 110

Page 111 of the Patton electronic 2160 user manual — Table of contents
Page 111 · click to enlarge
Page 111

Table of contents

Summary Table of Contentsp.3Table of Contentsp.4List of Figuresp.9List of Tablesp.11About this guidep.12Audiencep.12Structurep.12Precautionsp.13Safety when working with electricityp.14Preventing Electrostatic Discharge Damagep.15General observationsp.15Typographical conventions used in this documentp.16General conventionsp.16Chapter 1 General informationp.17Model 2160 overviewp.18Model 2160 front panelp.19LED descriptionsp.19Model 2160 rear panelp.20Port descriptionsp.20Reset buttonp.21Ground terminalp.21Chapter 2 Applications overviewp.22Introductionp.23Typical applicationp.23Distance chartsp.24Distance Chart 2160 Series - Auto Mode (TCPAM-32/16)p.24Distance Chart 2160 Series - Optimal Mode (TCPAM-128)p.25Distance Chart 2160 Series - TCPAM-128p.26Chapter 3 Hardware installationp.27Introductionp.28Planning the installationp.28Network diagramp.29IP related informationp.29AC Power Mainsp.29Location and mounting requirementsp.30Installing the Model 2160p.30Unpacking the Model 2160p.30Connecting cablesp.30Grounding the Model 2160 and connecting powerp.31Configuring the Model 2160p.32Web configuration requirementsp.32Console configuration requirementsp.32Telnet configuration requirementsp.32Chapter 4 Web configurationp.33Introductionp.35Setting Up the WMIp.35TCP/IP setupp.35System Loginp.35Basic Configuration Optionsp.36Operation mode and Management portp.37DHCP serverp.37LANp.39Review and save basic setup changesp.40Advanced Configuration Optionsp.41LINEp.41Line Typep.41Annex Typep.41TCPAM Typep.42Main Ratep.42SNR Marginp.42Line Probep.42VLANp.43802.1Q Tag-Based VLANp.45Port-Based VLANp.48Quality of Service (QoS)p.49Port Based Priorityp.50VLAN Tag Priorityp.53IP DSCP Priorityp.56Rate Limitp.59Flow Controlp.59Status Optionsp.60LINE Statusp.60Management Statusp.60LAN Statusp.61Performance Statusp.61Administration Optionsp.62Security Administrationp.62User Profilesp.62Remote Management Hostsp.63SNMP Administrationp.63Community Poolp.64Trap Host Poolp.65Remote Syslogp.65Utility Optionsp.66System Informationp.66Configuration Toolp.66Upgradep.67Logoutp.68Restartp.68Chapter 5 Console and Telnet configurationp.69Introductionp.71Log in to the console interfacep.71Log in using Telnetp.71Interface commandsp.71Window structurep.72Main Menu Treep.73Menu tree for authorized usersp.73Menu tree for unauthorized usersp.74Enable Command Menup.75Setup Command Menup.76Linep.76Modep.77Linkp.77Annex Typep.77TCPAM Typep.77Maximum Main Ratep.77SNR Marginp.77Line Probep.78Clearp.78LANp.78VLANp.79Modep.79QoSp.82Modep.82Queue Schedulep.82Queue Weightp.83Queue Egress Ratep.84Port-Based Priority QoSp.84VLAN Tag Priority QoSp.84IP DSCP Priority QoSp.85Listp.86Ratep.86Managementp.87DHCPp.87DHCP Serverp.88DHCP Fixed Hostp.88DNS Proxyp.89Host Namep.89Factory Defaultp.89Status Command Menup.90LINE Statusp.90Interface Statusp.91Show Command Menup.92Write Commandp.93Reboot Commandp.93Ping Commandp.93Administration Command Menup.95User Profilep.95Modify/Add Userp.95Securityp.96Telnet TCP Portp.96Legal IP Address Poolp.96SNMPp.97Communityp.97Trap hostp.98Supervisor Password and IDp.99Supervisor Passwordp.99Supervisor IDp.99Utility Command Menup.100Upgrade main softwarep.100Backup system configurationp.100Restore system configurationp.100Exit Commandp.102Chapter 6 Contacting Patton for assistancep.103Introductionp.104Contact informationp.104Warranty Service and Returned Merchandise Authorizations (RMAs)p.104Warranty coveragep.104Out-of-warranty servicep.105Returns for creditp.105Return for credit policyp.105RMA numbersp.105Shipping instructionsp.105Appendix A Compliance informationp.106Compliancep.107EMC compliance:p.107Radio and TV interference (FCC Part 15)p.107CE Declaration of Conformityp.107Authorized European Representativep.107Appendix B Specificationsp.108Line Connectorp.109Line Modulationp.109Ethernet Connectorp.109LAN Protocolsp.109VLAN Supportp.109QoS Supportp.109Management Connectorp.109Management Interfacep.110Front Panel Indicatorsp.110Power Supplyp.110Environmentp.110Dimensionsp.110Weightp.110Appendix C Port pin-outsp.111Introductionp.112Console portp.112Ethernetp.113Line (CopperLink)p.113
Page 112 of the Patton electronic 2160 user manual — Console port
Page 112 · click to enlarge
Page 112

Model 2160 Series User Manual C • Port pin-outs

Introduction

This section provides pin-out information for the ports of the Model 2160.

Console port

Configuration settings9600 bps, 8 bits, no parity, 1 stop bit, no flow control

8–RTS (N/C) 7–CTS (N/C) 6–TD 5–RD 4–SG 3–DTR 2–CD (N/C) 1–DSR

1 2 3 4 5 6 7 8

Pins 1 & 3 are connected together

Figure 68. EIA-561 (RJ-45 8-pin) port

Introduction 112

Page 113 of the Patton electronic 2160 user manual — 4 TRD0+
Page 113 · click to enlarge
Page 113

Model 2160 Series User Manual C • Port pin-outs

Ethernet

Table 34. RJ45 socket 10/100Base-T

1 TX+

2 TX-

3 RX+

6 RX-

Line (CopperLink)

Table 35. RJ45 socket CopperLink

4 TRD0+

5 TRD0-

3 TRD1+

6 TRD1-

7 TRD2+

8 TRD2-

1 TRD3+

2 TRD3-

Pin Signal · Pin Signal · Ethernet 113

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 2160

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 2160

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 2160 manual PDF

113 pages·3.3 MB·Switch·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…