COMSPHERE 3811Plus Modem Installation Instructions Document Number 3980-A2-GZ41-20
This document provides basic installation instructions for the COMSPHERE 3811Plus (Model 3981) modem. For complete configuration and operation instructions, refer to the COMSPHERE 3800Plus Modems User’s Guide (Document Number 3980-A2-GB30).
In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
June 1998

information must be provided to the telephone company.
commission, public service commission, or corporation commission for information.)
9. The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such a message clearly contains, in a margin at the top or bottom of each transmitted page, or on the first page of the transmission, the date and time it is sent, and an identification of the business, or other entity, or other individual sending the message, and the telephone number of such business, or other entity, or individual.
3. The Ringer Equivalence (REN) is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum RENs for the calling area.
In order to program this information, follow the steps outlined in the manual supplied with your fax software.
The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
If the trouble is causing harm to the telephone network, the telephone company may request that you remove the equipment from the network until the problem is resolved.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone line and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

This modem is suitable for connection to BT circuits with signalling at a nominal frequency of 2280 Hz and may be connected to multipoint or point-to-point circuits. The apparatus does not require signalling or otherwise use the frequency range 0–200 Hz.
Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.
No d.c. interaction is intended between the modem and the telephone network.
This apparatus may be directly connected to a speechband circuit or connected to a relevant branch system for speechband circuits.
The Load Number for this equipment is on the label on the modem. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all devices does not exceed 100.
Interconnection circuits between this modem and any other equipment should be such that the equipment continues to comply with the requirements of EN41003 for TNV (Telephone Network Voltage) circuits and EN60950 for SELV (Safety Extra Low Voltage) circuits after making connection between circuits.
The Ringer Equivalence Number (REN) is a customer guide indicating approximately the maximum number of items of apparatus that should be connected simultaneously to the telephone line. The sum of the RENs should not exceed four. This value includes any BT-provided instrument which may be assumed to have a REN of 1 unless marked otherwise. The REN of this modem is 1.

Connection to Leased Lines
If any other apparatus, including cable or wiring, is connected between the apparatus and the point of connection to any speechband circuit, then all that other apparatus shall comply with the following:
This equipment is classified in the 1st Class category. When used in a residential area or in an adjacent area thereto, radio interference may be caused to radios and TV receivers, etc. VCCI-1
(i) apparatus approved for the purpose of connection between the apparatus and a speechband circuit; and
Due to JATE (Japan Approvals Institute for Telecommunications Equipment) regulations, only three attempts to dial a number are permitted in a 3-minute period. If a fourth attempt is made to dial the same number, the modem returns the ERROR return code. This restriction applies to the number dialed from the
(ii) cable or wiring complying with a code of practice for the installation of equipment covered by this part of BS 6328 or such other requirements as may be applicable.
Safety Notice · Ringer Equivalence Number · Restrictions

command line or from a directory. An occurrence of the restriction is canceled when a different number is dialed, or when three minutes have elapsed.
Equipment Warranty and Support
The 3811Plus modem (see Figure 1) is designed for installation in a COMSPHERE 3000 Series Carrier which supplies operating power and the dial-line and/or leased-line network connections. For power, dial-line, leased-line, Network Interface Module (NIM), and network management cabling information, refer to the COMSPHERE 3000 Series Carrier Installation Manual (Document Number 3000-A2-GA31).
Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods:
In addition to the carrier, the following customer-supplied equipment may be required for the installation of a 3811Plus modem:
— Within the U.S.A., call 1-800-870-2221
— From outside the U.S.A., call 727-530-2340
After opening the modem’s package, check for damage and verify that the following items are present:
— 50-pin to modular cable (RJ11C) for dial
— 50-pin to modular cable (JM8) for leased line
Examine the equipment carefully upon arrival. If there is an obvious defect or you experience trouble please contact your sales or service representative (as appropriate) for repair or warranty information. If the product needs to be returned to the company service center for repair, contact them directly for return instructions using one of the following methods:
If the modem is to be managed by a network management system, an SDU must be supplied and properly connected to the network management controller. For proper network management connection to the SDU, refer to the appropriate network management system user’s guide.
— Within the U.S.A., call 1-800-870-2221
— From outside the U.S.A., call 727-530-2340
permissive applications · applications

EIA232/V.24
RS366A/V.25 (3800) EIA232/V.24
RI
SQ
V.35 (3600/3500)
TXD
RXD
RTS
CTS
DSR
DTR
LSD
Figure 1. 3811Plus Modem

The COMSPHERE 3000 Series Carrier has 17 slots which can hold up to 16 modems and one SDU. The SDU is required when the modems in the carrier are controlled by an NMS, or when multiple carriers in a cabinet configuration are to be controlled by a single SDCP. The SDCP of the COMSPHERE 3000 Series Carrier is the user interface to the 3811Plus modem. A single SDCP can control modems in up to eight carriers.

To install a 3811Plus modem into the carrier, perform the following steps.

Slide the modem into the slot, aligning the modem with the rear connector plate, until the backplane connector and DTE connector seat firmly into the back of the carrier. To lock the modem into the carrier, press the faceplate latch until a click is heard.
Loosely fasten the plate. This allows for slight adjustments later when installing the modem.

Always use a ground strap when handling a modem. Always store a 3811Plus modem in an antistatic bag when it is removed from the carrier.
25-Pin DTE Connectors

If an SDCP is installed, verify that the SDCP can be used to control the modem. Perform the following steps.

SDU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
F1 F2 F3 OK Alarm BckUp Test EC
The carrier number selection has a range of 1 to 8. With an SDU installed, a single SDCP can control up to eight carriers.
If the modem fails, or an alarm condition exists, the Alrm LED on the faceplate lights up or flashes. It may be possible to run a diagnostic self-test from the SDCP. See Test Branch in the COMSPHERE 3800Plus Modems User’s Guide.
Return to the rear of the carrier and tighten the rear connector plate.
The Front Panel LED on the modem’s faceplate lights up.
The LCD displays the Top-Level menu for the selected modem.

If you select Sync Leased, a new prompt asks you to select Answer Mode (F1) or Originate Mode (F3). Press the appropriate key.
After the modem passes the power-up self-test, configure it for operation using one of the factory preset configurations.
The 3811Plus modem has several factory preset templates that contain the proper configuration options (straps) for different environments. Modems are shipped from the factory with the Async Dial default configuration options stored in memory. To prepare the modem for Sync Dial, Sync Leased, UNIX Dial, Cellular (Mobile), or Cellular (PSTN), you must change the factory setting, using either the SDCP or the AT command &Fn, as described in the following sections.
The LCD displays Sav EditArea to.
The Cellular (Mobile) and Cellular (PSTN) settings (and the analogous AT commands &F5 and &F6) are available only if Enhanced Throughput Cellular (ETC) is installed.
Press the F1 key to select Active (Saved). The LCD displays Command Complete.
To change a factory template from the Async Dial preset configuration using the SDCP, perform the following steps.
When using AT commands, the following criteria must be met:
Select key again. The Front Panel LED of the selected modem lights up.
F2 F3
The LCD now displays Ld EditArea frm.
The screen displays OK.

To change a factory template using AT commands, perform the following steps.
The menu tree accessible from the SDCP contains the following branches:
Call Setup Used to dial, disconnect, and
answer telephone calls as well as store up to 10 telephone numbers in directory locations.
Status Used to monitor the current
status of the VF line and DTE interface as well as view the identity of the modem.
configurations:
0 is Async Dial 1 is Sync Dial 2 is Sync Leased (Answer Mode) 3 is UNIX Dial 4 is Sync Leased (Originate Mode) 5 is Cellular (Mobile) 6 is Cellular (PSTN)
Test Used to begin and end various
modem tests.
Configure Used to change and save the
modem’s configuration options.
Control Used to control the modem’s
hardware and software functions.
Remote Used to access and control a
remote 3800Plus series modem.
Synchronous factory preset configurations (&F1, &F2, and &F4) inhibit AT command control. To regain AT command control, you must use the SDCP to load a different factory preset configuration.
Security Used to control the modem’s
dial access security. Appears only if the optional security feature is installed.
The AT commands &F5 and &F6 are available only if Enhanced Throughput Cellular (ETC) is installed.
The following pages show the general menu structure of the SDCP displays. The model, installed features, and configuration options all may affect what is actually displayed at each level of the menus.


Displays current status of modem along with data rate and error control mode.
TX RX #
Ser# Mod # FRev HPt# FPt#
LSD DTR DSR Tst TXD RXD RTS CTS
Display Clear No Signal
SigQual RcvLev Sig/Noise NearEcho FarEcho FarEchDel EchoFreqOff
Directory Locations 1 – 10
Does not appear in Remote Mode. (Rem_Digital_Loop, Loc_Digital_Loop, and Pattern appear if the secondary channel is used.)
Some choices within this group may not appear depending upon how previous configuration options have been selected.
Appears only if SDC is installed.
DTE_Interface Async/Sync Mode Async DTE Rate Sync DTE Rate #Data Bits Parity Bit #Stop Bits DTR Action DSR Control RTS Action CTS Control RTS/CTS Delay LSD Control TX Clock Source CT111_Rate Cntl DTE_Rate = VF
DTE_Dialer DTE Dialer Type AT Escape Char Escape GuardTim BreakForceEscap CommandCharEcho CarriageRtn Char Backspace Char Linefeed Char Result Codes ExtendResltCode ResultCode Form V25bis Coding V25bis IdleFill V.25b NewLineChr AT Cmnd Mode DTR Cont Repeat
Line_Dialer AutoAnswerRing# Dialer Type DialTone Detect Blind Dial Paus BusyTone Detect "," Pause Time NoAnswer Timout Fast Disconnect Long Space Disc No Carrier Disc No Data Disc NoDataDiscTrig Auto Make Busy MakeBusyViaDTR DTR Auto Redial MI/MIC Dialing
Dial_Line Modulation Dial Line Rate Automode Autorate Dial TX Level V22b Guard Tone Train Time Asymmetric Rate Proactive Retrain Fall Fwd Delay

Ld EditArea frm:
Active (Saved) Customer1 Customer2
Leased_Line Leased Mode Modulation LeasedLine Rate Autorate Leased TX Level Bad Ln Auto Orig Rate Auto Orig Auto Redial AutoDialStandby CarrierOn Level V.29 TrainOnData Asymmetric Rate Fall Fwd Delay
V42/MNP/Buffer Err Contrl Mode Sync Comp Mode SDC Negotiation SDC Idle Fill SDC BitEncoding SyncDTE CRC SDC Delay Min Sync Flow Cntrl V42bis Compress MNP5 Compress EC Negotiat Bfr EC Fallbck Char Flw Cntl of DTE Flw Cntl of Mdm XON/XOFF Psthru Mdm/Mdm FlowCtl Break Buffr Ctl Send Break Cntl [SDC Options] Tx Buff Disc Delay Rx Buff Disc Delay Max Frame Size Cellular Enhance BfrSizeInBfrMode
Test DTE RL (CT140) DTE LL (CT141) Test Timeout Rcv Remote Loop V54 Address V54 Device Type
Misc StrapsWhenDisc Speaker Control Speaker Volume Access frm Remt RemAccssPasswrd Dir#1_Callback NetMngmtAddress NMS_Call_Msgs NMS DTR Alarm NetworkPosition CellulrRJ11Adpt
Security EntryWait_Time VF_Prompt_Type #DTE_PW_Tries DTE_PW_TermChar DTE_PW_BkSpChar Get_User_ID NMS_Reporting Answer_Secur Originate_Secur
Does not appear if configured for Synchronous mode
Only appears if Sync_Leased factory template is selected.
Some choices within this group may not appear depending upon how previous configuration options have been selected.
Some choices within this group appear only if optional features are installed.

Secondary Prim (data blckd)
(ExitRem appears instead of Remote when
Does not appear in Remote Mode. (Rem_Digital_Loop, Loc_Digital_Loop, and Pattern appear if the secondary channel is used.)
*3980–A2–GZ41–20* Copyright 1998 Paradyne Corporation