“ZNR” Transient/Surge Absorbers, Type E “ZNR” Transient/Surge Absorbers, Type CK, SC
Precautions for Handling
1. Precautions for Safety The “ZNR” Transient/Surge Absorbers (hereafter referred to as “The ZNR Varistors”) may fail in a short-circuit mode or in an open-circuit mode, when subjected to severe conditions of electrical, environmental and/or me chanical stresses beyond their specifi ed “Ratings” and specifi ed “Conditions”, resulting in burnout, fl aming or glowing in the worst case. Following “ Precautions for Safety” and “Application Notes” shall be taken in your major consideration. If you have a question about the “Precautions for Handling”, please contact our engineering section or factory.
1.1.3 When the ZNR Varistors are applied to between a live part and a metallic chassis of equipment, following safety countermeasures shall be taken to protect human from electric shock. A) The metallic chassis shall be earthed to the
ground. B) The live part shall be equipped with a protective
cover for preventing electric shock.
Thermal. Fuse
✽Fuses shall use rated voltages appropriate for circuits. ✽Finally, confi rm that the secondary disaster does not
occur even if the ZNR mounted on equipment breaks. ✽Set a thermal fuse to get high thermal conductivity
with ZNR.
series to the Varistor to be protected. (See Table 1) B) Use current type fuses and a thermal type fuse
which are thermally coupled each others. (See Table 1)
Apr. 2008 00
“ZNR” Transient/Surge Absorbers · Current Fuse

2.2 Circuit Design 1 (Selection of Varistor Voltage Rating) 2.2.1 General Precautions In selection of Varistor Voltage Ratings for line protection, following general precautions shall be taken in your consideration; (1) Maximum operating voltage shall be lower than
2.4 Environmental Conditions (1)The ZNR Varistors shall not be exposed
outdoors, because of being designed for in doors
use. (2)The ZNR Varistors shall not be operated beyond
the Specifi ed Operating Temperature Range and shall not be exposed to direct sunlight and heating part of equipment. (3)The ZNR Varistors shall not be operated under
the specifi ed “Maximum Allowable Voltage” of the Varistor applied. (2) Some reasonable margin is required against
se vere conditions of high temperatures and high humidities such as places exposed to rain, wind and vapor. (4)The ZNR Varistors shall be free from dust, salty
fl uctuation of the primary AC line Voltage where the Varis tor is applied for preventing mechanical and/or electrical failures of the device.
wind and atomospheres polluted by corrosive gas.
2.2.2 Across-the-Line Use (Line to Line surge protection)
2.5 Precautions for Assemblies and Handlings 2.5.1 Solvent Cleaning Organic solvents such as thinner and acetone etc. shall not be applied to the ZNR Varistors for preventing deterioration of the external coating or molding resin. 2.5.2 Abnormal Mechanical Stresses Abnormal mechanical stresses beyond the spec i fi ed values such as strong falling shocks, ribrations and bending/pulling forces, shall be kept minimum to preventmechanical/electrical failures of the devices. 2.5.3 Plastic Molding If another plastic molding is applied to the ZNR Varistors on your option, the infl uences on reliability of the ZNR Varistors shall be carefully investigated in your equipment. 2.6 Long Term Storage (1)The ZNR Varistors shall not be stored under
rises due to load unbalance of separately wired loads, short circuit between the live line and the nutral line or LC resonance at switching for a capacitive load, ZNR Varistors with ✽ are recommended for AC120 V or 240 V applications. (See Table 1)
2.2.3 Line to Ground Use (Line to Ground Surge pro tec tion)
circuits employing ZNR Varistor is conducted, the ZNR Varistor shall be removed after getting approv al from the customer, or the ZNR Varistor ✽ ✽ with the Maximum Allowable Voltage ex ceeding to the test voltage shall be applied. (See Table 1) When AC1000 V or 1200 V dielectric with
severe conditions of high temperatures and high humidities. Store them indoors under 40 °C max. and 75 %RH max. Use them within one year, if stored beyond the limit, check the solderbility before use. (2)The ZNR Varistors shall not be stored under
standing test is conducted, ZNR Varistors shall be removed after getting approval from the customer according to the relevant regulations, or ZNR Varistor ✽ ✽ ✽ with the Maximum Allowable Volt age exceeding to the test voltage shall be applied. (See Table 1)
corrosive atomospheres such as hydrogen sulfi de, sulfurous acid, chlorine and ammonia. (3)The ZNR Varistors shall not be exposed to direct
2.3 Circuit Design 2 (Fusing Varistors) 2.3.1 When a line current of equipment is higher than the recommended current rating of the fuse in Table 2, the location of the fuse shall be arranged according to Fig 2.
sunlight and shall not be stored under dew formation.
2.7 Regarding to “Safety Regulations of the Varistors”
In case of applications to UL and CSA standards, refer to “Application Notes for UL and CSA Recognized” ZNR “Varistors”
2.8 Parallel Capacitances of the ZNR Varistors The ZNR Varistors have relatively high capacitances specifi ed in the individual specifi cations, special consideration shall be taken into account in applications to high frequency transmission lines or circuits.
Fig. 2 Alternative Fuse Location/placement
for Varis tor Pro tec tion
Apr. 2008 00
Fuse · Protected Equipment · ZNR Varistor

Table 1. Application Examples
Across-the-Line/Line to Line Protection Line to Line and Line to Ground Protection
D.C. A.C. Single phase
D.C. A.C. Single phase
Thermal. Fuse Thermal coupling
A.C. 3 phase A.C. 3 phase
Thermal. Fuse
Across the Line Use/Line to Line Line to Ground Use
Part Number of ZNR ZNR
Part Number of ZNR Type E, CK, SC Type E, CK, SC
AC 100 V
471 511 821 ✽✽ AC 120 V 241 271 ✽
AC 100 V to AC 220 V ERZCEK ERZCCK ERZVS34C
ZNR1 ZNR3
ZNR2 ZNR4
AC 200 V to AC 220 V 471 AC 240 V 511 821 ✽✽ AC 240 V 511
Apr. 2008 00