Page 1 of the Panasonic TYPE E user manual — – EC129 –
Page 1 · click to enlarge
Page 1

“ZNR” Transient/Surge Absorbors, Type E, Type CK, SC

“ZNR” Transient/Surge Absorbers, Type E “ZNR” Transient/Surge Absorbers, Type CK, SC

Precautions for Handling

1. Precautions for Safety The “ZNR” Transient/Surge Absorbers (hereafter referred to as “The ZNR Varistors”) may fail in a short-circuit mode or in an open-circuit mode, when subjected to severe conditions of electrical, environmental and/or me chanical stresses beyond their specifi ed “Ratings” and specifi ed “Conditions”, resulting in burnout, fl aming or glowing in the worst case. Following “ Precautions for Safety” and “Application Notes” shall be taken in your major consideration. If you have a question about the “Precautions for Handling”, please contact our engineering section or factory.

  • 1.1 Operating Conditions 1.1.1 The ZNR Varistors shall not be operated beyond the specified “Ratings” and “Environmental Conditions” in the Catalog or the Specifi cations to prevent them from deterioration, breakdown, fl aming or glowing.
  • The ZNR Varistors shall not be operated exceeding the specifi ed “Maximum Allowable Voltage” in the Catalog or the Specifi cation.
  • The ZNR Varistors shall not be subjected to energy levels above their specifi ed “Maximum Energy Ratings” in the Catalog or the Specifi cations.
  • In case of application to repeated surge/ overvoltages, the ZNR Varistors shall not be subjected to surge currents and energy levels above the specifi ed maximum ratings in “Impulse Life Rating” in the Catalog or the Specifi cations.
  • When surge/overvoltages are intermittently applied to the ZNR Varistors with short durations, the devices shall not be operated beyond the specifi ed “Rated Power” in the Catalog or the Specifi cations.
  • The ZNR Varistors shall not be operated beyond the specifi ed “Operating Temperature Range” in the Catalog or the Specifi cations.
  • It is recommended that the ZNR Varistors, if not fused, shall be located away from other combustible components. 1.1.2 The ZNR Varistor shall be operated correctly under following conditions to prevent Varistors from causing mechanical damages and ruptures and to protect human from serious injuries;
  • The ZNR Varistors shall not be operated exceeding the specifi ed “Maximum Allowable Voltage Ratings” in the Catalog.
  • The ZNR Varistors shall not be operated beyond the “Maximum Peak Current Ratings” in the Catalog.
  • Some safety countermeasure such as a protective case covering the Varistor is recommended, if necessary.

1.1.3 When the ZNR Varistors are applied to between a live part and a metallic chassis of equipment, following safety countermeasures shall be taken to protect human from electric shock. A) The metallic chassis shall be earthed to the

ground. B) The live part shall be equipped with a protective

cover for preventing electric shock.

  • Recommendation fuse
ERZC20EKERZC32KERZVS34C ERZC40CK 10 A max.20 A max.20 A max. 100 to 120 °C 5 A100 to 120 °C 10 A100 to 120 °C 10 A

Thermal. Fuse

✽Fuses shall use rated voltages appropriate for circuits. ✽Finally, confi rm that the secondary disaster does not

occur even if the ZNR mounted on equipment breaks. ✽Set a thermal fuse to get high thermal conductivity

with ZNR.

2. Application Notes

  • 2.1 Protective Devices for Varistors 2.1.1 The ZNR Varistors shall be protected from serious accidents due to unexpected physical phenomenor by following safety countermeasures.
  • In case of “Across-the Line Use”, the ZNR Varistors shall be protected by connecting a ground fault circuit interrupter of fusing in series to the devices. (See Table 1)
  • In case of “Line to Ground Use”, the short-circuit of the Varistor may not blow the current type fuse due to the grounding resistance (between Line and Ground), which may cause fl aming or burnout of the devices in the worst case. Following safety countermeasures (A or B) are recommended; A) Connecting a “leakage current circuit breaker” in

series to the Varistor to be protected. (See Table 1) B) Use current type fuses and a thermal type fuse

which are thermally coupled each others. (See Table 1)

Apr. 2008 00

– EC129 –

“ZNR” Transient/Surge Absorbers · Current Fuse

Page 2 of the Panasonic TYPE E user manual — – EC130 –
Page 2 · click to enlarge
Page 2

“ZNR” Transient/Surge Absorbors, Type E, Type CK, SC

2.2 Circuit Design 1 (Selection of Varistor Voltage Rating) 2.2.1 General Precautions In selection of Varistor Voltage Ratings for line protection, following general precautions shall be taken in your consideration; (1) Maximum operating voltage shall be lower than

2.4 Environmental Conditions (1)The ZNR Varistors shall not be exposed

outdoors, because of being designed for in doors

use. (2)The ZNR Varistors shall not be operated beyond

the Specifi ed Operating Temperature Range and shall not be exposed to direct sunlight and heating part of equipment. (3)The ZNR Varistors shall not be operated under

the specifi ed “Maximum Allowable Voltage” of the Varistor applied. (2) Some reasonable margin is required against

se vere conditions of high temperatures and high humidities such as places exposed to rain, wind and vapor. (4)The ZNR Varistors shall be free from dust, salty

fl uctuation of the primary AC line Voltage where the Varis tor is applied for preventing mechanical and/or electrical failures of the device.

wind and atomospheres polluted by corrosive gas.

2.2.2 Across-the-Line Use (Line to Line surge protection)

  • Select the ZNR Varistors recommended in Table 1. Notes: Because the primary line voltage temporarily

2.5 Precautions for Assemblies and Handlings 2.5.1 Solvent Cleaning Organic solvents such as thinner and acetone etc. shall not be applied to the ZNR Varistors for preventing deterioration of the external coating or molding resin. 2.5.2 Abnormal Mechanical Stresses Abnormal mechanical stresses beyond the spec i fi ed values such as strong falling shocks, ribrations and bending/pulling forces, shall be kept minimum to preventmechanical/electrical failures of the devices. 2.5.3 Plastic Molding If another plastic molding is applied to the ZNR Varistors on your option, the infl uences on reliability of the ZNR Varistors shall be carefully investigated in your equipment. 2.6 Long Term Storage (1)The ZNR Varistors shall not be stored under

rises due to load unbalance of separately wired loads, short circuit between the live line and the nutral line or LC resonance at switching for a capacitive load, ZNR Varistors with ✽ are recommended for AC120 V or 240 V applications. (See Table 1)

2.2.3 Line to Ground Use (Line to Ground Surge pro tec tion)

  • Select the ZNR Varistors recommended in Table 1. Notes: When 500 V insulation resistance test of the

circuits employing ZNR Varistor is conducted, the ZNR Varistor shall be removed after getting approv al from the customer, or the ZNR Varistor ✽ ✽ with the Maximum Allowable Voltage ex ceeding to the test voltage shall be applied. (See Table 1) When AC1000 V or 1200 V dielectric with

severe conditions of high temperatures and high humidities. Store them indoors under 40 °C max. and 75 %RH max. Use them within one year, if stored beyond the limit, check the solderbility before use. (2)The ZNR Varistors shall not be stored under

standing test is conducted, ZNR Varistors shall be removed after getting approval from the customer according to the relevant regulations, or ZNR Varistor ✽ ✽ ✽ with the Maximum Allowable Volt age exceeding to the test voltage shall be applied. (See Table 1)

corrosive atomospheres such as hydrogen sulfi de, sulfurous acid, chlorine and ammonia. (3)The ZNR Varistors shall not be exposed to direct

2.3 Circuit Design 2 (Fusing Varistors) 2.3.1 When a line current of equipment is higher than the recommended current rating of the fuse in Table 2, the location of the fuse shall be arranged according to Fig 2.

sunlight and shall not be stored under dew formation.

2.7 Regarding to “Safety Regulations of the Varistors”

In case of applications to UL and CSA standards, refer to “Application Notes for UL and CSA Recognized” ZNR “Varistors”

2.8 Parallel Capacitances of the ZNR Varistors The ZNR Varistors have relatively high capacitances specifi ed in the individual specifi cations, special consideration shall be taken into account in applications to high frequency transmission lines or circuits.

Fig. 2 Alternative Fuse Location/placement

for Varis tor Pro tec tion

Apr. 2008 00

– EC130 –

Fuse · Protected Equipment · ZNR Varistor

Page 3 of the Panasonic TYPE E user manual — – EC131 –
Page 3 · click to enlarge
Page 3

“ZNR” Transient/Surge Absorbors, Type E, Type CK, SC

Table 1. Application Examples

Across-the-Line/Line to Line Protection Line to Line and Line to Ground Protection

D.C. A.C. Single phase

D.C. A.C. Single phase

ZNR2

Thermal. Fuse Thermal coupling

ffuse
ffuse

A.C. 3 phase A.C. 3 phase

ZNR4

Thermal. Fuse

ffuse
ffuse

Across the Line Use/Line to Line Line to Ground Use

Part Number of ZNR ZNR

Part Number of ZNR Type E, CK, SC Type E, CK, SC

ZNR

AC 100 V

471 511 821 ✽✽ AC 120 V 241 271 ✽

AC 100 V to AC 220 V ERZCEK ERZCCK ERZVS34C

ERZC EK ERZC CK ERZVS34C

ZNR1 ZNR3

ZNR2 ZNR4

AC 200 V to AC 220 V 471 AC 240 V 511 821 ✽✽ AC 240 V 511

Apr. 2008 00

– EC131 –

Show 21 more labels / short text on this page
f · f ZNR1 · ZNR1 Protected · Protected · Equipment · Equipment · Con nec tions · “ZNR” Transient/Surge Absorbers · f ZNR3 · f ZNR3 · f · Protected · Equipment · Protected · f · Equipment · Thermal coupling · Nominal Line Voltage · Nominal Line Voltage · Selection Examples · 201 241 271

Ask about the Panasonic TYPE E

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panasonic TYPE E

Be the first to ask — other owners or our team will answer.

Original document

Panasonic TYPE E manual PDF

3 pages·118 KB·Battery·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…