Page 1 of the Accton Technology Network Switch (-2041) user manual — EH2041S E0898-R02
Page 1 · click to enlarge
Page 1

CheetaHub Classic-2041 Quick Installation Guide

EH2041S E0898-R02

Page 2 of the Accton Technology Network Switch (-2041) user manual — EH2041S E0898-R02
Page 2 · click to enlarge
Page 2

Copyright © 1998 by Accton Technology Corporation. All rights reserved.

No part of this document may be copied or reproduced in any form or by any means without the prior written consent of Accton Technology Corporation.

Accton makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. Accton reserves the right to make revisions to this publication without obligation to notify any person or entity of any such changes.

CheetaHub Classic-2041 Smart Ethernet Hub with 16 10BASE-T (RJ-45) ports, 1 10BASE2 (BNC) port, and 1 AUI port

International Headquarters USA Headquarters No. 1 Creation Road III, P.O. Box 51420 Science-based Industrial Park Irvine, CA 92619-1420 Hsinchu 300, Taiwan, R.O.C. Phone Numbers - Phone: 886-3-5770-270 Sales: 888-398-2101 or 949-707-4800 FAX: 886-3-5770-267 Support: 888-398-4101 or 949-707-4847 BBS: 886-3-5770-654 RMA: 888-398-3101 or 949-707-4828 Internet: support@accton.com.tw FAX: 949-707-2460

Accton is a trademark of Accton Technology Corporation. Other trademarks or brand names mentioned herein are trademarks or registered trademarks of their respective companies.

EH2041S E0898-R02

Page 3 of the Accton Technology Network Switch (-2041) user manual — Warranty 9
Page 3 · click to enlarge
Page 3

Contents

The CheetaHub Classic-2041 includes 16 RJ-45 ports, 1 BNC port for connection to thin Ethernet (10BASE2), and 1 AUI port for connection to a variety of media types including 10BASE5 or fiber (using a suitable transceiver). With these options, you can easily link the hub to a thin or thick Ethernet backbone, or connect to a remote office. The hub also has an indicator panel that includes utilization and link/traffic LEDs, making it easy to monitor the hub. This guide contains all the information required to install and operate the hub.

Introduction 1

Package Contents 1

Description of Hardware 1

Mounting the Hub 1 Stacking Hubs on a Flat Surface 2 Mounting Hubs in a Rack 2

Connecting the Hub System 2 Making a Connection via an MDI-X Station Port 2 Making a Connection via the MDI Daisy-Chain Port 3 Making a Connection to the BNC Port 3 Making a Connection to the AUI Port 3

The package includes:

  • CheetaHub Classic-2041 (Model No. EH2041S)
  • Four rubber foot pads
  • BNC connector
  • Rack mount bracket kit
  • Quick Installation Guide
  • AC power cord
  • Owner registration card

Powering on the Hub 3

Verifying Hub Status 4

This hub consists of 16 RJ-45 10Mbps ports, 1 BNC port, and 1 AUI port. The following figure shows the front and back panel of the hub:

Applications 4

Accton Technology Network Switch (-2041) — Applications 4 diagram (page 3)
Fig. 1 · Applications 4

Product Specifications 4 Base Unit 4 Network Criteria 5

Troubleshooting 5 Diagnosing Hub Indicators 5 Power and Cooling Problems 6 Installation 6

Port and Cable Assignments 6 RJ-45 Port Description 6

EMI Certification 6 FCC Class A (USA) 6 Class A (Canada Department of Communications) 7 Class A (Taiwan Bureau of Commodity Inspection) 7 Class A Compliance (Korea) 7 VCCI Class A Compliance (Japan) 7 CE Mark Declaration of Conformance for EMI and Safety (EEC) 7

This hub can be placed directly on your desktop, or mounted in a rack.

Before you start installing the hub, make sure you can provide the right operating environment, including power requirements, sufficient physical space, and proximity to other network devices that are to be connected. Verify the following installation requirements:

  • Power requirements: 100 to 240 VAC (± 10%) at 50 to 60 Hz (± 3Hz). The hub's power supply automatically adjusts to the input voltage level.
  • The hub should be located in a cool dry place, with at least 10 cm. (4 in.) of space at the front and back for ventilation.
  • Place the hub out of direct sunlight, and away from heat sources or areas with a high amount of electromagnetic interference.
  • If you intend to mount the hub in a rack, make sure you have all the necessary mounting screws, brackets, bolts and nuts, and the right tools.
  • Check if network cables and connectors needed for installation are available.

Safety Compliance 8 Underwriters Laboratories Inc. (USA) 8 Wichtige Sicherheitshinweise (Germany) 8

Warranty 9

Show 4 more labels / short text on this page
Introduction · Package Contents · Description of Hardware · Mounting the Hub
Page 4 of the Accton Technology Network Switch (-2041) user manual — Stacking Hubs on a Flat Surface
Page 4 · click to enlarge
Page 4

Stacking Hubs on a Flat Surface

Making a Connection via the MDI Daisy-Chain Port

This hub can be stacked anywhere there is a enough flat space, such as on a table or desktop.

1. To make a direct connection to a compatible hub or switch, use the MDI daisychain port (Port 16). When connecting to this port, remember to set the port selection switch to MDI. You can also connect any RJ-45 (MDI-X) port on the hub to an MDI daisy-chain port on the other device.
1. Stick the self-adhesive rubber foot pads (that come with this package) on each of the 4 concave spaces located on the bottom of the first hub. 2. Place the first hub on a firm flat surface where you want to install the stack. 3. Repeat step 1 for each hub before stacking them. The rubber foot pads cushion the hub against shock/vibrations and provide space between each hub for ventilation.
2. Prepare straight-through shielded or unshielded twisted-pair cables with RJ-45 plugs at both ends. Use 100 W Category 3, 4 or 5 cable for all RJ-45 connections. When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to ensure that it is properly seated. Notes: 1. To connect to another hub or switch, you may also attach to (MDI-X)

station ports at both ends if you use crossover cabling (see page 6). 2. When using Port 16 as an MDI port, set the port selection switch to 16MDI. 3. When connecting to another 10Mbps hub, you can cascade up to 4 hubs, and use up to 100 meters (328 feet) for each inter-hub link. 4. To achieve a larger network diameter, you should use a switch to connect several hubs (or stacks) together. Because a switch breaks up the path for connected devices into separate collision domains, it has no restrictions on cascade length.

Mounting Hubs in a Rack

Please comply with the following instructions to ensure that your hub is securely mounted in the rack.

1. Use a standard EIA 19-inch rack. 2. Use the brackets and screws supplied in the rack mounting kit. 3. Use a cross-head screwdriver to attach the brackets to the side of the hub. 4. Position the hub in the rack by lining up the holes in the brackets with the appropriate holes on the rack, and then use the supplied screws to mount the hub in the rack.

Making a Connection to the BNC Port

Plug the BNC T-type connector (provided with the hub) into a BNC port on the module. When connecting two devices via BNC ports, there should be at least 0.5 meters (1.64 feet) of coaxial cable between the two BNC ports. A thin Ethernet coaxial cable segment can be extended up to 185 meters (607 feet) and can link up to 30 nodes. If the unit is at the terminal end of a segment, connect a 50W terminator to the open end of the "T" connector.

Connecting the Hub System

This hub has 16 RJ-45 ports, one of which also serves as an (MDI) daisy-chain port. It also has one BNC port on the rear panel for connection to thin Ethernet (10BASE2), and one AUI port for connection to thick Ethernet (10BASE5) or fiber (10BASE-F).

Making a Connection to the AUI Port

Thick Ethernet - Attach an AUI to 10BASE5 transceiver to the thick Ethernet trunk, and then run an AUI drop cable (with 15-pin D-type connectors on both ends) between the AUI port on the hub and the transceiver. Note that the maximum length of an AUI drop cable is 50 meters (164 feet). A thick Ethernet segment can be extended up to 500 meters (1640 feet) and can link up to 100 nodes.

Making a Connection via an MDI-X Station Port

You can connect any RJ-45 (MDI-X) station port on the hub to any device that uses a standard network interface such as a PC or server, or to a network interconnection device such as a bridge or router (depending on the port type implemented).

Fiber - Attach a 10BASE-F fiber optic transceiver to the AUI port. Use 50/125µm or 62.5/125µm multi-mode fiber optic cabling with SC or ST-type connectors (depending on the transceiver). Run cabling from the TX/RX ports on this hub to the RX/TX ports on the other device. When inserting the cable, be sure the tab on the plug clicks into position to ensure that it is properly seated. Note that 10Mbps fiber can be extended up to 2 kilometers (1.24 miles).

1. Prepare the network devices you wish to network. Make sure you have installed 10BASE-T network interface cards for connecting to the hub's RJ-45 (MDI-X) station ports. You also need to prepare straight-through shielded or unshielded twisted-pair cables with RJ-45 plugs at both ends. Use 100 W Category 3, 4 or 5 cable for all RJ-45 connections.

Powering on the Hub

2. Connect one end of the cable to the RJ-45 port of the network interface card, and the other end to any available (MDI-X) station port on the hub. When inserting an RJ-45 plug, be sure the tab on the plug clicks into position to ensure that it is properly seated. Using the hub in a stand-alone configuration, you can network up to 16 end nodes. I Do not plug a phone jack connector into any RJ-45 port. This may damage the

1. Plug the power cord into the power socket at the rear of the hub, and the other end into a power outlet. 2. Turn on the power switch on the back of the hub. 3. Check the LED marked Power on the front panel to see if it is on. The unit will automatically select the setting that matches the connected input voltage. Therefore, no additional adjustments are necessary when connecting it to any input voltage within the range marked on the rear panel. Note: The unit supports a "hot remove" feature which permits you to connect/

hub. Instead, use only twisted-pair cables with RJ-45 connectors that conform with FCC standards. Notes: 1. Make sure each twisted-pair cable does not exceed 100 meters (328 feet).

disconnect RJ-45 or other media cables without powering off the hub and without disrupting the operation of the devices attached to the hub.

2. When using Port 16 as an MDI-X port, set the port selection switch to 16MDI-X.
Page 5 of the Accton Technology Network Switch (-2041) user manual — Verifying Hub Status
Page 5 · click to enlarge
Page 5

10BASE5 - thick Ethernet coaxial cable1, 10BASE-F - ST-type multimode fiber1

Check each connection by comparing the indicators with the following table.

(1: via suitable AUI transceiver) Number of Ports 16 RJ-45 ports, 1 BNC port, and 1 AUI port Indicator Panel Power, utilization, collisions, partition, link/traffic Dimensions 440 x 116 x 43 mm (17.32 x 4.58 x 1.69 in) Weight 1.8 kg (3.97 lb) Input Power 110~240 VAC, 50/60 Hz (built-in full-range power module) Power Consumption 16 Watts maximum Heat Dissipation 54.6 BTU/hr Temperature 0°C to 50°C (32 to 122°F) Standard Operating Humidity 5% to 95% (Non-condensing) Certification CE Mark Emissions FCC Class A, VCCI Class A, CISPR 22 Class A Immunity IEC 801-2/3/4 Safety UL, CSA, TÜV/GS

LED StateIndication Power OnHub receiving power. Collision FlashingTwo ormore devicesattempted to transmitdataatthe same time. (NormalsituationunderEthernetCSMA/CD.) Utilization OnIndicatespercentage ofLANbandwidthutilized. Partition OnPortpartitioned due to anabnormalnetworkcondition. Link/Traffic On FlashingPorthasestablished avalid networkconnection. Portisreceiving packets;blinking isproportionaltotraffic.

Hub-to-Workstation Distance 100 meters maximum using twisted-pair cable Inter-hub Distance (MDI Port) 100 meters using twisted-pair cable (4 hub cascade)

Flexible Configuration - This hub is not only designed to provide network access for 10Mbps connections, but also to provide a wide range of options in setting up network connections. It can be used as a simple stand-alone hub or stacked up to 10 high; or can be cascaded to any compatible hub or switch. A sample configuration diagram is shown in the following figure.

(100 meters = 328 feet) Troubleshooting

The hub can be easily monitored through panel indicators to assist the network manager in identifying problems. This section describes common problems you may encounter and possible solutions.

Accton Technology Network Switch (-2041) — Verifying Hub Status diagram (page 5)
Fig. 2 · Verifying Hub Status

Symptom: Power indicator does not light up (green) after power on. Cause: Defective power outlet, power cord, or internal power supply. Solution: Check the power outlet by plugging in another device that is functioning

properly. Check the power cord with another device. If these measures fail to resolve the problem, have the unit's power supply replaced by a qualified Accton distributor.

Symptom: Link indicator does not light up (green) after making a connection. Cause: Network interface (e.g., a network adapter card on the attached device),

network cable, or hub port is defective. Solution: Verify that the hub and attached device are powered on. Be sure the cable is

plugged into both the hub and attached device. Check the adapter on the attached device and cable connections for possible defects. See if your cable is functioning properly by using it for another port and attached device that displays valid indications when connected to the network. Replace the defective adapter or cable if necessary. Also verify that you have not exceeded specified limits for any attached media as summarized in the following table:

MediaTypeMaxLengthMaxNodesOther TwistedPair100meters(328feet)1000 ThinEthernet185meters(607feet)300.5meters1 ThickEthernet500meters(0.3miles)50050meters2 FiberOptic(10Mbps)2000meters(1.24miles)linkpair 1-Minimumdistancebetweennodes. 2-MaximumlengthofdropcablefromAUIporttotransceiver. (0.5meters=1.64feet;50meters=164feet)
Accton Technology Network Switch (-2041) — Verifying Hub Status diagram (page 5)
Fig. 3 · Verifying Hub Status

Access Method CSMA/CD, 10 Mbps Standards Conformance IEEE 802.3 10BASE-T, 10BASE2, 10BASE5 Communication Rate 10 Mbps Media Supported 10BASE-T - 100W Category 3,4,5 UTP/STP, 10BASE2 - thin Ethernet coaxial cable,

Show 6 more labels / short text on this page
Verifying Hub Status · Network Criteria · Applications · Diagnosing Hub Indicators · Product Specifications · Base Unit
Page 6 of the Accton Technology Network Switch (-2041) user manual — Power and Cooling Problems
Page 6 · click to enlarge
Page 6

Power and Cooling Problems

operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user, at his own expense, will be required to take whatever measures are required to correct the interference.

If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous section. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges at the power outlet, and verify that the fan on back of the unit is unobstructed and running prior to shutdown. If you still cannot isolate the problem, then the internal power supply may be defective. In this case, contact your Accton distributor for assistance.

You may use unshielded twisted-pair (UTP) for RJ-45 connections - Cat. 3 or greater.

Class A (Canada Department of Communications)

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus", ICES-003 of the Department of Communications.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: "Appareils Numérques", NMB-003 édictée par le ministère des Communications.

Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (e.g., the power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning properly.

Class A (Taiwan Bureau of Commodity Inspection)

Port and Cable Assignments

Accton Technology Network Switch (-2041) — Power and Cooling Problems diagram (page 6)
Fig. 4 · Power and Cooling Problems
Accton Technology Network Switch (-2041) — Power and Cooling Problems diagram (page 6)
Fig. 5 · Power and Cooling Problems

RJ-45 station ports (MDI-X) can be attached to any devices which use a standard network interface (e.g., a workstation, server, bridge or router). Similar networking devices (e.g., another hub or switch) can be cascaded by connecting the hub’s daisy-chain port (MDI) to an RJ-45 station port on the other device. Use 100W Category 3, 4 or 5 twisted-pair cable: unshielded or shielded (UTP/STP) cable for all RJ-45 connections on the front panel, and shielded (STP) cable for the stack ports on the rear panel. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet).

Class A Compliance (Korea)

Accton Technology Network Switch (-2041) — Power and Cooling Problems diagram (page 6)
Fig. 6 · Power and Cooling Problems
PinAssignment (StationPorts1-16) 1InputReceive Data+ 2InputReceive Data- 3OutputTransmitData+ 6OutputTransmitData- 4,5,7,8NotUsed

nia h C -y sia D ( tn e m n gis s A

VCCI Class A Compliance (Japan)

Accton Technology Network Switch (-2041) — Power and Cooling Problems diagram (page 6)
Fig. 7 · Power and Cooling Problems

CE Mark Declaration of Conformance for EMI and Safety (EEC)

Schematics for both straight and crossover twisted-pair cable are shown below.

This is to certify that this product complies with ISO/IEC Guide 22 and EN45014. It conforms to the following specifications:

h g u o r h T-th giart S re v o s s o r C )b u H ( )retp a d A( )b u H ( )b u H ( + D RI 1 + D T O 1 + D RI 1 + D RI 1 - D RI 2 - D T O 2 - D RI 2 - D RI 2 + D T O 3 + D RI 3 + D T O 3 + D T O 3 - D T O 6 - D RI 6 - D T O 6 - D T O 6

EMC: EN55022(1988)/CISPR-22(1985) class A EN60555-2(1995) class A EN60555-3 IEC1000-4-2(1995) 4kV CD, 8kV AD IEC1000-4-3(1995) 3V/m IEC1000-4-4(1995) 1kV - (power line), 0.5kV - (signal line) This product complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC.

FCC Class A (USA)

Warning: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device pursuant to Subpart B of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when

Installation · RJ-45 Port Description · EMI Certification

Ask about the Accton Technology Network Switch (-2041)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Accton Technology Network Switch (-2041)

Be the first to ask — other owners or our team will answer.

Original document

Accton Technology Network Switch (-2041) manual PDF

7 pages·955 KB·Network Hardware·PDF