General Information

Overview

The APC® by Schneider Electric J Type Power Conditioner protects audio-video systems from power spikes and surges. The J Type has noise filter banks, which reduce electromagnetic interference to ensure the best picture and sound quality. The unit also provides clean and safe power to connected equipment in the event of a power outage. Inventory

Safety

Electrical Hazard: For indoor use only.

  • Risk of electric shock. Do not plug into another relocatable power tap.
  • Overloading. Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure the total load to this device does not exceed that which is listed in the Specifications section of this manual.
  • Power . Ensure this device is connected to a properly grounded AC power source. Further ensure the device is plugged into a source providing the required 120 Vac. Do not use a plug adapter which defeats the ground pin of the AC plug.
  • Placement . Do not install this device on any unsteady surface. Do not install this device on any heat source.
  • Water and Moisture . Do not use this product near any source of water, or in an environment where the relative humidity may exceed 95% (non-condensing)
  • Polarization . This device has a polarized AC line plug having one grounding pin. This plug will only fit into the wall outlet in one orientation. This is a safety feature. Do not remove the round grounding pin.
  • System Ground Terminal . The unit provides for the connection of grounding wires from all of your equipment to a central terminal lug. This ground connection eliminates ground loop problems; tie all component grounds to this screw to break any possible ground loops that can cause an audible noise.
  • Servicing . There are no user-serviceable components within this device. Removal of the rear cover of this device may present a shock hazard, and/or void the warranty.
  • Damage Requiring Service . If any type of damage occurs to this device, immediately disconnect it from the wall outlet. Notify APC Technical Support or Customer Service at once.

(1) (1) (1) · (1) (1)

Page 6 of the APC AV Power Filter (J25B) user manual — Rear view
Page 6 · click to enlarge
Page 6

Components

Front view

SETUP button - Push to scroll through the Setup menu screens. Press and hold for three seconds to save the current

screen as the default screen.

STATUS button - Push to scroll through the menu screens. Press and hold for 10 seconds to view the Diagnostic

menu screens.

ON/OFF button - Push this button to apply power to the outlets. Note that the unit will continue to provide surge

protection, even if it is off.

UP/DOWN buttons - Use the up and down buttons to scroll through options on the menu screens.

Removable front bezel - The front bezel can be removed to connect the battery, or to replace the battery.

Rear view

Coaxial surge-protected, input and output jacks

Battery backup outlets with surge protection and noise filtering; voltage regulation is available on the J35B model

Surge-protected outlets with noise filtering

Circuit breaker reset button

120V input outlet, use with the supplied input power cord

Building wiring fault indicator (See “Troubleshooting” on page 9.)

TVSS ground screw. Use a wire to connect any ungrounded component to this screw. Connecting to the TVSS

screw will prevent sound or video interference from ungrounded equipment.

Telephone line surge-protected, input and output jacks

USB port for use with optional PowerChute Personal Edition software, available as a free download at

www.apc.com In the event of a power outage, this software will save files and gracefully shut down the computer. Use the supplied USB cable to connect the UPS to the home computer.

Controlled by Master outlet (J35B only)

Controlled by Master outlets (J35B only)

Master outlet (J35B only)

av022a · LCD Display

Page 7 of the APC AV Power Filter (J25B) user manual — Installation
Page 7 · click to enlarge
Page 7

Installation

Connect the Battery

Connect Input Power

Use the input power cord to connect the unit to input power. If the unit is functioning properly, the display will illuminate. Connect the other end to a grounded, 120 V receptacle.

Show 7 more labels / short text on this page
av023a · av025a · av025a · bu059a · av026a · av027a · av028a
Page 8 of the APC AV Power Filter (J25B) user manual — Power-saving Master and Controlled outlets (J35 units only)
Page 8 · click to enlarge
Page 8

Connect the Equipment

Battery backup and surge outlets

Connect equipment to the outlets on the rear panel of the unit.

  • Battery backup outlets—connect equipment that requires power during a power outage to these outlets, such as a computer or DVR.
  • Surge Protection only outlets—connect noncritical equipment to these outlets, as these outlets will not have power during a power outage. The outlets continue to provide surge protection, even if the unit if OFF.

Power-saving Master and Controlled outlets (J35 units only)

When the power-saving feature is enabled, the J35B reduces power consumption by automatically disconnecting utility power to devices that are not in use.

When the device connected to the Master outlet goes into sleep or standby mode, the J35B will disconnect power to components connected to the Controlled by Master outlets, conserving energy.

For example, if a desktop computer is connected to the Master outlet, when it goes into sleep mode, the J35B will disconnect power peripheral devices connected to the Controlled by Master outlets, such as a monitor, printer, and speakers.

1. Before connecting components to the unit, determine which components will utilize the Master and Controlled outlets.

– Connect a master device such as a TV to the Master outlet.

– Connect peripheral devices such as amplifiers, DVD players, or sub-woofers to the Controlled

outlets.

2. Connect components to the outlets on the back panel of the unit.
Page 9 of the APC AV Power Filter (J25B) user manual — SOURCE: UTILITY EST RUN T: 4MIN
Page 9 · click to enlarge
Page 9

Operation

Display Interface Menus

Start up menu screens

At initial start up, the LCD screen will scroll through several menu screens and perform a self test.

APC - Legendary Reliability

J35 PWR CONDITNR WITH BATT BACKUP

SELF TEST ON.... ON-LINE TEST

SELF TEST ON.... ON-BATTERY TEST

SELF TEST RSLT: TEST HAS PASSED

Status menu

The Status menu shows the overall status of the unit and of each outlet on the unit. Push the STATUS button to move to the next screen. Use the arrow keys to scroll up and down.

Source of output power and estimated available run time on battery.

SOURCE: UTILITY EST RUN T: 4MIN

The possible Source options include:

  • Utility— Input power is safe and steady
  • Battery— Utility input power is not available or is at an unsafe level, the unit is supplying power from the batteries
  • Vac Boost— Utility input power is too low, the unit is increasing power to a safe level (J35B units only)
  • Vac Trim— Utility input power is too high, the unit is decreasing power to a safe level (J35B units only)
Page 10 of the APC AV Power Filter (J25B) user manual — WEB:WWW.APC.COM/ SUPPORT
Page 10 · click to enlarge
Page 10

Estimate run time and current battery charge. As the battery charge increases, the battery run time will also increase.

EST RUN T: 4 MIN 50%

System load. The system load indicates how much power is being used by the connect equipment. The percentage indicates the amount of the unit capacity currently being used.

SYS LOAD: 900W 90%

Input and output voltage.

INPUT VOLT: 120V OUTPUT VOLT: 120V

INPUT Hz60Hz OUTPUT Hz: 60Hz

Model number and firmware.

MDL#: J35B AV UPS FW VER: 874.P0.D

Serial number.

SN#: JB02008004444

Service contact information.

SERVICE TEL#: 1-888-882-7228

Web support information.

WEB:WWW.APC.COM/ SUPPORT

Setup menu

Use the Setup menus to configure the unit. There are nine setup menus. Push the SETUP button to move to the next screen. Use the arrow keys to scroll up and down.

Page 11 of the APC AV Power Filter (J25B) user manual — LOWBATTWARN: 2MIN PRESS TO CHNG
Page 11 · click to enlarge
Page 11

Audio alarm. Change the alarm setting to on or off. The unit will emit an audible beep if there is a fault or if the unit changes to operate on battery, has a low battery condition, or is overloaded.

AUDIO ALARM: OFF PRESS TO CHNG

Sensitivity. Select Low, Medium, or High to determine how often the until will switch to battery power. If the sensitivity it set to Low, the unit will tolerate more fluctuations in power, and will switch to battery less often. If the sensitivity is set to High, the unit will switch to battery power more often.

SENSITIVITY: MED PRESS TO CHNG

Display dimmer. Change the brightness of the LCD display. Select Off for the display to completely darken when not in use. Push any button on the unit to illuminate the display.

DISPLAY DIM: ON PRESS TO CHNG

Voltage transfer point. Set the value of the input utility voltage at which the unit will switch to battery power.

TO BAT IF < 88V PRESS TO CHNG

Green function. Enable or disable the power-saving Master and Controlled outlets. See “Power-saving Master and Controlled outlets (J35 units only)” on page 4.

GREEN FUNC: ON PRESS TO CHNG

Green function - transfer threshold. Configure the master outlet to recognize when the master device has gone into sleep or standby mode. Configure the delay between when the Master unit turns off and the peripheral units turn off.

APC AV Power Filter (J25B) — GREEN FUNC: ON PRESS TO CHNG diagram (page 11)
Fig. 2

Low battery warning. Set the time at which the unit will provide an audible warning that it almost exhausted battery power.

LOWBATTWARN: 2MIN PRESS TO CHNG

Page 12 of the APC AV Power Filter (J25B) user manual — RESET->DEFLT: NO PRESS TO CHNG
Page 12 · click to enlarge
Page 12

Suggested battery replacement date. The Repdate shows the date on which the battery was last replaced. Update this date if a new battery pack is installed.

REPDATE: 3/04/12 PRESS TO CHNG

Self-test. Select yes to initiate a self-test of the unit. If the test fails, contact APC technical support.

DO SELFTEST: NO PRESS TO CHNG

Runtime calibration. Perform a runtime calibration test to completely discharge the batteries, and recharge them. This allows the unit to accurately predict runtime capacity. This test should be run once a year, after the unit has been in service for at least one year.

RUNTIME CAL: NO PRESS TO CHNG

LED and audible alarms test. Perform this test to test the LEDs and the audible alarms on the unit.

DSPLY-BP TEST: NO PRESS TO CHNG

Screen saver. Turn the screen saver on or off.

SCREEN SAVER: ON PRESS TO CHNG

Reset to factory defaults. Reset all settings to the factory default.

RESET->DEFLT: NO PRESS TO CHNG

Page 13 of the APC AV Power Filter (J25B) user manual — Problem Possible Cause Corrective Action
Page 13 · click to enlarge
Page 13

Troubleshooting

Problem Possible Cause Corrective Action

The unit will not switch on. The unit is not connected to utility power. Ensure that the unit is securely connected to an AC outlet. The internal battery is not connected. Connect the battery. The unit does not provide power during a utility power outage.

Disconnect equipment from the SURGE ONLY outlet and re-connect to a Battery Backup outlet. The unit is operating on battery power, while connected to utility power.

Ensure that essential equipment is not plugged into a SURGE ONLY outlet.

The plug has partially pulled out of the wall outlet, the wall outlet is no longer receiving utility power, or the circuit breaker has been tripped.

Ensure that the plug is fully inserted into the wall outlet. Ensure that the wall outlet is receiving utility power by checking it with another device. The unit is performing an automatic self test.

No action is necessary.

The utility input voltage is out of range, the frequency is out of range, or the waveform is distorted.

Adjust the transfer voltage and sensitivity range.

The circuit breaker has been tripped. Disconnect non-essential equipment from the unit. Reset the circuit breaker. Re- connect equipment one item at a time. If the circuit breaker is tripped again, disconnect the device that caused the trip. The unit does not provide the expected amount of backup time.

Battery Backup outlets may be fully or improperly loaded.

Disconnect non-essential equipment from the Battery Backup outlets and connect the equipment to SURGE ONLY outlets. The battery was recently discharged due to a power outage and has not fully recharged.

Charge the battery cartridge for 16 hours.

The battery has reached the end of its useful life.

Replace the battery.

Power is not supplied to some outlets.

Confirm that the correct peripherals are connected to Controlled outlets. If this feature is not desired, disable the Power- Saving Master and Controlled outlets. The Controlled outlets are not supplying power, even though the Master device is not in sleep mode.

Power to the Controlled outlets has intentionally been turned off.

The Master Outlet threshold may be incorrectly set.

Adjust the threshold when the Master outlet signals the Controlled outlets to shut down.

Page 14 of the APC AV Power Filter (J25B) user manual — Warranty
Page 14 · click to enlarge
Page 14

Specifications

Input/Output J25B J35B

Nominal Voltage 120 V 120 V Input/Output Current 12 A 12 A Frequency 47 - 63 Hz 47 - 63 Hz Number of Outlet Receptacles 8 (6 battery backup, 2 surge only) 8 (6 battery backup, 2 surge only) Dimensions (H x W x L) 9.76 cm x 43.18 cm x 40.64 cm (3.84 in x 17 in x 16 in)

9.76 cm x 43.18 cm x 40.64 cm (3.84 in x 17 in x 16 in) Power Cord 2.43 m (8 ft.) right angle NEMA 5-15 plug 2.43 m (8 ft.) right angle NEMA 5- 15 plug Environmental Performance Specifications

Operating temperature 0º – 40ºC (32º – 104ºF) 0º – 40ºC (32º – 104ºF) Storage temperature -15º – 45ºC (5º – 113º F) -15º – 45ºC (5º – 113º F) Net weight Relative Humidity 0–95% non-condensing 0–95% non-condensing Contact Information

www.apcav.com or 1-888-88APCAV

Replacement Battery

The battery cartridge typically lasts 3 to 6 years, a shorter period if subjected to frequent outages or elevated temperatures. For the J25B, order APCRBC130. For the J35B, order APCRBC131. Please recycle spent battery cartridges.

Contact APC APV Technical Support

For technical support, go to www.apcav.com or call 1-888-88APCAV (1-888-882-7228).

Warranty

The standard warranty is three (3) years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement unit to the customer.

Page 15 of the APC AV Power Filter (J25B) user manual — Specifications
Page 15 · click to enlarge
Page 15
Page 15 of the APC AV Power Filter (J25B) user manual — Specifications
Page 16 of the APC AV Power Filter (J25B) user manual — Specifications
Page 16 · click to enlarge
Page 16
Page 16 of the APC AV Power Filter (J25B) user manual — Specifications
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the APC AV Power Filter (J25B)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the APC AV Power Filter (J25B)

Be the first to ask — other owners or our team will answer.

Original document

APC AV Power Filter (J25B) manual PDF

41 pages·635 KB·Battery·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…