
Manufactured by:

for Before attempting to connect or operate this product, please read these instructions completely.
5. Hand place the top mount bracket and camera into the unit. Check the angle of the camera, remove the bracket/camera and make any necessary adjustments. Once you have achieved the desired camera angle, reattach the top bracket and camera to the housing. Fine focusing can be achieved by manually rotating the lens. 6. Fine focusing (see diagram below): Fixed Lens: Manually rotate the lens until a clear picture is achieved. Vari-Focal Lens: First, adjust the Magnification Lock Screw to the desired magnification (telephoto to wide angle). Tighten the Lock Screw. Next, adjust the Focus Lock Screw until a clear picture is achieved. Tighten the Lock Screw.
Remove equipment from box, contents include:
(1) Cover plate with window (2) Allen wrench security head tool (2) Stainless steel 6-32x1/2" captive Security head screws
(1) Camera mount bracket (1) Camera mount arm (1) Bottom mount bracket (2) 4-40 x 1/4" screws (2) Star washers (2) 2-56 x 3/16" Screws (1) Camera, lens, and PC Board
1. Locate the area on the wall where the housing will be installed and cut a 2 1/4" x 3 3/4" hole into the wall. 2. Run the necessary wiring/cables to this cutout and pull wiring/cables through opening. 3. Using the security tool, loosen the 2 security head screws on the cover plate and remove it. 4. Feed the wiring/cables through one or more of the cable entry holes in the back of the flush mount box. 5. Install the housing into the cutout in the wall and tighten the Phillips head screws on the front of the box. This will pull the lock tabs forward to secure the box to the wall.
Fixed Lens Camera PCF3
Lock Tab Top Mount Bracket
Vari-focal Lens Camera PCV3

Dimensions for the PCF3/PCV3 (not to scale)
PCF1 PCF6W PCF6 PCF5 PCF4 PCF3 PCF2 PCV6W PCV6 PCV5 PCV4 PCV3 PCV2 PCV1
361 mm (H) x 272 mm (V) (Equivalent to scanning area of 1/4" pick-up tube)
525 lines / 60 fields / 30 frames
15.734 kHz
59.94 kHz
1.0 V (p-p) NTSC Composite 75 ohms / BNC Connector
330 lines (at center area)
46 dB (with AGC OFF)
0.5 Footcandle (5 Lux) at F2.0 0.5 Footcandle (5 Lux) at F2.0 - 1.0 Footcandle (10 Lux) at F2.8
Horizontal Angular Field of View
Horizontal 53.4˚ Horizontal 51.7 - 26.7˚ Vertical 40.0˚ Vertical 38.4 - 20.0˚ On (Preset)
ELC
-10˚C - +50˚C (14˚F - 122˚F)
24 VAC, 40 ma 12 VDC, 80 ma
W H D kg lbs
2.82" 4.6" 2.82"
6.0" 10.8" 7.0" 0.45 1 0.45 1 1.8 4 0.45 1 0.45 1 0.45 1 0.45 1 1.8 4 0.68 1.5 0.68 1.5 0.68 1.5 0.68 1.5 0.91 2 0.91 2
6.0" 6.0" 6.0"
3.15" 4.9" 3.2"
5.25" 3.0" 3.625"
15.9" 11.2" 15.9"
6.0" 6.0" 6.0"
6.0" 10.8" 7.0"
2.82" 4.6" 2.82"
6.0" 6.0" 6.0"
3.15" 4.9" 3.2"
5.25" 3.0" 3.625"
15.9" 11.2" 15.9"
6.0" 6.0" 6.0"
Connections CAUTION: To prevent fire or shock hazard, the UL-Listed wire VW-1, style 1007, should be used for the cable for
24 VAC input terminals.
This Chart is based on a 12VDC power supply with the maximum Amp draw at .500 amps.
Power Connections NOTE: Splice wiring according to standard electrical guidlines. Positive and Negative connections are interchangeable with this PC Board.

SAFETY PRECAUTIONS IMPORTANT SAFEGUARDS 1. Read Instructions - All the safety and operating instructions should be read before the unit is operated. 2. Retain Instructions - The safety and operating instructions should be retained for future reference. 3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to. 4. Follow Instructions - All operating and user instructions should be followed. 5. Electrical Connections - Only a qualified electrician should make electrical connections. 6. Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards. 7. Cable Runs - All cable runs must be within permissible distance. 8. Mounting - This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of the unit. Accordingly:
The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of non-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
a. The installation should be made by a qualified service person, and should conform to all local codes. b. Care should be exercised to select suitable hardware to install the unit, taking into account both the composition of the mounting surface and the weight of the unit. Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the installation is intact. Failure to comply with the foregoing could result in the unit separating from the support structure and falling, with resultant damages or injury to anyone or anything struck by the falling unit.
The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper.
Be sure to save: 1. The shipping carton and packaging material. They are the safest material in which to make future shipments of the equipment. 2. These Installation and Operating Instructions.
SERVICE For service on Panasonic/Videolarm equipment contact:
Panasonic Technical Center 54 West Gude Dr. Rockville MD 20850-1150
1-800-528-6747 9:00 AM - 5:00 PM EASTERN TIME
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.