CheetahSwitch Workgroup-3726M Intelligent/Stackable Fast Ethernet Switch with 24 10BASE-T / 100BASE-TX (RJ-45) Ports, and Optional Media Expansion and Stack Modules

Copyright © 2002 by Accton Technology Corporation. All rights reserved.
No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation.
Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes.
On-line Registration For quick warranty registration, log on our website at http://register.acctontech.com to register your Accton products.
International Headquarters No. 1 Creation Road III, Science-based Industrial Park Hsinchu 300, Taiwan, R.O.C. Phone: +886-3-5770-270 Fax: +886-3-5770-267 Internet: support@accton.com.tw
Europe Headquarters Edificio Conata II, Calle Fructuós Gelabert 6-8, 2o, 4a, 08970 - Sant Joan Despí, Barcelona, Spain. Phone: +34-93-477-4920 Fax: +34-93-477-3774
Asia Pacific Headquarters 1 Claymore Drive #08-05/06 Orchard Towers (Rear Block) Singapore 229594 Phone: +65 238 6556 Fax: +65 238 6466 Internet: www.acctontech.com
USA Headquarters 6 Hughes Irvine, CA 92618 Phone Numbers:
Accton is a trademark of Accton Technology Corporation. Other trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies.

Accton Technology Corporation
Limited Warranty: Accton warrants all is products to be free of manufacturing defects in workmanship and materials, under normal use and service, for the applicable warranty term. All Accton products carry a standard 90-day limited warranty from the date of purchase from Accton or its Authorized Reseller. Accton may, at its own discretion, repair or replace any product not operating as warranted with a similar or functionally equivalent product, during the applicable warranty term.
The standard limited warranty can be upgraded to a Limited Lifetime* warranty by registering new products within 30 days of purchase from Accton or its Authorized Reseller. Registration can be accomplished via the enclosed product registration card or online via the Accton web site. Failure to register will not affect the standard limited warranty. The Limited Lifetime warranty covers a product during the Life of that Product, which is defined as the period of time during which the product is an ‘Active’ Accton product. A product is considered to be ‘Active’ while it is listed on the current Accton price list. As new technologies emerge, older technologies become obsolete and Accton will, at its discretion, replace an older product in its product line with one that incorporates these newer technologies. At that point, the obsolete product is discontinued and is no longer an ‘Active’ Accton product. A list of discontinued products is attached with the firmware, configuration information, or memory data of Customer contained in, stored on, or integrated with any products returned to Accton pursuant to any warranty. Products returned to Accton should have any customer-installed accessory or add-on components, such as expansion modules, removed prior to returning the product for replacement. Accton is not responsible for these items if they are returned with the product.
Customers must contact Accton for a Return Material Authorization number prior to returning any product to Accton. Proof of purchase may be required. Any product returned to Accton without a valid Return Material Authorization (RMA) number clearly marked on the outside of the package will be returned to customer at customer’s expense. Customers are responsible for all shipping charges from their facility to Accton. Accton is responsible for return shipping charges from Accton to customer.
WARRANTIES EXCLUSIVE: IF AN ACCTON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUSTOMER’S SOLE REMEDY SHALL BE REPAIR OR REPLACEMENT OF THE PRODUCT IN QUESTION, AT ACCTON’S OPTION. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. ACCTON SHALL NOT BE

LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER'S OR ANY THIRD PERSON'S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.
LIMITATION OF LIABILITY: IN NO EVENT, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), SHALL ACCTON BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE, LOSS OF BUSINESS, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF ACCTON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
SOME COUNTRIES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS.
* Accton will provide warranty service for up to three years following discontinuance from the active Accton price list. Under the limited lifetime warranty, internal and external power supplies, fans, and cables are covered by a standard one-year warranty from date of purchase.

Installing the Switch 2 Package Contents 2 Description of Hardware 2 Mounting the Switch 3 Stacking Switches on a Flat Surface 3 Mounting Switches in a Rack 4 Installing a Management Module 4 Installing Optional Media and Stacking Modules 4 Connecting to the Stack’s Backplane 5 Connecting the Switch System 6 Making a Connection to an RJ-45 Port 6 Connecting to a 100BASE-FX Port 7 Connecting to a Gigabit Fiber Optic Port 7 Powering On the Switch 8 Verifying Port Status 9 Verifying System Operation 9 Applications 10
Product Specifications 11 Base Unit 11 Physical Characteristics 11 Switching Criteria 12 Traffic Control 12 Modules 12 Management Module (AC-ES3726M-AGENT) 12 100BASE-FX Module (EM3582-FX-SC) 12 1000BASE-SX Module (EM4582-SX-SC) 13 1000BASE-LX Module (EM4582-LX-SC) 13 Stacking Module (EM3580-STACK) 13
Troubleshooting 13 Diagnosing Switch Indicators 13 Power and Cooling Problems 14 Installation 14
Port and Cable Assignments 15 RJ-45 Port Description 15 Straight-Through Wiring 15 Crossover Wiring 15
EMI Certification 16 FCC Class A Certification (USA) 16

Canada Department of Communications - Class A 16 BSMI Class A (Taiwan) 16 VCCI Class A Compliance (Japan) 16 CE Mark Declaration of Conformance for EMI and Safety (EEC) 17
Safety Compliance 18 Warning: Fiber Optic Port Safety 18 Avertissment: Ports pour fibres optiques - sécurité sur le plan optique 18 Warnhinweis: Faseroptikanschlüsse - Optische Sicherheit 18 Underwriters Laboratories Inc. (USA) 18 Wichtige Sicherheitshinweise (Germany) 19
Contents

The CheetahSwitch Workgroup-3726M is perfect for moving workgroups from conventional 10 Mbps Ethernet to multiple-segment 100 Mbps Fast Ethernet, and for consolidating your network equipment into a single, clean, efficient, and super-fast switch stack. This switch system delivers dedicated 100 Mbps links to each attached LAN segment (independent collision domain) or to any PC attached directly to the stack – all with conventional cabling and adapters. It completely eliminates the bottlenecks of shared 10 Mbps Ethernet networks by providing a wide bandwidth of up to 8.8 Gbps per switch, and a stack backplane that can operate at up to 9.6 Gbps. This makes it ideal for increasing the throughput of interconnected Ethernet and Fast Ethernet hubs or server farms.
This switch includes three slots on the rear panel for various modules:
When the Management Module is installed, this system can provide a wide array of advanced features:
* This feature is not supported in the current firmware release.
The agent module allows you to configure or monitor the switch using the embedded management program or SNMP/RMON applications. To manage the switch, you can make a direct connection to the console port. You can also make a network connection to manage the switch using Telnet, the Web agent, or Accton’s free Windows-based network management software called AccView/Open.

Before installing the switch verify that you have all the items listed under “Package Contents.” If any of the items are missing or damaged, contact your local Accton distributor. Also be sure you have all the necessary tools and cabling before installing the switch. Note that this switch can be installed on any suitably large flat surface or in a standard EIA 19-inch rack. After installing the switch, refer to the Management Guide to set up its more advanced features, such as Spanning Tree Protocol or VLAN port groups.
This package includes:
The base unit contains 24 10BASE-T/100BASE-TX ports, plus three slots on the rear panel for various modules. A Management Module can be installed in the upper slot on the rear panel (see “Installing a Management Module” on page 4). The lower-left slot can be used for an optional media expansion module or Stacking Module, while the lower-right slot can be used for a media expansion module. Note that the media expansion modules include a Fast Ethernet fiber optic module with two 100BASE-FX (SC type) ports or a one port Gigabit 1000BASE-SX (SC type), or 1000BASE-LX uplink module.
All RJ-45 ports on the base unit operate at 10 or 100 Mbps, and support auto-negotiation of speed, duplex mode (i.e., half or full duplex), and flow control.
The 1000BASE-SX and 1000BASE-LX ports are fixed at 1000 Mbps but auto-negotiate duplex mode. The 100BASE-FX module is fixed at the 100 Mbps, full duplex. All media types can auto-negotiate flow control.
The base unit also includes a display panel for key system and port indications that simplify installation and network troubleshooting.

The following figure shows the components of this switch system:
Indicators 10/100 Mbps RJ-45 Ports
V A 3.3 15 5 3 12 0.7
Mounting the Switch
This switch can be placed directly on your desktop, or mounted in a rack.
Before you start installing the switch, make sure you can provide the right operating environment, including power requirements, sufficient physical space, and proximity to other network devices that are to be connected. Verify the following installation requirements:
The CheetahSwitch can be stacked anywhere there is enough flat space, such as on a table or desktop.

Mounting Switches in a Rack Please comply with the following instructions to ensure that your switch is securely mounted in the rack.
One Management Module is required to manage all of the switches in the stack. A Management Module only installs in a switch’s rear-panel upper slot, do not try to install it in either of the two lower slots.
You can install a Management Module as described below:
before installing any of these modules.
The two lower slots on the rear panel of the switch are provided for various optional media expansion modules (100BASE-FX or Gigabit) or Stacking Modules. The 100BASE-FX fiber optic module can be used to connect to remote sites, and a Gigabit module can be used as a network backbone. You can install the media expansion modules in either of the two lower slots, but the Stacking Module must only be installed in the lower-left slot.

You can install a module as described below:
The slide-in modules are not hot-swappable. Be sure you power off the switch before installing any of these modules.
Plug one end of the stack cable (provided with the package) in the “Down” port of the top unit and the other end to the “Up” port of the next unit. Repeat this step for each unit in the stack. Form a simple chain starting at the Down port on the top switch and ending at the Up port on the bottom switch (stacking up to 4 units).
Installing the Switch

The CheetahSwitch Workgroup-3726M provides 24 RJ-45 ports on the base unit. Each of these ports supports a connection to 10 Mbps Ethernet or 100 Mbps Fast Ethernet, and supports full or half-duplex operation. The transmission speed for each port is automatically set by the switch to match the highest speed supported by the connected device. The transmission mode can be set for each port using auto-negotiation (if also supported by the attached device). However, if the device attached to any port on the switch does not support auto-negotiation, you can manually configure the transmission mode via the console port on the rear panel, or via an in-band connection (including Telnet, the Web agent or management software).
You can use straight-through twisted-pair cable to connect any RJ-45 (MDI-X) port on the switch to any device that uses a standard network interface such as a workstation or server, or to a network interconnection device such as a bridge or router (depending on the port type implemented).
1. Prepare the network devices you wish to network. Make sure you have installed 10BASE-T or 100BASE-TX network interface cards for connecting to the switch’s RJ-45 (MDI-X) station ports. 2. Prepare straight-through shielded or unshielded twisted-pair cables with RJ-45 plugs at both ends. Use 100-ohm Category 3, 4 or 5 cable for standard 10 Mbps Ethernet connections, or 100-ohm Category 5 cable for 100 Mbps Fast Ethernet connections. 3. Connect one end of the cable to the RJ-45 port of the network interface card, and the other end to any available RJ-45 port on the switch. All RJ-45 ports support 10 Mbps and 100 Mbps Ethernet connections. When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to ensure that it is properly seated. Using the switch in a stand-alone configuration, you can network up to 24 end nodes.
switch. Instead, use only twisted-pair cables with RJ-45 connectors that conform with FCC standards.
Notes: 1. When connecting to another compatible switch or hub, use straight-through cable to connect to an MDI port on the other device. You may also attach to MDI-X station ports at both ends if you use crossover cabling. (Refer to “Port and Cable Assignments” on page 15 for a description of crossover cable.) 2. Make sure each twisted-pair cable does not exceed 100 meters (328 feet). 3. We advise using Category 5 cable for all network connections to avoid any confusion or inconvenience in the future when you upgrade attached devices to Fast Ethernet.
Restrictions on Cascade Length - The IEEE 802.3 standard recommends restricting the number of hubs (i.e., repeaters) cascaded via twisted-pair cable to 4; while IEEE 802.3u provides even stricter recommendations for Fast Ethernet. Therefore, when cascading devices other than this switch, please refer to the accompanying documentation for cascade restrictions. However, note that because

switches break up the path for connected devices into separate collision domains, you should not include the switch or connected cabling in your calculations for cascade length involving other devices.
If you connect fiber cable to the 100BASE-FX module, be sure you use an SC-type connector. When inserting the cable, be sure the tab on the plug clicks into position to ensure that it is properly seated. If you use an SC-to-ST converter, run cable from the Rx (Tx) port on the module to the Tx (Rx) port on the target device. Note that the fiber optic ports operate only at 100 Mbps, full duplex. In this mode, you can run a fiber optic link up to 2 kilometers (1.24 miles).
the switch before installing any of these modules.
Connecting to a Gigabit Fiber Optic Port When connecting fiber cable to a Gigabit fiber-optic port on the switch, be sure you use an SC-type connector. Follow the steps below.
compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However, you should never look directly at a transmit port when it is powered on.
All the SC-type ports operate at 1000 Mbps with support for auto-negotiation of duplex mode (full/half) and flow control. Also note the maximum length for
Installing the Switch

1000BASE-SX and 1000BASE-LX fiber optic cable depends on the core size and the rating of the cable, as shown in the following tables.
Maximum 1000BASE-SX Gigabit Ethernet Cable Length
Fiber Size Fiber Bandwidth Maximum Cable Length
62.5/125 micron multimode fiber
160 MHz/km 2-220 m (7-722 ft)
200 MHz/km 2-275 m (7-902 ft)
50/125 micron multimode fiber
400 MHz/km 2-500 m (7-1641 ft)
500 MHz/km 2-550 m (7-1805 ft)
Maximum 1000BASE-LX Gigabit Ethernet Cable Length
Fiber Size Fiber Bandwidth Maximum Cable Length
9/125 micron singlemode fiber
N/A 2 m - 5 km (7 - 16404 ft)

Check each connection by viewing the port indicators on the base unit front panel. Their staus is shown in the following table.
LED S tate Indication System Power On Switch is receiving power. RDP On Redundant power unit on. Mgmt On Management agent operational. RJ-45 Ports Link On Port has established a valid network connection. Yellow Communications have been set to 10 Mbps. Green Communications have been set to 100 Mbps. Flashing Port has been manually disabled, or partitioned by the system due to excessive errors. Activity* On Traffic is passing through the port. FDX* On Port has been set to full duplex. FC* On Flow control enabled. Module Ports Status On A valid module is correctly installed in the slot. Activity On Traffic is passing through the port. * Use the Mode Select button to select LED display mode.
Verify that the stack has at least one Management Module correctly installed and operating. The “Mgmt” LED on the switch that contains the Management Module should be on, indicating that the module is installed and operating correctly.
Verify that the stack connections are operating correctly. Each switch in the stack has it’s own unique unit ID (a number from 1 to 4) displayed by the front-panel LCD labeled “Switch ID.” If any switch in the stack displays a flashing or unstable unit ID for more than 30 seconds, you should check the following items:
Verify that any optional modules are installed correctly. The Module 1 or Module 2 “Status” LEDs on the switch panel should be on, indicating that the modules are installed and operating correctly.
Verify that all attached devices have a valid connection. The switch monitors the link status for each port. If any device is properly connected to the switch and transmitting a link signal, the Link indicator will light up for the corresponding port. If the Link indicator fails to light when you connect a device to the switch, check the following items:
Installing the Switch

This switch segments your network, significantly increasing both bandwidth and throughput. Any port on the switch can be attached to a hub (a shared collision domain) or provide a dedicated link to a single network device (such as a workstation or server). When a port on the switch is connected to a hub (a 10 or 100 Mbps repeater), the bandwidth provided by that port is shared by all the devices connected to the attached hub. However, when a port is connected to an end node or to a device that breaks up the collision domain (e.g., another switch, bridge or router), the attached device has access to the full bandwidth provided by that port.
Bridging Functions - This switch provides fully transparent bridging functions. It automatically learns node addresses, that are subsequently used to filter and forward all traffic based on the destination address. When traffic passes between devices attached to the same shared collision domain, those packets are filtered from the switch. But when traffic must be passed between unique segments (i.e., different ports on the switch), the high-speed switching fabric forwards the packets at near zero latency.
Switching Functions - Store-and-forward switching is used to forward traffic to other ports. This scheme ensures data integrity and provides a clean data stream.
Flexible Configuration - This switch is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. It can be used as a simple stand-alone switch; stacked up to four high; or connected with standard repeater hubs, switches, or other network interconnection devices in various configurations.
Media Expansion Options - You can use a Fast Ethernet fiber module to connect to remote sites up to 2 kilometers (1.24 miles) away, or a Gigabit module to support applications such as high-speed file servers, or for connecting to a collapsed Gigabit backbone switch.

Switch at remote site (via fiber link)
Collapsed Backbone (via Gigabit link)
Physical Characteristics
Access Method CSMA/CD Standards Conformance IEEE 802.3, IEEE 802.3u Communication Rate 10/100 Mbps Communication Mode Full or half duplex Media Supported 10BASE-T - 100-ohm Category 3,4,5 twisted-pair cable 100BASE-TX - 100-ohm Category 5 twisted-pair cable Number of Ports 24 RJ-45 100BASE-TX ports Indicator Panel System: Power, RDP, Mgmt; Ports: link/speed/disabled/ partitioned, activity, duplex, flow control Dimensions 440 x 285 x 64 mm (17.37 x 11.22 x 2.53 in.) Weight 4.5 kg (9.92 lb) Input Power Full range: 100 to 240 V (±10%), 50 to 60 Hz (±3 Hz) Maximum Current 0.80 ARMS max.@110 V, 0.50 ARMS max.@240 V Power Consumption 70 Watts max. @ 100-240 VAC Heat Dissipation 239 BTU/hr max. @ 100-240 VAC

Temperature Operating: 0~50 °C / 32~122 °F Storage: -40~70 °C / -40~158 °F Humidity 5% to 95% (noncondensing) Certification CE Mark Emissions FCC Class A, VCCI Class A, CISPR Class A, EN 61000-3-2/3 Immunity IEC 61000-4-2/3/4/5/6/11 Safety CSA/NRTL, TÜV/GS
Network Bridging Function Filtering, forwarding and learning Switching Method Store-and-forward Address Table 8K entries total Queue Buffer 128K bytes per 10/100 Mbps port 2M bytes for 1000 Mbps port Address Resolution Fast hashing scheme
Flow Control Back pressure for half duplex IEEE 802.3x for full duplex Broadcast Suppression Broadcast traffic suppressed at configurable threshold
System Configuration Configuration via console connection to serial port or via Telnet; Web-based management via HTTP protocol to access embedded management program; Full-featured SNMP/RMON management using network management software Management Agent MIB support: MIB II (RFC1213), Bridge MIB (RFC 1493), Ethernet-like MIB (RFC1643), RMON MIB (RFC1757), and Accton ’s private MIB RMON Groups 1,2,3,9 (Statistics, History, Alarm, Event)
Access Method CSMA/CD Standards Conformance IEEE 802.3u 100BASE-FX Communication Rate 100 Mbps Communication Mode Full duplex Media Supported 50/125 micron or 62.5/125 micron multimode fiber Output Power Minimum: -19 dBm, Maximum: -14 dBm Receiver Sensitivity Minimum: -33 dBm, Saturation: -14 dBm Power Budget 19 dBm Number of Ports 2 100BASE-FX SC-type ports Indicator Panel Included on base unit
Management Module (AC-ES3726M-AGENT) · 100BASE-FX Module (EM3582-FX-SC)

1000BASE-SX Module (EM4582-SX-SC) Access Method CSMA/CD Standards Conformance IEEE 802.3z Communication Rate 1000 Mbps Communication Mode Full or half duplex Media Supported 50/125 micron or 62.5/125 micron multimode fiber Output Power Minimum: -9.5 dBm, Maximum: -4 dBm Receiver Sensitivity Minimum: -20 dBm, Saturation: -3 dBm Power Budget 16 dBm Number of Ports 1 1000BASE-SX (SC-type) port Indicator Panel Included on base unit
Access Method CSMA/CD Standards Conformance IEEE 802.3z Communication Rate 1000 Mbps Communication Mode Full or half duplex Output Power Minimum: -9.5 dBm, Maximum: -3 dBm Receiver Sensitivity Minimum: -20 dBm, Saturation: -3 dBm Power Budget 17 dBm Media Supported 9/125 micron singlemode fiber Number of Ports 1 1000BASE-LX (SC-type) port Indicator Panel Included on base unit
Number of Ports Two 68-pin, SCSI connectors Cable Type SCSI Type 4, length 30 cm Backplane Bandwidth 9.6 Gbps
The switch can be easily monitored through panel indicators to assist the network manager in identifying problems. This table below describes common problems you
may encounter and possible
Troubleshooting · Stacking Module (EM3580-STACK)

Power indicator does not light up after power on.
Power outlet, power cord, or internal power supply may be defective.
Check the power outlet by plugging in another device that is functioning properly. Check the power cord with another device. If these measures fail to resolve the problem, contact your Accton distributor.
Link indicator does not light up after making a connection.
Network interface (e.g., a network adapter card on the attached device), network cable, or switch port may be defective.
Verify that the switch and attached device are powered on. Be sure the cable is plugged into both the switch and corresponding device. Verify that the proper cable type is used and its length does not exceed specified limits. Check the adapter on the attached device and cable connections for possible defects. Replace the defective adapter or cable if necessary.
Mgmt indicator does not light up after power on.
A Management Module is not installed correctly, or may have failed.
Check that the Management Module is correctly installed in the upper slot on the switch rear panel (at least one Management Module is required in a switch stack). Test the Management Module by installing it in another switch unit. If these measures fail to resolve the problem, contact your Accton distributor.
Module 1/2 Status indicator does not light up after power on.
A optional module is not installed correctly, or may have failed.
Check that the module is correctly installed in one of the two lower slots on the switch rear panel. Test the module by installing it in another switch unit. If these measures fail to resolve the problem, contact your Accton distributor.
Switch ID LCD does not display a stable unit number.
The switch stack has not initiated properly.
Reset the stack by powering off each switch unit in the stack and then powering them back on. Check all Stacking Modules are installed correctly in the lower-left slot on the rear panel of each switch. Check that all stacking cables are connected correctly. If these measures fail to resolve the problem, contact your Accton distributor.
If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on the right side of the unit are unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact your Accton distributor for assistance.
Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (e.g., the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.
Symptom Cause Solution

Port and Cable Assignments
RJ-45 station ports (MDI-X) can be attached to any devices that use a standard network interface (e.g., a workstation, server, bridge or router). RJ-45 daisy-chain ports (MDI) can be cascaded to a station port on similar networking devices (e.g., another switch or hub). Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections: 100-ohm Category 3, 4 or 5 cable for 10 Mbps connections or 100-ohm Category 5 cable for 100 Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).
Pin MDI-X Signal Name MDI Signal Name 1 Receive Data plus (RD+) Transmit Data plus (TD+) 2 Receive Data minus (RD-) Transmit Data minus (TD-) 3 Transmit Data plus (TD+) Receive Data plus (RD+) 6 Transmit Data minus (TD-) Receive Data minus (RD-) 4,5,7,8 Not Used Not Used
If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through.
Straight-Through RJ-45 Pin Assignments End 1 End 2 1 (RD+) 1 (TD+) 2 (RD-) 2 (TD-) 3 (TD+) 3 (RD+) 6 (TD-) 6 (RD-)
If the twisted-pair cable is to join two ports and either both ports are labeled with an “X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover must be implemented in the wiring.
Crossover RJ-45 Pin Assignments End 1 End 2 1 (TD+) 3 (RD+) 2 (TD-) 6 (RD-) 3 (RD+) 1 (TD+) 6 (RD-) 2 (TD-)

Warning: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures are required to correct the interference.
You may use unshielded twisted-pair (UTP) for RJ-45 connections - Category 3 or greater for 10Mbps connections, and Category 5 for 100Mbps connections. For fiber optic connections, you may use 50/125 or 62.5/125 micron fiber.
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications.
Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur : “Appareils Numérques,” NMB-003 édictée par le ministère des Communications.
BSMI Class A (Taiwan)

VCCI Class A Compliance (Japan)


CE Mark Declaration of Conformance for EMI and Safety (EEC)
This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the compliance with these Directives, the following standards were applied:
EMI Certification

When using a fiber optic media expansion module, never look at the transmit laser while it is powered on. Also, never look directly at the fiber TX port and fiber cable ends when they are powered on.
Ne regardez jamais le laser tant qu’il est sous tension. Ne regardez jamais directement le port TX (Transmission) à fibres optiques et les embouts de câbles à fibres optiques tant qu'ils sont sous tension.
Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist. Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind.
Operating Voltage Cord Set Specifications 120 Volts UL Listed/CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord Maximum length of 15 feet Parallel blade, grounding type attachment plug rated 15A, 125V 240 Volts (Europe only) Cord Set with H05VV-F cord having three conductors with minimum diameter of 0.75 mm2 IEC-320 receptacle Male plug rated 10A, 250V

AC-ES3726M-AGENT: SNMP/RMON Management Module with RS-232 Port EM3582-FX-SC: Media Module with 2 100BASE-FX (SC-type) Ports EM4582-SX-SC: Media Module with 1 1000BASE-SX (SC-type) Port EM4582-LX-SC: Media Module with 1 1000BASE-LX (SC-type) Port EM3580-STACK: Stacking Module kit including 30 cm stacking cable RPU150W: Redundant Power Supply ST5002: SC to ST Plug Converter for Fiber Optic Module (for 62.5/125 micron cable only)



Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Power indicator does not light up after power on. | Power outlet, power cord, or internal power supply may be defective. | Check the power outlet by plugging in another device that is functioning properly. Check the power cord with another device. If these measures fail to resolve the problem, contact your Accton distributor. | p.22 |
| Link indicator does not light up after making a connection. | Network interface (e.g., a network adapter card on the attached device), network cable, or switch port may be defective. | Verify that the switch and attached device are powered on. Be sure the cable is plugged into both the switch and corresponding device. Verify that the proper cable type is used and its length does not exceed specified limits. Check the adapter on the attached device and cable connections for possible defects. Replace the defective adapter or cable if necessary. | p.22 |
| Mgmt indicator does not light up after power on. | A Management Module is not installed correctly, or may have failed. | Check that the Management Module is correctly installed in the upper slot on the switch rear panel (at least one Management Module is required in a switch stack). Test the Management Module by installing it in another switch unit. If these measures fail to resolve the problem, contact your Accton distributor. | p.22 |
| Module 1/2 Status indicator does not light up after power on. | A optional module is not installed correctly, or may have failed. | Check that the module is correctly installed in one of the two lower slots on the switch rear panel. Test the module by installing it in another switch unit. If these measures fail to resolve the problem, contact your Accton distributor. | p.22 |
| Switch ID LCD does not display a stable unit number. | The switch stack has not initiated properly. | Reset the stack by powering off each switch unit in the stack and then powering them back on. Check all Stacking Modules are installed correctly in the lower-left slot on the rear panel of each switch. Check that all stacking cables are connected correctly. If these measures fail to resolve the problem, contact your Accton distributor. | p.22 |
| Power and Cooling Problems If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fans on the right side of the unit are unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact your Accton distributor for assistance. Installation Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (e.g., the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly. | p.22 |
Owners and our team usually reply within a day — and your question helps the next person too.