Page 1 of the Norcold 442 user manual — FOR YOUR SAFETY If you smell gas:
Page 1 · click to enlarge
Page 1
Norcold 442 — Cover Page diagram (page 1)
Fig. 1 · Cover Page
Norcold 442 — Cover Page diagram (page 1)
Fig. 2 · Cover Page
Norcold 442 — Cover Page diagram (page 1)
Fig. 3 · Cover Page

INSTALLATION AND OPERATING

INSTRUCTIONS

442 443 452 453 482 483 462 463

Contents

Safety Precautions 2

Extended Service Protection Plan 4

Ventilation Requirements 5

Installation Instructions 8

Decorative Door Panel Installation 11

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquid in the vi- cinity of this or any other appliance.

Reversing Door Swing 11

Lighting and Start-Up Instructions 14

Operating and User Instructions 15

Refrigerator Maintenance 17

FOR YOUR SAFETY If you smell gas:

Trouble Shooting 19

Failure of Refrigerator 20

1. Open windows 2. Do not touch any electrical switches 3. Extinguish any open flame 4. Immediately call your gas supplier

Replacement Parts 20

Wiring Diagrams 21

Warranty 23

These refrigerators are designed to operate on the following energy sources:

LP GAS OPERATION - 11.0 inches Propane & 12 volt DC control voltage (15.4 volts max., 10.5 volts min.). AC OPERATION - 120 volts AC (132 volts max., 108 volts min.) and 12 volt DC control voltage. DC OPERATION - [3-WAY MODELS] 12 volts DC (15.4 volts max., 11.5 volts min.). Operation where these specifications are exceeded will void the refrigerator warranty. MODEL NO SERIAL NO The refrigerator’s model number and serial number are on the serial plate located in the refrigerator.

Part No.: 618484B (95-09)

Page 2 of the Norcold 442 user manual — Exhaust Gases
Page 2 · click to enlarge
Page 2

Safety Precautions

Read this manual and become thoroughly acquainted with it before installing or starting the refrigerator. The following safety precautions and recommendations contained herein are for your protection.

Improper installation, adjustment, or operation can cause injury or property damage. The safety symbols used in this manual contain Safety Alert information. Understand their meanings and be safety conscious.

DANGER

A SITUATION WHICH, IF NOT AVOIDED, WILL RE- SULT IN DEATH OR SERIOUS INJURY.

WARNING

A SITUATION WHICH, IF NOT AVOIDED, COULD RE- SULT IN DEATH OR SERIOUS INJURY.

CAUTION

A SITUATION WHICH, IF NOT AVOIDED, MAY RE- SULT IN MINOR OR MODERATE INJURY.

General

  • Keep the unit and surrounding area clean. Never use the area behind refrigerator for storage; in particular, storing flammable materials (oily rags, paper, aerosol cans, and chemicals.). Stored materials not only present a safety hazard but could block the ventilation to the system.
  • Provide appropriate fire extinguishers installed in convenient locations. Consult your local fire department for the correct type to use. Do not use foam on electrical fires. Use extinguisher rated by NFPA.
  • Make sure all fasteners, supports, seals, electrical covers are secure.

LP Gas System

  • LP gas is highly flammable. Gas connections must be leak tight. Do not smoke, create sparks or use an open flame when checking gas connections. Do not ignore the "rotten egg" smell of gas fumes.
  • Protect all gas lines from physical damage, vibration, or excessive heat.
  • Insure that the supply gas pressure is within the tolerance specified on the front cover of this manual. The gas controls are designed for safety. Never tamper with the adjustment or function of the controls other than as directed by the Lighting and Shutdown Instructions. All repairs must be done by a qualified service person.

Exhaust Gases

  • Proper ventilation to remove exhaust gases is extremely important. These gases, generated in the GAS mode at the rear of the refrigerator, replace the oxygen in the air and in extreme cases can produce dangerous levels of carbon monoxide. This manual contains installation instructions to safely remove the exhaust gases and seal the zone from the living area. The installation instructions are certified by American Gas Association and Canadian Gas Association and must be followed.
  • Check the burner for proper flame characteristics at the initial start-up and at least once every year. The information for this check is located in this manual and must be performed by a qualified service person.
Page 3 of the Norcold 442 user manual — Handling the Refrigerator
Page 3 · click to enlarge
Page 3

Safety Precautions - continued

Electrical Circuits - AC and DC

  • The 120 volt AC circuit must be properly grounded. Never cut or remove the round grounding prong from the refrigerator’s AC cord. Do not use a two-prong adapter. Do not use an extension cord to connect to the approved AC receptacle.
  • Protect all wiring from physical damage, vibration, or excessive heat.
  • Always disconnect both AC and DC sources of power when working on either circuit (only a qualified service person).
  • Insure all terminating connections are clean and tight to prevent arcing or overheating.
  • Never allow Leak Detecting fluids or any other liquids to spill on electrical connections. Many liquids are electrically conductive and could cause serious arcing damage and, in some case, fires.

Refrigerant System

  • Never physically bend, drop, drill, weld, or hammer the refrigerant system. Doing so could cause the system to rupture and release dangerous chemicals which can cause severe burns to the eyes or skin. If ignited, these chemicals will burn with intense flame. A leaking system can release certain chromium components which, if inhaled, can cause cancer.
  • Never apply direct heat in excess of 240° F to the refrigerant system. Because the refrigerant is hermetically sealed under pressure, a temperature sensitive safety device opens to protect the system from erupting under excessive pressure. However, the expelled refrigerant could ignite and burn if an ignition source were near.
  • Never attempt to repair or recharge the refrigerant system. If defective, it must be replaced.

Child Entrapment

  • Never install door locks or other restraints which could entrap small children within the refrigerator. The Travel Latch system must not be modified.

Handling the Refrigerator

  • Never lift the refrigerator without assistance. Protect yourself from body strain.
  • Avoid hot surfaces at the rear of the refrigerator when operating. The absorption type refrigerator produces several hot areas at the rear of the unit. This is true whether in GAS or ELECTRIC mode.
  • Take care to avoid brushing against the irregular shapes and sheet metal parts at the rear of the refrigerator. Cuts or abrasions could result.
Page 4 of the Norcold 442 user manual — General Instructions - All Models
Page 4 · click to enlarge
Page 4

E.S.P.

EXTENDED COOLING UNIT SERVICE PROTECTION PLAN

An additional four year Service Contract is now available to original purchasers of Norcold refrig- erators. For only $40.00 you get:

the original purchaser. The contract provides re- placement of a defective cooling unit only for this refrigerator (freight, parts, and labor) for an addi- tional period of four years after expiration of the original Limited Warranty. The refrigerator must be delivered to Norcold Service Center together with the Norcold E.S.P. card showing E.S.P. coverage. An E.S.P. card will be mailed to the original pur- chaser upon receipt of a completed Service Con- tract Application form and a check covering the E.S.P. charge. E.S.P. coverage is non-transfer- able and non-refundable.

* Four extra years protection against cooling unit failure.

* Automatic replacement of defective cooling unit.

* Pre-paid freight from your dealer to Norcold and return.

* Labor free of charge.

To register your refrigerator, fill out the warranty Service Contract Application - i.e.: Tear Sheet Form in yellow envelope or include the following information (Please Print Clearly):

The E.S.P. (Extended Service Protection) plan can be obtained by mailing your check for $40.00*, U.S. funds to:

1. Owner’s name and address. 2. Refrigerator model number. 3. Refrigerator serial number. 4. Date of purchase. 5. Refrigerator proof of purchase 6. Check for $40.00* (payable to Norcold).

NORCOLD P O BOX 4248 SIDNEY OH 45365-4248

If mailing in Canada:

Applications will be accepted only if they are mailed within ninety (90) days after date of purchase.

GREG LUND PRODUCTS LTD P O BOX 760 OAKVILLE ONTARIO CANADA L6J 5C4 E.S.P. is a service contract between Norcold and

*Ohio residents, add $2.60 sales tax.

General Instructions - All Models

Keep the refrigerator and the surrounding area clear and free of combustible materials, gasoline, and other flammable materials.

The refrigerators described in this manual are de- signed for built-in installations and require cut out di- mensions as indicated on page .

The refrigerators must be placed on a solid and level floor away from heat generating sources. The floor must be strong enough to support the combined weight of the refrigerator and its food load.

use as a Free-Standing refrigerator. The refrigerator must be used in the manner for which it was designed. Refer to this manual for installation, operating proce- dures, and the refrigerator intended use. This appliance is equipped for LP gas and cannot be converted to any other fu- els (Natural Gas, Butane, etc.).

Never install the refrigerator directly on carpeting. To protect carpeting, the refrigerator must be placed on a metal or wood panel extending at least the full width and depth of the refrigerator.

Page 5 of the Norcold 442 user manual — Certified Vent Kits
Page 5 · click to enlarge
Page 5

VENTILATION REQUIREMENTS

WARNING: Carbon Monoxide can cause nausea, fainting, or death. Inadequate ven- tilation or partial blockage of the refrigera- tor’s flue can result in increased carbon monoxide emissions when operating in the gas mode. To prevent the emission of lev- els of carbon monoxide, installation must assure complete isolation of the living space of the R.V. from the refrigerator’s combustion system. Follow Norcold’s Ven- tilation and Installation recommendations explicity.

The vents for these refrigerators are certified by A.G.A. and CGA and must be installed as directed by this manual without modification. Any deviation or substitution:

* Can result in carbon monoxide levels in the living space of the vehicle. * Will void the agencies’ certification. * Will void the refrigerator warranty. * Will effect refrigerator performance. The intake vent (lower) also serves as a access (service entrance) door. The bottom of the intake vent opening must be flush with the surface on which the refrigerator is mounted. This configuration allows any leaking propane to ventilate to the outside.

Venting is required in an R.V. refrigerator installa- tion to remove the products of combustion, to isolate the living space of the vehicle from the combustion system of the refrigerator, to remove the excess heat from the generator area of the refrigerator’s cooling system, and to remove the heat that is extracted from the refrigerator cabinet.

A.G.A. And CGA certification permits installing the refrigerator with zero (0) inches minimum clearance between the refrigerator and any adjacent walls. This certification does not specify any maximum clear- ance. However, to insure adequate air flow across the cooling system, the clearance must be mini- mized. The combination of the two vents and the minimum clearances provide the necessary air flow through the creation of a natural draft, or "chimney effect" across the cooling system.

Certified installation requires that one intake (lower) and one exhaust (upper) be used. For the models 6052, 6053, 652, and 653, the installer has the op- tion of exhausting through the roof or through an up- per side wall vent. Whether roof or side wall exhaust venting, the specified vent kit must be installed as directed by this manual. To insure adequate refrig- erator performance, a continuous air flow is required across the refrigerator’s cooling system. The air passage from the intake vent to the refrigera- tor coils and from the refrigerator coils through the exhaust vent must be unobstructed.

Certified Vent Kits

Kit NumberCertified Lower Vent DoorCertified Roof JackModels 2 & 3615998 616009 616010 617778615791All Models Kit NumberCertified Lower Vent DoorCertified Upper Side ExhaustModels 4615998 616009 616010 617778617485442. 443 452, 453 ONLY

TABLE 1 DIMENSIONS (INCHES) for Vent Kits 2, 3, and 4

Cut - Out Dimension (inches) Roof JackLower Intake VentApproved Models Part No.TypeLengthWidthHeightWidthRadius 617778Plastic- -- -13 3/421 1/2- -All Models 616010Sq. Corner- -- -13 3/421 3/4- -All Models 616009Rad. corner- -- -13 3/421 7/83 1/4All Models 615998Rad. Corner- -- -13 3/421 7/83 1/4All Models Upper Side vent----7 1/418--6052, 6053 652, 653 615791Roof Jack245 1/4- -- -- -All Models
Page 6 of the Norcold 442 user manual — Alternate Construction Requirements Figure 3
Page 6 · click to enlarge
Page 6
Norcold 442 — Ventilation Requirement diagram (page 6)
Fig. 4 · Ventilation Requirement

Optimum Installation - Figure 1

The optimum installation is illustrated in Figure 1.

1. Area above refrigerator blocked (baffled) off to prevent trapping of hot air above the refrigerator. 2. 0 -1/4 inch clearance at the top of the refrigerator.
3. Exhaust vent centered directly over refrigerator’s condenser. 4. 0 - 1 inch at rear of the refrigerator. 5. 0 inch clearance at bottom of refrigerator.

Absorber (source of rejected heat)

Exhaust vent opening centered over condenser (front to rear of vehicle)

Norcold 442 — Optimum Installation - Figure 1 diagram (page 6)
Fig. 5 · Optimum Installation - Figure 1

Exhaust Vent Centered - Figure 2

Figure 2 further illustrates the requirement to center the exhaust vent opening over the condenser of the refrigerator.

Alternate Construction Requirements Figure 3

Norcold 442 — Alternate Construction Requirements Figure 3 diagram (page 6)
Fig. 6 · Alternate Construction Requirements Figure 3

1. Exhaust vent opening is inboard in relation to the rear of the refrigerator. 2. Baffles added to the top of the refrigerator to assist in directing air flow out the exhaust vent. 3. 0-1/4 inch clearance at the top of the refrigerator. 4. Angle between baffles and rear top edge of the refrigerator not to exceed 45 degrees. 5. Deflectors added at rear in strategic locations adjacent to the cooling units condenser and ab- sorber coils to reduce clearance to 0 to 1 inch.

Air flow path · Condenser · Absorber

Page 7 of the Norcold 442 user manual — Top and Side Wall Clearance-All Models Figure 6
Page 7 · click to enlarge
Page 7
Norcold 442 — Ventilation Requirement diagram (page 7)
Fig. 7 · Ventilation Requirement

Side Wall Clearance - Figure 4

1. Figure 4 illustrates the requirement to minimize the clearance at the sides of the refrigerator. The clearance is not to exceed 1/2 inch. Side clearances in excess of 1/2 inch must be either filled with Fiberglas batting or blocked with paneling, etc.

Upper Side Wall Exhaust Vent For Mod- els 452, 453, 442, and 443 ONLY Figure 5

Norcold 442 — Side Wall Clearance - Figure 4 diagram (page 7)
Fig. 8 · Side Wall Clearance - Figure 4

1. Area above refrigerator blocked (baffled) off to prevent trapping of hot air above the refrigera- tor. 2. 0 - 1/4 inch clearance at the top of the refrig- erator. 3. Upper Side vent Location. Floor level to top of opening. 38 1/8" for models 442 & 443. 50 1/2" for models 452 & 453. See Table 1 for vent dimensions, 4. 0 - 1 inch clearance at the rear of the refrigera- tor. (See Figure 3 when clearance exceeds 1 inch). 5. Intake (lower) vent installed flush with the sur- face on which the refrigerator is mounted. 6. O inch clearance at bottom of refrigerator.

Norcold 442 — Side Wall Clearance - Figure 4 diagram (page 7)
Fig. 9 · Side Wall Clearance - Figure 4

Top and Side Wall Clearance-All Models Figure 6

1. Top baffle fills the total area above the refrigerator an is properly aligned with the side wall construction. 2. 0 - 1/2 inch at the sides of the refrigerator.
Page 8 of the Norcold 442 user manual — TABLE 2 REFRIGERATOR CUT-OUT OPENINGS (INCHES)
Page 8 · click to enlarge
Page 8

INSTALLATION INSTRUCTIONS

Certification and Code Requirements

Combustion Seals

The refrigerators described herein are certified un- der the latest edition of ANSI Z21.19 Standards by the American Gas Association (A.G.A.) for installa- tion in mobile home or recreational vehicle and ap- proval by the Canadian Gas Association (CGA).

Combustion seals (foam strips) are attached to the back surface of the refrigerator’s mounting flanges. These seals isolate the products of combustion from the vehicle’s living space. The seals must be con- tinuous between the wall and the mounting flanges to assure a complete combustion seal. When installing or removing the refrigerator, insure that the seals are not missing or damaged.

Installation must be made in accordance with these standards and with the installation instructions pro- vided in this manual for the Norcold factory warranty to be in effect.

Installation must conform with local codes, or in the absence of local codes, with the following standards as applicable:

Lower Flange Installation

The lower mounting flange and mounting screws are located in a clear plastic bag positioned in the coils at the rear of the refrigerator. After removing the plastic bag, slide the refrigerator partially into the en- closure and attach the lower mounting flange. Install the lower mounting flange by maneuvering it under the bottom control cover and secure with the screws provided. Refer to Figure 7. Do not omit installa- tion of the lower mounting flange. This flange is part of the combustion seal.

In the United States:

a. National Fuel Gas Code, ANSI Z223.1. b. Manufactured Home Construction and Safety

Standard, Title 24 CFR, Part 23-80. c. Standard for Recreational Vehicles,ANSI A119.2, latest edition. When an external electrical energy is utilized, the refrigerator must be electrically grounded in accord- ance with local codes, or in the absence of local codes, the National electrical Code, ANSI/NFPA 70.

In Canada:

a. Current CGA B149.1 and B149.2 installation

code for Propane Appliances and Equipment.. b. Current CSA Z240.4.2 installation code for Pro-

pane Appliances and Equipment in Recrea- tional Vehicles. c. Current CSA Z240.6.2/C22.2 No. 148 Electrical

Requirement for Recreational Vehicles. When installed, the appliance must be electrically grounded in accordance with the current Canadian Electrical Code C22.2 Parts 1 and 2.

Cut-Out Dimensions

The refrigerators certified for built installation and requires cut-out dimensions as indicated in Table 2 below.

TABLE 2 REFRIGERATOR CUT-OUT OPENINGS (INCHES)

Securing the Refrigerator

Model 462, 463 482, 483 452,453 442,443

Height 52 7/8 59 7/8 43 1/4 30 7/8

Width 23 1/2 23 1/2 23 1/2 23 1/2

Secure the refrigerator with screws through the mounting flange holes at the front of the refrigerator and the holes at floor level at the rear of the refrig- erator. Screw covers are provided to cover the front mounting flange holes.

24

Depth

Page 9 of the Norcold 442 user manual — 12 Volt DC Connection
Page 9 · click to enlarge
Page 9

Gas Connection

Norcold 442 — Gas Connection diagram (page 9)
Fig. 10 · Gas Connection

The refrigerators are designed to operate on pro- pane gas at a supply pressure of 11 inches water column. A pressure regulator is required between the refrigerator and the main gas tank. Do not connect the refrigerator directly to the main propane tank without a pressure regulator. Use supply piping and fittings that comply with local, state, and national codes governing type and size. These components should also comply with NFPA 501C. Flexible metal connectors must comply with the current CAN 1-6.10 Standard. To prevent gas pressure loss to the refrigerator, the propane should be supplies by a 3/8 inch diameter copper piping. The gas supply piping is connected to the refrigerator by means of 3/8 inch SAE (UNF 5/8 - 18) male flare fitting. Route the gas supply piping to limit vibration and abrasion. The gas supply piping should enter the re- frigerator enclosure near the gas connection at the rear of the refrigerator. The hole through which the gas piping enters should be of sufficient size (ap- proximately 1/2 inch diameter) to provide adequate clearance for the piping. Once the gas piping is in place, apply a sealant around the piping at its point of entry to minimize abrasion and vibration, and to serve as a barrier to external moisture.

Figure 9 Rear View

120 Volt AC Connection

WARNING: The refrigerators are designed to operate on a 120 volt, 60 Hertz grounded AC circuit. The refrigerator’s AC power cord is equipped with a three-prong grounding plug which must mate with a three-prong grounded receptacle to protect against possible electrical shock hazards. Operating the refrigerator without proper ground can cause property damage, se- vere personal injury, or death. It is the in- staller’s responsibility and obligation to provide a properly grounded electrical cir- cuit to the refrigerator accordance with lo- cal codes, or in the absence of local codes, the National Electrical Code, ANSI/NFPA 70. Do not cut or remove the round grounding prong from the refrigera- tor’s AC power cord. Do not use a two prong adapter or an extension cord.

Norcold 442 — 120 Volt AC Connection diagram (page 9)
Fig. 11 · 120 Volt AC Connection

The free length of the refrigerator’s AC power cord is 24 inches. It is recommended that the three-prong grounded receptacle be located to the left side of the refrigerator (viewed from rear) and approximately 12 inches from the floor (see Figure 9 above). The AC power cord must be routed so as not to contact the refrigerator’s burner, flue pipe, or any other compo- nent which could damage the cord insulation.

The gas supply is connected to the refrigerator at the inlet to the manual gas valve located at the bot- tom rear of the refrigerator. Access to this area is obtained through the vehicle’s lower vent door. Care must be taken when connecting the gas piping to the refrigerator to insure the fittings are secure.

12 Volt DC Connection

A 12 volt DC supply is required to maintain the flame ignition circuit in the gas mode and for 3-Way models, to provide power for the DC heater. The DC

Turn

Page 10 of the Norcold 442 user manual — Chassis Bonding Connection
Page 10 · click to enlarge
Page 10

supply connects to the terminal block at the rear of the refrigerator (See Figure 9 on page 8). The 12 volt DC should enter the refrigerator’s enclosure near the refrigerator’s terminal block. The 12 volt DC connects at (2) one quarter inch quick connects. The positive DC input lead connects to terminal marked (+), and the DC ground input lead connects to terminal marked (-).

tional Electric Code (ANSI/NFPA No. 70, Art. 551). When this conductor is used to bond the non-current carrying metal parts of the refrigerator, a No. 10-32 bonding terminal is provided to make the connection. (See Figure 10 ).

The distance the current travels from the battery to the refrigerator dictates the wire size. Undersized wire can result in a voltage drop, which will affect the wattage output of the DC heater and result in re- duced refrigerator performance. Norcold recommends the installation of a fuse in the supply wiring between the battery and the refrigerator. For optimum protec- tion, install the fuse as close to the battery as possi- ble.

Hypot Test

A Dielectric Strength test (hypot) has been con- ducted at the factory; this refrigerator does not re- quire an additional test. If hypot tests are conducted on the vehicle’s 12 volt circuit, the 12 volts must be disconnected from the refrigerator to protect the flame ignition circuit.

Testing the Vehicle’s Gas Supply Piping

TABLE 3 12 VOLT SUPPLY WIRING AND FUSE SIZE

When installation of the refrigerator is complete, the propane gas supply piping must be inspected and tested for leaks from the refrigerator to the main gas supply tank. Use a leak detection solution. Do not test for leaks with an open flame.

482, 462 452, 442483, 463453, 443 min. wire sizemax. fuse sizemin. wire sizemax. fuse sizeMin. wire sizemax. fuse size 0 - 20’18 AWG6 Amp10 AWG30 Amp12 AWG20 Amp over 20’18 AWG6 Amp8 AWG40 Amp10 AWG30 Amp

If compressed air is used for leak testing, the gauge pressure must not exceed 1/2 pound per square inch (14 inches water column).

The appliance and its individual shut-off valve (Fig- ure 11 on page 10) must be disconnected from the gas supply system during any pressure testing of that system at test pressures greater than 1/2 psig (14 inches water column).

The appliance must be isolated from the gas supply system by closing its individual manual shut-off valve (Figure 11 on page 10) during any pressure testing of that system at test pressure equal to or less than 1/2 psig (14 inches water column). Check the gas pressure to the refrigerator without other gas appliances operating. The pressure should not exceed 11 inches water column. With other appli- ances operating the pressure should not be less than 10.5 inches water column.

If a wire size is installed which is larger than the minimum size indicated the table above, it must be fused in accordance with the R.V.I.A. A119.2 stand- ard or local governing codes.

Chassis Bonding Connection

A No. 8 AWG copper conductor is commonly used to meet the chassis bonding requirements of the Na-

Page 11 of the Norcold 442 user manual — TABLE 4 PANEL DIMENSIONS
Page 11 · click to enlarge
Page 11

INSTRUCTIONS

1. Prepare panel by cutting to size indicated in accompanying chart. (See TABLE 4) 2. Remove handle assembly (A) by removing four screws (B). (See Figure 12) 3. Slide panel into frame slots. 4. Replace the handle assembly.

Check Out - Flame Failure Safety Device

Before placing the refrigerator into operation, the gas safety device must be tested (see Operating In- structions on page 13). The purpose of the gas safety device is to prevent the escape of unburned gas from the burner if the burner flame is extin- guished. Once a flame is established, close the man- ual shut-off valve of the refrigerator. The flame will extinguish and ignition spark will continue. Wait a minimum of four (4) minutes and re-open the manual shut-off valve. The burner flame will not re-establish, indicating the gas safety control is functional.

Instructions for Reversing Door Swing

Your refrigerator is equipped with convertible door hinges. The hinging of the doors can be changed to the opposite side anytime you wish.

TOOLS REQUIRED

Phillips Screwdriver - Size #2 Two Slotted Screwdrivers

REMOVING THE DOORS

Door Panel Installation

1. Remove all items of food, juices, etc., from the doors. Remove the juice rack and storage bins. Close both doors before removing hinge pins. 2. Remove the top hinge pin using one of the slotted screwdrivers. Remove the center hinge pin (both pieces) using the two slotted screwdrivers; one on each end of the pin. Lastly, remove the bottom hinge pin. Be sure to save the pins for reassembly later. (See Figure 19)

The Norcold refrigerator doors provide slots for in- serting decorative panels. Installation of the panels is accomplished by removing the handle assembly, in- serting the decorative panel, and re-inserting the handle assembly. This procedure applies to both doors. (See Figure 12)

The frame slots are designed to accept panel thick- ness up to 3/16" maximum.

TABLE 4 PANEL DIMENSIONS

482, 483 Upper Door 19 11/16" x 16"19 11/16" x 16" Lower Door 19 11/16" x 32 1/4" 1911/16" x 39 1/4"
452, 453 Door Panel19 11/16" x 27 1/4" 1911/16" x 39 1/4"
3. Remove the upper door by opening the door slightly and pulling the bottom of the door away from the refrigerator. Allow enough room to slide the door down off of the upper hinge pin shoulder. (See Figure 13)
Page 12 of the Norcold 442 user manual — REMOVING AND RELOCATING THE HINGE BRACKETS
Page 12 · click to enlarge
Page 12

4 Remove the lower door by opening it slightly and pulling the top of the door away from the refrigerator. Allow enough room so the door can be lifted up and off of the bottom hinge pin shoulder (See Figure 18). Be sure to save the hinge plates along with the spacer used in the middle hinge bracket, for reassembly later. (See Figures 19A, 19B, and 19C)

RELOCATING THE TRAVEL LATCHES

8. Remove both travel latches by taking out the two screws holding each to the refrigerator. Use the #2 Phillips screwdriver. Remove the two screws from each of the corresponding holes on the opposite side of the refrigerator. Relocate them in the two holes just exposed by the removal of the latches. Attach the latch in the new position so the tab points towards the opposite side of the refrigerator. Do not tighten screws completely. (See Figure 16)

REMOVING AND RELOCATING THE HINGE BRACKETS

5. Remove the middle hinge bracket by using the #2 Phillips screwdriver and taking out the three screws holding it in place. Next, remove the three screws on the opposite side corresponding to the center hinge location. Relocate them in the holes just exposed by the removal of the hinge bracket. Attach the hinge bracket to the refrigerator on the opposite side. Do not tighten screws completely. (See Figure 15)
9. Turn the door over so that the end previously at the bottom is now at the top. Relocate the bottom of the door on the bottom hinge pin shoulder. Close door and align holes in top hinge brackets. The magnetic gasket will hold the door in place. Before reinstalling the top door, check to insure that the spacer is in place. (See Figures 17 and 19C)
6. Remove the top hinge bracket and reposition it in the opposite bottom corner. Use the same technique as outlined in Step #5. 7. Remove the bottom hinge bracket and reposition it in the opposite top corner. Use the same technique as outlined in Step #5.
10. Reposition the upper door in a similar manner as described in Step #9, except the top of the door must be engaged into the hinge pin shoulder before setting the door in place. (See Figure 18) 11. Starting at the top, replace the hinge pins using the slotted screwdrivers. Tighten all screws.
Page 13 of the Norcold 442 user manual — ALIGNMENT OF THE DOORS
Page 13 · click to enlarge
Page 13
Norcold 442 — Installation Instructions diagram (page 13)
Fig. 12 · Installation Instructions
Norcold 442 — Installation Instructions diagram (page 13)
Fig. 13 · Installation Instructions

A: Top Hinge B: Bottom Hinge

Norcold 442 — Installation Instructions diagram (page 13)
Fig. 14 · Installation Instructions

C: Middle Hinge D: Middle Hinge

Figure 18 Figure 19

ALIGNMENT OF THE DOORS

12. Align the upper door with the lower so that there is a parallel gap between the doors and around the frame. Adjust the doors to the cabi- net so the gaskets seal but do not bind. Tighten the screws holding the hinge brackets in place. 13. Door Seal: The door seal can be checked by closing the door on a 1" x 6" strip of paper. A slight drag should be noticed when the paper is pulled out from between the gasket and the cabinet. Repeat the process around all four sides of the door. If the door does not seal properly, readjust the hinge brackets. 14. Position the travel latches so that they secure the doors when closed but does not prevent the doors from closing properly. Tighten the two screws in each travel latch. 15. Replace the juice rack and storage bins into the door. Make sure that the milk bins (wider storage bins) are installed in the lowest door position.

Page 14 of the Norcold 442 user manual — Start-Up Instructions: AC Electric Operation
Page 14 · click to enlarge
Page 14

Lighting and Start Up Procedures

WARNING:

DO NOT HOLD GAS VALVE (D) IN MORE THAN 30 SECONDS. IF FLAME IS NOT INDICATED WITHIN THIS TIME, TURN GAS TO OFF, WAIT 2 MINUTES AND RETRY. CONTINUING TO HOLD GAS VALVE IN WILL CAUSE GAS BUILD-UP IN THE BURNER AREA AND CAN RESULT IN AN EXPLOSION WHICH CAN CAUSE PERSONAL INJURY OR DEATH.

2-Way and 3-Way Models

Lighting Instructions: Gas Operation

(D) clockwise so that "ELEC" is visible on the knob. Upon release, note that the knob moves toward you, indicating that the control is locked into electric operation.

1. Make certain that 12 Volts DC is available to the refrigerator and divider switch is in NOR- MAL position. 2. Turn on gas supply at the tank. 3. Set thermostat control (C) to COLDEST setting. 4. Set ignitor switch (A) to "ON" position. The tog- gle light (A) located on the switch will illuminate if 12 volts DC is present. 5. Push and rotate the "ELEC-OFF-GAS" control (D) counter-clockwise so that "GAS" is visible on the knob. Push the control knob (D) in and hold until the flame indicator (B) illuminates (continuous glow). Continue to hold approxi- mately 5 seconds, then release. The flame indi- cator (B) will remain on. If not repeat this step. NOTE: In normal use the flame should ignite

Start-Up Instructions: DC Electric Operation - 3-Way models

1. Make certain that 12 Volts DC is available to the refrigerator, divider switch is in NOR- MAL position, and "GAS IGNITOR" switch (A) is "OFF". 2. Set thermostat control (C) to desired setting. 3. Set "AC-STDBY-DC" switch (E) to "DC" posi- tion. 4. Set ignitor switch (A) to "OFF" position. 5. Push and rotate the "ELEC-OFF-GAS" control (D) clockwise so that "ELEC" is visible on the knob. Upon release, note that the knob moves toward you, indicating that the control is locked into electric operation.

within 10 seconds. On initial refrigerator start-up, it may take longer than 10 sec- onds to allow air to be purged from the gas line, as indicated by the flame indica- tor (B) failing to illuminate. Do not hold gas control valve (D) in more than 30 seconds. See WARNING above. 6. Move thermostat control (C) to desired setting 7. The ignitor switch (A) should be left in the "ON" position during gas operation. If the switch is turned off, the refrigerator will cycle normally. However, in case of flame blowout, the relighter does not function.

Operation Shut-Down: All Modes

1. Set ignitor switch (A) to "OFF" position. 2. Push and turn "ELEC-OFF-GAS" control (D) to "OFF". 3. For longer periods of shut-down, set NORMALSTORAGE-HUMIDITY switch to STORAGE.

Operation Note: Use the "ELEC-OFF-GAS" control (C) to shut off all cooling operation (both Gas and Electric). The "GAS IGNITOR" switch and the "NOR- MAL-STORAGE-HUMIDITY" switch must be shut off independently. The "STDBY" position of the "AC- STDBY-DC" switch (E) can be used to temporarily shut off AC or DC operation.

Start-Up Instructions: AC Electric Operation

1. Make certain that 120 Volts AC and 12 Volts DC are available to the refrigerator and divider switch is in NORMAL position. 2. Set thermostat control (C) to desired setting. 3. Set ignitor switch (A) to "OFF" position. 4. Push and rotate the "ELEC-OFF-GAS" control
Norcold 442 — Start-Up Instructions: AC Electric Operation diagram (page 14)
Fig. 15 · Start-Up Instructions: AC Electric Operation
Page 15 of the Norcold 442 user manual — !2 Volt DC Electric Operation
Page 15 · click to enlarge
Page 15

OPERATING AND USER INSTRUCTIONS

THIS APPLIANCE HAS BEEN DESIGNED FOR STORAGE OF FOODS, STORAGE OF FROZEN FOODS, AND MAKING ICE WHEN INSTALLED AS DIRECTED BY THIS MANUAL.

For AC electric, push and turn clockwise until the knob is pointing to"ELEC". Note, upon release the knob will move towards you, indicating that the oper- ating control is locked into the AC electric mode.

Safety Valve - During the gas ignition process, the safety valve knob must be held in until a flame is established at the burner.

Location of Controls

Norcold 442 — Location of Controls diagram (page 15)
Fig. 16 · Location of Controls

Figure 18 illustrates the location of the 400 Series refrigerator’s operating controls. All operating controls are conveniently located below the door.

The safety valve is designed so that any loss of flame will stop the gas flow to the burner. It is con- trolled by means of a thermocouple that is positioned in the flame. As long as a flame is detected by the thermocouple, the valve will remain open. Upon flame failure, the valve closes, shutting off the gas flow to the burner.

This switch is utilized on 3-Way models only. The switch selects either 120 volt AC or DC electric modes of operation. The center position of the switch is a "Stand-By" mode which will temporarily turn off the electric positions.

AC/DC Selector Switch 3-Way Models Only

Gas Operation

The gas burner is designed to operate on propane gas only. The gas control is equipped with an ignition relighter, offering the features of automatic re-ignition in case of flame blowout, positive flame sensing, and easier gas start-up. The ignition relighter is powered by 12 volts DC and is controlled by the ignitor switch located on the control panel. When the switch is in the "OFF" position, no ignition spark is present. When the switch is in the "ON" position, the relighter produces a rapid spark at the gas burner. The spark occurs at a rate of 1 to 2 times per second until a flame is present (Refer to "Lighting Instructions"). The spark continues until a flame is sensed or until the ignitor switch is turned off. When the flame is sensed, the relighter discontinues the spark and the flame indicator illuminates. The flame indicator lamp will cease to illuminate upon loss of burner flame. During gas operation, the current draw for the re-igni- tion system is very low, approximately 30 milliamps (.030 amps).

Gas On/Electric and Safety Valve

Operating Controls Function

The ignition switch is used for the Gas operation only. When the ignition switch is turned "ON", the switch will illuminate indicating that 12 volt DC is available and being supplied to the electronic ignition which generates ignition spark to the burner.

When a flame is established at the burner, the Flame Indicator Lamp will illuminate indicating the re- frigerator is operating on gas.

The thermostat controls all modes of operations, thereby eliminating the necessity of resetting each time a different power source is selected. Rotate the knob clockwise to make the refrigerator cabinet colder.

120 Volt AC Operation

While parked, the coach normally operates from a 120 volt AC source. The refrigerator can be very eas- ily switched to AC operation.

Gas ON/Electric and Safety Valve

!2 Volt DC Electric Operation

Gas ON/ELECTRIC allows the user to select an operating mode. For gas, push and turn the knob counter-clockwise until the knob is pointing to "GAS".

The refrigerator receives its DC power from the ve- hicle’s 12 volt system; either an auxiliary battery, a converter, or the engine battery. The 12 volt DC sys-

Show 4 more labels / short text on this page
AC/DC Selector Switch · Ignition Switch · Flame Indicator Lamp · Thermostat
Page 16 of the Norcold 442 user manual — Refrigerator Storage Volume
Page 16 · click to enlarge
Page 16

tem not only supplies power to the refrigerator, but to other DC components in the vehicle.

Remove the bulb from its bracket. Replace the bulb with a GE #214-2 bulb (Norcold part number 61628922), which can be purchased from most retail automotive centers. Re-install light cover. Reconnect the 12 volt DC.

DC electric operation is not as efficient as LP Gas or AC electric operation, and should therefore be used only when the other modes are unavailable (for example; while in transit - 4 to 6 hours). Reminder, before using the DC electric mode, the refrigerator must be cooled using either gas or electric.

Information Regarding Battery Drain

A 12 volt DC source is required for the gas mode and the DC electric mode of operations. For the gas operation, the DC power source supplies volt- age for the electronic ignition. The current draw is less than 30 milliamps. For models 482,3 and 462,3, if the HIGH HUMIDITY (MOISTURE RE- DUCTION HEATER) and the interior light were left on, the total DC current draw would be 900 mil- liamps (.9 amps). This indicates that the drain on the battery is very low and has little effect on "bat- tery run down" unless the battery is left connected for long periods of time without recharging.

High Humidity - Storage Switch Models 482,3 & 462,3 Only

The models 482,3 and 462,3 are equipped with a heater that prevents moisture from forming on the center divider between the freezer and the fresh food compartment doors. The heater is activated by turn- ing the NORMAL OPERATION-STORAGE-HIGH HUMIDITY switch to the HIGH HUMIDITY position. The switch should be left in the NORMAL OPERA- TION position unless condensation is observed in this area.

During AC electric operation there is no battery cur- rent drain, unless the interior light or moisture reduc- tion heater (HIGH HUMIDITY) is energized (models 482,3 and 462,3). For the DC electric operation, the DC power source supplies voltage for the cartridge heating element. For models 443 and 453, the DC electric operation draws approximately 9 amps at 12 volt DC. For mod- els 483 and 463, the DC electric operation draws ap- proximately 14 amps at 12 volt DC. If the battery charging means is lost during DC operation, for in- stance during short stops, the refrigerator could be switched to Gas, AC (if connected) or to the Standby switch position until the charging means is re-estab- lished.

When your RV is being stored for the winter, the High Humidity - Storage switch should be placed in the STORAGE (light off) position and ELEC-OFF- GAS control to OFF. This shuts off all DC power to the light and humidity heater and allows the refrigera- tor door to be left open for airing without chance of battery drain during storage (See "Information Re- garding Battery Drain")

The DC voltage should be checked while operating in the DC mode. The voltage at the refrigerator should never drop below 11.5 volts.

During periods when the refrigerator is not used (seasonal storage, etc.) the NORMAL OPERATION- STORAGE-HIGH HUMIDITY switch should be switched to STORAGE and the ELEC-OFF-GAS set at OFF. This shuts off all DC drain. The Ignitor switch must be turned off when not in use.

Interior Light-Models 482,3 & 462,3 Only

The interior light is located at the top of the fresh food compartment. The light will turn on when the fresh food compartment door is opened and off when the door is closed. Power to the light is activated when the NORMAL OPERATION-STORAGE-HIGH HUMIDITY switch is set to either NORMAL OPERA- TION or HIGH HUMIDITY positions.

Operation in Transit

To replace the light bulb, disconnect the 12 volt DC from the refrigerator from the rear of the refrigerator. Remove the light cover by sliding it towards the front to gain access to the bulb.

While the refrigerator should be level when the ve- hicle is stopped, performance during transit is not normally affected.

Refrigerator Storage Volume

Models 482,3 462,3 Storage Volume 7.5 cu. ft. 5.9 cu. ft

Models 442,3 452,3 Storage Volume 3.1 cu.ft. 4.3 cu. ft.

Page 17 of the Norcold 442 user manual — Defrosting and Cleaning the Refrigerator Interior
Page 17 · click to enlarge
Page 17

Leveling

erator interior. This will help to prolong the life of the gaskets.

Comfortable vehicle leveling is well within the re- frigerator’s operating requirements of 3 degrees off level side-to-side and 6 degrees off level front-to- back (looking at the front of the refrigerator). Con- tinued operation outside of these limits can result in irreparable damage to the cooling system.

Door Latch

The refrigerator’s built-in door latch prevents the door from flying open during transit. There are no chains or slides to remember to actuate when the vehicle starts moving (See Figure 25). Always close the door to the sealed position (audible clicks) to pre- vent cooling loss and heavy frost.

Freezer Compartment

This compartment is not designed for the quick freezing of food but designed to retain food in a fro- zen state. Foods purchased for storage in the freezer compartment should be frozen when purchased to reduce the load on the refrigerator system.

Important Notice:

Read and understand this notice before remov- ing this refrigerator, re-installing this refrigerator, or performing any maintenance on this refrigera- tor. Norcold will not accept responsibility for im- proper installation, adjustment, alteration, serv- ice, or maintenance performed by anyone other than a qualified dealer or a Norcold service cen- ter. Costs or related consequential problems re- sulting from improper installation, adjustments, alteration, service, or maintenance are the refrig- erator owner’s responsibility.

bottom freezer surface when making ice. Water will freeze more rapidly if the thermostat is at it’s coldest setting.

For models 482,3 and 462,3, the freezer shelf can be adjusted or removed to meet your storage needs.

Fresh Food Compartment

The fresh food compartment stores and cools food. For best cooling performance, air must be free to circulate within the fresh food compartment. Do not cover the shelves with paper, plastic, etc.

Refrigerator Maintenance

1. Leak test gas supply piping and fittings at least once a year. This procedure should only be performed by your dealer or a Norcold service center. These facilities are familiar with gas re- frigerators and propane gas systems. 2. Check the main line gas pressure periodically and adjust if necessary. The correct input gas pressure is 11 inches water column. It is rec- ommended that your dealer or a Norcold serv- ice center perform this task. 3. Clean the refrigerator’s burner and burner ori- fice. This procedure is required once a year minimum and should only be performed by your dealer or a Norcold service center. These facilities are familiar with gas refrigerators and propane gas systems. 4. Insure that the LP gas supply is Propane, not another fuel such as Butane or Butane mix- tures. 5. Periodically inspect the burner flame appear- ance during gas operation. See "Burner Flame Inspection on page 17. 6. Inspect the electrode assembly to insure it is secure to the burner bracket. 7. Inspect the flue of the refrigerator’s cooling sys- tem. This area must be free of foreign materi- als. Foreign materials observed in the flue indi- cate the burner requires cleaning. 8. Insure the area directly behind the refrigerator

To reduce frost formation on the cooling fins, cover liquids and moist foods, do not place hot foods in the compartment, and do not leave the door open longer than needed.

Allow the refrigerator to cool for 8 hours before loading foods. Loading a warm refrigerator with warm food increases the cool down period.

Defrosting and Cleaning the Refrigerator Interior

Your refrigerator is not frost free and will require pe- riodic defrosting. To defrost, turn the refrigerator off. Empty the freezer and the fresh food compartments. Placing a pan of hot water in the freezer will reduce the defrosting time. Leave the drip tray under the cooling fins. After frost has melted, empty the drip tray and clean the refrigerator.

Add a small quantity of mild dish detergent to luke- warm water and wash the interior of the refrigerator. Do not use abrasive cleansers; they can damage the interior surfaces of the refrigerator. Rinsing both compartments in a solution of baking soda and water (one table spoon of baking soda to one quart of water) will freshen the interiors and neutralize odors. Dry the interior with a soft cloth to remove excess moisture and to prevent water spots. Clean the door gaskets in the same manner as the refrig-

Page 18 of the Norcold 442 user manual — Burner Flame Inspection
Page 18 · click to enlarge
Page 18

is not being used for storage. Keep the refrig- erator area clear and free from combustible materials, gasoline, and other flammable va- pors and liquids. 9. Periodically inspect the ventilation system. The air passage from the bottom intake vent to the refrigerator coils and from the refrigerator coils through the upper exhaust vent must be unob- structed. 10. Inspect combustion seals (visual check without removing the refrigerator). Combustion seals are attached the back surfaces of the refrigera- tor’s mounting flanges and must be continuous between the wall and the mounting flanges to assure a complete combustion seal. 11. Periodically inspect door seals. See "Checking Door Seals" below.

ble burning appearance (Figure 22). If there is a con- stant yellow component observed or if the flame ap- pears erratic or unstable, switch the refrigerator to electric or turn the refrigerator "OFF" and contact

Norcold 442 — Operating and Users Instructions diagram (page 18)
Fig. 17 · Operating and Users Instructions

Checking Door Seals

To insure cooling efficiency and to prevent frost for- mation, the door gasket must seal completely.

your dealer or a Norcold service center.

To check for proper door seal, lay a strip of paper between the gasket and the refrigerator. Close the door and withdraw the paper. A frictional drag should be noticed. Repeat all around the door. If the paper does not have a noticeable drag, the gasket is not sealing. Contact your dealer or a Norcold service center for corrective procedures.

Refrigerator Removal and Replacement 1.

1. Turn off the gas at the main supply tank(s). 2. Turn the refrigerator off. 3. Turn the refrigerators manual shut-off to off. 4. Disconnect the refrigerator’s AC power cord from the wall receptacle. 5. Disconnect the 12 volt DC supply from the refrigerator’s terminal block. 6. Disconnect the LP gas supply line from the refrigerator. 7. Remove the mounting screws securing the refrigerator or to the enclosure. 8. Remove refrigerator form the enclosure.

Refrigerator Storage

When the refrigerator will not be in use for an ex- tended (seasonal) period of time, it is recommended that all power to the refrigerator be disconnected. Un- plug the refrigerator’s AC power cord from the wall receptacle and disconnect the 12 volt DC from the refrigerator’s terminal block located at the rear of the refrigerator. Clean the refrigerator interior and leave the door(s) open to keep the interior odor free. After the extended shut-down period, the burner, burner orifice, and flue must be inspected before igniting the burner flame. These areas must be free from dust, spider webs, or other obstructions which might re- strict the combustion system.

To Reinstall the Refrigerator:

1. Before reinstalling the refrigerator, inspect the areas behind the mounting flanges for damaged or missing seal strips (combustion seals). These seal strips serve as a combustion seal which isolates the living space of the vehicle form the refrigerator’s combustion system. 2. Reinstall the refrigerator by reversing the above procedures. 3. After reinstalling the refrigerator, check the gas fitting connections for leaks. Do not check for leaks with an open flame. Use an approved leak-detection solution.

Burner Flame Inspection

The efficiency of your refrigerator while operating in the gas mode is independent upon the correct burner flame. The burner flame provides energy to the re- frigerator’s cooling system.

The burner flame efficiency is a function of correct input gas supply pressure, air input, and burner and burner orifice cleanliness.

A visual check of the burner flame should be made regularly. The flame should be sharp blue with a sta-

Page 19 of the Norcold 442 user manual — SYMPTOM
Page 19 · click to enlarge
Page 19

Trouble Shooting

SYMPTOM

Refrigerator does not operate in AC Mode

* Mode Selection switch may be set to "OFF" or "GAS".

* Temperature Selector set too low.

* Refrigerator’s power cord may not be se- curely plugged in.

* Circuit breaker or fuse may be tripped or blown (AC power source to refrigera- tor).

* Wall outlet may be inoperative. (This can be checked by trying a different ap- pliance in the same outlet.)

* If unit fails to operate after the above items have been checked, unplug refrig- erator and contact a service center.

SYMPTOM

Refrigerator does not operate in Gas Mode

* Temperature Selector set too low.

* May be using gas other than LP gas. TURN OFF GAS AND CONTACT SERVICE CENTER.

* Gas not available to refrigerator (clogged gas supply line, empty tanks, etc.). Contact service center.

* Burner and orifice need cleaned.

* Spark ignitor needs replaced.

* If unit fails to operate after the above items have been checked, unplug the unit and contact a service center.

SYMPTOM

Poor Performance, Gas and Electric

* Incorrect power supply.

* Incorrect installation.

* Refrigerator off level.

* Unusually high ambient temperatures.

* Door opened frequently or for extended periods.

* Internal cabinet air circulation (wire shelves) blocked by food items, paper, or plastic.

* Hot foods placed in refrigerator.

* Refrigerator needs defrosting.

* Temperature selector set too low.

Possible Causes · Possible Causes · Possible Causes

Page 20 of the Norcold 442 user manual — SERVICE INFORMATION
Page 20 · click to enlarge
Page 20

FAILURE OF REFRIGERATION

* Available at most auto supply companies.

Failure of refrigeration does not necessarily indicate that the cooling system is defective. Other factors governing its operation must be checked.

20 Amp. Fuse Littelfuse SFE-20 15 Amp Fuse Littlefuse SFE-15 3 Amp. Fuse Littelfuse 1 AG-3 5 Amp. Fuse Buss AGC-5

If the refrigerator is operating on gas and a loss of cooling is noticed, switch the refrigerator to AC elec- tric operation. (See "Operating Instructions on page 13). If the refrigerator has been operating on electric, switch to gas operation. After the refrigerator has been switched from one power source to the other allow several hours to assure the refrigerator is cy- cling properly. This will help to determine if a compo- nent failure in the electric or gas control’s is causing the cooling fault. If no cooling is evident after eight hours (or overnight), you must contact your dealer or a Norcold service center to determine the cause of failure.

Description Model 4423 Model 452,3

Milk Bin 61579425 61579425 Dairy Keeper Lid 61580425 61580425 Ice Cube Tray 61630422 61630422 Crisper 61571325 Storage Bin 61564025 61564025 Outer Door Gasket 61640030 61568030 Freezer Door Gasket 61618730 61618730 Burner Orifice 61452122 61452122 Burner Gasket 61475122 61475122 Knob - Thermostat 61642322 61642322 Knob Selector 61641822 61641822 Fuse - DC Heater *61446022 *61446022 (3-Way only) (15 Amp) (15 Amp) Fuse - 12 Volt Control *61654622 *61654622 (3 Amp) (3 Amp) Fuse - AC *61611622 *61611622 (5 Amp) (5 Amp) Owner’s Manual 618484 618484

Replacement Parts

The following is a list of parts which can be re- placed by the owner and are obtainable from all Nor- cold Service Centers.

Le manuel de langue anglaise est disponsible sur demande, par l’lintermédiaire de vorte revendeur. N° de piéce: 618506.

Description Model 482,3 Model 462,3

Ice Cube Tray 61630422 61630422 Crisper 61571340 61571340 Juice Rack 61580525 61580525 Storage Bin 61564025 61564025 Milk Bin 61579425 61579425 Freezer Door Gasket 61567830 61567830 Lower Door Gasket 61568030 61567930 Cabinet Lamp 61628922** 61628922** Burner Orifice 61452222 61452222 Burner Gasket 61475122 61475122 Knob - Thermostat 61642322 61642322 Knob Selector 61641822 61641822 Fuse/DC Heater *61440522 *61440522 (3-Way Only) (20 Amp) (20 Amp) 3 Amp Fuse/12 Volt 61654622* 61654622* 5 Amp Fuse/AC 61611622* 61611622* Owner’s Manual 618484 618484

SERVICE INFORMATION

IF SERVICE OR PARTS ARE REQUIRED, CONTACT THE NEAREST NORCOLD SERVICE CENTER.

A NORCOLD SERVICE CENTER BOOK- LET HAS BEEN INCLUDED WITH THE RE- FRIGERATOR INFORMATION PACKET.

** GE PART NUMBER 214-2: DO NOT SUBSTITUTE.

Page 21 of the Norcold 442 user manual — Wiring Pictorials
Page 21 · click to enlarge
Page 21
Norcold 442 — Wiring Pictorials diagram (page 21)
Fig. 18 · Wiring Pictorials
Norcold 442 — Wiring Pictorials diagram (page 21)
Fig. 19 · Wiring Pictorials
Page 22 of the Norcold 442 user manual — Wiring Pictorials
Page 22 · click to enlarge
Page 22
Norcold 442 — Wiring Pictorials diagram (page 22)
Fig. 20 · Wiring Pictorials
Page 23 of the Norcold 442 user manual — NORCOLD SERVICE CENTER
Page 23 · click to enlarge
Page 23

LIMITED WARRANTY

NORCOLD SERVICE CENTER

P O BOX 4248 SIDNEY OH 45365-4248

This Limited Warranty is given by NORCOLD ("Company") to the original consumer-purchaser of any new refrigerating equipment ("Equipment") supplied by the Company, excluding glassware and electric light bulbs, and will be effective for a period of one year from date of original purchase. The Company warrants, provided that the Equipment shall at all times have been in possession of and used by the original consumer-pur- chaser, that:

A. The Company will provide free service and replacement of defective parts at no charge at all authorized

Norcold Service Centers for a period of one year from the date of original purchase. This Limited War- ranty covers labor costs incurred in removing and re-installing the refrigerator only when necessary to replace a defective part. The Company will pay inbound and outbound transportation costs of any defec- tive part, for a 1-year period commencing with date of purchase. The original consumer-purchaser must pay all expenses incurred in making the equipment available at one of the Norcold Service Centers. B. The following procedure must be followed by an original consumer-purchaser desiring to obtain per-

formance under the terms of this Limited Warranty. The refrigerator must be brought to any of the Norcold Service Centers and the original consumer-purchaser must present evidence (1) to identify the original consumer-purchaser: and (2) that the item claimed to be defective is still within the warranty coverage. If the original consumer-purchaser is unable to accomplish this task, written no- tice should be immediately directed to Norcold and advice will be promptly given concerning the manner in which warranty service may be obtained. Inability to physically bring the refrigerator to a Norcold Service Center will not void the warranty, but any additional costs thereby incurred are solely the responsibility of the original consumer-purchaser. C. The Company will not be liable under this Limited Warranty for any of the following:

(1) Defects which arise by reason of transit damage, misuse, neglect or accident. (2) Manufacturing defects found at the time of purchase which are not communicated to the Company

within 30 days. (3) Defects in glassware and electric light bulbs. (4) Defects arising from improper installation or adjustment of the Equipment. (5) The need for normal maintenance of this refrigerator, including the cleaning of the flue dilution assem-

bly and orifice, and the adjustment of the gas pressure regulator in the case of gas-electric models. (6) Defects arising from the improper use of parts or parts not manufactured or supplied by the Company

in the course of repairs or replacements to the Equipment. D. Employees and agents of the Company, and its authorized service representatives, have no authority to

vary the terms of the Limited Warranty, which applies only to Equipment purchased and installed in the United States of America and the Dominion of Canada. The Company reserves the right to make any improvements or changes in parts or models without notice to any original consumer-purchaser. E. The Company shall not be liable or in any way responsible for any loss or damage to person or property,

or lost profits or other similar loss or damage that may result or be claimed to have resulted from a defect in any parts of the Equipment covered by this Limited Warranty. Some states do not allow the exclusion or limitations of any incidental of consequential damages, so the above limitation or exclusion may not apply to you. F. ANY IMPLIED WARRANTY OF MERCHANTABLITY OR FITNESS FOR A PARTICULAR PURPOSE:

(1) APPLICABLE TO A PART OR PARTS OF THE REFRIGERATOR IS LIMITED TO A PERIOD OF

ONE YEAR FROM DATE OF PURCHASE. (2) SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS.

THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. G. This Warranty gives you specific legal rights, and you may also have other rights which vary from state

to state.

Ask about the Norcold 442

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Norcold 442

Be the first to ask — other owners or our team will answer.

Original document

Norcold 442 manual PDF

23 pages·389 KB·Refrigerator·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…