Instruction/ maintenance manual of the product C16CP Panasonic
Go to page of 28
1 FP0 Series Programmable Controllers 07/2007.
Con t ro l F PWIN Pro PLC Progr a mm i ng So f t w a r e c on f orm i ng t o IEC61131-3 2 F P0 – S up e r Co m p a c t P L C In c r e d i b l y Sm a l l , A l on e or Ev e n a s Mu l t i p l e Comb i n e d Un i t s A control unit a mere 25mm* in width.
3 E i t h e r 10 Po i n t s or t h e M a x i m u m o f 128 Po i n t s Y ou S a v e Th i s Mu c h Sp a c e ! The expansion unit can be attached easily without any cables.
4 F P0 CP U U n i t s A R i c h L i n e -Up o f Bo t h S i ng l e a nd Comb i n e d Un i t s Con t ro l un i t s A maximum of 3 expansion units can be added to the control unit. ( Combining relay output types and transistor output types is also possible.
5 Relay output type F P0 Exp a ns i on U n i t s Choos e t h e Numb e r o f I / O Po i n t s t o Su i t t h e App l i c a t i on Digital I/O units Analogue I/O units Thermocouple and RTD units Network.
6 F P0 – I m pr e ss i v e C a p a b ili t i e s H i gh Sp e c i f i c a t i ons f or Bo t h Sp e e d a nd C a p a c i t y 0.9µ s per basic instruction.
7 F P0 – I m pr e ss i v e C a p a b ili t i e s F P0 F un c t i ons Equipped with 2-axis independent positioning and high-speed counter for support of PWM output. Pu l s e ou t pu t f un c t i on The unit comes equipped with 2 channels for the output of up to 10kHz pulses (5kHz during 2-channel output).
8 F P0 Co m m un i c a t i on S e r i a l In t e r f a c e s a nd Mod e m Comp a t i b l e Progr a m m i ng i n t e r f a c e T O O L por t ( a l so f or c o m m un i c a t i on ) In MEWTOCOL-COM Slave mode, this port of fers access to the entire FP0 memory area.
9 F P0 Co m m un i c a t i on E a s i e r M a i n t e n a n c e Th a n Ev e r B e f or e M a i n t e n a n c e s a v i ng ■ Overwrite function in RUN mode It is possible to overwrite a program while the FP0 is running, such as during program debugging and startup adjustments.
10 F P0 P R O F IB U S D P S l a v e or R e m o t e I/ O U n i t F or Cos t E f f e c t i v e Con t ro l o f D i s t r i bu t e d F i e l d D e v i c e The FP0 DPS2 can operate either as a DP Slave module or as a remote I/O system to which different decentralised inputs and outputs can be connected.
1 1 F P0 S - L I N K U n i t C on n e c t s D i r e c t l y t o t h e S -L IN K f or R e d u c e d W i r i ng Wire-saving The use of wires is greatly reduced and the number of connecting ter- minal blocks is minimised, resulting in large reduction in cost, as well as waste generated during wiring.
12 F P0 ME W N ET - F U n i t N e t wor k i ng Un i t s The FP0 can be used as a slave station for MEWNET -F (remote I/O system) by adding I/O link unit. MEWNET -F is a reduced-wiring, remote I/O system that connects PLCs located separately and I/O slave stations with 2-core cabling.
13 An a l ogu e S i gn a l Pro c e ss i ng F P0 An a l ogu e Un i t s ■ Multimode A/D, D/A conversion ■ High resolution: 12-bit V oltage, current and temperature selectable ■ 2 analogue inputs (.
14 An a l ogu e S i gn a l Pro c e ss i ng F P0 An a l ogu e Un i t s Item Description Rated operating voltage Operating voltage range 24VDC 21.6 to 26.
15 F P0 Th e rmo c oup l e Inpu t Exp a ns i on U n i t s En a b l e H i gh Pr e c i s i on T e mp e r a t ur e Con t ro l a t Low Cos t The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user-friendly temperature acquisition using standard thermocouples with high precision.
16 F P0 R T D Inpu t Exp a ns i on U n i t Us e r F r i e nd l y A c qu i s i t i on o f T e mp e r a t ur e s w i t h H i gh Pr e c i s i on Fea t ur e s FP0-RTD6 6 channels ■ The module can be easily installed in an existing system.
17 )TEM $ESCRIPTION 2ATEDOPERATINGV OLTAGE 6$# /PERATINGV OLTAGERANGE TO 6$# !LLOW ABLENOV OLTAGETIME POINTSPOINTSTYPE MSAT 6MSAT 6 POINTSPOINTS3,).
18 F P0 S e r i e s Sp e c i f i c a t i on T a b l e s *: Since the response time of X0 to X5 is very fast (for high-speed counter input), the FP0 happens to catch chattering noise as an input signal. T o prevent this, it is recommended that timer instruction should be included in the programme.
19 Con t ro l F P W I N Pro Progr a mm i ng A c c ord i ng t o t h e In t e rn a t i on a l S t a nd a rd IEC 61131-3 FPWIN Pro is the Panasonic programming software developed according to the international standard IEC 61 131-3 (for Windows 98, NT V4.
20 F P W e b- S e rv e r Progr a mm e / Op e r a t e t h e F P0 Us i ng a LAN or WAN N e t wor k The multifunctional FP W eb-Server provides users with the option of connecting the FP0 or any other FP Series PLC to the Internet/Intranet thus enabling bi-directional communication.
21 Con t ro l Co m m X , PC W A Y , O PC S e r v e r V i su a l i s a t i on So f t w a r e f or R e a dy M a d e or Cus t om i s e d So l u t i ons The connection in ActiveX technology . ■ Connects your Visual Basic application to Panasonic PLCs. ■ Gives you the possibility to easily develop highly customised control solutions.
22 Notes: • A power cable (order number AFP0581) is enclosed with the control unit and the relay output type expansion units (T ransistor output type upgrade units do not require a power cable). • T wo Phoenix terminals (9-pin) are needed with the relay output type terminal type.
23 F P0 An a l ogu e a nd N e t wor k i ng U n i t s Produ c t s a nd Ord e r Numb e rs Screw terminal type Order number: FP0-A80A 8 points Input 8 points Screw terminal type Order number: FP0-A21A 3 .
24 T e r m i n a l s c r e w d r i v e r N e c e ss ar y w h e n w i r i ng re l a y ou t pu t t yp e & t er m i n a l s (P ho e n i x ) . A tt a c h m e n t e x a m p l e W i r i ng t oo l s P a .
25 Progr a m m i ng T oo l s a nd Curr e n t Consu m p t i on L i s t Produ c t s a nd Ord e r Numb e rs Ver .2.6 Ver .2.6 © 1999-2006 Panasonic Electric Works Europe AG Made in Germany © 1999-2006 Panasonic Electric Works Europe AG Made in Germany Control FPWIN Pro English, German, French, Italian, Spanish, Japanese menu selectable.
26 F P0 S e r i e s Pow e r Supp l i e s ■ Small size: - FP0 power supply: 90 x 60 x 30.4mm - FP power supply: 1 15 x 75 x 42mm ■ Maximum output current: - FP0 power supply: 0.7A (24VDC) - FP power supply: 2.1A (24VDC) ■ Multiple voltage input: 85 to 265V AC ■ Optimal protection: overvoltage, overcurrent, overheating, etc.
27 F P0 Produ c t O v e r v i e w Ord e r Numb e rs Product Name Part Number 1. Control Units FP0-C10RS, 6 Inputs / 4 Outputs (p+n / Relay) FP0-C10RSA FP0-C10CRS, 6 Inputs / 4 Outputs (p+n / Relay), R.
16 G l ob a l N e t wor k S e r v i c e s G l ob a l N e t wor k S e r v i c e s G l ob a l N e t wor k S e r v i c e s C o p yr i g h t © 2 0 0 6 • Pr i n t e d i n G e r m a n y 4 09 3 e u e n 0 .
An important point after buying a device Panasonic C16CP (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Panasonic C16CP yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Panasonic C16CP - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Panasonic C16CP you will learn all the available features of the product, as well as information on its operation. The information that you get Panasonic C16CP will certainly help you make a decision on the purchase.
If you already are a holder of Panasonic C16CP, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Panasonic C16CP.
However, one of the most important roles played by the user manual is to help in solving problems with Panasonic C16CP. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Panasonic C16CP along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center