Operating Instructions
Model No. WV-BP140
WV-BP142 WV-BP144
Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
N0301-0 V8QA5750AN Printed in Japan N 19
For U.S.A
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ- ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manu- al, may cause harmful interference to radio com- munications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SER-
VICING TO QUALIFIED SERVICE PERSONNEL.
FCC Caution: To assure continued compliance, (example - use only shielded interface cables when connecting to computer or peripheral devices). Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
The lightning flash with arrowhead symbol, within an equilateral trian- gle, is intended to alert the user to the presence of uninsulated "dan- gerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The serial number of this product may be found on the bottom of the unit. You should note the serial number of this unit in the space provided and retain this instruction as a per- manent record of your purchase to aid identification in the event of theft.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and mainte- nance (servicing) instructions in the literature accompanying the appli- ance.
Model No.
Serial No. SA 1966
To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.

Panasonic’s WV-BP140/BP142/BP144 series intro- duce a new level of high picture quality and high resolution through the use of a 1/3-inch interline transfer CCD image sensor having 510 horizontal
pixels (picture elements). This model offers cut- ting-edge technology for advanced video surveil- lance.

Control (ELC) (2) Back Light Compensation (3) Line-locked Sync or Multiplexed Vertical
Drive (VD2) (only for WV-BP140 and WV- BP144)/Internal Sync or VD2 (only for WV-BP142)

To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) for the DC 12 V or AC 24 V Input Terminal.

q Auto Iris Lens Connector
Supplies power and control signals to an auto iris lens (not supplied).
light such as a spot light is in the back ground. OFF: Normal picture.
w Flange-back Adjusting Ring
This ring adjusts the back-focal distance or picture focus. Rotate this ring clockwise for a C-mount lens or counterclockwise for a CS- mount lens.
set the selector (ELC) to OFF position. To use in ELC mode, make sure to set the selector (ALC) to OFF position.
The camera mounting screw hole is for mounting the camera onto a mounting brack- et. The camera is originally designed to be mounted from the bottom, however, a top- mounting type is also available. To mount from the top, remove the mount adapter from the bottom of the camera by removing two fixing screws. Attach the mount adapter to the top as shown in the diagram, then mount the camera on the mounting bracket. Make sure that two original screws are used when mounting the mount adapter; longer type screws may damage inner components, too shorter type screws may cause the camera drop.
!1 Lens Drive Signal Selector (VIDEO, DC)
Lets you select the mode according to the type of auto iris lens drive signal to be supplied to the lens from the auto iris lens connector. VIDEO: Select this mode if you are using the
auto iris lens that requires a video drive signal. DC: Select this mode if you are using the
auto iris lens that requires a DC drive signal.
!2 Video Output Connector (VIDEO OUT)
This connector is for connecting with the VIDEO IN connector of the video monitor. Whenever the multiplexed vertical drive (VD2) signal is supplied to this connector, the cam- era synchronization mode is automatically set to Vertical Drive.
t Focus Fixing Screw
y Power Cord (only for WV-BP140)
Connect this power cord to an electrical out- let of 120 V AC 60 Hz.
u DC 12 V Input Terminal
[DC 12V IN (only for WV-BP142)] This terminal is for connecting the 12 V DC power supply cord.
i AC 24 V Input Terminal
[AC 24V IN (only for WV-BP144)] This terminal is for connecting the 24 V AC 60Hz power supply cord.
o Automatic Light Control/Electronic Light
Control Selector (ALC, ELC) Lets you select the mode according to the lens type used. ALC: Select this mode when an auto iris lens
(ALC lens) is used with this camera. ELC: Select this mode when a fixed iris lens
or manual iris lens is used with this cam- era.
!0 Back Light Compensation Mode Selector
[BLC ON, OFF (ALC, ELC)] Lets you select BLC ON or OFF according to the position of the object and light conditions on the screen.
e Lens (option) · r Mount Adapter

Installation of Auto Iris Lens Connector
Connect the power cord to an electrical outlet of 120V AC 60Hz.
Install the lens connector (YFE4191J100) when using a video drive ALC lens. The installation should be made by qualified service personnel or system installers. Cut the iris control cable at the edge of the lens connector to remove the existing lens connector and then remove the outer cable cover of the sup- plied connector as shown in the diagram. The pin assignment of the lens connector is as fol- lows:
Connect the power cord to the DC 12V IN ter- minal on the rear panel of the WV-BP142.

Pin 1: Power source; +9 V DC, 50 mA max. Pin 2: Not used Pin 3: Video signal; 1.3 V[p-p]/40 kΩ Pin 4: Shield, ground

Solder the lens cable to the pins of the sup- plied connector.
10.5V DC ≤VA −(R x 0.42 x L) ≤16 V DC
Before you mount the lens, loosen the screw on the side of the camera, and rotate the flange-back adjusting ring clockwise until it stops. If the ring is not at the end, the inner lens or CCD image sensor may be damaged. q Mount the lens by turning it clockwise on the
VA −12 L standard = (meters) 0.42 x R VA −16 L minimum = (meters) 0.42 x R VA −10.5 L maximum = (meters) 0.42 x R
lens mount of the camera. w Connect the lens cable to the auto iris lens
connector on the side of the camera.

Connect the power cable to the AC 24V IN terminal on the rear panel of the WV-BP144.

24 V AC, 60 Hz (19.5 V - 28 V)

The lens mount should be a C-mount or CS-mount (1”-32UN) and the lens weight should be less than 450 g (0.99 lbs). If the lens is heavier, both the lens and camera should be secured by using the supporter. The protrusion at the rear of the lens should be as shown in the diagram.
To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) for the DC 12 V or AC 24 V Input Terminal.

The following adjustment should be made by qualified service personnel or system installers.
q Loosen the screw on the side of the camera.
do not rotate the ring counterclockwise by force after it stops. If the ring is rotat- ed by force, the inner lens or CCD image sensor may be damaged.
e Tighten the screw on the side of the camera.
cause damage to the screw or deviation of focus.

Pick-up Device: 510 (H) x 492 (V) pixels, Interline Transfer CCD Scanning Area: 4.8 (H) x 3.6 (V) mm (Equivalent to scanning area of 1/3” pick-up tube) Synchronization: WV-BP140 and WV-BP144: Line-locked or Multiplexed Vertical Drive (VD2), selectable WV-BP142: Internal or Multiplexed Vertical Drive (VD2), selectable Scanning System: 2 : 1 interlace Scanning: 525 lines / 60 fields / 30 frames Horizontal: 15.75 kHz Vertical: 60.00 Hz Horizontal Resolution: 380 lines Video Output: 1.0 V[p-p] NTSC composite 75 Ω/ BNC connector Signal-to-Noise Ratio: 46 dB (Equivalent to AGC Off, weight On) Electronic Light Control: Equivalent to continuous variable shutter speed between 1/60 s and 1/120 000 s Lens Drive: DC or Video, selectable Minimum Illumination: 0.08 lx (0.008 foot-candle) at F1.4 Lens Mount: C-mount or CS-mount, selectable Ambient Operating Temperature: −10°C - +50°C (14°F - 122°F) Ambient Operating Humidity: Less than 90 % Power Source and WV-BP140: 120 V AC 60 Hz, 2.3 W Power Consumption: WV-BP142: 12 V DC, 175 mA WV-BP144: 24 V AC 60 Hz, 2.1 W Dimensions (without lens): 67 mm (W) x 65 mm (H) x 123 mm (D) 2-5/8” (W) x 2-9/16” (H) x 4-13/16” (D) Weights (without lens): WV-BP140: 0.45 kg (0.99 lbs) WV-BP142: 0.3 kg (0.66 lbs) WV-BP144: 0.32 kg (0.71 lbs)
Weights and dimensions indicated are approximate. Specifications are subject to change without notice.
Body Cap 1 pc. ALC Lens Connector (YFE4191J100) 1 pc.
Lenses: WV-LA2R8C3B, WV-LA4R5C3B, WV-LA9C3B, WV-LA210C3, WV-LA408C3, WV-LA908C3, WV-LZ61/10, WV-LZ62/2, WV-LZ62/8, WV-LF4R5C3A, WV-LF9C3A, WV-LFY3C3, WV-LFY45C3, WV-LFY9C3
Panasonic Security and Digital Imaging Company A Division of Matsushita Electric Corporation of America
Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838
Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840
Panasonic Canada Inc. 5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905)624-5010
Panasonic Sales Company Division of Matsushita Electric of Puerto Rico Inc. Ave. 65 de Infanteria. Km. 9.5 San Gabriel Industrial Park, Carolina, Puerto Rico 00985 (809)750-4300
2001 © Matsushita Communication Industrial Co., Ltd. All rights reserved
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.