MODEL 1040 Self-Powered Universal Short Range Modem

Patton electronic 1040 — USER MANUAL diagram (page 1)
Fig. 1

Part #07M1040-B Doc. #054011UB Revised 4/29/98

SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

An ISO-9001 Certified Company

Page 2 of the Patton electronic 1040 user manual — 1.2 CE NOTICE
Page 2 · click to enlarge
Page 2

1.0 WARRANTY INFORMATION

1.3 SERVICE

Patton Electronics warrants all Model 1040 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at

This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

telephone: (301) 975-1007, web address: http://www.patton.com; email: support@patton.com.

Patton Electronics’ technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1040. Technical Service hours: 8AM to 5PM EST, Monday through Friday.

1.1 RADIO AND TV INTERFERENCE

The Model 1040 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 1040 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1040 does cause interference to radio or television reception, which can be determined by disconnecting the RS-232 interface, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.2 CE NOTICE

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Patton Technical Support.

Page 3 of the Patton electronic 1040 user manual — SW1 SW2
Page 3 · click to enlarge
Page 3

2.0 GENERAL INFORMATION

3.0 CONFIGURATION

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007.

The Model 1040 is simple to install and is ruggedly designed for excellent reliability: just set it and forget it. The following instructions will help you set up and install the Model 1040 properly. If you have any questions, don’t hesitate to call Patton Electronics Technical Support at (301) 975-1007.

2.1 FEATURES

3.1 CONFIGURATION SWITCHES

  • Switch-selectable carrier control
  • Synchronous or asynchronous operation
  • No AC power or batteries required
  • Data rates to 38.4 Kbps
  • Distances to 12 miles (19.2 km)
  • Point-to-point or multipoint operation
  • Full or half duplex operation
  • Internal, external or received loopback clocking
  • V.54 loopback tests and V.52 compliant BER tests
  • Automatic equalization
  • Easy-to-read status LEDs
  • Transformer isolation
  • Silicon Avalanche Diode surge protection

The Model 1040 uses a unique set of sixteen external DIP switches that allow configuration to an extremely wide range of applications. These DIP switches are grouped into two eight-switch sets and are externally accessible from the underside of the Model 1040 (see Figure 1). There is no need to open the Model 1040’s case for configuration.

The configuration switches allow you to select data rates, clocking methods, V.52 & V.54 tests, word lengths, extended signaling rates, asynchronous or synchronous mode and 2- or 4-wire mode. The drawings, text and tables on the following pages describe all switch locations, positions and functions.

Patton electronic 1040 — 2.1 FEATURES diagram (page 3)
Fig. 2
Patton electronic 1040 — 2.1 FEATURES diagram (page 3)
Fig. 3

2.2 DESCRIPTION

The Model 1040 carrier controlled short range modem supports synchronous and asynchronous data rates to 38.4 Kbps. Requiring no AC power or batteries, the Model 1040 supports distances to 12 miles over unconditioned twisted pair. The Model 1040 features front panel LEDs, automatic equalization, V.52 compliant BER tests, both internal and external clocking and V.54 loopback tests. Built-in transformer isolation and surge protection provide protection against ground potential differences and AC/DC over-voltages.

SW1 SW2

The Model 1040 is fully compatible with the Patton Model 1080A and 1080ARC. This compatibility allows you to combine miniature, standalone and rack mounted modems in a single system. In synchronous mode, the Model 1040 is also compatible with the Models 1020, 1025 and 1030.

Housed in an ABS plastic case, the Model 1040 comes with either a male or female DB-25 connector and a choice of interfaces (RJ-11 jack, RJ-45 jack or terminal blocks with strain relief).

Figure 1. The back of the Model 1040

Page 4 of the Patton electronic 1040 user manual — 3.3 SWITCH SET SW1
Page 4 · click to enlarge
Page 4
SW1-1 through SW1-4Data Rate Setting

3.2 CONFIGURATION SWITCH SETTINGS

The Model 1040 has two sets of eight switches, yielding 16 total DIP switches. The two sets will be referred to as SW1 and SW2. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions.

Switches SW1-1 through SW1-4 are set in combination to determine the asynchronous and synchronous data rate for the Model 1040.

SW1-1 SW1-2 SW1-3 SW1-4 Setting On 1.2 Kbps Off On On On 1.8 Kbps On Off On On 2.4 Kbps Off Off On On 3.6 Kbps On On Off On 4.8 Kbps Off On Off On 7.2 Kbps On Off Off On 9.6 Kbps Off Off Off On 14.4 Kbps On On On Off 19.2 Kbps Off On On Off 28.8 Kbps On On Off Off 38.4 Kbps

Patton electronic 1040 — 3.2 CONFIGURATION SWITCH SETTINGS diagram (page 4)
Fig. 4
Patton electronic 1040 — 3.2 CONFIGURATION SWITCH SETTINGS diagram (page 4)
Fig. 5

ON

OFF

Figure 2. Close up of configuration switches

3.3 SWITCH SET SW1

SW1-5 and SW1-6Clock Source

The DIP switches on SW1 set data rate, clock source, async./sync. mode and carrier control method. The default settings are summarized in the table below.

Switches SW1-5 and SW1-6 are set in combination to determine the clock source for the Model 1040.

SW1 SUMMARY TABLE PositionFunctionFactory Default SW1-1 SW1-2 SW1-3 SW1-4Data Rate Data Rate Data Rate Data RateOn Off } 9,600 bps Off On SW1-5 SW1-6Clock Source Clock SourceOn } Internal On SW1-7Async./Sync.On Async. SW1-8Carrier ControlOff Constantly On

SW1-5 SW1-6 Setting On On Internal transmit clock Off On Receive recover clock On Off External transmit clock

SW1-7Asynchronous/Synchronous Mode

The setting for switch SW1-7 determines whether the Model 1040 is in asynchronous or synchronous operating mode.

SW1-7 Setting On Asynchronous Off Synchronous

Page 5 of the Patton electronic 1040 user manual — 3.4 SWITCH SET SW2
Page 5 · click to enlarge
Page 5
SW1-8Carrier Control Method
SW2-3Extended Signaling Rate

The setting for switch SW1-8 determines whether the carrier is “constantly on” or “controlled by RTS”. This setting allows for operation in switched carrier, multipoint and/or hardware handshaking applications. Note: SW1-8 must be “ON” in all 2-wire applications.

The setting for switch SW2-3 determines the range of variability the Model 1040 “looks for” in asynchronous data rates (i.e., the actual variance from a given frequency level the Model 1040 will tolerate).

SW2-3 Setting Off -2.5% to +1% On -2.5% to +2.3%

SW1-8 Setting Off Constantly on On Controlled by RTS

SW2-4 and SW2-5RTS/CTS Delay

3.4 SWITCH SET SW2

The combined settings for switches SW2-4 and SW2-5 determine the amount of delay between the time the Model 1040 “sees” RTS and when it sends CTS. Options are no delay, 7mS and 53mS.

The DIP switches on SW2 set word length, extended signaling rate, RTS/CTS delay, 2-wire/4-wire and V.52/V.54 tests. The factory default settings for Switch Set SW2 are summarized in the table below.

SW2-4 SW2-5 Setting On On 7 mS Off On 53 mS On Off No delay Off Off No delay

SW2 SUMMARY TABLE PositionFunctionFactory Default SW2-1 SW2-2Word Length Word LengthOff } 10 bits Off SW2-3Extended SignalingOff -2.5% to +1% SW2-4 SW2-5RTS/CTS Delay RTS/CTS DelayOn } 7 mS On SW2-6 SW2-72/4 Wire 2/4 WireOn } 4-wire/full dpx Off SW2-8V.52/V.54 TestsOff Enabled
SW2-6 and SW2-72-Wire/4-Wire Mode Selection

The setting for switch SW2-6 determines whether the Model 1040 is operating in 2-wire or 4-wire mode. Note: SW1-8 must be ON in 2-wire mode.

SW2-6 SW2-7 Setting On On 4-wire (half duplex) On Off 4-wire (full duplex) Off On 2-wire (half duplex only)

SW2-1 and SW2-2Word Length

SW2-1 and SW2-2 are set in combination to determine the word length for asynchronous/synchronous data.

SW2-8V.52 and V.54 Diagnostic Tests

The setting for switch SW2-8 determines whether or not the Model 1040’s V.52 and V.54 tests will be enabled. To reset the V.54 circuit, set switch SW2-8 to the “ON” position, then back to the “OFF” position.

SW2-1 SW2-2 Setting Off On 8 bits On On 9 bits Off Off 10 bits On Off 11 bits

SW2-8 Setting On Disabled Off Enabled

Page 6 of the Patton electronic 1040 user manual — 4.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS
Page 6 · click to enlarge
Page 6

4.0 INSTALLATION

RJ-1 1 SIGNAL RJ-45 SIGNAL

Once the Model 1040 is properly configured, it is ready to connect to your system. This section tells you how to connect the Model 1040 to the twisted pair and RS-232 interfaces.

1 GND† 1 N/C 2 RCV◊ 2 GND†

3 XMT 3 RCV ◊

4 XMT 4 XMT 5 RCV 5 XMT 6 GND† 6 RCV 7 GND†

4.1 CONNECTION TO THE TWISTED PAIR INTERFACE

The Model 1040 supports data-only communication between two RS-232 devices at distances to 12 miles (19.2) and data rates to 38.4 Kbps. There are two essential requirements for installing the Model 1040:

8 N/C †Connection to ground is optional

◊The Model 1040 is not polarity sensitive

1. These units work in pairs . Therefore, you must have one Model 1040 (or a compatible model) at each end of a two twisted pair interface.

When connecting two Model 1040s, it is necessary to use a “crossover” cable. The diagram below shows how a crossover cable should be constructed for an environment where both Model 1040s use a 6-wire RJ-11 connector. Similar logic should be followed when using RJ-45 connectors or a combination of the two.

2. To function properly, the Model 1040 needs two twisted pairs of metallic wire. These pairs must be unconditioned , dry, metallic wire, between 19 and 26 AWG (the higher number gauges may limit distance somewhat). Standard dial-up telephone circuits or leased circuits that run through signal equalization equipment are not acceptable .

SIGNAL PIN# COLOR ‡ COLOR PIN# SIGNAL

GND† 1 Blue White 6 GND†

RCV◊ 2 Yellow Red 4 XMT XMT 3 Green Black 5 RCV XMT 4 Red Yellow 2 RCV RCV 5 Black Green 3 XMT GND† 6 White Blue 1 GND†

For your convenience, the Model 1040 is available with three different twisted pair interfaces: RJ-11 jack, RJ-45 jack and terminal blocks with strain relief.

4.1.1 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

†Connection to ground is optional

The RJ-11 and RJ-45 connectors on the Model 1040's twisted pair interface are pre-wired for a standard TELCO wiring environment (see Figure 5). The signal/pin relationships are shown on the table on the following page.

‡Standard color codes—yours may be different

◊The Model 1040 is not sensitive to polarity

4.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

Patton electronic 1040 — 4.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS diagram (page 6)
Fig. 6
Patton electronic 1040 — 4.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS diagram (page 6)
Fig. 7

If your application requires you to connect two pairs of bare wires to the Model 1040, you must open the case to access the terminal blocks. The instructions on the following pages will tell you how to open the case, connect the bare wires to the terminal blocks and fasten the strain relief collar in place so that the wires won't pull loose.

1. Blue 2 - Orange 3 - Black 4 - Red 5 - Green 6 - Yellow 7 - Brown 8 - Slate
1. Blue 2 - Yellow 3 - Green 4 - Red 5 - Black 6 - White

Figure 5. Standard AT&T color codes

Page 7 of the Patton electronic 1040 user manual — 4.0 INSTALLATION
Page 7 · click to enlarge
Page 7
1. Open the unit by gently inserting a screwdriver into the special pry slot on the plastic case (below). Don't worry about breaking the plastic, but make sure that you do not insert the screwdriver more than 1/4” into the enclosure, as you may damage the unit.
4. Connect one pair of wires to the two XMT (transmit) poles on the terminal block. The Model 1040 is not polarity sensitive, so either wire may connect to either pole.
5. Connect the other pair of wires to the two RCV (receive) poles on the terminal block.
Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 8

Ultimately, you will want to construct a two-pair crossover cable that makes a connection with the two Model 1040s as shown below:

Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 9

XMT RCV XMT RCV G G RCV XMT RCV XMT

Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 10
Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 11
6. If there is a shield around the telephone cable it may be connected to “G” on the terminal block. To avoid ground loops, we recommend connecting the shield at the computer end only. A ground wire is not necessary for proper operation of the Model 1040.
7. When you finish connecting the wires to the terminal block, the assembly should resemble the diagram below:

Once the unit has been opened, you will be able to see the terminal blocks located at the rear of the PC board.

Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 12
2. Strip the outer insulation from the twisted pairs about one inch from the end.
Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 13
Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 14
3. Strip back the insulation on each of the 2 twisted pair wires about .25”.
Patton electronic 1040 — 4.0 INSTALLATION diagram (page 7)
Fig. 15
Page 8 of the Patton electronic 1040 user manual — 4.2.2 CONNECTION TO A “DCE” DEVICE
Page 8 · click to enlarge
Page 8
Patton electronic 1040 — 4.2 CONNECTION TO THE RS-232 INTERFACE diagram (page 8)
Fig. 16
Patton electronic 1040 — 4.2 CONNECTION TO THE RS-232 INTERFACE diagram (page 8)
Fig. 17
8. Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly. Slide the assembly so that it is about 2 inches from the terminal posts and press together firmly. If your cable diameter is too small or too large for our strain relief, please contact our technical support. We have strain relief assemblies to accommodate most cable diameters.
Patton electronic 1040 — 4.2 CONNECTION TO THE RS-232 INTERFACE diagram (page 8)
Fig. 18
Patton electronic 1040 — 4.2 CONNECTION TO THE RS-232 INTERFACE diagram (page 8)
Fig. 19
11. Insert one captive screw through a saddle washer, then insert the entire piece through the hole in the DB-25 end of the case. Snap that side of the case closed. Repeat the process for the other side. This completes cable installation.
Patton electronic 1040 — 4.2 CONNECTION TO THE RS-232 INTERFACE diagram (page 8)
Fig. 20

4.2 CONNECTION TO THE RS-232 INTERFACE

Once you have connected the twisted pair wires correctly, simply plug the Model 1040 directly into the DB-25 port of the RS-232 device. After doing so, remember to insert and tighten the two captive connector screws.

9. Insert the strain relief assembly with the wire going through it into the slot in the bottom half of the modem case and set it into the recess in the case.

4.2.1 CONNECTION TO A “DTE” DEVICE

The Model 1040 is wired as a DCE, and therefore “wants” to plug into a DTE such as a terminal, PC or host. Because the Model 1040 is interface powered, a direct connection to the RS-232 DTE port is most desirable. If you must use a cable to connect the Model 1040 to the DTE port, make sure it is a straight through cable of the shortest possible length—we recommend 6 feet or less.

Patton electronic 1040 — 4.2.1 CONNECTION TO A “DTE” DEVICE diagram (page 8)
Fig. 21
Patton electronic 1040 — 4.2.1 CONNECTION TO A “DTE” DEVICE diagram (page 8)
Fig. 22

4.2.2 CONNECTION TO A “DCE” DEVICE

Since the Model 1040 is wired as a DCE, you cannot connect it directly to another DCE such as a modem, multiplexer or printer. If you need to connect the Model 1040 to another DCE device, you must use a null modem cable wired according to diagram below. We recommend a cable of the shortest possible length, preferably 6 feet or less.

10. BEND the top half of the case as necessary to place it over the strain relief assembly. Do not snap the case together yet.
Page 9 of the Patton electronic 1040 user manual — S/N 123456
Page 9 · click to enlarge
Page 9

5.0 OPERATION

Connection to Model 1040 † Connection to DCE Device DB-25 Pin No. DB-25 Pin No.

Once the Model 1040 is properly configured and installed, it should operate transparently—as if it were a standard cable connection. Operating power is derived from the data and control signals; there is no “ON/OFF” switch. Section 5.0 describes reading the LED status monitors, powering-up and using the built-in V.52 and V.54 test modes.

1 1 2 3 3 2 4 8 8 4 6 20 20 6 17 24 24 17 7 7

5.1 FRONT PANEL aSWITCHES

During normal operation, both front panel switches should be in the “normal” center position. To operate a test mode, see Section 5.3.

†Note: When connected to another DCE device, the Model 1040 should be configured for “external clock” (see Section 3.3).

5.2 LED STATUS MONITORS

The Model 1040 features 2 front panel LEDs that indicate the condition of the V.52 and V.54 test modes. Figure 6 shows the location of each LED. Section 5.3 describes each LED’s function in more detail.

5.3 V.54 TEST MODES

The Model 1040 offers two V.54 test modes to evaluate the condition of the modems and the communication link. These tests can be activated physically from the front panel, or via the RS-232 interface. Note: V.54 test modes on the Model 1040 are available for point-to- point and 4-wire applications only.

BERT LOOP

511/E RDL NORMAL 511 LAL

MODEL 1040 Miniature Async./Sync. Modem

S/N 123456

Figure 6. Model 1040’s LED indicators and test switches

Gaithersburg, Maryland

Page 10 of the Patton electronic 1040 user manual — 5.4 POWER-DOWN
Page 10 · click to enlarge
Page 10

5.3.1 Local Analog Loopback (LAL)

5.3.3 Using the V.52 BER Test Independently

The Local Analog Loopback (LAL) test checks the operation of the local Model 1040, and is performed separately on each unit. Any data sent to the local Model 1040 in this test mode will be echoed (returned) back to the user device. For example, characters typed on the keyboard of a terminal will appear on the terminal screen. To perform a LAL test, follow these steps:

The V.52 BER test can be used independently of the V.54 loopback tests. This requires two operators: one to initiate and monitor the test at the local Model 1040, and one at the remote Model 1040. To use the V.52 BER test by itself, both operators should simultaneously follow these steps:

A. Activate LAL. This may be done in one of two ways: First, by

1. Locate the “511/511E” toggle switch on the front panel of the 1040 and move it DOWN. This activates the V.52 BER test mode and transmits a “511” test pattern to the other unit. If any errors are present, the receiving modem’s red “Error” LED will blink sporadically. Note: For this test to function, the “511” switch on both Model 1040s must be on.

moving the front panel toggle switch DOWN to “LAL”. Second, by raising pin 18 on the RS-232 interface (Note: Make sure DIP switch SW2-8 is OFF). Once LAL is activated, the Model 1040 transmit output is connected to its own receiver. The “test” LED should be lit.

B. Verify that the data terminal equipment is operating properly

2. If the test indicates no errors are present, move the V.52 toggle switch UP, activating the “511/E” test with periodic errors present. If the test is working properly, the receiving modem's red “Error” LED will light continuously. A successful “511/E” test will confirm that the link is in place, and that the Model 1040’s built-in “511” generator and detector are working properly.

and can be used for a test. If a fault is indicated, call a technician or replace the unit.

C. Perform a BER (bit error rate) test on each unit. If the BER

test equipment indicates no faults, but the data terminal indicates a fault, follow the manufacturer’s checkout procedures for the data terminal. Also, check the RS-232 interface cable between the terminal and the Model 1040.

5.4 POWER-DOWN

5.3.2 Remote Digital Loopback (RDL)

Turn off the Model 1040 by simply removing it from the circuit or by turning off the terminal that is directly connected to the Model 1040.

The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 1040s and the communication link between them. Any characters sent to the remote Model 1040 in this test mode will be returned back to the originating device. For example, characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote Model 1040 and looped back. To perform an RDL test, follow these steps:

A. Activate RDL. This may be done in two ways: first, by moving

the front panel toggle switch UP to “RDL”. Second, by raising pin 21 on the RS-232 interface (Note: Make sure SW2-8 is OFF).

B. Perform a BER (bit error rate) test on the system.

C. If the BER test equipment indicates a fault, and the Local

Analog Loopback test was successful for both Model 1040s, you may have a problem with the twisted pair line between the modems. Make sure you check the twisted pair line for proper connections and continuity.

Page 11 of the Patton electronic 1040 user manual — APPENDIX A
Page 11 · click to enlarge
Page 11

APPENDIX A

APPENDIX B

PATTON MODEL 1040 SPECIFICATIONS

PATTON MODEL 1040 CABLE RECOMMENDATIONS

Transmission Format: Sync. or async., full or half duplex Transmission Line: Unconditioned twisted pair 19 - 26 AWG Clocking: Internal, external or receive loopback Interfaces: EIA RS-232, CCITT V.24 Data Rates: 1.2, 1.8, 2.4, 3.6, 4.8, 7.2, 9.6, 14.4, 19.2, 28.8, 38.4 Kbps (switch selectable) Isolation: Minimum 1500 V RMS via isolation transformers Control Signals: Constantly “on” or controlled by RTS RTS/CTS Delay: No delay, 7mS, 53mS Connectors: DB-25 male or female on RS-232 side; RJ-11, RJ-45 or terminal block with strain relief on line side Power Supply: None required; uses power from EIA data and control signals Surge Protection: Compliant with IEC 801.5 level 2, 1kV Temperature Range: 0-60°C (32-140°F) Altitude: 0-15,000 feet Humidity: 5 to 95% noncondensing Dimensions: 3.0” x 2.1” x .81” (7.6 x 5.3 x 2.1 cm) Weight: 2 oz. (56.7g)

The Patton Model 1040 operates at frequencies of 20kHz or less and has been performance tested by Patton technicians using twisted- pair cable with the following characteristics:

Wire Gauge Capacitance Resistance

19 AWG/.9mm 83nf/mi or 15.72 pf/ft. .0163 Ohms/ft. 22 AWG/.6mm 83nf/mi or 15.72 pf/ft. .0326 Ohms/ft. 24 AWG/.5mm 83nf/mi or 15.72 pf/ft. .05165 Ohms/ft.

To gain optimum performance from the Model 1040, please keep the following guidelines in mind:

  • Always use twisted pair wire—this is not an option.
  • Use twisted pair wire with a capacitance of 20pf/ft or less.
  • Avoid twisted pair wire thinner than 26 AWG (i.e. avoid higher AWG numbers than 26)
  • Use of twisted pair with a resistance greater than the above specifications may cause a reduction in maximum distance obtainable. Functionality should not be affected.
  • Environmental factors too numerous to mention can affect the maximum distances obtainable at a particular site. Use “maximum distance” figures as a general guideline only .

Model 1040 Distance Table in Miles (km)

Data Rate (bps)Wire Gauge 19 AWG ( 0.9 mm)24 AWG (0.5 mm)26 AWG (0.4 mm) 38,4006.0(9.7)4.5(7.2)2.5(4.0) 19,2009.0(14.5)6.5(10.5)4.0(6.4) 9,60010.0(16.1)7.0(11.3)5.0(8.0) 4,80011.0(17.7)8.0(12.9)6.0(9.7) 1,20012.0(19.3)10.0(16.1)6.0(9.7)
Page 12 of the Patton electronic 1040 user manual — DIRECTION “DCE” STANDARD SETTING DIRECTION
Page 12 · click to enlarge
Page 12

APPENDIX C

APPENDIX D

PATTON MODEL 1040 PIN/SIGNAL ASSIGNMENTS

PATTON MODEL 1040 BLOCK DIAGRAM

Patton electronic 1040 — APPENDIX C diagram (page 12)
Fig. 23

DIRECTION “DCE” STANDARD SETTING DIRECTION

Patton electronic 1040 — DIRECTION “DCE” STANDARD SETTING DIRECTION diagram (page 12)
Fig. 24
Patton electronic 1040 — DIRECTION “DCE” STANDARD SETTING DIRECTION diagram (page 12)
Fig. 25
1. (FG) Frame Ground 2- (TD) Transmit Data To Model 1040 3- (RD) Receive Data From Model 1040 4- (RTS) Request to Send To Model 1040 5- (CTS) Clear to Send From Model 1040 6- (DSR) Data Set Ready From Model 1040 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect From Model 1040 9- +DCV To Model 1040
From Model 1040Transmitting Clock - 15 From Model 1040Receive Clock - 17 To Model 1040Local Analog Loopback - 18 To Model 1040Data Term. Ready (DTR) - 20 To Model 1040Remote Digital Loopback - 21 To Model 1040External Clock - 24 From Model 1040Test Mode - 25

Copyright © 1998 Patton Electronics Company

All Rights Reserved

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 1040

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 1040

Be the first to ask — other owners or our team will answer.