350mA/700mA Battery Charging Jumper The 350mA/700mA Jumper allows you to select the

longer, but consumes less power. Charging the battery at

inputs, outputs, readers, and keypads connected to the 2-

Door Expansion Module. The options are explained in the

address (see DIP Switches 1 to 4) and will recognize the

TypeElevator ) and the module does not support

Other modules in the system cannot activate the 2-

Centaur will identify the 2-Door Expansion Module by its

charging current for the backup battery of the 2-Door

Figure 3Setting the A+ and Bjumpers
DIP switches 5 and 6 determine the access to he protected doors during a communication ailure. SwitchSettingDuring a Communication Failure: 5 = off (0) 6 = off (0)“No Card” Access is denied to all cards and doors are locked until communication is restored. 5 = on (1) 6 = off (0)“2 Cards” Access is granted only when 2 cards of a valid format are presented to the reader. 5 = off (0) 6 = on (1)“All Cards” Access is granted when any card with a valid format is presented to the reader. 5 = on (1) 6 = on (1)“Unlock Door” Doors are unlocked until communication is restored.

Place the EOL jumper ON if the 2-Door Expansion Module

is at the beginning (Start Point) or at the end (End Point) of

Access during Communication Failure (5 and 6)

the E-bus Network (see Figure 2). Otherwise, place the

DIP switch 7 determines if OUT5 and OUT6 will

switch 7 placed in the ON position, the outputs on

DIP switches 5 and 6 determine the access to

the reader can pulse to advise users that a

5 = on (1) 6 = on (1) “Unlock Door”

5 = off (0) 6 = off (0) “No Card”

5 = on (1) 6 = off (0) “2 Cards”

5 = off (0) 6 = on (1) “All Cards”

the lock output is De-energized. When Lock #1 or

Lock #2 is activated, power is applied to the

Activation depends on the setting of the DIP switches

the lock output is Energized. When Lock #1 or Lock

Activation depends on the setting of the DIP switches

Energizedpower in normal state; remove power

switches should have the same setting as the Lock

according to the DIP switch settings as shown in

DIP switches 3 and 4 determine the state of

Address 1Address 2Address 3 Doors Keypad/Reader 1 Keypad/Reader 2Door 3 Door 4Door 5 Door 6Door 7 Door 8 Inputs Z1 Z2 Z3 Z4Input 17 Input 18 Input 19 Input 20Input 21 Input 22 Input 23 Input 24Input 25 Input 26 Input 27 Input 28

Assign Address (1 and 2)

Connected to the CT-V900 controller’s expansion bus, the

Communicationexpansion bus (E-Bus), RS-485, Plug

In order for new DIP switch settings to take effect,

PRINTED IN CANADA 07/2004

2-Door Expansion Module (CA-A470-A) supports two readers, two BCD keypads, four zone inputs, 6 outputs

the 2-Door Expansion Module’s power must be

Inputs: 4 standard without ATZ, 1 tamper Outputs: 6 (open collector) Lock Outputs: 2 lock outputs (Form C relays) each: 15A @ 16VDC (resistive)

and Play, 3 modules per CT-V900

low battery restore = 12.2VDC

CAA470A-EI02

low battery cut-off = 8.5VDC

Operating temp.: 5oC to 55oC (41oF to 133oF)

disconnected and then reconnected.

AC Power: 16VAC, 40VA max. Frequency: 50Hz/60Hz Aux. Current: 500mA (max.) Battery: 12VDC, 7Ah low battery = 10.2VDC

Readersconnect 2 per module
Keypadsconnect 2 per module
Paradox Hellas S.A. CAA470A-EI02 — CAA470A-EI02 diagram (page 1)
Fig. 2

780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADA Tel.: (450) 491-7444 Fax: (450) 491-2313

CA-A470-A Specifications:

CA-A470-A

and two locking devices.

www.paradox.ca

Show 5 more labels / short text on this page
2-Door Expansion Module · Instructions · DIP Switches · Specifications · Introduction
Page 2 of the Paradox Hellas S.A. CAA470A-EI02 user manual — OFF = OK
Page 2 · click to enlarge
Page 2
Paradox Hellas S.A. CAA470A-EI02 — OFF = OK diagram (page 2)
Fig. 3
Figure 6Connection drawing of the CA-A470-A

The reader LEDs can be used to verify the reader’s connections and programming. If no flashing occurs when a

card is presented to the reader, the reader may be installed incorrectly. A short flash indicates that the reader is

specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a

operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must

include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect

Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your

or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising

manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to

© 2001-2004 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399,

particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not

Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as

ON = Communication OK (may flicker)

BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller.

Red “TX” LED and green “RX” LED:

Paradox Hellas S.A. CAA470A-EI02 — OFF = OK diagram (page 2)
Fig. 4

correctly installed, but the card is the wrong type or that the reader was incorrectly programmed.

OFF = Communication failure

Centaur is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.

ON = Battery low or disconnected

ON = Communication failure

OFF = Auxiliary power failure

ON = Battery verification in

Green “CHECK BATT” LED:

6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259, 5886632. Canadian and international patents may also apply.

ON = Auxiliary power

Red “BATT TRBL” LED:

OFF = Power failure

Green “AUX” LED:

Red “COMM” LED:

Green “AC” LED:

ON = AC power

Figure 5CA-A470-A indicators

OFF = OK

Green “READER#2 DATA” and “READER#1 DATA” LED:

Short flash = Receiving card read, but the system

from the improper, incorrect or otherwise faulty installation or use of the merchandise sold.

Slow flash = Communication failure

does not recognize the card’s format

Long flash = Receiving card read

OFF = Not receiving card read

(see also “COMM” LED)

Green “LOCK#1” and “LOCK #2” LEDs:

Green “STATUS” LED:

Flash = Module OK

ON = Relay activated.

acceptance of this warranty.

progress (every minute) · Warranty

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Paradox Hellas S.A. CAA470A-EI02

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Paradox Hellas S.A. CAA470A-EI02

Be the first to ask — other owners or our team will answer.

Original document

Paradox Hellas S.A. CAA470A-EI02 manual PDF

2 pages·587 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…