MODEL 2124/2130 Ethernet MicroBridge


Part# 07M2124-UM Doc# 08306U2-001, Rev. B Revised 10/27/06 An ISO-9001 Certified Company


Patton Electronics warrants all Model 2124/2130 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specif- ically disclaims all other warranties, expressed or implied, and the instal- lation or use of this product shall be deemed an acceptance of these terms by the user.
The Model 2124/2130 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer’s instructions—may cause interference to radio and televi- sion reception. The Model 2124/2130 has been tested and complies with the limits for a Class A computing device in accordance with the specification in Subpart J of Part 15 of FCC rules, that are designed to provide reasonable protection from such interference in a commercial installation. However, this is no guarantee that interference will not occur in a particular installation. If the Model 2124/2130 does cause interfer- ence to radio or television reception, which can be determined by discon- necting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equip- ment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches). In the event the user detects intermittent or continuous product malfunction due to nearby high power transmitting radio frequency equipment, the user is strongly advised to use only a shielded twisted pair data cable that is bonded to metalized external outer shield plugs at both ends. The use of a shielded cable satisfies compliance with the Electromagnetic Compati- bility (EMC) directive.

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Cer- tificate of Compliance is available by contacting Patton Technical Sup- port.
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Mate- rials Authorization (RMA) number on the outside of the shipping con- tainer. This number may be obtained from Patton Electronics Technical Support at:
Patton Electronics’ technical staff is also available to answer any ques- tions that might arise concerning the installation or use of your Model 2124/2130. Technical Support hours: 8AM to 5PM EST, Monday through Friday.
telephone network.

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Pat- ton Electronics Technical Support at (301) 975-1007.
The Patton Model 2124/2130 MicroBridge is an Ethernet Bridge that pro- vides LAN extension when used in conjunction with a V.24 or EIA-530 DCE device, such as a DSU/CSU, NTU, or router. The Model 2124/2130 performs transparent Ethernet bridging and functions at the MAC level, thus is transparent to higher level protocols such as TCP/IP, DECnet, NETBIOS, and IPX network protocols. Only broadcast, multicast, or frames set up for peered LAN are forwarded. The Model 2124/2130 is 802.3 Ethernet compliant and supports PPP Bridging Control Protocol (RFC 1638) on the DTE side.

PPP is a protocol used for multi-plexed transport over a point-to-point link. PPP operates on all full duplex media, and is a symmetric peer-to- peer protocol, which can be broken into three main components: 1. A standard method to encapsulate datagrams over serial links; 2. A Link Control Protocol (LCP) to establish, configure, and test the data-link con- nection; 3. A family of Network Control Protocols (NCPs) to establish and configure different network layer protocols.
In order to establish communications over a point-to-point link, each end of the PPP link must first announce its capabilities and agree on the parameters of the link’s operation. This exchange is facilitated through LCP Configure-Request packets.
Once the link has been established and optional facilities have been negotiated, PPP will attempt to establish a network protocol. PPP will use Network Control Protocol (NCP) to choose and configure one or more network layer protocols. Once each of the network layer protocols have been configured, datagrams from the established network layer protocol can be sent over the link. The link will remain configured for these communications until explicit LCP or NCP packets close the link down, or until some external event occurs.
The PPP Bridging Control Protocol (BCP), defined in RFC 1638, config- ures and enables/disables the bridge protocol on both ends of the point- to-point link. BCP uses the same packet exchange mechanism as the Link Control Protocol (LCP). BCP is a Network Control Protocol of PPP, bridge packets may not be exchanged until PPP has reached the net- work layer protocol phase.
In situations where a routed network requires connectivity to a remote Ethernet network, the interface on a router can be configured as a PPP IP Half Bridge. The serial line to the remote bridge functions as a Virtual Ethernet interface, effectively extending the routers serial port connec- tion to the remote network. The bridge device sends bridge packets (BPDU's) to the router's serial interface. The router will receive the layer three address information and will forward these packets based on its IP address.
Figure 1 shows a typical Cisco router with a serial interface configured as a PPP Half Bridge. The router serial interface uses a remote device that supports PPP bridging to function as a node on the remote Ethernet network. The serial interface on the Cisco will have an IP address on the same Ethernet subnet as the bridge.


Figure 1. Cisco router with serial interface, configured as PPP Half Bridge. For example, the customer site is assigned the addresses 192.168.1.0/ 24 through 192.168.1.1/24. The address 192.168.1.1/24 is also the default gateway for the remote network. The above settings remove any routing/forwarding intelligence from the CPE. The associated Cisco con- figuration will set serial interface (s0) to accommodate half bridging for the above example.
Authentication is optional under PPP. In a point-to-point leased-line link, incoming customer facilities are usually fixed in nature, therefore authen- tication is generally not required. If the foreign device requires authenti- cation via PAP or CHAP, the PPP software will respond with default Peer-ID consisting of the units Ethernet MAC address and a password which consists of the unit’s Ethernet MAC address.
Some networking systems do not define network numbers in packets sent out over a network. If a packet does not have a specific destination network number, a router will assume that the packet is set up for the local segment and will not forward it to any other sub-network. However, in cases where two devices need to communicate over the wide-area, bridging can be used to transport non-routable protocols.
Figure 2 illustrates transparent bridging between two routers over a serial interface (s0). Bridging will occur between the two Ethernet Inter- faces on Router A (e0 and e1) and the two Ethernet Interfaces on Router B (e0 and e1).


Figure 2. Transparent bridging between two routers over a serial link.

The 2124/2130 is equipped with Network, DTE, and power interfaces. This section briefly describes connnection to each interface.
The shielded RJ-45 Ethernet port on the Model 2124/2130 is designed to connect directly to a 10BaseT network. Figure 3 shows the 10BaseT RJ- 45 port pin description. You may make connections up to 300 feet using type 4 or 5 cable.

Figure 3. Model 2124/2130 Ethernet connector pinout
Connect the 10BaseT Ethernet Port to a Hub
The Model 2124/2130 10BaseT interface is configured as DTE (Data Terminal Equipment). Use the diagram below to construct a cable to con- nect the 2124/2130 to a 10BaseT Hub.

Connect the 10BaseT Ethernet Port to a PC (DTE)
The Model 2124/2130 10BaseT interface is configured as DTE (Data Terminal Equipment). To connect the 2124/2130 to another DTE such as a 10BaseT network interface card in a PC, construct a 10BaseT cross- over cable as shown in the diagram below.


The Model 2124/2130 offers either an AC or DC power supply.
The 2124/2130 provides a strap selectable power supply.
AC Power Supply (100-240VAC)
The Model 2124/2130 uses a 5VDC, 2A universal input 100-240VAC, power supply (center pin is +5V). The universal input power supply is equipped with a male IEC-320 connector. This power supply connects to the Model 2124/2130 via a barrel jack on the rear panel. A variety of international power cords are available for the universal power supply.
The Model 2124/2130 powers up as soon as it is plugged into an AC out- let. The unit does not have a power switch.
The 2124/2130 is factory set to be used with the AC power supply.


Figure 4. Strap positions 7 and 8 on J3
Supply DC power directly to the power supply jack. DC power supplied must be +5VDC ±5%, 500mA minimum, center positive, and can be sup- plied via a barrel type plug with 2.1/5.5/10mm I.D./O.D./Shaft Length dimensions. For this powering option, set J3 to position 7 and 8 as shown in figure 4 (factory default).
The 36-60 VDC DC to DC adapter is supplied with the DC version of the Model 2124/2130. The black and red leads plug into a DC source (nom- inal 48VDC) and the barrel power connector plugs into the barrel power supply jack on the 2124/2130. See Figure 5 below. For this powering option, set J3 to position 7 and 8 as shown in figure 4 (factory default).
DC power (+5VDC) can also be supplied via pins 21 or 25 on the DB-25 connector for the Model 2124. DC power (+5VDC) can also be supplied via pins 21 or 25 on the DB-25 connector for the Model 2130.
Figure 5. Connecting DC Power to the 2124/2130 DC Power Supply.
DC Power

There are no user-serviceable parts in the power supply section of the Model 2124/2130. For more information, please contact Patton Electronics Technical support at (301) 975-1007, via our web site at http://www.patton.com or by e-mail at support@patton.com.
Power-up 2124 via DB-25 Connector on Pin 25
Place strap position 1 and 2 on J3 for DC power supply. See Figure 6 below.
Power-up 2130 via DB-25 Connector on Pin 25
Place strap position 1 and 2 on J3 for DC power supply. See Figure 6 below.

Figure 6. Strap positions 1 and 2 on J3
Power-up 2124 via DB-25 Connector on Pin 21
Place strap position 3 and 4 on J3 for DC power supply. See Figure 7 below.
Power-up 2130 via DB-25 Connector on Pin 21
Place strap position 3 and 4 on J3 for DC power supply. See Figure 7 below.


Figure 7. Strap positions 3 and 4 on J3

All configuration is done through software auto-detection for the Model 2124/2130. Once you have configured your mux or other equipment to be connected to the 2124/2130, the unit is ready for operation. Observe that the serial port of the 2124/2130 is configured as a DTE and must connect to a DCE.
The LAN port also requires no configuration to connect to a 10BaseT Ethernet.
The 2124/2130 uses two LEDs on the Ethernet connection side. A green LED indicates that link connection to the network is established. The yel- low LED displays status codes (See section 5.1.2 for status code infor- mation).
Seven, low power, LEDs located on the top of the 2124/2130 case indi- cate POWER and V.24 or EIA-530 signal activity.
The Model 2124/2130 features two LAN LEDs that monitor general oper- ation status and the 10BaseT twisted pair link integrity. Figure 8 shows the LEDs located at the rear of the Model 2124/2130. Following Figure 8 is a description of each LED function. Figure 8 shows the LEDs located on the top of the Model 2124/2130.
LAN side LEDs


Figure 8. 2124/2130 rear view
The status LED blinks yellow from one to eleven times to indicate system status. Each pulse pattern is separated by a 2 second "off " period. Greater pulse patterns have higher priority (buffer saturation has greater priority than an empty MAC table).
Valid system statuses are:
1 pulse = system status ok 2 pulses = No MAC entries in the MAC address table 3 pulses = Clear to send (CTS) or Carrier Detect (DCD) from base unit are not asserted 4 pulses = IMRC2/IA buffer is saturated 5 pulses = WAN receive frame(s) too large 6 pulses = WAN receive frame(s) not Octet aligned 7 pulses = WAN receive frame(s) aborted 8 pulses = Detected WAN receive frame(s) with bad CRC 9 pulses = Detected LAN receive frame(s) too large 10 pulses = Detected LAN receive frame(s) not Octet aligned 11 pulses = Detected LAN receive frame(s) with bad CRC
After a status code is displayed eight times and the associated condition is removed, the status code will no longer appear.
The link LED glows green to indicate link integrity on the 10BaseT twisted pair line.
Power and DCE/DTE interface LEDs
Seven LEDs indicate POWER and DTE/DCE activity on the front of the 2124/2130.
LED Descriptions


Figure 9. Front of Model 2124/2130, showing LED indicators
TXD- Trasmit data LED (green) blinks to indicate data transitions and remains OFF when no data is transmitted (idle).
RXD- Received data LED (green) blinks to indicate data transitions and remains OFF when no data is received (idle).
DTR- Control LED (yellow)- turns ON at power up to indicate to the DCE that the 2124 is active.
CTS- Indication LED (yellow) - turns ON when the 2124 is ready to receive data from the DCE.
DCD- Status LED (yellow) - Turns ON to indicate that a carrier detect signal is received from the DCE.
CLK- Clock Signal LED (yellow) - blinks to indicate that the transmit clock from the DCE is active. The CLK LED will remain OFF to indicate the absence of the transmit clock.
PWR- LED (green) turns ON as soon as power is applied to the 2124/ 2130.

SPECIFICATIONS
LAN Connection: RJ-45, 10BaseT, 802.3 Ethernet supported by Transparent LAN bridging DTE connection: DB-25 connector, V.24 (DTE orientation) Protocol: PPP (RFC 1661) with Bridging Control Pro- tocol (RFC 1638) MAC Address Table Size: 4096 entries MAC Address Aging: MAC addresses deleted after eight minutes inactivity On-board Memory: 1 MB RAM; 128 KB FLASH Frame Latency: 1 frame LEDs LAN Side: (1) yellow, general status; (1) green, link integrity LEDs DTE Side: TXD, RXD and Power, (green); DTR,CTS,DCD, and CLK (Yellow) Power supply Input: 100-240VAC, 50-60Hz, 0.4A Power Consumption: 500mA @ 5VDC Humidity: Up to 90% non-condensing Temperature: 0 -50 C Dimensions: 9.0 x 5.3 x 2.0 cm (3.5"L x 2.1"W x 0.78"H) Compliance: FCC Part 15A CE Mark per EEC Directive 89/336/EEC Low Voltage Directive

SPECIFICATIONS
LAN Connection: RJ-45, 10BaseT, 802.3 Ethernet sup- ported by Transparent LAN bridging DTE connection: DB-25 connector, EIA-530 (DTE orienta- tion) Protocol: PPP (RFC 1661) with Bridging Control Protocol (RFC 1638) MAC Address Table Size: 4096 entries MAC Address Aging: MAC addresses deleted after eight min- utes inactivity On-board Memory: 1 MB RAM; 128 KB FLASH Frame Latency: 1 frame LEDs LAN Side: (1) yellow, general status; (1) green, link integrity LEDs DTE Side: TD, RD and Power, (green); DTR DCD, CTS and CLK, (Yellow) Power supply Input: 100-240VAC, 50-60Hz, 0.4A Power Consumption: 500mA @ 5VDC Humidity: Up to 90% non-condensing Temperature: 0 -50 C Dimensions: 9.0 x 5.3 x 2.0 cm (3.5"L x 2.1"W x 0.78"H) Compliance: FCC Part 15A CE Mark per EEC Directive 89/336/EEC Low Voltage Directive 73/23/EEC

07M2121/2135C 2124/2130 User Manual 0805DCUI 100-250 VAC Universal Power Supply
Part # Description

APPENDIX D 10BASET INTERFACE PIN ASSIGNMENT (RJ-45 FEMALE CONNECTOR)
1 TD + (data output from 2124/2130) 2 TD - (data output from 2124/2130) 3 RD + (data input to 2124/2130) 4 no connection 5 no connection 6 RD - (data input to 2124/2130) 7 no connection 8 no connection
Pin # Signal

(DB-25 MALE CONNECTOR)
1 Shield GND/Frame GND 2 TD 3 RD 4 RTS 5 CTS 7 SIG GND 8 CD 15 TX CLK 17 RCV CLK 20 DTR 21 DC Power (+5VDC) 25 DC Power (+5DC)
Pin # Signal

(DB-25 MALE CONNECTOR)
1 Shield GND/Frame GND 2 TD A 3 RD A 4 RTS A 5 CTS A 7 SIG GND 8 CD A 9 RCV CLK B 10 CD B 12 TX CLK B 13 CTS B 14 TD B 15 TX CLK A 16 RD B 17 RCV CLK A 19 RTS B 20 DTR A 21 +5VDC 23 DTR B 25 +5VDC
Pin# Signal

Via 5VDC power jack (J1)