FP2/FP2SH Series Programmable Controllers 08/2007.
T op Performance, Full Range of Functions CPU Units 2 CPU units Selectable fr om six types, accor ding to the application There are six types of CPU units, including the standard type and the type with preinstalled commonly-used advanced functions. This selection allows for more economical system development according to the application.
T op Performance, Full Range of Functions 3 Flexible Expandability Memor y and I/O Contr ol FP2SH Industry‘s highest class pr ocessing speed Adequate programming capacity Memory and I/O control .
4 Optimal Combination with Servo Drives P ositioning 4 "RTEX" positioning units Compatible with Realtime Express MINAS A4N* network serv o systems. Facilitate m ulti-axis high precision positioning High-accuracy multi-axis positioning control achieved by high-speed 100Mbps communication.
Optimal Combination with Servo Drives 5 High-Speed, High-Precision Positioning P ositioning 2 axes: FP2-PN2AN 4 axes: FP2-PN4AN 8 axes: FP2-PN8AN Monitoring LEDs • Status indicator • Link status • Error indicator • Pulser input status P ositioning units High-speed, high-accuracy pulse output type positioning unit.
6 Accurate Process Control Analog Contr ol 6 x Analog control Multi-range control of a v ariety of equipment is possible. The units can be directly connected with thermocouples and resistance temperature detectors Support voltage/current/temperature sensor ranges The analog input unit supports voltage, current, and temperature sensors.
Accurate Process Control 7 Connect all PLCs with Each Other Netw orking FP2 multi-wire link unit FP2 multi-wire link unit FP2 multi-wire link unit FP2 multi-wire link unit Analog input unit Analog out.
8 Continuous Communication in Industrial Applications Fle xib le Netw ork Slave Unit 8 The Flexible Network Slave (FNS) unit is a powerful, modular network unit used together with the programmable con- trollers FP2 and FP2SH.
Continuous Communication in Industrial Applications Program/Operate the PLC using an Ethernet Network FP W eb-Server 9 The multifunctional FP Web-Server provides users with the option of connecting any FP Series PLC to the Internet/Intranet for bi-directional communication via Ethernet.
10 Flexible Layout of I/O Devices Remote I/O Systems 10 Remote I/O systems MEWNET -F mode The number of I/O points can be increased up to 8192 and the transmission distance can be extended up to 700m by using the multi-wire link units. MEWNET -F is a remote I/O system that connects I/O units in separate locations with twisted-pair cables.
Flexible Layout of I/O Devices 1 1 Connect to V arious Serial Devices Serial Comm unication Serial communication control The CPU units have an RS232C port as standard equipment. The communication unit enab les connections with RS232C/RS485/ RS422-compatible de vices CPU units All CPU units have an RS232C port as standard equipment.
12 Basic CPUs FP2 12 The functions for a medium-scale PLC are squeezed into a compact bod y . P erfect when combining v arious devices. Features 1. Compact body The functions for a medium-scale PLC are squeezed into a compact body which requires minimal installation area (H: 100, W: 140, D: 108.
Basic CPUs 13 High-Performance CPUs FP2SH Serial Up to 1 backplane Units: 25 max. I/O points: 1,600 max. Remote I/O points: 8,192 max. Up to 3 backplanes Units: 32 max.
14 14 FP2/FP2SH Product Line and Accessories FP2/FP2SH system configurations and unit lineup Unit combinations Most units occupy one slot, i. e. module each, though some units occupy two slots. When selecting a backplane, carefully consider the units and number of slots you need.
15 Product Line and Accessories FP2/FP2SH FP2/FP2SH Product Line and Accessories Power supply units Input and output units Opti onal mem orie s For FP2SH T ype of memory unit Analog input/output units Positioning units Multi- communication unit Pulse input/ output units Link-related units CPU unit s FP2SH Back plan es H type backplanes 100V AC, 2.
16 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 16 Control FPWIN Pro Programming According to the International Standard IEC 61 131-3 FPWIN Pro is the Panasonic programming software developed according to the international standard IEC 61 131-3 (for Windows 98, NT V4.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 17 FP OPC Server and FP Data Analyzer Other software tools FP OPC Server Connects y our fav orite industrial application to FP2 or other FP Series PLCs The Panasonic FP O.
18 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 18 FP2-C2 FP2-C2P FP2-C3P F-ROM/EP-ROM Item Available Available 0.35 µ s or more 0.93 µ s or more 16k steps 32k steps Max.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 19 Specifications FP2/FP2SH Note 1: Current inputs can be converted into voltage inputs by attaching the supplied external resistor to the input terminal section.
20 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 20 Note 1: Current inputs can be converted into voltage inputs by attaching the supplied external resistor to the input terminal section.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 21 Specifications FP2/FP2SH ET -LAN units Multi-communication units Performance Specification T ransmission specifications for communication interface 16 − − − − − − Start-stop synchronization − − − − RS232C RS485 Note 1: The protocol can be downloaded from: www .
22 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 22 Multi-wire link units Performance Specification T ransmission specifications for communication interface 16 − − − − − − Start-stop synchronization − − − − RS232C RS485 Note 1: The protocol can be downloaded from: www .
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Item Transistor Line driver Output type Number of axes controlled Position command Speed command Acceleration/ deceleration command Home return Operation mode Startup time Output interface Feedback counter Other functions Internal current consumption (at 5 VDC) External power supply Command units Max.
24 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 24 CPU units (Built-in RAM) FP2 For FP2 FPSH From 0.35 µ s From 0.03 µ s 16k steps FP2-C1 FP2-C1D FP2-C1SL FP2-C2 FP2-C2P FP2-C3P 60k steps 60k steps 120k steps Not available Not available Not available Not available Available (See below .
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx FP2-MW FP2-C1SL FP2-SL2 Number of I/O points Not insulated V oltage: 1 to 5V , -10 to +10V Current: 4 to 20mA, -20 to +20mA Insulated V oltages, currents, thermocouples, resistance thermometer devices R.
26 Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 26 FP OPC Server FP OPC Server license FP Data Analyzer PCWA Y CommX Product name Description Product number Standardized connectivity to FP Series PLCs.
Xxxxx Xxxxxxxx Xxxxx Xxxxxxxx 27 Dimensions FP2/FP2SH DIN rail mounting groove (35-mm wide DIN EN50022) * The illustration shows a conventional 7-module type backplane.
Copyright © 2007 • Printed in Ger many 4193 euen 08/07 Asia Pacific China Japan North America Europe Global Netw ork P anasonic Electric W orks Please contact our Global Sales Companies in: Europe Headquarters Panasonic Electric W orks Europe AG Rudolf-Diesel-Ring 2, 83607 Holzkirchen, T el.
An important point after buying a device Panasonic FP2SH (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Panasonic FP2SH yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Panasonic FP2SH - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Panasonic FP2SH you will learn all the available features of the product, as well as information on its operation. The information that you get Panasonic FP2SH will certainly help you make a decision on the purchase.
If you already are a holder of Panasonic FP2SH, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Panasonic FP2SH.
However, one of the most important roles played by the user manual is to help in solving problems with Panasonic FP2SH. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Panasonic FP2SH along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center