MODEL 1088/C and 1088/D mDSL Modem with V.35 or X.21 Interface

Part# 07M1088-UM Doc# 03312U2-001 Rev. E Revised 10/23/06
An ISO-9001Certified · Company



Patton Electronics warrants all Model 1088 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifi- cally disclaims all other warranties, expressed or implied, and the instal- lation or use of this product shall be deemed an acceptance of these terms by the user.
The Model 1088 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manu- facturer's instructions—may cause interference to radio and television reception. The Model 1088 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifica- tions in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installa- tion. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1088 does cause interference to radio or television reception, which can be determined by disconnecting the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the European Union (EU). A Cer- tificate of Compliance is available by contacting Technical Support.

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materi- als Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Pat- ton Electronics Technical Support at (301) 975-1007.
The Patton Electronics mDSL Rocket provides high speed 2-wire connectiv- ity to ISPs, PTTs, and corporations using mDSL (Multi-rate Symmetric Digital Subscriber Line) technology. Multi-rate DSL offers the ability to deliver the maximum bit rate that a twisted pair line can accommodate. Supporting mul- tiple line rates from 144 kbps to 2.320 Mbps, the NetLink provides “mega- byte” speeds to leased line, LAN to LAN interconnection, and WAN access networks over 3.6 miles/5.8 km (1.054 Mbps on 24AWG/.5 mm wire).
Model 1088/C provides a V.35 interface on an M/34 female connector. Model 1088/D provides an X.21 interface on a DB-15 female connector. Features include loopback diagnostics, SNMP/HTTP remote management capabilities using NetLink Plug-and-Play and inband externally accessible configuration switches. All versions of the Rocket are compatible with Patton’s popular Model 1095 standalone and 1095RC rack card.
As a symmetric DSL NTU, NetLinkTM mDSL offers the same data rates in both directions over a single pair of regular telephone lines using Carrierless Amplitude and Phase (CAP) modulation. Line connection is made by an RJ- 45 jack. Standard versions of Model 1088 are powered by a 100/230 VAC (Universal) supply. The DC power supply option supports any DC input between 36–72 VDC.

The Model 1088 is equipped with two sets of eight DIP switches, which allow configuration of the unit for a wide variety of applications. This section describes switch locations and explains all possible configurations.
The 16 external switches are grouped into two eight-switch sets, and are externally accessible from the underside of the Model 1088 (See Figure 1).
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
S3
Figure 1. Underside of Model 1088, Showing Location of DIP Switches
The two sets of DIP switches on the underside of the Model 1088 will be referred to as S2 and S3. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions.

Figure 2. Close-up of configuration switches (all sets are identical in appearance)

Configuration DIP Switch Set “S2”
Switches S1-1 through S1-8 may be used to configure CO/CP operation, line framing and coding, CRC-4 operation, and DTE initiated loop diag- nostics. Default settings of S1 switches are shown in Table 1.
Switch S2-1, S2-2, S2-3, S2-4, and S-5. Reserved for factory use and must remain in the OFF Position.
Switches S2-6 and S2-7: Clock Mode. Use Switches S2-6 and S2-7 to configure the 1088 for internal, external, or receive recover clock mode.
Switch S2-8: Enable/Disable Loop Tests from DTE. Switch S2-8 may be used to allow Model 1088/C to enter loopback diagnostic tests (Local or Remote) when the V.35 DTE raises the appropriate loop request pin (LLB: Pin L or RDL: Pin N). When Switch S2-8 is in the On position, the Model 1088/C will enter Local Loopback or Remote Loopback at the request of the DTE. When Switch S2-8 is in the Off position, the Model

1088/C ignores DTE loop requests. In the Off position, loop requests may still be initiated by the front panel switch.


Switch S3-8: Transmit Data (TD) Sampling Point. Switch 3-8 controls the Transmit Data (TD) sampling point.
The NetLink Plug-and-Play feature allows ISPs, carriers and PTTs to quickly upgrade the link speed for a customer without requiring the cus- tomer to re-configure the Customer Premise (CP) Model 1088. This fea- ture also allows service providers to set up all of the configurations at the Central Office (on the rack cards) before installing the stand alone units, saving time spent configuring or re-configuring DIP switches.
The NetLink Plug-and-Play feature allows the user to configure the DTE rate (bandwidth allocation, see Switches S3-1 through S3-6) of the CP unit from the rack card at the Central Office (CO). The stand alone unit at the Customer Premise (CP) site will automatically configure itself to the DTE rate (Bandwidth Allocation) of the rack card. Other configuration parameters remain in the default setting.
Follow the instructions below to activate NetLink Plug-and-Play between CO (Model 1095RC) and CP (Model 1088) units:
mode as defined by the application.
all S2 and S3 DIP switches in the ON position as described in Figure 3.
1095RC (CO)
DIP Switches all in ON position DIP Switches or NMS configured
according to specific application
Figure 3. Typical NetLink Plug-and-Play Application
DSL Span · requirements

When the CO and CP units connect over DSL, the CP will enter a pre- defined default configuration (Receive Recovered Clocking). During the negotiation process between the units, the CO unit will configure the DTE rate/line rate on the CP unit as defined by the settings of the CO unit. When additional bandwidth is required, only the configuration of the CO unit should be changed. This feature gives ISPs, LECs and PTTs the ability to provision bandwidth on an as-needed basis to customers.

Once the Model 1088 is properly configured, it is ready to connect to the twisted pair interface, to the serial port, and to the power source. This section tells you how to make these connections.
The Model 1088 supports communication between two DTE devices at distances to 5 miles (8 km) over 24 AWG (.5 mm) twisted pair wire. Two things are essential:
DSL span must be set for the same DTE rate.
metallic wire. This twisted pair must be unconditioned, dry, metallic wire, between 19 (.9mm) and 26 AWG (.4mm) (the higher number gauges will limit distance). Standard dial-up telephone circuits, or leased circuits that run through signal equalization equipment, or standard, flat modular telephone type cable, are not acceptable.
The RJ-45 connector on the Model 1088’s twisted pair interface is polar- ity insensitive and is wired for a two-wire interface. The signal/pin rela- tionships are shown in Figure 4.
1 (N/C) 2 (N/C) 3 (N/C) 4 (2-Wire TIP) 5 (2-Wire RING) 6 (N/C) 7 (N/C) 8 (N/C)
1 2 3 4 5 6 7 8
Figure 4. Model 1088 RJ-45 twisted pair line interface.
Model 1088/C supports V.35 serial port connections. This section describes how to connect the serial ports to your V.35 equipment.
Connecting the Model 1088/C (V.35) to a “DTE” Device
The Model 1088/C provides a V.35 DCE (Data Circuit Terminating Equip- ment) interface on an M/34 female connector. As a DCE, this interface is designed to connect to DTE equipment, such as a router. When connect- ing the V.35 interface of the Model 1088/C to your DTE device, use a

V.35 straight through cable (See Figure 5). Appendix C describes pin assignments and signal sources for the Model 1088/C V.35 interface. When purchasing or constructing an interface cable, please refer to the pin diagrams in Appendix C as a guide.
V.35 Router (DTE)
Figure 5. Connecting the Model 1088/C to V.35 Serial DTE
Connecting the Model 1088/C (V.35) to a “DCE” Device
The Model 1088/C provides a V.35 DCE (Data Circuit Terminating Equip- ment) interface on an M/34 female connector. As a DCE, this interface is designed to connect to DTE equipment, such as a router. However, tail- circuit applications require connection to another DCE equipment, such as a multiplexer. When connecting the V.35 interface of the Model 1088/ C to your DCE device (see Figure 6), use a V.35 null modem cable. Some applications may also require the installation of a V.35 tail-circuit buffer to account for small differences in clock frequency between the 1088/C and the V.35 DCE (Multiplexer).
V.35 Multiplexer (DCE)
Figure 6. Connecting the Model 1088/C to V.35 Serial DCE
Model 1088/D supports X.21 serial port connections. This section describes how to connect the serial ports to your X.21 equipment.
Connecting the Model 1088/D (X.21) to a “DCE” or “DTE” Device
The Model 1088/D provides an X.21 interface on a DB-15 female con- nector. The X.21 interface default configuration is DCE (Data Circuit Ter- minating Equipment) for connection to DTE (Data Terminal Equipment)

such as a router. However, the X.21 interface on the Model 1088/D may be configured as DTE (Data Terminal Equipment) for connection to DCE such as a modem or multiplexer. When connecting the X.21 interface of the Model 1088/C to your DTE device, use a X.21 straight through cable (See Figure 7).
Model 1088/D (DCE or DTE)
Figure 7. Connecting the Model 1088/D to X.21 DTE or DCE
To change the DCE/DTE orientation from the default position (DCE), you must open the case Model 1088/D case.
To open the Model 1088/D case, insert a flat head screw driver into an open slot on both sides of the case, as in Figure 8. Twist the screw driver head slightly and the top half of the case will separate from the lower half, as in Figure 8. Be careful not to damage the PC-board mounted components.
Figure 8. Opening the 1088 Case with a Small Screwdriver

The DCE/DTE strap is located on the top side of the 1088/D pc board (See Figure 9, below). The arrows on the top of the strap indicate the configuration of the X.21 port (for example, if the DCE arrows are point- ing toward the DB-15 connector, the X.21 port is wired as a DCE). Change the DCE/DTE orientation by pulling the strap out of its socket, rotating it 180º, then plugging the strap back into the socket. You will see that the DCE/DTE arrows now point in the opposite directions, showing the new configuration of the X.21 port. To close the case, fit the 2 halves together snugly and snap them back in place.

DCE/DTE Strap DB-15 Connector
Figure 9. Setting the DCE/DTE Strap
The Model 1088 (all versions) are available with Universal AC (100- 240VAC), 120VAC, 230VAC or -48VDC power options. This section describes these options.
Universal AC Power (100–240 VAC)
The Model 1088 uses a 5 VDC, 2A universal input 100–240 VAC, power supply (center pin is +5V). The universal input power supply has a male IEC-320 power entry connector. This power supply connects to the Model 1088 by means of a barrel jack on the rear panel. Many interna- tional power cords are available for the universal power supply (Please refer to Appendix B for country-specific power cords.
The Model 1088 powers up as soon as it is plugged into an AC outlet-- there is no power switch.

120 VAC Power (US)
The 100–132 VAC adapter supplied with the U.S. version of the Model 1088 is a wall mount type and may be plugged into any approved 120 VAC wall jack.
230 VAC Power (International)
The 230 VAC adapter supplied with the International version of the Model 1088 is a wall mount type and may be plugged into any approved 230 VAC wall jack.
The 36-60 VDC DC to DC adapter is supplied with the DC version of the Model 1088. The black and red leads plug into a DC source (nominal 48VDC) and the barrel power connector plugs into the barrel power sup- ply jack on the rear panel of the 1088. (See Figure 10).
To Power Supply Jack To -48VDC
OUTPUT : +5V 1.0A
INPUT : 36-60V 0.2A MAX
MODEL : SYD1106-0505
SWITCHING POWER SUPPLY
MADE IN CHINA BY SUNNY
S/N : G01234567890
Figure 10. Connecting DC Power to the 48V-PSM DC Power Supply
There are no user-serviceable parts in the power supply section of the Model 1088. Fuse replacement should only be performed by qualified service personnel. Con- tact Patton Electronics Technical support at (301)975- 1007, via our web site at http://www.patton.com or by e-mail at support@patton.com, for more information.

Once the Model 1088 is properly configured and installed, it should oper- ate transparently. This sections describes power-up, reading the LED status monitors, and using the built-in loopback test modes.
To apply power to the Model 1088, first be sure that you have read sec- tion 4.4, “Connecting Power” on page 16, and that the unit is connected to the appropriate power source. Then power-up the unit.
The Model 1088 features six front panel LEDs that monitor power, the DTE signals, network connection and test modes. Figure 11 shows the front panel location of each LED. Following Figure 11 is a description of each LED’s function. See also, LED description chart on page 19.

Figure 11. Model 1088/K Front Panel
(Active Green) Solid green (On) indicates that the end to end DSL Framer Link is up, signifying that the link across the DSL span is active. The DSL Link LED is Off when the link is down.
Glows yellow to indicate an idle condition of Binary “1” data on the respective terminal interface signals. Green indicates Binary “0” data
(No Signal) Glows red to indicate that the local Model 1088 is not connected with the remote Model 1088.
DSL Link

Glows yellow to indicate that the Model 1095 has been placed in Test Mode. The unit can be placed in test mode by the local user or by the remote user. The TM LED will flash for 400msec when a valid packet is received from the Model 1001MC.
Model 1088 LED Descriptions Chart
Clock (CO) Internal 768Kb No DTE Clock (CP) R/R No DTE
TD RD DSL NS ER TM TD RD DSL NS ER TM
Power ON G O off ON off off O O off ON off off
DSL Link G O G off off off O G G off off off
Link Brk G O off O O off
Brk+ 10s G G off ON off off O O off ON off off
RDL G G G off off ON O G G off off ON
RDL+511 G G off off off ON O G off off off ON
With DTE Connected With DTE Connected
Mark O O G off off off O O G off off off
Space G G G off off off G G G off off off
Data GO GO G off off off GO GO G off off off
Link Brk = DSL Link Broken Brk+10s = 10 Seconds following Link Break G=GREEN O=ORANGE ON= ON off= OFF Y=yellow
Figure 12. LED descriptions chart
The Model 1088 offers two proprietary loopback test modes, plus a built- in V.52 BER test pattern generator to evaluate the condition of the modems and the communication link. These tests can be activated phys- ically from the front panel or via the DTE interface.

Figure 13 shows the major elements used in the loop-back and pattern tests available in the Model 1088. Each block has several functions. Fol- lowing Figure 13 are descriptions that show how the elements are used during Test Modes.
Figure 13. Block Diagram Model 1088
The framer is used to determine the status of the line. In normal operation the framer transmits and expects to receive framed packets from the far end. If the framer receives framed packets from the far end, CTS and CD will be active. If framed packets are not received, CTS and CD will be inactive. The restart pro- cedure uses this information to determine if a valid connection is made (cable disconnect, poor cable quality, etc). In normal Data Mode, if the Model 1088 receives 4 seconds of unframed packets it will restart and begin trying to re-establish a connec- tion with the far end. The distinction between framed packets and unframed packets becomes important when we discuss the Pattern Generator.
This part of the Processor generates and detects the 511/511E patterns. When transmitting 511 patterns, the information is unframed (because it originates after the framer) and is intended to be evaluated only by another Processor. If the units are in Data Mode and the pattern generator is enabled on one end of the link, the far end will begin receiving unframed packets and assume that the line has gone down. During test modes, we force the pattern generator to time out before it can cause the link to be killed.
This part of the Processor is used to control loop-backs. In a Local Loop, the data is looped back towards the local DTE. In a Remote Loop, the data is looped back to the line, but it is also allowed to pass through to the framer and to the remote DTE.
Restart Procedure and Time Outs
The restart procedure is in place to allow the units to re-estab-

lish a connection after the framer begins seeing unframed pack- ets. The Test Model Timing Chart below shows the amount of time the framer must see consecutive unframed packets before the unit will restart and try to establish a new line connection. The reason that there are different Restart Times will become apparent after reading the rest of the document. The 511/511E Time Out shown refers to the amount of time the 511/511E pat- tern will be valid. At the end of this time the pattern will automat- ically turn itself off and the normal data path will be re- established. The ER led will flash indicating to the user that the test has timed out. The ER led will stop flashing once the 511/ 511E switch is placed into the normal position.
Item Elapsed Time (seconds) Start Up 50 Data Mode 4 511/511E Generator Enabled 60 (The generator will stop after 45 seconds.) Remote End of an RDL 60 511/511E Time Out 45 (The pattern generator will automatically turn off after 45 seconds. The ER LED will flash until the user turns off the 511/511E switch.)
This symbol designates the origination or the termination of a data path. The direction of the arrow connected distinguish the two data paths.
This symbol designates an invalid data path. If there is data present it should be ignored.
Symbol Indicators · Test Mode Timing

The following section describes the Test Modes used in the Model 1088. At the bottom of each Test Mode, a figure is included to show the data path..
Figure 14. Block Diagram Local Loop Mode 1
Figure 15. Block Diagram Local Loop Mode 2
There are two different modes of operation for a Local Loop depending on the status of the units at the time that the Local Loop is initiated. If the units are not in linked (NS LED on) and the Local Loop is initiated, either by the front panel switch or the DTE interface, the unit will enter mode 1. If the units are linked, NS LED off, then the unit will enter a mode 2 Local Loop.
A Mode 1 Local Loop is shown in Figure 14. When the Local Loop is initiated, either by the front panel switch or the DTE interface, the loop will be activated within the local Processor. The data present at the local DTE interface will be looped back to the local DTE by the Loop Control block within the Processor. Any data present on the line or at the far end DTE interface is invalid. The remote unit will remain in the StartUP mode, NS LED on, CTS LED yellow, and CD LED yellow, until the local unit is taken out of the Local Loop mode. After the Local Loop is deselected, the units will both be in StartUP mode and the link will be established.
A mode 2 Local Loop is shown in Figure 15. When the Local Loop is initiated, either by the front panel switch or the DTE interface, two separate loop paths will be started. In the first path, data presented to the local DTE interface will be looped back to the local DTE within the framer. In the second path,

data presented at the far end DTE will be transmitted to the local DTE and then looped back within the local DTE Loop Con- trol block with the Processor. After the Local Loop is deselected, the units will be placed back into DataMode and the normal data paths will be re-established.
Figure 16. Block Diagram Local Loop Mode 1 with 511/511E
Figure 17. Block Diagram Local Loop Mode 2 with 511/511E
Local Loop with 511/511E
When the unit is placed into a Mode 1. Local Loop and the 511/ 511E pattern generator is activated, the local pattern generator begins sending out a 511/511E pattern to the Loop Control block. The Loop Control block will loop this data back to the 511/ 511E pattern detector block, which will evaluate the data for errors. Because the 511/511E pattern generator is contained within the Processor the data is unframed so the framer will begin seeing unframed packets. The framer receives this unframed data and can not distinguish this information from a line disconnection (this would cause the units' Restart proce- dure to start). What we have done to allow this mode to work is to add time outs for the pattern generators. When the 511/511E is initiated, the line restart procedure is changed to one minute. The 511/511E pattern will timeout after 45 seconds. So if the 511/511E is turned on during a local loop, the restart procedure is set to one minute, but the 511/511E pattern will time out after 45 seconds, allowing the framer to begin seeing framed pack- ets (and not restart the box).
After the 511/511E pattern times out, the ER led will begin flashing. It will remain this way until the pattern generator switch is turned off. Note that the data at the local DTE and the remote

DTE are not valid. Because the data is unframed there is no way for the framer to send this data out to the DTE. This is an important distinction because other Patton units will send out the 511 pattern.
When the unit is placed into a Mode 2 Local Loop, the 511/511E pattern generator on the local unit is unavailable for transmis- sion. As can be seen from Figure 11, the 511/511E pattern gen- erator has no data path connections available. The 511/511E pattern generator is still available on the remote unit. For more information on the proper operation of this pattern generator please refer to the "Remote Digital Loop with 511/511E" sec- tion.
Figure 18. Block Diagram Remote Loop
The Remote Loop uses the EOC channel (an out-of-band sig- naling channel) to establish the remote link. Upon the RDL switch being thrown or DTE initiation, a RDL_ON Request sig- nal is sent to the remote unit. The Remote unit then responds with an RDL Acknowledge command and the link is established. Data originates at the local DTE and is looped at the Remote PROCESSOR back to the Local DTE. Note that the data is also passed through to the Remote DTE and is not squelched. When a Remote unit enters RDL, it changes its' Restart timeout to one minute (the reason will be explain in the RDL with 511/511E section). If the line is disconnected, the local unit will Restart (NS led activated) after 4 - 6 seconds, but the Remote unit will wait for one minute before it Restarts. Note that the transmit data at the Remote DTE is ignored. When the switch is thrown or the DTE removes the RDL request, the local unit will transmit an RDL_OFF Request to the Remote unit. The local unit will keep its' TM led active until this request has been completely sent out. If the switch is thrown again before the completion of the termination phase the switch will be ignored until it is placed back into the normal position.

Figure 19. Block Remote Loop with 511/511E
Remote Digital Loop with 511/511E
The Remote Digital Loop with 511/511E is shown above. After RDL is established the Remote units' Restart Timer is set to one minute. This has been done because when the 511/511E gen- erator is started on the local unit, the Remote framer begins seeing unframed packets. The Remote unit can not distinguish the 511/511E pattern from the line being disconnected so the Restart Timer has been lengthened to allow the pattern genera- tor to function. Once the 511/511E test is started, the Local unit changes its' Restart Timer to one minute. The pattern originates within the Processor and is sent to the Remote unit. It is then looped back to the Local unit where it is evaluated for errors. After 45 seconds, the Pattern Generator will timeout and stops sending the pattern. The ER led will begin blinking until the user turns off the 511/511E switch.
Figure 20. Block Diagram DataMode with 511/511E
Data Mode with 511/511E Pattern Generators
When the units enter DataMode it is possible to turn on the 511/ 511E pattern generators on both ends of the link. Once a 511/ 511E pattern is selected on one end of the link, the pattern gen- erator will begin transmitting unframed 511/511E through the line to the Remote end. A possible problem with this test can occur due to the Restart procedure. Once the Local 511/511E is turned on, the Remote unit begins receiving an unframed 511 pattern. If the Remote unit does not turn on the 511/511E-pat- tern generator within 4 seconds, the Remote unit will Restart and enter the StartUp mode. Note that once the 511/511E-pat- tern generator is started the Restart timer is changed to one minute (only on the unit which has the pattern enabled). If both

units enable the 511/511E pattern within 4 seconds of each other, both units will be transmitting and receiving the 511/511E pattern. Both framers are now receiving unframed data and will restart after one minute. The 511/511E pattern generators will TimeOut after 45 seconds re-enabling the normal data path. The ER led will begin flashing until the user terminates the test.
Using the V.52 (BER) Test Pattern Generator
To use the V.52 BER tests in conjunction with the Remote Digital Loop- back tests (or with Local Line Loopback tests), follow these instructions:
and move it UP. This activates the V.52 BER test mode and trans- mits a “511” test pattern into the loop. If any errors are present, the local modem’s red “ER” LED will blink sporadically.
gle switch DOWN, activating the “511/E” test with errors present. If the test is working properly, the local modem's red “ER” LED will glow. A successful “511/E” test will confirm that the link is in place, and that the Model 1095’s built-in “511” generator and detector are working properly.
Note The above V.52 BER tests can be used independently of the Remote Digital Loopback tests. This requires two operators: (1) to initiate and monitor the tests at the local Model 1088, and (2) to do the same at the remote Model 1088. In this case, the test pattern sent by each Model 1088 will not be looped back, but will be transmitted down the line to the other Model 1088. While one operator initiates test, the other monitors for errors.

A.1 CLOCKING MODES
Internal, External, or Receive Recovered
All 64k steps from 64 to 2304 kbps
V.35 (Model 1088/C), DCE Orientation;
X.21 (Model 1088/D), DCE or DTE Orientation depending upon orienta- tion of PC-board mounted daughter board
M/34 Female (Model 1088/C)
D-Sub-15 Female (Model 1088/D)
V52 compliant (511/511E) pattern generator and detector with error injection mode con-trolled by front panel switch, Local and Remote Loop- back control by either a front panel switch or from the DTE interface
The following LEDs are displayed on the front panel:
Externally accessible dip switches or SNMP managed through 1095RC

+5 VDC external desk top power supply, 90-260VAC, 50-60 Hz (Univer- sal Input), 10W or -48 VDC
FCC Part 15, CE, CTR1
A.11 LINE CODING
CAP (Carrierless Amplitude and Phase Modulation
144, 272, 400, 528, 784, 1040, 1552, 2064, 2320 kpbs
Transformer coupled, 1500 VAC isolation
RJ-45, 2 wire, polarity insensitive pins 4 and 5
Operating temperature 0–50°C; humidity 5–95% non-condensing; alti- tude, 0–15,000 feet (0–4,600 m)
Single Twisted Pair

1088/C V.35 mDSL Rocket (CAP) 1088/D X.21 mDSL Rocket (CAP) 080551 120V Power Supply 080552 230V Power Supply 48V-PSM DC Power Supply Module 08055DCUI 100-240VAC (+5V ±5% reg. DC/2A) Universal Input Adapter 0805EUR European Power Cord CEE 7 (“A”) 0805UK United Kingdom Power Cord (“D”) 0805US American Power Cord (“K”) 0805AUS Australia/New Zealand Power Cord (“C”) 0805DEN Denmark Power Cord (“E”) 0805FR France/Belgium Power Cord (“F”) 0805IN India Power Cord (“G”) 0805IS Israel Power Cord (“H”) 0805JAP Japan Power Cord (“J”) 0805SW Switzerland Power Cord (“L”) 07M1088/C User Manual
Model # Description

V.35 Interface (M/34 Female Connector)
B SGND (Signal Ground) C RTS (Request to Send) (DTE Source) D CTS (Clear to Send) (DCE Source) E DSR (Data Set Ready) (DCE Source) F CD (Carrier Detect) (DCE Source) H DTR (Data Terminal Ready) (DTE Source) L LLB (Local Line Loop) (DTE Source) M TM (Test Mode) (DTE Source) N RDL (Remote Digital Loop) (DTE Source) P TD (Transmit Data) (DTE Source) R RD (Receive Data) (DCE Source) S TD/ (Transmit Data-B) (DTE Source) T RD/ (Receive Data-B) (DCE Source) U XTC (External Transmit Clock) (DTE Source) V RC(Receiver Clock) (DCE Source) W XTC/ (External Transmit Clock) (DTE Source) X RC/ (Receiver Clock) (DCE Source) Y TC (Transmitter Clock-A) (DCE Source) AA TC/ (Transmit Clock-B) (DCE Source)
(DCE Orientation) · Pin # Signal

X.21 Interface (D-Sub-15 Female Connector)
1 Frame Ground 2 T (Transmit Data-A) (DTE Source) 3 C (Control-A) (DTE Source) 4 R (Receive Data-A) (DCE Source) 5 I (Indication-A) (DCE Source) 6 S (Signal Element Timing-A) (DCE Source) 7 BT (Byte Timing-A) (DCE Source) 8 SGND (Signal Ground) 9 T/ (Transmit Data-B) (DTE Source) 10 C/ (Control-B) (DTE Source) 11 R/ (Receive Data-B) (DCE Source) 12 I/ (Indication-B) (DCE Source) 13 S/ (Signal Element Timing-B) (DCE Source) 14 BT/ (Byte Timing-B) (DCE Source)
(DTE /DCE Orientation) · Pin # Signal

APPENDIX E MODEL 1088/C AND 1088/D TRANSMISSION DISTANCE CHART
Transmission Distance - Patton NetLink Model 1088
No Cross Talk 26 AWG (0.4mm) 24 AWG (0.5mm)
Line Rate DTE Rates kbps feet miles km feet miles km 144 64, 128 21400 4.0 6.6 30700 5.8 9.4 272 192, 256 20300 3.8 6.2 30600 5.8 9.4 400 320, 384 18600 3.5 5.7 29100 5.5 9 528 448, 512 17400 3.3 5.4 26100 4.9 8.0 784 576, 640, 704, 768 15800 3.0 4.9 22600 4.3 7.0 1040 832, 896, 960, 102415500 2.9 4.8 22100 4.2 6.8 1552 1088 - 1536 13600 2.6 4.2 19200 3.6 5.9 2064 1600 - 2048 12200 2.3 3.8 17200 3.3 5.3 2320 2112 - 2304 11500 2.2 3.5 15800 3.0 4.9
Cross Talk (49 adjacent CAP pairs) 26 AWG (0.4mm) 24 AWG (0.5mm)
Line Rate DTE Rates kbps feet miles km feet miles km 144 64, 128 16992 3.2 5.2 25000 4.7 7.7 272 192, 256 15088 2.9 4.6 22000 4.2 6.8 400 320, 384 13264 2.6 4.2 20000 3.8 6.2 528 448, 512 12300 2.3 3.8 18000 3.4 5.5 784 576, 640, 704, 768 10216 1.9 3.1 14000 2.6 4.3 1040 832, 896, 960, 1024 8417 1.6 2.6 12000 2.3 3.7 1552 1088 - 1536 7107 1.3 2.2 10000 1.9 3.1 2064 1600 - 2048 5920 1.1 1.8 8000 1.5 2.5 2320 2112 - 2304 5416 1.0 1.7 73000 1.4 2.2
Copyright © 2000, 2006 Patton Electronics Company