tion manual carefully. After reading, store the manual together with the warranty card in a safe, easily accessible place. ■ This product is the Waterproof Lens Port (PPO-E03) designed exclusively for use with the PT-E series of
waterproof case. ■ Underwater manual focus (MF) is possible by attaching the provided gear to the MF ring on the camera
lens. ■ Note that this will restrict the rotation range of the MF ring to within 180°.
reproduction is strictly prohibited. ■ Olympus shall not be responsible for damages, loss of profit or any claims by third parties in case of any
damage occurring from incorrect use of this product.
product with care. ■ This product must always be used in combination with an applicable lens. Do not combine this product
with an inapplicable lens. ■ To ensure correct and safe use of this product, always use it as described in this instruction manual.
This instruction manual uses pictographs to show how to use the product correctly and how to prevent danger to the user and other persons as well as damage to property. These pictographs and their meanings are shown below.


PPO-E03 main body Silicon O-ring (POL-E101) Front cap Rear cap MF Gear Grease for silicone O-ring Pick for O-ring removal

This section describes how to mount this product on the PT-E series case. Before mounting, check that no foreign matter is attached to the O-rings, the port mount thread on the PT-E series case, or the O- ring contact surfaces. Apply a thin layer of the provided silicone O-ring grease.
Align the threaded section of the PPO-E03 with the port mount thread on the PT-E series case. Hold the PT-E series case firmly with one hand, hold the main body of the PPO-E03 with your other
hand and screw it into the PT-E series by turning the PPO-E03 clockwise. Resistance increases as the PPO-E03 is screwed in more deeply. However, be sure to screw it in all the
way until there is no gap visible below the threaded section of the PPO-E03.



If any water is on the product, wipe it completely away and
Holding the PT-E series case firmly with one hand, loosen the
PPO-E03 by turning it about 90 degrees counterclockwise. If the PPO-E03 is attached too tightly to turn, wrap it with a piece of rubber or similar non-slip material.
After loosening the PPO-E03, point its lens downward and
turn it further counterclockwise until it is separated from the PT-E series case. Be careful not to drop the PPO-E03 or PT-E series case.
ter on the lens or camera. If this happens, wipe the water off the lens and camera with a dry cloth. ・Make sure that the port is completely dry before dismounting.

To control the camera lens’s manual focus (MF) operation, the provided gear must be attached to the MF ring on the lens. * Note that this will restrict the rotation range of the MF ring to within 180°.
Confirm the position of the gear’s lock dial and hinge. Turn
the lock dial counterclockwise to release the lock and open the gear.
Open the gear all the way, place it on the lens and adjust the
rotation direction of the gear. At this time, bring the gear to the left of the hinge as shown in the illustration.
Align the hinge with the index.
Set the front-rear direction of the gear by aligning the edge
of the hinge with the end of the rubber section on the lens’ MF ring.
After positioning the gear, place it against the lens’ MF ring,
while taking care not to displace it. Turn the gear’s lock dial all the way clockwise to lock it so that the gear will not open. Push the gear with a finger to place the gear against the lens.
Turn the lock dial to lock the zoom gear.
operation cannot be controlled smoothly. Be sure to attach the gear correctly.

After attaching the gear to the camera’s lens, insert the camera and lens into the PT-E series case on which the PPO-E03 is mounted.
Screw the camera table provided with the PT-E
Remove the eyecup from the camera’s viewfind-
series case firmly into the bottom of the cam- era.
er. If a lens cap or filter is attached to the lens or the strap is attached to the camera, remove them as well.
Pull out the zoom/MF dial further.
Camera table lock lever
Pull up the power switch dial, mode dial knob
Confirm that the camera’s power switch is OFF.
and zoom/MF dial on the PT-E series case, and turn the case’s camera table lock lever counterclockwise to release the lock. Attach the flash hot shoe cable as instructed in the PT-E series case manual.
While pulling out the zoom/MF dial on the PT-E series case , slide the camera table with cam- era attached as far as it will go into the camera table mount on the inner side of the case’s front lid.

After inserting the camera, turn the PT-E series
Push in the PT-E series case’s power switch
case’s camera table lock lever all the way clock- wise to lock the camera table. Then, push in the zoom/MF dial on the PT-E series case and engage it with the gear attached to the lens. Turn the zoom/MF dial to confirm that it can con- trol the lens’s MF operation.
dial and mode dial knob. Turn the power switch dial and mode dial knob and confirm that they can control the camera power ON-OFF and mode switching. Connect the hot shoe mount section of the hot shoe cable that has been connected to the PT-E series case to the hot shoe of the camera.
Attach the rear lid of the PT-E series case and
lock the four buckles (two diagonally located buckles first, and then the other two diagonally located buckles). Underwater shooting is now possible.

For safe use of this product, always perform maintenance after each diving session. For details, refer to “Handling After Shooting” and “Maintaining the Waterproof Function” in the PT-E series case instruction manual. Apply the same procedures to this product.


era and lens, then re-seal the empty case and immerse it in tap water to remove any salt as soon as possible.
case is completely dry, dismount this product from the case.
Remove sand and dust from the O-rings.
using the provided pick for removing O-rings. Take care not to damage the O-rings.
Pinch each O-ring between your fingers and lightly rub the entire circumference to check for foreign matter, scratches and cracks.


If any foreign matter is attached to the
After removing foreign matter, apply the
O-ring grooves, remove it using a clean, lint-free cloth or cotton swab. Also remove any foreign matter from the O-ring contact surfaces and from the port mount thread on the PT-E series case.
provided grease to the O-rings and fit them into the O-ring grooves. To apply grease to each O-ring, squeeze a drop of grease about the size of a grain onto your finger and lightly rub the entire circumference of the O-ring to spread the grease thinly and evenly.

Applicable case : PT-E series Applicable lens : ZUIKO DIGITAL ED 50mm F2.0 Macro Main materials Main body : Aluminum. Lens window : Chemically reinforced glass. O-rings : Silicon rubber. MF gear : Polycarbonate resin. Front cap : NBR rubber. Rear cap : Polyethylene resin. Withstanding pressure : Water depth of 60 m (200 ft) Dimensions : Max. diameter 108 mm x Depth 87 mm Weight : 420 g (excluding the conversion lens)
This product uses the following consumable items.

Description O-ring for use with the PT-E series case.
Shinjuku Monolith, 3-1 Nishi Shinjuku 2-chome, Shinjuku-ku, Tokyo, Japan
Tel: +49 40-23 77 3-0 Fax: +49 40-23 07 61 Goods delivery : Bredowstrasse 20, 22113 Hamburg, Germany Letters : Postfach 10 49 08, 20034 Hamburg, Germany
European Technical Customer Support: Please visit our homepage http://www.olympus-europa.com or call our TOLL FREE NUMBER* : 00800 - 67 10 83 00
Two Corporate Center Drive, Po Box 9058, Melville, NY 11747-9058, U.S.A. Tel. 631-844-5000
Technical Support (USA) 24/7 online automated help: http://www.olympusamerica.com/support Phone customer support: Tel. 1-888-553-4448 (Toll-free)
for Austria, Belgium, Denmark, Finland, France, Germany, Italy, Luxemburg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, United Kingdom *Please note that some (mobile) phone services/ provider do not permit access or request an additional prefix to +800 numbers.
Our phone customer support is available from 8 am to 10 pm (Monday to Friday) ET E-Mail: distec@olympus.com Olympus software updates can be obtained at: http://www.olympus.com/digital/
For all not listed European Countries and in case that you can’t get connected to the above mentioned number please make use of the following CHARGED NUMBERS: +49 180 5 - 67 10 83 or +49 40 - 237 73 899 Our Technical Customer Support is available from 9am to 6pm MET (Monday to Friday)
© 2005 OLYMPUS IMAGING CORP.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.