Instruction/ maintenance manual of the product 42ZCBB New Buck Corporation
Go to page of 22
New Buck Corporation Revised: November 2004 P.O. Box 69 8000 Hwy. 226 Sou th Spruce Pine, NC 28777 BUCK ST OVE MODEL 42ZCBB VENTLESS FIREBOX ENCLOSURE FOR GAS-FIRED DECORA TIVE TYPE UNVENTED ROOM HEA .
.
T ABLE OF CONTENTS Safety Information and Warnings ....................................................................................... 3 Installation .................................................................................................
2.
SAFETY INFORMA TION W ARNINGS IMPOR T ANT : READ THIS OWNER’S MANUAL CAREF ULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, INSTA LL, OPERATE, OR SERVICE THIS APPLIANCE (FIREBOX ENCLOSURE). Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
W ARNING DO NOT USE A BLOWER IN SER T , HEA T EXCHANGER INSER T , OR OTHER ACCESSO R Y NOT APPROVED FOR USE WITH THIS HEA TER. THIS HEA TER SHALL NOT BE INST ALLED IN A CONFINED SP ACE UNLESS PR OVISIONS ARE MADE FOR ADEQUA TE COMBUSTION AND VENTILA TION AIR.
INST ALLA TION Your New Buck Ventless Firebox Enclosure may be installed in Residentia l or *After-Market Manufactured Mobile Homes. This appliance may be installed in an *After Market Manufactured Mobile Home, where not prohibited by state or local codes.
FIREBOX AND FRAMING DIMENSIONS (ZC) & (FF) NOTE: SEE PAGE 10 IF AN OPTIONAL WOODEN FLUSH M OUNT MANTEL FRONT (FF) IS TO BE USED. Figure 2 GAS LINE 33-1/8" 18-15/16" 35-5/8" 36-5/8&q.
Figure 3 FIREBOX CLEARANCES The firebox may be placed dire ctly on a combustible floor, against a combustible wall at m arked clearances, or on a raised wooden platform. If the firebox is to b e installed on a raised woo den platform, the platform m ust be a continuous level surf ace.
FINISHING YOUR FIREBOX There is a wide variety of finishing material available for your firebox from formal wall treatments with m arble and mantels, to rustic wood paneling, stone or brick. IT IS IMPORTANT THAT THE BLACK FACE OF THE FIREBOX NOT BE COVERED WITH ANY TYPE OF COMBUSTIBLE MATE RIAL.
MANTEL PROFILES FOR VE NTLESS FIREBOX ENCLOSURE (UNIVERSAL BOX) ZERO CLEARANC E CABINET MUST BE FOLLOWED A 3” 3/4” 3 1/2” 4” B CANOPY STANDOFF COMBUSTIBLE MATERIALS 42ZCBB MANTEL CLEARANCES MANTEL WIDTH MANTEL HEIGHT (“ A ” inches ) (“ B ” inches above firebox op ening) 6.
D DATE REV. BY INST ALLA TION INSTRUC TIONS FOR MODEL 42ZCBB OPTIONAL WOODEN FLUSH MOUNT MANTEL FR ONT (FF) (KIT#P AKDM42ZCBBFF) “NOTE: Follow the framing instructions on page (s) 6 & 7. With the excep tion of the placement of the 42ZCBB in the framed opening .
INST ALLA TION I NSTRUCTI ONS FOR MODEL 42ZCBB OPTIONAL WOODEN SURROUND (WS) (KIT# P AKDM42ZCBB) CLEARANCES: 1. Sidewall Clearances: Clearances from the side of the firebox opening to any adjacent combustible wall should not be less than 7". See Figure 4 2.
REAR VIEW After assembling the WS you must insert the 42ZCBB. It is best to insert the 42ZCBB from the rear of the WS, this gives you more area to hold the 42ZCBB and reduces the risk of scratching the sur- face of the front area of the ba se (hearth) area.
This section is used for residential inst allation or mobile home installation. UNCONFINED SPACE: An unconfined space has a minimum air volume of 50 cubic feet for each 1,000 BTU/Hr (4.8m 3 per Kw) input rating of all appliances in the space (Cubic feet equals L ength x Width x Height of space).
3. Add the BTU/Hr of all fuel burning appliances in the space. Vent-Free Heater _________________________BTU/Hr. Gas Water Heater* _________________________BTU/Hr. Gas Furnace _________________________BTU/Hr. Vented Gas Heater _________________________BTU/Hr.
VENTILA TION AIR VENTILA TION AIR FROM INSIDE BUILDING This fresh air would come from an adjoining unconf ined space. When venting to an adjoining space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see Options 1 and 2, Figure 6).
Figure 7 Ventilation Air From Outdoors W ARNING THIS HEATER MUST HAVE FRESH AIR FOR PROPER OPERATION. IF NOT, POOR FUEL COMBUSTION COULD RESULT. READ THE FOLLOWING INSTRUCTIONS TO ENSURE PROPER FRESH AIR FOR THIS AND OTHER FUEL-BURNING APPLIANCES IN YOUR HOME.
OPTIONAL BLOWER INST ALLA TION The Model 42ZCBB has an optional MA ZCBB714 blower kit that can be purchased from your dealer. You will need to follow these steps and th e diagram below and the wiring diagram on page 15.
W ARNING: CHILDRE N AND ADULTS SHOU LD BE ALERTED OF HIGH SURFACE TEMPERATURE AND SHOULD STAT AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE APPLIANCE. W ARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIAL ON OR NEAR THE APPLIANCE.
REPLACEMENT P AR TS 1. PULL SCREEN (2) PER UNIT 2. SCREEN RODS (2) PER UNIT 3. REAR REFRACT OR Y AND SIDE REFRACT OR Y 2 PIECES PER UNIT 6. CANOPY 7. DOOR KIT (P AR T# MAZCBBDOORS) P AR TS MA Y BE OBT AINED THROUGH YOUR LOCAL NBC DEALER. IN ABSENCE OF A DEALER, PLEASE CONT ACT NEW BUCK CORPORA TION A T P .
NEW BUCK CORPORA TION We reserve the right to amend th ese specifications at any tim e without notice. The only warranty applicable is our standard wr itten warranty.
An important point after buying a device New Buck Corporation 42ZCBB (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought New Buck Corporation 42ZCBB yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data New Buck Corporation 42ZCBB - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, New Buck Corporation 42ZCBB you will learn all the available features of the product, as well as information on its operation. The information that you get New Buck Corporation 42ZCBB will certainly help you make a decision on the purchase.
If you already are a holder of New Buck Corporation 42ZCBB, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime New Buck Corporation 42ZCBB.
However, one of the most important roles played by the user manual is to help in solving problems with New Buck Corporation 42ZCBB. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device New Buck Corporation 42ZCBB along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center