OMEGAnet® On-Line Service Internet e-mail www.omega.com info@omega.com
USA: One Omega Drive, Box 4047 ISO 9001 Stamford CT 06907-0047 Certified Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
USA and Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA® Canada: Customer Service: 1-800-622-2378 / 1-800-622-BEST® Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN® TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: [email protected]
Czech Rudé armády 1868, 733 01 Karviná 8 Republic Tel: +420 (0)69 6311899 FAX: +420 (0)69 6311114 Toll Free: 0800-1-66342 e-mail: czech@omega.com
France: 9, rue Denis Papin, 78190 Trappes Tel: +33 (0)130 621 400 FAX: +33 (0)130 699 120 Toll Free in France: 0800-4-06342 e-mail: [email protected]
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Austria: Tel:+ 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: [email protected]
United : One Omega Drive, River Bend Technology Centre Kingdom Northbank, Irlam, Manchester ISO 9002 M44 5BD United Kingdom Certified Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certi- fication of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certi- fication. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.
® · ®







Omega Engineering, the world's leading manufacturer of infrared temperature systems, presents the low cost OS950™ Series of hand held infrared thermometers. These dual-purpose systems function as both NIST trace- able temperature calibrators and thermal scanning devices. Make fast, accurate, and reliable temperature measure- ments using advanced non-contact IR technology.
Meet your company's product quality conformance needs with the OS950's patented Automatic Emissivity Compensation System (AECS). In this mode, the unit will provide precision temperature measurements of spot tar- gets, without knowing the target's emissivity value, and without errors caused by other sources of incident radiation. Since the OS950 is NIST traceable, it can function as a pri- mary temperature calibrator for other temperature measur- ing devices, serving your corporate quality instrument cali- bration programs. Operate the OS950 in SCAN mode, for thermal scanning measurements over a range of target temperatures. Thermal Scanning is very useful in many applications such as evaluating insulation, monitoring machinery, and inspecting electrical equipment. Or the OS950 may be operated in the MAX mode where the high- est temperature measured while monitoring is presented.
This manual provides complete instructions on how to oper- ate and use your OS950-- to provide fast, accurate, reliable temperature measurements for your application needs.
Designed for ease of use and measurement flexibility, the OS950 features:
OS950 -50 to 550°F (-45 to 287°C) Unit includes a 9 V DC Alkaline Battery and OS950 Instruction Manual. Also available with a Remote Sensor, RS232 Digital Output and an Analog Output.
OS953 0 to 1000°F (-18 to 538°C) Unit includes a 9 V DC Alkaline Battery and OS950 Instruction Manual. Also available with a Remote Sensor, RS232 Digital Output and an Analog Output.
OS955 0 to 1207°F (86 to 653°C) Unit includes a Remote Sensor, 9 V DC Alkaline Battery and OS950 Instruction Manual. Also available with an RS232 Digital Output and an Analog Output.




The instrument now reads in °C instead of °F. To return to the original setting, simply repeat the process.

ºF/ºC Switch MAX/SCAN Switch
The OS950 Models come from the factory operating in the MAX mode. To change to the SCAN mode perform the fol- lowing steps:
The unit will now operate in the SCAN mode. ON Î SCAN, 1 Î MAX.
2.4.1 General Operation CAUTION... SHOCK HAZARD DO NOT TOUCH THE INSTRUMENT TO ELECTRICAL CONDUCTORS*
The OS950™ measures temperature very quickly. To obtain an accurate measurement, it is only necessary to touch the surface for a fraction of a second.
For exact surface temperature measurements that are NIST traceable, use the following procedure:

To measure moving targets that are not possible to touch, use the following procedure:
** If the surface is metallic, be sure to mark it as described in the Measurement Tips section in Chapter Three.
When using the OS950™ to measure high temperature tar- gets, above 100 °F, quickly touch the target's surface -- one second is long enough to get an accurate reading.
Follow the procedures described above under 2.4.1 General Operation (see pg. 5). If the OS950 makes contact with a hot surface for an extended time (10 seconds or more) the target will conduct heat. Although this will not harm the unit, the indicated temperature may be a few degrees too high. Allow a few minutes between readings for the nosepiece to cool down and stabilize.
If the OS950 makes contact with a hot surface and an error message [HI] shows on the display remove the instrument from the object immediately.
Use this measurement mode when making contact with the target or when the target is large. The OS950 is a wide- angle thermal scanner with a fixed emissivity of 0.9. The target's temperature is continuously displayed and updated 10 times per second for as long as you hold the MEASURE button down.
The OS950 displays the average temperature of everything within the sensor's field of view measurement area. The size of the measuring area depends on the distance of the device from the target. The OS950 has a 1:1 field of view, which means that this unit will measure a 1"diameter target area when the device is 1" from the target.
For continuous temperature measurement of a target or for temperature measurement at a distance, use the following procedure.

Use this measurement mode for thermal scanning of a tar- get or when measuring targets located at a distance. The OS950 is a wide-angle thermal scanner with a fixed emis- sivity of 0.9. The target's temperature is continuously dis- played and updated 10 times per second for as long as you hold the MEASURE button down.
The OS950 displays the average temperature of everything within the sensor's field of view measurement area. The size of the measuring area depends on the distance of the device from the target. The OS950 has a 1:1 field of view, which
means that this unit will measure a 1"diameter target area when the device is 1" from the target.
For continuous temperature measurement of a target or for temperature measurement at a distance, use the following procedure.
When performing a continuous thermal scan of a target, or measuring a target located at a distance, proper target alignment will help assure accurate results. Since the OS950's sensor measurement area is fixed at a field of view of 1 to 1, it is important to properly determine the best measuring distance from the target, to optimize the reading. A field of view of 1 to 1 means that the OS950 viewing area is 1" diameter for 1" distance from target. Optimize optical alignment, so that the OS950 views only the target and does not overlap the measurement area. See Figure below for examples of proper optical alignment.


In general, infrared thermometers can easily measure non- metallic surfaces because they emit most of their potential heat. Metallic surfaces, on the other hand, are poor emit- ters and require special treatment before infrared ther- mometers can accurately measure their temperature. Fortunately, that special treatment is simple and can be easily accomplished by marking the metallic surface you wish to measure with a non-metallic substance such as a solid paint marker. Other substances such as grease, oil, or tape may also be used. It is only necessary to mark an area slightly larger that the OS950 nosepiece, when operat- ing in AECS mode. When operating in MAX or SCAN modes, mark the appropriate target area for the measuring distance from the target, based on a 1 to 1 Field of View.
If you look at the OS950's nosepiece, you will see that it is really a small reflective cup with the sensor's window at its base. When the OS950's nosepiece touches the surface of an object, that reflective cup automatically controls what the sensor sees by eliminating variables such as target emis- sivity and extraneous radiation. Patented by Exergen as the Automatic Emissivity Compensation System (AECS), this unique design ensures accurate readings every time. To optimize results, make sure that the nosepiece is flush with the target when possible, so that the reflective cone can complete trap out any light or incident radiation from the environment.
Although transparent materials pass visible light, many visi- bly transparent materials are opaque in the infrared and can be directly measured by the OS950.
To test for infrared transparency, touch the OS950 to the target's surface and pass a heat source such as your hand or a penlight through the sensor's field of view on the other side of the material. If the OS950 responds to the heat source, the material is transparent in the infrared, and requires marking the surface for proper measurement. Mark the surface with an opaque non-metallic coating, such as paint or grease.
Alternatively, place a shiny metallic object, such as alu- minum foil, behind the transparent material. The shiny metal will reflect the target's heat back to the OS950.
Wet or icy surfaces may interfere with the OS950's read- ings. Water and other liquids are good targets, but evapo- ration lowers their surface temperatures.
Frost forms on a surface at the freezing point of water. Frozen foods or similar targets will form frost unless the environment is controlled. If frost forms, the OS950 will measure the temperature of the frost instead of the object's temperature.
Melting ice will read slightly higher than 32 °F (0°C) because the instrument actually measures the air condens- ing on the ice, a reaction that generates a small amount of

heat. As long as the ice is not melting, the OS950 will accurately read its temperature.
To make an accurate target measurement, remove any ice or moisture before measuring.
The high-performance OS950 is a rugged and durable instrument, designed for long term performance reliability.
Open the instrument's cover to access the battery by loos- ening the screw on the back of the instrument. Remove the old battery and replace it with one fresh, 9 V alkaline bat- tery. Align the battery contacts as indicated on the case.
The only maintenance required involves keeping the sensor window clean. This window, located at the base of the nosepiece's reflective cup, is made of a special crystal that passes infrared heat. Dirt, greasy films, or moisture on the window will interfere with the passage of infrared heat and affect the accuracy of the instrument.
If necessary, clean the sensor window and reflective cup with a cotton swab dipped in alcohol. Periodic cleaning is a good practice.
When not in use, store the OS950 in a container, to protect the unit from dirt and dust. Do not store the unit in areas of extreme heat, cold, or humidity. If not using the OS950 for a long period, remove the battery from the unit.
The OS950 is factory calibrated under high quality stan- dards. Because there are no mechanical adjustments, the instrument is able to maintain its calibration through vibra- tion and normal use. No field calibration is necessary.
The high-performance OS950™ continuously monitors its ability to produce accurate temperature readings. If either the target's temperature or the unit's ambient temperature exceeds the operational limits, the display will default to an error message.
The battery voltage is also monitored. A low battery is indi- cated by a separate error code. The unit will continue to operate as long as accuracy can be assured. If the battery drops below 5.7 volts, the battery is considered "dead" and the display defaults to [ ].


If the [E-##] or [Err] error messages are displayed, the unit will not function and must be returned to the factory for repair. (See section on Warranty for return instruction).
The following charts summarize the fault condition, and the associated indication.
Model OS951 [LO] Target < -50 °F (-45 °C)
Model OS953 [LO] Target
Internal fault Repeat measurement, if error remains, contact Omega

If you experience measurement problems, review the fol- lowing troubleshooting steps:
Is the sensor window clean? Clean the sensor window and reflective cup and repeat the measurement.
Is the target's surface non-metallic? Coat metallic surfaces with a non-metallic finish and repeat the measurement.
Is the target's surface transparent? Coat transparent surfaces with an opaque non-metallic fin- ish and repeat the measurement.
Alternatively, put a shiny metallic surface such as aluminum foil behind the transparent target and repeat the measure- ment.
Was the instrument's nosepiece in contact with the surface? Touch the nosepiece flush to the target's surface and repeat the measurement.
If after applying all of the above solutions, the instrument's accuracy is still in question, contact Omega for further help.
OS951 -50 to 550°F (-45 to 287°C) OS953 0 to 1000°C (-18 to 538°C) OS955 186 to 1207°F (86 to 653°C) OS956 186 to 1600°F (86 to 871°C)
OS951 ± 1% of reading OS953 ±3% of reading OS955 ±3% of reading OS956 ±3% of reading
±1% of max. difference between target temperature and instrument temperature when touching, for emissivity of 0.8 to 1.0
Approx. 1/4" (6.4 mm) Repeatability ± 0.1 °F/°C
Display Resolution
0.1 °F or 0.1 °C
In AECS Mode

Measurement Response Time
Approximately 0.1 seconds
1:1 0.63" (15.9 mm) Diameter Spot Area in AECS Mode
2 to 20 microns
Battery Life
5000 readings (10 seconds each)
*Extended storage at temperature extremes will reduce bat- tery life.
10 times/second · One 9 volt



WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product.
FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2001 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

for Process Measurement and Control?
OMEGA…Of Course! Shop online at www.omega.com
TEMPERATURE Thermocouple, RTD & Thermistor Probes,
Connectors, Panels & Assemblies
Calibrators & Ice Point References
Recorders, Controllers & Process Monitors
PRESSURE, STRAIN AND FORCE Transducers & Strain Gages
Load Cells & Pressure Gages
Instrumentation & Accessories
FLOW/LEVEL Rotameters, Gas Mass Flowmeters & Flow
Air Velocity Indicators
Totalizers & Batch Controllers
pH/CONDUCTIVITY pH Electrodes, Testers & Accessories
Controllers, Calibrators, Simulators & Pumps
Industrial pH & Conductivity Equipment
DATA ACQUISITION Data Acquisition & Engineering Software
Communications-Based Acquisition Systems
Plug-in Cards for Apple, IBM & Compatibles
Recorders, Printers & Plotters
HEATERS Heating Cable
Cartridge & Strip Heaters
Immersion & Band Heaters
ENVIRONMENTAL MONITORING AND CONTROL Metering & Control Instrumentation
Pumps & Tubing
Air, Soil & Water Monitors
Industrial Water & Wastewater Treatment
pH, CoOnductivity & Dissolved Oxygen Instruments
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.