MODEL 1005 and 1005S Async. Carrier Sense Short Range Modem

Part #07M1005-C Doc. #052031UC Revised 4/29/98
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com
An ISO-9001 Certified Company

1.3 SERVICE
Patton Electronics warrants all Model 1005 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
telephone: (301) 975-1007, web address: http://www.patton.com email: support@patton.com.
Patton Electronics’ technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1005. Technical Service hours: 8AM to 5PM EST, Monday through Friday.
The Model 1005 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 1005 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1005 does cause interference to radio or television reception, which can be determined by disconnecting the modem, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Patton Technical Support.

3.0 CONFIGURATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007.
The Model 1005 is designed to be easy to use. There are no internal jumpers or configuration switches to set, so there is no need to open the case to configure the unit (you may need to open the case for wire connection—refer to Section 4.0). The only configuration necessary for operation is proper setting of the external DCE/DTE switch.
The figure below shows the location of the DCE/DTE switch on the PC board, as well as the location of the terminal block and surge suppressors (“S” model only).


Surge Suppressors (1005S only)
The Patton Model 1005 Carrier Sense Short Range Modem allows RS-232 UNIX systems to communicate up to 17 miles (27.2 km) over two unconditioned twisted pair cable. Supporting data rates to 19.2 Kbps, the Model 1005 requires no AC power or batteries.
For your convenience, the Model 1005 has an externally accessible DCE/DTE switch (see diagram below). If the device connected to the Model 1005 is a modem or multiplexer (or is wired like one), set the switch to “DTE”. This setting causes the Model 1005 to behave like Data Terminal Equipment and transmit data on pin 2.
The Model 1005 has a unique carrier sense feature, which automatically detects the presence of a carrier on the line. This is particularly useful in UNIX environments, where the host must see a carrier before it sends a logon screen to the terminal. This feature also plays an important role in troubleshooting, where the presence or absence of a carrier indicates positive or negative line integrity.
Measuring only 2.66” x 2.10” x .73” (6.76 x 5.33 x 1.85 cm), the Model 1005 is housed in a pop-open ABS plastic case. The Model 1005 comes with a male or female DB-25 connector and a choice of interfaces (RJ-11 jack, RJ-45 jack, or terminal blocks with strain relief). For surge handling capability, the Model 1005S is compliant with IEC 801.5 level 2, 1kV.
If the device connected to the Model 1005 is a PC, terminal, or host computer (or is wired like one), set the switch to “DCE”. This setting causes the Model 1005 to behave like Data Communications Equipment and transmit data on pin 3.
Switch · Terminal · Block

RJ-1 1 SIGNAL RJ-45 SIGNAL
Once you have properly configured the DCE/DTE switch, you are ready to connect the Model 1005 to your system. This section tells you how to connect the Model 1005 to the twisted pair and RS-232 interfaces, and how to operate the Model 1005.
3----------------XMT+ 3----------------RCV4----------------XMT4----------------XMT+ 5----------------RCV+ 5----------------XMT6----------------GND † 6----------------RCV+ 7----------------GND †
4.1 CONNECTION TO THE TWISTED PAIR INTERFACE
The Model 1005 supports data-only communication between two RS-232 devices at distances to 17 (27.2 km) miles and data rates to 19.2 Kbps. There are two essential requirements for installation:
When connecting two Model 1005s, it is necessary to use a “crossover” cable. The diagram below shows how a crossover cable should be constructed for an environment where both Model 1005s use a 4-wire RJ-11 connector. Similar logic should be followed when using RJ-45 connectors or a combination of the two.
GND† 1 Blue White 6 GND†
RCV- 2 Yellow Red 4 XMT- XMT+ 3 Green Black 5 RCV+ XMT- 4 Red Yellow 2 RCV- RCV+ 5 Black Green 3 XMT+ GND† 6 White Blue 1 GND†
For your convenience, the Model 1005 is available with three different twisted pair interfaces: RJ-11 jack, RJ-45 jack and terminal blocks with strain relief.
†Connection to ground is optional
‡Standard color codes—yours may be different
The RJ-11 and RJ-45 connectors on the Model 1005's twisted pair interface are pre-wired for a standard TELCO wiring environment (see Figure 1). The table on the following page shows the signal/pin relationships.
If your RS-232 application requires you to connect two pairs of bare wires to the Model 1005, you will need to open the case to access the terminal blocks. The following instructions will tell you how to open the case, connect the bare wires to the terminal blocks, and fasten the strain relief collar in place so that the wires won't pull loose.


Figure 1. AT&T standard modular color codes

Once the unit has been opened, you will be able to see the terminal blocks located at the rear of the PC board.

Ultimately, you will want to construct a two pair crossover cable that connects the two short hauls as shown below:

XMT + RCV+ XMT - RCV - G G RCV - XMT - RCV + XMT +







Once you have configured the Model 1005 for DTE or DCE and connected the twisted pair wires correctly, simply plug the 1005 directly into the DB-25 port of the RS-232 device. After doing so, remember to insert and tighten the two captive connector screws.
Once the Model 1005 is properly installed, it should operate transparently—as if it were a standard cable connection. Operating power is derived from the RS-232 data and control signals; there is no “ON/OFF” switch.

APPENDIX B
PATTON MODEL 1005 SPECIFICATIONS
PATTON MODEL 1005 CABLE RECOMMENDATIONS
The Patton Model 1005 operates at frequencies of 20kHz or less and has been performance tested by Patton technicians using twisted- pair cable with the following characteristics:
Wire Gauge Capacitance Resistance
the terminal raises RTS (Pin 4); DSR (Pin 6) turns on when is powered-up (connected); DCD (Pin 8) turns ON after detecting the receive signal from the line; DTE Mode: RTS (Pin 4) turns “ON” immediately after the modem raises CTS (Pin 5); DTR (Pin 20) turns "ON" after recognizing the receive signal from the line; Pins 11, 19 and 20 are hardwired together on the DB-25 side of the DCE/DTE switch
19 AWG/.9mm 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft. 22 AWG/.6mm 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft. 24 AWG/.5mm 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.
To gain optimum performance from the Model 1005, please keep the following guidelines in mind:
(4 wires and 1 ground) and a strain relief insert
from EIA data and control signals; additional power can be added at pin 9 for +V DC when DB-25 is below the RS-232 standard requirements
Model 1005 Distance Table in Miles (km)
1005S Only)

APPENDIX D
PATTON MODEL 1005 PIN/SIGNAL ASSIGNMENTS
PATTON MODEL 1005 BLOCK DIAGRAM
DIRECTION STANDARD “DCE” SETTING DIRECTION



Copyright © 1998 Patton Electronics Company
All Rights Reserved
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.