OS643 Infrared Thermometer

OMEGAnetSM On-Line Service
Internet e-mail info@omega.com
Servicing North America: USA: ISO 9001 Certified Canada: One Omega Drive, Box 4047 976 Bergar Stamford, CT 06907-0047 Laval (Quebec) H7L5A1 Tel: (203) 359-1660 Tel: (514) 856-6928 FAX: (203)359-7700 FAX: (514) 856-6886 e-mail: info@omega.com e-mail: info@omega.com
For immediate technical or application assistance: USA and Canada: Mexico and Latin America: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM Tel: (95) 800-TC-OMEGASM
Customer Service: 1-800-622-2378 / 1-800-622-BESTSM FAX: (95) 203-359-7807 Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSM En Español: (203) 359-7803 TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA e-mail: espanol@omega.com
Servicing Europe:
Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 06 0993344 e-mail: nl@omega.com
France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33)130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com
United Kingdom: ISO 9002 Certified One Omega Drive Riverbend Technology Centre Northbank, Irlam, Manchester, M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622
Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0800 82 66342 e-mail: germany@omega.com
Czech Republic: ul. Rude armady 1868, 733 01 Karvina- Hranice, Czech Repubic Tel: 420 (69) 6311627 FAX: 420 (69) 6311114 e-mail: czech@omega.com

INTRODUCTION This instrument is a portable easy use 3½ digit, compact-sized digital infrared thermometer simple one hand operation. Meter with Backlit LCD display, Auto- hold function and auto power off (15 seconds approx.) feature after releasing MEAS button to extend battery life and with analog signal output function.
SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the thermometer.
The symbol on the instrument indicates that the operator must refer to an explanation in this manual.


SPECIFICATIONS GENERAL Display: 3½ digit liquid crystal display (LCD) with maximum reading of 1999. Overrange: (OL) or (-OL) is displayed. Low battery indication: the " " is displayed when the battery voltage drops below the operating level. Measurement rate: 2.5 times per second, nominal. Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% relative
removed from meter. Auto power off: 15 seconds approx. Standby consume current:

ELECTRICAL Temperature Range: 0°F to 500°F / -20°C to 260°C. Display Resolution: 1°F / 1°C. Accuracy: ±3% of reading or ±6°F/3°C, whichever is greater @ 64.4 to 82.4°F
(@ 18 to 28°C) ambient operating temperature. Temperature Coefficient: ±0.2% of reading or ±0.36°F/0.2°C, whichever is
greater, change in accuracy per °F/°C change in ambient operating tempera- ture above 82.4°F/28°C or below 64.4°F/18°C. Response Time: 1 second. Spectral Response: 6 to 14µm nominal. Emissivity: Pre-set 0.95. Analog Output: 1mV/°F(°C). Detection Element: Thermopile. Optical Lens: Fresnal Lens. Field of View: 65mmØ at 1000mm.


Display Back-Light Button Release MEAS button then press " " button to toggle between turn on and turn off the Back-Light. When releasing MEAS button Back-Light will turn off auto- matically after 15 seconds to extend battery life.
MEAS (MEASURE) Button Depress MEAS button to turn on the meter for measuring temperature. Releasing MEAS button to stop measuring temperature and automatically hold the display reading, the meter turns off automatically after 15 seconds.

OPERATION 1. When the power is off, pressing the MEAS button turns on the power. 2. Use " " button to select turn on or turn off the display Back-Light. 3. Use "°F/°C" button to select °F or °C the Temperature Range. 4. Point the lens at the object whose temperature is to be measured. 5. Press the MEAS button. Measurement is performed as long as the MEAS button is kept pressed. 6. Referring to the spot size figure, aim the laser beam at the object whose temperature is to be measured. NOTE: Although the field of measurement (or Field of View) and the spot almost
coincide, actually the field of measurement corresponds to the diameter for 90% optical response. The object whose temperature is to be measured needs to be larger than the measurement diameter (spot of size) by an adequate margin at least 1.5 to 2 times larger. 7. Read the diaplay.

MEASUREMENT CONSIDERATIONS 1. Theory of Measurement Every object emits infrared energy in accordance with its temperature. By measuring the amount of this radiant energy, it is possible to determine the temperature of the emitting object. 2. About Infrared Infrared radiation is a form of light (electromagnectic radiation), and has the property that it, passes easily through air while it is easily absorbed by solid matter. With an emission thermometer which operates by detecting infrared radiation accurate measurement is possible, irrespective of the air tempera- ture or the measurement distance. 3. Emission Thermometer Structure Infrared radiation which has been emitted from the object is focused upon an infrared radiation sensor, via an optical system which includes a lens is transparent to infrared rediation, an 5.3µm cut off filter. The output signal from the infrared radiation sensor is input to an electronic circuit along with the output signal from a standard tempeature sensor (Thermopile).

4. Emissivity All objects emit invisible infrared energy. The amount of energy emitted is proportional to the object's temperature and its ability to emit IR energy. This ability, called emissivity, is based upon the material that the object is made of and its surface finish. Emissivity values range from 0.10 for a very reflective object to 1.00 for a black body. Factory set emissivity value of 0.95, which cover 90% of typical applications. 5. If the surface to the measured is covered by frost or other material, clean it to expose the surface. 6. If the surface to be measured is highly reflective, apply masking tape or matt finish black paint to the surface. 7. If the meter seems to be giving incorrect readings check the front cone. There may be condensation or debris obstructing the sensor; clean per instructions in the maintenance section.

MAINTENANCE Battery Replacement Power is supplied by four 1.5V (AAA size) batteries. The " " appears on the LCD display when replacement is needed.To replace the batteries, remove the screw from the back of the meter and lift off the battery cover case. Remove the batteries from battery contacts.
Cleaning Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents.

Substance Thermal Substance Thermal emissivity emissivity Asphalt 0.90 to 0.98 Cloth (black) 0.98 Concrete 0.94 Human skin 0.98 Cement 0.96 Lather 0.75 to 0.80 Sand 0.90 Charcoal (powder) 0.96 Earth 0.92 to 0.96 Lacquer 0.80 to 0.95 Water 0.92 to 0.96 Lacquer (matt) 0.97 Ice 0.96 to 0.98 Rubber (black) 0.94 Snow 0.83 Plastic 0.85 to 0.95 Glass 0.90 to 0.95 Timber 0.90 Ceramic 0.90 to 0.94 Paper 0.70 to 0.94 Marble 0.94 chromium oxides 0.81 Plaster 0.80 to 0.90 Copper oxides 0.78 Mortar 0.89 to 0.91 lron oxides 0.78 to 0.82 Brick (red) 0.93 to 0.96 Textiles 0.90

WARRANTY OMEGA warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product. If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA's Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components which wear or which are damaged by misuse are not warranted. This includes contact points, fuses, and triacs.
OMEGA is glad to offer suggestions on the of use of its various products. Nevertheless, OMEGA only warrants that the parts manufactured by it will be as specified and free of defects
OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED.
LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order, whether based on contract warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.
Every precaution for accuracy has been taken in the preparation of this manual; however, OMEGA ENGINEERING, INC. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in the manual.
SPECIAL CONDITION: Should this equipment be used in or with any nuclear installation or activity, purchaser will indemnity OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the equipment in such a manner.

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient connected application.
RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA'S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.
FOR WARRANTY RETURNS, please have the following
FOR NON-WARRANTY REPAIRS, consult OMEGA for
information available BEFORE contacting OMEGA: 1. P.O. number under which the product was PURCHASED. 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product.
current repair charges. Have the following information available BEFORE contacting OMEGA: 1. P.O. number to cover the COST of the repair. 2. Model and serial number of product , and 3. Repair instructions and/or specific problems relative to the product.
OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 1999 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable from, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.

Process Measurement and Control?
OMEGA...Of Course!
HEATERS þ Heating Cable þ Cartridge & Strip Heaters þ Immersion & Band Heaters þ Flexible Heaters þ Laboratory Heaters
TEMPERATURE þ Thermocouple, RTD & Thermistor
pH/CONDUCTIVITY þ pH Electrodes, Testers &
Probes, Connectors, Panels & Assemblies þ Wire: Thermocouple, RTD &
Accessories þ Benchtop/Laboratory Meters þ Controllers, Calibrators,
Thermistor þ Calibrators & Ice Point References þ Recorders, Controllers & Process
Simulators & Pumps þ Industrial pH & Conductivity
PRESSURE/STRAIN AND FORCE þ Transducers & Strain Gauges þ Load Cells & Pressure Gauges þ Displacement Transducers þ Instrumentation & Accessories
Monitors þ Infrared Pyrometers
DATA ACQUISITION þ Data Acquisition & Engineering
ENVIRONMENTAL MONITORING AND CONTROL þ Metering & Control Instrumentation þ Refractometers þ Pumps & Tubing þ Air, Soil & Water Monitors þ Industrial Water & Wastewater
FLOW/LEVEL þ Rotameters, Gas Mass
Acquisition Systems þ Plug-in Cards for Apple, IBM
Flowmeters & Flow Computers þ Air Velocity Indicators þ Turbine/Paddlewheel Systems þ Totalizers & Batch Controllers
& Compatibles þ Datalogging Systems þ Recorders, Printers & Plotters
Treatment þ pH, Conductivity & Dissolved
Equipment · Software þ Communications-Based · Oxygen Instruments
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.